HomeMy WebLinkAboutXR2024-0923 - Alternative Material & MethodsagWP0�s7 CITY OF NEWPORT BEACH
O� 5
ter' COMMUNITY DEVELOPMENT DEPARTMENT
u yp T BUILDING DIVISION
100 Civic Center Drive I P.O. Box 1768 1 Newport Beach, CA 92658-8915
,�/FORS www. newoortbeachca.00v 1 (949) 644-3200
w — A
CASE NO.:
FOR STAFF USE ONLY
to
REQUEST FOR MODIFICATION TO PROVISIONS
OF TITLE 9 CODE) OR TITLE 16 CODE)
Plan Check#pLZO #of Stories
(FIRE (BUILDING
OF THE NEWPORT BEACH MUNICIPAL CODE
Occupancy Classificatio
(See Reverse for Basis for Approval) (Fee $306)
Use of Building # of Units
Project Status ,
❑ REQUEST FOR ALTERNATE MATERIAL
Construction Type
OR METHOD OF CONSTRUCTION
Verified by �.
(See Reverse for Basis for Approval) (Fee $306)
N0. of Items �.
Fee due
For above requests, complete Sections 1, 2 & 3
below by printing in ink or typing.
DISTRIBUTION:
❑ Owner qa Plan Check
Petitioner [] Inspector
Fire ❑ Other
71 JOB ADDRESS:
PETITIONER:
SITE ADDRESS: CDC54�44 MI
E Petitioner 3T! -EE�/ %- �-
Owner ' 1—
(P WonerWas a hftwrcrwgmeed
I NNN
Address 2-if:3
a
Atltlreas IOz
N NC�t Cr1 zi
Da R Lp lcGi3
Daytime Phone (7J44 �•—��L�.:7
Daytime Phone (F 144 —a — 2�GCJ
Email Led Zen
2 REQUEST: Submit plans if necessary to illustrate request. Additional sheets or data may be attached.
CIANO
GG
O
3 USTIFICATION/FINDINGS OF EQUIVALENCY:
CODE SECTIONS:
v
o
Petitioners
Signatur CA Professional Lic. # Date:'�-i•
FOR STAFF USE ONLY
DEPARTMENT ACTION: In accordance with: ❑ CBC 104.11/CFC 104.9 CBC 104.10/CFC 104.8
(Alternate materials & methods) (CBC Modification)
❑ Concurrence from Fire Code Official is required. ❑ Approved ❑ Disapproved ❑ Written Comments Attached
By: Date
Request (DOES) ( lessen any fire protection requirements.
Request (DOES) OES T) lessen the structural integrity
The Request is: Granted ❑ Denied (See reverse for appeal information)
❑ Granted (Ratification required)
Conditions of Approval:
Signaut'ce� —' Position CHIEF Rlfll T-,!NC, CERCPaif
Print Name
&CEIVED BY
>OMMUNITY
AWELOPMENT
4 2024
CITY OF
NEWPORT BEACH
APPEAL OF DIVISION ACTION TO THE BUILDING BOARD OF APPEALS (See Reverse)
(Signature, statement of owner or
applicant, statement repsons for appeal and
filing fees are required.)
CASHIER RECEIPT NUMBER: W — t/b 5 � `%—7-� `. ,{'Fomislmodif 08/21/23
KITCHEN
W
ZI
8'-9'CEILING
O z
J
m
J
1
0J' FalrS
,I 06) Rears
freads -ll"MIN.
9
4
3$
6
12 8 7811
A11 j j
I
l5
O
Up m
20
11
I 43
I 2 S I n
a �
I
LIVING ROOM
F.F. ELLEV.11V. 11.
I q
I , I W
El
39
I I _
N
I f --- ---- a ----- �
_ — _ _ — — I ry
14
A11
I 26'-3"
I
963W PROPMM LINE
1st FLOOR PLAN
Note: 1/4' o T-O"
1) Use 2x6 minimum stud wall construction for all exterior walls.
2) All exterior doors shall have a minimum 36 inch landing on each side of the door Landings or floors
at the required egress doors shall be not more than 1-1/2 inches lower than the top of the threshold.
3) All hallways, closets, atc, to have 8-0" minimum ceiling heights (unless noted otherwise)
4) Penetrations through roof or exterior wall assemblies by ducts, pipes, and/or other appurtenances
shall be made water tight (CPC 312.8)
❑ I 6'-5"
28
23 15 12
UTILITY RM
J7 E'.i° CEILING
❑r—�r—�
24 MIN
MASTER BATH
SCEILING
12
19
CLOSET
3-4°
C'Li71
0
NEI
z
a
�
e
itairs
IS) Risers ®7A6'
reads - 1 MIN.
m
t`
MIN.
Q
I
32 ICI 10 A6 32
I 3p•_p^
I
36.34' PROPERTY LINE
2ND FLOOR PLAN
Note: 1/4' = T-O"
1) Use 2x6 minimum stud wall construction for all exterior walls.
2) All exterior doors shall have a minimum 36 inch landing on each side of the door Landings or floors
at the required egress doors shall be not more than 1-1/2 inches lower than the top of the threshold.
3) All hallways, closets, etc, to have 647 minimum ceiling heights (unless noted otherwise)
4) Penetrations through roof or exterior wall assemblies by ducts, pipes, and/or other appurtenances
shall be made water tight (CPC 312.8)
WMa - -11
l U UL �,�t���l ,t � y
35
I
31_
W
II
ia Vermeer Saw
orI manner so as to
I I
I�
_` IIIIII�
EAST ELEVATION
SHEET METAL
SENDS
12 39.F
3 ROOF / RIDG
PITCH
1/4' =1'-O"
ROOFING MATERIAL
Berridge Tee -Panel 24 gauge steel closs'A' rated
standing seam metal roofing Color. Charcoal Grey
Reflectivity: 0.52/Emmisiv'ity 0.53/SRI:59
IGG Evaluation ESP-3486 ASTM E-1592
note: provide minimum underloyment one layer of GAF Versa Shielc
(ESR-2053)
25 2
12� 1 12
,
!
§)
!!
2
)
�
2
�\
)
\\