Loading...
HomeMy WebLinkAboutX2020-1612 - Calcsi i KNA ENGINEERING, INC. !I I lranl r_c_)N"111 1 AN l `:, -- -- -- - --..—..----- -- - --- -- ...- -- -- - -- ----- 30923 C.-Inwood Strerrt • Suite 223 • Agoura Mills, CA 91 301 (818) 86 STRUCTURAL CALCULATIC Bio Retention Vault For KNA 14-016A 3235 Ocean Boulevard Corona Del Mar, CA DATED 1 /27/2021 PAGES 1 to 17 ITEM PAGE Wind Force 1 Bio-Retention with L-Footing 3 Bio-Retention with T-Footing 8 Bio-Retention with Slug Wall BUILDING DIVISION 13 CITY OF NEWPORT BEAGI { C-r'' '--V'ELOPi%P.EIll t:; °;' 4T OF THESE PLAFIS CC.' T; UTE 11 APPROVAL AUTI ir—IZATION TO CO""1 U I C L II C Jr,S ;TE1JT WITH THE C l ll.:: LiEACH THIS APPRCV/- CU j FF - Li p:-: PLL F1- I LCTS, IN Cad: C IT OFF. I 0;-,, r,I ICL 5 PLAI ! , - I U _iCl AHd , PERIVIi . IE;E THE i; ' U RFCIUIR' ai I ED EY S BF_FOI C. r WITH THE ORCIi', ' IF II'E';li`!�,FiaLWPGRIi�c- H "k.-Ki.lovVl-LDGEIVIENT - (SIGI'JATU=_ - SIGNATURF ,"1�. ,, r• -- t1k�N FD J UN 2 4 2021 BY: M.K 1/27/21 I Mt 3235 OcOqh B , 0 21 101, Cor on 17ON a Ne'l M ra (1) 0 r— 0 m > 0 Lo a C/) kD ry o 0 aro (1) Z' w uj LW (Y) C r 0 x o C) CL -0 dw) CL• X- C� (3 -a CL E > _C: a E > 0- E > CL E > 0- E > c ) a o o- C) o - 0 r_ 0 w U- U) CA ko ko N r- ko r- 00 0) 0 "0 w (U A 2 CL 0 m E O 2 'E VJ 0) cl m 0 m M o (D m V— uj cu (tj (1) N w 0� LO C�' 0 CL LIL w 8 S ej) LO C/) C'4 fJ z co 5 0) 0. 00 00 ko cUUJ 0 0 E m cp Carl cq 111 C/) 0 LLI -1 '2 0 +1 0 CL m LO (d •NL, ix I tD 0: v 41 A C) 0 Q) ca > 0 :3 CL LLJ 41 W 00 Ij- M ro Cr :3 C) 04 IIti 0 0 tools Design Pressure results littp:Hcaddtools-coiii/CfealculiteI 6,php ASCE 7-16 Wind load Program (30.3 Part i: Low -Rise Building Wall Components and Cladding) Wall Components and Cladding (Mean Roof I-leight h <= 6oft) Project: Enter Project Name Prepared by: Enter User Name of Company Name E-mail: Enter Email Address 3235 Ocean Blvd, Corona Del Mar 1/27/2021 2 of 17 Input: ASCE 7-16 Strength Design Load & Allowable Stress Design Wind Speed = 95 mph Building Exposure = D (Flat Unobstructed areas) Internal Pressure Coefficient GCpi = 0.18 Enclosed Building Roof angle is less than or equal to io' or flat (External Pressure Coefficient is reduced io%) Kzt i.00 Kd = 0.85 Ke i.00 Mean Roof Height = io ft output: Velocity Pressure Exposure Coefficient "I(z max." = 1.03 Per Table 20.10-1, page 268 LRFD uses wind speed Vult =. 95 mph Velocity Pressure (qh LRFD) = 20-93 Psf = .00256*1(z",ICzt",I(d:"Kel-V2 lb/ft/12 Iler eq.30.3-1, page 335 ASD uses wind speed VasdI = 74 mph Velocity Pressure (qh ASD) 12.14 Psf =.00256*Kz*"K/,t*IC(I",Ke*V"2'X*0.6 lb/ft'2 LRFD (Load Resistance D (Allowable Stress .1 Per Figure 30.4-1, Page Factorp�_ __ 335) Tributary Positive Negative Negative Positive egative NegativeF E, xternal Pressure Coefficients Area Sq Feet Zone 4 & 5 Center Zone 4 Corner Zone 5 Zone 4 & 5 Center 10 Zone 4 Corner Zone 5 Negative Corner psf Psf ps-f IL--- Psf Psf Psf 2_1-_8 — I 1 :---29 - =1 E ---i 7 7 1-- —1fi J — F 10 &"7T E - 7 5 20ft2 2o.9 E:-p-,7. =-27.2 =i6 _][=-=:i6_ .3 E-�6= =-0-94] -:t.:t6 1 5o­ft27E:i:j.=6E2i]=- 24A] -79 F _-o.8_8__1=-I,�=4 16 6 F —:i o o ft2'1= j-8.6 IF --2o-51 E�E:j�:]E,: �6 =-:t6 -0-8-3 E i:o: �q - �A-! [_17-7 2o.8 :t6 - =i6 =-:t6 [:0: -0-78 -0-85 [:5 0 =0ft- 2 1 =�- 4 —19-1 F-718.2 - -:to =-0-72 -18.2 i6JE�ii:�]' 0 =-7 2 [=7q—ft'2� - z --,.o- I !�-7 3 = =i6 - =i6 - =i6 =0.77 E-o.86 I= __ o::.ggj Least Width = 14 ft a = 3 ft (Zone 5) lo% of least width or 0.4h, whichever is smaller but not less than 3ft. Presented by CADDtools.com (q) 0- I of 2 1/27/2021, 10:43 AM „ Project Name/Number : 14-016a reten KNA ENGINEERING, INC. Title Bio-Retention H=4' L-Footing Page : 1 30423 Canwood Street, #223 Dsgnr: Date: 27 JAN 2021 Agoura Hills, CA 91301 Description.... ph: (818) 865-2026 3235 Ocean Blvd, Corona bel Mar knaeng@pacbell.net 1/27/2021 3 of 17 This Wall in File: C:\KNA Calc\2014\14-016 Tannir\2020-11-30 Bio Retention Vault\14-016a retention v RetainPro (c) 1987.2019, Build 11.20,03.31 License : KW-06068806 Cantilevered Retaining Wall Code: CBC 2019,AC1 318-14,TMS 402-16 License To: KNA ENGINEERING, INC. Criteria i I Soil Data r- Retained Height = 4.00 ft Wall height above soil = 0.00 ft Slope Behind Wall = 0.00 Height of Soil over Toe = 9.00 in Water height over heel = 0.0 ft Design Summary Wall Stability Ratios Overturning = 1.75 OK Sliding = 1.86 OK Total Bearing Load = 1,039 Ibs ...resultant ecc. = 6.22 in Allow Soil Bearing = 2,500.0 psf Equivalent Fluid Pressure Method Active Heel Pressure 35.0 psf/ft Passive Pressure = 400.0 psf/ft Soil Density, Heel = 110.00 pcf Soil Density, Toe = 110.00 pcf FootingIlSoil Friction = 0.350 Soil height to ignore for passive pressure = 0.00 in Lateral Load Applied to Stem Lateral Load = 0.0 #/ft ...Height to Top = 0.00 ft ...Height to Bottom = 0.00 ft Load Type = Wind (W) (Service Level) Wind on Exposed Stem = 0.0 psf (Service Level) Soil Pressure @ Toe = 1,141 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,500 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 1,598 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 3.1 psi OK Footing Shear @ Heel = 0.5 psi OK Allowable = 75.0 psi Sliding Calcs Lateral Sliding Force = 482.3 Ibs less 67 % Passive Force = - 532.8 Ibs less 100% Friction Force = - 363.6 Ibs Added Force Req'd = 0.0 Ibs OK ....for 1.5 Stability = 0.0 Ibs OK Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing Stem Construction Design Height Above Ftc ft= Wall Material Above "Ht" _ Design Method = Thickness = Rebar Size = Rebar Spacing = Rebar Placed at = Design Data fb/FB + fa/Fa = Total Force @ Section Service Level Ibs = Strength Level Ibs = Moment.... Actual Service Level ft-#= Strength Level ft-#= Moment..... Allowable = shear ..... Actual Service Level psi = Strength Level psi= Shear..... Allowable psi = Anet (Masonry) in2 = Rebar Depth V in = Masonry Data fm psi= Fs psi = Solid Grouting = Modular Ratio'n' _ Wall Weight psf= Bottom Adjacent Footing Load Adjacent Footing Load = 0.0 Ibs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 0.00 ft Footing Type Line Load Base Above/Below Soil = at Back of Wall 0.0 ft Poisson's Ratio = 0.300 Stem OK 0.00 Concrete LRFD 10.00 # 5 16.00 Edge 0.071 448.0 597.3 8,327.0 4.6 82.2 8.19 125.0 Load Factors Short Term Factor = Building Code CBC 2019,AC1 Equiv. Solid Thick. _ Dead Load 1.200 Masonry Block Type = Medium Weight Live Load 1.600 Masonry Design Method = ASD Earth, H 1.600 Concrete Data Wind, W 1.000 fc psi = 3,000.0 Seismic, E 1.000 Fy psi= 60,000.0 Project Name/Number : 14-016a reten KNA ENGINEERING, INC. Title Bio-Retention H=4' L-Footing Page : 2 30423 Canwood Street, #223 Dsgnr: Date: 27 JAN 2021 Agoura Hills, CA 91301 Description.... ph: (818) 865-2026 3235 Ocean Blvd, Corona Del Mar knaeng@pacbell.net 1/27/2021 4 of 17 This Wall in File: C:\KNA Calc\2014\14-016 Tannir\2020-11-30 Bio Retention Vault\14-016a retention v RetainPro (c) 1987.2019, Build 11.20.03.31 License: KW-06058806 Cantilevered Retaining Wall Code: CBC 2019,AC1 318-14,TMS 402-16 License To: KNA ENGINEERING, INC. Concrete Stern Rebar Area Details Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) : 0.0169 in2/ft (4/3) * As : 0.0225 in2/ft Min Stem T&S Reinf Area 0.960 in2 200bd/fy : 200(12)(8.1875)/60000 : 0.3275 in2/ft Min Stem T&S Reinf Area per ft of stem Height: 0.240 in2/ft 0.0018bh : 0.0018(12)(10) : 0.216 in2/ft Horizontal Reinforcing Options : One layer of: Two layers of: Required Area: 0.216 in2/ft #4@ 10.00 in #4@ 20.00 in Provided Area : 0.2325 in2/ft #5@ 15.50 in #5@ 31.00 in Maximum Area: 1.331 in2/ft #6@ 22.00 in #6@ 44.00 in Footing Data Toe Width = 1.42 ft Heel Width = 0.83 Total Footing Width = 2.25 Footing Thickness = 15.00 in Key Width = 0.00 in Key Depth = 0.00 in Key Distance from Toe = 0.00 ft fc = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0018 Cover @ Top 2.00 @ Btm = 3.00 in Footing Design Results T9g Hui Factored Pressure = 1,598 0 psf Mu': Upward = 14,256 0 ft-# Mu': Downward = 3,903 0 ft-# Mu: Design = 863 0 ft-# Actual 1-Way Shear = 3.06 0.52 psi Allow 1-Way Shear = 40.00 40.00 psi Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Footing Torsion, Tu = 0.00 ft-lbs Footing Allow. Torsion, phi Tu 0.00 ft-lbs If torsion exceeds allowable, provide supplemental design for footing torsion. Other Acceptable Sizes & Spacings Toe: phiMn = phi'5'lambda'sgrt(fc)'Sm Heel: phiMn = phi'5'lambda'sgrt(fc)'Sm Key: No key defined Min footing T&S reinf Area Min footing T&S reinf Area per foot If one layer of horizontal bars: #4@ 7.41 in #5@ 11.48 in #6@ 16.30 in 0.73 in2 0.32 in2 ift If two layers of horizontal bars: #4@ 14.81 in #5@ 22.96 in #6@ 32.59 in Project Name/Number : 14-016a reten KNA ENGINEERING, INC. Title Bio-Retention H=4' L-Footing Page : 3 30423 Canwood Street, #223 Dsgnr: Date: 27 JAN 2021 Agoura Hills, CA 91301 Description.... ph:(818)865-2026 knaeng@pacbell.net This Wall in File: C:\KNA Calc\2014\14-016 Tannir\2020-11-30 Bio Retention Vault\14-016a retention v RetainPro (c) 1987.2019, Build 11.20.03.31 License: Kw-06058806 Cantilevered Retaining Wall License To: KNA ENGINEERING, INC. ummar of Overturnin Resistin Forces &Moments .....OVERTURNING..... Force Distance Moment Item Ibs ft ft-# HL Act Pres (ab water tbl) HL Act Pres (be water tbl) Hydrostatic Force Buoyant Force = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = 482.3 1.75 Total = 482.3 O.T.M. = Resisting/Overturning Ratio = 1.75 Vertical Loads used for Soil Pressure = 1,038.8 Ibs 844.1 3235 Ocean Blvd, Corona bel Mar 1/27/2021 5 of 17 Code: CBC 2019,AC1 318-14,TMS 402-16 .....RESISTING..... Force Distance Moment Ibs ft ft-# Soil Over HL (ab. water tbl) 0.0 2.25 0.0 Soil Over HL (bel. water tbl) 2.25 0.0 Watre Table Sloped Soil Over Hee = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem= * Axial Live Load on Stem = Soil Over Toe = 116.9 0.71 82.8 Surcharge Over Toe = Stem Weight(s) = 500.0 1.83 916.8 Earth @ Stem Transitions= Footing Weighs 421.9 1.13 474.8 Key Weight = Vert. Component = Total = 1,038.8 Ibs R.M.= 1,474.4 * Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Tilt Harizontal ®eflectian at To of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.056 in The above calculption is not valid if the heel soil bearina pressure exceeds that of the toe because the wall would then tend to rotate into the retained soil. Project Name/Number : 14-016a reten KNA ENGINEERING, INC. Title Bio-Retention H=4' L-Footing Page: 4 30423 Canwood Street, #223 Dsgnr: Date: 27 JAN 2021 Agoura Hills, CA 91301 Description.... ph: (818) 866-2026 3235 Ocean Blvd, Corona bel Mar knaeng@pacbell.net 1/27/2021 6 of 17 This Wall in File: C:\KNA Calc\2014\14-016 Tannir\2020-11-30 Bio Retention Vault\14-016a retention v RetainPro (c) 1987-2019, Build 11.20.03.31 License: KW-06058806 Cantilevered Retaining Wall Code: CBC 2019,AC1 318-14,TMS 402-16 License To: KNA ENGINEERING, INC. 10, IN Project Name/Number : 14-016a reten KNA ENGINEERING, INC. Title Bio-Retention H=4' L-Footing Page: 5 30423 Canwood Street, #223 Dsgnr: Date: 27 JAN 2021 Agoura Hills, CA 91301 Description.... ph: (818) 865-2026 3235 Ocean Blvd, Corona Del Mar knaeng@pacbell.net 1/27/2021 7 of 17 This Wall in File: C:\KNA Calc\2014\14-016 Tannir\2020-11-30 Bio Retention Vault\14-016a retention v RetainPro (c) 1987-2019, Build 11.20.03.31 License: KW-06058806 Cantilevered Retaining Wall Code: CBC 2019,AC1 318-14,TMS 402-16 License To: KNA ENGINEERING, INC. Pip= 532.00i Hydrostatic Force Lateral earth fares re olLie to tl'l,@ soil BELOW wat rtablE Project Name/Number : 14-016a reten KNA ENGINEERING, INC. Title Bio-Retention H=4' T-Footing Page : 1 30423 Canwood Street, #223 Dsgnr: Date: 27 JAN 2021 Agoura Hills, CA 91301 Description.... ph: (818) 866-2026 3235 Ocean Blvd, Corona bel Mar knaeng@pacbell.net 1/27/2021 8 of 17 This Wall in File: C:\KNA Calc\2014\14-016 Tannir\2020-11-30 Bio Retention Vault\14-016a retention v License: KW-06058806 License To: KNA ENGINEERING INC. Criteria Retained Height = 4.00 ft Wall height above soil = 0.00 ft Slope Behind Wall = 0.00 Height of Soil over Toe = 9.00 in Water height over heel = 0.0 ft .Y:4: W Wall Stability Ratios Overturning = 1.95 OK Sliding = 2.04 OK Total Bearing Load = 1,292 Ibs ...resultant ecc. = 6.03 in Cantilevered Retaining Wall r. Allow Soil Bearing = 2,500.0 psf Equivalent Fluid Pressure Method Active Heel Pressure = 35.0 psf/ft Passive Pressure = 400.0 psf/ft Soil Density, Heel = 110.00 pcf Soil Density, Toe = 110.00 pcf FootingllSoil Friction = 0.350 Soil height to ignore for passive pressure = 0.00 in Lateral Load Applied to Stem mom Lateral Load = 0.0 #/ft ...Height to Top = 0.00 ft ...Height to Bottom = 0.00 ft Load Type = Wind (W) (Service Level) Wind on Exposed Stem = 0.0 psf (Service Level) Soil Pressure @ Toe = 1,383 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,500 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 1,936 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 0.6 psi OK Footing Shear @ Heel = 3.1 psi OK Allowable = 76.0 psi Sliding Calcs Lateral Sliding Force 482.3 Ibs less 67 % Passive Force = - 532.8 Ibs less 100% Friction Force = - 452.2 Ibs Added Force ll = 0.0 ibs OK ....for 1.5 Stability = 0.0 Ibs OK Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing Load Factors Building Code CBC 2019,ACI Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic, E 1.000 Code: CBC 2019,AC1 318-14,TMS 402-16 L Adjacent Footing Load Adjacent Footing Load = 0.0 Ibs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 0.00 ft Footing Type Line Load Base Above/Below Soil at Back of Wall = 0.0 ft Poisson's Ratio = 0.300 Stem Construction Bottom Stem OK Design Height Above FtE ft= 0.00 Wall Material Above "Ht" = Concrete Design Method - LRFD Thickness = 10.00 Rebar Size = # 5 Rebar Spacing = 16.00 Rebar Placed at = Edge Design Data fb/FB + fa/Fa = 0.071 Total Force @ Section Service Level Ibs = Strength Level Ibs= 448.0 Moment.... Actual Service Level ft-#= Strength Level ft-#= 597.3 Moment..... Allowable = 8,327.0 Shear..... Actual Service Level psi = Strength Level psi= 4.6 Shear..... Allowable psi= 82.2 Anet (Masonry) in2= Rebar Depth 'd' in = 8.19 Masonry Data fm psi= Fs psi = Solid Grouting - Modular Ratio'n' _ Wall Weight psf= 125.0 Short Term Factor = Equiv. Solid Thick. _ Masonry Block Type = Medium Masonry Design Method = ASD Concrete Data fc psi= 3,000.0 Fy psi= 60,000.0 Weight Project Name/Number : 14-016a reten KNA ENGINEERING, INC. Title Bio-Retention H=4' T-Footing Page : 2 30423 Canwood Street, #223 Dsgnr: Date: 27 JAN 2021 Agoura Hills, CA 91301 Description.... ph: (818) 865-2026 3235 Ocean Blvd, Corona Del Mar knaeng@pacbell.net 1/27/2021 9 of 17 This Wall in File: C:\KNA Calc\2014\14-016 Tannir\2020-11-30 Bio Retention Vault\14-016a retention v RetainPro (c) 1987-2019, Build 11.20.63.31 License; Kw-06068806 Cantilevered Retaining Wall Code: CBC 2019,AC1 318-14,TMS 402-1E License To: KNA ENGINEERING, INC. Concrete Stem Rebar Area Details Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) : 0.0169 in2/ft (4/3) * As: 0.0225 in2/ft Min Stem T&S Reinf Area 0.960 in2 200bd/fy : 200(12)(8.1875)/60000 : 0.3275 in2/ft Min Stem T&S Reinf Area per ft of stem Height: 0.240 in2/ft 0.0018bh : 0.0018(12)(10) : 0.216 in2/ft Horizontal Reinforcing Options : One layer of: Two layers of: Required Area : 0.216 in2/ft #4@ 10.00 in #4@ 20.00 in Provided Area : 0.2325 in2/ft #5@ 15.50 in #5@ 31.00 in Maximum Area: 1.331 in2/ft #6@ 22.00 in #6@ 44.00 in Footing Data Toe Width = 0.71 ft Heel Width = 1.54 Total Footing Width = 2.25 Footing Thickness = 15.00 in Key Width = 0.00 in Key Depth = 0.00 in Key Distance from Toe = 0.83 ft fc = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0018 Cover @ Top 2.00 @ Btm: 3.00 in Footing Design Results Toe BP-91 Factored Pressure 1,936 0 psf Mu': Upward = 5,092 6 ft-# Mu': Downward = 975 189 ft-# Mu: Design = 343 183 ft-# Actual 1-Way Shear = 0.57 3.06 psi Allow 1-Way Shear = 40.00 40.00 psi Toe Reinforcing = None Spec'd Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd Footing Torsion, Tu = 0.00 ft-Ibs Footing Allow. Torsion, phi Tu = 0.00 ft-Ibs If torsion exceeds allowable, provide supplemental design for footing torsion. Other Acceptable Sizes & Spacings Toe: phiMn = phi'5'lambda'sgrt(fc)'Sm Heel: phiMn = phi'5'lambda'sgrt(fc)'Sm Key: No key defined Min footing T&S reinf Area Min footing T&S reinf Area per foot If one layer of horizontal bars: #4@ 7.41 in #5@ 11.48 in #6@ 16.30 in 0.73 in2 0.32 in2 eft If two layers of horizontal bars: #4@ 14.81 in #5@ 22.96 in #6@ 32.59 in Project Name/Number : 14-016a reten KNA ENGINEERING, INC. Title Bio-Retention H=4' T-Footing Page : 3 30423 Canwood Street, #223 Dsgnr: Date: 27 JAN 2021 Agoura Hills, CA 91301 Description.... ph: (818) 865-2026 3235 Ocean Blvd, Corona bel Mar knaeng@pacbell.net 1/27/2021 10 of 17 This Wall in File: C:\KNA Calc\2014\14-016 Tannir\2020-11-30 Bio Retention Vault\14-016a retention v RetainPro (c) 1987-2019, Build 11.20.03.31 License : KW-06058806 Cantilevered Retaining Wall Code: CBC 2019,AC1 318-14,TMS 402-16 License To: KNA ENGINEERING. INC. Summary of Overturninq & Resistinq Forces & Moments Item Force Distance Moment Ibs ft ft-# .....RESISTING..... Force Distance Moment lbs. ft ft-# HL Act Pres (ab water tbl) 482.3 1.75 844.1, Soil Over HL (ab. water tbl) 311.7 1.90 590.9 HL Act Pres (be water tbl) Soil Over HL (bel. water tbl) 1.90 590.9 Hydrostatic Force Watre Table Buoyant Force = Sloped Soil Over Hee = Surcharge over Heel. Surcharge Over Heel = Surcharge Over Toe = Adjacent Footing Load = Adjacent Footing Load = Axial Dead Load on Stem= Added Lateral Load = Axial Live Load on Stem = Load @ Stem Above Soil = Soil Over Toe = 58.4 0.35 20.7 = Surcharge Over Toe _ Stem Weight(s) = 500.0. 1.13 562.5 Earth @ Stem Transitions= Total = 482.3 O.T.M. = 844.1 Footing Weighi - 421.9 1.13 474.6 Key Weight = 0.83 Resisting/Overturning Ratio = 1.95 Vert. Component = Vertical Loads used for Soil Pressure = 1,292.0 Ibs Total = 1,292.0 Ibs R.M.= 1,648.7 * Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Tilt Horizontal Deflection t ToD of Wall due to settlement of soil (Deflection due to wall bending hot considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.068 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe because the wall would then tend to rotate into the retained soil Project Name/Number : 14-016a reten KNA ENGINEERING, INC. Title Bio-Retention H=4' T-Footing Page : 4 30423 Canwood Street, #223 Dsgnr: Date: 27 JAN 2021 Agoura Hills, CA 91301 Description.... ph: (818) 865-2026 3235 Ocean Blvd, Corona Del Mar knaeng@pacbell.net 1/27/2021 11 of 17 This Wall in File: C:\KNA Calc\2014\14-016 Tannir\2020-11-30 Bio Retention Vault\14-016a retention v rceiainrro (c) iaoi-zuia, esuua 'ri.14u.uss1 License: Kw-06068806 Cantilevered Retaining Wall Code: CBC 2019,AC1 318-14,TMS 402-16 License To: KNA ENGINEERING, INC. 10" wt #5 @ 1" Project Name/Number : 14-016a reten KNA ENGINEERING, INC. Title Bio-Retention H=4' T-Footing Page : 5 30423 Canwood Street, #223 Dsgnr: Date: 27 JAN 2021 Agoura Hills, CA 91301 Description.... ph: (818) 865-2026 3235 Ocean Blvd, Corona bel Mar knaeng@pacbell.net 1/27/2021 12 of 17 This Wall in File: C:\KNA Calc\2014\14-016 Tannir\2020-11-30 Bio Retention Vault\14-016a retention v RetainPro (c) 1987.2019, Build 11.20.03.31 License : Kw-06058806 Cantilevered Retaining Wall Code: CBC 2019,AC1 318-14,TMS 402-16 License To: KNA ENGINEERING, INC. MM Hydrostatic orc;e L at rat earth pros SUre dLIo to the -oil BELOVY water tabk Project Name/Number : 14-016a reten KNA ENGINEERING, INC. Title Pool.Bath Slough Wall Page: 1 30423 Canwood Street, #223 Dsgnr: AY Date: 27 MAY 2020 Agoura Hills, CA 91301 Description.... ph: (818) 866-2026 3235 Ocean Blvd, Corona bel Mar knaeng@pacbell.net 1/27/2021 13 of 17 This Wall in File: C:\KNA Calc\2014\14-016 Tannir\2020-11-30 Bio Retention Vault\14-016a retention v KetainPro (c) 19S7.2019, BUlld 11.211.03.31 License: KW-06058806 Cantilevered Retaining Wall License To: KNA ENGINEERING, INC. Criteria 11111 1 Soil Data Retained Height = 3.50 ft Wall height above soil = 0.00 ft Slope Behind Wall = 0.00 . Height of Soil over Toe = 9.00 in Water height over heel = 0,0 ft Wall Stability Ratios Overturning = 1.63 OK Sliding = 1.65 OK Total Bearing Load = 1,689 Ibs ...resultant ecc. = 8.58 in Allow Soil Bearing = 2,500.0 psf Equivalent Fluid Pressure Method Active Heel Pressure = 90.0 psf/ft Passive Pressure = 400.0 psf/ft Soil Density, Heel = 110.00 pcf Soil Density, Toe = 110.00 pcf FootingllSoil Friction = 0.350 Soil height to ignore for passive pressure = 0.00 in Lateral Load Applied to Stem Lateral Load = 0.0 #/ft ...Height to Top = 0.00 ft ...Height to Bottom = 0.00 ft Load Type = Wind (W) (Service Level) Wind on Exposed Stem = 0.0 psf (Service Level) Soil Pressure @ Toe = 1,550 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,500 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 2,171 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 1.0 psi OK Footing Shear @ Heel = 6.1 psi OK Allowable = 75.0 psi Sliding Calcs Lateral Sliding Force = 1,015.3 Ibs less 100% Passive Force = - 1,088.9 Ibs less 100% Friction Force = - 591.1 Ibs Added Force Req'd = 0.0 Ibs OK ....for 1.5 Stability = 0.0 Ibs OK Stem Construction Design Height Above Ftc ft = Wall Material Above "Ht" _ Design Method = Thickness = Rebar Size = Rebar Spacing = Rebar Placed at = Design Data fb/FB + fa/Fa = Total Force @ Section Service Level Ibs = Strength Level Ibs = Moment.... Actual Service Level ft-# = Strength Level ft-# = Moment..... Allowable = Shear..... Actual Service Level psi = Strength Level psi = Shear..... Allowable psi = Anet (Masonry) in2 = Rebar Depth 'd' in = Masonry Data fm psi = Fs psi = Vertical component of active lateral soil pressure IS Solid Grouting = considered in the calculation of soil bearing pressures. Modular Ratio'n' _ Bottom Code: CBC 2016,AC1 318-14,AC1 530-13 Adjacent- Footing Load Adjacent Footing Load = 0.0 Ibs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 0.00 ft Footing Type Line Load Base Above/Below Soil = 0.0 ft at Back of Wall Poisson's Ratio = 0.300 Stem OK 0.00 Concrete LRFD 6.00 # 5 16.00 Edge 0.251 882.0 1,029.0 4,094.1 17.6 75.0 4.19 Wall Weight psf = 75.0 Load Factors Short Term Factor = Building Code CBC 2016,ACI Equiv. Solid Thick. _ Dead Load 1.200 Masonry Block Type = Medium Weight Live Load 1.600 Masonry Design Method = ASD Earth, H 1.600 Concrete Data Wind, W 1.000 fc psi = 2,500.0 Seismic, E 1.000 Fy psi = 60,000.0 Project Name/Number : 14-016a reten KNA ENGINEERING, INC. Title Pool:Bath Slough Wall Page : 2 30423 Canwood Street, #223 Dsgnr: AY Date: 27 MAY 2020 Agoura Hills, CA 91301 Description.... ph: (818) 865-2026 3235 Ocean Blvd, Corona Del Mar knaeng@pacbell.net 1/27/2021 14 of 17 This Wall in File: C:\KNA Calc\2014\14-016 Tannir\2020-11-30 Bio Retention Vauit\14-016a retention v RetainPro (c) 1987.2019, Build 11.20.03.31 License: KW-06058806 Cantilevered Retaining Wall Code: CBC 2016,AC1 318-14,AC1 530-13 License To: KNA ENGINEERING, INC. Concrete Stem Rebar Area Details Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) : 0.0591 in2/ft (4/3) * As: 0.0788 in2/ft Min Stem T&S Reinf Area 0.504 in2 200bd/fy : 200(12)(4.1875)/60000 : 0.1675 in2/ft Min Stem T&S Reinf Area per ft of stem Height: 0.144 in2/ft 0.0018bh : 0.0018(12)(6) : 0.1296 in2/ft Horizontal Reinforcing Options : One layer of: Two layers of: Required Area : 0.1296 in2/ft #4@ 16.67 in #4@ 33.33 in Provided Area : 0.2325 in2/ft #5@ 25.83 in #5@ 51.67 in Maximum Area: 0.5673 in2/ft #6@ 36.67 in #6@ 73.33 in Footing Data Toe Width = 0.50 ft Heel Width = 2.25 Total Footing Width = 2.75 Footing Thickness = 15.00 in Key Width = 10.00 in Key Depth = 4.00 in Key Distance from Toe = 0.00 ft f'c = 2,500 psi Fy = 60,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0018 Cover @ Top 2.00 @ Btm = 3.00 in Footing Design Results Ige Bpe Factored Pressure = 2,171 0 psf Mu': Upward = 2,982 172 ft-# Mu': Downward = 486 1,483 ft-# Mu: Design = 208 1,311 ft-# Actual 1-Way Shear = 1.05 6.15 psi Allow 1-Way Shear = 40.00 75.00 psi Toe Reinforcing = None Spec'd Heel Reinforcing = # 6 @ 16.00 in Key Reinforcing = # 5 @ 16.00 in Footing Torsion, Tu = 0.00 ft-Ibs Footing Allow. Torsion, phi Tu = 0.00 ft-Ibs If torsion exceeds allowable, provide supplemental design for footing torsion. Other Acceptable Sizes & Spacings Toe: phiMn = phi'5'lambda'sgrt(fc)'Sm Heel: #4@ 7.40 in, #5@ 11.48 in, #6@ 16.29 in, #7@ 22.22 in, #8@ 29.25 in, #9@ 37 Key: phiMn = phi'5'lambda'sgrt(fc)'Sm Min footing T&S reinf Area Min footing T&S reinf Area per foot If one layer of horizontal bars: #4@ 7.41 in #5@ 11.48 in #6@ 16.30 in 0.89 in2 0.32 in2ft If two layers of horizontal bars: #4@ 14.81 in #5@ 22.96 in #6@ 32.59 in Project Name/Number : 14-016a reten KNA ENGINEERING, INC. Title Pool Bath Slough Wall 30423 Canwood Street, #223 Dsgnr: AY Agoura Hills, CA 91301 Description.... ph: (818) 865-2026 knaeng@pacbell.net This Wall in File: C:\KNA Calc\2014\14-016 Tannir\2020-11-30 Bio Retention Vault\14-016a retention v RetainPro (c) 1987-2019, Build 11.20.03.31 License: KW-06058806 Cantilevered Retaining Wail License To: KNA ENGINEERING, INC. �ummar of ®verturnin & R�sistin Fords &Moments .....OVERTURNING..... Force Distance Moment Item Ibs ft ' ft-# HL Act Pres (ab water tbl) HL Act Pres (be water tbl) Hydrostatic Force Buoyant Force = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = 1,015.3 1.58 Total = 1,015.3 O.T.M. = Page : 3 Date: 27 MAY 2020 3235 Ocean Blvd, Corona Del Mar 1/27/2021 15 of 17 Code: CBC 2016,AC1 318-14,AC1 530-13 1,607.6 Soil Over HL (ab. water tbl) Soil Over HL (be]. water tbl) Watre Table Sloped Soil Over Hee = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = *Axial Live Load on Stem = Soil Over Toe = Surcharge Over Toe = Stem Weight(s) _ Earth @ Stem Transitions= Resisting/Overturning Ratio = 1.63 Vertical Loads used for Soil Pressure = 1,688.9 Ibs I,VVI.V Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. dh- 11MUOTIV.11111 r# 11 :1; LII Z :: III .....RESISTING..... Force Distance Moment Ibs ft ft-# 673.8 1.88 1,263.3 1.88 1,263.3 41.3 0.25 10.3 262.5 0.75 196.9 Footing Weighi = 515.6 1.38 709.0 Key Weight = 41.7 0.42 17.4 Vert. Component = 154.1 2.75 423.7 Total = 1,688.9 Ibs R.M.= 2,620.5 * Axial live load NOT included in total displayed or used for overturning resistance, but is included for soil pressure calculation. (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.055 in The above calculation is not valid if the heel soil bearing Dressure exceeds that of the toe because the wall would then tend to rotate into the retained soil Project Name/Number : 14-016a reten KNA ENGINEERING, INC. Title Pool Bath Slough Wall Page : 4 30423 Canwood Street, #223 Dsgnr: AY Date: 27 MAY 2020 Agoura Hills, CA 91301 Description.... ph: (818) 866-2026 3235 Ocean Blvd, Corona Del Mar knaeng@pacbell.net 1/27/2021 16 of 17 This Wall in File: C:\KNA.Calc\2014\14-016 Tannir\2020-11-30 Bio Retention Vault\14-016a retention v ��a °, w 05 @ _16- 1?i "I ►a. in @ 'Center On Key ` '16- I- ed Cantilevered Retaining Wall Code: CBC 2016,AC1 318-14,AC1 530-13 Project Name/Number : 14-016a reten KNA ENGINEERING, INC. Title Pool Bath Slough Wall Page : 5 30423 Canwood Street, #223 Dsgnr: AY Date: 27 MAY 2020 Agoura Hills, CA 91301 Description.... ph: (818) 866-2026 3235 Ocean Blvd, Corona Del Mar knaeng@pacbell.net 1/27/2021 17 of 17 This Wall in File: C:\KNA Calc\2014\14-016 Tannir\2020-11-30 Bio Retention Vault\14-016a retention v KetainPro (c) 1987-2019, Build 11.20.03.31 License: Kw-06058806 Cantilevered Retaining Wall Code: CBC 2016,AC1 318-14,AC1 530-13 License To: KNA ENGINEERING, INC. Pp= 1108 .5 Hydrastatic Farce Lateral earti-i pressur due to; the uil BELOW water table KNA ENGINEERING, INC. I I R P -' A I I I .,,\N I S ........ ...... A'() f.)', I [r(ct - S I j I te 2-2 /\"3ok If I I idl, )I FAX mim 8:") STRUCTURAL CALCULATIONS ITEM Deck Joist Retaining Wall Partial Soil Report Bio Retention Vault For KNA 14-016A 3235 Ocean Boulevard Corona Del Mar, CA DATED 11 /30/2020 PAGES I to 9 BUILDING DIvISI0t4 Dl,(-, '—, - BY M.K PAGE 1 3 8 11/30/20 KAN ENGINEERING, INC. 30423 Canwood Street Agoura Hills, CA 91301 ph: (818) 865-2026 knaeng@pacbell,net 3235 Ocean Blvd, Corona Del Mar KNA14-016A 11/30/2020 1 of 9 Wood Beam Software copyright ENERCALC, INC. 19834 DESCRIPTION: Deck Joist CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: ASCE 7-16 Material Properties Analysis Method: Allowable Stress Design Fb + 1000 psi E : Modulus of Elasticity Load Combination ASCE 7-16 Fb - 1000 psi Ebend- xx 17OOksi Fc - Prll 1500 psi Eminbend - xx 620 ksi Wood Species ; Douglas Fir - Larch Wood Grade ; No.1 Beam Bracing : Beam is Fully Braced against lateral - - -- - Fc - Perp Fv Ft -torsional buckling 625 psi 180 psi 675 psi Density 31.21 pcf Repetitive Member Stress Increase D(0.0133) L(0.0532)--------- 2x10 A Span = 15.0 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loads Uniform Load ; D = 0.010, L = 0.040 ksf, Tributary Width = 1.330 it Maximum Bending Stress Ratio = 0.867: 1 Maximum Shear Stress Ratio = 0.281 : 1 Section used for this span 2x10 Section used for this span 2x10 fb: Actual = 1,096.68psi fv: Actual = 50.60 psi Fb: Allowable = 1,265.00psi Fv: Allowable 180.00 psi Load Combination +D+L+H Load Combination +D+L+H Location of maximum on span = 7.500ft Location of maximum on span = 14.234ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.362 In Ratio = 496>=360 Max Upward Transient Deflection 0.000 In Ratio = 0 <360 Max Downward Total Deflection 0.474 In Ratio = 380>=180 Max Upward Total Deflection 0.000 in Ratio = 0 <180 Overall Maximum Deflections Load Combination Span Max. "-" Defl Location in Span Load Combination Max. "+" Defl Location in Span +D+L+H 1 0.4735 7.555 0,0000 0,000 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 0.521 0.521 Overall MINimum 0.399 0.399 +D+H 0.122 0.122 +D+L+H 0.521 0.521 +D+Lr+H 0.122 0.122 +D+S+H 0.122 0,122 +D+0.750Lr+0.750L+H 0.422 0,422 +D+0.750L+0.750S+H 0.422 0.422 +D+0.60W+H 0.122 0.122 +D+0.750Lr+0.750L+0.450W+H 0.422 0.422 KAN ENGINEERING, INC. 30423 Canwood Street Agoura Hills, CA 91301 ph: (818) 865-2626 -" knaeng@pacbell.net 3235 Ocean Blvd, Corona Del Mar KNA14-016A 11/30/2020 2 of 9 Wood Beam Fie: 4-016A.ec Software copyright ENERCALC, I NC. 1983-2020, Build:12.20.8.1' DESCRIPTION: Deck Joist Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 +D+0.750L+0.750S+0.450W+H 0,422 0.422 +0.60D+0,60W+0.60H 0.073 0,073 +D+0,70E+0,60H 0.122 0.122 +D+0.750L+0.750S+0.5250E+H 0,422 0.422 +0.60D+0.70E+H 0.073 0.073 D Only 0.122 0.122 L Only 0,399 0.399 H Only Project Name/Number : 14-016a reten KNA ENGINEERING, INC. Title Page: 1 30423 Canwood Street, #223 Dsgnr: Date: 30 NOV 2020 Agoura Hills, CA 91301 Description.... 3235 Ocean Blvd, Corona Del Mar ph: ng pacbe 1. KNA14-016A 11/30/2020 3 of 9 knaeng@pacbell.net This Wall in File: c:\kna calc\2014\14-016 tannir\2020-11-30 retention vault\14-016a retention vault RetainPro (c) 1987-2019, Build 11.20.03.31 License: KW-06058806 Cantilevered Retaining Wall Code: CBC 2019,AC1 318-14,TMS 402-16 License To: KNA ENGINEERING, INC. Criteria Retained Height = 5.00 ft Wall height above soil = 0.00 ft Slope Behind Wall = 0.00 Height of Soil over Toe = 9.00 in Water height over heel = 0.0 ft Surcharge Loads Surcharge Over Heel = 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 Ibs Axial Live Load = 0.0 Ibs Axial Load Eccentricity = 0.0 in Design Summary Wall Stability Ratios Overturning = 2.19 OK Sliding = 1.53 OK Total Bearing Load = 1,456 Ibs ...resultant ecc. = 6.01 in Soil Data Allow Soil Bearing = 2,500.0 psf Equivalent Fluid Pressure Method Active Heel Pressure = 35.0 psf/ft Passive Pressure = 400.0 psf/ft Soil Density, Heel = 110.00 pcf Soil Density, Toe = 110.00 pcf FootingllSoil Friction = 0.350 Soil height to ignore for passive pressure = 0.00 in Lateral Load Applied to Stem Lateral Load = 0.0 #/ft ...Height to Top = 0.00 ft ...Height to Bottom = 0.00 ft Load Type = Wind (W) (Service Level) Wind on Exposed Stem = 0.0 psf Soil Pressure @ Toe = 830 psf OK Soil Pressure @ Heel = 43 psf OK Allowable = 2,500 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 1,163 psf ACI Factored @ Heel = 61 psf Footing Shear @ Toe = 6.2 psi OK Footing Shear @ Hee = 0.0 psi OK Allowable = 75.0 psi Sliding Calcs Lateral Sliding Force = 683.6 Ibs less 67 % Passive Force = - 532.8 Ibs less 100% Friction Force = - 509.7 Ibs Added Force Req'd = 0.0 Ibs OK ....for 1.5 Stability = 0.0 Ibs OK Vertical component of active lateral soil pressure IS NOT considered in the calculation of soil bearing Load Factors Building Code CBC 2019,ACI Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic, E 1.000 (Service Level) Stem Construction Design Height Above Ftc ft = Wall Material Above "Ht" _ Design Method = Thickness = Rebar Size = Rebar Spacing = Rebar Placed at = Design Data fb/FB + fa/Fa = Total Force @ Section Service Level Ibs = Strength Level Ibs = Moment.... Actual Service Level ft-# = Strength Level ft-# = Moment..... Allowable = Shear..... Actual Service Level psi = Strength Level psi = Shear..... Allowable psi = Anet (Masonry) in2 = Rebar Depth 'd' in = Masonry Data fm psi = Fs psi = Solid Grouting = Modular Ratio'n' _ Wall Weight psf= Short Term Factor = Bottom Adjacent Footing Load Adjacent Footing Load = 0.0 Ibs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 0.00 ft Footing Type Line Load Base Above/Below Soil at Back of Wall = 0.0 ft Poisson's Ratio = 0.300 Stem OK 0.00 Concrete LRFD 10.00 # 5 16.00 Edge 0.140 700.0 1,166.7 8,327.0 7.1 82.2 8.19 125.0 Equiv. Solid Thick. _ Masonry Block Type = Medium Weight Masonry Design Method = ASD Concrete Data fc psi = 3,000.0 Fy psi = 60,000.0 Project Name/Number : 14-016a reten KNA ENGINEERING, INC. Title Page : 2 30423 Canwood Street, #223 Dsgnr: Date: 30 NOV 2020 Agoura Hills, CA 91301 Description.... 3235 Ocean Blvd, Corona Del Mar ph: (818) 865-2026 knaeng@pacbell.net KNA14-016A 11/30/2020 4 of 9 This Wall in File: c:\kna calc\2014\14-016 tannir\2020-11-30 retention vault\14-016a retention vault RetainPro (c) 1987-2019, Build 11.20.03.31 License : KW-06058806 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16 License To: KNA ENGINEERING, INC. Concrete Stem Rebar Area Details Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) : 0.0329 in2/ft (4/3) " As: 0.0439 in2/ft Min Stem T&S Reinf Area 1.200 in2 200bd/fy : 200(12)(8.1875)/60000 : 0.3275 in2/ft Min Stem T&S Reinf Area per ft of stem Height : 0.240 in2/ft 0.0018bh : 0.0018(12)(10) : 0.216 in2/ft Horizontal Reinforcing Options : One layer of: Two layers of: Required Area : 0.216 in2/ft #4@ 10.00 in #4@ 20.00 in Provided Area : 0.2325 in2/ft #5@ 15.50 in #5@ 31.00 in Maximum Area: 1.331 in2/ft #6@ 22.00 in #6@ 44.00 in Footing Data Footing Design Results Toe Width = 2.50 ft Toe Heel Heel Width = 0.83 Factored Pressure = 1,163 61 psf Total Footing Width 3.33 Mu': Upward = 33,267 0 ft-# Footing Thickness = 15.00 in Mu': Downward = 12,150 0 ft-# Mu: Design = 1,760 0 ft-# Key Width = 0.00 in Actual 1-Way Shear = 6.15 0.00 psi Key Depth = 0.00 in Allow 1-Way Shear = 75.00 0.00 psi Key Distance from Toe = 0.00 ft Toe Reinforcing = # 5 @ 16.00 in fc = 2,500 psi Fy = 60,000 psi Heel Reinforcing = # 5 @ 16.00 in Footing Concrete Density = 150.00 pcf Key Reinforcing = None Spec'd Min. As % = 0.0018 Footing Torsion, Tu = 0.00 ft-Ibs Cover @ Top 2.00 @ Btm= 3.00 in Footing Allow. Torsion, phi Tu = 0.00 ft-Ibs If torsion exceeds allowable, provide supplemental design for footing torsion. Other Acceptable Sizes & Spacings Toe: #4@ 7.40 in, #5@ 11.48 in, #6@ 16.29 in, #7@ 22.22 in, #8@ 29.25 in, #9@ 37 Heel: #4@ 7.40 in, #5@ 11.48 in, #6@ 16.29 in, #7@ 22.22 in, #8@ 29.25 in, #9@ 37 Key: No key defined Min footing T&S reinf Area 1.08 in2 Min footing T&S reinf Area per foot 0.32 in2 A If one layer of horizontal bars: If two layers of horizontal bars: #4@ 7.41 in #4@ 14.81 in #5@ 11.48 in #5@ 22.96 in #6@ 16.30 in #6@ 32.59 in Project Name/Number : 14-016a reten KNA ENGINEERING, INC. Title Page : 3 30423 Canwood Street, #223 Dsgnr: Date: 30 NOV 2020 Agoura Hills, CA 91301 Description.... 3235 Ocean Blvd, Corona t)el Mar ph: (818) 865-2026 knaeng@pacbell.net KNA14-016A 11/30/2020 5 of 9 This Wall in File: c:\kna calc\2014\14-016 tannir\2020-11-30 retention vault\14-016a retention vault RetainPro (c) 1987-2019, Build 11.20.03.31 License : KW-06058806 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16 License To: KNA ENGINEERING. INC. Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... .....RESISTING..... Force Distance Moment Force Distance Moment Item Ibs ft ft-# Ibs ft ft-# HL Act Pres (ab water tbl) 683.6 2.08 1,424.2 Soil Over HL (ab. water tbl) 0.0 3.33 0.0 HL Act Pres (be water tbl) Soil Over HL (be]. water tbl) 3.33 0.0 Hydrostatic Force Watre Table Buoyant Force = Sloped Soil Over Hee = Surcharge over Heel = Surcharge Over Heel = Surcharge Over Toe = Adjacent Footing Load = Adjacent Footing Load = Axial Dead Load on Stem= Added Lateral Load = *Axial Live Load on Stem = Load @ Stem Above Soil = Soil Over Toe = 206.3 1.25 257.8 = Surcharge Over Toe = Stem Weight(s) = 625.0 2.92 1,822.9 Earth @ Stem Transitions= Total = 683.6 O.T.M. = 1,424.2 Footing Weight - 625.0 1.67 1,041.7 Key Weight = Resisting/Overturning Ratio = 2.19 Vert. Component = Vertical Loads used for Soil Pressure = 1,456.3 Ibs Total = 1,456.3 Ibs R.M.= 3,122.4 Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Overturning Resistance. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.035 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe because the wall would then tend to rotate into the retained soil. Project Name/Number : 14-016a reten KNA ENGINEERING, INC. Title Page : 4 30423 Canwood Street, #223 Dsgnr: Date: 30 NOV 2020 Agoura Hills, CA 91301 Description.... 3235 Ocean Blvd, Corona bel Mar ph: (818) 865-2026 knaeng@pacbell.net KNA14-016A 11/30/2020 6 of 9 This Wall in File: c:\kna calc\2014\14-016 tannir\2020-11-30 retention vault\14-016a retention vault Retain Pro (c) 1987-2019, Build 11.20.03.31 License : KW-06058806 Cantilevered Retaining Wall Code: CBC 2019,AC1 318-14,TMS 402-16 License To: KNA ENGINEERING, INC. 601 #5@ 1 Toe #616° Heel Project Name/Number : 14-016a reten KNA ENGINEERING, INC. Title Page : 5 30423 Canwood Street, #223 Dsgnr: Date: 30 NOV 2020 Agoura Hills, CA 91301 Description.... 3235 Ocean Blvd, Corona bel Mar ph.- (818) 866-2026 knaeng@pacbell.net KNA14-016A 11/30/2020 7 of 9 This Wall in File: c:\kna calc\2014\14-016 tannir\2020-11-30 retention vault\14-016a retention vault License: KW-06058806' emu'"' ' !'`V'U�'� 1 Cantilevered RetainingWall License To : KNA ENGINEERING, INC. Code: CBC 2019,AC1 318-14,TMS 402-16 Pp= D3Z80# M: C-4 C, c-a cry tt LO ME Hyd tstio Faice Lateral earth pressure date to the sail SELOW water table September 12, 2013 3235 Ocean Blvd, Corona Del Mar P mAl 1go6A ll fl /�7� 8 of 9 Report No: 13-7345r Page No: 14 slabs be underlain by a 15-mil thick vapor retarder/barrier (Stego Wrap or equivalent) placed over the gravel in accordance with the requirements of ASTM E:1745 and E:1643. Conventional spread footings embedded into competent bedrock or terrace deposits may be designed for an allowable bearing value of 4000 or 2500 pounds per square foot, respectively. Footings should be designed with a minimum width of 18 inches and a minimum embedment of 24 inches below the lowest adjacent grade. Actual footing depth and width should be governed by CBC requirements and the structural engineering design. The design value may be increased one-third for short duration wind or seismic loading. Settlement due to footing loads is anticipated to be nil in bedrock and 3/4-inch in terrace deposits. Lateral loads may be resisted by passive pressure forces and by friction acting on the bottom of footings. The allowable passive pressure forces may be computed using an equivalent fluid density of 400 pounds per cubic foot for bedrock and terrace deposits. A coefficient of friction of 0.35 may be used in computing the frictional resistance. 2. Moisture Content of Slab Subgrade Soils Presoaking of slab subgrade soils is recommended prior to construction of slabs. We recommend that subgrade soils be soaked to at least 140 percent of optimum moisture content to a depth of 18-inches or more prior to placing gravel. 3. ' Caissons Caissons utilized for foundation support and shoring/retaining walls should be a minimum 24-inch diameter and embedded into competent bedrock a minimum depth of 10 feet. Caissons may be designed for a dead plus live load end bearing value of 10,000 pounds per square foot for bedrock. These values may be increased by one-third for wind and seismic forces. A skin friction value of 400 pounds per square foot may also be used for bedrock. Settlement of caisson foundations in bedrock is anticipated to be less than 1/4-inch. Lateral resistance may be computed utilizing 400 pounds per square foot per foot of depth for competent bedrock or terrace deposits. The lateral resistance value provided above for bedrock may act on a tributary area of twice the caisson diameter. No lateral resistance may be taken in the beach deposits, slope wash or fill material. An allowable coefficient of friction of 0.35 may be assumed for bedrock. 4. Slope Setback The base of all footings and caissons should be deepened as necessary to establish a horizontal distance of 15 feet as measured from the bottom edge of the foundation to the slope face. 3235 Ocean Blvd, Corona Del Mar September 12, 2013 Pf6 ect I�o6A 11� �G ?� 9 of 9 Report No: 13-7345r Page No: 16 Structural Design of Shoring/Retaining Walls Lateral pressure forces acting on cantilevered shoring/retaining walls retaining level granular soil, terrace deposits or bedrock may be designed utilizing an equivalent fluid pressure of 35 pounds per cubic foot. Wall rotation on the order of 0.1 percent of the wall height should be anticipated and considered in the design for active earth pressure walls. Restrained walls should be designed utilizing an equivalent fluid pressure of 60 pounds per cubic foot. The garage/recreation room wall adjacent to the slope should be designed as a retaining wall/debris wall. The retaining/debris wall for the garage/recreation room should be designed using an active equivalent fluid pressure of 120 pounds per cubic foot with a design height of 3 feet. Retaining wall and shoring design must consider topographic and structural surcharges from existing and adjacent improvements. Seismic design of retaining walls may be based on the Mononobe-Okabe method, as updated by Atik and Sitar (2010), using an additional dynamic load of 15 pounds per cubic foot equivalent fluid pressure acting at 1/3 H above the base of the wall. Final design requirements should be determined by the structural engineer. Retaining Wall Subdrains The drainage schemes depicted on Figures 3 and 4, or geotechnically approved alternatives, should be used to reduce the potential for seepage forces behind retaining walls. Waterproofing of retaining walls is recommended and should be applied in accordance with the architect's specifications or those of a waterproofing consultant. Hardscaning Hardscaping elements such as walls and patio slabs should be designed for an allowable bearing value of 2500 pounds per square foot for terrace deposits or approved granular compacted fill. Allowable passive pressure forces may be computed using an equivalent fluid density of 200 pounds per cubic foot and a coefficient of friction of 0.30. Planters in the vicinity of footings should be sealed and drained. Concrete Laboratory test results indicate onsite derived soils have a negligible sulfate content. However, as the concrete is in a marine environment, a moderate sulfate exposure should be used for design purposes. The concrete mix should be designed by a concrete expert in consideration of structural requirements and anticipated exposure. In lieu of a specific design, applicable recommendations as presented in the 2010 CBC, Section 1904.3, may be utilized, which refers to ACI 318, Table 4.3, which recommends Type II cement, a maximum water -cement ratio of 0.50, and a minimum design unconfined compressive strength of 4,000 psi, if exposed to sea water. KNA ENGINEERING, INC. 1-[)[',,Al (--ONIJI I AN I S W STRUCTURAL CALCULATIONS Pool Both Debris Wal For KNA 14-016A 3235 Ocean Boulevard Corona Del Mar, CA DATED I'l /23/2020 PAGES I to 15 ITEM PAGE Partial soil Report I Debris Wall 4 Pile 9 DEC 1 4 I 114-K CITY OF fIEWPORT 8FAGI I I" ! i-L-V1011WF:;[ F)cPAP M;F!-1T APPROVAL OF IIIEEL PIAIIS !-,i, i t .;)S I [ i U T[-_ C>% -, - I M, - PLIED A� T - ; I 11— Le I . i — )RF —) I H ill I )i-AA""' THS APPROW[ UIJ,V <,,1 111 i I is CO,,1P At L f ' 'I I'[ (,JS IN , tilll CITY 17 ti POLICIES �!I D OF S P T PERMIT;:._ !.VISE 1, IF— �)R FD BY 1i ANS BEF C, TO WITH THE ORIjINAI,J(,LS: PL—jzi P( f.IF_VJPOR-r P " PL 1 S ACKFJOVVLEDGEMENT: (SIGNATURE) Eil f -"I; hT SIGNATURE G1 -L,'�VICES Gf. PL [:.ill L/NuP APPROVAL TO ISSUE BUILDING: DATE:_ 11/23/20 Mar Q O w 2 z :i Fn 0 z w 0 < U) 0 W LL 0O - < 0 D -j te 0 -1 2i z w < z T< a- < OOE U) R W OF:000 oe (If w of < a- w Fie a- n_ CL :E IL u 0 m x Uji a_ LL W < 0 01 a- 0 of w < —i a- 0 0 1112V2020 I of 15 KNA 016A z. 0 Lu LU ca a. 0 w w z F- IL < w LLI LU 0 fL U) z UJ Z Es — — — — — — — — - - - STOQA&! a -ly E, NG SATY EA -6 Aall OF NE:hPDe- E5-(:, DRAB -A� ROr:5 i,-A A AR- Az. R M -L A GOB N6 ' 5"" WOOL / AZR EVE.. = 15 ;5' o,LL AA- T. 0 LA55 555 '.H5 N& 4TG-I 5A5 I., T. 0 AAL- =.51,35: 5-0 rA ... .. .......... . . . ........... . . ------------ ---- REEAR, 'rAR=) LANDSCAPE PLAN/SITE PLAN 3235 Ocean Blvd, Corona Del Mar September 2, 2020 Project No: 72370-10 Red%rLt3PC&0 01§4 PagQ+4:016A 2 building, a 3-foot deep over -excavation and replacement with cement treated compacted fill is recommended in order to provide uniform and adequate foundation support for the structures. The over -excavation should extend 3 feet beyond the footprint of the structures, where practical. Soil cement compacted fill should consist of a mixture of the existing beach deposits material with a minimum of 2 percent cement. The fill should be moisture conditioned and compacted in accordance with the recommendations provided in the referenced reports. The limits of remedial grading are indicated on Figure 1. Item 16: Buildings below slopes shall be set a sufficient distance from the slope to provide protection from slope drainage, erosion and shallow failures. Provide sufficient clearance from toe of slope per CBC 1808.7.1 or provide specific recommendations from geotechnical engineer for how to provide alternate setbacks and clearances in accordance with CBC 1808.7.5. Incorporate email recommendations included in calculations into a stamped and signed letter or addenda from the geotechnical engineer. Response: A caisson -supported debris wall system is recommended behind the proposed pool bath/storage building to provide a debris catchment area and adequate protection from slope drainage, erosion and shallow failures impacting the proposed structure. The debris wall design values were provided in Report 17-8034 dated June 27, 2017, Periodic maintenance behind the debris wall, i.e., cleaning, should be anticipated by the homeowner. As indicated in our updated slope stability analyses presented in Appendix C, the buried pier/caisson system should be designed to resist 2.3 kips per linear foot lateral loading. Caissons utilized for proposed debris wall should be embedded into competent material a minimum depth of 5 feet. Caissons may be designed for a dead plus live load end bearing value of 2,000 pounds per square foot for competent beach deposits. Lateral resistance may be computed utilizing 150 pounds per square foot per foot depth for beach deposits, acting on a tributary area of twice the caisson diameter. Grading/Drainage Plan Review Comments: Item 8: For projects on a slope, adjacent to a slope, with a basement, or project sites which require remedial grading, soils engineer to review and approve the grading plan, foundation plan, and shoring plan (if applicable) to verify that the design is consistent with the geotechnical report recommendations. Soils engineer to stamp . these plans with a review stamp asserting compliance with geotechnical report recommendations. This comment will remain up to and include at the time of permit issuance. Response: Acknowledged. 3235 Ocean Blvd, Corona Del Mar June 27, 2017 Project No: 71879-05 Refi?Zt J&i o 1376fgg4 PagpAJ4=016A 2 Debris Wall must be approved by Coastal Commission Lead Agent. A letter from this Agency must be provided to indicate they have reviewed the location of this wall. Response: Item 3: Based on a meeting at the City of Newport Beach with the reviewer and Mr. Russ Lamb .from Geofirm, recommendations were provided for a debris wall to be located at the garage wall that is parallel to the toe of the slope. Our recommendations were based on an evaluation of the potential surficial instability, thickness of potentially loose soil, setback distance from the toe of the slope, anticipated soil conditions, and our experience on similar projects. Our recommendations included designing a 4-foot high debris wall with a lateral load of 90 pounds per cubic foot equivalent fluid pressure. Coastal commission approval or other approval letters, if required, should be provided by others. Please review the Grading, Foundation and Landscape Plans for compliance with geotechnical recommendations of this report. Response: The plans were reviewed and found to be in general conformance with our geotechnical recommendations. This opportunity to be of service is appreciated. If you have any questions, please call Respectfully submitted, GEOFIRM o`` ERIK R. MILDE , � " �. At No, 2303 ' CERTIFIED � Nc.2565 m ENGINEERING Exp.6/30/18 (P GEOLOGIST Erik R. Hilde, PG C ye"Aldrich, RCE, GE Associate Engineering Geologist, EG 2303 Associate Engineer, GE 2565 Registration Expires 10-31-17 Registration Expires 6-30-18 Date Signed: ERH/EJA: fp Attachments: Appendix A Appendix B Appendix C Distribution: Addressee (5) — References — Geotechnical Report Review Checklist, dated February 16, 2017 — Earth Pressure Load Calculations Project Name/Number: stairs wall3235 Ocean Blvd, Corona bel Mar KNA ENGINEERING, INC. Title Debris Wall at Garage Page: 1 30423 Canwood Street, #223 Dsgnr: AY Date: 20 NOV 2020 ..Agoura Hills, CA 91301 Description.... 11/23/2020 4 of 15 ph: (818) 865-2026 knaeng@pacbell.net KNA14-016A This.Wall in File:. C:\KNA Calc\2014\14-016 Tannir\2020-11-20 Pool Bath Piles\stairs wall.RPX Retainpro (c) 1987-2019, Build 11.20,03.31 License: Kw-06068806 Cantilevered Retaining Wall Code: CBC 2019,ACI 318-14,TMS 402-16 License To: KNA ENGINEERING, INC. Criteria 9 1 Soil Data Retained Height = 5.00 ft Wall height above soil = 0.00 ft Slope Behind Wall = 0.00 Height of Soil over Toe = 9.00 in Water height over heel = 0.0 ft Allow Soil Bearing = 2,500.0 psf Equivalent Fluid Pressure Method Active Heel Pressure = 90.0 psf/ft Passive Pressure = 400.0 psf/ft Soil Density, Heel = 110.00 pcf Soil Density, Toe = 110.00 pcf FootingIlSoil Friction = 0.350 Soil heightto ignore for passive pressure = 0.00 in Lateral Load Applied to Stem Lateral Load = 0.0 #/ft ...Height to Top = 0.00 ft ...Height to Bottom = 0.00 ft Load Type = Wind (W) (Service Level) Wind on Exposed Stem = 0.0 psf (Service Level) Stem Construction Design Height Above Ftc ft = Wall Stability Ratios Wall Material Above "Ht" _ Overturning = 0.90 UNSTABLE! Design Method = Slab Resists All Sliding ! Thickness = Total Bearing Load = 2,400 Ibs ...resultant ecc. = 21.09 in Soil Pressure @ Toe = 0 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,500 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 0 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 0.9 psi OK Footing Shear @ Heel = 6.9 psi OK Allowable = 75.0 psi Sliding Calcs Lateral Sliding Force = 2,205.0 Ibs Rebar Size = Rebar Spacing = Rebar Placed at = Design Data fb/FB + fa/Fa = Total Force @ Section Service Level Ibs = Strength Level Ibs = Moment.... Actual Service Level ft-#= Strength Level ft-# = Moment..... Allowable - Shear ..... Actual Service Level ,psi = Strength Level psi = Shear..... Allowable psi = Anet (Masonry) in2 = Rebar Depth 'd' in = Masonry Data fm psi = Fs psi = Vertical component of active lateral soil pressure IS Solid Grouting = considered in the calculation of soil bearing pressures. Modular Ratio'n' _ Load Factors Building Code CBC 2019,ACI Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic, E 1.000 Bottom Adjacent Footing Load Adjacent Footing Load = 0.0 Ibs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Ftg CL Dist = 0.00 ft Footing Type Line Load Base Above/Below Soil = at Back of Wall 0.0 ft Poisson's Ratio = 0.300 Stem OK 0.00 Concrete LRFD 6.00 # 5 16.00 Edge 0.724 1,800.0 3,000.0 4,142.0 35.8 82.2 4.19 Wall Weight psf = 75.0 Short Term Factor = Equiv. Solid Thick. _ Masonry Block Type =. Medium Weight Masonry Design Method = ASD Concrete Data fc psi = 3,000.0 Fy psi = 60,000.0 Project Name/Number : stairs wall3235 Ocean Blvd, Corona bel Mar KNA ENGINEERING, INC. Title Debris Wall at Garage Page : 2 30423 Canwood Street, #223 Dsgnr: AY Date: 20 NOV 2020 Agoura Hills, CA 91301 Description.... 11/23/2020 5 of 15 ph: (818) 865-2026 knaeng@pacbell.net KNA14-016A This Wall in File: C:\KNA Calc\2014\14-016 Tannir\2020-11-20 Pool Bath Piles\stairs wall.RPX RetainPro (c) 1987-2019, Build 11.20.03.31 License : KW-06058806 Cantilevered Retaining Wall Code: CBC 2019,AC1 318-14,TMS 402-16 License To: KNA ENGINEERING, INC. Concrete Stem Rebar Area Details Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) : 0.1723 in2/ft (4/3) * As: 0.2298 in2/ft Min Stem T&S Reinf Area 0.720 in2 200bd/fy : 200(12)(4.1875)/60000 : 0.1675 in2/ft Min Stem T&S Reinf Area per ft of stem Height: 0.144 in2/ft 0.0018bh : 0.0018(12)(6) : 0.1296 in2/ft Horizontal Reinforcing Options One layer of : Two layers of: Required Area : 0.1723 in2/ft #4@ 16.67 in #4@ 33.33 in Provided Area : 0.2325 in2/ft #5@ 25.83 in #5@ 51.67 in Maximum Area: 0.6807 in2/ft #6@ 36.67 in #6@ 73.33 in Footing Data Footing Design Results Toe Width = 1.25 ft 192 Heel Width = 1.75 Factored Pressure = 0 0 psf Total Footing Width = 3.00 Mu': Upward = 0 0 ft-# Footing Thickness = 24.00 in Mu': Downward = 4,303 1,466 ft-# Mu: Design = -359 1,466 ft-# Key Width = 0.00 in Actual 1-Way Shear = 0.85 6.86 psi Key Depth = 0.00 in Allow 1-Way Shear = 40.00 40.00 psi Key Distance from Toe = 0.00 ft Toe Reinforcing = None Spec'd f'c = 2,500 psi Fy = 60,000 psi Heel Reinforcing = None Spec'd Footing Concrete Density = 150.00 pcf Key Reinforcing = # 5 @ 16.00 in Min, As % = 0.0018 Footing Torsion, Tu = 0.00 ft-Ibs Cover @ Top 2.00 @ Btm = 3.00 in Footing Allow. Torsion, phi Tu = 0.00 ft-Ibs If torsion exceeds allowable, provide supplemental design for footing torsion. Other Acceptable Sizes & Spacings Toe: phiMn = phi'5'lambda'sgrt(fc)'Sm Heel: phiMn = phi'5'lambda'sgrt(fc)'Sm Key: No key defined Min footing T&S reinf Area Min footing T&S reinf Area per foot If one layer of horizontal bars: #4@ 4.63 in #5@ 7.18 in #6@ 10.19 in 1.56 in2 0.52 in2 fit If two layers of horizontal bars: #4@ 9.26 in #5@ 14.35 in #6@ 20.37 in Project Name/Number : stairs wall3235 Ocean Blvd, Corona bel Mar KNA ENGINEERING, INC. Title Debris Wall at Garage Page : 3 30423 Canwood Street, #223 Dsgnr: AY Date: 20 NOV 2020 Agoura Hills, CA 91301 Description.... 11/23/2020 6 of 15 ph: (818) 865-2026 knaeng@pacbell.net KNA14-016A This Wall in File: C:\KNA Calc\2014\14-016 Tannir\2020-11-20 Pool Bath Piles\stairs wall.RPX RetainPro (c) 1987-2019, Build 11.20.03.31 License: KW-06058806 Cantilevered Retaining Wall Code: CBC 2019,AC1 318-14,TMS 402-16 License To: KNA ENGINEERING, INC. Summar of ®verurnin & Resistin Farces M®menu .....OVERTURNING..... .....RESISTING..... Force Distance Moment Force Distance Moment Item Ibs ft ft-# Ibs ft ft-# HL Act Pres (ab water tbl) 2,205.0 2.33 5,145.0 Soil Over HL (ab. water tbl) 687.5 2.38 1,632.8 HL Act Pres (be water tbl) Soil Over HL (bel. water tbl) 2.38 1,632.8 Hydrostatic Force Watre Table Buoyant Force = Sloped Soil Over Hee = Surcharge over Heel = Surcharge Over Heel = Surcharge Over Toe = Adjacent Footing Load = Adjacent Footing Load = Axial Dead Load on Stem= Added Lateral Load = * Axial Live Load on Stem = Load @ Stem Above Soil = Soil Over Toe = 103.1 0.63 64.5 Surcharge Over Toe = Stem Weight(s) = 375.0 1.50 562.5 Earth @ Stem Transitions= Total = 2,205.0 O.T.M. = 5,145.0 Footing Weighl = 900.0 1.50 1,350.0 Key Weight = Resisting/Overturning Ratio = 0.90 Vert. Component = 334.6 3.00 1,003.8 Vertical Loads used for Soil Pressure = 2,400.2 Ibs Total = 2,400.2 Ibs R.M.= 4,613.5 * Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.000 in The above calculation is not valid if the heel soil bearing pressure exgeeds that of the toe because the wall would then tend to rotate into the retained soil Project Name/Number : stairs wall3235 Ocean Blvd, Corona Del Mar KNA ENGINEERING, INC. Title Debris Wall at Garage Page : 4 30423 Canwood Street, #223 Dsgnr: AY Date: 20 NOV 2020 ,Agoura Hills, CA 91301 Description.... 11/23/2020 7 of 15 ph: (818) 865-2026 knaeng@pacbell.net KNA14-016A This Wall in File: C:\KNA Calc\2014\14-016 Tannir\2020-11-20 Pool Bath Piles\stairs wall.RPX Retainpro (c) 1987-2019, Build 11.20.03.31 License : KW-06058806 Cantilevered Retaining Wall Code: CBC 2019,AC1 318-14,TMS 402-16 License To: KNA ENGINEERING, INC. 1P 19-T` 1 11911 3 Project Name/Number: stairs waU 3235 Ocean Blvd, Corona bel Mar KNA ENGINEERING, INC. Title Debris Wall at Garage Page : 5 30423 Canwood Street, #223 Dsgnr: AY Date: 20 NOV 2020 :Agoura Hills, CA 91301 Description.... 11/23/2020 8 of 15 ph: (818) 865-2026 KNA14-016A knaeng@pacbell.net This Wall in File: C:\KNA Calc\2014\14-016 Tannir\2020-11-20 Pool Bath Piles\stairs wall,RPX RetainPro (c) 1987-2019, Build 11.20.03.31 License : KW-06058806 Cantilevered Retaining Wall Code: CBC 2019,AC1 318-14,TMS 402-16 License To: KNA ENGINEERING, INC. 22'05 f-Iorostatic Force Lateral oartli pressure due to the soil BELIJIN water table 3235 Ocean Blvd, Corona Del Mar K N A EGINEERING, INC. Project: job No: q1lillillil'111 NSheet:--- of 11 STRUCTURAL CONSULTANTS 11/23'202n 9,0f_lFi KNA14-4'016A 3 0423CanwoodStreet Sulte223 Agoura Hills, CA91301 • (818)865-2026 ' A -s L -7 4� �el- -I"-! I; KAN ENGINEERING, INC. 30423 Canwood Street Agoura Hills, CA 91301 ph: (818) 865-2026 3235 Ocean Blvd, Corona Del Mar knaeng@pacbell.net 11/23/2020 10 of 15 KNA14-016A Concrete Beam File: 14-016A Pool Software copyright ENERCALC, INC.1983-2020, Build DESCRIPTION: Debris Wall Grade Beam Elastic Modulus = 3,122.0 ksi Fy - Stirrups 40.0 ksi fy - Main Rebar = 60.0 ksi E - Stirrups = 29,000.0 ksi E - Main Rebar = 29,000.0 ksi Stirrup Bar Size # 4 Number of Resisting Legs Per Stirrur = 2 Crass Section & Reinforcing details Rectangular Section, Width = 36.0 in, Height = 24.0 in Span #1 Reinforcing.... 446 at 3.0 in from Bottom, from 0.0 to 16.0 ft in this span 446 at 3.0 in from Top, from 0.0 to 16.0 ft in this span Beam self weight calculated and added to loads Load for Span Number 1 Uniform Load : D = 0.60 k/ft, Tributary Width =1.0 ft DESIGN SUMMARY Maximum Bending Stress Ratio = 0.390 : 1 Maximum Deflection Section used for this span Typical Section Max Downward Transient Deflection 0.000 In Ratio = 0 <360.( Mu : Applied 65.856 k-ft Max Upward Transient Deflection 0.000 In Ratio = 0 <360.( Mn * Phi: Allowable 168.747 k-ft Max Downward Total Deflection 0.017 in Ratio = 11472>=180 Location of maximum on span 7.985 ft Max Upward Total Deflection 0.000 in Ratio = 0 <180.( Span # where maximum occurs Span # 1 Vertical Reactions Support notation : Far left is #1 Load Combination Support 1 Support 2 Overall MAXimum 11,760 11.760 Overall MINimum 7.056 7,056 +D+H 11.760 11.760 +D+L+H 11.760 11.760 +D+Lr+H 11.760 11.760 +D+S+H 11.760 11.760 +D+0.750Lr+0.750L+H 11.760 11.760 +D+0.750L+0.750S+H 11.760 11.760 +D+0.60W+H 11.760 11.760 +D+0.750Lr+0.750L+0.450W+H 11.760 11.760 +D+0.750L+0.750S+0.450W+H 11.760 11.760 +0.60D+0.60W+0.60H 7.056 7.056 +D+0.70E+0.60H 11.760 11.760 KAN ENGINEERING, INC. 30423 Canwood Street Agoura Hills, CA 91301 ph: (818) 865-2026 knaeng@pacbell.net 3235 Ocean Blvd, Corona Del Mar 11/23/2020 11 of 15 KNA14-016A Concrete BeamFile: 016A Pool Bath.ec6 Software copyright ENERCALC, INC. 1983-2020, BuiId:12.20.8.1' KW-06003737 KNA ENGINEERING, INC DESCRIPTION: Debris Wall Grade Beam Vertical Reactions Support notation : Far left is #1 Load Combination Support 1 Support 2 +D+0.750L+0.750S+0.5250E+H 11.760 11.760 +0.60D+0.70E+H 7.056 7.056 D Only 11.760 11.760 H Only Shear Stirrup Requirements Entire Beam Span Length : Vu < PhiVcl2, Req'd Vs = Not Reqd 9.6.3.1, use #4 stirrups spaced at 0.000 in Maximum Forces & Stresses for Load Combinations Load Combination Location (ft) Bending Stress Results ( k-ft ) Segment Span # alono Beam Mu: Max Phi*Mnx Stress Ratio MAXimum BENDING Envelope Span # 1 +1.40D+1.60H Span # 1 +1.20D+0.50Lr+1.60L+1.60H Span # 1 +1.20D+1.60L+0.50S+1.60H Span # 1 +1.20D+1.60Lr+L+1.60H Span # 1 +1.20D+1.60Lr+0.50W+1.60H Span # 1 +1.20 D+L+1.60 S+1.60 H Span # 1 +1.20D+1.60S+0.50W+1.60H Span # 1 +1.20D+0.50Lr+L+W+1.60H Span # 1 +1.20 D+L+0.50S+W+1.60 H Span # 1 +0.90D+W+1.60H Span # 1 +1.20D+L+0.20S+E+1.60H Span # 1 +0.90D+E+0.90H Span # 1 Overall Maximum Deflections 1 16.000 65.86 168.75 0.39 1 16.000 65.86 168.75 0.39 1 16,000 56.45 168.75 0.33 1 16.000 56.45 168.75 0.33 1 16.000 56.45 168.75 0.33 1 16.000 56.45 168.75 0.33 1 16.000 56.45 168.75 0.33 1 16.000 56.45 168.75 0.33 1 16.000 56.45 168.75 0.33 1 16.000 56.45 168.75 0.33 1 16.000 42,34 168.75 0.25 1 16.000 56.45 168.75 0.33 1 16.000 42.34 168.75 0.25 Load Combination Span Max. "-" Defl (in) Location in Span (ft) Load Combination Max. "+" Defl (in) Location in Span (ft) D Only 1 0.0167 8.000 0.0000 0.000 KAN ENGINEERING, INC. 30423 Canwood Street Agoura Hills, CA 91301 Kph: (818) 865-2026 knaeng@pacbell.net Pale Footing Embedded in Soil DESCRIPTION: Caisson Embedment Code References Calculations per IBC 2018 1807.3, CBC 2019, ASCE 7-16 Load Combinations Used : ASCE 7-16 General Information Pole Footing Shape Circular Pole Footing Diameter ........... 36.0 in Point Load Calculate Min. Depth for Allowable Pressures No Lateral Restraint at Ground Surface Allow Passive .................. 300.0 pcf Max Passive ................. . . 1,500.0 psf Distributed LoadS Controlling Values Governing Load Combination : +D+H Lateral Load 29.50 k Moment 161.950 k-ft NO Ground Surface Restraint Pressures at 1/3 Depth Actual 1,500.0 psf Allowable 1,500.0 psf Footing Base Area 7.069 ft^2 Maximum Soil Pressure 0.0 ksf Anolied Loads 3235 Ocean Blvd, Corona Del Mar 11/23/2020 KNA14-016A HE 12 of 15 ), Build:12.20.8.1' M J estrahq- Lateral Concentrated Load (k) Lateral Distributed Loads (klf) Vertical Load (k) D : Dead Load k k/ft k Lr ; Roof Live k k/ft k L ; Live k k/ft k S : Snow k k/ft k W : Wind k k/ft k E ; Earthquake k k/ft k H ; Lateral Earth 18.0 k 2.30 k/ft k Load distance above TOP of Load above ground surface ground surface 7.40 ft 5.0 ft BOTTOM of Load above ground surface ft " Load Combination Results +D+H 29.500 161.950 20.00 1,500.0 1,500.0 1.000 +D+L+H 29.500 161.950 20.00 1,500.0 1,500.0 1.000 +D+Lr+H 29.500 161.950 20.00 1,500.0 1,500.0 1.000 +D+S+H 29.500 161.950 2.0.00 1,500.0 1,500.0 1.000 +D+0.750Lr+0.750L+H 29.500 161,950 20.00 1,500.0 1,600.0 1.000 +D+0.750L+0.750S+H 29.500 161.950 20.00 1,500.0 1,500.0 1.000 +D-+0.60W+H 29.500 161.950 20.00 1,500.0 1,500.0 1.000 +D+0.750Lr+0.750L+0.450W+H 29.500 161.950 20.00 1,500.0 1,500.0 1.000 +D+0.750L+0.750S+0.450W+H 29.500 161.950 20.00 1,500.0 1,500.0 1.000 KAN ENGINEERING, INC. 3235 Ocean Blvd Corona Del Mar 30423 Canwood Street j Agoura Hills, CA 91301 j ph: (818) 865-2026 knaeng@pacbell,net 11/23/2020 13 of 15 KNA14-016A ��p� �{'Jta'��t"t EiY9��dd�' Itl ��1� File: 14-0 6A Pool Bath:ec6 Software copyright ENERCALC, INC:1983-2020, BuiId:12.20,8.1 DESCRIPTION: Caisson Embedment +0.60D+0.60W+0.60H 17.700 97.170 14.13 1,402.6 1,403.9 1,000 +D+0.70E+0,60H 17.700 97A70 14.13 1,402.6 1,403.9 1,000 +D+0.750L+0.750S+0.5250E+H 29.500 161.950 20.00 1,500.0 1,500.0 1.000 +0.60D+0.70E+H 29.500 161.950 20.00 1,500.0 1,500.0 1,000 KAN ENGINEERING, INC. 30423 Canwood Street Agoura Hills, CA 91301 ph: (818) 865-2026 knaeng@pacbell.net Concrete Column DESCRIPTION: PILE REINFORCMENT Code References Calculations per ACI 318-14, IBC 2018, CBC 2019, ASCE 7-16 Load Combinations Used : ASCE 7-16 General Information 3235 Ocean Blvd, Corona Del Mar 11/23/2020 14 of 15 KNA14-016A Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.1' fc : Concrete 28 day strength = 3 ksi Overall Column Height = 12.0 ft E _ = 3122 ksi End Fixity Top Free, Bottom Fixed Density = 150 pcf Brace condition for deflection (buckling) along columns (3 = 0.0 X-X (width) axis: fy - Main Rebar = 60 ksi Fully braced against buckling ABOUT Y-Y Axis E - Main Rebar = 29000 ksi Y-Y (depth) axis : Allow. Reinforcing Limits ASTMA615 Bars Used Fully braced against buckling ABOUT X-X Axis Min. Reinf. = 1 0/0 Max. Reinf. = 8 % Column Cross Section Column Dimensions: 36.Oin Diameter, Column Edge to Rebar Edge Cover = 3.50in Column Reinforcing : 14 - #8 bars I Applied Loads Entered loads are factored per load combinations specified by user. Column self weight included : 12,723.5 Ibs * Dead Load Factor BENDING LOADS ... Lat. Point Load at 7.40 ft creating Mx-x, H =18.0 k Lat. Uniform Load from 0.0->5.0 ft creating Mx-x, H = 2.30 k/ft DESIGN SUMMARY Load Combination 0.0 Maximum SERVICE Load Reactions.. Location of max.above base 0.0 ft Top along Y-Y 0.0 k Bottom along Y-Y 0.0 k Maximum Stress Ratio 0.0 : 1 Top along X-X 0.0 k Bottom along X-X 0.0 k Ratio = (Pu"2+Mu^2)".5 / (PhiPnA2+PhiMnA2)^.5 Pu= 0.0 k cp *Pn= 0.0k Mu-x = 0.0 k-ft tp * Mn-x = 0.0 k-ft Maximum SERVICE Load Deflections ... Mu-y = 0.0 k ft * Mn y = 0.0 k ft Along Y-Y 0.0 in at 0.0 ft above base for load combination : 0.o Mu Angle = 0.0 deg Along X-X O.Oin at O.Oft above base Mu at Angle = 259.120 k-ft qMn at Angle = 665.87 k-ft for load combination . o.o Pn & Mn values located at Pu-Mu vector intersection with capacity curve Column Capacities ... General Section Information . = 0.0 =0.0 0 = n n Pnmax : Nominal Max. Compressive Axial Capacity 0.0 k p %Reinforcing 0.0 % Rebar < Min of 1.0 Pnmin : Nominal Min. Tension Axial Capacity k Reinforcing Area 0.0 inA2 cp Pn, max: Usable Compressive Axial Capacity 0.0 k Concrete Area 0.0 in12 tp Pn, min : Usable Tension Axial Capacity k Governina Load Combination Results Governing Factored Moment Dist. from Axial Load Bending Analysis k-ft Load Combination k * Utilization X-X Y-Y base ft Pu rp Pn 5x gx* Mux gy 5y* Muy Alpha (deg) 8 Mu (p Mn Ratio KAN ENGINEERING, INC, 3235 Ocean Blvd, Corona bel Mar 30423 Canwood Street Agoura Hills, CA 91301 Ph: (818) 865-2026 knaeng@pacbell,net 11/23/2020 15 of 15 KNA14-016A �CAil�l"��£ �®fUli1'd11 File: 4-0 6APoolBath:ec6 Sofiware copyrightfNERCALC, INC.1983-P020, BuiId:12,20:8.1' r.rr DESCRIPTION: PILE REINFORCMENT Maximum Reactions Note: Only non -zero reactions are listed. X-X Axis Reaction k Y-Y Axis Reaction Axial Reaction My - End Moments k-ft Mx - End Moments Load Combination @ Base @ Top @ Base @ Top @ Base @ Base @ Top @ Base @ Top Maximum Moment Reactions Note: Only non -zero reactions are listed. Moment About X-X Axis Moment About Y-Y Axis Load Combination @ Base @ Top @ Base @ Top Sketches �) KeA ENGINEERING, INC. S Tf 3 �_ J f�C C7 h� I. T A h*1 h J 30423 Carrwc>cad �itrer. k Suite1.2 � • ��cxa, �z I hllti. CA91 301 (ts I f3) t��, i 2026 ff�X ((31 t� ) i3(i , 1889 STRUCTURAL CALCULATIONS Pool Bath Plan Check For KNA 14-016A 3235 Ocean Boulevard Corona Del Mar, CA DATED 8/ 19/2020 PAGES 1 to 17 8/ 17/20 �,�meFgs ��ca.ironnm r 3235 Oc an n � � r KNA 14-0 A 9/2 2 3 of 17 Ocean Blvd, Newport Beach, CA 92625, USA Latitude, Longitude: 33.5942958,-117.8741916 F Vl _ Lookout Paint' Fuse Bakery C,af� °la� e2'"� u�� UnitedStatesar Carona del M°���, �;��a y� Postal Service Municipal Lot Corona del Mar State (eaaia ���ar Go. gle Date 8/19/2020, 10:31:52 AM Design Code Reference Document ASCE7-16 Risk Category II Site Class D - Default (See Section 11.4.3) Type Value Description SS 1.359 MCER ground motion. (for 0.2 second period) SI 0.482 MCER ground motion. (for 1.0s period) SMS 1.63 SMi null -See Section 11.4 SDS 1.087 j SDI null -See Section 11.4 Type Value SDC null -See Section 11.4.8 Fa 1.2 F null -See Section 11.4.8 PGA 0.594 FPGA 1.2 PGAM 0.713 TL 8 SsRT 1.359 SsLJH 1.496 SsD 2.629 S 1 RT 0.482 S1L1H 0.523 S1D 0.82 PGAd 1.058 CRS 0.908 CR1 0.921 Site -modified spectral acceleration value .8 Site -modified spectral acceleration value Numeric seismic design value at 0.2 second SA .8 Numeric seismic design value at 1.0 second SA Description Seismic design category Site amplification factor at 0.2 second Site amplification factor at 1.0 second MCEG peak ground acceleration Site amplification factor at PGA Site modified peak ground acceleration Long -period transition period in seconds Probabilistic risk -targeted ground motion. (0.2 second) Factored uniform -hazard (2% probability of exceedance in 50 years) spectral acceleration Factored deterministic acceleration value. (0.2 second) Probabilistic risk -targeted ground motion. (1.0 second) Factored uniform -hazard (2% probability of exceedance in 50 years) spectral acceleration. Factored deterministic acceleration value. (1.0 second) Factored deterministic acceleration value. (Peak Ground Acceleration) Mapped value of the risk coefficient at short periods Mapped value of the risk coefficient at a period of 1 s 3235 Ocean Blvd, Corona Del Mar KNA 14-016A 8/19/2020 2 of 17 ROOF DIAPHRAGM 3235 Ocean Blvd, Corona bel Mar KNA 14-016A 8/19/2020 3 of 17 Seismic Analysis Based on IBC 12 / CBC 13 (Equivalent lateral -Force Procedure, ASCE 7-10 12.8) CS max.= SDI Ta=Ct(hn)075 1= 1.0 T(R/1) = 0.02x 11 0.75 R= 6.5 = 0.614 = 0.121 < 0.5 Z= 0.4 > k = 1 hn= 11 Occupancy Category: I[ Ss= 1.359 Site class: D SI= 0.482 Seismic design category: D Fa= 1.20 Latitude: - Fv= 1.50 Longitude: - SMs= (Fa)(Ss)= 1.631 Redundancy Factor p : 1.3 SDS= 2/3(SMs)= 1.087 SM1= (Fv)(SI)= 0.723 SDI= 2/3(SM1)= 0,482 CS = SDS (R/1) = 0.167 0.167 use CS MIN.= 0.01 WHEN SI< 0.6 CS MIN.= 0.5S1 WHEN S1> 0,6 (R/1) 0.0371 Seismic Factor= 0.167 /1.4 = 0.119 Total Base Shear V = 8,988 X 0.119 = 1074 lb = 1 kips (ASD) x 1.3 = 1 kips 3235 Ocean Blvd, Corona bel Mar KNA 14-016A 8/19/2020 4 of 17 0 ROOF DIAPHRAGM Area sq.ft 1 14.0 x 11.0 = 154 E 154 SQ.FT Trellis F = 10'x16'/2x5psfx0.119 = 48 lb Unit load psf lb x 6.97 = 1,074 3235 Ocean Blvd, Corona Del Mar KNA 14-016A 8/19/2020 5 of 17 SEISMIC LOAD ROOF DL: 154 Sq.Ft x 22 psf = 3,388 EXT. WALL: 50'x 5.0'x 18 psf= 4,500 I NT. WALL: 20 'x 5.0 'x 11 psf = 1,100 E 8,988 x 0.119 = 1,074 ROOF DL LEVEL H DL DLxH DLxH F Dist. Load Area Unit Load ROOF 11.0 1,074 11,812 1.000 ' 1,074 154 6.97 E 1,074 E 11,812 3235 Ocean Blvd, Corona bel Mar KNA 14-016A 8/19/2020 6 of 17 SHEAR WALLS FROM ROOF TO 2ND FLOOR LINE 1 AREA F = 0.50 x 1 F = 0.50 x 1074 F = 537 lb x 1.3 = 698 lb P L = 13.5 L = 13.5 ft V = 698 / 13.5__..._.___._._____._._____.._._._.._� V = 52 plf + (0.6-0.14SoS) WALL HT WALL WT WALL HT ROOF WT ROOF SPAN �/ WALL LENGTH HD = 52 x 10 -( 18 x 10 + 22 x 1 )x 0.45 x 14 / 2 HD = -116 lb TYPE 2A NO HD Req'd LINE 2 AREA TRELLIS F = 0.50 x 1 + 1.00 x 48 F = 0.50 x 1074 + 1.00 x 48 F = 585 lb x 1.3 = 760 lb P L= 7 L = 7 ft V = 760 / 7 V = 109 plf WALL HT WALL WT WALL HT ROOF WT ROOF SPAN WALL LENGTH HD = 109 x 10 -( 18 x 10 + 22 x 1 )x 0.45 x 7 / 2 HD = 770 lb TYPE 2A HDU2 3235 Ocean Blvd, Corona bel Mar KNA 14-016A 8/19/2020 7 of 17 SHEAR WALLS FROM ROOF TO 2ND FLOOR LINE A AREA TRELLIS F = 0.50 x 1 + 1.00 x 48 F = 0.50 x 1074 + 1.00 x 48 F = 585 lb x 1:69 = 988 lb 1.3px1.3 Orthognal Effect L= 5 L = 5 ft V = 988 / 5 V = 198 plf ° (0.6-0.14Sos) WALL HT WALL WT WALL HT ROOF WT ROOF SPAN �/ WALL LENGTH HD = 198 x - 10 -( 18 x 10 + 22. x 5 )x 0.45 x. 5 / 2 HD = 1,652 lb TYPE 2A HDU2 LINE B AREA TRELLIS F = 0.51 x 1 + 1.00 x 48 F = 0.51 x 1074 + 1.00 x 48 F = 596 lb x 1.3 = 774 lb P L= 4 L= 4ft H/W=10/4=2.5<3.45OK V= 774 /4 2W / H = 2x4 / 10 = 0.80 1A Capacity = 280xO.80 = 224 PLF V = 194 plf WALL HT WALL WT WALL HT ROOF WT ROOF SPAN WALL LENGTH HD = 194 x 10 -( 18 x 10 + 22 x 5 )x 0.45 x 4 / 2 HD = 1,676 lb TYPE 2A HDU2 1 i II II 3235 Ocean Blvd, Corona Del Mar II I< N A ENGINEERING, INC. Project: Sheet:._ STRUCTURAL CONSULTANTS Client: _ By: Date: 30423 Canwood Street Suite 223 • Agoura Hills, CA 91301 • (818) 865-2026 KAN ENGINEERING, INC. 3235 Ocean Blvd, Corona Del Mar 30423 Canwood Street KNA 14-016A 8/19/2020 9 of 17 Agoura Hills, CA 91301 ph; (818) 865-2026 knaeng@pacbell.net t��, ColumnFile: 14-016APoo Bath.ec6 Software copyright ENERCALC, INC.1983-2020, Build:12.20.8.1 DESCRIPTION: TRELLIS COLUMN Code References Calculations per AISC 360-10, IBC 2015, CBC 2016, ASCE 7-10 Load Combinations Used : ASCE 7-16 General Information Steel Section Name : Pipe3STD Overall Column Height 10.0 ft Analysis Method ; Load Resistance Factor Top & Bottom Fixity Top Free, Bottom Fixed Steel Stress Grade Brace condition for deflection (buckling) along columns Fy : Steel Yield 35.0 ksi X-X (width) axis E : Elastic Bending Modulus 2.9,000.0 ksi Fully braced against buckling ABOUT Y-Y Axis Y-Y (depth) axis Filly braced against buckling ABOUT X-X Axis DDlied Loads Column self weight included : 75.80 Ibs * Dead Load Factor AXIAL LOADS ... Axial Load at 10.0 ft, D = 0.10 k BENDING LOADS , . . Lat. Point Load at 10.0 ft creating Mx-x, E = 0.2870 k DESIGN SUMMARY Bending & Shear Check Results PASS Max, Axial+Bending Stress Ratio = Load Combination Location of max.above base At maximum location values are ... Pu 0.9 * Pn Mu-x 0.9*Mn-x: Mu-y 0.9*Mn-y: PASS Maximum Shear Stress Ratio = Load Combination Location of max.above base At maximum location values are ... Vu : Applied Vn * Phi : Allowable Load Combination Results Load Combination +1.40D+1.60H +1.20 D+0.50 Lr+1.60 L+1.60 H +1.20 D+1.60 L+0.50S+1.60 H +1.20 D+1.60 Lr+L+1.60 H +1.20 D+1.60 Lr+0.50 W+1.60 H +1.20 D+L+1.60 S+1.6 0 H +1.20 D+1.60 S+0.50 W+1.60 H +1.20 D+0.5 O L r+L-t-W+1.6 0 H +1. 20 D+L+0 , 50 S+W+1. 6 0 H +0.90D+W+1.60H +1.20D+L+0.20S+E+1.60H +0.90D+E+0.90H Maximum Reactions Load Combination 0.5009 +1.20 D+L+0.20 S+E+ 1.60H 0.0 ft 0.2110 k 65.205 k -2.870 k-ft 5.749 k-ft 0.0 k-ft 5.749 k-ft 0.01761 : 1 +1.20D+L+0.20S+E+ 1.60 H 0.0 ft 0.2870 k 16,301 k Service loads entered. Load Factors will be applied for calculations. Maximum Load Reactions, . Top along X-X Bottom along X-X Top along Y-Y Bottom along Y-Y Maximum Load Deflections ... Along Y-Y 1.990 in at for load combination :E Only Along X-X 0.0 in at for load combination : 0.0 k 0.0 k 0.0 k 0.2870 k 10.0ft above base O.Oft above base Maximum Axial + Bending Stress Ratio Status Stress Ratios Location Cbx Cby KxLx/Rx KyLy/Ry Maximum Shear Ratios Stress Ratio Status Location 0.004 PASS 0.00 ft 1.00 1.00 0.00 0.00 0.000 PASS 0.00 ft 0.003 PASS 0.00 ft 1.00 1.00 0.00 0.00 0.000 PASS 0.00 ft 0.003 PASS 0.00 ft 1.00 1.00 - 0.00 0.00 0.000 PASS 0.00 ft 0.003 PASS 0.00 ft 1.00 1.00 0.00 0.00 0.000 PASS 0.00 ft 0.003 PASS 0.00 ft 1.00 1.00 0.00 0.00 0.000 PASS 0.00 ft 0.003 PASS 0.00 ft 1.00 1.00 0.00 0.00 0.000 PASS 0.00 ft 0.003 PASS 0.00 ft 1.00 1.00 0.00 0.00 0.000 PASS 0.00 ft 0.003 PASS 0.00 ft 1.00 1.00 0.00 0.00 0.000 PASS 0.00 ft 0.003 PASS 0.00 ft 1.00 1.00 0.00 0.00 0,000 PASS 0.00 ft 0,002 PASS 0.00 ft 1.00 1.00 0.00 0.00 0.000 PASS 0.00 ft 0.501 PASS 0.00 ft 1.00 1.00 0.00 0.00 0.018 PASS 0.00 ft 0.500 PASS 0.00 ft 1.00 1.00 0.00 0.00 0,018 PASS 0.00 ft Note: Only non -zero reactions are listed. Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction Mx - End Moments k-ft My - End Moments @ Base @ Base @ Top @ Base @ Top @ Base @ Top @ Base @ Top +D+H 0.176 KEN ENGINEERING, INC. 3235 Ocean Blvd, Corona Del Mar 30423 Canwood Street KNA 14-016A 8/19/2020 10 of 17 Agoura Hills, CA 91301 ph: (818) 865-2026 knaeng@pacbell,net File: -016A Pool Bath.ec6 Software copyright ENERGALC, INC.1983-2020, BuiId:12,20.8;1 DESCRIPTION; TRELLIS COLUMN Maximum Reactions Note: Only non -zero reactions are listed. Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction Mx - End Moments k-ft My - End Moments Load Combination @ Base @ Base @ Top @ Base @ Top @ Base @ Top @ Base @ Top +D+L+H 0.176 +D+Lr+H 0,176 +D+S+H 0.176 +D+0.750Lr+0,750L+H 0.176 +D+0,750L+0.750S+H 0.176 +D+0,60W+H 0.176 +D+0.750Lr+0.750L+0.450W+H 0,176 +D+0.750L+0.750S+0.450W+H 0.176 +0.60D+0.60W+0.60H 0.105 +D+0.70E+0.60H 0.176 0.201 -2.009 +D+0.750L+0.750S+0.5250E+H 0.176 0.151 -1.507 +0.60D+0,70E+H 0.105 0.201 -2.009 D Only 0.176 Lr Only L Only S Only W Only E Only 0,287 -2.870 H Only Extreme Reactions Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction Mx - End Moments k-ft My - End Moments Item Extreme Value @ Base @ Base @ Top @ Base @ Top @ Base @ Top @ Base @ Top Axial @ Base Maximum 0.176 " Minimum Reaction, X-X Axis Base Maximum 0,176 " Minimum 0.176 Reaction, Y-Y Axis Base Maximum 0,287 -2.870 " Minimum 0.176 Reaction, X-X Axis Top Maximum 0.176 " Minimum 0.176 Reaction, Y-Y Axis Top Maximum 0.176 " Minimum 0,176 Moment, X-X Axis Base Maximum 0.176 " Minimum -2.870 0.287 -2.870 Moment, Y-Y Axis Base Maximum 0.176 " Minimum 0.176 Moment, X-X Axis Top Maximum 0.176 " Minimum 0.176 Moment, Y-Y Axis Top Maximum 0.176 " Minimum 0.176 Maximum Deflections for Load Combinations Load Combination Max. X-X Deflection Distance Max. Y-Y Deflection Distance +D+H 0.0000 in 0.000 ft 0.000 in 0.000 ft +D+L+H 0.0000 in 0.000 ft 0.000 in 0.000 ft +D+Lr+H 0.0000 in 0.000 ft 0.000 in 0.000 ft +D+S+H 0.0000 in O.00Q ft 0.000 in 0,000 ft +D+0.750Lr+0.750L+H 0.0000 in 0.000 ft 0.000 in 0.000 ft +D+0,750L+0.750S+H 0.0000 in 0,000 ft 0.000 in 0.000 ft +D+0,60W+H 0.0000 in 0.000 ft 0.000 in 0.000 ft +D+0.750Lr.+0.750L+0.450W+H 0.0000 in 0.000 ft 0.000 in 0.000 ft +D+0.750L+0,750S+0.450W+H 0.0000 in 0.000 ft 0,000 in 0.000 ft +0,60D+0.6OW+0.60H 0.0000 in 0.000 ft 0,000 in 0,000 ft +D+0.70E+0.60H 0.0000 in 0.000 ft 1.393 in 10.000 ft +D+0,750L+0.750S+0.5250E+H 0.0000 in 0.000 ft 1.045 in 10.000 ft +0.60D+0.70E+H 0.0000 in 0.000 ft 1.393 in 10.000 ft D Only 0.0000 in 0.000 ft 0.000 in 0.000 ft Lr Only 0.0000 in 0.000 ft 0.000 in 0.000 ft KAN ENGINEERING, INC. 3235 Ocean Blvd, Corona Del Mar 30423 Canwood Street KNA 14-016A 8/19/2020 11 of 17 Agoura Hills, CA 91301 Rh: (818) 865-2026 knaeng@pacbell.net Steel Column File: - A Pool Bath.ec6 Software copyright ENERCALC, INC.1983-2020, Build: 12.20.8,1 DESCRIPTION: TRELLIS COLUMN Maximum Deflections for Load Combinations Load Combination Max. X-X Deflection Distance Max. Y-Y Deflection Distance L Only 0.0000 in 0.000 ft 0,000 in 0.000 ft S Only 0.0000 in 0,000 ft 0.000 In 0,000 ft W Only 0.0000 in 0.000 ft 0.000 in 0,000 ft E Only 0.0000 in 0.000 ft 1.990 in 10.000 ft H Only 0,0000 in 0.000 ft 0,000 in 0,000 ft Steel Section Properties : Pipe3STD Depth = 3.500 in I xx = 2.85 in14 J = 5.690 in14 S xx = 1.63 inA3 Diameter = 3.500 in Rxx = 1,170 in Wall Thick = 0.216 in Zx = 2.190 inA3 Area = 2.070 inA2 lyy = 2.850 inA4 Weight = 7,580 plf S yy = 1.630 inA3 R yy = 1.170 in Ycg = 0.000 in 3235 Ocean Blvd, Corona bel Mar KNA 14-016A 8/19/2020 12 of 17 �+71►'�I:i+'i•JC■ Anchor Designer TM Software Version 2.8.7094.1 1.Proiect information Customer company: Customer contact name: Customer e-mail: Comment: 2. Input Data & Anchor Parameters General Design method:ACI 318-14 .Units: Imperial units Anchor Information: Anchor type: Cast -in -place Material: AB Diameter (inch): 0.500 Effective Embedment depth, hef (inch): 12.000 Anchor category: - Anchor ductility: Yes hmin (Inch): 13.88 Cmin (Inch): 3.00 Smin (Inch): 3.00 Company: Date: 8/19/2020 Engineer: Page: 1/6 Project: Address: Phone: E-mail: Recommended Anchor Anchor Name: PAB Pre -Assembled Anchor Bolt - PAB4 (1/2" 0) Project description: Location: Fastening description: Base Material Concrete: Normal -weight Concrete thickness, h (inch): 48.00 State: Cracked Compressive strength, f'. (psi): 3000 4J",v: 1.2 Reinforcement condition: A tension, A shear Supplemental reinforcement: Not applicable Reinforcement provided at corners: Yes Ignore concrete breakout in tension: No Ignore concrete breakout in shear: No Ignore 6do requirement: No Build-up grout pad: Yes Base Plate Length x Width x Thickness (inch) Yield stress: 36000 psi Profile type/size: Pipe3STD 4.00 x 15.00 x 0.75 Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com 3235 Ocean Blvd, Corona bel Mar KNA 14-016A 8/19/2020 13 of 17 E-71►�n�--�•J►■ Anchor DesignerTM . , Software Version 2.8.7094.1 Load and Geometry Load factor source: ACI 318 Section 5.3 Load combination: U = 0.9D + 1.0E Seismic design: Yes Anchors subjected to sustained tension: Not applicable Ductility section for tension: not satisfied Ductility section for shear: not satisfied Do factor: 2.5 Apply entire shear load at front row: No Anchors only resisting wind and/or seismic loads: Yes Company: I Date: 8/19/2020 Engineer: I Page: 2/6 Project: Address: Phone: E-mail: Service level loads: D E Strength level loads Na [lb]: 330 0 297 Vax [lb]: 0 0 0 Vay [lb]: 287 0 258 Mx [ft-lb]: 2870 0 2583 My [ft-lb]: 0 0 0 Mz [ft-lb]: 0 0 0 <Figure 1> Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Po' itas Boulevard Pleasanton, CA 94688 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com 3235Ocean Blvd, Corona Da|Mar Anchor Designer nw ' Software Version 2.8.7094.1 ^Figure 2> ' Company: I Date: 8/19/2020 Engineer: I Page: 13/6 Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. sosavuLas pvommBoulevard Pleasanton, o^n*noo pvvne:oos.ono.00uo mm:o25.o*r.om1 www.stnnnoo.nnm 3235 Ocean Blvd, Corona bel Mar KNA 14-016A 8/19/2020 15 of 17 imrwnAnchor Designer �{Software �kVersion 2.8.7094.1 0 Company: I Date: 8/19/2020 Engineer: I Page: 4/6 Project: Address: Phone: E-mail: 3. Resulting Anchor Forces Anchor Tension load, Shear load x, Shear load y, Shear load combined, % (lb) Vuax (lb) Way (lb) q(Vuax)z+(Vuay)Z (lb) 1 0.0 0.0 64.5 64.5 2 195.9 0.0 64.5 64.5 3 1194.9 0.0 64.5 64.5 4 1694.4 0.0 64.5 64.5 Sum 3085.3 M Maximum concrete compression strain (%o): 0.10 Maximum concrete compression stress (psi): 419 Resultant tension force (lb):3085 Resultant compression force (lb): 2788 Eccentricity of resultant tension forces in x-axis, e'Nx (inch): 0.00 Eccentricity of resultant tension forces in y-axis, e'Ny (inch): 2.27 Eccentricity of resultant shear forces in x-axis, e'vx (inch): 0.00 Eccentricity of resultant shear farces in y-axis, e'vy (inch): 0.00 4. Steel Strength of Anchor in Tension (Sec. 17.4.1� Ns,, (Ib) 0 &sa (lb) 8235 0.75 6176 5. Concrete Breakout Strength of Anchor in Tension (Sec. 17.4.2) Nb = 16Aa4fch.i 13 (Eq. 17.4.2.2b) Aa fo (psi) her (In) Nb (lb) 1.00 3000 12.000 55121 258.0 258.0 <Figure 3> Y 0.750Ncbg =0.750 (ANc/ANco) Iec,NY%d,NYJc,NV'cp,NNb (Sec. 17.3.1 &. Eq. 17.4.2.1b) ANc (Inz) ANco (Inz) Ca,mfn (In) Y'ec,N P'ed,N y'c,N :'cp,N Nb (lb) 0 0.75ON09 (Ib) 279.00 1296.00 3.00 0.888 0.750 1.00 1.000 55121 0.75 4446 6. Pullout Strength of Anchor in Tension (Sec. 17.4.3) 0.750Npn = 0.750'I1c,PNp = 0.750VfcP8AbrgFc (Sec. 17.3.1, Eq. 17.4.3.1 & 17.4.3.4) V'o,P Abrg (Inz) fc (psi) 0 0.750Np,, (lb) 1.0 1.57 3000 0.70 19795 Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com 3235 Ocean Blvd, Corona bel Mar KNA 14-016A 8/19/2020 16 of 17 l+'71►41s+7•J►■ Anchor DesignerTM Software Version 2.8.7094.1 Company: Date: 8/19/2020 Engineer: Page: 5/6 Project: Address. - Phone: E-mail: 7. Side -Face Blowout Strength of Anchor in Tension (Sec. 17.4.4) 0.750Nsbg = 0.75¢{(1+Ca2/Ca1)/4}(1+s/6Ca1)Nsb = 0.750((1+Ca2/Cai)/4)(1+s/6ca1)(160Ca14Abrg)A4f'c (Sec. 17.3.1, Eq. 17.4.4.1 & 17.4.4.2) s (in) Cal (in) cat (in) Abrg (in2) Aa f'o (psi) 0 0.750Nsb (lb) 9.00 3.00 99999.00 1.57 1.00 3000 0.75 27804 8. Steel Strength of Anchor in Shear (Sec. 17.5.1) Vsa (Ib) 09rout 0 091outroVsa (lb) 4940 0.8 0.65 2569 9. Concrete Breakout Strength of Anchor in Shear (Sec. 17.5.2) Shear parallel to edge in y-direction: Vbx = min17(/e/da)0"4daria4fXa1"-'; 9%a4fcca11'11 (Eq. 17.5.2.2a & Eq. 17.5.2.2b) k (in) da (In) Aa fo (psi) cal (in) Vbx (Ib) 4.00 0.500 1.00 3000 3.00 2135 OVcbgy = 0(2)(Avc/Avco)Yeo,vVedvVcvy1B,vVbx (Sec. 17.3.1, 17.5.2.1(c) & Eq. 17.5.2.1b) Avc (in2) Avco (in2) Wea,V Ved,V tl'e,V V',,,v Vbx (Ib) 0 oVcbgy (lb) 94.50 40.50 1.000 1.000 1.200 1.000 2135 0.75 8968 10. Concrete Pryout Strength of Anchor in Shear (Sec. 17.5.3) OVcpg = OkcpNcbg = okcp(ANc7ANco)T'ec,NY'ed,NT'cNT'cp,NNb(Sec. 17.3.1 & Eq. 17.5.3.1b) kcp ANc (In2) ANco (In2) Tec,N Ved,N 1'qN Top,N Nb (lb) 0 OVcpg (lb) 2.0 297.00 1296.00 1,000 0.750 1.000 1.000 55121 0.70 13263 11. Results Interaction of Tensile and Shear Forces (Sec. 17.6. Tension Factored Load, Nua (lb) Steel 1694 Concrete breakout 3085 Pullout 1694 Side -face blowout 3085 Design Strength, M (lb) Ratio 6176 0.27 4446 0.69 19795 0.09 27804 0.11 Status Pass Pass (Governs) Pass Pass Shear Factored Load, Vua (lb) Design Strength, oVn (lb) Ratio Status Steel 65 2569 0.03 Pass 11 Concrete breakout x- 258 8968 0.03 Pass (Governs) Pryout 258 13263 0.02 Pass Interaction check Nua/ONn VualoVn Combined Ratio Permissible Status Sec. 17.6..1 0.69 0.00 69.4% 1.0 Pass PA134 (1/2" 0) with hef = 12.000 inch meets the selected design criteria. Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com 3235 Ocean.Blvd, Corona bel Mar KNA 14-016A 8/19/2020 17 of 17 E-�1►�n:.��•�►■ Anchor Designerr"" e , Software Version 2.8.7094.1 Base Plate Thickness Required base plate thickness: 0.741 inch Company: Date: 8/19/2020 Engineer: Page: 6/6 Project: Address: Phone: E-mail: 12. Warnings - Designer must exercise own judgement to determine if this design is suitable. Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com I Z eM - -2 C) -ZC) is KNA ENGINEERING, INC. I WJ(- I (JKAL (--(-)N:)tJl- I AN 1'-) 11019 STRUCTURAL CALCULATIONS ITEM Loading Roof Framing Lateral Analysis Foundation Trellis Beams Trellis La--�---ral BUILDING DIVISION OCT 6 2020 W. M-K Pool Bath For KNA 14-016A 3235 Ocean Boulevard Corona Del Mar, CA DATED 5/27/2020 PAGES I to 37 TOM. 2 wu0moomw" 7 16 25 4 2020 32 W. MA 5/27/20 3235 Ocean View Blvd Corona Del Mar, CA 5/27/2020 1 of 37 KNA ENGINEERING, INC. A STRUCTURAL CONSULTING FIRM 30423 CANWOOD STREET -SUITE #223 o AGOURA HILLS, CA 91301 (818) 865-2026 LOAD CRITERIA FLAT ROOF DL CEILING DL ROOFING 3.0 PSF REROOFING 3.0 C.J. 3.0 PSF 5/8" PLYWOOD 1.8 INSULATION 2.0 RIPPING 1.7 CEILING 3.0 5/8" PLYWOOD 1.8 SPRINKLER 1.0 ROOF RAFTER 3.0 MISC. 1.0 INSULATION 2.0 CEILING 3.0 DL = 10.0 SPRINKLER 1.0 LL = 10.0 MISC. 1.7 DL = 22.0 PSF LL = 20.0 PSF EXTERIOR WALL DL 2x6 @ 16" O.C.STUCCO & 5/8" D.W 2x6@16"O.C. 1.7 PSF 7/8" STUCCO 10.0 5/8" D.W. 2.8 5 1/2" INSULATION 1.7 PL 1.0 MISC. 0.8 DL = 18.0 PSF INTERIOR WALL DL 2x6 @ 16" O.C. BOTH SIDES 5/8" D.W. 2x6 @ 16" O.C. 1.7 PSF 2-5/8" D.W. 5.6 5 1/2" INSULATION 1.7 PL 1.0 MISC. 1.0 DL = 11.0 PSF 3235 Ocean View Blvd �I �I Project: Job No: Corona Del Mar,CA KNA ENGINEERING, INC. — — _ Sheet:_ 5/27/2020 2 0f{37 STRUCTURAL CONSULTANTS Date: 30423 Canwood Street Suite 223 Agoura Mills, CA 91301 (818) 865-2026 dd�� KAN ENGINEERING, INC. Project Title: 3235 Ocean View Blvd 30423 Canwood Street Engineer: Corona Del Mar, CA Agoura Hills, CA 91301 Project ID: 5/27/2020 3 of 37 ph: (818) 865-2026 Project Descr: knaeng@pacbell.net Printed: 27 MAY.2020, 8:41AM �O®d Beim File: 14-016A Poo Bath :ec6 MM Software copyright ENERCALC, INC.1983-2020, Build:12.20.2.2I DESCRIPTION: TYP. R.R. CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: ASCE 7-16 Material Properties Analysis Method: Allowable Stress Design Fb + 900.0 psi E : Modulus of Elasticity Load Combination ASCE 7-16 Fb - 900.0 psi Ebend- xx 1,600.0 ksi Fc - Prll 1,350.0 psi Eminbend - xx 580.0 ksi Wood Species : Douglas Fir - Larch Fc - Perp 625.0 psi Wood Grade Nc.2 Fv 180.0 psi Ft 575.0psi Density 31.210pcf Beam Bracing : Beam is Fully Braced against lateral -torsional buckling Repetitive Member Stress Increase D(0.02926) Lr(0.0266) 2x10 Span = 12.0 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loads Uniform Load : D = 0.0220, Lr = 0.020 ksf, Tributary Width = 1.330 ft DESIGN SUMMARY B ;Maximum Bending Stress Ratio = 0.41a 1 Maximum Shear Stress Ratio = 0.149 : 1 Section used for this span 2x10 Section used for this span 2x10 = 594.43psi = 33.45 psi = 1,423.13psi = 225.00 psi Load Combination +D+Lr+H Load Combination +D+Lr+H Location of maximum on span = 6.000ft Location of maximum on span = 0,000ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.079 in Ratio = 1826>=360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.175 in Ratio = 825>=180 Max Upward Total Deflection 0.000 in Ratio = 0 <180 Overall Maximum Deflections Load Combination Span Max. "" Defl Location in Span Load Combination Max. "+" Defl Location in Span +D+Lr+H 1 0.1745 6,044 0.0000 0.000 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 0.353 0.353 Overall MINimum 0.160 0.160 +D+H 0.194 0.194 +D+L+H 0,194 0.194 +D+Lr+H 0.353 0.353 +D+S+H 0.194 0.194 +D+0,750Lr+0.750L+H 0.313 0.313 +D+0.750L+0.750S+H 0.194 0.194 +D+0.60W+H 0.194 0.194 +D+0.750Lr+0.750L+0.450W+H 0.313 0.313 KAN ENGINEERING, INC. Project Title: 3235 Ocean View Blvd 30423 Canwood Street Engineer: Corona bel Mar, CA Agoura Hills, CA 91301 Project ID: 5/27/2020 4 of 37 ph: (818) 865-2026 Project Descr: knaeng@pacbell.net Printed: 27 MAY 2020, 8:41AM Wood Beam Software cocvright ENERi DESCRIPTION: TYP. R.R. Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 +D+0.750L+0.750S+0.450W+H 0.194 0.194 +0.60D+0,60W+0.60H 0.116 0.116 +D+0.70E+0.60H 0.194 0.194 +D+0.750L+0.750S+0.5250E+H 0.194 0.194 +0.60D+0.70E+H 0.116 0.116 D Only 0.194 0.194 Lr Only 0.160 0.160 L Only S Only W Only E Only H Only KAN ENGINEERING, INC. Project Title: 3235 Ocean View Blvd 30423 Canwood Street Engineer: Corona Del Mar, CA Agoura Hills, CA 91301 Project ID: 5/27/2020 5 of 37 ph: (818) 865-2026 Project Descr: knaeng@pacbell.net Printed: 27 MAY 2020, 8:42AM Wood Beam) File: -016A Pool Bat .ec Software copyright ENERCALC, INC.1983-2020, Build:12.20.221 DESCRIPTION: HD-1 CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: ASCE 7-16 Material Properties Analysis Method: Allowable Stress Design Load Combination ASCE 7-16 Wood Species : Douglas Fir - Larch Wood Grade : No.2 Beam Bracing Completely Unbraced Fb + 900.0 psi Flo - 900.0 psi Fc - Prll 1,350.0 psi Fc - Perp 625.0 psi Fv 180.0 psi Ft 575.0 psi 4x6 Span = 6.0 ft E .' Modulus of Elasticity Ebend- xx 1,600.0 ksi Eminbend - xx 580.0 ksi Density 31.210pcf Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loads Uniform Load : D = 0.0220, Lr = 0.020 ksf, Tributary Width = 5.0 ft DESIGN SUMMARY Maximum Bending Stress Ratio = 0.451: 1 Maximum Shear Stress Ratio = 0.190 : 1 Section used for this span 4x6 Section used for this span 4x6 = 655.41 psi = 42.76 psi = 1,452.09psi = 225.00 psi Load Combination +D+Lr+H Load Combination +D+Lr+H Location of maximum on span = 3.000ft Location of maximum on span = 0.000ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.038 in Ratio = 1905>=360 Max Upward Transient Deflection 0.000. in Ratio = 0 <360 Max Downward Total Deflection 0.081 in Ratio = 889>=180 Max Upward Total Deflection 0.000 in Ratio = 0 <180 Overall Maximum Deflections Load Combination Span Max. "-': Defl Location in Span Load Combination Max. "+" Dell Location in Span +D+Lr+H 1 0.0809 3.022 0.0000 0.000 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 0.643 0.643 Overall MINimum 0.300 0.300 +D+H 0.343 0.343 +D+L+H 0.343 0.343 +D+Lr+H 0.643 0.643 +D+S+H 0.343 0.343 +D+0.750Lr+0.750L+H 0.568 0.568 +D+0.750L+0.750S+H 0.343 0.343 +D+0.60W+H 0.343 0.343 +D+0.750Lr+0.750L+0.450W+H 0.568 0.568 KAN ENGINEERING, INC. Project Title: 3235 Ocean View Blvd 30423 Canwood Street Engineer: Corona bel Mar, CA H Agoura Hills, CA 91301 Project ID: 5/27/2020 6 of 37 ph: (818) 865-2026 Project Descr: knaeng@pacbell.net Printed: 27 MAY 2020, 8:42AM UQt�@��1 File: _ - 1 A Pool Bath.ec6 Software copyright ENERCALC, INC.1983-2020, Bulld:12.20.2.2! DESCRIPTION: HD-1 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 +D+0.750L+0.750S+0.450W+H 0.343 0.343 +0.60D+0.60W+0.60H 0.206 0.206 +D+0.70E+0.60H 0.343 0.343 +D+0.750L+0.750S+0.5250E+H 0.343 0.343 +0.60D+0.70E+H 0.206 0.206 D Only 0.343 0.343 Lr Only 0.300 0.300 L Only S Only, W Only E Only H Only 3235 Ocean View Blvd GeoFirm Corona Del Mar, CA 5/27/2020 7 of 37 May 21, 2014 Project No: 71879-03 Report No: 14-7479 Page No: 4 elevation of 57 feet. The caisson row along the shoring wall is recommended to be embedded at least 35 feet below the proposed design lower floor elevation of 57 feet. In order to provide adequate slope stability factors of safety for the lower detached garage, and to provide adequate foundation support, an overexcavation and replacement with cement treated compacted fill soil is recommended for the lower garage building pad. 2013 CBC UPDATED RECOMMENDATIONS Recommendations presented in the referenced reports remain applicable to the current design, unless specifically superseded by the following. Seismic Structural Design Based oIN, �echnical_d�ta and site paramete—rs,�he f641Q ing is provided by the USGS (ASC `j D "'satisfy the 2013 CBC design criteria: Table 1, Site and Seismic Design Criteria Per ASCE 7-10 for 2013 CBC JQ Q Design Recommended `C/ Parameters Values Site Class B VV Site Longitude (degrees)-117.9273 i Site Latitude (degrees) 33.6227 U Ss (g) B 1.698 `J S 1 (g) B 0.627 SMs (g) D 1.698 V SM1 (g) D 0.627 SDs (g) D 1.132 SDI (g) D 0.418 �J Fa 1.0 Fv 1.0 Seismic Design Category D Slope Stability Caissons ------ Based on the current proposed construction, slope stability caissons are required to increase the static and pseudo -static factors of safety to current building code requirements. The locations of the stability caissons are shown on the attached Geotechnical Plot Plan, Figure 2. The top -of - slope row is recommended to consist of caissons that are embedded at least 40 feet below the U a o 0 0 0 0 4 0 0 4 0 0 0 0 4 0 0 4 0 0 q 0 W 0 W 0 n 0 10 0 In d n 0 0 t 0 W 0 N ui t0 n 0 n `-' N to 4 m o n 3 In O 5 n m N N W m m co co co co m 0 co co co <0 co t0 W O to N N LO LO LO N Ld Ld N Lo N to Lo (n Z II * it NCi U Q C) U C) CJ U U () U d (3 U RO) n n t0 p) in I, I, m in co to t0 f0 N a ® ® 0 ® ® ® J_ U U U U U U C) U U NI- O 0 0 0 0 0 0 00 Q�.V U d U U\U\\ \ U \ \ -U\ m d' In M d' N n n n An N.- QQN� @1 ® ® ® ® ® CU U FUQ O O N U 0 U U U U U U N U U U N U U U U 0 0 0 0 0 0\ � O O C5 O 0* 01 0 R o �-- A )n R W R - R t0 R n E 0 N A m L d� L I, n E U A n E •t' A N ® ® ® ® ® ® ® ® 3® 3® U N U N N fn U N U N U U N U N U N U U U U U U Q n N N N n N N N J I- U U C7 C7 C7 U U C.9 U U U U C9 C7 C9 U II II II R- II R w R ao ao ro ro L o0 R 00 0o ao R ao R ao L ao R ao L ao L ro R ro M M M M M M M M M H M M M M M M U C0U Uf U U d U U 00 O O O O O C3 O 0 0 0 C VOCU Um RO AO 0 p Nd ' Rp O N oo N N o0 Z® ® ® ® @ ® w w..w..w w..w..w..w W p W p W p W p W 0 W O W O W 0 O N m 9 0 N N 0 0� W W I=- W I=- W I=- W h W I=- W i=- W Z p O m Z O O m Z O O ro Z v O O mu Z p O m Z O �...i O m Z O O ro Z 0 O m yv Yv y yv y� m m m m m m m m m m m m m m m m ci ci ci ci ci ci ci ci ci ci ci ci c; ti ci ci 0 0 0 d 0 o ci 0 d A o C 0 A d L O E o E- 0 E d E t0 f0 t d' M n N N 0 c0 -0 t n n N N ® @ ® @J ® ® ® ® ® ® ® ® 0 0 0 0 0 0 0 0 v v v v v v m v o N W o J a J a J a J o_ J o_ J a J o_ J o_ J a J o_ J a J a J a J a J o_ J o_ FU U U U U U U U U U U U U U U U E N L N A N L N E N C N E N E N F N F N L N E N C N L N L N E N \ \ \ \ \ \ \ \ \ \ \ \ ) j Y. Q' Q m U o W U- U S Q m U a W 1.- U 2 - N 3235 Ocean View Blvd Corona Del Mar, CA 5/27/2020 8 of 37 J Z W Y Z LIJ 0 LL- N m LLI o W Z) N Q 0 J ~ Z cv J o Z W � WC W z IL U)\ 3 d O -1 W U O Z W li V O LLJ 0 (zn0 W J N Uz a)) ?� Z N (n 0 N J > LLI J m H Z= C� j Q (ri O F- fn 0 Wj U W I- O (j W 0 Z YW l' J o a vi Q LLgz °¢ om CD o W Z 0L'Z O J W—< J y 00 W N W > O w W O O W W O Qp �� a- 3�W W< UNW Z 0O W ¢'> W ~ O N J ~ o zo m, a 0 O "Co (,jL` JOQ a_ Z(n a_ zQ O MHO OZ =WSW OO 0 007 iz LJ U Q NFL H -0 (~n LOL \ U �W ZCn NQ\Op �7 Om C� Z J W z ¢J X F WO 0W O a_ M-0<3:U) OB (J N F 0W a_ O Z J Z- =�m Q O \a: W>O W paw Z_ W LLJO-J Ld LL �O LL JUNUO -Z��O ¢NIL000=nZ 00WrF- W mZQ oxQ �ZWI- QO Z\ WZ JLLI C)2 U O Z ,- N > J I- N > a- LLJ ¢ 2 M J� p W SLU > _ J ® -j ��oOJ zzJl-V)=jIL �oZF- Lj aoLm �w� �ooZ�� LLJ ?�o 0 o' OELUW0nm0 MF-0 XMmwM00 Nm ¢ LLI in U o LLJ N 1-N�J Z¢N mOJm�ZF-a_ZN(~n0 O 0- LL- 0 Zm = Q-J �(Zn W J WW Z d�¢ W W U\off ¢ om J O UQ mJ(n W to mW�j0 mQ LLJ H Q N O a ZUW J N m 0 U a 0= J Z U O W �' 0 ¢ W¢o=oJ�¢ ml-=O�zLLOo af ?cngJ aL`'cnOOOo>WomwOooZ� �- o(n(LEL 0JN000zoom(na: m:<L) 04 ZJ S W Wa_UJJ~J��JofJ 3 \F- =MONO ¢¢ J U (n ty a_ z J �- -j 04 J O J 00 W Z fn (n L� .- Z a_ Z a_ (n O ¢ Q Q Q Z 0 < 1n; ¢ L� Q 8 —.�— 2 2�� Z .- N n 'Lt' � O r �� 00 rn � O '7N Pr) d' to co I- iF ESR-2330 1 Most Widely Accepted and Trusted 323Pa9"r6Yjgw Blvd orona IYE-ar, CA TABLE 1B—ALLOWABLE TENSION LOADS AND DISPLACEMENTS FOR 5/27/2020 9 of 37 HDU SERIES HOLD-DOWN ASSEMBLIES''2,3.4 HOLD- MODEtL NO. SDS SIZE (iin ALLOWABLE TENSION LOADS', Pau(lbs) Co = 1.33 or Co = 1.6 AT DISPLACEMEN as (in.) MAXIMUM LOAD"' Wood Member Thickness' (in.) 3 3.5 4.5 5.5 7.25 5.5(7) Da,, As HDU2 '/4x1.5 1,810 1,810 1,810 1,810 1,810 1,810 0.069 0.090 '/gx2.5 3,075 3,075 3,075 3,075 3,075 3,075 0.088 0.118 HDU4 '/4xl.5 3,105 3,105 3,105 3,105 3,105 3,105 0.083 0,108 '/4x2.5 4,565 4,565 4,565 4,565 4,565 4,565 0.114 0.154 HDU5 '/4x1,5 3,960 3,960 3,960 3,960 3,960 3,960 0.109 0.142 '/4x2.5 5,645 5,670 5,670 5,670 5,670 5,670 0.115 0.158 HDU8 1/4x1.5 5,980 5,980 5,980 5,980 5,980 5,980 0.087 0.115 '/4x2.5 5,980 6,970 7,870 7,870 7,870 7,870 0.113 0.161 HDU11 1/4x2.5 — — — 9,535 11,175(" ) 11,175 0.137 0.182 HDU14 1/4x2.5 — — — — 14,390"0' 14,445 0.172 0.239 For SI: 1 inch = 25.4 mm, 1 Ibs = 4.45 N. 'Tabulated allowable loads are for a hold-down assembly consisting of the hold-down device attached to a wood structural member with the size of SIDS wood screws noted in the table. The quantity of SIDS wood screws must comply with Table 1A. 2The allowable loads for the hold-down assemblies are based on allowable stress design (ASD) and include the load duration factor, Co, corresponding with wind/earthquake loading in accordance with the NDS. No further increase is allowed. 'When using the basic load combinations in accordance with IBC Section 1605.31, the tabulated allowable loads for the hold-down assembly must not be increased for wind of earthquake loading. When using the alternative basic load combinations in IBC Section 1605.3.2 that include wind or earthquake loads that tabulated allowable loads for the hold-down assembly must not be increased by 331/3 percent, nor can the alternative basic load combinations be reduced by a factor of 0.75. 4Anchorage to concrete or masonry must be determined in accordance with Section 4.1.3 of this report. 'The tabulated allowable (ASD) tension loads must be multiplied by 1.4 to obtain the strength -level resistance loads associated with the tabulated Da deformations. 'The minimum thickness of the wood members (i.e., the dimension parallel to the long axis of the SIDS wood screws) must be as indicated in the table above. The minimum width of the wood members must be 31/2 inches, except as noted, 'The minimum width of the wood members must be 51/2 inches (6x6 nominal). 'Tabulated displacement values, Aau and As, for hold-down assemblies include all sources of hold-down assembly elongation, such as fastener slip, hold-down device extension and rotation, and anchor rod elongation, at ASD-level and strength -level forces, respectively. 9Elongation of the hold-down anchor rod must be calculated when the ASTM steel specification of the anchor rod differs from that described in the Section 3.2.4 of this report, or the actual unbraced length is greater than 6 inches. In lieu of calculating the elongation of the hold-down anchor rod for hold-downs raised 6 inches to 18 inches above the concrete, an additional 0.010 inch may be added to the tabulated hold-down displacement at allowable load, Dail, and an additional 0.014 inch may be.added to the tabulated hold-down displacement at strength -level load, As, to account for anchor rod elongation. "Requires a heavy hex anchor nut to achieve tabulated tension loads. TABLE 1C—ALLOWABLE TENSION LOADS AND DISPLACEMENTS OF HDU SERIES HOLD-DOWN CONNECTORS'2,3 x 0.75 2,300 3,400 4,200 5,200 7,100 10,800 HOLD-DOWN MODEL NO. ALLOWABLE TENSION LOAD, Pau (Ibs) DISPLACEMENT A AT MAX LOAD (in) oa11 As HDU2 3,505 0.081 0.110 HDU4 4,990 0.089 0.117 HDU5 5,670 0.078 0.107 HDU8 9,950 0.131 0.164 HDU11 11,905 0.121 0.157 HDU14 15,905"' 0.124 0.172 For SI: 1 inch = 25.4 mm, 1 Ibs = 4.45 N. 'This table lists the allowable tensile strength of the steel hold-down connectors exclusive of fasteners and anchor rods when tested on a steel 119. Allowable tension loads are applicable for designs complying with Section 12.11.2.2.2 of ASCE 7. 'When using the basic load combinations in accordance with IBC Section 1605.3.1, the tabulated allowable loads for the hold-down must not be Increased for wind of earthquake loading. When using the alternative basic load combinations in IBC Section 1605.3.2 that include wind or earthquake loads that tabulated allowable loads for the hold-down must not be increased by 331/3 percent, nor can the alternative basic load combinations be reduced by a factor of 0.75. 4Aa11 is the displacement at the tabulated ASD load and As is displacement at the strength -level load. Tabulated displacement values in Table .1 C consist only of deformation of the hold-down (tie -down) device when tested on a steel jig. Other variables contributing to total displacement, da, such as fastener slip, wood shrinkage, and anchor bolt/rod elongation, must be checked by the registered design professional. The tabulated allowable (ASD) tension loads must be multiplied by 1.4 to obtain the strength -level loads associated with the tabulated strength -level deformations, As. 'Requires a heavy hex anchor nut to achieve tabulated tension loads. 3235 Ocean View Blvd Corona Del Mar, CA 5/27/2020 10 of 37 ROOF DIAPHRAGM 3235 Ocean View Blvd Corona bel Mar, CA 5/27/2020 11 of 37 Seismic Analysis Based on IBC 12 / CBC 13 (Equivalent lateral -Force Procedure, ASCE 7-10 12.8) CS max.= SDI Ta=Ct(hn)075 1= 1.0 T(R/1) = 0.02x 11 0.75 R= 6.5 = 0.799 = 0.121 < 0.5 Z= 0.4 —> k = 1 hn= 11 Occupancy Category: 11 Ss= 1.698 Site class: D S1= 0.627 Seismic design category: D Fa= 1.00 Latitude: - Fv= 1.50 Longitude: - SMs= (Fa)(Ss)= 1.698 Redundancy Factor p : 1.3 SDs= 2/3(SMs)= 1.132 SM1= (Fv)(S1)= 0.941 SDI= 2/3(SM1)= 0.627 CS = SDs (R/1) = 0.174 CS MIN.= 0.01 CS MIN.= 0.5S1 (R/1) 0.0482 0.174 use Seismic Factor= 0.174 /1.4 = 0.124 WHEN S1< 0.6 WHEN S1> 0.6 Total Base Shear V = 8,988 X 0.124 = 1118 lb = 1 kips (ASD) x 1.3 = 1 kips ROOF DIAPHRAGM Area sq.ft 1 14.0 x 11.0 = 154 E 154 SQ.FT Trellis F = 10'x16'/2x5psfx0.124 = 50 lb Unit load psf lb x 7.26 = 1,118 3235 Ocean View Blvd Corona bel Mar, CA 5/27/2020 12 of 37 SEISMIC LOAD 3235 Ocean View Blvd Corona Del Mar, CA 5/27/2020 13 of 37 ROOF DL: 154 Sq,Ft x 22 psf = 3,388 EXT. WALL: 50 'x 5.0 'x 18 psf = 4,500 INT. WALL: 20'x 5.0'x 11 psf= 1,100 E 8,988 x 0.124 = 1,118 ROOF DL LEVEL H DL DLxH DLxH F Dist. Load Area Unit Load ROOF 11.0 1,118 12,299 1.000 1,118 154 7.26 E 1,118 E 12,299 3235 Ocean View Blvd Corona bel Mar, CA 5/27/2020 14 of 37 SHEAR WALLS FROM ROOF TO 2ND FLOOR LINE 1 AREA F = 0.50 x 1 F = 0.50 x 1118 F = 559 lb x 1.3 = 727 lb P L = 13.5 L = 13.5 ft V = 727 / 13.5 V = 54 If p (0.6-0.14SIDS) WALL HT WALL WT WALL HT ROOF WT ROOF SPAN �/ WALL LENGTH HD = 54 x 10 -( 18 x 10 + 22 x 1 )x 0.44 x 14 / 2 HD = -86 lb TYPE 1A NO HD Req'd LINE 2 AREA TRELLIS F = 0.50 x 1 + 1.00 x 50 F = 0.50 x 1118 + 1.00 x 50 F = 609 lb x 1.3 = 792 lb P L= 7 L = 7 ft V = 792 / 7 V = 113 plf WALL HT WALL WT WALL HT ROOF WT ROOF SPAN WALL LENGTH HD = 113 x 10 -( 18 x 10 + 22 x 1 )x 0.44 x 7 / 2 HD = 819 lb TYPE 1A HDU2 3235 Ocean View Blvd Corona bel Mar, CA 5/27/2020 15 of 37 SHEAR WALLS FROM ROOF TO 2ND FLOOR LINE A AREA TRELLIS F = 0.50 x 1 + 1.00 x 50 F = 0.50 x 1118 + 1.00 x 50 F = 609 lb x 1.69 = 1,029 lb 1.3pxl.3 Odhognal Effect L= 5 L= 5 ft V = 1029 / 5 V = 206 plf I (0.6-0.14Sos) WALL HT WALL WT WALL HT ROOF WT ROOF SPAN WALL LENGTH HD = 206 x 10 -( 18 x 10 + 22 x 5 )x 0.44 x 5 / 2 HD = 1,738 lb TYPE 1A HDU2 LINE B AREA TRELLIS F = 0.51 x 1 + 1.00 x 50 F = 0,51 x 1118 + 1.00 x 50 F = 620 lb x 1.3 = 806 lb P L= 4 L= 4ft H/W=10/4=2.5<3.450K V= 806 /4 2W/H = 2x4/ 10 = 0.80 1A Capacity = 280xO.80 = 224 PLF V = 202 plf WALL HT WALL WT WALL HT ROOF WT ROOF SPAN WALL LENGTH HD = 202 x 10 -( 18 x 10 + 22 x 5 )x 0.44 x 4 / 2 HD = 1,760 lb TYPE 1A HDU2 Rc: Tannir 3235 Ocean View ,Blvd Corona Del Mar, CA 5/27/2020 16 of 37 Subject: Re: Tannir From: Russ Lamb <rlamb@stoneymiller.com> Date: 6/19/2017 10:46 AM To: Armond Yeghiayan <armond@knaengineering.com> CC: Kamran Naraghi <kamran@knaengineering.com>, Martin Bard <MartinB@bja-inc.com> Use 90 pcf load at 4 foot high. This is temporary load so no seismic needed. 90 pcf accounts for impact load. Sent from my Wad �On Jun 19, 2017, at 10:05 AM, Armond Yeghiayan <armond_@knaengineeringcom> wrote: Q I �Vj vj Hi Russ, I j Please provide equivalent fluid pressure for debris wall at garage. Do I have to add se' is load or impact load to the wall? �l J� Regards, Armond Yeghiayan,P.E. Project Engineer armond@knaengLneeriog-.com KNA ENGINEERING, INC. 30423 Canwood Street, Suite 223 Agoura Hills, CA 91301 TEL: (818) 865-2026 FAX: (818) 865-1889 EMAIL: knaenp,@Pacbett.net KNA Engineering, Inc. is sending electronic files per your request. In accepting and utilizing any drawings, reports and data on_*Zray_� electronic media generated and furnished by Consultant (KNA ENGINEERING, INC), the Client or recipient on behalf of Client agrees that all such electronic files are instruments of service of the Consultant (KNA ENGINEERING, INC.), who shall be deemed the author and shall retain all common law, statutory law, and other rights including copyrights. The Client or recipient on the behalf of the Client agrees not to reuse these electronic files in whole or in part for any purpose other than for the Project. The Client or recipient agrees not to transfer these files to others without the consent of the Consultant (KNA ENGINEERING, INC.) If you have received this e-mail in error, please immediately notify the sender 1 of 2 6/19/2017 11:23 AM IA -�� \ (,0 ct an iev� A lvd �rlo� �9 Mar, , a 5727/2020 17 of 37 September 12, 2013 Project No: 71879-01 Report No: 13-7345r Page No: 14 slabs be underlain by a 15-mil thick vapor retarder/barrier (Stego Wrap or equivalent) placed over the gravel in accordance with the requirements of ASTM E: 1745 and E: 1643. Conventional spread footings embedded into competent bedrock or terrace deposits may be designed for an allowable bearing value of 4000 or 2500 pounds per square foot, respectively. Footings should be designed with a ' minimum width of 1.8 inches and a minimum embedment of 24 inches below the, lowest adjacent grade. Actual footing. depth and width should be governed by CBC requirements and the structural engineering design. The design value may be increased one-third for short duration wind or seismic loading. Settlement due to footing loads is anticipated to be nil in bedrock and 3/4-inch in terrace deposits. Lateral loads may be resisted by passive pressureforces and by.ffiction acting on the bottom of footings. The allowable passive pressure forces may be computed, using an equivalent -fluid density of 400 pounds per cubic -foot for bedrock and terrace deposits. A, coefficient of friction of 0.35 may be used in computing the frictional resistance. 2. Moisture Content of Slab Sub ado Soils Presoaking of slab subgrade soils is recommended prior to construction of slabs. We recommend that subgrade soils be soaked to at least 140 percent of optimum moisture content to a depth of 18-inches or more prior to placing gravel. 3. Caissons Caissons utilized for foundation support and shoring/retaining walls should be a minimum 24-inch diameter and embedded into competent bedrock a minimum depth of 10 feet. Caissons may be designed J.'or a dead plus live load end bearing value of 10,000 pounds per square foot for bedrock. These values may be increased by one-third for wind and seismic forces. A skin friction value of 400 pounds per square foot may also be used for bedrock. Settlement of caisson foundations in bedrock is anticipated to be less than 1/4-inch. Lateral resistance may be computed utilizing 400 pounds per square foot per foot of depth for competent bedrock or terrace deposits. The lateral resistance value provided above for bedrock may act on a tributary area of twice the caisson diameter. No lateral resistance may be taken in the beach deposits, slope wash or fill material. An allowable coefficient of -friction of 0.35 may be assumed for bedrock. 4. Slope Setback The base of all footings and caissons should be deepened as necessary to establish a horizontal distance of 15 feet as measured froze the bottom edge of the foundation to the slope face. 3235 Ocean View Blvd Corona Del Mar, CA GioFirm 5/27/2020 18 of 37 May 21, 2014 Project No: 71879-03 Report No: 14-7479 Page No: 5 proposed design lower floor elevation of 57 feet. The caisson row along the shoring wall is recommended to be embedded at least 35 feet below the proposed design lower floor elevation of 57 feet. The lateral resistance required for the top -of -slope row of caissons and shoring row of caissons is 25 and 8 kips per lineal foot, respectively, which should be applied uniformly over the upper 1.5 feet of the caisson. Caissons should be a minimum 24-inch diameter. Lateral resistance, bearing capacity and other design values were previously presented in the referenced reports. Actual caisson depth, size and spacing should be designed by the structural engineer. The caissons may also be used for structural support of the residence or other improvements. Overexcavation and Cement Treated Compacted Fill Based on the current proposed location of the lower detached garage, a 5-foot deep overexcavation and replacement with cement treated compacted fill is recommended in order to achieve adequate slope stability factors of safety, and to provide adequate foundation support for the structure. The overexcavation should extend 5 feet beyond the footprint of the structure, where practical. Soil cement compacted fill should consist of a mixture of the existing beach deposits soil material with a minimum of 2 percent cement. The fill should be moisture conditioned and compacted in accordance with the recommendations provided in the referenced reports. LIMITATIONS This investigation has been conducted in accordance with generally accepted practice in the engineering geologic and soils engineering field. No further warranty is offered or implied. Conclusions and recommendations presented are based on subsurface conditions encountered and are not meant to imply a control of nature. As site geotechnical conditions may alter with time, the recommendations presented herein are considered valid for a time period of one year from the report date. The recommendations are also specific to the current proposed development. Changes in proposed land use or development may require supplemental investigation or recommendations. Also, independent use of this report in any form cannot be approved unless specific written verification of the applicability of the recommendations is obtained from this firm. 3235 Ocean View Blvd Project Name/Number : stairs wall Corona 4I Mar CA KNA ENGINEERING, INC. Title Pool:Bath Slough Wall -age : T �t 37 30423 Canwood Street, #223 Dsgnr: AY7J2Ib1AYY2�f Agoura Hills, CA 91301 Description.... ph: (818) 865-2026 knaeng@pacbell.net This Wall in File: C:\KNA Calc\2014\14-016 Tannir\2020-05-26 Pool Bath\stairs wall.RPX RetainPro (c) 1987-2019, Build 11.20.03.31 License: KW-06058806 Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,AC1 530-13 License To: KNA ENGINEERING INC. Criteria I I Soil Data Retained Height = 3.50 ft Wall height above soil = 0.00 ft Slope Behind Wall = 0.00 Height of Soil over Toe = 9.00 in Water height over heel = 0.0 ft Surcharge Loads Surcharge Over Heel = 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 Used for Sliding & Overturning Axial Load Applied to Stem -11111 Axial Dead Load = 0.0 Ibs Axial Live Load = 0.0 Ibs Axial Load Eccentricity = 0.0 in Design Summary Wall Stability Ratios Overturning = 1.70 OK Sliding = 1.57 OK Total Bearing Load = 1,454 Ibs ...resultant ecc. = 7.61 in Allow Soil Bearing = 2,500.0 psf Equivalent Fluid Pressure Method Active Heel Pressure = 90.0 psf/ft Soil Pressure @ Toe = 1,001 psf OK Soil Pressure @ Heel = 0 psf OK Allowable = 2,500 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 1,402 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 4.8 psi OK Footing Shear @ Heel = 4.7 psi OK Allowable = 75.0 psi Sliding Calcs Lateral Sliding Force = 1,015.3lbs less 100% Passive Force = - 1,088.9 Ibs less 100% Friction Force = - 508.8 Ibs Added Force Req'd = 0.0 Ibs OK ....for 1.5 Stability = 0.0 Ibs OK Passive Pressure Soil Density, Heel Soil Density, Toe FootingllSoil Friction Soil height to ignore for passive pressure Lateral Load A Lateral Load ...Height to Top ...Height to Bottom Load Type Wind on Exposed (Service Level) = 400.0 psf/ft = 110.00 pcf = 110.00 pcf •t . -� = 0.350 = in ed o Stem Adjacent Footing Load 0.0 #/ft Adjacent Footing Load = 0.0 Ibs 0.00 ft Footing Width = 0.00 ft = 0.00 ft Eccentricity = 0.00 in = Wind (W) Wall to Ftg CL Dist = 0.00 ft (Service Level) Footing Type Line Load Base Above/Below Soil _ 0.0 ft = 0.0 psf at Back of Wall \ Poisson's Ratio = 0.300 Stem Construction Vertical component of active lateral soil pressure IS considered in the calculation of soil bearing pressures. Load Factors Building Code CBC 2016,AC1 Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.000 Seismic. E 1.000 Design Height Above Ftg Wall Material Above "Ht" Design Method Thickness Rebar Size Rebar Spacing Rebar Placed at Design Data fb/FB + fa/Fa Total Force @ Section Service Level Strength Level Moment.... Actual Service Level Strength Level Moment..... Allowable Shear..... Actual Service Level Strength Level Shear..... Allowable Anet (Masonry) Rebar Depth 'd' Masonry Data fm Fs Solid Grouting Modular Ratio 'n' Wall Weight Short Term Factor Equiv. Solid Thick. Masonry Block Type Masonry Design Method Concrete Data fc Fy Bottom Stem OK ft = 0.00 = Concrete LRFD 6.00 # 5 = 16.00 = Edge 0.251 Ibs = Ibs = 882.0 ft-# _ ft-#= 1,029.0 = 4,094.1 psi = psi = 17.6 psi = 75.0 in2 = in = 4.19 psi = psi = psf = 75.0 = Medium Weight = ASD psi = 2,500.0 psi = 60,000.0 3235 Ocean View Blvd Project Name/Number : stairs wall Corona D I Mar CA KNA ENGINEERING, INC. Title Pool Bath Slough Wall 5 2 &p9g f 37 30423 Canwood Street, #223 Dsgnr: AY f52ai MAY Agoura Hills, CA 91301 Description.... ph: (818) 866-2026 knaeng@pacbell.net This Wall in File: C:\KNA Calc\2014\14-016 Tannir\2020-05-26 Pool Bath\stairs wall.RPX RetainPro (c) 1987.2019, Build 11.20.03.31 License: KW-06068806 Cantilevered Retaining Wall Code: CBC 2016,AC1 318-14,AC1 530-13 License To: KNA ENGINEERING, INC. Concrete Stem Rebar Area Details Bottom Stem Vertical Reinforcing Horizontal Reinforcing As (based on applied moment) : 0.0591 in2/ft (4/3) " As : 0,0788 in2/ft Min Stem T&S Reinf Area 0.504 in2 200bd/fy : 200(12)(4.1875)/60000 : 0.1675 in2/ft Min Stem T&S Reinf Area per ft of stem Height: 0.144 in2/ft 0.0018bh : 0.0018(12)(6) : 0.1296 in2/ft Horizontal Reinforcing Options : One layer of : Two layers of: Required Area : 0.1296 in2/ft #4@ 16.67 in #4@ 33.33 in Provided Area : 0.2325 in2/ft #5@ 25.83 in #5@ 51.67 in Maximum Area: 0.5673 in2/ft #6@ 36.67 in #6@ 73.33 in Footing Data Footing Design Results Toe Width = 1.75 ft Toe Heel Heel Width = 1.25 Factored Pressure = 1,402 0 psf Total Footing Width = 3.00 Mu': Upward = 19,969 4 ft-# Footing Thickness = 15.00 in Mu': Downward = 5,954 378 ft-# Mu: Design = . 1,168 374 ft-# Key Width = 10.00 in Actual 1-Way Shear = 4.77 4.68 psi Key Depth = 4.00 in Allow 1-Way Shear = 75.00 40.00 psi Key Distance from Toe = 0.00 ft Toe Reinforcing = # 6 @ 16.00 in fc = 2,500 psi Fy 60,000 psi Heel Reinforcing = None Spec'd Footing Concrete Density = 150.00 pcf Key Reinforcing = # 5 @ 16.00 in Min. As % = 0.0018 Footing Torsion, Tu = 0.00 ft-Ibs Cover @ Top 2.00 @ Btm: 3.00 in Footing Allow. Torsion, phi Tu = 0.00 ft-Ibs If torsion exceeds allowable, provide supplemental design for footing torsion. Other Acceptable Sizes & Spacings Toe: #4@ 7.40 in, #5@ 11.48 in, #6@ 16.29 in, #7@ 22.22 in, #8@ 29.25 in, #9@ 37 Heel: phiMn = phi'5'lambda'sgrt(fe)'Sm Key: phiMn = phi'5'lambda'sgrt(fc)'Sm Min footing T&S reinf Area 0.97 in2 Min footing T&S reinf Area per foot 0.32 in2 A If one layer of horizontal bars: If two layers of horizontal bars: #4@ 7.41 in #4@ 14.81 in #5@ 11.48 in #5@ 22.96 in #6@ 16.30 in #6@ 32.59 in Project Name/Number : stairs wall KNA ENGINEERING, INC. Title Pool:Bath Slough Wall - 30423 Canwood Street, #223 Dsgnr: AY Agoura Hills, CA 91301 Description.... ph: (818) 865-2026 knaeng@pacbell.net This Wall in File: C:\KNA Calc\2014\14-016 Tannir\2020-05-26 Pool Bath\stairs waII.RPX License: KW-06068806 License To : KNA ENGINE Summary of Overt Item HL Act Pres (ab water tbl) HL Act Pres (be water tbl) Hydrostatic Force Buoyant Force = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load = Load @ Stem Above Soil = Cantilevered Retaining Wall n- & Resisting Forces & Moments .....OVERTURNING..... Force Distance Moment Ibs ft ft-# 1,015.3 1.58 Total = 1,016.3 O.T.M. = 1,607.6 Soil Over HL (ab. water tbl) Soil Over HL (bel. water tbl) Watre Table Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem = * Axial Live Load on Stem = Soil Over Toe = Surcharge Over Toe = Stem Weight(s) _ ^�, ^ Earth @ Stem Transitions= Resisting/Overturning Ratio = 1.70 Vertical Loads used for Soil Pressure = 1,453.9 Ibs Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. 3235 Ocean View Blvd Corona WAY ar CA P(t2®f 37 Code: CBC 2016,ACI 318-14,AC1 530-13 ...RESISTING..... Force Distance Moment Ibs ft ft-# 288.8 2.63 758.0 2.63 758.0 144.4 0.88 126.3 262.5 2.00 525.0 Footing Weighi = 562.5 1.50 843.8 Key Weight = 41.7 0.42 17.4 Vert. Component = 154.1 3.00 462.2 Total = 1,453.9 Ibs R.M.= 2,732.6 * Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Defl @ Top of Wall (approximate only) 0.032 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe because the wall would then tend to rotate into the retained soil. Project Name/Number : stairs wall KNA ENGINEERING, INC. Title Pool Bath Slough Wall 30423 Canwood Street, #223 Dsgnr: AY Agoura Hills, CA 91301 Description.... ph: (818) 865-2026 knaeng@pacbell.net This Wail in File: C:\KNA Calc\2014\14-016 Tannir\2020-05-26 Pool Bath\stairs wall.RPX 3235 Ocean View Blvd Corona D&�1 gMar CA 56it;!24�fdIAY??Af 37 Llcensef !SW-06068806. ...- Y_1.`.- .-_I_ Cantilevered Retaining Wall Code: CBC 2016,AC1 318-14,AC1 530-13 91 .6 Ti 5:I 3235 Ocean View Blvd Project Name/Number : stairs wall Corona D 1 Mar CA KNA ENGINEERING, INC. Title Pool:Bath Slough Wall p�g9e : 30423 Canwood Street, #223 Dsgnr: AY 5152at 2 MAY e6f 37 Agoura Hills, CA 91301 Description.... ph: (818) 865-2026 knaeng@pacbell.net This Wall in File: C:\KNA Calc\2014\14-016 Tannir\2020-05-26 Pool Bath\stairs Wall.RPX RetainPro (c) 1987-2019, Build 11.20.03.31 License: KW-06058806 Cantilevered Retaining Wall Code: CBC 2016,ACI 318-14,AC1 530-13 License To: KNA ENGINEERING, INC. .I,U a ,io Hydrostatic F'Dr e Lateral eaAl1 preature title to t:he oil BELOW water table 3235 Ocean View Blvd K N A ENGINEERING, INC. Project: _ _ job No:Corona Del Mar, CA —ml — —_ Sheet:_ 5/27/2020� 24 o ff37 _ STRUCTURAL CQNSUI..TANTS Client: ay:_.� Date: 30423 Canwood Street Suite 223 • Agoura Hills, CA 91301 (818) 865-2026 X //U Pl9/-''t d j (.« �1.,{r,"'s. t"a 2. 3235 Ocean View Blvd KNA ENGINEERING, INC.roject: _ __ job No: Corona bel Mar, CA �I1 Sheet: 572MC2 25 of 37 STRUCTURAL. CONSULTANTS Clier7t By: -- — Date: 30423 Canwood Street • Suite 223 Agoura Hills, CA 91301 • (818) 865-2026 ✓ - )) , t 1� L 3 4fv ..g a x, KAN ENGINEERING, INC. Project Title: 3235 Ocean View Blvd 30423 Canwood Street Engineer: Corona Del Mar, CA Agoura Hills, CA91301 Project ID: 5/27/2020 26 of 37 ph: (818) 865-2026 Project Descr: knaeng@pacbell.net Printed: 27 MAY 2020, 2:47PM I-WOOd Beam File: -0 6A Pool Bath.ec Software copyright ENERCALC, INC.1983-2020, 3u1Id.12.20.2.2t DESCRIPTION: T-1 CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: ASCE 7-16 Material Properties Analysis Method: Allowable Stress Design Fb + 900 psi E : Modulus of Elasticity Load Combination ASCE 7-16 Fb - 900 psi Ebend- xx 1600ksi Fc - Prll 1350 psi Eminbend - xx 580 ksi Wood Species : Douglas Fir - Larch Fc - Perp 625 psi Wood Grade : No.2 Fv 180 psi Ft 575 psi Density 31.21 pcf Beam Bracing : Beam is Fully Braced against lateral -torsional buckling D(0.045) Lr(0.045) 410 ` i Span =8.0ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loads Uniform Load : D = 0.0050, Lr = 0.0050 ksf, Tributary Width = 9.0 ft DESIGN SUMMARY 0 ;Maximum Bending Stress Ratio = 0.138.1 Maximum Shear Stress Ratio = 0.066 : 1 Section used for this span 4x10 Section used for this span 4x10 186.60psi = 14.57 psi 1,350.00psi = 225.00 psi Load Combination +D+Lr+H Load Combination +D+Lr+H Location of maximum on span = 4.000ft Location of maximum on span = 7.241 ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.011 in Ratio = 8499>=360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.024 in Ratio = 3942>=180 Max Upward Total Deflection 0.000 in Ratio = 0 <180 Overall Maximum Deflections Load Combination Span Max. "-" Dell Location in Span Load Combination Max. "+" Dell Location in Span +D+Lr+H 1 0.0243 4.029 0.0000 0.000 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 0.388 0.388 Overall MINimum 0.180 0.180 +D+H 0.208 0.208 +D+L+H 0.208 0.208 +D+Lr+H 0.388 0.388 +D+S+H 0.208 0.208 +D+0.750Lr+0.750L+H 0.343 0.343 +D+0.750L+0.750S+H 0.208 0.208 +D+0.60W+H 0.208 0.208 +D+0.750Lr+0.750L+0.450W+H 0.343 0.343 KAN ENGINEERING, INC. Project Title: 3235 Ocean View Blvd 30423 Canwood Street Engineer: Corona bel Mar, CA Agoura Hills, CA 91301 Project ID: 5/27/2020 27 of 37 ph: (818) 865-2026 Project Descr: knaeng@pacbell,net Printed: 27 MAY 2020, 2:47PM VdI00d C3e�CT1 File:. -0 6A Pool Bath:ec Software copyright ENERCALC, INC.1983-2020; 3u?, 12.20.2.2i DESCRIPTION: T-1 Vertical Reactions Support notation : Far left is #1 Values in KIPS . Load Combination Support 1 Support 2 +D+0.750L+0.750S+0.450W+H 0.208 0.208 +0,60D+0.60W+0.60H 0.125 0.125 +D+0.70E+0.60H 0.208 0.208 +D+0.750L+0750S+0.5250E+H 0.208 0.208 +0.60D+0.70E+H 0.125 0.125 D Only 0.208 0.208 Lr Only 0.180 0.180 L Only S Only W Only E Only H Only KAN ENGINEERING, INC. Project Title: 3235 Ocean View Blvd 30423 Canwood Street Engineer: Corona bel Mar, CA Agoura Hills, CA 91301 Project ID: 5/27/2020 28 of 37 ph: (818) 865-2026 Project Descr: knaeng@pacbell.net Printed: 27 MAY 2020, 2:49PM C10C� Beam.File:`14- Poo Bath:ec6 Software copyright ENERCALC, INC 1983-2020, Build:1220.2.2; DESCRIPTION: T-2 CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: ASCE 7-16 Material Properties Analysis Method : Allowable Stress Design Flo + 1350 psi E : Modulus of Elasticity Load Combination ASCE 7-16 Fb - 1350 psi Ebend- xx 1600 ksi Fc - Prll 925 psi Eminbend - xx 580 ksi Wood Species : Douglas Fir - Larch Fc - Perp 625 psi Wood Grade : No.1 Fv 170 psi Ft 675 psi Density 31.21 pcf Beam Bracing : Beam is Fully Braced against lateral -torsional buckling D(0.21) r(0.18) L; D(0.01) Lr(0.01) ' II 6x10 �. Span = 20.0 ft — --------- -------- Beam self weight calculated and added to loads Uniform Load : D = 0.0050, Lr = 0.0050 ksf, Tributary Width = 2.0 ft Point Load : D = 0.210, Lr = 0.180 k @ 14.0 ft DESIGN SUMMARY..._. ,Maximum Bending Stress Ratio = 0.2641 Section used for this span 6x10 = 428.59psi = 1,687.50psi Service loads entered. Load Factors will be applied for calculations. Maximum Shear Stress Ratio Section used for this span 614 ' ,F = 0.076 : 1 6x10 = 16.17 psi 212.50 psi Load Combination +D+Lr+H Load Combination +D+Lr+H Location of maximum on span = 13.723ft Location of maximum on span = 19.270ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.124 in Ratio = 1940>=360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.323 in Ratio = 742>=180 Max Upward Total Deflection 0.000 in Ratio = 0 <180 Overall Maximum deflections Load Combination Span Max. "-" Defl Location in Span Load Combination Max. "+" Defl Location in Span +D+Lr+H 1 0.3234 10.511 0.0000 0.000 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 0.430 0.586 Overall MINimum 0.154 0.226 +D+H 0.276 0.360 +D+L+H 0.276 0.360 +D+Lr+H 0.430 0.586 +D+S+H 0.276 0.360 +D+0.750Lr+0.750L+H 0.392 0.530 +D+0.750L+0.750S+H 0.276 0.360 +D+0.60W+H 0.276 0.360 KAN ENGINEERING, INC. Project Title: 3235 Ocean View Blvd 30423 Canwood Street Engineer: Corona bel Mar, CA Agoura Hills, CA 91301 Project ID: 5/27/2020 29 of 37 ph: (818) 865-2026 Project Descr: knaeng@pacbell.net Printed: 27 MAY 2020, 2:49PM Wood��� Fie: -016A Pool Bath.ec Software copyright ENERCALC, INC.1983-2020, Build:1220.22i DESCRIPTION: T-2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 +D+0,750Lr+0.750L+0.450W+H 0.392 0,530 +D+0.750L+0.750S+0.450W+H 0.276 0.360 +0.60D+0.60W+0.60H 0.166 0.216 +D+0.70E+0.60H 0.276 0,360 +D+0.750L+0.750S+0.5250E+H 0.276 0.360 +0.60D+0.70E+H 0.166 0.216 D Only 0.276 0.360 Lr Only 0.154 0.226 L Only S Only W Only E Only H Only KAN ENGINEERING, INC. Project Title: 3235 Ocean View Blvd 30423 Canwood Street Engineer: Corona Del Mar, CA Agoura Hills, CA 91301 Project ID: 5/27/2020 30 of 37 ph: (818) 865-2026 Project Descr: knaeng@pacbell,net Printed: 27 MAY 2020, 2:51 PM I-WdOii beam Fie: 14-016A Pool Bath.ec6 software copyright ENERCALC, INC.1983-2020, BuiId:12., 2t DESCRIPTION: T-3 CODE REFERENCES Calculations per NDS 2015, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set: ASCE 7-16 Material Properties Analysis Method: Allowable Stress Design Fb + 1,350.0 psi E : Modulus of Elasticity Load Combination ASCE 7-16 Fb - 1,350.0 psi Ebend- xx 1,600.Oksi Fc - Prll 925.0 psi Eminbend - xx 580.0 ksi Wood Species : Douglas Fir - Larch Fc - Perp 625.0 psi Wood Grade : No.1 Fv 170.0 psi Ft 675.0 psi Density 31.210 pcf Beam Bracing : Beam is Fully Braced against lateral -torsional buckling D(0�r(0.025) D(0.025) Lr(0.025) V z V a 6x10 } 6x10 Span = 6.0 ft Span = 8.0 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loads Load for Span Number 1 Uniform Load : D = 0.0050, Lr = 0.0050 ksf, Tributary Width = 5.0 ft Load for Span Number 2 Uniform Load : D = 0.0050, Lr = 0.0050 ksf, Tributary Width = 5.0 ft DESIGN SUMMARY Maximum Bending Stress Ratio = 0.096 1 Maximum Shear Stress Ratio = 0.046 :1 Section used for this span 6x10 Section used for this span 6x10 = 160.11 psi = 9.67 psi = 1,687.50psi = 212.50 psi Load Combination +D+Lr+H Load Combination +D+Lr+H Location of maximum on span = 6.000ft Location of maximum on span = 6.000ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.022 in Ratio = 6496>=360 Max Upward Transient Deflection -0.002 in Ratio = 54083>=360 Max Downward Total Deflection 0.054 in Ratio = 2648>=180 Max Upward Total Deflection -0.004 in Ratio = 22048>=180 Overall Maximum Deflections Load Combination Span Max. '2 Dell Location in Span Load Combination Max. "+" Dell Location in Span +D+Lr+H 1 0.0544 0.000 0.0000 0.000 2 0.0000 0.000 +D+Lr+H -0.0044 2.279 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Support 3 Overall MAXimum 0.751 0.107 Overall MINimum 0.306 0.044 +D+H 0.445 0.064 +D+L+H 0.445 0.064 +D+Lr+H 0.751 0.107 +D+S+H 0.445 0.064 KAN ENGINEERING, INC. Project Title: 3235 Ocean View Blvd 30423 Canwood Street Engineer: Corona Del Mar, CA Agoura Hills, CA 91301 Project ID: 5/27/2020 31 of 37 ph: (818) 865-2026 Project Descr: knaeng@pacbell.net Printed: 27 MAY 2020, 2:51 PM aOa beam File: 1 -016A Pool Bath.ec6 Soilware copyright ENERCALC, INC:1983.2020, BuiI'd 2.20.2.21 DESCRIPTION: T-3 Vertical Reactions Support notation: Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Support 3 +D+0.750Lr+0.750L+H 0.675 0.096 +D+0.750L+0.750S+H 0.445 0.064 +D+0.60W+H 0.445 0.064 +D+0.750Lr+0.750L+0.450W+H 0.675 0,096 +D+0.750L+0.750S+0.450W+H 0.445 0.064 +0.60D+0,60W+0.60H 0.267 0.038 +D+0.70E+0.60H 0,445 0.064 +D+0.750L+0.750S+0.5250E+H 0.445 0.064 +0.60D+0.70E+H 0.267 0.038 D Only 0.445 0.064 Lr Only 0,306 0.044 L Only S Only W Only E Only H Only 111111�!11 K N A ENGINEERING, INC. Project: N STRUCTURAL CONSULTANTS Client: 30423 Canwood Street - Suite223 - Agoura Hills, CA 91301 - (818)865-2026 I'li 0 5 j- I— J\' j -F L - A -� I—, Cc, � \K t— k,a ; 6 9 PW-7-- 3235 Ocean View Blvd Job No: Corona Del Mar, CA Sheet: 5/27/2020 32 # 37 By: Date: T , KAN ENGINEERING, INC. Project Title: 3235 Ocean View Blvd 30423 Canwood Street Engineer: Corona bel Mar, CA Agoura Hills, CA 91301 Project ID: 5/27/2020 33 of 37 ph: (818) 865-2026 Project Descr: knaeng@pacbell.net Printed: 27 MAY 2020, 2:18PM Steel Column .Software copyright ENERCP DESCRIPTION: TRELLIS COLUMN Code References Calculations per AISC 360-10, IBC 2015, CBC 2016, ASCE 7-10 Load Combinations Used: ASCE 7-16 General Information Steel Section Name : Pipe3STD Overall Column Height 10.0 ft Analysis Method : Load Resistance Factor Top & Bottom Fixity Top Free, Bottom Fixed Steel Stress Grade Brace condition for deflection (buckling) along columns Fy : Steel Yield 35.0 ksi X-X (width) axis: E: Elastic Bending Modulus 29,000.0 ksi Fully braced against buckling ABOUT Y-Y Axis Y-Y Sdepth) axis : Ful y braced against buckling ABOUT X-X Axis Applied Loads Service loads entered. Load Factors will be applied for calculations. Column self weight included : 75.80 Ibs * Dead Load Factor AXIAL LOADS ... Axial Load at 10.0 fit, D = 0.10 k BENDING LOADS ... Lat. Point Load at 10.0 ft creating Mx-x, E = 0.1060 k DESIGN SUMMARY Bending & Shear Check Results PASS Max. Axial+Bending Stress Ratio = Load Combination Location of max.above base At maximum location values are ... Pu 0.9 * Pn Mu-x 0.9 * Mn-x : Mu-y 0.9*Mn-y: PASS Maximum Shear Stress Ratio = Load Combination Location of max.above base At maximum location values are ... Vu : Applied Vn * Ph!: Allowable Load Combination Results Load Combination +1.40D+1.60H +1. 20 D+0. 50 L r+1. 6 0 L+1. 60 H +1.20 D+1.60 L+0.50S+1.60 H +1.20 D+1.6 0 L r+L+1.60 H +1.2 0 D+1.6 0 L r+0.5 0 W +1.6 0 H +1.20D+L+1.60S+1.60H +1.20 D+1. 60 S+0. 50 W +1. 60 H +1.20 D+0.50 L r+L+W+1.6 0 H +1.20 D+L+0. 50 S+W+1.60 H +0.90D+W+1.60H +1.20D+L+0.20S+E+1.60H +0.90D+E+0.90H Maximum Reactions Load Combination +D+H 0.1860 +1.20D+L+0.20S+E+1.60 H 0.0 ft 0.2110 k 65.205 k -1.060 k-ft 5.749 k-ft 0.0 k-ft 5.749 k-ft 0.006503 : 1 +1.20D+L+0.20S+E+1.60H 0.0 ft 0.1060 k 16.301 k Maximum Load Reactions . . Top along X-X Bottom along X-X Top along Y-Y Bottom along Y-Y Maximum Load Deflections .. . Along Y-Y 0.7350 in at for load combination :E Only Along X-X 0.0 in at for load combination : 0.0 k 0.0 k 0.0 k 0.1060 k 10.0ft above base 0.0ft above base Maximum Axial + Bending Stress Ratios Maximum Shear Ratios Stress Ratio Status Location Cbx Cby KxLx/Rx KyLy/Ry Stress Ratio Status Location 0.004 PASS 0.00 it 1.00 1.00 0.00 0.00 0.000 PASS 0.06ft 0.003 PASS 0.00 ft 1,00 1.00 0.00 0.00 0.000 PASS 0.00 ft 0.003 PASS 0.00 ft 1.00 1.00 0.00 0.00 0.000 PASS 0.00 ft 0.003 PASS 0.00 ft 1.00 1.00 0.00 0.00 0.000 PASS 0.00 ft 0.003 PASS 0.00 ft 1.00 1.00 0.00 0.00 0.000 PASS 0.00 ft 0.003 PASS 0.00 ft 1.00 1.00 0.00 0.00 0.000 PASS 0.00 ft 0.003 PASS 0.00 ft 1.00 1.00 0.00 0.00 0.000 PASS 0.00 ft 0.003 PASS 0.00 ft 1.00 1.00 0.00 0.00 0.000 PASS 0.00 ft 0.003 PASS 0.00 ft 1.00 1.00 0.00 0.00 0.000 PASS 0.00 ft 0.002 PASS 0.00 ft 1.00 1.00 0.00 0.00 0.000 PASS 0.00 ft 0.186 PASS 0.00 ft 1.00 1.00 0.00 0.00 0.007 PASS 0.00 ft 0,186 PASS 0.00 ft 1.00 1.00 0.00 0.00 0.007 PASS 0.00 ft Note: Only non -zero reactions are listed. Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction Mx - End Moments k-ft My - End Moments @ Base @ Base @ Top @ Base @ Top @ Base @ Top @ Base @ Top 0.176 KAN ENGINEERING, INC. Project Title: 3235 Ocean View Blvd 30423 Canwood Street Engineer: Corona bel Mar, CA Agoura Hills, CA 91301 Project ID: 5/27/2020 34 of 37 ph: (818) 865-2026 Project Descr: knaeng@pacbell.net Printed: 27 MAY 2020, 2:18PM t�@I Column 14-01 A Pool Bat .ec Software copyright ENERCALC, INC.1983-2020, BuiId:12.20.221 Software DESCRIPTION: TRELLIS COLUMN Maximum Reactions Note: Only non -zero reactions are listed. Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction Mx - End Moments k-ft My - End Moments Load Combination @ Base @ Base @ Top @ Base @ Top @ Base @ Top @ Base @ Top +D+L+H 0.176 +D+Lr+H 0.176 +D+S+H 0.176 +D+0.750Lr+0.750L+H 0.176 +D+0.750L+0.750S+H 0.176 +D+0.60W+H 0.176 +D+0.750Lr+0.750L+0.450W+H 0.176 +D+0.750L+0.750S+0.450W+H 0.176 +0.60D+0.60W+0.60H 0.105 +D+0.70E+0.60H 0.176 0.074 -0.742 +D+0.750L+0.750S+0.5250E+H 0.176 0.056 -0.557 +0.60D+0.70E+H 0.105 0.074 -0.742 D Only 0.176 Lr Only L Only S Only W Only E Only 0.106 -1.060 H Only Extreme Reactions Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction Mx - End Moments k-ft My - End Moments . Item Extreme Value @ Base @ Base @ Top @ Base @ Top @ Base @ Top @ Base @ Top Axial @ Base Maximum 0.176 " Minimum Reaction, X-XAxis Base Maximum 0.176 " Minimum 0.176 Reaction, Y-Y Axis Base Maximum 0.106 -1.060 1. Minimum 0.176 Reaction, X-XAxis Top Maximum 0,176 " Minimum 0.176 Reaction, Y-Y Axis Top Maximum 0.176 " Minimum 0.176 Moment, X-X Axis Base Maximum 0.176 " Minimum -1.060 0.106 -1.060 Moment, Y-Y Axis Base Maximum 0.176 " Minimum 0.176 Moment, X-X Axis Top Maximum 0.176 " Minimum 0.176 Moment, Y-Y Axis Top Maximum 0.176 " Minimum 0.176 Maximum Deflections for Load Combinations Load Combination Max. X-X Deflection Distance Max. Y-Y Deflection Distance +D+H 0.0000 in 0.000 ft 0.000 in 0.000 ft +D+L+H 0.0000 in 0.000 ft 0.000 in 0.000 ft +D+Lr+H 0.0000 in 0.000 ft 0.000 in 0.000 ft +D+S+H 0.0000 in 0.000 ft 0.000 in 0.000 ft +D+0.750Lr+0.750L+H 0.0000 in 0,000 ft 0.000 in 0.000 ft +D+0.750L+0.750S+H 0.0000 in 0.000 ft 0.000 in 0.000 ft +D+0.60W+H 0.0000 in 0.000 ft 0.000 in 0.000 ft +D+0.750Lr+0.750L+0.450W+H 0.0000 in 0.000 ft 0.000 in 0.000 ft +D+0.750L+0.750S+0.450W+H 0.0000 in 0.000 ft 0.000 in 0.000 ft +0.60D+0.60W+0.60H 0.0000 in 0.000 ft 0.000 in 0.000 ft +D+0.70E+0.60H 0.0000 in 0.000 ft 0.515 in 10.000 ft +D+0.750L+0.750S+0.5250E+H 0.0000 in 0.000 ft 0.386 in 10.000 ft +0.60D+0.70E+H 0.0000 in 0.000 ft 0.515 in 10.000 ft D Only 0.0000 in 0.000 ft 0.000 in 0.000 ft Lr Only 0.0000 in 0.000 ft 0.000 in 0.000 ft KAN ENGINEERING, INC. Project Title: 3235 Ocean View Blvd 30423 Canwood Street Engineer: Corona bel Mar, CA Agoura Hills, CA 91301 Project ID: 5/27/2020 35 of 37 ph: (818) 865-2026 Protect Descr: knaeng@pacbell.net Printed: 27 MAY 2020, 2:18PM Steel Column Filer14-016APoo Bath.ec6 Software copyright ENERCALC, INC.1983-2020, Build:12.20.2.2! DESCRIPTION: TRELLIS COLUMN Maximum Deflections for Load Combinations Load Combination Max. X-X Deflection Distance Max. Y-Y Deflection Distance L Only 0,0000 in 0.000 ft 0.000 in 0.000 ft S Only 0,0000 in 0,000 ft 0.000 in 0.000 ft W Only 0.0000 in 0,000 ft 0.000 in 0,000 ft E Only 0.0000 in 0.000 ft 0.735 in 10.000 ft H Only 0.0000 in 0.000. ft 0.000 in 0.000 ft Steel Section Properties : Pipe3STD Depth = 3.500 in I xx = 2.85 inA4 J = 5.690 1nA4 S xx = 1.63 inA3 Diameter = 3.500 in R xx = 1.170 in Wall Thick = 0.216 in Zx = 2.190 inA3 Area = 2.070 inA2 I yy = 2,850 inA4 Weight = 7.580 plf S yy = 1.630 inA3 R yy = 1.170 in Ycg = 0.000 in KAN ENGINEERING, INC. Project Title: 3235 Ocean View Blvd 30423 Canwood Street Engineer: Corona Del Mar, CA Agoura Hills, CA91301 Project ID: 5/27/2020 36 of 37 ph: (818) 865-2026 Project Descr: knaeng@pacbell.net Printed 27 MAY 2020. 2.3IPM General Footing oe a .e Software copyright ENERCALC, INC.19n2020, Buiid:12.20.2.21 DESCRIPTION: TRELLIS FOOTING Code References Calculations per ACI 318-14, IBC 2015, CBC 2016, ASCE 7-10 Load Combinations Used : ASCE 7-16 General Information Material Properties Soil Design Values fc : Concrete 28 day strength = 2.50 ksi Allowable Soil Bearing = 2.50 ksf fy: Rebar Yield = 60.0 ksi Increase Bearing By Footing Weight = No Ec : Concrete Elastic Modulus = 2,850.0 ksi Soil Passive Resistance (for Sliding) = 400.0 pcf Concrete Density = 145.0 pcf Soil/Concrete Friction Coeff. _ cp Values Flexure = 0.90 Shear = Analysis Settings 0.750 Increases based on footing Depth Min Steel % Bending Reinf. = Footing base depth below soil surface = Allow press. increase per foot of depth = 2.0 ft ksf Min Allow /o Temp Reinf. = 0.00180 when footing base is below = ft Min. Overturning Safety Factor = 1.0 : 1 Min. Sliding Safety Factor = 1.0 : 1 Increases based on footing plan dimension Add Ftg Wt for Soil Pressure No Allowable pressure increase per foot of depth Use ftg wt for stability, moments & shears Yes ksf Add Pedestal Wt for Soil Pressure No when max. length or width is greater than Use Pedestal wt for stability, mom & shear No ft Dimensions Width parallel to X-X Axis = 3.250 ft Length parallel to Z-Z Axis = 3.250 ft Z Footing Thickness = 16.0 in Pedestal dimensions... X = x px :parallel to X-X Axis = in pz : parallel to Z-Z Axis = in Height - in — -- Rebar Centerline to Edge of Concrete... i at Bottom of footing = 3.0 in Reinforcing Z 3'-3" Bars parallel to X-X Axis Number of Bars = 5.0 Reinforcing Bar Size = # 5 Bars parallel to Z-Z Axis Number of Bars = 4.0 Reinforcing Bar Size = # 5 Bandwidth Distribution Check (ACI 15.4.4.2) r Direction Requiring Closer Separation n/a a. + a.,.Al, cdda •.r.y R Fi ,r �7F 1 i r3 .,;+1_evS;e Y,7 # Bars required within zone n/a # Bars required on each side of zone n/a Applied Loads D Lr L S W E H P : Column Load = 0.30 k OB : Overburden = ksf M-xx = k-ft M-u = 1.10 k-ft V-x = 0.110 k V-z = k KAN ENGINEERING, INC. Project Title: 3235 Ocean View Blvd 30423 Canwood Street Engineer: Corona bel Mar, CA Agoura Hills, CA 91301 Project ID: 5/27/2020 37 of 37 ph: (818) 865-2026 Project Descr: knaeng@pacbell.net Printed: 27 MAY 2020, 2:31PM i1L'Pa' F00111 Gog Fi er -016A Pool Bath.ec6 software copyright ERCALC, ENINC.1983-2020, BuiId:1220.2,2i DESCRIPTION: TRELLIS FOOTING DESIGN SUMMARY ® Min. Ratio Item Applied Capacity _ Governing Load Combination PASS 0.1910 Soil Bearing 0.4774 ksf 2.50 ksf +0.60D+0.70E+H about Z-Z axis PASS n/a Overturning - X-X 0.0 k-ft 0.0 k-ft No Overturning PASS 4.643 Overturning - Z-Z 0.6545 k-ft 3.039 k-ft +0.60D+0.70E+H PASS 30.014 Sliding - X-X 0.0770 k 2.311 k +D+0.70E+0.60H PASS n/a Sliding - Z-Z 0,0 k 0.0 k No Sliding PASS n/a Uplift 0.0 k 0.0 k No Uplift PASS 0.01110 Z Flexure (+X) 0.2964 k-ft/ft 26.696 k-ft/ft +0.90D+E+0.90H PASS 0.004298 Z Flexure (-X) 0,1147 k-ft/ft 26.696 k-ft/ft +1.20D+L+0.20S+E+1.60H PASS 0.002436 X Flexure (+Z) 0.05250 k-ft/ft 21.549 k-ft/ft +1.40D+1.60H PASS 0.002436 X Flexure (-Z) 0.05250 k-ft/ft 21.549 k-ft/ft +1.40D+1.60H PASS 0.01713 1-way Shear(+X) 1,284 psi 75.0 psi +0.90D+E+0.90H PASS 0,004156 1-way Shear (-X) 0.3117 psi 75.0 psi. +1.20D+L+0.20S+E+1.60H PASS 0.001878 1-way Shear (+Z) 0.1408 psi 75.0 psi +1.40D+1.60H PASS 0.001878 1-way Shear (Z) 0.1408 psi 75.0 psi +1.40D+1.60H PASS 0,003707 2-way Punching 0.5561 psi 150.0 psi +1.20D+L+0.20S+E+1.60H Detailed Results Soil Bearing Rotation Axis & Load Combination... Gross Allowable Xecc Zecc (in) Actual Soil Bearing Stress @ Location Bottom, -Z Top, +Z Left, -X Right, +X Actual / Allow Ratio X-X, +D+H 2.60 n/a 0.0 0.1017 0.1017 n/a n/a 0.041 X-X, +D+L+H 2.50 n/a 0.0 0.1017 0.1017 n/a n/a 0.041 X-X, +D+Lr+H 2.50 n/a 0.0 0.1017 0,1017 n/a n/a 0.041 X-X, +D+S+H 2.50 n/a 0.0 0,1017 0.1017 n/a n/a 0.041 X-X, +D+0.750Lr+0.750L+H 2.50 n/a 0.0 0,1017 0,1017 n/a n/a 0.041 X-X, +D+0.750L+0.750S+H 2.50 n/a 0.0 0.1017 0.1017 n/a n/a 0.041 X-X, +D+0.60W+H 2.50 n/a 0.0 0.1017 0.1017 n/a n/a 0.041 X-X, +D+0.750Lr+0.750L+0.450W+H 2.50 n/a 0.0 0.1017 0,1017 n/a n/a 0.041 X-X, +D+0.750L+0.750S+0.450W+H 2.50 nla 0.0 0.1017 0,1017 n/a n/a 0.041 X-X, +0.60D+0.60W+0.60H 2.50 n/a 0.0 0.06104 0.06104 n/a n/a 0.024 X-X, +D+0.70E+0.60H 2.50 n/a 0.0 0.1017 0.1017 n/a n/a 0.041 X-X, +D+0.750L+0.750S+0.5250E+H 2.50 n/a 0.0 0.1017 0.1017 n/a n/a 0.041 X-X, +0.60D+0.70E+H 2.50 n/a 0.0 0.06104 0.06104 n/a n/a 0.024 Z-Z, +D+H 2.50 0.0 n/a n/a n/a 0.1017 0.1017 0.041 Z-Z, +D+L+H 2.50 0.0 n/a n/a n/a 0.1017 0.1017 0.041 Z-Z, +D+Lr+H 2.50 0.0 n/a n/a n/a 0,1017 0.1017 0.041 Z-Z, +D+S+H 2.50 0.0 n/a n/a n/a 0.1017 0,1017 0.041 Z-Z, +D+0.750Lr+0.750L+H 2.50 0.0 n/a n/a n/a 0.1017 0,1017 0.041 Z-Z, +D+0.750L+0.750S+H 2.50 0.0 n/a n/a n/a 0,1017 0.1017 0.041 Z-Z, +D+0.60W+H 2.50 0.0 n/a n/a n/a 0,1017 0.1017 0.041 Z-Z, +D+0,750Lr+0.750L+0.450W+H 2.50 0.0 n/a n/a n/a 0.1017 0.1017 0.041 Z-Z, +D+0.750L+0.750S+0.450W+H 2.50 0.0 n/a n/a n/a 0.1017 0,1017 0.041 Z-Z, +0.60D+0.60W+0.60H 2.50 0.0 n/a n/a n/a 0,06104 0,06104 0.024 Z-Z, +D+0.70E+0.60H 2.50 9.745 n/a nla n/a 0.0 0.2694 0.108 Z-Z, +D+0.750L+0.750S+0.5250E+H 2.50 7.309 n/a n/a n/a 0.0 0,2158 0.086 Z-Z, +0.60D+0.70E+H 2.50 16.242 n/a n/a n/a 0.0 0.4774 0.191 801 Glenneyre St. • Suite F • Laguna Beach • CA 92651 CITY OF NEWPORT BEACH CC!'`1LI-VTR E:EVELOPN,ENT DEPARTMU A iS TOTE v r APPROVAL OF THOSE PL J I TC CC rF' jT fr:1 H Trl ACH F L F�. (949) 494-2122 • FAX (949) 497-0270 GI ?-' E > AI LI'Ol �I, T THL_ t January 28, 2021 KAZ Investment Management c/o Brion Jeannette Architecture 470 Old Newport Boulevard Newport Beach, California 92663 Attention: Mr. Martin Bard - ;,. u T I\�q y�j ydiTH THE G � ulydAr: c5, +' aul-- oiv+itlj I -- J t\1El'-IT'_ (SIGNATVRE) SIGNATI r .. ProJect Nu:—�2334Il Repor-t No. - 2 _-8-9 �APPRO'JALTOIt DATE:_ Subject: Supplemental Geotechnical Recommendations for Slope Setback Behind the Proposed Pool Bath/Storage Building Residential Rear Yard Improvement 3235 Ocean Boulevard Corona Del Mar, California References: 1. Geofirm, 2013, "Update Preliminary Geotechnical Investigation, Proposed New Single -Family Residence, 3235 Ocean Boulevard, Corona del Mar, California", Project No. 71879-01, Report No. 13-7345r, dated September 12. 2. Geofirm, 2020, "Response to City of Newport Beach Grading/Drainage Plan Review Comments, 1 St Review and Building Plan Review Comments, dated July 20, 2020, Residential Rear Yard Improvement, 3235 Ocean Boulevard, Corona del Mar, California", Project No. 72370-10, Report No. 20-8764, dated September 2. Dear Mr. Bard: In accordance with the request of the City reviewer, this presents supplemental geotechnical recommendations for the design of the proposed rear yard improvements at the subject site. As indicated in our Report 20-8764, a caisson -supported debris wall system is recommended behind the proposed pool bath/storage building to provide adequate stability, a debris catchment area and adequate protection from slope drainage, erosion and shallow failures impacting the proposed structure. With regard to CBC slope setback requirements, Section 1808.7.5 allows the Building Official to approve "Alternative Setbacks and Clearances" provided such are based on a geotechnical investigation performed in accordance with Section 1803.5.10. The referenced report (Reference 1) has been performed in accordance with said Section. Potential debris volume was calculated, and debris catchment of 50 percent is achieved in our calculations provided in Figure 1, which is considered geotechnically acceptable and suitable for the intended use. Therefore, we recommend a 6-foot-hiah debris wall at the toe of the slope with a lateral impact loading of 125 pounds per cubic foot equivalent fluid pressure. On -going maintenance (i.e., periodic removal of debris from behind the wall, if any) should be anticipated. January 28, 2021 Project No: 72370-01 Report No: 21-8831 Page No: 2 Please note, the recommended debris wall system only applies to the proposed pool bath/storage building, and is not considered necessary for the proposed hardscape/landscape improvements. Thank you for this opportunity to be of service. If you have any questions, please contact this office. Respectfully submitted, Zi Wang, R.C.E Senior Engineer, R Date Signed: 1 / 28 / KAT/ZW:lt Attachments: Figure 1 — Pool Bath Debris Wall Calculation Distribution: Addressee Via Email No. iiCE 8099 M � 99 0 _o - 0 0 o U) E 0 0 o v - (D ¢ u Ln ) c � _ � m O -r �' c c O L C u N - N o o u _ o M -C c � N N i U O c C� Q)2 m 7 U) N IN U m O U o a N = u z _o O in u m O 0 Ln O a- m - N C) (Y 1 _ O - N O - N _ co v p r%j 00 - N -o - C O NN - _ 4 v 4 O ¢ m 3 O O O = L d - in a ��— C 1m O T f— r—i-1 80 1 Glenneyre St. • Suite F • Laguna Beach • CA 92651 (949) 494-2122 • FAX (949) 497-0270 November 17, 2020 6t1 1NQ OMSION KAZ Investment Management DEC, 7)0 c/o Brion Jeannette Architecture 470 Old Newport Boulevard W M-K Newport Beach, California 92663 Attention: Mr. Martin Bard Project No: 72370-10 Report No: 20-8813 Subject: Response to City of Newport Beach Grading/Drainage Plan Review Comments and Geotechnical Report Review Checklist, 2"d Review, dated October 13, 2020 and Building Plan Review Comments, dated October 7, 2020 Residential Rear Yard Improvement 3235 Ocean Boulevard Corona Del Mar, California Plan Check No. 1249-2020 This letter is in response to the City of Newport Beach, Planning Department, Grading/Drainage Plan Check Corrections and geotechnical report review checklist, dated October 7, 2020 and October 13, 2020. This review requested additional information on eight comments. A copy of the review sheets is provided in Appendix B. Our response is presented following each comment. Building Department Plan Review Comments: Item 10: Soil engineer to review and approve final foundation plan, foundation details, shoring plan, pool plan, precise grading and drainage plan and erosion plan. This correction will remain until the permit is issued. Response: Acknowledged. Item 19: Seismic parameters include in the Geofirm Response to City Comments, dated 912120 are not consistent with the requirements ofASCE 7-16 or the structural calculations. Site Class F requires site specific response analysis. Values provided are consistent with Site Class D (default) however values for SMr and SDI should be null per ASCE 7, section 11.4.8. Note that seismic design is required of all structures in Seismic Design Category D regardless of Rick Category. Response: Although the soils underlying the site are liquefiable and defined as site class F per the 2019 CBC, requiring a site -response analysis, proposed new structures are November 17, 2020 Project No: 72370-10 Report No: 20-8813 Page No: 2 anticipated to have fundamental periods of vibration less than 0.5 seconds (to be verified by the structural engineer). As such, Section 20.3.1 in ASCE 7-16 provides an exception that indicates such liquefiable sites may be classified in accordance with Tables 11.44-1 and 11.4-2 without performing a site -specific evaluation. Given the exception and the results of our onsite and nearby field investigations, which indicate the site is predominantly underlain by beach deposits and Monterey Formation bedrock with average N-values between 15 and 50, seismic design criteria may be calculated using a site classification of D. However, the Site Class remains F. As indicated in Section 21.3 of ASCE 7-16, for Site Class D: F is determined using Table 11.4-1, and F, is taken as 2.4 for Si < 0.2 or 2.5 for S1 > 0.2. Therefore, Fv as 2.5 was utilized to calculate seismic design criteria (SMi and SDi) provided in our referenced report. Grading/Drainage Plan Review Comments: Item 8: For projects on a slope, adjacent to a slope, with a basement, or project sites which require remedial grading, soils engineer to review and approve the grading plan, foundation plan, and shoring plan (if applicable) to verify that the design is consistent with the geotechnical report recommendations. Soils engineer to stamp these plans with a review stamp asserting compliance with geotechnical report recommendations. This comment will remain up to and include at the time of permit issuance. Response: Acknowledged. Item 20: Soil report shall address the potential of soft or compressible or collapsible or liquefiable soils (Site Classes E and F), and recommend mitigation method if they exist. Response: The site is underlain at depth by bedrock strata of the Monterey Formation, which are overlain by 10± feet of beach deposits. The beach deposits underlying the site are considered liquefiable, and therefore our office has performed an analysis for liquefaction potential based on the estimated standard penetration value N = 8 blows per foot (NAVFAC 7.1-14, Figure 1). Our analysis presented in Appendix D indicates liquefaction settlement within the Lipper 10 feet is estimated to be 2.5 inches approximately. A stiffened foundation or mat slab designed in accordance with the City's "Shallow Mitigation Methods" is recommended as below. The allowable bearing capacity for a mat slab placed on cement -treated fill with a thickness of 12 inches or more is 3,000 pounds per square foot. Foundation settlement from structural loading is estimated to be 3/a inch total and 1/2 inch differential over a distance of 20 feet. Foundation settlement should occur mostly during construction. November 17, 2020 Project No: 72370-10 Report No: 20-8813 Page No: 3 Lateral loads may be resisted by passive pressure forces and friction acting on the bottom of foundations. Passive pressure may be computed from an equivalent fluid density of 200 pounds per cubic foot, not to exceed 2,000 pounds per square foot. A coefficient of friction of 0.35 may be used in computing the frictional resistance. These values may be combined without reduction. Item 21: Soil report shall present seismic site coefficients with supporting documentation. Response: Seismic site coefficients were provided in the previous response report dated September 2, 2020. Please also refer to the response to Item 19 above. Geotechnical Report Review Checklist: Item 1: Please respond to Plan Check review AREV20-1088 and building review checklist. Response: Acknowledged. Item 2: Please provide caisson pool foundation parameters for structural engineering foundation design. Response: Caisson foundation recommendations for the proposed pool were provided in our supplemental letter dated June 19, 2020, as attached in Appendix C. Item 3: Please review the Grading, Foundation and Landscape Plans for compliance with Geotechnical recommendations of this report. Response: Acknowledged. November 17, 2020 Project No: 72370-10 Report No: 20-8813 Page No: 4 This opportunity to be of service is appreciated. If you have any questions, please call. Respectfully submitted, GEOFIRM ___C�91 10 KEVIN A, TRIGG Q NO. R00 0199 NO.1619 ff u� !, r T CERTIFIED I* C P.O�l 0l fl Kevin A. Trig�P_�G. ' ENGINEERING Zl Warig, R.C.E. 8019` i "`col ist �' �gq(}-OGIST /�� Senior Engineer Chief Enginecii Zg U g / g �, Iv►t, TFor cpo� oQ- Date Signed: 11/17/2020 CAS KAT/ZW:hsm Distribution: Email Attachments Appendix A - References Appendix B - City of Newport Beach Plan Review Comments, dated October 7, 2020 and October 13, 2020 Appendix C - Geofirm, 2020, "Supplemental Geotechnical Recommendations for Proposed Pool, 3235 Ocean Boulevard, Corona Del Mar, California", Project No. 72370-01, Report No. 20-8705R, revised June 19. Appendix D - Liquefaction Analysis El APPENDIX A REFERENCES APPENDIX A REFERENCES 1. Geofirm, 2014, "Update Geotechnical Recommendations for Project Design Revisions, Proposed New Single -Family Residence, 3235 Ocean Boulevard, Corona del Mar, California", Project No. 71879-03, Report No. 14-7479, dated May 21. 2. Geofirm, 2017, "Response to City of Newport Beach Geotechnical Report Review Checklist dated December 28, 2016, New Single -Family Residence, 3235 Ocean Boulevard, Corona Del Mar, California", Project No. 71879-05, Report No. 17-8002, dated January 18. 3. Geofirm, 2017, "Response to City of Newport Beach Geotechnical Report Review Checklist, Second Review dated February 16, 2017, New Single -Family Residence, 3235 Ocean Boulevard, Corona Del Mar, California", Project No. 71879-05, Report No. 17- 8034, dated June 27. 4. Geofirm, 2020, "Supplemental Geotechnical Recommendations for Proposed Pool, 3235 Ocean Boulevard, Corona Del' Mar, California", Project No. 72370-01, Report No. 20- 8705R, dated June 19. 5. Geofirm, 2020, "Response to City of Newport Beach Grading/Drainage Plan Review Comments, 1 St Review and Building Plan Review Comments, dated July 20, 2020, Residential Rear Yard Improvement, 3235 Ocean Boulevard, Corona Del Mar, California", Project No. 72370-10, Report No. 20-8764, dated September 2. APPENDIX B CITY OF NEWPORT BEACH PLAN REVIEW COMMENTS, DATED OCTOBER 7, 2020 AND OCTOBER 13, 2020 CITY OF NEWPORT BEACH COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 100 Civic Center Drive I P.O. Box 1768 1 Newport Beach, CA 92658-8915 www.newportbeachca.gov 1 (949) 644-3200 GRADING/DRAINAGE PLAN REVIEW COMMENTS Project Description: SFR REAR YARD SPA 46 SF, TRELLIS 347 SF, PATIO 996 SF AND ADDITION OF POOL BATH/STORAGE ROOM 154 SF Project Address: 3235 OCEAN BLVD NB Permit App. Date: 7/13/2020 CY Cut/Fill: 2050/308 Permit Valuation: $61,119 Architect/Engineer: DZNE,INC.. Applicant/Contact: JEANNETTE BRION S Plan Check Engineer: Sergio Gutierrez Plan Check No.: 1249-2020 Permit App. Expires: 1/9/2021 Adjusted Valuation: $ Phone: 949-3058920 Phone: 949-645-5854 Phone: 949-644-3213 Engineer email: sgutierrez newportbeachca.gov X 1 st Review: 7/2.0/2020 x 2nd Review: 1011312020 310 Review: Italic comments By Appointment The project plans were reviewed for compliance with the following codes and standards: 2019 CRC; 2019 CBC; 2019 CPC; 2019 CEC; 2019 CMC; 2019 California Energy Code; 2019 California Green Building Standards Code (CG); & Chapter 15 of the Newport Beach Municipal Code (NBMC) The code section references are from the 2019 CBC, unless otherwise stated. • TO EXPEDITE PROJECT APPROVAL: Please provide a written response indicating how and where each comment was resolved on the plans. • Resubmit all previously reviewed plans, updated plans and supporting documents with each subsequent review. • AFTER 2nd PLAN REVIEW. Please call the plan check engineer listed above to schedule a plan review appointment, to expedite project approval. • For clarification of any plan review comment, please call the plan check engineer listed above. • Plan review status is available online at www.newDortbeachcd.gov. Project status is also available using the interactive voice response system at 949-644-3266, or by speaking with a permit technician at 949-718-1888 during business hours. Correction Llsts\Grading/Drain agePlanRevComment 10/13/20 1 GENERAL 1. All permits related to the proposed project shall be issued at the same time, or separate plans and plan review will be required for items not issued with this review. Provide additional permit worksheets for the following: a. Accessory structures, detached patio covers and trellises, b. Detached or free-standing trash enclosures, C. Masonry or concrete fences over 3.5 ft high, d. Retaining walls over 4 ft high from the bottom of the foundation to the top of the wall. Obtain plan review approval from the following: a. Planning Department, b. Public Works Department, 3. Final drawings which will be approved for permit issuance shall be signed by the respective design professionals (electronic signature is acceptable). This comment will remain up to and include at the time of permit issuance. SURVEY CORRECTIONS: rRMENUM.- GRADING CORRECTIONS: Please Refer to PC # REV20-1088 for Grading/Drainage redlines prior to approval of this PC# 1249-2020 7. Two stamped and signed sets of plans are required for permit issuance (electronic signature is acceptable). This comment will remain up to and include at the time of permit issuance. 8. For projects on a slope, adjacent to a slope, with a basement, or project sites which require remedial grading, soils engineer to review and approve the grading plan, foundation plan, and shoring plan (if applicable) to verify that the design is consistent with the geotechnical report recommendations. Soils engineer to stamp these plans with a review stamp asserting compliance with geotechnical report recommendations. This comment will remain up to and include at the time of permit issuance. - -NOW- - - Correction Lists\Grading/Drain age Plan RevComment 10/13/20 fli. Provide a drainage design that prevents entFaRGe of drainage water frem the street/alley Onte 12 is And the di6taRG8 #GM property lines to adjaGeRt cfn Usti free v'cravaur�.r. drainage to ensure water d-A-es nAt drA*n Avpr thi- t p edge 9f aRy 619peS. 14. Show locations and details of subdrain system(s) and outlet for retaining walls on grading plan when subdrain is required by soils report. Subdrain to be piped separately from site drainage or invert in French drain to be higher than the invert elevation of the nearest drain. 15. Provide erosion and siltation control plans. 16. Provide a section showing required grading cut and proximity to property line. 17. Provide building or structure setbacks from top and bottom of slope as shown in CBC, Fig. 1808.7.1. For descending slopes less than 12 feet in height, minimum setback from competent slope face material shall be 4 feet. 1$ Top nnrl fee of clone to be sett@sly from the property lire per NBMS 15.19.1 Fog. 1- Y 1raa eve yr slope cv be aecvao�c ��v --P property -P , i9. Provide nin GGPIGS ef soils and fGundatie investigation rrepnrf by a reni64ered niVil engineer. 20. Soils report shall address the potential of soft or compressible or collapsible or liquefiable soils (Site Classes E and F), and recommend mitigation method if they exist. 21. Soils report shall present seismic site coefficients with supporting documentation. 22. List soils report recommendations on grading plan. WATER QUALITY CORRECTIONS: ■ ADDITIONAL CORRECTIONS: 24. See drawings for additional corrections. Please see PCREV20-1088 Grading sheet redlines to be revised. Correction Lists\Grading/Drain agePlanRevComment 10/13/20 Wn®� CITY OF NEWPORT BEACH COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION < 100 Civic Center Drive I P.O. Box 1768 1 Newport Beach, CA 92658-8915 rrrai��'` www.newportbeachca.gov 1 (949) 644-3200 PLAN REVIEW COMMENTS Project Description: SFR — New pool house and retaining wall Project Address: Permit App. Date Plan Reviewer: 3235 Ocean Blvd Plan Check No.: 1249-2020 7113/20 / 10/7/20 Valuation: $61,119 Melissa Kubischta, SE Phone: 949-644-3278 The project plans were reviewed for compliance with the following codes and standards: 2019 CRC; 2019 CBC; 2019 CPC; 2019 CEC; 2019 CMC; 2019 California Energy Code; 2019 California Green Building Standards Code (CG); & Chapter 15 of the Newport Beach Municipal Code (NBMC). Obtain plan review approval from the following: a. Building Division b. Grading C. Planning Division d. Public Works 1017120: Reminder,; 2. Final drawings which will be approved for permit issuance, shall be signed by the respective design professional (electronic signature is acceptable). This correction will remain until the permit is issued. 1017/20: Reminder. 3. Projects located within a "High Density Area" require the following form, htt s://www.newoortbeachca.aov/Home/ShowDocument?id=64600 reproduced on the title page of the plans with the owner's and contractor's signatures. 1017,120: Form not found on A-1 as indicated in response letter. 4. Update project scope of work to reflect new work not previously permitted that is shown on the plans. Provide complete construction information for spa or remove from scope of work. Include unconditioned pool bath/storage building. and trellis in the scope of work. All other grading and drainage must be shown on the drawings for the. open permit for the house and grading (plan check 2358-2014). 1017120: Provide note on the plan that the spa is under separate plan review and permit. Note that a portion of the sloughwall design is shown on the structural drawings on this set and must be included in the scope of work. Additionally, grading and erosion control for the pool bath and storage building is not shown on plan check 2358-2014 as indicated in the Scope of Work note on sheet A- l. Coordinate ;between this; plan and REV20-1088 so that all work including grading; "soil improvement, retaining/slough wall construction, drainage, bio-retention planter walls and raised wood deck at upper platform, and new building/trellis construction is shown somewhere and cross referenced between the drawings.. :r_*s��:�:r_tnr���:tisr:resr��:r_�:�n:a:r.� Floor plan for the new building should show electrical/mechanical components including required receptacles and exhaust fan for bath. 1017120: See red marked plan sheetA-1, provide legend for all electrical/mechanical symbols used on the plan. 7. Add note to plans to indicate all grading and drainage per plan check 2358-2014. 1017120: See correction item 4 for additional clarification. Grading information including updated Geotechnical recommendations for the new construction in the rear yard along Breakers Drive is not shown on plan check 2358-2014 or REV20-1088. 8. Note that this plan check will not be approved until REV20-1088 to plan check 2358-2014 is approved. 1017120: Reminder,. Note that Sheets G-1, G-2.1 and L-1 have been removed from this set and incorporated into REV20-1088 for plan check 2358-2014. Note that this permit will not be approved until the approved drawings for the open permit under plan check 2358-2014 are revised to reflect the updated site plan, landscape plan, and grading/drainage requirements including the new pool bath/storage building and trellis. 1017120: See correction items 4 and 7`for additional clarification. 10. Soils engineer to review and approve final foundation plan, foundation details, shoring plan, pool plan, precise grading and drainage plan and erosion plan. This correction will'remain until the permit is issued. 1017120: Reminder, a Sprinklers shall be installed to preteGt all areas ef a dwel!'Rg unit inGlud'Rg bathFGE)Fns mere than 56 square foot inarea. (R313.3.1.2) Submittals"prieF te issuing a buffildiRg permit, er, list URdeF 'Deferred en Gover sheet. PFevode a nete Gn the drawing stating� "ObtaiR fire sprinkler permit PFiGF te Galling for Fee sheathing incnontinn G Revise building data OR GGVeF sheet te ideRtify that building is equipped with a fiFe GpFinkleF 12. Handrails shall satisfy the following: a. Provide a minimum of one continuous handrail on stairways with 4 or more risers and at all open sides. R3117.8 b. Handrail height shall be 34" to 38" above the nosing of treads. R311.7.8.1 C. Handrail with circular cross -sections shall have a diameter of 1 W to 2". R311.7.8.5 item 1. d. Handrails with other than circular cross -sections shall have a perimeter of 4" to 6%" with a maximum cross=section dimension of 2%", R311.7.8.5 item 1 e, Handrails with a perimeter greater than 6%" shall comply with R311.7.8.5 item 2. f. Handrail shall be continuous without interruption by newel post or other obstruction, except at the landing, volute, or turnout on lowest tread. R311.7.8.4, Exception 1 & 2. g. Clear space between handrail and wall shall be 1W minimum. R311.7.8.3 1017,120: Detail handrail configuration and anchorage on plan. i 3. Previde reefing SP8GifiGatiens (ESR Report E)F Gther apprGved listing), inGluding rGef assembly fire etassifTsati9R, en the piers. ReeTeo`oeraR 14. Where drains and overflow are required, provide detail showing overflow piped separately and 2" higher than roof drain. R903.4.1 1017120: Show how roof drain down spout ties into the site stormwater drainage plan. 15. Geotechnical report does not provide any recommendations for construction of habitable buildings in the beach deposits and slopewash at the toe of the slope. Additionally, recommendations for the garage building slab included 5-feet of overexcavation with soil -cement treated fill. Provide updated geotechnical recommendations for pool bath/storage building at toe of slope and specify all required overexcavation and soil strengthening requirements per the geotechnical report on the plans. Provide grading cut showing overexcavation for the new building with respect to the existing slope. 1017120 Coordinate between the structural design, plans, and Geofirm Response to City Comments, dated 912120., 2 16. Buildings below slopes shall be set a sufficient distance from the slope to provide protection from slope drainage, erosion and shallow failures. Provide sufficient clearance from toe of slope per CBC 1808.7.1 or provide specific recommendations from geotechnical engineer for how to provide alternate setbacks and clearances in accordance with CBC 1808.7.5, Incorporate email recommendations included in calculations into a stamped and signed letter or addenda from the geotechnical engineer. 1017120: Erosion control plan on PC 2358-2014 sheet G-04 does not show any provisions for work at the toe of the slope. Provide erosion control drawings for the improvements at the toe of the slope on either this plan or REV20-1088 and cross reference for clarity: 17. Provide material specifications for geotechnical requirements on the plans. 1017120: Not addressed'. i 8. PrGvide design Grit8ria eR the plaRS tG speGify the Fisk GategGFy, the wind lead based on 96 , Se;emle DesigR Category. ASGE 7, table d.5-1 and Table-1- 19. Submit mapped accelerations parameters Ss and S1 and other seismic design parameters using a website interface tool that queries the U.S. Geological Survey (USGS) Seismic Design Web Services and retrieves the seismic design variables in a report format (i.e, ATC Hazards by Location, OSHPD Seismic Design Maps, ASCE 7 Hazard Tool, etc.) compliant with the current Building Code. 1017120: Seismic parameters include in the Geofirm Response to City Comments, dated 912120 are not consistent with the requirements of ASCE 7-16 or the structural calculations. Site Class F requires site specific response analysis. Values provided are consistent with Site Class D (default) however values for SM1 and SDI should be null perASCE 7, section 11.4.8. Note that seismic design is required of all structures in Seismic Design Category D regardless of Risk Category. 20. Note that the building is Wind Exposure D per ASCE 7, Section 26.7. Surface Roughness D prevails in the upwind direction within a distance of 600 ft for a distance greater than 5,000 ft. 1017120: Provide verification calculations to show that seismic controls the lateral design. 21. justify use Gf R-3.5 fer design ef erdinaFy GaRtileveF GelUPAR lateral fGFGe resisting systern for trellis. 22. Provide ACI 318, chapter 17 compatible anchorage calculations for cantilever column base plates to justify the assumption of fixity for the columns. 1017120: Verify anchorage for loading in the orthogonal direction, perpendicular to the top of the wall: 23. See red marked plans for additional corrections/clarification. 1017120: Reminder, 24. See red marked calculations for additional corrections/clarification. 1017120: Reminder. Note that the geotechnical recommendations for the slough wall have changed between the email included in the original calculation submittal and the Geofirm Response to City Comments, dated 912120. Update the wall design to reflect the updated recommendations. 25. Return all red marked plans and calculations with recheck. 1017120: Reminder. CITY OF NEWPORT BEACH COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 100 Civic Center Drive ( P.O. Box 1768 1 Newport Beach, CA 92658-8915 www.newportbeachca.gov 1 (949) 644-3200 GEOTECHNICAL REPORT REVIEW CHECKLIST Project Description: SFR REAR YARD SPA 46 SF, TRELLIS 347 SF, PATIO 996 SF AND ADDITION OF POOL BATH/STORAGE ROOM 154 SF Title & Date of Report SUPPLEMENTAL GEOTECHNICAL RECOMMENDATIONS FOR PROPOSED POOL BY GEOFIRM DATED APRIL 29, 2020 Project Address: 3235 OCEAN BLVD NB Plan Check No.: 1249-2020 Permit App. Date: 7/13/2020 Permit App. Expires: 1/9/2021 CY Cut/Fill: 2015/204 Permit Valuation: $61,119 Adjusted Valuation: $62,000 Consultant: GEOFIRM, INC. Phone:_ 949-494-2112 Applicant/Contact: BRION JEANNETTE ARCHITECT. Phone: 949-645-5854 Plan Check Engineer: Sergio Gutierrez Phone: 949-644-3213 Engineer email: sgutierrez@newportbeachca.gov X 1 st Review: 7/20/2020 X 2nd Review: 1011311010 31d Review: Italic comments F� By Appointment The project plans were reviewed for compliance with the following codes and standards: 2019 CRC; 2019 CBC; 2019 CPC; 2019 CEC; 2019 CMC; 2019 California Energy Code; 2019 California Green Building Standards Code (CG); & Chapter 15 of the Newport Beach Municipal Code (NBMC). The code section references are from the 2019 CBC, unless otherwise stated. • TO EXPEDITE PROJECT APPROVAL: Please provide a written response indicating how and where each comment was resolved on the plans. • Resubmit all previously reviewed plans, updated plans and supporting documents with each subsequent review. • AFTER 2°d PLAN REVIEW: Please call the geologist listed above to schedule a plan review appointment, to expedite project approval. • For clarification of any plan review comment, please call the plan check engineer listed above. • Plan review status is available online at www.new ortbeach, ov. Project status is also available using the interactive voice response system at 949-644-3255, or by speaking with a permit technician at 949-718-1888 during business hours. CorrLists\GeotechnicalReportReviewChecklist 10/13/2020 1 PRIOR TO APPROVAL OF THE REPORT, ATTEND TO THE ITEMS BELOW: 1. Please respond to Plan Check review #REV20-1088 and Building review checklist. 2. Please provide caisson pool foundation parameters for structural engineering foundation design. 3. Please review the Grading, Foundation and Landscape Plans for compliance with geotechnical recommendations of this report. Limitations of Review: Our review is intended to determine if the submitted report(s) comply with City Codes and generally accepted geotechnical practices within the local area. The scope of our services for this third party review has been limited to a brief site visit and a review of the above -referenced report and associated documents, as supplied by this City of Newport Beach. Re -analysis of reported data and/or calculations and preparation of amended construction or design recommendations are specifically not included within our scope of services. Our review should not be considered as a certification, approval or acceptance previous consultant's work, or is meant ad an acceptance of liability for final design or construction. CorrLists\GeotechnicalReportReviewChecklist 10/13/2020 2 APPENDIX C SUPPLEMENTAL GEOTECHNICAL RECOMMENDATIONS FOR PROPOSED POOL �011111= = M C=31rmmlmn 801 Glenneyre St. s Suite F ® Laguna Beach ® GA 92651 (949) 494-2122 ® FAX (949) 497-0270 April 29, 2020 Revised June 19, 2020 KAZ Investment Management c/o Brion Jeannette Architecture 470 Old Newport Boulevard Newport Beach, California 92663 Project No: 72370-01 Report No: 20-8705R Attention: Mr. Martin Bard Subject: Supplemental Geotechnical Recommendations for Proposed Pool New Single -Family Residence 3235 Ocean Boulevard Corona Del Mar, California References: 1. Geofirm, 2013, "Update Preliminary Geotechnical Investigation, Proposed New Single -Family Residence, 3235 Ocean Boulevard, Corona del Mar, California", Project No. 71879-01, Report No. 13-7345r, dated September 12. 2. Geofirm, 2014, "Update Preliminary Geotechnical Recommendations for Project Design Revisions, Proposed New Single -Family Residence, 3235 Ocean Boulevard, Corona del Mar, California", Project No. 71879-01, Report No. t4- 7479, dated May 21. Dear Mr. Bard, In accordance with the request of your pool engineer, this letter presents supplemental geotechnical recommendations the design and construction of the proposed pool at the subject property. The recommendations presented herein are based on our referenced reports and our review of the architectural design plans prepared by Brion Jeannette Architecture. This letter presumes the areas around the pool will be remedial graded with a 3 feet thick layer of soil cement. Earth pressure forces acting on the pool walls should be designed using an equivalent fluid density of 35 pounds per cubic foot for onsite beach deposits. These recommendations may be modified pending verification of soil conditions during construction. Surcharge loads, both topographic and structural, should be considered by the pool engineer. Exploratory drilling on nearby property encountered groundwater at depth of approximately 5 feet below ground surface. This groundwater level is anticipated to experience some fluctuation in response to the tidal cycle and/or during periods of heavy rain. The design groundwater level is recommended to be equal to the maximum predicted tide elevation during heavy rainfall, or an elevation of 7 feet (NAVD 88). Given the bottom of the pool is anticipated at elevation 10.35 feet, with a 12-inch thick shell, the base of the pool shell is approximately 21 feet above the April 29, 2020 Revised June 19, 2020 Project No: 72370-01 Report No: 20-8705R Page No: 2 anticipated high groundwater. Given the close proximity to a possible high groundwater condition, a hydrostatic relief valve may be recommended. If utilized, a gravel filled trench which extends parallel to the long dimension of the pool and connects to the hydrostatic relief valves should be provided. The gravel should be wrapped in filter fabric. Caisson foundations are being considered to support the proposed vanishing -edge pool to mitigate differential settlement. Caisson utilized for proposed pool support should be a minimum 24-inch diameter and embedded into competent bedrock a minimum depth of 5 feet. Caissons may be designed for a dead plus live load end bearing value of 8,000 pounds per square foot for bedrock. The values may be increased by one-third for wind and seismic forces. A skin friction of 300 pounds per square foot may also be utilized for bedrock. Lateral resistance may be computed utilizing 150 or 400 pounds per square foot per foot of depth for beach deposits or bedrock. Settlement of caisson foundations in bedrock is anticipated to be less than 1/4 inch. Thank you for this opportunity to be of service. If you have any questions, please contact this office. Respectfully submitted, r"! 'WAftpj� No. ROE 80190 Zi Wang, R.C.E .09l3tQ Senior Engineer, R.C.E. 8 Cav► Date Signed: 6 / 19 / 2020 't CA&W KAT/ZW:np Distribution: Addressee Via Email APPENDIX D LIQUEFACTION ANALYSIS LIQUEFACTION ANALYSIS 72370-1.0 Hole No.= Water Depth=5 ft Magnitude=7 Acceleration=0.712g Shear Stress Ratio Factor of Safely Settlement Soil Description Raw Unit Fines (ft) 0 1 0 1 5 0 (in.) 10 SPT Weight % 0 Cement -Treated 8 115 NoLq i 2 i Beach Deposits i 4 8 115 0 s i i 8 j i i fs1- , i S = 2.51 in. 10 8 115 0 CRR -- CSR fs1---- Saturated --- E Shaded Zone has Liquefaction Potential Unsaturat. — 12 F U a 14 Stonev-Miller Consultants, Inc. 3235 Ocean Blvd, CDM Plate D-1 Date(s) Logged: 3/1/2010 Method of Drilling: 8 inch Hollow stem auger Logged By: JLH Ground Elev.: 89 Drilling Company: Scott's Drilling LOCATION: 3235 Ocean Blvd Drop: 30-inches Newport Beach CA (Corona Del Weight(s): 140 - Pounds Mar) ❑ - o m a) a 5 @ Z)c4 Q �n � in o � .o o 20 oQ a � -❑ r BORING NO.: HSA-1 Description Attitude L ❑ 0 --- 2.5 6.1 4.2 3.4 — 99.8 103.2 101.8 98.1 — ARTIFICIAL FILL (0-1.5'): @0-1.5': SAND; dark brown, medium grained MARINE TERRACE DEPOSITS (1.5-3h @1.5': SAND; loose to medium dense, slightly moist, medium reddish brown, well sorted, well rounded grains @10.5': SAND; very dense, slightly moist, dark reddish brown, minor discontinuous clay laminae (tiger stripping), well sorted @15': SAND; same lithology as above, increasingly moist @20': SAND; same lithology as above @30': SAND; light golden tan, decreasing d discontinuous clay laminations with depth toward parent material — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — MONTEREY FORMATION (33-33.1) @33': SANDSTONE; very hard to cemented, refusal ------- 0 5 5 10 10 -- 15 15 20 20 — 25 25 30 30 35 35 TOTAL DEPTH 33 FEET NO GROUNDWATER HOLE BACKFILLED WITH DRILL TAILINGS - 0 ^0 Project No.: 71879-00 LOG OF BORING Figure No=B-i r Geofirm Date(s) Logged: 5/9/2018 Method of Drilling: 6" Solid Stem Auger Logged By: JPH Drilling Company: Native Drop: 30"LOCATION: DVeight(s): 3309 Ocean Blvd., Corona del Mar 140 pounds Ground Elevation: ± 89' c W -0 ° o v- BORING NO.: B-1 LP � N (0 c: U CL — N o o E� L c o o_ Description Laboratory Y a a) ❑ W v m = ❑ cn 5 m o 2 0 �, ❑ Tests ❑ Undocumented Fill - "" 0 ML/SM Fine SAND; loose; dry, light brown, very fine- to fine-grained, some scattered angular bedrock fragments to ± 1/2", some roots, minor 1 4.1 visible pinhole porosity, 2 2 ..3..... ML/SM 9 — — — 1.4 -- 104.5 -------------------------------- Terrace Deposits - „3,„ 12 @ T: Fine micaceous SAND; loose, friable, damp, orange -brown, 4 18 very fine- to fine-grained, clean, trace to some roots, "" 4 5 5 B 3 1.8 100.7 @ 6': Fine SAND; loose, dry, light orange -brown, very fine to fine- B 7 grained, clean, slightly micaceous, some poorly indurated zones, 7 9 7 8 8 8 4.1 110.2 @ 9': Fine SAND/silty fine SAND; dense, poorly indurated and very 10 "" 14 x friable, damp, orange -brown to brown, very fine to fine-grained, 30 crude layering apparent. 10.. 12„ 12' ,13,,,, "13" 15 6.4 106.7 @13': Fine SAND/silty fine SAND; dense, slightly indurated and 23 very friable, slightly moist, orange -brown, very fine- to fine- 4 "' 30 30 grained, slightly micaceous, 14 ' 15 15 16 ,,,, 10 3.8 103.2 @16': Fine SAND/silty fine SAND; dense, slightly moist, orange- ' 16 „ 16 brown, very fine- to fine-grained, slightly micaceous. 17 30 17" 18 19 5 @ 19': Fine SAND; dense, slightly moist, orange -brown. 19, 17 3.0 101,6 20 ,,,, 30 20 „ Project No.: 72341-01 LOG OF BORING Figure No.: B-1 Boring Logs.xlsx 6/1/2018 G@ofirm Date(s) Logged: 5/9/2018 Method of Drilling: 6" Solid Stem Auger Logged By: JPH Drilling Company: Native 30" Drop: rop:ht(s): LOCATION: 3309 Ocean Blvd., Corona del Mar � 140 pounds Ground Elevation: ± 89' c ro .0 E o BORING NO.: B-1 a) L °' `° � F � °i Continued 2) a n o m o� u, a M : a) o o Description Laboratory Q o C/5 m� cn m 2 U c 0 Tests o .20,,, „20, -21„ .21. ,22,,,. 9 .,22. 4.3 98.3 @ 22': Micaceous fine SAND; dense, slightly indurated and very 50 friable, slightly moist, light yellow to orange -brown, very fine- grained.. " 23 - 24 ,-, „ 24 , 25 5 @ 25': SAND; dense, very friable, slightly moist, yellow to orange- 25 16 3.2 101.0 brown, fine-grained, clean, slightly micaceous. 26,,, 32 26, ' 27 ". Total Depth - 26.5' 27 No Groundwater Caving - 20-22' 28 "" Boring Backfilled with Cuttings " 28' .29„ „29' .30,.. 30. 31. „31' 32„ „32 33,., '33" 34 „ 34 35 ,, „ 35 ' 36 ,.., „ 36 . '37,,, '37, 38 . 38 .. ']9" 39. „ 4011 ., Project No.: 72341-01 LOG OF BORING Figure No.: B-2 Boring Logs.xlsx 6/1/2018 Geofirm Date(s) Logged: 5/9/2018 Method of Drilling: 6" Hollow Stem Auger Logged By: JPH Drilling Company: Native Drop: : 30" LOCATION: 3309 Ocean Blvd., Corona del Mar t(s): 140 pounds Ground Elevation: ± 13' c Q CL o BORING NO.: B-2 o C o� + E o o U Q Description Laboratory a ❑ 1 U)0 m ❑cn m :Ev 5❑ Tests ❑ 01,111, Undocumented Fill Soils - 0 @ 2.5': Fine SAND; loose, slightly moist, brown, fine-grained, 1' slightly micaceous, scattered cobble size rock/concrete fragments. 1 2 2 3 ,,,,,, ------- -- -- ------ ------------------------------- Beach SAND Deposit - 3 4 4 5 @ 5': Clean SAND; loose, slightly moist, light brown, fine- to 5 medium -grained. 6 6 Lagg deposit; refusal on cobbles, Total Depth 55 8 8 9 9 10 10 11, 11' '12,,, 12, 13,„ 13„ '14„ 14, 15 15- 16' 16' 18 '19„ 19 '20,,,, 20„ Project No.: 72341-01 LOG OF BORING Figure No.: B-3 Boring Logs.xlsx 6i1/2018 Geofirm Date(s) Logged: 10/15/2009 Method of Drilling: 8 - inch Hollow Stem Auger Logged By: JLH Drilling Company: Scott's Drilling Address: 3225 Ocean Blvd. Corona Del Mar Drop: 30-inch Location: Lower Driveway Weight(s): 140# Standard ;Z N 3 0 �, ; a � E E 0) a = ov .N a = _ BORING NO.: HSA-1 Description Attitude 5 5 --- 15 21 16 26 50/5" 3.7 4.3 — 4.8 4.4 4.1 5.2 12.2 98.4 — 102.4 103.2 99.6 101.5 91.2 FILL (0471: @ 0-7': Very fine-grained SAND; loose, slightly moist/dry, medium dark brown, scattered roots, well -sorted, well-rounded, — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — MARINE TERRACE DEPOSITS: @ 7': Coarse SAND; slightly moist, medium dense, medium reddish -brown, well -sorted, well-rounded grains, minor roots. @ 23-24': Mafic-rich, coarse -grained, pebbly SAND; dark gray, scattered well-rounded gravel clasts. @ 25.5': Coarse SAND with gravel; dense, slightly clayey, mafic-rich, scattered, well-rounded silicious sandstone pebbles/cobbles, refusal on cobble. Inferred bedrock contact below. ------- o 5 5 — 10 10 15 15 i i i i 20 20 I t i ' 25 s 25 >' TOTAL DEPTH 26' NO GROUNDWATER BACKFILLED WITH TAILINGS ? � 30 30 Project No.: 71862-00 LOG OF BORING Figure No.: B-11 Geofirm Date(s) Logged: 10/15/2009 Method of Drilling: 6 - inch Solid stem auger Logged By: JLH Drilling Company: DPR Corp. INC. Address: 3225 Ocean Blvd. Corona Del Mar Drop: 30-inch Location: Planter Weight(s): 140# Standard 0 o 3 in v Z)(n ro v Y c m 2U •N a = c0 BORING NO.: SS-1 Description Attitude L ° 0 --- — — — BEACH DEPOSITS (0-10.5'): @ 0-10': Medium SAND; well-rounded, well -sorted, light to medium brown, quartzo-feldspathic, slightly moist, medium loose to dense, cohesionless. @ 10-10.5': Scattered well-rounded cobbles. BEDROCK: MONTEREY FORMATION @ 10.5-1 T: Thinly bedded shale, locally siliceous. Very hard (refusal). ------- 0 5 5 10 10 -- TOTAL DEPTH 11' GROUNDWATER @ 5' BACKFILLED 15 15 Project No.: 71862-00 LOG OF BORING Figure No.: B-11 Geofirm --�`' m O 801 Glenneyre St. • Suite F • Laguna Beach • CA 92651 (949) 494-2122 • FAX (949) 497-0270 September 2, 2020 KAZ Investment Management Project No: c/o Brion Jeannette Architecture Report No: 470 Old Newport Boulevard Newport Beach, California 92663 Attention: Mr. Martin Bard Subject: Response to City of Newport Beach Grad%Wffi)pjQip S4an Review Comments, 1s' Review and Building Plan Review Comments, dated July 20, 2020 Residential Rear Yard Improvement OCT 6 2020 3235 Ocean Boulevard Corona Del Mar, California By' M,K Plan Check No. 1249-2020 72370-10 20-8764 This letter is in response to the City of Newport Beach, Planning Department and Grading/Drainage Plan Check Corrections, dated July 20, 2020. This review requested additional information on six comments. A copy of the review sheets is provided in Appendix A. Our response is presented following each comment. Building Department Plan Review Comments: Item 10: Soil engineer to review and approve final foundation plan, foundation details, shoring plan, pool plan, precise grading and drainage plan and erosion plan. This correction will remain until the permit is issued. Response: Acknowledged. Item 15: Geotechnical report does not provide any recommendations for construction of habitable buildings in the beach deposits and slopewash at the toe of the slope. Additionally, recommendations for the garage building slab included feet of over - excavation with soil -cement treated fill. Provide updated geotechnical recommendations for pool bath/storage building at toe of slope and speck all required over -excavation and soil strengthening requirements per the geotechnical report on the plans. Provide grading cut showing over -excavation for the new building with respect to the existing slope. Response: No habitable buildings at the toe of the slope is proposed at this point. Based on the current proposed locations of the lower detached garage and pool bath/storage September 2, 2020 Project No: 72370-10 Report No: 20-8764 Page No: 2 building, a 3-foot deep over -excavation and replacement with cement treated compacted fill is recommended in order to provide uniform and tun ation support for the structures. The over -excavation should extend 3 feet )rint of the structures, where practical Soil cement compacted fill should consist of a mixture of the existing beach deposits material with a minimum of 2 percent cement. The fill should be moisture conditioned and compacted in accordance with the recommendations provided in the referenced reports. The limits of remedial grading are indicated on Figure 1. Item 16: Buildings below slopes shall be set a sufficient distance from the slope to provide protection from slope drainage, erosion and shallow failures. Provide sufficient clearance from toe of slope per CBC 1808.7.1 or provide specific recommendations from geotechnical engineer for how to provide alternate setbacks and clearances in accordance with CBC 1808.7.5. Incorporate email recommendations included in calculations into a stamped and signed letter or addenda from the geotechnical engineer. Response: A caisson -supported debris wall system is recommended behind the prolos at storage building to provide a debris catchment area and adequate protection from slope* drainage,' erosion and shallow failures impacting the proposed structure. The debris wall design values were provided in Report 17-8034 dated June 27, 2017. Periodic maintenance behind the debris wall, i.e., cleaning, should be anticipated by the homeowner. As indicated in our updated slope stability analyses presented in Appendix C, the buried pier/caisson system should be designed to resist 2.3 kips per linear foot lateral loading. Caissons uxilized for proposed debris wall should be embedded into rr- competent material a minimum depth of 5 feet. Caissons may be designed for a dead pus live load end bearing value of 2,000 pounds per square foot for competent beach deposits. Lateral resistance may be computed utilizing 150 pounds per square foot per fc caisson dEmeter. Grading/Drainage Plan Review Comments: Item 8: For projects on a slope, adjacent to a slope, with a basement, or project sites which require remedial grading, soils engineer to review and approve the grading plan, foundation plan, and shoring plan (if applicable) to verify that the design is consistent with the geotechnical report recommendations. Soils engineer to stamp these plans with a review stamp asserting compliance with geotechnical report recommendations. This comment will remain lip to and include at the time of permit issuance. Response: Acknowledged. September 2, 2020 Project No: 72370-10 Report No: 20-8764 Page No: 3 Item 20: Soil report shall address the potential of soft or compressible or collapsible or liquefiable soils (Site Classes E and F), and recommend mitigation method if they exist. Response: Remedial grading and cement treated compacted fill recommendations are provided in the response to Item 15. Caisson foundations are being considered to support the proposed vanishing -edge pool to mitigate differential settlement. Caisson design recommendations were provided in Report 20-8705r dated June 19, 2020. Item 21: Soil report shall present seismic site coefficients with supporting documentation. �O• Response: It is our understanding that seismic design is not required for non -habitable structures. Nevertheless, based on the geotechnical data and site parameters, the following is provided by the USGS (ASCE 7-16) to satisfy the 2019 CBC design rritPrin Table 2, Site and Seismic Design Criteria for 2019 CBC Design Recomme 6d Parameters Values Site Class Site Longitude (degrees) Site Latitude (degrees) Ss (g) B S 1 (g) B SMs (g) D SM 1 (g) D SDs (g) D SDI (g) D Fa Fv Seismic Design Category !1 -117 8735 33.5936 1.358 0.481 1.630 -- 1.086 -0.862 1.2 2.5 D This evaluation assumes the fundamental period of vibration of proposed structures does not exceed 0. 5 second The structural consultant should review the above parameters and the California Building code to evaluate the seismic design. ;06" YIA-$ tt•A•`b 7 September 2, 2020 Project No: 72370-10 Report No: 20-8764 Page No: 4 This opportunity to be of service is appreciated. If you have any questions, please call. Respectfully submitted, GEOFIRM _ C��'� KEVIN A. TRIGG y I No.1619 1 4 .d No. ROE 80199 CERTIFIED + * Exp, 09/30/20 Kevin Trigg `P G. l ENGINEERING Zi Wang, R.C.E. 8019 Chief E gineering -eologist, _' OGIST a.�r Senior Engineer �°j, C1V�� o� rrr p fi cA�.�F Date Signed: 9/2/2020 (%' Cpi.� KAT/RCL:hsm Distribution: Email Attachments Figure 1 - Grading Limit Plot Plan Appendix A - References Appendix B - City of Newport Beach Plan Review Comments, dated July 20, 2020 Appendix C - Slope Stability Analyses APPENDIX A REFERENCES APPENDIX A REFERENCES 1. Geofirm, 2014, "Update Geotechnical Recommendations for Project Design Revisions, Proposed New Single -Family Residence, 3235 Ocean Boulevard, Corona del Mar, California", Project No. 71879-03, Report No. 14-7479, dated May 21. 2. Geofirm, 2017, "Response to City of Newport Beach Geotechnical Report Review Checklist dated December 28, 2016, New Single -Family Residence, 3235 Ocean Boulevard, Corona Del Mar, California", Project No. 71879-05, Report No. 17-8002, dated January 18. 3. Geofirm, 2017, "Response to City of Newport Beach Geotechnical Report Review Checklist, Second Review dated February 16, 2017, New Single -Family Residence, 3235 Ocean Boulevard, Corona Del Mar, California", Project No. 71879-05, Report No. 17- 8034, dated June 27, 4. Geofirm, 2020, "Supplemental Geotechnical Recommendations for Proposed Pool, 3235 Ocean Boulevard, Corona Del Mar, California", Project No. 72370-01, Report No. 20- 8705R, dated June 19. APPENDIX B CITY OF NEWPORT BEACH PLAN REVIEW COMMENTS, DATED JULY 202 2020 COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 100 Civic Center Drive i P.O. Box 1768 i Newport Beach, CA 92658-8915 www.newportbeachca.gov i (949) 644-3200 PLAN REVIEW COMMENTS Project Description: SFR — New pool house and retaining wall Project Address: 3235 Ocean Blvd Plan Check No.: 1249-2020 Permit App. Date Plan Reviewer: 7/13/20 Valuation: $61,119 Melissa Kubischta, SE Phone: 949-644-3278 The project plans were reviewed for compliance with the following codes and standards: 2019 CRC; 2019 CBC; 2019 CPC; 2019 CEC; 2019.CMC; 2019 California Energy Code; 2019 California Green Building Standards Code (CG); & Chapter 15 of the Newport Beach Municipal Code (NBMC). 1. Obtain plan review approval from the following: a. Building Division b. Grading C. Planning Division d. Public Works 2. Final drawings which will be approved for permit issuance, shall be signed by the respective design professional (electronic signature is acceptable). This correction will remain until the permit is issued. 3. Projects located within a "High Density Area" require the following form, https:/1www.newportbeachca.gov/Home/ShowDocun)ent?id=64600 reproduced on the title page of the plans with the owner's and contractor's signatures. 4. Update project scope of work to reflect new work not previously permitted that is shown on the plans. Provide complete construction information for spa or remove from scope of work. Include unconditioned pool bath/storage building and trellis in the scope of work. All other grading and drainage must be shown on the drawings for the open permit for the house and grading (plan check 2358-2014). 5. Include basic project information on the cover sheet for the new pool bath/storage building including: Use, Occupancy Category, Number of Stories, Type of Construction, and if the building is Sprinklered or Not Sprinklered. 6. Floor plan for the new building should show electrical/mechanical components including required receptacles and exhaust fan for bath. 7. Add note to plans to indicate all grading and drainage per plan check 2358-2014 8. Note that this plan check will not be approved until REV20-1088 to plan check 2358-2014 is approved. 9. Note that Sheets G-1, G-2.1 and L-1 have been removed from this set and incorporated into REV20-1088 for plan check 2358-2014. Note that this permit will not be approved until the approved drawings for the open permit under plan check 2358-2014 are revised to reflect the updated site plan, landscape plan, and grading/drainage requirements including the new pool bath/storage building and trellis. 10. Soils engineer to review and approve final foundation plan, foundation details, shoring plan, pool plan, precise grading and drainage plan and erosion plan. This correction will remain until the permit is issued. 11. Sprinklers: a Sprinklers shall be installed to protect all areas of a dwelling unit including bathrooms more than 55 square feet in area. (R313.3.1.2) b Sprinkler drawings and hydraulic calculations to be submitted to plan check and approved prior to issuing a building permit, or, list under `Deferred Submittals" on cover sheet. Provide a note on the drawing stating: "Obtain fire sprinkler permit prior to calling for roof sheathing inspection." c Revise building data on cover sheet to identify that building is equipped with a fire sprinkler system in accordance with NFPA 13D. 12. Handrails shall satisfy the following: a. Provide a minimum of one continuous handrail on stairways with 4 or more risers and at all open sides. R311.7.8 b. Handrail height shall be 34" to 38" above the nosing of treads. R311.7.8.1 C. Handrail with circular cross -sections shall have a diameter of I %" to 2". R311.7.8.5 item 1. d. Handrails with other than circular cross -sections shall have a perimeter of 4" to 6%4" with a maximum cross-section dimension of 2'/4'. R311.7.8.5 item 1 e. Handrails with a perimeter greater than 6%4' shall comply with R311.7.8.5 item 2. f. Handrail shall be continuous without interruption by newel post or other obstruction, except at the landing, volute, or turnout on lowest tread. R311.7.8.4, Exception 1 & 2. g. Clear space between handrail and wall shall be 11/" minimum. R311.7.8.3 13. Provide roofing specifications (ESR Report or other approved listing), including roof assembly fire classification, on the plans. Roof covering: a. Provide Class B fire classification for new and reconstructed structures. NBMC 15.06.210 14. Where drains and overflow are required, provide detail showing overflow piped separately and 2" higher than roof drain. R903.4.1 15. Geotechnical report does not provide any recommendations for construction of habitable buildings in the beach deposits and slopewash at the toe of the slope. Additionally, recommendations for the garage building slab included 5-feet of overexcavation with soil -cement treated fill. Provide updated geotechnical recommendations for pool bath/storage building at toe of slope and specify all required overexcavation and soil strengthening requirements per the geotechnical report on the plans. Provide grading cut showing overexcavation for the new building with respect to the existing slope. 16. Buildings below slopes shall be set a sufficient distance from the slope to provide protection from slope drainage, erosion and shallow failures. Provide sufficient clearance from toe of slope per CBC 1808.7.1 or provide specific recommendations from geotechnical engineer for how to provide alternate setbacks and clearances in accordance with CBC 1808.7.5. Incorporate email recommendations included in calculations into a stamped and signed letter or addenda from the geotechnical engineer. 17. Provide material specifications for geotechnical requirements on the plans. 18. Provide design criteria on the plans to specify the risk category, the wind load based on 96 mph, all seismic force resisting systems and associated R and Q values, and identify the Seismic Design Category. ASCE 7, table 1.5-1 and Table 12.2-1. 19. Submit mapped accelerations parameters Ss and S1 and other seismic design parameters using a website interface tool that queries the U.S. Geological Survey (USGS) Seismic. Design Web Services and retrieves the seismic design variables in a report format (i.e. ATC Hazards by Location, OSHPD Seismic Design Maps, ASCE 7 Hazard Tool, etc.) compliant with the current Building Code. 20. Note that the building is Wind Exposure D per ASCE 7, Section 26.7. Surface Roughness D prevails in the upwind direction within a distance of 600 ft for a distance greater than 5,000 ft. 21. Justify use of R=3.5 for design of ordinary cantilever column lateral force resisting system for trellis. 22. Provide ACI 318, chapter 17 compatible anchorage calculations for cantilever column base plates to justify the assumption of fixity for the columns. 23. See red marked plans for additional corrections/clarification. 24. See red marked calculations for additional corrections/clarification. 25. Return all red marked plans and calculations with recheck. 2 MI C COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 100 Civic Center Drive I P.O. Box 17681 Newport Beach, CA 92658-8915 www.newportbeachca.gov 1 (949) 644-3200 GRADING/DRAINAGE PLAN REVIEW COMMENTS Project Description: SFR REAR YARD SPA 46 SF, TRELLIS 347 SF, PATIO 996 SF AND ADDITION OF POOL BATH/STORAGE ROOM 154 SF Project Address: 3235 OCEAN BLVD NB Permit App. Date: 7/13/2020 CY Cut/Fill: 2050/308 Permit Valuation: $61,119 Architect/Engineer: DZNE,INC. Applicant/Contact: JEANNETTE BRION S Plan Check Engineer: Sergio Gutierrez Engineer email: sgutierrez newportbeachca.gov )( 1 st Review: 7/20/2020 2nd Review: Italic comments Plan Check No.: 1249-2020 Permit App. Expires: 1/9/2021 Adjusted Valuation: $ Phone: 949-3058920 Phone: 949-645-5854 Phone: 949-644-3213 31d Review: [—� By Appointment The project plans were reviewed for compliance with the following codes and standards: 2019 CRC; 2019 CBC; 2019 CPC; 2019 CEC; 2019 CMC; 2019 California Energy Code; 2019 California Green Building Standards Code (CG); & Chapter 15 of the Newport Beach Municipal Code (NBMC) The code section references are from the 2019 CBC, unless otherwise stated. • TO EXPEDITE PROJECT APPROVAL: 'Please provide a written response indicating how and where each comment was resolved on the plans. • Resubmit all previously reviewed plans, updated plans and supporting documents with each subsequent review. • AFTER 2nd PLAN REVIEW. Please call the plan check engineer listed above to schedule a plan review appointment, to expedite project approval. • For clarification of any plan review comment, please call the plan check engineer listed above. • Plan review status is available online at www.newoortbeachca.gov. Project status is also available using the interactive voice response system at 949-644-3255, or by speaking with a permit technician at 949-718-1888 during business hours. Correction Lists\Grading/DrainagePlanRevComment 07/20/20 1 GENERAL All permits related to the proposed project shall be issued at the same time, or separate plans and plan review will be required for items not issued with this review. Provide additional permit worksheets for the following: a. Accessory structures, detached patio covers and trellises, b. Detached or free-standing trash enclosures, C. Masonry or concrete fences over 3.5 ft high, d. Retaining walls over 4 ft high from the bottom of the foundation to the top of the wall. 2. Obtain plan review approval from the following: a. Planning Department, b. Public Works Department, Final drawings which will be approved for permit issuance shall be signed by the respective design professionals (electronic signature is acceptable). This comment will remain up to and include at the time of permit issuance. SURVEY CORRECTIONS: 4. Provide a site survey, stamped and signed by a State Licensed Land Surveyor or authorized Civil Engineer (License Number below 33,966). Provide note on plan, "Surveyor or engineer shall permanently monument property corners or offsets before starting grading." Specify benchmark used for survey. Provide elevations at the following locations: a. All property corners. b. Around existing structure(s) at corners, including corners at jogs of exterior walls. C. At interior finish floor elevations. d. At bottom of all site walls. Indicate wall height. e. At bottom of elevated planters. Indicate planter height. f. At maximum spacing of 25' along the length and width of the property on all sides of an existing structure. g. Elevation contours for sloping sites every one foot elevation change. h. Three elevations (min.) equally spaced in the side yard of adjacent properties. i. Three elevations along the flow line in gutter and alley adjacent to site. GRADING CORRECTIONS: Please Refer to PC # REV20-1088 for Grading/Drainage redlines prior to approval of this PC# 1249-2020 7. Two stamped and signed sets of plans are required for permit issuance (electronic signature is acceptable). This comment will remain up to and include at the time of permit issuance. 8. For projects on a slope, adjacent to a slope, with a basement, or project sites which require remedial grading, soils engineer to review and approve the grading plan, foundation plan, and shoring plan (if applicable) to verify that the design is consistent with the geotechnical report recommendations. Soils engineer to stamp these plans with a review stamp asserting compliance with geotechnical report recommendations. This comment will remain up to and include at the time of permit issuance, 9. Pursuant to Section 1808.7.4 of the 2019 CBC "the top of any exterior foundation shall extend above the elevation of the street gutter at point of discharge or the inlet of an approved drainage devise a minimum of 12 inches plus 2 percent." Drainage shall conform to Section 15.10.120 (f) of the NBMC. 10. All drainage water from a newly graded or a regraded site shall be directed from a privately owned property directly to the public drainage system to meet 2019 CBC Section1805.4.3 and conform to Section 15.10.120 (E) of the NBMC. CorrectionLists\Grading/DrainagePlanRevComment 07/20/20 2 11. Provide a drainage design that prevents entrance of drainage water from the street/alley onto property. 12. Clearly show elevation of adjacent properties and the distance from property lines to adjacent structures. 13. Design drainage to ensure water does not drain over the top edge of any slopes. 14. Show locations and details of subdrain system(s) and outlet for retaining walls on grading plan when subdrain is required by soils report. Subdrain to be piped separately from site drainage or invert in French drain to be higher than the invert elevation of the nearest drain. 15. Provide erosion and siltation control plans. 16. Provide a section showing required grading cut and proximity to property line. 17. Provide building or structure setbacks from top and bottom of slope as shown in CBC, Fig. 1808.7.1. For descending slopes less than 12 feet in height, minimum setback from competent slope face material shall be 4 feet. 18. Top and toe of slope to be setback from the property line per NBMC 15.10.110B, Fig. 1., 19. Provide two copies of soils and foundation investigation report by a registered civil engineer. 20. Soils report shall address the potential of soft or compressible or collapsible or liquefiable soils (Site Classes E and F), and recommend mitigation method if they exist. 21. Soils report shall present seismic site coefficients with supporting documentation. 22. List soils report recommendations on grading plan. WATER QUALITY CORRECTIONS: 23. This project falls into category circled below. Prepare a Water Quality Management Plan (WQMP) consistent with the model WQMP, Exhibit 7.11 (http://media.ocqov.com/gov/pw/watersheds/documents/wqmp/). A. PRIORITY PROJECTS (Model WQMP Table 7.11-21 i. Impervious surface of 2,500 square feet or more located within or directly adjacent to (within 200 ft,) or discharging directly to receiving water. within environmentally sensitive areas (San Diego Creek, upper and lower Newport Bay, Buck Gully, Los Trancos, Little Corona del Mar Beach, Crystal Cove State Beach). ADDITIONAL CORRECTIONS: 24. See drawings for additional corrections. Please see PC# REV20y1088 Grading sheet redlines to be Irevised: Correction Usts\G radi ng/D rain age Plan RevComment 07/20/20 3 APPENDIX C ENGINEERING. STABILITY ANALYSES APPENDIX C ENGINEERING STABILITY ANALYSES GENERAL Engineering stability analyses were performed to assess the minimum Factors of Safety (FS) against future movement of the slope located within the subject property. The analyses were performed with the actual geologic conditions. The "Slide 7.0", 2D slope stability program utilized the stability analyses. The computer program utilizes the limit equilibrium theory for the calculation of the minimum Factory of Safety (FS). SHEAR STRENGTH PARAMETERS The shear strength parameters utilized in our stability analyses are presented in Table C-1 below. These values were based on site -specific laboratory test results, test results from adjacent sites, local experience in similar soils, and engineering judgment, and are considered reasonable and representative of the on -site materials. TABLE C-1 SUMMARY OF STRENGTH PARAMETERS Material Type Bulk Density Y. (peg Bulk Density 7s (pef) Cohesion C (psi Friction Angle (deg) Beach Deposit — Qb 120 120 0 32 Cement Treated Compacted 120 120 406 32 Fill at Lower Garage Slopewash Deposit — Qsw 120 120 100 28 Monterey Bedrock — Tmsit-sh 125 125 400 28 Monterey Bedrock — Tmss 125 125 600 38 Marine Deposit — Qtm 120 120 100 32 . ANALYSES Slope stability analyses were performed for the slope as presented in Cross Section A -A'. Based on the results of our analyses, we recommend that a caisson -supported debris wall system may be utilized to address global and suriicial instability. The Factor of Safety (FS) criteria adopted for verifying the adequacy of the stability of the slope for the final design are as follows: Static Conditions — FS>1.5 Pseudostatic Conditions — FS>l.l Assumed Lateral Force (Seismic) — 0.15g The results of the analyses are presented in Table C-2 and Figures C-1 through C-2. Any revisions to the grading plans may require additional analyses and revisions to the recommendations presented herein. TABLE C-2 SUMMARY OF STABILITY ANALYSES Section Static Seismic Figure Comments FOS FOS No. 1.53 C-1 proposed Condition, caisson -supported A -A' debris wall 1.19 C-2 I v v v v v v v ^m. 0. m N N m m C O V _O. S O O O Q.. m L O .O L O O- O- O- O- O- O- H v u U V U U u Z O O N • _ 'a E N O - e0 O LO E 41 O - p Q - - - - N i g - C) U C � p 1 - H i m C � - C f0 'N U O r- ... O •L O - o c rn - ? p W - N O > Q O O N -_ m (0 0 m $ C U n O' C m N - Q) U 0 U VI aj IIl > (7� Oh 00 O O ' L CL CpN Ln V l� a v . oLn -0 m ate+ CD �i to �i to in _ V) a v q m m coN N m O v O N 0O C 0 0. v 0 O r� V o o. `c o `c a `c o �v Gl T ~ O t 7 O 3 O 7 O 7 V1 U V U U U u. 40 v�i O vl v) O O sa-j f IO `o�Cl.; -N Q m m z U cl cf `f O N o^ 0 4) O N O tf) (DLf) O Ln CD LC) O Lo O !n O to O t.f) O uO O L O L O ' W O N uO I- O N LO t- O N Ln r- O N N l- O N LO l- O N N l- O O O O O r-I r-I �-1 N N N N M M 1M CM Lr L� L) L. l0 _ - >rLH N s 0 09b 9Zb 0 L 5L 09 4Z r= o -F-1 r-r rY-n 801 Glenneyre St. • Suite F • Laguna Beach • CA 92651 (949) 494-2122 • FAX (949) 497-0270 April 29, 2020 Revised June 19, 2020 KAZ Investment Management c/o Brion Jeannette Architecture 470 Old Newport Boulevard Newport Beach, California 92663 Project No: 72370-01 Report No: 20-8705R Attention: Mr. Martin Bard Subject: Supplemental Geotechnical Recommendations for Proposed Pool New Single -Family Residence 3235 Ocean Boulevard Corona Del Mar, California References: 1. Geofirm, 2013, "Update Preliminary Geotechnical Investigation, Proposed New Single -Family Residence, 3235 Ocean Boulevard, Corona del Mar, California", Project No. 71879-01, Report No. 13-7345r, dated September 12. 2. Geofirm, 2014, "Update Preliminary Geoty,�m oli*endations for Project Design Revisions, Proposed New Single -Family Residence, 3235 Ocean Boulevard, Corona del Mar, California", Project No. 71879-01, Report No. 14- 7479, dated May 21. J U L 1 4 2020 Dear Mr. Bard, BY: M.K. In accordance with the request of your pool engineer, this letter presents supplemental geotechnical recommendations the design and construction of the proposed pool at the subject property. The recommendations presented herein are based on our referenced reports and our review of the architectural design plans prepared by Brion Jeannette Architecture. This letter presumes the areas around the pool will be remedial graded with a 3 feet thick layer of soil cement. Earth pressure forces acting on the pool walls should be designed using an equivalent fluid density of 35 pounds per cubic foot for onsite beach deposits. These recommendations may be modified pending verification of soil conditions during construction. Surcharge loads, both topographic and structural, should be considered by the pool engineer. Exploratory drilling on nearby property encountered groundwater at depth of approximately 5 feet below ground surface. This groundwater level is anticipated to experience some fluctuation in response to the tidal cycle and/or during periods of heavy rain. The design groundwater level is recommended to be equal to the maximum predicted tide elevation during heavy rainfall, or an elevation of 7 feet (NAVD 88). Given the bottom of the pool is anticipated at elevation 10.35 feet, with a 12-inch thick shell, the base of the pool shell is approximately 2f feet above the April 29, 2020 Revised June 19, 2020 Project No: 72370-01 Report No: 20-8705R Page No: 2 anticipated high groundwater. Given the close proximity to a possible high groundwater condition, a hydrostatic relief valve may be recommended. If utilized, a gravel filled trench which extends parallel to the long dimension of the pool and connects to the hydrostatic relief valves should be provided. The gravel should be wrapped in filter fabric. Caisson foundations are being considered to support the proposed vanishing -edge pool to mitigate differential settlement. Caisson utilized for proposed pool support should be a minimum 24-inch diameter and embedded into competent bedrock a minimum depth of 5 feet. Caissons may be designed for a dead plus live load end bearing value of 8,000 pounds per square foot for bedrock. The values may be increased by one-third for wind and seismic forces. A skin friction of 300 pounds per square foot may also be utilized for bedrock. Lateral resistance may be computed utilizing 150 or 400 pounds per square foot per foot of depth for beach deposits or bedrock. Settlement of caisson foundations in bedrock is anticipated to be less than '/a inch. Thank you for this opportunity to be of service. If you have any questions, please contact this office. Respectfully submitted, GEOFIRM r� t Kevin E. Trigg, 1':G. Chief Engineering Geolo KAT/ZW:np ��cE� °ova\ 4(KEVIN A. TRIGG O. 1619RTIFIEDINEERING �OLOGIST �.T t' QA �Fo Distribution: Addressee Via Email Zi Wang, R.C.E` Senior Engineer, R.C.E. 8 Date Signed: 6 / 19 / 2020 -'--o L=— C= ' r'-'• f'T1 801 Glenneyre St. • Suite F • Laguna Beach • CA 92651 (949) 494-2122 • FAX (949) 497-0270 December 23, 2019 KAZ Investment Management Project No: 72370-11 c/o Brion Jeannette Architecture Report No: 19-8660 470 Old Newport Boulevard Newport Beach, California 92663 BUILDING DIVISION Attention: Mr. Martin Bard Subject: Geotechnical Design Plan Review Lower Patio Improvements 3235 Ocean Boulevard By NIX Newport Beach, California CDP Application No. 5-13-0678-A1 References: 1. Geofirm, 2019, "Response to California Coastal Commission, Notice of Incomplete Application dated June 18, 2019, New Single -Family Residence, 3235 Ocean Boulevard, Newport Beach, California" 2. Brion Jeannette Architecture, 2018, "Oceanview, 3235 Ocean Blvd. Corona Del Mar, CA", Sheets A-1 and A-3, Job No. 18-026, undated. Dear Mr. Bard, It is our understanding the California Coastal Commission is requesting a geotechnical review of the City establishing the 15 foot contour as the toe of slope landward of Breakers Drive, below the subject site. I've tried to find a definition or determine a criteria that is used by the Commission to establish a "toe" of bluff, but cannot find one. The toe of bluff seems like an obvious geologic feature. Geologically it would be the landward contact of the holocene beach sand deposits with the ascending bluff slopewash or the bedrock. Our office mapped this line on many Ocean Blvd projects, including in our Update report for the Tannir project, as just seaward of the 15 foot contour (refer to Plate 1). It appears the City may have used that contact to define it, and that seems appropriate and reasonable. Regarding potential hazards, it is outside the tsunami zone, and with 150'+ of protective beach it is unlikely to be impacted by erosion from sea -level rise. Our office has geotechnically approved the improvements as proposed. Let me know if there is anything else that is needed. This opportunity to be of continued service is appreciated. If you have any questions, please contact this office. GEOFIRM Kevin' Tti 4l,g; Chief Lgineering Geologist, Date Signed: 12/23/2019 KAT/ZW:np RE G. ' 610 o�o��N KEVIN A. TRIGG `h * NO. 1619 CERTIFIED ENGINEERING GEOLOGIST F QF OA1-�FQ Distribution: (5) Addressee Attachments: Appendix A - References Zi Wang, R.C.E, 801 Senior Engineer Date Signed: 12/23/2019 11% No. ROE 80199 Exp, 09/30/20 APPENDIX A REFERENCES APPENDIX A REFERENCES REPORTS Geofirm, 2013, "Update Preliminary Geotechnical Investigation, Proposed New Single - Family Residence, 3235 Ocean Boulevard, Corona del Mar, California", Project No. 11 71879-01, Report No. 13-7345r, dated September 12. 2. Geofirm, 2017, "Response to City of Newport Beach Verbal Geotechnical Review Dated July 13, 2017, New Single -Family Residence, 3235 Ocean Boulevard, Corona Del Mar, California", Project No. 71879-05, Report No. 17-8116, dated July 13. 3. Geofirm, 2018, "Rough Grade Earthwork Observation Report, New Single -Family Residence, 3235 Ocean Boulevard, Corona Del Mar, California", Project No. 72370-10, Report No. 18-8421, dated October 24. PLANS A. Brion Jeannette Architecture, "Driveway Site Walls Plans, Oceanwiew, 3235 Ocean Boulevard, Corona del Mar, California", Sheets A-1 to A-5 of 6, Project No. 18-026, Undated.