HomeMy WebLinkAboutX2019-2215 - MiscReport of Special Inspection
project Nand & Address Michael Garet /2627 Ragueta
Permit N, c�.- X2019-1831
Inspectio r. -y Pe(s) Epoxy
Inspection Da:c(s) 7/29/19 [ ) Periodic [ X ) Continuous
Describe Insp=tioc ,'lade, ir.clading Locations:
Arrived on site to provide continuous special inspection during the epoxy all thread installation at (34) retro fitted bolts. 5/8"
diameter all thread were installed per details on sheet 3 of contract documents. Contractor used Simpson SET XP, lot # 1000037334,
expires 04/10/21 and is placed in compliance with ESR 2508. Verified hole depth, diameter and cleanness. Observed the epoxy
injection and dowel installation in accordance with the manufacturer instructions.
Total Inspection Time Each Day:
Date
Hour
List Items Rccuiring Correction., include uncorrected items previously listed
Comments:
Tot- best of .r.y i; na.v;edge, the wok inspected was in accordance with the Building Department
-:^rovcd des:,-n dra•,vings, specifications and applicable werl:mznship provisions of tSe U.B.C.
cYcCnt as noted above.
Dat:
7/29119
Full Name; Michael Vidovich Reeistration No. iVB40664
FCP..`--! StA Ar
?Sl:
Project Name
Project Address
Contractor
Subcontractor
_ Concrete
Structural Steel
HORELIHE
v SPECIAL INSPECTION
I N C O R P O R A T E D
Michael Garst
2627 Raqueta, Newport Bea
anerholt Construction & Int
YFC Builders
Pre -Stressed Concrete
Fire Proofing
Date
Permit #
Architect
Masonry
Other
Description of work observed
7/29/19
X2019-1831
Hansen - Hokama
X Epoxy Wood
Arrived on site to provide continuous special inspection during the epoxy all thread installation at (34)
retro fitted bolts. 5/8" diameter all thread were installed per details on sheet 3 of contract documents.
Contractor used Simpson SET XP, lot # 1000037334, expires 04/10/21 and is placed in compliance with ESR
2509. Verified hole depth, diameter and cleanness. Observed the epoxy injection and dowel installation in
accordance with the manufacturer instructions.
NOTICE: I hereby cent!);y that, at the time of this inspection, I have observed all of the above reported work, unless otherwise noted. Tothe best
of my knowledge and belief, I have found this work to comply with the approved plans, specifications, and applicable section(s) of the governing
Building Code, as applicable to the municipality where this project is located This report cannot be constructed to be a recommendation of work
of et c nature to r performed. It should be noted that our presence and the services provided do not relieve the contractor from its obligation to
meet contractual requirements.
Red. Hrs.: 4 The Owner or a successor in interest shall hold harmless Shoreline Special Inspection, Inc., a
O.T. Hrs. California Corporation, from any and all legal proceedings ofany nature whatsoever, that are related
Test Cyls : to the inspection services provided in this report. Should Shoreline Special Inspection, Inc. be required
to institute legal action, for the collection of a debt incurred as a result of the acceptance of this report,
Type : Shoreline Special Inspection, Inc. shall be entitled to Attorney's fees and costs incurred in said action.
Michael Vidovich
Inspector/Technician Name NB-0664
Ins ector/Technician Si nature
854 Blue Heron Drive San Marcos, CA 92078 619-206--3884 ation #