HomeMy WebLinkAboutGB030139_Correction ListCounty of Orange PLANNING AND DEVELOPMENT SERVICES DEPARTMENT BUILDING PERMITS DIVISION Main Office 300 N. Flower Street Santa Ana, CA 92702-4048 Grading Plan Check Corrections Corrections shall be made on the tracings and three(3) new sets of plans shall be submitted. If you make changes to the plan other than or in addition to what Plan Check has requested, yellow highlight the changes on one set of the re-submitted plans. Return the original check print with corrected plans. Payment of a new plan check deposit may be required for all plans on which no action is taken by the applicant for a period of 180 days. Applications for which no permit is issued within 180 days following the date of submittal shall expire by limitation, and shall be discarded. Project Number:GB030139 Submittal Date:Aug 25, 2003 CBC Edition: 2000 Plan Check Date: 9/10/2003 10:23 AM Description:Grading for Custom Sfd Job Address 5 PELICANS DR NEWPORT COAST, CA Owner Address Bill Knight 2496 San miguel Dr Orange CA92687 Current - 1st Plan Check Architect of Record Eric Trabert Associates 20351 Irvine Ave. Suite One Santa Ana Heights CA92707 714-641-1505 714-641-1091 FAX Plan Checked By Javid Mohsenzadeh Javid.Mohsenzadeh@pdsd.ocgov.com 714-834-2662 Page 1 of 3 GB030139 GENERAL INFORMATION Please provide 24-hour notice to your plan checker, prior to obtaining the grading Permit.Return the original check print with corrected plans. Payment of a new plan check deposit may be required for all plans on which the applicant takes no action for a period of 180 days. Applications for which no permit is issued within 180 days following date of submittal shall expire by limitation, and shall be discarded. SUBMITTALS, FEES, BOND, INSURANCE AND ISSUANCE Provide three (3) complete sets of corrected plans. Provide minimum 40-scale plan for precise grading. The maximum size shall be 36" x 42". All sheets shall be uniform size. Plans will not be rechecked at the counter. Allow one week for recheck. Plan check and inspection deposit amounts will be calculated by the plan checker based on earthwork quantities or drainage improvements, whichever is greater. The engineer shall provide this information. Surety is required in the amount of $ _________. Surety may be posted in one of the following forms: Bond Certificate of Deposit Letter of Credit Cash or Cashier s Check Personal/Company checks cannot be accepted. County approved forms for the various types of surety are available upon request at the Grading Counter, Station 4, Room 122. Please note all signatures must be notarized. Provide verification of contractor's coverage for Workman's Compensation insurance. If owner is doing work and will not employ other workers, owner must sign exemption statement. Owner or authorized agent and/or contractor must sign the permit at the time of issuance. Authorized agent must have a notarized statement from the owner authorizing the agent to act on behalf of the owner. The permittee and the entity providing the surety must be the same i.e., owner, developer or contractor. Page 2 of 3 9/10/2003 10:23 AM GB030139 Grading Plan Check Corrections Sheet Comments General 1 B) Show site acreage and earthwork quantities on plans: 1.1 Site Acreage XXXXXX Acres 2 C) Each sheet of all plan sets must be stamped and signed by the Civil Engineer or Architect of Record for the project. 3 F) Show on Plans: 3.1 Grading Limits 3.2 Permit Limits 4 H) Show location of retaining walls on grading plan plus top of wall elevations, adjacent finished surface elevations, top of footing elevations, provide a cross section detail showing subdrain design, indicate drainage outlet for all retaining walls. Retaining walls are not a part of the grading permit. Submit for separate building permits; show connection of subdrain to storm drain. Note on plans. 5 S) Show on title sheet of plans name, address, and telephone number of: 5.1 Soil Engineer Drainage Instructions 6 M) Show limits of roof gutters and location of downspouts (if discharged onto A.C. paving or onto a finished grade, a P.C.C. splash block is required). Geotechnical 7 A) Obtain approval of soils and geology report by County Geotechnical staff. Reports have been forwarded for their review. Page 3 of 3 9/10/2003 10:23 AM = Indicates line item not Cleared.