HomeMy WebLinkAboutX2021-3462 - SoilsENGINEERS + GEOLOGISTS + ENVIRONMENTAL SCIENTISTS June 18, 2024 J.N. 21-422 NICHOLSON CONSTRUCTION 1 Corporate Plaza, Suite 110 Newport Beach, California 92660 Attention: Ms. Nanci Glass Subject: Final Soils Report, Geotechnical Observations and Testing, Foundation Excavations, Slab Subgrades and Utility Trench Backfill, 225 Jasmine Avenue, Corona Del Mar Area, City of Newport Beach, California References: 1) Geotechnical Investigation, Proposed Single Family Residence, 225 Jasmine Avenue, Corona Del Mar Area, City of Newport Beach, California; report by Petra Geosciences, Inc., J.N. 21-422, dated November 10, 2021. 2) Geotechnical Report of Rough Grading, Proposed Single -Family Residence, 225 Jasmine Avenue, Corona Del Mar Area, City of Newport Beach, California; report by Petra Geosciences, Inc., J.N. 21-422, dated December 5, 2022. 3) Geotechnical Commentary on Construction of Northerly Property Line Retaining Wall, 225 Jasmine Avenue, Corona Del Mar Area, City of Newport Beach, California; report by Petra Geosciences, Inc., J.N. 21-422, dated March 15, 2024. Dear Ms. Glass: Petra Geosciences, Inc. (Petra) is submitting herewith a summary of our observations of foundation excavations for the site structures, and our observations and test results pertaining to slab subgrade soils, and placement and compaction of backfill within utility trenches located in landscape areas, and under proposed slabs within the subject site. Representatives from our firm performed on -call field density testing and field observations at the request of the project superintendent during post -grade operations. It should be noted that Petra was not contacted and therefore did not perform geotechnical observation of the foundation excavation for the wall along the northerly property line and as such, this item is not under the purview of this report. SUMMARY Foundation Excavation Observations Excavations of footing trenches for the residence and site structures were probed and observed to be excavated into engineered fill per the foundation plans and the recommendations presented in our reference Offices Strategically Positioned Throughout Southern California ORANGE COUNTY OFFICE 3186 Airway Avenue, Suite K, Costa Mesa, California 92626 T: 714,549.8921 F: 714.549.1438 For more information visit us online at w .oetra-inc.com NICHOLSON CONSTRUCTION June 18, 2024 225 Jasmine Avenue / Corona Del Mar J.N. 21-422 Page 2 reports. As noted earlier, Petra was not contacted and therefore did not perform geotechnical observation of the foundation excavation for the northerly property line wall and as such, this item is not under the purview of this report. Utility Trench Backfill 1. Backfill of interior and exterior trenches consisted of onsite soils placed above select sand bedding. The sand bedding placed above utility lines was jetted and varied from approximately 6 inches to 2 feet in depth. Backfill materials were moisture conditioned, as necessary, to achieve optimum or above optimum moisture conditions prior to and/or during placement, and then compacted in 6- to 8-inch lifts with a pneumatic tamper to a minimum relative compaction of 90 percent (based on ASTM D 1557). 2. Exterior trench backfill consisted of sewer, water, area drain, and a common (joint) trench containing electric, gas, telephone and data lines. The approximate maximum depth of soil backfill placed over bedding sand for the various trenches was approximately 3 feet in the sewer trench excavation. 3. Utility trench backfills, where probed and/or tested, are considered to have been placed in accordance with the recommendations presented in the referenced reports. Slab Subgrades Due to the amount of time that had elapsed since the completion of rough grading, and due to disturbance during construction activities, the surficial subgrade soils of the slabs were moisture conditioned to achieve optimum or above optimum moisture content and then compacted in -place to a minimum relative compaction of 90 percent of the applicable laboratory maximum dry density in general accordance with ASTM Test Method D 1557. These subgrade soils were tested prior to concrete placement and are considered acceptable from a geotechnical point of view. The subgrade soils were also pre -watered as per our recommendations (References). Field and Laboratory Testing 1. Field density tests results for trench backfills and slab subgrades are summarized in Table I, and approximate test locations are shown on the accompanying Density Test Location Map (Figure 1). Field density tests were taken with a Nuclear Gauge (ASTM D 6938). 2. Field density tests were taken at vertical intervals of 1 to 2 feet. 3. The laboratory maximum dry density and optimum moisture values for the most prominent onsite soils (Soil Type A) were determined according to Test Method ASTM D 1557 and are listed in Table II. CONCLUSIONS Footing trench excavations for the residence and site structures were observed to have been founded into engineered fill. In addition, where observed and tested, utility trench backfill and slab subgrade soils as discussed in this report were found to be in general compliance with our recommendations and the grading PETRA - SOLID ASA ROCK GEOSCIENCES"° NICHOLSON CONSTRUCTION June 18, 2024 225 Jasmine Avenue / Corona Del Mar J.N. 21-422 Page 3 codes of the City of Newport Beach, California. The completed work within this firm's purview to the extent observed, as discussed herein, has been reviewed and is considered adequate from a geotechnical perspective. As mentioned earlier herein, Petra was not contacted and therefore did not perform geotechnical observation of the foundation excavation for the northerly property line wall and as such, this item is not under the purview of this report. REPORT LIMITATIONS Representatives of Petra were present on -site on an on -call basis during post -grading operations for the purpose of providing the owner's representative with professional opinions and recommendations. These opinions and recommendations were developed based on field observation and selective testing of the contractor's work. Our scope of services during this project did not include supervision or direction of the contractor, his personnel or his subcontractors. As documented in this report, our observations and testing did not reveal any obvious deviations from the recommendations provided in the referenced geotechnical reports; however, Petra does not in any way guarantee the contractor's work, nor do our services relieve the contractor (or any subcontractors) of their liability should any defects subsequently be discovered in their work product. Based on our findings, this report was prepared in conformance with generally accepted professional engineering practices, and no warranty is implied nor made. This report is subject to review by the controlling authorities for the project. Please call if you have any questions pertaining to this report. Respectfully submitted, PET E CIENCES, INC. Don Obert Associate Engineer RGE 2872 SM/DO/Iv Attachments: Table I — Field Density Test Summary Table H — Laboratory Optimum Moisture and Maximum Dry Density Test Data Figure 1 — Density Test Location Map W'UON W25120214WllJA2210."o ,21A222W lim15oils hPon.'lo�x GPETRA SOLO ASA ROCK NICHOLSON CONSTRUCTION 225 Jasmine Avenue / Corona Del Mar TABLE FIELD DENSITY TEST SUMMARY June 18,2024 J.N. 21-422 Date of Test Test No. Location Depth* ft. Moist. % Unit Wt. bs./cu.ft.) % Rel. Comp. Soil Type 12/7/2022 1-IT Interior 0.5 12.9 110.1 92 A 12/7/2022 I -SG Building Pad 0.0 12.8 111.0 93 A 12/9/2022 1-S Exterior 1.5 11.6 108.6 91 A 12/9/2022 2-S Exterior 0.0 11.4 109.2 91 A 12/9/2022 1-W Exterior 0.5 12.6 109.9 92 A 12/9/2022 1-1 Exterior 1.0 12.2 110.2 92 A 3/20/2024 2-SG Drive Approach 0.0 11.7 111.4 93 A 3/20/2024 3-SG Side Patio 0.0 11.9 109.5 92 A 3/20/2024 4-SG Entry 0.0 10.8 111.2 93 A 3/20/2024 1-AD Side Yard 0.0 10.1 108.8 91 A SC - SUBGRADE IT - INTERIOR TRENCH S - SEWER W - WATER J - JOINT (ELECTRIC, TELEPHONE, TV, GAS) AD - AREA DRAIN * - DEPTH BELOW FINISH GRADE PETRA SOLID AS A ROCK NICHOLSON CONSTRUCTION June 18, 2024 225 Jasmine Avenue / Corona Del Mar J.N. 21-422 TABLE II LABORATORY OPTIMUM MOISTURE AND MAXIMUM DRY DENSITY TEST DATA Soil Type Optimum Moisture Maximum Dry Density ( /o) (PC,) A —Silty Sand (SM) 9.5 119.5 PETRASOaO ASA ROCK GEOSCIENCES— wmsaae.�w��w�I 111R a srs REMCEEX� Ntlld ONIMID ,nm VOO Iry VNnovI ELZ 31S ONbti151abO ONINIWV]2508Z OZS09Z S3dV3S11A10 30N30is3m anOdOL HC Ntlld 'JNICItlL9 3513321d a o ltq Q Q z z SOD00000 GeOOQ JGO G o w � Dd. SYi^ilV� 3➢43RV 3NIIIWr It a ,t i II z'i h, z d � 0 0 o 0 o lE E Ear w o a am�vv am3-�E d ¢ xc9Fw3 a 'a w—