Loading...
HomeMy WebLinkAboutX2021-0687 - CalcsDESIGN CALCULATIONS FOR: COMMERCIAL MODULAR BUILDING PAD/PIER/ANCHOR SYSTEM (TEMPORARY FOUNDATION SYSTEM) PROJECT: 24' x 40' MODULAR BUILDING LIEBKE ASSOCIATES, INC. 1 HOAG DRIVE NEWPORT BEACH, CALIFORNIA 92663 PREPARED FOR: IWILLSCOT PREPARED BY: CUMEN ENGINEERING DESIGN, LLC 11624 NORTH 151ST LANE. SURPRISE, ARIZONA 85379 (801) 571- 9877 x202(_ O ( �-, Pool 11811 GREENSTONE AVE. SANTA FE SPRINGS, CALIFORNIA 90670 (562) 903 - 9200 MAR 2 4 2021 COVER 1 DESIGN LOADS 2 PAD CAPACITY 7 PAD/PIER SPACING 8 COLUMN SUPPORTS 9 ANCHOR QUANITY 10 APPENDIX A.01 ROOF LIVE LOAD: 20 PSF FLOOR LIVE LOAD: 50 PSF PARTITION LOAD: 15 PSF ULT. WIND SPEED / 115 MPH, EXPOSURE: EXP 'C' ALLOWABLE PAD BEARING CAPACITY: 1500 PSF DESIGN CODE: 2019 CBC SEISMIC FACTOR: 1.00 RISK CATEGORY: II SPECTRAL RESPONSE ACCELERATION: (Ss) 1.500 g (S1) 0.600 g SITE CLASS: D (DEFAULT) PROJECT # 210336 Title to these calculations remains with ACUMEN ENGINEERING DESIGN, LLC. The information herein is for the sole use of WILLSCOT and shall be held confidential. Re -use or reproduction in whole or in part is prohibited. Acumen Engineering Design 11624 North 151st Lane Surprise, Arizona 85379 801-571-9877 JOB TITLE 24' x 40' Commercial Modular • Pad/Pier/Anchor Design JOB NO. SHEET NO. CALCULATED BY DATE CHECKED BY DATE 2 www.struware.com Code Search Code: ASCE 7 - 16 Occupancy: Occupancy Group = B Business Risk Category & Importance Factors: Risk Category = Wind factor = Snow factor = Seismic factor = T_ype_of Construction: Fire Rating: Roof = Floor = Building Geometry: Roof angle (0) Building length (L) Least width (B) Mean Roof Ht (h) Parapet ht above grd Minimum parapet ht Live Loads: I I 1.00 1.00 1.00 0.0 hr 0.0 hr 0.25 / 12 40.0 ft 24.0 ft 14.0 ft 0.o ft 0.0 ft 1.2 deg Roof 0 to 200 sf: 20 psf 200 to 600 sf: 24 - 0.02Area, but not less than 12 psf over 600 sf: 12 psf Floor: Typical Floor 50 psf Partitions 15 psf Acumen Engineering Design 11624 North 151st Lane Surprise, Arizona 85379 801-571-9877 JOB TITLE 24' x 40' Commercial Modular JOB NO. CALCULATED BY CHECKED BY Pad/Pier/Anchor Design SHEET NO. DATE DATE Wind Loads : Ultimate Wind Speed Nominal Wind Speed Risk Category Exposure Category Enclosure Classif. Internal pressure Directionality (Kd) Kh case 1 Kh case 2 Type of roof ASCE 7- 16 115 mph 89.1 mph I I C Enclosed Building +/-0.18 0.85 0.849 0.849 Topographic Factor (Kzt) Topography Hill Height (H) Half Hill Length (Lh) Actual H/Lh = Use H/Lh = Modified Lh = From top of crest: x = Bldg up/down wind? H/Lh= 0.00 x/Lh = 0.00 z/Lh = 0.00 At Mean Roof Ht: Kzt = (1+K1K2K3)^2 = 1.00 Gable Flat 0.0 ft 0.0 ft 0.00 0.00 0.0 ft 50.0 ft downwind Gust Effect Factor h= 14.0 ft B = 24.0 ft /z (0.6h) = 15.0 ft Rigid Structure e = 0.20 £ _ Zmin = c= go, 9v = LZ = Q= Iz = G= K� = 0.000 K2 = 0.000 1(3 = 1.000 H< 15ft;exp C Kzt=1.0 V ) V( (upwind) • Speedup x(downwind) H/2 H/2 H ESCARPMENT V(z) V(Z) x(upwind) .a Speed-up x(downwind) H 2D RIDGE or 3D AXISYMMETRICAL HILL Flexible structure if natural frequency < 1 Hz (T > 1 second). If building h/B>4 then may be flexible and should be investigated. h/B = 0.58 Rigid structure (low rise bldg) G = 0.85 . Using rigid structure default Flexible or Dynamically Sensitive Structure 34 icy (n,) = 0.0 Hz 500 ft Damping ratio ([3) = 0 15ft /b= 0.65 0.20 3.4 427.1 ft 0.94 0.23 0.89 use G = 0.85 /a = Vz = N1 = Kn = Rh = RB = RL = gR = R = Gf = 0.15 97.1 0.00 0.000 28.282 28.282 28.282 0.000 0.000 0.000 n= n= n= 0.000 0.000 0.000 h = 14.0 ft Acumen Engineering Design 11624 North 151st Lane Surprise, Arizona 85379 801-571-9877 JOB TITLE 24' x 40' Commercial Modular Pad/Pier/Anchor Design JOB NO. SHEET NO. CALCULATED BY DATE CHECKED BY DATE Wind Loads - MWFRS h<_60' (Low-rise Buildings) except for open buildings Kz = Kh (case 1) = 0.85 Base pressure (qh) = 24.4 psf GCpi = +/-0.18 Wind Pressure Coefficients Edge Strip (a) = End Zone (2a) = Zone 2 length = 3.0 ft 6.0ft 12.0 ft CASE A CASE B 0=1.2deg Surface GCpf w/-GCpi w/+GCpi GCpf w/-GCpi w/+GCpi 1 0.40 0.58 0.22 -0.45. -0.27 -0.63 2 -0.69 -0.51 -0.87 -0.69 -0.51 -0.87 3 -0.37 -0.19 -0.55 -0.37 -0.19 -0.55 4 -0.29 -0.11 -0.47 -0.45 -0.27 -0.63 5 0.40 0.58 0.22 6 -0.29 -0.11 -0.47 0)U)AW N- mmmmmm 0.61 0.79 0.43 -0.48 -0.30 -0.66 •-1.07 -0.89 -1.25 -1.07 -0.89 -1.25 -0.53 -0.35 -0.71 -0.53 -0.35 -0.71 -0.43 ' -0.25 -0.61 -0.48 -0.30 -0.66 0.61 0.79 0.43 -0.43 -0.25 -0.61 Ultimate Wind Surface Pressures (psf) 1 14.2 5.4 -6.6 -15.4 2 -12.5 -21.3 -12.5 -21.3 3 -4.6 -13.4 -4.6 -13.4 4 -2.7 -11.5 -6.6 -15.4 5 14.2 5.4 6 -2.7 -11.5 0) CT A W N mmmmmm 19.3 10.5 -7.3 -16.1 -21.7 -30.5 -21.7 -30.5 -8.6 -17.3 -8.6 -17.3 -6.1 -14.9 -7.3 -16.1 19.3 10.5 -6.1 -14.9 Parapet Windward parapet = Leeward parapet = 0.0 psf (GCpn = +1.5) • 0.0 psf (GCpn = -1.0) Horizontal MWFRS Simple Diaphragm Pressures (psf) Transverse direction (normal to L) Interior Zone: Wall 16.9 psf Roof -7.8 psf ** End Zone: Wall 25.4 psf Roof -13.2 psf ** Longitudinal direction (parallel to L) Interior Zone: Wall 16.9 psf End Zone: Wall 25.4 psf ** NOTE: Total horiz force shall not be less than that determined by neglecting roof forces (except for MWFRS moment frames). The code requires the MWFRS be designed for a min ultimate force of 16 psf multiplied by the wall area plus an 8 psf force applied to the vertical projection of the roof. Windward roof overhangs = 17.1 psf (upward) add to windward roof pressure WINDWARD OOV ERMANO 5 a WINDWARD ROOF I I 1 I 1 1 1 I ftt LEEWARDr ROOF VERTICAL TRANSVERSE ELEVATION fri WINDWARD ROOF 11I1I1I LEEWARD ROOF r r t t t t t VERTICAL Lf2 or LONE 2 LONGITUDINAL ELEVATION Acumen Engineering Design JOB TITLE 24' x 40' Commercial Modular 11624 North 151st Lane Pad/Pier/Anchor Design Surprise, Arizona 85379 JOB NO. SHEET NO. 801-571-9877 CALCULATED BY DATE CHECKED BY. DATE Seismic Loads: ASCE 7- 16 Strength Level Forces Risk Category : li Importance Factor (I) : 1.00 Site Class : ) - code default Ss (0.2 sec) = 150.00 %g S1 (1.0 sec) = 60.00 %g Fa = Fv = 1.200 Sms = 1.800 SDs = 1.200 • Design Category = D 1.700 Sm1 = 1.020 Sp, = 0.680 Design Category = D Seismic Design Category = D Redundancy Coefficient p = 1.30 Number of Stories: 1 Structure Type: Light Frame Horizontal Struct Irregularities: No plan Irregularity Vertical Structural Irregularities: la ) Stiffness Irregularity —Soft Story Flexible Diaphragms: Yes Building System: Bearing Wall Systems Seismic resisting system: Light framed wall system using flat strap bracing System Structural Height Limit: 65 ft Actual Structural Height (hn) = 14.3 ft See ASCE7 Section 12.2.5 for exceptions and other system limitations DESIGN COEFFICIENTS AND FACTORS Response Modification Coefficient (R) = 4 Over -Strength Factor (Do) = 2 Deflection Amplification Factor (Cd) = 3.5 SDs = 1.200 SD1 = 0.680 Seismic Load Effect (E) = Eh +/-Ev = p QE +/- 0.2SDs D = 1.3Qe +/- 0.240D QE = horizontal seismic force Special Seismic Load Effect (Em) = Emh +/- Ev = Sao QE +/- 0.2SDs D = 2Qe +/- 0.240D D = dead load PERMITTED ANALYTICAL PROCEDURES Simplified Analysis - Use Equivalent Lateral Force Analysis Equivalent Lateral -Force Analysis - Permitted Building period coef. (CT) = 0.020 Cu = 1.40 Approx fundamental period (Ta) = CThn" = 0.147 sec x= 0.75 Tmax = CuTa = 0.206 User calculated fundamental period (T) = sec Use T = 0.147 Long Period Transition Period (TL) = ASCE7 map = 8 Seismic response coef. (Cs) = Sosl/R = 0.300 need not exceed Cs = Sdi I /RT = 1.156 but not less than Cs = 0.5'S11/R = 0.075 USE Cs = 0.300 Design Base Shear V = 0.300W Model & Seismic Response Analysis - Permitted (see code for procedure) ALLOWABLE STORY DRIFT Structure Type: All other structures Allowable story drift Da = 0.020hsx where hsx is the story height below level x Acumen Engineering Design JOB TITLE 24' x 40' Commercial Modular 11624 North 151st Lane Pad/Pier/Anchor Design Surprise, Arizona 85379 JOB NO. SHEET NO. 6 801-571-9877 CALCULATED BY DATE CHECKED BY DATE SEISMIC LOAD EFFECTS FOR ANCHOR DESIGN (Simplified Design Procedure - ASCE 7-16) Input: Design Base Shear: (V) Calculations: Maximum Seismic Load Effect: (no gravity loads on anchors) Seismic Load Effect: (no gravity loads on anchors) 0.300 W = Qo(Qe) + 0 (Eq. 12.4-7) Overstrrength Factor: (0o) = 2.0 Earthquake Load Due to Base Shear: (Qe) = V Em = 0.600 W E = p(Qe) + 0 (Eq. 12.4-3) Redundancy Factor: (p) = 1.3 Earthquake Load Due to Base Shear: (Qe) = V E= 0.390 W Governing Earthquake Load: E = 0.600 W Allowable Stress Design: 0.7E (Section 2.4.5) Earthquake Load Used in Lateral Design: 0.420 W 7 Single Pad Configuration Calculations: Bearing Pad Capacity Calculations: Species: P.T DF-L #2 Assumed Bearing Capacity: (Bc) , 1500 psf Cross Sectional Area: (AP) 16.9 in2 Section Modulus: (Sx,p) 4.2 in3 Pad Specifications (Tp) x (Wp) x (LP) Nominal: 2 x 12 x 24 Assume Load on Pad is Centered Actual: 1.5 x 11.25 x 24 Load Width on Pad: (LW) 10 in Pad Cantilever: (Cp) • 7 in Uniform Distributed Load: W = (Bp / 144) x Wp Maximum Moment: Mmax = 0.5 x W x Cp2 Allowable Bending Stess: fb = Mmax / Sx, p Maximum Shear: Vmax = W x Cp Allowable Shear Stess: fv = 1.5 x (Vmax / AP) Fe = 900 x 0.8 x 1.2 x 0.8 = 691 psi (Cm) (Cfu) (G) F,; = 180 x 0.8 x 0.8 = 115 psi (Cm) (Ci) 117 pli 2871 lbs 681 psi < Fe => OK in Bending 820 lbs 72.9 psi < F„' _> OK in Shear => Capacity of Each Pad is: 3000 lbs 8 PAD/PIER SPACING Input Data: Roof Live Load: (RI) Roof Dead Load: (Rd) Exterior Wall Dead Load: (Wd) Floor Live Load: (FI) Floor Partition Load: (Fp) Floor Dead Load: (Fd) Module Width: (W) Sidewall Height: (H) Pad Capacity: (P) Pier Capacity: (P) 20 psf 6 psf 6 psf 50 psf 15 psf 7 psf 11.83 feet 8.5 feet 3000 lbs 3000 lbs Calculations: Weight of Exterior Wall: We = (Wd x H) 51 plf Live Load Acting on Outside Chassis Main Rails: Wlo = (RI+FI) x (W/2) 414.1 plf Dead Load Acting on Outside Chassis Main Rails: Wdo = ((Rd+Fp+Fd)(W/2)) + We 216.6 plf Total Load Acting on Outside Chassis Main Rails: Wo = WI + Wd 630.7 plf Maximum Spacing of Piers on Outside Main.Rails: S = P/Wo 4.76 feet Live Load Acting on Inside Chassis Main Rails: Wli = Fl x (W/2) 295.8 plf Dead Load Acting on Inside Chassis Main Rails: Wdi = (Fp+Fd) x (W/2) 130.1 plf Total Load Acting on Inside Chassis Main Rails: Wi = Wli + Wdi 425.9 plf Maximum Spacing of Piers on Inside Main Rails: S = P/Wi 7.04 feet Column Support (END COLUMN): Input Data Tributary Width: (Tw) End Column Tributary Length: (Te) Live Load: (LLr) Dead Load: (DLr) Calculations: Pad Capacity: (Cpad) Pier Capacity: (Cpier) Roof Tributary Area: Ar = 0.5 x Tw x Te Ar > 200 Live Load (LLr) is Reducible: 24 - 0.02Ar 11.83 ft 20 ft 20 psf 6 psf 3000 lbs 3000 lbs 237 sq. ft. 19-psf Column Load: (Pe) = (LLr + DLr) x Ar 5978 lbs Qty of Pads: Npads = Pe / Cpad 1.99 Qty of Piers: Npiers = Pe / Cpier 1.99 Use (2) 3000 LB. ASYMETRIC PIERS (ONE EACH SIDE OF MODULE LINE). EACH , PIER MUST HAVE (1) 2x12x24 BEARING PAD 10 ANCHOR DESIGN Input Data: Design Wind Pressure: (P) Seismic Load Factor: (SI) Roof Dead Load: (Rd) Floor Dead Load: (Fd) Exterior Wall Dead Load: (Wd) Roof Live Load used in Seismic Calculation: (RI) Partition / Fixture Load used in Seismic Calculation: (Pd) Floor Live Load used in Seismic Calculations: (FI) Building Length: (L) Building Depth: (D) Building Area: (A) Exterior Wall Height: (H) Roof Depth: (R) Floor Depth: (F) Skirting / Foundation Height: (S) Miscellaneous Loads: (MI) Calculations: Base Shear Due to Wind: Vw=Px(R+F+H+S/2) Base Shear Due to Seismic: Vs = (SI)(((A)(Rd+Fd+RI+Pd+FI))+ ((L+D)x2xHxWd))+MI) Governing Transverse Base Shear:(V) Anchor Capacity: Lateral Load Resistance of Anchor/Strap Assembly: VL Ground Anchor Quantity: In Each Transverse Direction: Nt = VNL In Each Longitudinal Direction: Nt = VINL Total Quantity of Anchors Required: 16 psf 0.42 W 6 psf 7 psf 6 psf 0 psf 5 psf 0 psf 40 feet 23.67 feet 947 sq. ft. 8.5 feet 2.5 feet 0.67 feet 2.33 feet 1000 lbs Transverse Load: Longitudinal Load: x L 8214 lbs x D 4860 lbs 10304 lbs 10304 lbs 2962 lbs 3.48 say 4 3.48 say 4 16 Anchors 10304 lbs 10304 lbs BEST AVAILABLE IMAGE ABESCO ENGINEERED COMBINATION TIE -DOWNS . I MANUFACTURED HOME TIE -DOWN CALCULATIONS ANDSCHEDULES FOR E /Dips; SINGLE/ DOUBLE / TRIPLE AIDES • 'DESIGN &GENERAL NOTES PSF (70 MM;EXPOSPRE;441) CAC T-26 and COMPLIES WITH tHEZOI CBC. f•• . — Vint 110 'MPi.1 EXP °CI SOIL BE I 15� . • ctiii5DwN STRAP WORKING OAP *SEISMIC ZONE . 4.CAC T-25 AND 2(i3'pec;. ot.LEFitaltaciiksite, anal_ Tie DOWN -STRAPS to BE 1/4" WIDE XO.029Th1CKNE$ ZINO,PLAItD AND. MEET AVM D49510 ''EARTIOUGERS 2962 #. (TESTED TO 47600 MIN) CROSS DRIVES 2962 # (TESTED TO 47.600 MIN) ''CONCRETE SLAB ANCHORS .139Q * (CALCULATED) GENERAL NOTES: • •-1: THE CHARTS SHOWN HERON ARE FORTHE REQUIRED *NUMBER OF DOWNS ON THE SIDES OF THE -MANUFACTURED HOME. 2. TIE DOWNS ARE AT EACH CHASSIS BEAM, EACH END. OF EACH TRANSPORTABLE SECTION OF THE MANUFACTURED HOME AND CAN SE ANY OF THE TYPES SHOWN:HEREIN., 3. COMBINATIONS OF THE DIFFERENT TYPES,17,F TIE DOWNS CAN BE USED.' 4. IN THE EVENT AN EARTH AUGER CANNOT BE INSTALLED DUE TO AN OBSTRUCTION, USE Of CROSS DRIVE: ANCHORS IS PERMITTED, PROVIDED (2) owns:DRIVES ARE INSTALLED FOR EACH EARTH AUGER THAT CANNOTSE INSTALLED. 1. FOR ALL rig DOWN INSTALLATIONS, THE MFGD HOME CHASSIS MEMBERS AR#'StiOlfiN ASla BEAMS, FOR iLLUSTRATIai PURPOSES ONLY CHAttisii0.416 CAN ALSO-ii&dwii44 t ENO TIE DOWNS CAN BE LOCATED WITHIN 24":,Of EITHER SIDE OF CHASSIS BEAM MIS AtMOVAI. cHAiiis 8E44 01 • (9NE,END 'NE-00VO4 MANDATORY ATEACH END OF 'V BEAN) , . 7. THE SIZES, TYPES;LENOTHS, ECT. OF MATERIAL SHOWN HEREIN ARE MINIMUM, LARGER) LONGER, HEAVIERMATERIALS SUPPLIED BYABESCO MAY BE USED AT THE SAME SPACING tLOCATION SHOWN, 8. PARTS AR— E STAMPED ABESCO 9. THIS TIEDOWN SYSTEM CAN BE USED WITH 10' WIDE MANUFACTURED HOME SECTIONS WITH 100. CHASSIS CENTERS PROVIDED THE HEIGHT FROM GRADE Td trIE BOTTOM OF CHASSIS BEAM DOES NOT EXCEED 19" 10, TIE DOWN sTiwAIPa THE LONGppINALPRTRANSVERSE DIRECTION CAN BE BOLTED TO THE HITCH ATTACHMENT PLATE THAT IS WELDED TO THE CHASSIS BEAM. A.01 ENGINEER APPROVAL. STATE APPROVAL •4 _,.•,, , , . . ,,,, if ' 4 . 0 t. a‘ • 1 Ott . t ' 111 . 1.44 i I/ Al fl • (it I* * • Al 1 ki O ' To Tieoovitr SYSTEM mware REOUIREMENTS; • OF 8ECTION13$13, SUBSECTION (a) , ‘ , . . ENGINEERED TIEDOWN SYSTEM • APPROVED • -4:' ".. . ., . ‘ Approvo &dna' autitortre or approve ani omission or 4eviattOo too requitementS of ippticabto State taws and • textaions. .. State of COlifOffila Departintiiit of i-kr and Commoritype4oPment DIVIS1 ' DES AND S DARDS , By ,,. Date i—fillil .. nattge) r SPAN , it."t5 I 0 ›, C.-. . - ' 1.10 Pfeil Approvat Explrea • - • PACIFIC CONSLILTINO ENGINEERS 21.50 SELL AVE, SUITE :146 SACRAMENTO, CALIFORNIA45888 PH (.916) 684-8028 0. 4 ABESCO 6851. FLORIN-PERKINS ROAD,. SACRAMENTO, -CALIFORNIA 95828 PH: 8004834831 • 603 24" T.D.A. 40. 48w T.D.A. •END .11E GOWNS- EEC. CHART SINGLE `WIDE ABESCO TIE -DOWNS; (AMMO MM— TWO N HEAD.* OA M 00Y.10 , 607 GROSS' E ANCHOR ROD "SIZES 91s"x30"STEEL ALTERNATE:, 1i"x3O"` GALV:. PIPE OR. TOO" BLACK PIPE 1443 806 STEEL, .. STRAP w/ BUC S08 SPTJT L`T do 'NUT 1604. „CONCRETE LAR'ANCHOR. W/' %"xis" EXP. ANCHOR #407 LOCK TOP �I406 PIER. BOLT —ON TOP A.02 1616' STABILIZER PLATE ®814 STEEL STRAP w/.HOLE f8t5 WET -ANCHOR HEAD whi"x8'' FOUNDATION BOLT TIE DOWN ,LOCATIONS TIE 00VHS, SEE CHART DOUBLE 'WIDE tn0 •T DOwr+$. SEE CHART 'TRIPLE WIDE EARTH AUGERS CROSS DRIVE ANCHORS _ CONCRETE SLAB ANCHORS, M OFE acts b4' 72' M 36' 54' 7r " LENGTH E R 34. 42' 50' 59' 88' MAX.E 0. O SiDE 2 3 4 MAX. ND,:°OP SIDE `TIE ROANS 2 3' 4 MAX. NO, QFSIDE TIE DOWNS' 4 .6 6 7 6 NOTE: 'SIDE' TIE-DOWNS:.MUST BE WITHIN 24" OF THE END .OF THE CHASSIS BEAM: END 'TIE-DOWNS:.CAN BE LOCATED WITHIN. 24" OF EITHER ..SIDE OF ,CHASSIS. BEAM ONE TIE —DOWN IS -MANDATORY AT ,EACH' END OF '"t„BEAM. (SEE PAGE #1 GENERkL NOTE #5),. IF SIDE WALL LIE -GOWN GROUND ANCHOR LOCATION IS SUCH THAT THE ANGLE BETWEEN YHE GROUND AND; STRAP EXCEEDS 60', CONNECT THE TIE STRAP TO THE. INSIDE CHASSIS BEAM' ON DOUBLE AND, TRIPLE WIPES AND THE OPPOSITE :CHASSIS 8EAMI ON SINGLE WIRES: CV W d a 0 • CROSS DRIVE TIE DOWN END TIE -DOWN 1401 LOC)OPOR .- 4406, PO 8OLTON TOP • - STRAP INSTALLATION INSTRUCTIONS ;SIDE TI DOWN 606; STEEL. #00,8 OUT SOL,T ,d; NOT #4f6 $.1X41.1) PLAtt 4GROUND' LiN 607 CROSS DRIVE ANCHOR TAIL "A" (TYPICAL ,CROSS DRIVE' WITH ,STABIU2ER PLATO INsTA4., CROSS pRive,AN0p-Rs, INTO s.424. AS SHOWN. 2. MACH STRAPS T CHASSIS 'BEAM 'IN WOO SHOWN. INSERT STRAP THROUGH SPLIT BOLT, GUT OFF EXCESS STRAP AND THEN' TIGHTEN BOLT' UNTIL STRAP IS SNUG. CONTRACTORS WARNING' CHECK :FIRST FOR UNDERGROUND UTILITIES. CROSS. DRIVE ANCHORS ARE .osto WHERE HARD ,OR AccKy, SOIL pcCOS", IF THE GROUND SURFACE IS pigR. THAN RoeK 'DR MINIMUM ZN ASPHALT, INSTALL #616 STABILIZER PLATE: (STABILIZER PLATES MAY BE PREWELOED TO, #607 CROSS DRIVE MCHORI :INSTAii 1 ex12",,x1r CONCRETE MACK; NOTE1 IF A CROSS DRIVE IS USED WHERE AN .AucER, COULD E us1;0 LOAMY rot SOIL), THEN TWO CROSS ;RIVES MUST BE INS.T4I-EP PROPERLY IN PLACE OF THE ONE TIE -DOWN . BOTH CROSS DRIVES MUST BE STABILIZED AS SHOWN IN :DETAIL ne. SEE PAGE #1,, naNtutAL NOTE 'THISPLAN'Mkt:BE OSSOFORNAOUFAcItigp:HOMEs;FLAggs IN FEMA,FLOOD HAZARD, 'ZONES A, AE & AH, PROVIDED THE,GROOND'ANCHORSARETHE #603410I-T,D.A. EARTH •AUGERS t UNDER FLOOR VENTS AT THE PERIMETER SKIRTING SHALL septAcEp.wiTH, THE 'BOTTOM OF THE VENT MAKIVABOVE.THE uNOEA FLOOR GROUNIY SURFACE CONCKETE TIE DOWN - INSTALLATION INSTRUCTIONS OE TIE-0004 END °T1Ei-,00* ,;$07. LOCK 10.7 00 , #406 PIER- BOLT,,ON 'TOP 6,14,.. St. NOSS '13 •••-•-'12 1st" se° 606 S 'TEEL • 804- 004.04"Tt SLAT 6i5 WET; ANCOR I= 4604 DRY I. CONCRETE. MUST BE .A; MINIMUM OF 3,6!,1 THICK AND It0015 GONDITION. 2, MINiMum:;$148 AREA OF EACH ANgHofi 28' SQUARE FEET, DRILL. PROpER SIZE HP4' IN LAR, A MINIMUM OF 12FROM ANY EDGE. #65, WE 3'. A.03 PLACE CONCRETE ANCHOR INTO WET CONCRETE. ,2. ALLOW. CONCRETE TO PROPERLY DRY. CHASSIS.CONNECTI' ON ATTACH' STRAPS TO CHASSIS BEAM IN MANNER SHOWN, . INSERT STRAP THROUGH spar soLf. cur OFF EXCESS' STRAP AND THEN TIGHTEN BOLT UNTIL STRAP IS .SNUG. cL 0 '7453FAM CI4ASSIS SEE " SEAM OFIAStIS, NOTE #Si, 'WET 1 FOR 'TIE -DOWN ,INFORMATiON ENDTIE=DOWN *407 1,110cK 10 OR' #408' PIER' BOLTAON TOP o'-1 SEE DETAIL l!A" . !.01404: DRILL 3(.HOLE AT MID KEIOHT- 'OF BEAM, :1061.64 141AO7 BOLT • -7); BEAM C.14tit. SEE, 17 BEAM tO4A.WIS: NOTEi IS -SHEET' I FOR. IJE.:4P,OWN1N.FPWATP.0 TIE IDCWN. •SiOE TIE! Qviini 000'STEEL „ POT OF OK ' • 10.5.174(A7. *30;Z8011 p BEAM CHASSIS SEE T • 8 IS I NOTE: lit ,SHEEt ` FOR TIE-,po iNFqNNATI9N. ALL GROUND ANCHOR INTO GROUND; LEAVING A.04 OLP' BOLT &NLtr GROUND LINE • STILiZER PLATE NOTE: voricA, oft AroiAlt Q.PT19144 SEE DETAIL 'A" (TYPKAL) INSTALLATiON INSTRuCTIONS: 1:,,INstAu:Anction INTasca APPLYINq CO WANT DOWNWAito ETOMINIMW. SOX DIPUREAPCgi 14NTIX HMIS WITH .144W. PLATE:Am:Hats *ow) NigrAkup egov,r FROST UNE. ATTAE14'01AFATOIASSIS BEAM IN MANNER SHOWN. 1 'INSERT:01AP tHROt40 spUT BOLT,r0TM OMESS.SYRAP AND /MEN ‘TIGOTE)eigl:TUM11.,STRAP IS NUG. CONTRACTOR§ WARNING: Okk-FaistlFciR'UNDERGROUND uTurtzs: ::PLAcEsTABluIERNAIE V.-NoirTo•sHAFT BErwEefr* •• WHORANOtKASSIS BEAK AND DRIve:INT0 GROUND FINISH lyRNINGNictial THE GRAUND 0.4 ANOKA Hap 10401, Virni STABILIZER Alp PROVIDES PROTECTION AGAINST. LATERAL MOVBIBITI 1! 4: _ CO. NTRA' CTORS VERIFICA- TION - :LcERTIFy:THAT t HAvg40,57:41E:o. THE.ApescciAN400q,VgEtpi Wigi? IffEls7 HAvpobtNO ri;obotAnoNs. to THE ANCHORING SYSTEM OR to,ttle BUILDING COMPANY NAME DATE:.-. fl.W 1-09 SIGNATURE: JTONITN$TRUCTIONS: CTURE, CON -TRACTORS LTC. *w. 44t 'd? BSK Associates Engineerboraturies Ph. 951-674-4011 • Fax 951-674-5720 www.sedcopier.com 33320 Mission Trail • Wildomar, CA 92595 567 West Shaw Avenue. Suite 8 Fresno. CA 93704 (550) 497 2880 (559) 497.2886 fox Test Report No. 11011-4K & 3K 1) 3/4" X11 GA. SAE Flatwasher ASTM A36 2) 1" O.D. x 13 GA.x1" Roll Tube ASTM A36 3) 1"x1" Formed Angle Legs ASTM A36 4) 1 1/4" x 13 GA. Flat Base ASTM A36 5) Weld Width 1/4" ER 705-X 6) Embossed Label SEDCO List #1976-1 BSK # 11011-4K & 3K 14" to 16" 4000 lbs 18" to 30" 3000 lbs Listing #1976-1 PPR VAL PACIFIC CONSULTING ENGINEERS 2150 Bell Ave. Suite 145 • Sacramento, CA 95838 PH. (916) 564-6028 www.sedcopier.com • 951.674.4011 A.05 A B C D Part# Height Max t Width Guage 14" 17" 11 1/4" 12 4014 16" 19" 11 1/4" 12 4016 18" 21" 11 1/4" 12 4018 20" 23" 11 1/4" 11 4020 22" 25" 11 1/4" 11 4022 24" 27" 11 1/4" 11 4024 26" 29" 11 1/4" 11 4026 28" 31" 111/4 .11 4028 30" 33" 11 1/4" 11 4030 STATE APPROVAL Mubit.l;l1C"t''II' cl A.CCI'SS('.R's' Si R'.'CI I RP BUILDING COMPONENT AND SAFE t'1' C OD1.. DIVISION 13, PART2 ,l)'PItovE11 Approval does n!a ..othwize or approve any omission or deviation from requirements of applicable State laws and regulations. STATE OF CALIFORNIA DEPARTMENT OF MOUSING AND COMMUNITY DEVELOPMENT DIVISION 01 CODES AND STANDARDS By OL/ Date .3/4 HP NO. (siinat&J4) This Approval Ex