HomeMy WebLinkAboutXC2024-0090 - Accessibility Hardship RequestCITY OF NEWPORT BEACH COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 100 Civic Center Drive I P.O. Box 1768 1 Newport Beach, CA 92658 www.newportbeachca.gov 1 (949) 644-3200 DOCUMENTATION OF UNREASONABLE HARDSHIP - $375.00 EI FINDING OF UNREASONABLE HARDSHIP FOR PROJECTS UNDER CASE NO.: $200,399* CBC 11B-202.4 — EXCEPTION: 8 (FILL OUT PAGES 1 & 2) H 2024- 0 FINDING OF UNREASONABLE HARDSHIP FOR PROJECTS OVER $200,399* CBC 11B-202.4 —EXCEPTION: 8 (FILL OUT PAGES 1 & 2) PROJECT INFORMATION: MUST BE ACCOMPANIED WITH RATIFICATION APPLICATION ** ❑ FINDING OF TECHNICAL INFEASIBILITY FOR PROJECTS PER CBC 11B-20Z3 - EXCEPTION: 2 (FILL OUT PAGES1, 2 & 3) A. JOB ADDRESS: 3501 COAST HWY E SUITE NO. B. PROPERTY OWNER: BLOKSGARD, GLICK & WEITZEL Address: 1891 TERRACE DR. City VENTURA State: CA Zip: 93001 Phone No. 805-340-2713 C. APPLICANT: JEFF BRANDON Position/Relationship: ARCHITECT Address: 3423 S. LA CIENEGA BLVD. City LOS ANGELES State: CA Zip 90016 Phone No.: 562-532-0465 Email: jbrandon@sees.com P/C, #: 2024-0455 Permit #: Use: M - RETAIL Stories: Verified by: Receipt #: DISTRIBUTION: ❑ Owner ❑ Petitioner ❑ P/C Eng ❑ Inspector ❑ Other An unreasonable hardship exists where the cost of providing an accessible entrance, path of travel, sanitary facilities, public phones, drinking fountains, etc. exceeds 20% of the cost of project without these features. The actual work of the project must comply with current code and an additional amount equal to at least 20% of the cost of the project must be spent to improve required accessibility features that are not in compliance with current code. In choosing which accessible elements to provide, priority should be given to those elements that will provide the greatest access, in the following order: 1) An accessible primary entrance; 2) An accessible route to the altered area; 3) At least one accessible restroom for each sex; 4) Accessible public telephones (when provided); 5) Accessible drinking fountains (when provided); 6) When possible, additional accessible elements such as additional parking, storage and alarms. To request an unreasonable hardship, complete the attached worksheet, and prepare a site and floor plan of the existing and proposed accessibility improvements. This information must be submitted to the Building Division in duplicate, prior to processing a permit application. One copy of the approval or denial will be returned to the applicant. For projects exceeding the valuation threshold of $200,399, a hardship approval can only be obtained through a ratification application and hardship application. * The $200,399 is based on $50,000 in 1981 dollars as of January 1, 2023. "Ratification form can be obtained at. https://www.newportbeachca.00v/ratificationform Forms\Hardship 01/1112024 Address: 3501 COAST HWY E P/C #: 2024-0455 1. Total Cost of Construction contemplated (not including disabled access work) $ 110,000 Identify the accessibility features, which will NOT be brought into compliance if the request is granted. Provide an estimate of the cost of compliance for each item. -O'Path of travel to entrance (ramps, walks) ..... ................. .................... ). $ s ese ❑ Path of travel to altered area(s)............................................................... $ _ ® Sanitary facilities (restrooms)(RFSTROOM.DOOR MANEUVERING. CLEAR;,,, $ 20,000 ® Parking P�.V AJM. ...rof` `.('`.!y...., ANCE ON PULL SIDE, 9-INCH TOE CLEARANCE)$ -- ........ ......... ............. 25,000 ❑ Drinking fountains) .' G¢" "y........................................................... $ ❑ Accessible phone(s)............................................................................... $ ❑ Accessible signage................................................................................. $ ---- ❑ Other....................................................................................................... $ Total cost of providing compliance:..... $ Identify the accessibility features and equivalent facilities, which will be provided or brought into compliance as required by Code. Provide an estimate of the cost of each item. a. PATH OF TRAVEL TO PRIMARY ENTRANCE, D-'[UT"Lb WAXVI✓(t $ 2,000 b. SANITARY FACILITY- RESTROOM TO PROVIDE FLOOR CLEARANCE AND $ 22,000 C. KNEE CLEARANCE AT ACCESSIBLE FIXTURES $ d. PATH OF TRAVEL TO Rrs7,eeo/✓i $ 10,000 e. $ f. $ Total: $ 34,000 2. Technically infeasibility - if applicable complete Page 3 of this application 3. Fill out this section if the path of travel from the disabled parking spaces to the tenant space is not accessible. List projects (tenant improvements, additions, remodels, etc.) performed within previous three years where no disabled access improvement was performed in conjunction with the project. State description, date, and cost. N/A The applicant understands that although the City may approve this request of unreasonable hardship' and the proposed equivalent access, the City reserves the right to require additional access compliance upon receiving a complaint of inadequate access at this location. 4. Jeff Brandon 06-12-2024 (Applicants Name orAuthorized Representative) (Date) 5. 06-12-2024 (Ap ants Signature) (Date FOR CITY USE ONLY Approved ❑Denied c - 4�: `�— h2f-B❑ifdmg-6liicral) -- (Date) Forms\Hardship 01/11/2024 2 Address: 3501 COAST HWY E p/C #: 2024-0455 TECHNICALLY INFEASIBLE. An alteration of a building or a facility that has little likelihood of being accomplished because the existing structural conditions require the removal or alteration of a load -bearing member that is an essential part of the structural frame, or because other existing physical or site constraints prohibit modification or addition of elements, spaces or features which are in full and strict compliance with the minimum requirements for new construction and which are necessary to provide accessibility. Describe why the nature of accessibility is technically infeasible: N/A Describe how equivalent facilitation will be provided: FormsWardship 01/11/2024 3 o® u LLI - z 0 z z O Q � N K LL a w U U z z _-F TOP OF WALKING SURFACE PARKING ONLY MINIMUM FINE $250 VAN ACCESSIBLE ACCESSIBLE PARKING SIGN REFLECTORIZED SIGNS TO BE PERMANENTLY POSTED WITH THE INTERNATIONAL SYMBOL OF ACCESSIBILITY IN WHITE ON A DARK BLUE BACKGROUND. SIGN TO BE LOCATED WITHIN THE PROJECTED PARKING SPACE WIDTH AND AT THE HEAD END OF PARKING SPACE. PORCELAIN STEEL WITH BEADED TEXT OR EQUIVALENT, ATTACH SIGN TO POST WITH 2 - 5/I6" CARRIAGE BOLTS. CUT BOLT TO 1/8" BEYOND NUT AND FLATTEN TO DETER REMOVAL 1/2" RADIUS - TYP. OCCURS ONLY AT VAN ACCESSIBLE STALLS E:F i SCALE: 2 _ L I. m PROPERTY LINE 1 2 CURB FAC m PUBLIC m PLANTESIDEWALK s m . CURB ' FACE n � 0 0 PARKING SPACE EXIST. PARKING SPACES TO REMAIN !EL LANDING MAX. SLOPE PROPERTY LINE LEASE LINE EXISTING BUILDING (NOT A PART) 'MEM • • • EXISTING SLOPE • i ARE NON- COMPLIANT • • • X (NEW TRUNATED DOMES W15 YR �� o PROVIDED BY • m 13 THE • N MANUFACTURER R OF DETECTABLE • • "' WARNING • p' • _ 0" PRODUCTS AND DIRECTIONAL SURFACES. ;GtS E%BG6 • .. F �> • CURB FACE • z L • �`� • • s 4 • • •� s PATCH AND F! _• REPAIR CONCRETE SIDEWALK. ,DDITION 105 S.F. CANDIES EXISTING ACCESSIBLE PATH OF TRAVEL WITH NO MORE THAN 5% SLOPE IN THE DIRECTION OF TRAVEL AND NO MORE THAN 2% P/(SE/�Zs/lPARATE w CROSS SLOPE REMOTE STORAGE Z PROPERT`) a SITE PLAN - proposed ada SCALE: 3/32" = V-0" ra Wcm 1wZ c Q y Y/ J a o d 0 ( n a a Z_ 0 M 3'-0"MIN. PLANTER W SIDEWALK Q z IQ 0 O r U b 3 - 4" SLOPE NO DETECTABLE WARNINGS EXISTS O Q m I a AT PATH OF TRAVEL FROM O o PARKING SPACE TO BUILDING m > � "INTERNATIONAL SYMBOL OF ACCESS" TO K 0 BE PAINTED TRAFFIC WHITE ON BLUE m cc cc BACKGROUND k t— w O SCALE: 32' " 1" fl ACCESSIBLE PARKING SYMBOL ,,._,,o,. 2 �a. EXIST. CURES II' - 0" EXIST. GUARDRAIL r N �j N 2 rn (3 Q EXISTING SEE'S CANDIES = v ¢< O� U LU w w0 MO m N RS I U CDN Q PLANTER W SIDEWALK Q z IQ 0 O r U b 3 - 4" SLOPE NO DETECTABLE WARNINGS EXISTS O Q m I a AT PATH OF TRAVEL FROM O o PARKING SPACE TO BUILDING m > � "INTERNATIONAL SYMBOL OF ACCESS" TO K 0 BE PAINTED TRAFFIC WHITE ON BLUE m cc cc BACKGROUND k t— w O SCALE: 32' " 1" fl ACCESSIBLE PARKING SYMBOL ,,._,,o,. 2 �a. EXIST. CURES II' - 0" EXIST. GUARDRAIL r N �j N 2 rn (3 Q EXISTING SEE'S CANDIES = v ¢< O� U LU w w0 MO m N RS I U CDN Q W_ d d Z CAI Q L1 O O O O O O O O EXISTING - EntryDoor SCALE: 1 1 /8" - 1 �_0. NEW DOOR TO WORK {�{ ARFEA W/ REQUIRED DOOR / III DOOR CLEARANCES Or- 4'—e" 5-0" / 1 1 F NEW PAIR ENTRY DOORS W/ REQUIRED DOOR CLEARANCES O O O O O O Lo -10 SCALE: PROPOSED - Entry Door 1/8„=1,_0„ 2 J 5'-0" CLEAR 3 - b" MIN 3 - 0" MIN. 2' 0' - 0" MIN. MIN. 2 EMPLOYEE RESTROOM PLAN „K � z z 'v of m E m 6e DIA. CLEAR SPACE m x SEE DETAIL FOR ACCESSIBLE J—_'�,MOUNTING 1 HEIGHTS F SCALE771 3 3/8" = 1'-0" EXISTING - Restroom SCALE: i 1/4" = 1'-0" • a I NEW 36" • - NEW RESTROOM WITH DOOR • / • REQUIRED CLEARANCES. I I SEE ENLARGED PLAN THIS SHEET. OFT \ / I E-:) • PROPOSED - Restroom SCALE: n 1/4" = 1'-0„ G dz �Q Z Ln a J 0. Pro a z ' o O O m N w m id DETECTABLE WARNING SURFACES SHALL BE DURABLE, SLIP -RESISTANT MATERIAL HAVING A SURFACE TEXTURE COMPOSED OF RAISED, TRUNCATED DOMES ALIGNED IN A SQUARE GRID PATTERN. TRUNCATED DOMES SHALL HAVE A BASE DIAMETER OF 0.9 INCH MIN. TO 1.4 0 3 INCHES MAX., A TOP DIAMETER OF 50 % MIN. OF THE BASE DIAMETER TO 65 % MAX. OF THE 0 BASE DIAMETER, AND A HEIGHT OF 0.2 INCHES. DOMES SHALL HAVE A W E CENTER -TO -CENTER SPACING OF 1.6 INCHES MIN. AND 2.4 INCHES MAX. AND A �. BASE -TO -BASE SPACING OF 0.65 INCHES MIN. MEASURED BETWEEN THE MOST ADJACENT DOMES ON THE SQUARE GRID. ONLY APPROVED D5A-AC DETECTABLE WARNING PRODUCTS Q TO BE USED WITH 5 YEAR WARRANTY `m i J C Or O LnLu fa. N z SCALE: PROPOSED -Entry Door Plan 2 oo , IM LV a 14„=11_0„ 0 .. J o 0 W a U Z COLOR: YELLOW AND APPROX. FS 33538 OF SAE AMS-STD-595A I— SCLJD GORE DOOR 2.3"-2.4" L 2.3'-2.411 11 DOOR B07iOM 0 5-`g 0.45"-0.41" 0..92" } Lo WI VINYL Q WEATHERSTRIP 0 2„ >j � 2 a Q E L FINISH PER LAN �U = 2 MAX. ~ < Q2 O-1 U uJ c4 Q SLOPE Qz wO � ° a CAULKING a ° ° a ° ° O O a a a CONT. CAULK BEAD M 1/4" EXP. JT. CONCRETE SLAB d SCALE: DOOR THRESHOLD 3 ico DETECTABLE WARNING DETAIL I N c>sz 6„_,,0„ 12CA1Eo o Q F.R.P. PANEL OVER WATER RESISTANT GYPSUM BOARD 3/I6" THK. STAINLESS STEEL FLANGE WITH SATIN FINISH MIN. 1 1/4" DIA.- MAX. 1 1/2" DIA. STAINLESS STEEL GRAB BAR BOBRICK 5-6106 3-1/4" DIA LAG BOLTS WITH 3" MIN. PENETRATION TO 4X BLOCKING SIMPSON A35, TYP GRAB BAR DETAIL SCALE: 3-0" S.S. GRAB BAR (START (o" OFF WALL) S.S. GRAB BAR (START 12" OFF WALL) GRAB BAR NOTES THE STRUCTURAL STRENGTH OF GRAB BARS, FASTENERS AND MOUNTING DEVICES SHALL MEET THE FOLOWING SPECIFICATIONS BENDING STRESS IN A GRAB BAR OR SEAT INDUCED BY THE MAXIMUM BENDING MOMENT FROM THE APPLICATION OF A 250 LB. POINT LOAD SHALL LESS THAN THE ALLOWABLE STRESS FOR THE MATERIAL OF THE GRAB BAR OR SEAT. 2, SHEAR STRESS INDUCED IN A GRAB BAR OR SEAT BY THE APPLICATION OF A 250 LB. POINT LOAD SHALL BE LESS THAN THE ALLOWABLE SHEAR STRESS FOR THE MATERIAL OF THE GRAB BAR OR SEAT, AND ITS MOUNTING BRACKET OR OTHER SUPPORT IS CONSIDERED TO BE FULLY RESTRAINED, THEN DIRECT AND TORSIONAL SHEAR STRESS SHALL NOT EXCEED THE ALLOWABLE SHEAR STRESS. 3, SHEAR FORCE INDUCED IN FASTENERS OR MOUNTING DEVICES FROM THE APPLICATION OF A 250 LB. POINT LOAD SHALL BE LESS THAN THE ALLOWABLE LATERAL LOAD OF EITHER THE FASTENER OR MOUNTING DEVICE OR THE SUPPORTING STRUCTURE, WHICHEVER HAS THE SMALLER ALLOWABLE LOAD. 4. TENSILE FORCE INDUCED IN A FASTENER BY A DIRECT TENSION FORCE OF A 250 LB. PONT LOAD, PLUS THE MAXIMUM MOMENT FROM THE APPLICATION OF A 250 LB. POINT LOAD, SHALL BE LESS THAN THE FASTENER AND SUPPORTING STRUCTURE. 5. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS. b. A GRAB BAR AND ANY WALL OR OTHER SURFACE ADJACENT TO IT SHALL BE FREE OF ANY SHARP OR ABRASIVE ELEMENTS. EDGES SHALL HAVE A MINIMUM RADIUS OF I/8". FLUSH LEVER �" MIN. LAVATORY MOUNTED ON .3" MAX. 8" MIN. DEPTH WIDE SIDE OF X 30" MIN. TOILET AREA WIDTH KNEE SPACE LL LL 24" MIN. _ CBC COMPLIANT Q a CLEARANCE z X F Q Z Z ILz a z F L� c' 4" MAX. PROJECTION FROM WALL PAPER TOWEL _ DSPNSR TOILET SEAT _ COVER DSPNSR SOAP DSPNSR O Lu MIN.\ —INSULATE HOT WATER d DRAINPIPES T" MIN PER THE CBC 115-606.5 REQUIREMENTS z F v SWITCHES THERMOSTAT FIRE ALARM GENERAL ACCESSIBLE PLUMBING NOTES A. 5. C. D. WATER CLOSET CONTROLS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC. HAND CONTROLS SHALL COMPLY WITH SECTION II5-305 EXCEPT THEY SHALL BE LOCATED 44 INCHES MAX. ABOVE THE FLOOR. FLUSH CONTROLS FOR FLUSHING OF WATER CLOSETS AND URINALS SHALL BE MOUNTED ON THE OPEN SIDE OF THE WATER CLOSET EXCEPT AMBULATORY ACCESSIBLE COMPARTMENTS COMPLYING WITH SECTION I15-b04.8.2 THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 LBS. FORCE. IN SELF CLOSING VALVES ARE USED, THEY SHALL REMAIN OPEN FOR AT LEAST 10 SECONDS. r L!�1 i W I Q Li N E. FAUCET CONTROLS AND OPERATING MECHANISM SHALL L /� / J Q NOT BE OF THE TYPE REQUIRING TIGHT GRASPING, W PINCHING OR TWISTING OF THE WRIST (OPERABLE WITH ONE z HAND SUCH AS LEVER OPERATED) AND AN OPERATING FORCE NOT EXCEEDING 5 POUNDS. o �aF. LAVATORIES SHALL BE INSULATED AT ALL EXPOSED DRAINS. PLUMBING UNES AND mi L CBC COMPLIANT TOILET SIGNAGE TACTILE BRAILLE SIGN DOOR 24X36 N Q HARDWARE MIRROR = J C7 Q =U lu I [-- E Q 0 N O w Q 13 O Q Q m £ Z LLI 0 0 co ACCESSIBLE MOUNTING HEIGHTS N cz � U SCALE: i m Lo CD