Loading...
HomeMy WebLinkAboutS2022-0175 - MiscACOUSTICAL ENGINEERING ANALYSIS 1401 Santiago Dr. Newport Beach, CA 92660 March 29, 2024 YANCHAR DESIGN & CONSULTING GROUP 26741 Portola Parkway, Suite 1E, Foothill Ranch, CA 92610 Tel: 949.770.6601 Fax: 949.770.6575 E-mail: info@yanchardesign.com 1401 Santiago Dr. March 29, 2024 1.0 Introduction At the request of Matt White Custom Homes, Yanchar Design & Consulting Group has completed field measurements and an acoustical analysis of the pool equipment located at 1401 Santiago Dr., Newport Beach, CA. 2.0 Project Description The property is a single-family residence. The pool equipment is located approximately 3 feet from the property line to the west. The nearest property to the west is also a single-family residence. The properties are separated by a 6-foot CMU wall. The City of Newport Beach requires a sound test by an acoustical engineer is required to demonstrate that the noise level from the pool or spa pump is less than 55 dBA at the property line. NBMC10.26. 025. YANCHAR DESIGN & CONSULTING GROUP 2 1401 Santiago Dr. March 29, 2024 2.0 Field Measurements Measurements were made at the site on March 29, 2024 to determine the sound level of the pool equipment. The ambient noise level at the property was dominated by aircraft overflights and local construction activity. The sound level of the pool equipment measured at the southern property line was 54.5 dBA. Therefore, the equipment is in compliance with the requirements of the City of Newport Beach Municipal Code. A Soft dB Piccolo -II Integrating Sound Level Meter, Serial Number P0219050803 and CEL Instruments Model CEL-284/2 Calibrator, Serial Number 4/09023134, were used for the measurements. Respectfully submitted, Yanchar Design & Consulting Group Carl J. Yanchar President YANCHAR DESIGN & CONSULTING GROUP 3 1401 Santiago Dr. March 29, 2024 I IN 1 bf 4 �q d 3 LT d •f ' � N PROJECT VICINITY PROJECT SITE YANCHAR DESIGN & CONSULTING GROUP 4 Corvirz¢ous Insp ectinn &, Llateriols Testing SOUTHWEST �������ALA&��•►.►�.► Llspcc'lio❑ fi 1'csling. [n(-. 441 Commercial Way, La Habra, CA 90637-61(i8 (563)941-2990 (714j526-94g1 FAX (562)946-0026 CONCRETE: FIELD DATA ON TEST SPECIMENS ASTM C31, C138, C143, C172, C173, C231, C1064 MORTAR: SHOTCRETE: X CORES: ADDRESS: 1401 SANTIAGO DR, NEWPORT BCH JOB NAME: WATKINS ARCHITECT: CONTRACTOR: PINO LANDSCAPE GUNITE: JOB #: DATE: 10/20/2022 PERMIT #: S2022-0175 ISSUED BY: ENGINEER: BIEDENBACH SUB: BLUE PACIFIC SHOTCRETE LOCATION IN STRUCTURE: ( PANEL) BOTTOM OF POOL TRACT: PHASE: CONCRETE SUPPLIER: TYPE OF CEMENT: V SLUMP: 0.00 in. CONCRETE TEMP: 0 F DATE CAST: 09/22/2022 SPECIMENS MADE BY: RICHARD LUIZ LAB #: 215649 TESTING INFORMATION: PLANT: ADMIXTURE: WATER ADDED: 0 gal. MIXING TIME: 0 min. LOT #: MIX #: 35823-80120 TICKET #: 7246595 AIR TEMP: 0 F TIME CAST: 09:20 RECEIVED AT LAB: 09/29/20 22 SPECIFIED PSI @ 28 Days: 4500 CLIENT: RICHARD LUIZ SAMPLE IDENTIFICATION: 2320312 2320313 2320314 AGE DAYS: 28 28 DATE TEST: 10/20/2022 10/20/2022 28 1 22 SIZE (in.): Height X Diameter 7.000 X 3.500 7.000 X 3.500 7.000/000 X X 3.5.500 AREA (in.A2): 9.62 9.62 9 62 CRUSH LOAD (lbs.): 63830 64582 65023 COMPRESSIVE STRENGTH (psi.): 6640 6710 HEIGHT -DIAMETER RATIO: 6760 CORRECTION FACTOR: CORRECTED STRENGTH (psi.): BREAK TYPE: II C.T.M. USED: Forney% Forney96 IV Fome % Y REMARKS: ASTM C39, C174, C192, C470, C617, C42 COMPLIES: X DOES NOT COMPLY: FOR INFORMATION: THIS REPORT SHALL NOT BE REPRODUCED, EXCEPT IN FULL, WITHOUT THE APPROVAL OF SOUTHWEST INSPECTION AND TESTING, INC. SAMPLES CAST BY OTHERS: NOTICE:These test results are from samples cast by inspectors or technicians not employed by our frm. They were either delivered to our laboratory or picked up by our driver. We will accept no responsibility for the inspection made on the jobsite by the inspector, furthermore we do not take responsibility for any information on this report other than the strength as tested and reported. ASTM C39 BREAKS: I=CONE - II=CONE AND SPLIT RESPECTFULLY SUBMITTED SOUTHWEST INSPECTION AND TESTING ZAFAR AHP PRINCIPAL INEER III=COLUMNAR - IV=SHEAR - V=SIDE FRACTURES - VI=POINTED L9 '3Puimup u$�p punwdde uaswp 8uippng aqi a) adhi u0143adsuI ,df➢d323 133dSNJ IV133dS QOZB-6�9 (fi�o"i I itOO'�.3U�Ba0,LOGAivU'11JFJ^- -tuti7 f, 899Zfi li�'4aeafl �odMaN 189L45�w RPM Xo8 "0"d l ar+uQ �auafl a�n�� 004 = � , "� �+ ,Id wjRv<j (j jj4a Icj-o f',rr3��"Ap�aC HD �L u[ mL®catl�>_3K q® jenueW lonadsul jeuadS yoea8 DodmaN 10 03