HomeMy WebLinkAboutRW030956_Preliminary Review (1)Package:RW030956
Date:Oct 14, 2003
By:Ben Chin
Preliminary Plan Check Data
Applicant:Code Year:1998
Tenant:Email:
Basic Building:No FAX:
Use and Occupancy:Yes
Fire Sprinklers:No Compl. Date:
Job Address:5 PELICANS DR , NEWPORT COAST
Proposed Use of Building:retaining walls to max. 6 foot height
Building Data
Building Name:Knight sfd
Construction Type:Type V - N Stories:0
Total Bldg. Area:4054 Permitted T.I. Area:4054 Use & Occ:Y Fire Sprinklers:N Basic Bldg:N
Use Use Note Occupancy Load Factor Area Occ. Load Employees
Miscellaneous retain wall at sfd U-1 0 4054 0 0
Totals:4054 0
Preliminary Review Data
1. Building floor over 55 feet?No
2. Mechanical Vent System Required No
3. Sound Attentuation Required No
a. Fresh Air required for FAU No
b. Vent Requirements No
4. Wet Standpipes Required No
5. Dry Standpipes Required No
6. Paint Spray Booth No
7. Dust Collectng Equipment No
8. Flammable liquids No
9. Hazardous Materials No
10. Automobiles No
11. Exit Lighting:
a. Emergency Power Source No
12. Occupancy Separation None Required
13. Area Separation None Required
14. Corridor Enclosures None Required
15. Exterior Wall None Required
16. Exit Enclosures None Required
17. Exit Passages Way None Required
18. Exterior Stairway None Required
19. Shaft/Elevator Wall None Required
20. Floor/Roof None Required
21. Proscenium Walls None Required
22. Smoke Stop Partitions None Required
23. Storage Under Stairway None Required
24. Require Architect Wet Seal/Signature Yes
25. Engineer Wet Seal/Signature Yes
26. Show Handicapped Accessibility:
a. Waterclosets / Showers Yes
b. Path of Travel Yes
c. Car/Van Parking Stalls Yes
d. Building and Site Accessible Yes
Page 1
Package:RW030956
Date:Oct 14, 2003
By:Ben Chin
e. Drinking Fountain/Telephone Yes
f. ATM Yes
Routing Data
Route To Plumbing/Mechanical No
Route To Electrical No
Route To Commercial Yes
Route To OC Fire No
Route To OC Health No
Preliminary Reviewer Comment
SR-2call out type 2 PCC, see soil report;2001 CBC; F'm = 1.5ksi; type M or S mortar; call out subdrain
detail as 4" slotted sch 40 PVC, gravel filter, wrapped in filter fabric, show subdrain to approved
disposal point; call out special inspection for flexural concrete > 2.5ksi on spreadsheet format
on plan; call out min 90% backfill compaction; guardrail may be required at top of wall where wall
is adjacent to walking surfaces;
Page 2