Loading...
HomeMy WebLinkAboutX2019-2215 - MiscReport of Special Inspection project Nand & Address Michael Garet /2627 Ragueta Permit N, c�.- X2019-1831 Inspectio r. -y Pe(s) Epoxy Inspection Da:c(s) 7/29/19 [ ) Periodic [ X ) Continuous Describe Insp=tioc ,'lade, ir.clading Locations: Arrived on site to provide continuous special inspection during the epoxy all thread installation at (34) retro fitted bolts. 5/8" diameter all thread were installed per details on sheet 3 of contract documents. Contractor used Simpson SET XP, lot # 1000037334, expires 04/10/21 and is placed in compliance with ESR 2508. Verified hole depth, diameter and cleanness. Observed the epoxy injection and dowel installation in accordance with the manufacturer instructions. Total Inspection Time Each Day: Date Hour List Items Rccuiring Correction., include uncorrected items previously listed Comments: Tot- best of .r.y i; na.v;edge, the wok inspected was in accordance with the Building Department -:^rovcd des:,-n dra•,vings, specifications and applicable werl:mznship provisions of tSe U.B.C. cYcCnt as noted above. Dat: 7/29119 Full Name; Michael Vidovich Reeistration No. iVB40664 FCP..`--! StA Ar ?Sl: Project Name Project Address Contractor Subcontractor _ Concrete Structural Steel HORELIHE v SPECIAL INSPECTION I N C O R P O R A T E D Michael Garst 2627 Raqueta, Newport Bea anerholt Construction & Int YFC Builders Pre -Stressed Concrete Fire Proofing Date Permit # Architect Masonry Other Description of work observed 7/29/19 X2019-1831 Hansen - Hokama X Epoxy Wood Arrived on site to provide continuous special inspection during the epoxy all thread installation at (34) retro fitted bolts. 5/8" diameter all thread were installed per details on sheet 3 of contract documents. Contractor used Simpson SET XP, lot # 1000037334, expires 04/10/21 and is placed in compliance with ESR 2509. Verified hole depth, diameter and cleanness. Observed the epoxy injection and dowel installation in accordance with the manufacturer instructions. NOTICE: I hereby cent!);y that, at the time of this inspection, I have observed all of the above reported work, unless otherwise noted. Tothe best of my knowledge and belief, I have found this work to comply with the approved plans, specifications, and applicable section(s) of the governing Building Code, as applicable to the municipality where this project is located This report cannot be constructed to be a recommendation of work of et c nature to r performed. It should be noted that our presence and the services provided do not relieve the contractor from its obligation to meet contractual requirements. Red. Hrs.: 4 The Owner or a successor in interest shall hold harmless Shoreline Special Inspection, Inc., a O.T. Hrs. California Corporation, from any and all legal proceedings ofany nature whatsoever, that are related Test Cyls : to the inspection services provided in this report. Should Shoreline Special Inspection, Inc. be required to institute legal action, for the collection of a debt incurred as a result of the acceptance of this report, Type : Shoreline Special Inspection, Inc. shall be entitled to Attorney's fees and costs incurred in said action. Michael Vidovich Inspector/Technician Name NB-0664 Ins ector/Technician Si nature 854 Blue Heron Drive San Marcos, CA 92078 619-206--3884 ation #