Loading...
HomeMy WebLinkAboutXR2024-0906 - MiscCITY OF NEWPORT BEACH COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 100 Civic Center Drive I P.O. Box 1768 1 Newport Beach, CA 92658-8915 www.newportbeachca.gov 1 (949) 644-3200 SMOKE DETECTOR AND CARBON MONOXIDE SELF -CERTIFICATION (this certification is to be filled out by the permittee or homeowner) Project Address: 28 Permit Number: X V Z07y— Property Owner: Lap✓iG ✓Davis //tt Licensed Contractor: West M6✓ 4,1 /l Wl'ol T 1NG Lic #: a V 190 The State of California now requires that smoke and carbon monoxide detectors must be installed in all residential buildings California Residential Code (CRC) Section R314.1, CRC R315.2 states in part that existing dwellings be "retrofitted with smoke detectors and carbon monoxide detectors. CRC Section R314.3, CRC R315.3 defines required locations. Both boxes below must be checked. ® Carbon Monoxide Alarm: On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms or in each hallway outside of the rooms, and each level of the dwelling. Detectors are also required in bedrooms with gas fired appliances �J Smoke Alarms: Installed in each room used for sleeping purposes, outside each sleeping area, and on each level of the dwelling unit. Retrofitted detectors may be battery operated for buildings where no alterations are performed on the interior. Multiple -purpose alarms (carbon monoxide and smoke alarms) shall comply with all applicable standards and must be approved by the State Fire Marshall. The devices must be installed per manufacturer's specifications. I, the undersigned, hereby certify that I am the permittee or homeowner of the project. I further certify that smoke alarms and carbon monoxide alarms are present and tested to be functional in all the following locations: Signature:6� , i Date: !� - /3 - 1oa NOTE: This self -certification is only used for projects to the exterior of the structure where access to the interior of the dwelling by the City of Newport Beach Building Inspector is not achieved during the course of construction. Forms\SmokeDetectomndCarbonMonoxideSelfCert 08/12/16 ` CITY OF NEWPORT BEACH REPORT OF SPECIAL INSPECTION r inIonrn-r��s�. r__.__ i[Nor-c,, i ivrv. r ux set horizontal reoar aowels/Ketro-tit all thread rod DATE: 7/17/2023 OWNER: Sinner REGISTRATION No.: NB 5569 PROJECT ADDRESS: 222 Amethyst, Newport Beach CA ARCHITECT: ENGINEER: ESI/FME En ineerin PROJECT TYPE: Residential remodel BUILDING PERMIT: XR2023-0314 Observation and verification of the following work: Epoxy set horizontal rebar dowels (2) #4 horizontal rebar dowels installed T&B w/ min 6" embedment into existing exterior footing at new to existing footing. (2 locations/8 dowels total) See detail 14/SDI #4 horizontal rebar dowels installed w/ min 6" embedment dowels turned down 900 into existing foundation slab on grade to new concrete footing. (6 dowels total) See detail 13/SD1 #4 horizontal rebar dowels installed 16" oc both sides of plumbing/utility trench patch back areas w/ min 6" embedment into existing interior foundation slab on grade at plumbing/utility trench patch back areas. (38 dowels total) See details /SD1 (4) 5/8" o retro fit all thread rods installed for new HTT hold downs w/ min 14" embedment into existing exterior footing. (2 locations/4 total) See detail 15/SD1 5/8" o retro fit all thread rod anchor bolts installed with min 8" embedment into existing footings. (20 total/mist locations) No detail provided All work done in accordance with City of Newport Beach Building Department approved construction plans, ICC Evaluation Service Reports 4057, ASTM C172/C31,AC1 318-5.6, 5.8, 5.9, 5.10, and CBC sections1903/1704.4. 2304.9.5.1-2304.9.5.4, 2304.9.2 Holes were drilled to the required diameter and embedment depth, holes were blown out at 100 psi, brushed out, and then blown out again at 99 psi prior to epoxy application. All horizontal rebar dowels and epoxy set all thread rods were inserted into epoxy filled holes and rotated '/2 turn at time of installation. Simpson SET-3G epoxy was used. No problems noted at time of inspection. Steve Skeffington Deputy Inspector ICBO CERTIFICATIONS: 1030205-10, 20, 30, 40, 49, 50, 51, 55, 60, 89 ICC CERTIFICATIONS: 1030205-133, B5, B6, C5, C8, E5, M5, P5, R5, CB ACI FIELD TECHNICIAN GRADE 1: 0023995 19386 Highridge Way • Trabuco Canyon • CA 92679 • (949) 228-1261 • steve@coastdevelopment.net