Loading...
HomeMy WebLinkAbout03_SweatHouz Minor Use Permit_PA2024-0079CITY OF NEWPORT BEACH ZONING ADMINISTRATOR STAFF REPORT November 14, 2024 Agenda Item No. 3 SUBJECT: SweatHouz Wellness Studio (PA2024-0079)  Minor Use Permit SITE LOCATION: 2210 Newport Boulevard, Suite 104 APPLICANT: Chandler Clark OWNER: Peninsula Village, LLC PLANNER: Laura Rodriguez, Planning Technician 949-644-3216 PROJECT SUMMARY A request for a minor use permit for the approval of a wellness studio, which is classified as a “Personal Services, Restricted” land use. The studio is proposed to operate within a 1,265 square-foot tenant space, and offers an infrared sauna, a cold plunge, and other wellness services. The studio has proposed hours of operation from 7:00 a.m. to 8:00 p.m., Monday through Friday, and 8:00 a.m. to 5:00 p.m. on Saturday and Sunday. RECOMMENDATION 1) Conduct a public hearing; 2) Find this project exempt from the California Environmental Quality Act (CEQA) pursuant to Section 15301 under Class 1 (Existing Facilities) of the CEQA Guidelines, California Code of Regulations, Title 14, Division 6, Chapter 3, because it has no potential to have a significant effect on the environment; and 3) Adopt Draft Zoning Administrator Resolution No. _ approving the Minor Use Permit filed as PA2024-0079 (Attachment No. ZA 1). DISCUSSION • The proposed wellness therapy studio is located within the Peninsula Village mix use development. The Project’s tenant space is located on the first floor alongside other existing commercial uses such as retail and a health and fitness facility. The project faces Newport Boulevard and is directly across several existing commercial uses on Balboa Boulevard, and between 21st and 26th Street, which are also identified as Mixed-Use zoning districts. Those properties are currently operating as restaurants and retail stores. 1 • The project site is in the Mixed-Use Water (MU-W2) Zoning District and Mixed-Use Water 2 (MU-W2) General Plan Land Use. The MU-W2 land use category is intended to provide commercial development on or near the bay in a manner that encourages the continuation of coastal-dependent and coastal-related uses in accordance with the Recreational and Marine Commercial (CM) designation, as well as allow for the integrated residential development. The MU-W2 land use category specifically applies to waterfront locations where marine-related uses may be intermixed with buildings that provide residential on the upper floors. The Project is located within the Peninsula Village mixed-use development on the waterfront, which consists of commercial uses on the first floor and residential units above. • The proposed wellness studio is classified as a Personal Services, Restricted land use and is permitted with the approval of a minor use permit. A minor use permit is required as the restricted uses may tend to have a blighting and/or deteriorating effect upon surrounding areas and may need to be dispersed from other similar uses to minimize adverse impacts. • The previous use in the existing tenant space operated as a retail store. No additional square footage is proposed as part of this project. The proposed wellness studio does not involve an intensification of use as it requires parking at a rate of 1 parking space per 250 square feet, which is the same parking requirement as the previous use. Therefore, since there is no intensification of use associated with the project, a coastal development permit is not required. • The wellness studio will operate daily, from 7:00 a.m. to 8:00 p.m., Monday through Friday, and 8:00 a.m. to 5:00 p.m. on Saturday and Sunday. The project does not propose late hours (past 11:00 p.m.) which will minimize potential disturbance to residences nearby the project site. ENVIRONMENTAL REVIEW This project is exempt from the California Environmental Quality Act (CEQA) pursuant to Section 15301 under Class 1 (Existing Facilities) of the CEQA Guidelines, California Code of Regulations, Title 14, Division 6, Chapter 3 because it has no potential to have a significant effect on the environment. This exemption authorizes minor alterations to existing structures involving negligible or no expansion of use. The proposed project does not involve construction changes to the existing tenant space. PUBLIC NOTICE Notice of this hearing was published in the Daily Pilot, mailed to all owners of property within 300 feet of the boundaries of the site (excluding intervening rights-of-way and waterways) including the applicant, and posted on the subject property at least 10 days before the scheduled meeting, consistent with the provisions of the Municipal Code. Additionally, the item appeared on the agenda for this meeting, which was posted at City Hall and on the city website. 2 APPEAL PERIOD: An appeal or call for review may be filed with the Director of Community Development within 14 days following the date of action. For additional information on filing an appeal, contact the Planning Division at 949-644-3200. Prepared by: ____________________________ Laura Rodriguez, Planning Technician DL/lr ATTACHMENTS ZA 1 Draft Resolution ZA 2 Vicinity Map ZA 3 Project Plans 3 Attachment No. ZA 1 Draft Resolution 4 RESOLUTION NO. ZA2024-### A RESOLUTION OF THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH, CALIFORNIA, APPROVING A MINOR USE PERMIT FOR A WELLNESS STUDIO (PERSONAL SERVICES, RESTRICTED) LOCATED AT 2210 NEWPORT BOULEVARD, SUITE 104 (PA2024-0079) THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH HEREBY FINDS AS FOLLOWS: SECTION 1. STATEMENT OF FACTS. 1. An application was filed by Chandler Clark, on behalf of Peninsula Village LLC (Applicant), concerning property located at 2210 Newport Boulevard, Suite 104, and legally described as Lot 1 of Tract 16594 (Property) requesting approval of a minor use permit. 2. The Applicant proposes a minor use permit to operate a wellness studio, which is classified as a “Personal Services, Restricted” land use. The studio is proposed to operate within a 1,265- square-foot tenant space and offers an infrared sauna, a cold plunge, and other wellness services. The studio has proposed hours of operation from 7:00 a.m. to 8:00 p.m., Monday through Friday, and 8:00 a.m. to 5:00 p.m. on Saturday and Sunday (Project). 3. The Property is designated Mixed-Use Water 2 (MU-W2) by the General Plan Land Use Element and is located within the Mixed-Use Water (MU-W2) Zoning District. 4. The Property is located within the coastal zone. The Coastal Land Use Plan category is Mixed-Use Water Related (MU-W) and it is located within the Mixed-Use Water (MU-W2) Coastal Zoning District. 5. A coastal development permit is not required since the Project does not involve an intensification of use as the required off-street parking rate does not change from the previous use. 6. A public hearing was held on November 14, 2024 online via Zoom. A notice of the time, place, and purpose of the hearing was given in accordance with the Newport Beach Municipal Code. Evidence, both written and oral, was presented to and considered by, the Zoning Administrator at this hearing. SECTION 2. CALIFORNIA ENVIRONMENTAL QUALITY ACT DETERMINATION. 1. This Project is exempt from the California Environmental Quality Act (CEQA) pursuant to Section 15301 under Class 1 (Existing Facilities) of the CEQA Guidelines, California Code of Regulations, Title 14, Division 6, Chapter 3 because it has no potential to have a significant effect on the environment. 5 Zoning Administrator Resolution No. ZA2024-### Page 2 of 8 2. This exemption authorizes minor alterations to existing structures involving negligible or no expansion of use. The Project includes the operation of a wellness studio within an existing tenant space. No additional square footage is proposed for the Project. SECTION 3. REQUIRED FINDINGS. In accordance with Section 20.52.020 (F) (Conditional Use Permits and Minor Use Permits – Findings and Decision) of the Newport Beach Municipal Code, the following findings and facts in support of such findings are set forth: Finding: A. The use is consistent with the General Plan and any applicable specific plan. Facts in Support of Finding: 1. The General Plan Land Use category for this property is Mixed-Use Water 2 (MU-W2), which is intended to provide commercial development on or near the bay in a manner that encourages the continuation of coastal-dependent and coastal-related uses in accordance with the Recreational and Marine Commercial (CM) designation, as well as allow for the integrated residential development. The MU-W2 land use category specifically applies to waterfront locations where marine-related uses may be intermixed with buildings that provide residential on the upper floors. The Project is located within the Peninsula Village mixed-use development on the waterfront, which consists of commercial uses on the first floor and residential units above. 2. The Property is not part of a specific plan area. Finding: B. The use is allowed within the applicable zoning district and complies with all other applicable provisions of this Zoning Code and the Municipal Code. Fact in Support of Finding: 1. The Property is located within the MU-W2 zoning district, which allows a Personal Services, Restricted land use with the approval of a minor use permit. A minor use permit is required as the restricted uses may tend to have a blighting and/or deteriorating effect upon surrounding areas and may need to be dispersed from other similar uses to minimize adverse impacts. 2. As previously noted, the Property is located within Peninsula Village, which is an existing mixed-use development that allows for commercial uses on the first floor. The surrounding commercial uses from the Property include retail, food service, and other similar commercial uses not classified as Personal Services, Restricted. Therefore, the use is dispersed from similar uses that may create adverse impacts. 6 Zoning Administrator Resolution No. ZA2024-### Page 3 of 8 3. The previous use in the existing tenant space operated as a retail store. The Project does not involve an intensification of use as it requires off-street parking at a rate of 1 space per 250 square feet of gross floor area, which is the same parking requirement as the previous use. In addition, residential parking at the Property is provided through the existing parking garage. Since there is no intensification of use associated with the Project, a coastal development permit is not required. Finding: C. The design, location, size, and operating characteristics of the use are compatible with the allowed uses in the vicinity. Facts in Support of Finding: 1. The proposed wellness studio is located within Peninsula Village, which is an existing mixed-use development that is compatible with the surrounding uses at the project site and in the surrounding area. The Project’s tenant space is located on the first floor alongside other existing commercial uses such as retail and a health and fitness facility. In addition, the Property faces Newport Boulevard between 21st and 26th Street and is directly across several existing commercial uses on Balboa Boulevard, which are also identified as mixed-use zoning districts. Those properties are currently operating as restaurants and retail stores. 2. The wellness studio will operate from 7:00 a.m. to 8:00 p.m., Monday through Friday, and 8:00 a.m. to 5:00 p.m. on Saturday and Sunday. The Project does not propose late hours (past 11:00 p.m.) which will minimize any potential disturbance to residences nearby the Property. Finding: D. The site is physically suitable in terms of design, location, shape, size, operating characteristics, and the provision of public and emergency vehicle (e.g., fire and medical) access, and public services and utilities. Facts in Support of Finding 1. The Property is located on Newport Boulevard between 21st and 26th Street, with heavier vehicular traffic and pedestrian activity in the vicinity as the public beach is approximately 645 feet west of the Property. Additionally, the Property is adjacent to the Newport Harbor. There are also multiple public parking spaces along Newport Boulevard and across the street on West Balboa Boulevard which can serve as supplemental parking for patrons visiting the Property. 2. The Project will occupy an existing tenant space in an existing commercial building serviced by all necessary utilities. No additional square footage is proposed as part of this Project. In addition, the design, location, shape, size, and operating characteristics 7 Zoning Administrator Resolution No. ZA2024-### Page 4 of 8 of the use are compatible with the existing commercial related services. The Project offers wellness services that include an infrared sauna and a cold plunge. 3. The Fire Department has reviewed the Project and provided conditions of approval which are outlined in the attached “Exhibit A”. Finding: E. Operation of the use at the location proposed would not be detrimental to the harmonious and orderly growth of the City, nor endanger, jeopardize, or otherwise constitute a hazard to the public convenience, health, interest, safety, or general welfare of persons residing or working in the neighborhood of the proposed use. Facts in Support of Finding: 1. Per Condition of Approval No. 5, the Project shall operate during the hours that have been stated in this Resolution which will minimize disturbances from neighboring residences and ensure compliance with noise from the project site. 2. The Peninsula Village’s mixed-use development under PA2001-210 extensively reviewed parking, vehicular and pedestrian access, and commercial uses offered at the Property. Given that the Project’s proposed use will operate in an existing tenant space of Peninsula Village, it is not anticipated that the use will be detrimental to the harmonious growth of the City or constitute as a public inconvenience to the surrounding neighborhood. 3. Fact 3 in support of Finding B is hereby incorporated for reference. SECTION 4. DECISION. NOW, THEREFORE, BE IT RESOLVED: 1. The Zoning Administrator of the City of Newport Beach hereby finds this project is categorically exempt from the California Environmental Quality Act pursuant to Section 15301 under Class 1 (Existing Facilities) of the CEQA Guidelines, California Code of Regulations, Title 14, Division 6, Chapter 3 because it has no potential to have a significant effect on the environment. 2. The Zoning Administrator of the City of Newport Beach hereby approves Minor Use Permit No. PA2024-0079 subject to the conditions outlined in Exhibit “A”, which is attached hereto and incorporated by reference. 3. This action shall become final and effective 14 days following the date this Resolution was adopted unless within such time an appeal or a call for review is filed with the Community Development Director by the provisions of Title 20 (Planning and Zoning), of the Newport Beach Municipal Code. 8 Zoning Administrator Resolution No. ZA2024-### Page 5 of 8 PASSED, APPROVED, AND ADOPTED THIS 14th DAY OF NOVEMBER 2024. ____________________________________ Benjamin Zdeba, AICP, Zoning Administrator 9 Zoning Administrator Resolution No. ZA2024-### Page 6 of 8 EXHIBIT “A” CONDITIONS OF APPROVAL (Project-specific conditions are in italics) Planning Division 1. The development shall be in substantial conformance with the approved site plan, floor plans, and building elevations stamped and dated with the date of this approval (except as modified by applicable conditions of approval). 2. The project is subject to all applicable City ordinances, policies, and standards unless specifically waived or modified by the conditions of approval. 3. The applicant shall comply with all federal, state, and local laws. A material violation of any of those laws in connection with the use may cause the revocation of this Minor Use Permit. 4. This minor use permit, as part of PA2024-0079, shall expire unless exercised within 24 months from the date of approval as specified in Section 20.91.050 of the Newport Beach Municipal Code unless an extension is otherwise granted. 5. The project shall operate from 7:00 a.m. to 8:00 p.m., Monday through Friday, and 8:00 a.m. to 5:00 p.m. on Saturday and Sunday. 6. This Minor Use Permit may be modified or revoked by the Zoning Administrator if determined that the proposed uses or conditions under which it is being operated or maintained are detrimental to the public health, welfare, or materially injurious to property or improvements in the vicinity or if the property is operated or maintained to constitute a public nuisance. 7. Any change in operational characteristics, expansion in the area, or other modification to the approved plans, shall require subsequent review and approval of the Planning Division. Depending on the nature of the request, an amendment to this Minor Use Permit or the processing of a new Use Permit, may be required. 8. If construction or alterations are proposed that would require a building permit, a copy of the Resolution, including Exhibit “A”’s Conditions of Approval, shall be incorporated into the Building Division and field sets of plans prior to issuance of the building permits. 9. The applicant shall pay any unpaid administrative costs associated with the processing of this application to the Planning Division. 10. All noise generated by the proposed use shall comply with the provisions of Chapter 10.26 (Community Noise Control) and other applicable noise control requirements of the Newport Beach Municipal Code. 10 Zoning Administrator Resolution No. ZA2024-### Page 7 of 8 11. Should the property be sold or otherwise come under different ownership, any future owners or assignees shall be notified of the conditions of this approval by either the current business owner, property owner or leasing agent. 12. Construction activities shall comply with Section 10.28.040 (Construction Activity – Noise Regulations) of the Newport Beach Municipal Code, which restricts hours of noise-generating construction activities that produce noise to between the hours of 7:00 a.m. and 6:30 p.m., Monday through Friday. Noise-generating construction activities are not allowed on Saturdays, Sundays, or Holidays. 13. No outside paging system shall be utilized in conjunction with this establishment. 14. Deliveries and refuse collection for the facility shall be prohibited between the hours of 10:00 p.m. and 7:00 a.m. on weekdays and Saturdays and between the hours of 10:00 p.m. and 9:00 a.m. on Sundays and Federal holidays unless otherwise approved by the Director of Community Development and may require an amendment to this Use Permit. 15. All trash shall be stored within the building or within dumpsters stored in the trash enclosure (three walls and a self-latching gate) or otherwise screened from view of neighboring properties, except when placed for pick-up by refuse collection agencies. The trash enclosure shall have a decorative solid roof for aesthetic and screening purposes. 16. Trash receptacles for patrons shall be conveniently located both inside and outside of the establishment, however, not located on or within any public property or right-of-way. 17. The exterior of the business shall be always maintained free of litter and graffiti. The owner or operator shall provide for daily removal of trash, litter debris, and graffiti from the premises and on all abutting sidewalks within 20 feet of the premises. 18. The applicant shall ensure that the trash dumpsters and/or receptacles are maintained to control odors. This may include the provision of either fully self-contained dumpsters or periodic steam cleaning of the dumpsters if deemed necessary by the Planning Division. Cleaning and maintenance of trash dumpsters shall be done in compliance with the provisions of Title 14, including all future amendments (including Water Quality related requirements). 19. Storage outside of the building in the front or at the rear of the property shall be prohibited, except for the required trash container enclosure. 20. A Special Events Permit is required for any event or promotional activity outside the normal operating characteristics of the approved use, as conditioned, or that would attract large crowds, involve the sale of alcoholic beverages, include any form of on-site media broadcast, or any other activities as specified in the Newport Beach Municipal Code to require such permits. 11 Zoning Administrator Resolution No. ZA2024-### Page 8 of 8 21. To the fullest extent permitted by law, the applicant shall indemnify, defend and hold harmless the City, its City Council, its boards and commissions, officials, officers, employees, and agents from and against any claims, demands, obligations, damages, actions, causes of action, suits, losses, judgments, fines, penalties, liabilities, costs, and expenses (including without limitation, attorney’s fees, disbursements, and court costs) of every kind and nature whatsoever which may arise from or in any manner relate (directly or indirectly) to City’s approval of SweatHouz Wellness Studio including, but not limited to, Minor Use Permit No. PA2024-0079. This indemnification shall include, but not be limited to, damages awarded against the City, if any, costs of suit, attorney’s fees, and other expenses incurred in connection with such claim, action, causes of action, suit, or proceeding whether incurred by the applicant, City, and/or the parties initiating or bringing the such proceeding. The applicant shall indemnify the City for all the City's costs, attorneys' fees, and damages that which City incurs in enforcing the indemnification provisions outlined in this condition. The applicant shall pay to the City upon demand any amount owed to the City under the indemnification requirements prescribed in this condition. Fire Department 22. A fire sprinkler deferred submittal shall be required. 23. A fire alarm deferred submittal shall be required for buildings equipped with fire alarms. 24. Services including oxygen enriched environments, hyperbaric chambers, cryogenic treatments, or introduction of other hazardous materials shall be prohibited. Introduction of any additional services shall require the review and approval by the Newport Beach Fire Department and Building Division. Building Division 25. The applicant is required to obtain all applicable permits from the City’s Building Division and Fire Department. The construction plans must comply with the most recent, City- adopted version of the California Building Code. The construction plans must meet all applicable State Disabilities Access requirements. Approval from the Orange County Health Department is required before the issuance of a building permit. 12 Attachment No. ZA 2 Vicinity Map 13 VICINITY MAP Minor Use Permit (PA2024-0079) 2210 Newport Boulevard, Unit 104 Subject Property 14 Attachment No. ZA 3 Project Plans 15 AN INTERIOR TENANT IMPROVEMENT GENERAL NOTES A4 1 A4 X A4 X LANDLORD CONTACT: BUILDING DEPARTMENT:CITY OF NEWPORT BEACH100 CIVIC CENTER DRNEWPORT BEACH, CA 92660(949)-644-3275 PROJECT NAME:SWEATHOUZ LOCAL JURISDICTION: BUILDING & SAFETY - NEWPORT BEACH CODES UTILIZED:^K^KEd,/^^,d PROPOSED USE:PERSONAL SERVICES RESTRICTED(NO MASSAGE / NO CHIROPRACTIC SERVICES)CUSTOMERS HAVE A ONE-HOUR MAXIMUM RESERVATION TO USE INDIVIDUALCONTRAST THERAPY ROOM. CUSTOMERS USE ROOM ACCORDING TO THEIRPREFERENCES AND NEEDS. TYPICAL ROOM USE IS 30-45 MINUTES IN SAUNAFOLLOWED BY COLD PLUNGE. CONSTRUCTION TYPE: IB- FULLY SPRINKLERED OCCUPANCY GROUP: B (UNDER 50 OCCUPANTS) TOTAL S.F.: 1,215 USF (USABLE SQUARE FOOTAGE) 1,265 RSF (RENTABLE SQUARE FOOTAGE) TOTAL OCCUPANT LOAD: 9 - SEE SHEET A1.1 1 EXIT(S) REQUIRED, 1 EXIT(S) PROVIDED (OCCUPANT LOAD < 50) 1 RESTROOM REQUIRED, 1 RESTROOM PROVIDED EXTERIOR SIGN UNDER SEPARATE PERMIT BY SIGN COMPANY - INSTALLED BY SIGN COMPANY 1 TENANT INFORMATION:^dW,E/^dd^KE^,EKZ>ϭ>>ϳϮϬͲϴϳϴͲϯϵϴϴ GENERAL REQUIREMENTS: A. DRAWINGS. THE DRAWINGS ARE INTENDED TO DESCRIBE THE OVERALL SCOPE OFWORK. CONTRACTORS SHALL FIELD VERIFY EXISTING CONDITIONS AND ALERTARCHITECT TO ANY UNFORESEEN CONSTRUCTION DIFFICULTIES BEFOREBEGINNING WORK. IN-FIELD REVISIONS SHALL NOT OCCUR WITHOUT ARCHITECT'SAPPROVAL. B. PRE-CONSTRUCTION MEETING. PRIOR TO ANY CONSTRUCTION OR DEVELOPMENTACTIVITY, THE CONTRACTOR SHALL SCHEDULE, WITH OWNERS APPROVAL, APRE-CONSTRUCTION MEETING WITH THE LOCAL BUILDING DEPT. OR LOCAL PUBLICWORKS DEPT. VERIFY WHICH AGENCY WOULD BE INVOLVED. THE CONTRACTORSHALL PROVIDE LOCAL INSPECTOR WITH 24 HOURS NOTICE PRIOR TO INSPECTION.C. TYPICAL WALL SECTIONS, FINISHES, AND DETAILS ARE NOT INDICATEDEVERYWHERE THEY OCCUR ON PLANS, ELEVATIONS AND SECTIONS. REFER TODETAILED DRAWINGS. CONTRACTOR TO PROVIDE AS IF DRAWN IN FULL. D. CODES / PERMITS / REGULATIONS. ALL EXTERIOR SIGNAGE MUST BE SUBMITTEDAND REVIEWED UNDER SEPARATE PERMIT APPLICATION. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS NECESSARY OTHER THANTHE BUILDING PERMIT. CONTRACTOR SHALL ALSO PAY FOR ALL OTHER CHARGES,FEES OR COSTS CHARGED BY THE BUILDING AND CONSTRUCTION DEPARTMENTS,UTILITY AGENCIES OR PRIVATE COMPANIES WHICH REQUIRE SUCH COSTS FOR ORPRIOR TO INSTALLATIONS. NOTHING IN THE DRAWINGS SHALL BE CONSTRUCTED TO PERMIT AN INSTALLATIONIN VIOLATION OF APPLICABLE CODES AND/OR RESTRICTIONS. SHOULD ANYCHANGE IN THE DRAWINGS BE NECESSARY IN ORDER TO COMPLY WITHAPPLICABLE CODES AND/OR REQUIREMENTS, THE CONTRACTOR SHALL NOTIFYTHE ARCHITECT AT ONCE AND CEASE WORK. ALL PARTS PERFORMED UNDER THISCONTRACT SHALL BE IN FULL ACCORDANCE WITH THE LATEST RULES,REGULATIONS, RESTRICTIONS, REQUIREMENTS AND CODES. AMENDED BY GOVERNING CITY & ALL JURISDICTION RULES AND REGULATIONS.E. DIMENSIONS ARE SHOWN TO FACE OF MASONRY OR CENTERLINE OF OPENING,UNLESS DETAILED OTHERWISE ON DRAWINGS. DO NOT SCALE DRAWINGS. THE CONTRACTOR SHALL USE DIMENSIONS SHOWN ONTHE DRAWINGS AND ACTUAL FIELD MEASUREMENTS. NOTIFY THE ARCHITECT IFANY DISCREPANCIES ARE FOUND. THE CONTRACTOR SHALL VERIFY ALL ROUGH-IN DIMENSIONS FOR THE EQUIPMENTFURNISHED AND INSTALLED BY HIMSELF/HERSELF OR OTHERS. THE CONTRACTOR SHALL CONSULT THE PLANS OF ALL TRADES FOR OPENINGSTHROUGH SLABS, WALLS, CEILINGS AND ROOFS. F. SHOP DRAWINGS REVIEW. PROVIDE SHOP DRAWINGS FOR THEARCHITECTS/OWNERS AND AS REQUIRED BY THE CITY PRIOR TO CONSTRUCTION. G. CONTRACTOR TO FRAME OPENINGS IN WALLS, CEILINGS AND FLOORS FOR H.V.A.C.AND OTHER MECHANICAL OR ELECTRICAL WORK WHERE REQUIRED AND NOTOTHERWISE SHOWN ON THE PLANS. H. COMPLY WITH APPLICABLE REGULATIONS FOR BARRIER-FREE FACILITIESINCLUDING: 1). MAXIMUM THRESHOLD HEIGHT TO BE ONE HALF INCH (1/2") ALONG ACCESSIBLE ROUTE OF TRAVEL.2). STAIR NOSINGS TO BE FLUSH, SLIP RESISTANT AND ROUNDED TO RADIUS OFONE HALF INCH (1/2")MAXIMUM. DOORS/WINDOWS: A. GLAZING. PROVIDE GLAZING PER CITY CODES:INSULATED UNITS SHALL BE CLASS 40 GLAZING WITH LOW ARGON GAS. GLAZING IN LOCATIONS SUBJECT TO HUMAN IMPACT SUCH AS PANES IN DOORS,GLAZING WITHIN A 24" ARC OF A DOOR OPENING, GLAZING WITHIN 18" OF THEFLOOR (AND IS OVER 9 SQ. FT. PER PANEL) SHALL BE TEMPERED GLASS ORLAMINATED SAFETY GLASS PER CODE. GLAZING U-VALUE (AMMA TESTED) U-40 MAXIMUM. FIRE PROTECTION: (FIRE SPRINKLER T.I. REQUIRED) A. GC TO EXTEND THE EXISTING AUTOMATIC FIRE SPRINKLER SYSTEM AS REQUIRED.GET SYSTEM DESIGN APPROVED BY GOVERNING CITY'S BUILDING DEPARTMENT ANDFIRE DEPARTMENT PRIOR TO INSTALLATIONNOTE: GC TO PROVIDE LIFE SAFETY MANAGEMENT IN THEIR BIDDING PROCESS B. PROVIDE FIRE EXTINGUISHERS AS REQUIRED BY INTERNATIONAL BUILDING CODEAND LOCATE PER FIRE MARSHAL'S DIRECTION. 1 FIRE EXTINGUISHER PER 3,000 S.F.OF BUILDING AREA WITHIN 75'-0" TRAVEL DISTANCE BETWEEN EXTINGUISHERS. C. MAINTAIN STRUCTURAL AND FIRE RESISTIVE INTEGRITY AT EXTERIOR AND RATEDINTERIOR WALL PENETRATIONS FOR ELECTRICAL, MECHANICAL, PLUMBING ANDCOMMUNICATIONS CONDUITS, PIPED AND SIMILAR SYSTEMS PER CITY'S CODE. THERMAL/MOISTURE PROTECTION: A. OPENINGS. ALL OPENINGS TO BE CAULKED, SEALED OR WEATHER-STRIPPED. ALL FLASHING AND ARCHITECTURAL SHEET METAL TO BE 24 GAUGE GALVANIZEDSTEEL, FACTORY PRIMED AND FIELD PAINTED. 10'-0" LENGTHS, PER SMACNAMANUAL UNLESS OTHERWISE NOTED. B. CAULKING AND SEALANTS. USE PRIMERS AS REQUIRED BY MANUFACTURER.BACKING RODS OR TAPE AS RECOMMENDED BY MANUFACTURER. USEPOLYURETHANE SEALANTS AT CONCRETE FLOOR AND SIDEWALK JOINTS. ALLOTHER LOCATIONS USE POLYSULFIDE OR SILICONE. C. VAPOR BARRIERS. CONTINUOUS APPROVED VAPOR BARRIERS SHALL BEINSTALLED ON THE HEATED SIDE OF ALL THERMAL INSULATION INSTALLED. D. INSULATION. PROVIDE INSULATION PER LOCAL CODE, COMPONENT PERFORMANCEAPPROACH. GENERAL NOTES: 1. PRIOR TO DEMOLITION, VERIFY IN FIELD EXISTING WALLS AND IF ANY STRUCTURAL COLUMNS EXIST.IF SO, CONTACT ARCHITECT IMMEDIATELY. 2. CONTRACTOR TO MAINTAIN PROPER LIGHTING, SANITATION AND VENTILATION AT ALL TIMES. 3. ALL WORK MUST BE APPROVED BY BUILDING INSPECTOR PRIOR TO COVERING WORK. 4. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN A WATER AND WEATHER TIGHTBUILDING. 5. ALL WORK TO BE PERFORMED TO CODE BY LICENSE CONTRACTORS PERFORMING WORK IN THEIRSPECIFIC TRADE ONLY. 6. ALL DESIGN, DRAWINGS, AND DETAILS REPRESENT COMPLETE WORK IN PLACE. ARCHITECT SHALLHAVE NO CONTROL OR CHANGE OF AND SHALL NOT BE RESPONSIBLE FOR CONSTRUCTION. 7. INTERIOR PARTITIONS NOTED ON PLANS MAY BE SHOWN AS NOMINAL DIMENSIONS, SUCH AS 5"INTERIOR WALL REFERS TO GYPSUM BOARD EACH OVER 3-5/8" STUDS. STUD SPACING IS 24" O.C. 8. ALL DEBRIS GENERATED FROM CONSTRUCTION MUST BE KEPT ON THE SITE IN EITHER AN ENCLOSEDAREA OR HAULED AWAY DAILY, AND DISPOSED OF LEGALLY OFF-SITE. 9. EXTERIOR SIGNAGE IS NOT PART OF THIS CONTRACT OR PERMIT EXCEPT ELECTRICAL ROUGH-IN ANDBLOCKING. SIGN CONTRACTOR SHALL MAKE SEPARATE SUBMITTAL TO THE CITY FOR REVIEW ANDPERMIT. 10. KEEP ALL PIPING AND CONDUIT AS CLOSE TO WALLS AND ROOF DECK AS POSSIBLE AND ALLDUCTWORK AS CLOSE TO ROOF AS POSSIBLE. WHERE EXPOSED, ALL PIPING CONDUIT ANDDUCTWORK SHALL BE PAINTED UNLESS NOTED. ALL PIPING CONDUIT SHALL BE ORGANIZED IN A NEATMANNER RUNNING PARALLEL OR PERPENDICULAR TO ROOF FRAMING MEMBERS. 11. MAXIMUM FLAME SPREAD CLASSIFICATION OF FINISH MATERIALS USED ON INTERIOR WALLS ANDCEILING SHALL NOT EXCEED THAT SET FORTH IN FLAME SPREAD TABLE OF THE BUILDING CODE. 12. VERIFY ALL DIMENSIONS IN THE FIELD PRIOR TO CONSTRUCTION AND COORDINATE WITH ARCHITECTANY CONFLICTS WITH THE PLANS. 13. PERFORM THE REMOVAL, CUTTING, AND DRILLING WITH THE CARE USE OF THE SMALLEST TOOLS SOAS TO NOT DAMAGE THE STRUCTURAL INTEGRITY OF THE BUILDING. 14. TO SAW CUT AT EXISTING RESTROOM LOCATION, USE SAWS AND COREDRILLS. DO NOT USEJACKHAMMER UNDER ANY CIRCUMSTANCES. 15. GC TO COORDINATE FIRE ALARM INSTALL WITH LANDLORD, IF REQUIRED BY CITY. ACP ACOUSTICAL CLG. PANELACT ACOUSTICAL CLG. TILEAL ALUMINUMALUM ALUMINUMARCH ARCHITECTURALAVG AVERAGEBLDG BUILDINGBLKG BLOCKINGBR BRICKCMU CONCRETE BLOCKCT CERAMIC TILECFM CUBIC FEET PER MINUTECL CENTER LINECLG CEILINGCONC CONCRETECONT CONTINUOUSCW COLD WATERDTL DETAILDF DRINKING FOUNTAINDIA DIAMETERDIM DIMENSIONDN DOWNDR DOORDS DOWNSPOUTDWG DRAWINGEA EACHELEV ELEVATIONEXIST EXISTINGOR EXEXT EXTERIORFDN FOUNDATIONFIN FINISHFD FLOOR DRAINFL FLOOR FLASH FLASHINGFOIC FURNISHED BY OWNERINSTALLED BY CONTRACTORFO FINISH OPENINGFRP FIBERGLASS REINFORCEDPANELSFRT FIRE RETARDANT TREATEDGA GAUGEGALV GALVANIZEDGL GLASSGWB GYPSUM WALLBOARDHDWE HARDWAREHM HOLLOW METALHOR HORIZONTALHT HEIGHTHW HOT WATERHWH HOT WATER HEATERHWT HOT WATER TANKLAV LAVATORYLT LIGHTMAT'L MATERIALMAX MAXIMUMMTL METALMIN MINIMUMMO MASONRY OPENINGMUL MULLIONN/A NOT APPLICABLENIC NOT IN THIS CONTRACTNO NUMBERNOM NOMINALNTS NOT TO SCALEOC ON CENTEROD OUTSIDE DIMENSIONPT PAINT PLAM PLASTIC LAMINATEPLYWD PLYWOODR RISER, RADIUSREBAR REINFORCING BARREF REFERENCEREV REVISIONRM, RMS ROOM, ROOMSRO ROUGH OPENINGS & V SATIN AND VARNISHSC SOLID CORESCHED SCHEDULESEC SECTIONSHT SHEETSPECS SPECIFICATIONSSF SQUARE FEETST STEELSTOR STORAGESTRUCT STRUCTURALSUSP SUSPENDEDSV SHEET VINYLSS STAINLESS STEELTB TELEPHONE MOUNTING BOARDTD TRENCH DRAINTHRESH THRESHOLDTYP TYPICALUNFIN UNFINISHEDUR URINALVCT VINYL COMPOSITION TILEVERT VERTICALVST VINYL SAFETY TILEW WIDTHWC WATER CLOSETWD WOODWDW WINDOWWP WATERPROOF COVER SHEET A0.0 A0.0 TITLE SHEETA0.1 EXISTING SITE PLAN FOR REFERENCE ONLYA0.2 2022 CA GREEN BUILDING CODEA0.3 2022 CA GREEN BUILDING CODEA0.4 2022 CA GREEN BUILDING CODEA0.5 CHAPT 11B DETAILSA0.6 CHAPT 11B DETAILSA1.1 EGRESS / EXIT PLANA1.3 EXISTING PLAN / DEMO PLAN / LANDLORD COMMENTSA2.0 FLOOR PLANA2.1 DIMENSIONED PLANA2.2 DOOR SCHEDULE / DETAILSA2.3 ENLARGED FLOOR PLANSA3.0 REFLECTED CEILING PLANA4.0 INTERIOR ELEVATIONSA4.1 INTERIOR ELEVATIONSA5.0 FINISH PLAN AND SCHEDULESA6.0 DETAILSA7.0 SPECIFICATIONSA7.1 SPECIFICATIONS M0.1 MECHANICAL SCHEDULESM1.0 MECHANICAL FLOOR PLANM2.0 MECHANICAL DETAILSM3.0 MECHANICAL SPECS P0.1 PLUMBING SCHEDULESP1.0 PLUMBING PLANP2.0 WASTE RISER DIAGRAMP3.0 PLUMBING DETAILSP4.0 PLUMBING SPECS E0.1 ELECTRICAL SCHEDULESE0.2 ELECTRICAL ENERGY COMPLIANCEE1.0 ELECTRICAL LIGHTING PLANE2.0 ELECTRICAL POWER PLANE2.1 ELECTRICAL HVAC FLOOR PLAN GENERAL CONTRACTOR NOTE:GC IS REQUIRED TO OBTAIN INTERIOR BRANDING GUIDE PROVIDED BYSWEATHOUZ CONSTRUCTION DURING BID PHASE AND CONFIRM LASTEDGUIDE PRIOR TO CONSTRUCTION. GC MUST REQUEST LEASE OUTLINE AND SCHEDULE SITE VISIT WITHLANDLORD DURING BID PHASE. GC IS REQUIRED TO SUBMIT X-RAYS TO STRUCTURAL ENGINEER FORREVIEW AND APPROVAL OF ALL CORE DRILL AND SLAB PENETRATIONS. Permit Number: SEPARATE PERMITS ARE REQUIRED FOR EXTERIOR SIGNS REVIEW SET DATED: 8.12.2024 PROJECT MANAGEMENT INFORMATION:LEGACY FRANCHISE CONCEPTSSWEATHOUZATTN: MAX120 INTERSTATE N. PKWY #400ATLANTA, GA 30339(MAX) 770-778-8871 INTERIOR REMODEL ONLY GC TO REFER TO THE SWEATHOUZ DESIGN GUIDE. GC MUST OBTAIN SPECS OF ALL EQUIPMENT NO SITE WORK IS TO BE PERFORMED UNDER THIS PERMIT. INTERIOR TENANT IMPROVEMENT WITHIN INTERIOR OF PERMITTED SHELL BUILDING A&E PROJECT MANAGER:ATTN: CHRIS NEAL, PROJECT MGR6501 E. Greenway Pkwy #103-707SCOTTSDALE, AZ 85254P: 480.297.5577info@neptunedg.com SCOPE OF WORK:INTERIOR TENANT IMPROVEMENT OF A WELLNESS STUDIO, PROVIDING SINGLE-USE CONTRASTTHERAPY SUITES WITH PREFABRICATED SAUNA AND COLD PLUNGE.TENANT SPACE IS LOCATED WITHIN A RECENTLY VACATED SHELL BUILDING . THIS WILL BE A2ND GENERATION TENANT WITHIN THIS SPACE. SEE MECHANICAL / ELECTRICAL AND PLUMBINGPLANS FOR ADDITIONAL INFORMATION. TENANT'S GC TO COORDINATE APPROVAL PERMITS AND CONNECTIONS FOR THE FIRE ALARM. GENERAL CONTRACTOR NOTE:THE GC MUST SUBMIT SEPARATE DRAWINGS FOR SPRINKLER AND FIRE ALARM WORKAND SHALL BE UNDER SEPARATE PERMIT. SIGNAGE UNDER A SEPARATE PERMIT SWEATHOUZ INFRARED SAUNA COLD PLUNGE INDEX OF SHEETS CONTACT INFORMATION ABBREVIATIONS REFERENCE SYMBOLS PROJECT DATA 105 101 VICINITY MAP ZONING COMMENTS:A CERTIFICATE OF OCCUPANCY IS REQUIRED FOR THIS SPACE.NO SIGNAGE APPROVALS ARE INCLUDED UNDER THIS PERMIT A SEPARATE SIGN PERMIT ISREQUIRED FOR ANY TENANT SIGNAGE. DOOR TAG ROOM TAG DETAIL REFERENCE REVISION ELEVATION REFERENCE WALL SECTION REFERENCE EQUIPMENT REFERENCE 1 GOVERNING CODES:ALL WORK SHALL BE IN COMPLIANCE WITH, BUT NOT LIMITED TO THEREQUIREMENTS OF THE FOLLOWING AND ANY OTHER STATE AND LOCALCODES HAVING JURISDICTION: BUILDING: 2022 CALIFORNIA BUILDING CODE MECHANICAL: 2022 CALIFORNIA MECHANICAL CODE PLUMBING: 2022 CALIFORNIA PLUMBING CODE ELECTRICAL: 2022 CALIFORNIA ELECTRICAL CODE ENERGY: 2022 CALIFORNIA BUILDING ENERGY EFFICIENCY STANDARDS ACCESSIBILITY: THE AMERICANS WITH DISABILITIES ACT AND IMPLEMENTING RULES ADDITIONAL: 2022 CALIFORNIA REFERENCED STANDARDS CODE FIRE: 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE REVISION 1 2 3 DATE: 5.29.2024 REVIEW SETNOT FORPERMIT 22 1 0 N E W P O R T B L V D S T E . 1 0 4 NE W P O R T B E A C H , C A STORE NO.: SW E A T H O U Z IN F R A R E D S A U N A CO L D P L U N G E THIS DRAWING IS AN INSTRUMENT OFSERVICE AND AS SUCH SHALL REMAINTHE PROPERTY OF ND ENTERPRISES,LLC. UNAUTHORIZED USE OFREPRODUCTION WITHOUT PERMISSIONOF THE ARCHITECT IS PROHIBITED. THISDRAWING IS ONLY FOR USE INCONNECTION WITH THIS PROJECT ANDSHALL NOT BE USED FOR OTHERLOCATIONS . COPYRIGHT 2024. ND E N T E R P R I S E S , L L C 65 0 1 E . G R E E N W A Y P K W Y # 1 0 3 - 7 0 7 S C O T T S D A L E , A Z 8 5 2 5 4 P 4 8 0 - 2 9 7 - 5 5 7 7 w w w . n d e n t a z . c o m PLANNING DEPT.08.12.2024 2210 NEWPORT BLVD STE. 104 NEWPORT BEACH, CA PREVIOUSLY APPROVED SHELL BUILDING UNDER PLAN CHECK NUMBER 2363-2010 1 1 1 1 1 LAND USEPREVIOUS USE (RETAIL)PARKING REQUIRED1 / 250 SQ.F.T PARKING TABULATION: PROPOSED USE 1 / 250 SQ.F.T(PERSONAL SERVICES, RESTRICTED) 1 16 EXISTINGSITE PLAN A0.1 REVISION 1 2 3 DATE: 5.29.2024 REVIEW SETNOT FORPERMIT 22 1 0 N E W P O R T B L V D S T E . 1 0 4 NE W P O R T B E A C H , C A STORE NO.: SW E A T H O U Z IN F R A R E D S A U N A CO L D P L U N G E THIS DRAWING IS AN INSTRUMENT OFSERVICE AND AS SUCH SHALL REMAINTHE PROPERTY OF ND ENTERPRISES,LLC. UNAUTHORIZED USE OFREPRODUCTION WITHOUT PERMISSIONOF THE ARCHITECT IS PROHIBITED. THISDRAWING IS ONLY FOR USE INCONNECTION WITH THIS PROJECT ANDSHALL NOT BE USED FOR OTHERLOCATIONS . COPYRIGHT 2024. ND E N T E R P R I S E S , L L C 65 0 1 E . G R E E N W A Y P K W Y # 1 0 3 - 7 0 7 S C O T T S D A L E , A Z 8 5 2 5 4 P 4 8 0 - 2 9 7 - 5 5 7 7 w w w . n d e n t a z . c o m CITY COMMENTS08.12.2024 RE F E R E N C E O N L Y - R E F E R E N C E O N L Y - R E F E R E N C E O N L Y THIS PROJECT BUILDING B, SUITE 104 SWEATHOUZ 3 3 3 17 ACCESSIBLE UNISEX110 CONTRASTTHERAPYROOM 104 CONTRASTTHERAPYROOM 103 CONTRASTTHERAPYROOM 102 CONTRASTTHERAPYROOM 106 BEAUTY BAR 108 CONTRAST THERAPYROOM 105 107 ACCESSIBLECONTRAST THERAPYROOM RECEPTION 100 UTILITYROOM109 CLOSET 111 24x36SHELF 3'-1 1 3 / 8 " 3'-1 1 / 8 " 3'-2" RA M P ADA 2022 CBC / PER TABLE 1004.5 TOTAL SF: 1,215 U.S.F. (USABLE SQUARE FOOTAGE)1,265 R.D.F. (RENTABLE SQUARE FOOTAGE) ALL AREASBUSINESS 1,215 SF / 150 = 9 OCCUPANTS THIS PROJECT: TOTAL OCCUPANT LOAD: 9 OCCUPANTS 1 EXIT REQUIRED1 EXITS PROVIDED 1 Overall length of building 36'-9" 1 Ov e r a l l l e n g t h o f b u i l d i n g 3 1 ' - 4 " A1.1 EGRESS PLAN G.C. COMPLIANCE: OWNER'S GENERAL CONTRACTOR SHALL VISIT THE PREMISES AND VERIFY ALL EXISTING CONDITIONS PRIOR TO STARTOF CONSTRUCTION AND SHALL REPORT ALL DISCREPANCIES TO TENANT'S ARCHITECT. TENANT'S GENERALCONTRACTOR SHALL CONFORM TO ALL REQUIREMENTS REGARDING CONSTRUCTION PROCEDURES, INSURANCE, ETC.,AS SEAT FORTH BY THE LANDLORD. G.C. COMPLIANCE:OWNER'S SIGNAGE CONTRACTOR SHALL PREPARE SIGNAGE SHOP DRAWINGS AND SUBMIT TO BUILDING DEPT. &LANDLORD FOR APPROVAL. ALL SIGNAGE IS UNDER SEPARATE PERMIT. 1. THE RELATIONSHIP BETWEEN FLOOR DRAINS / SINKS AND NEW WALLS IS CRITICAL TO THE FINAL FIXTURE / EQUIPMENTLAYOUT. FLOOR SINKS AS SHOWN ON THE PLUMBING PLANS ARE DIMENSIONALLY LOCATED OFF OF NEW PARTITIONS, ANDTHEREFORE THE CONTRACTOR MUST COMPLETE PLAN LAYOUT ON SLAB PRIOR TO FINAL LOCATION OF FLOOR SINKS FORACCURATE FINAL PLACEMENT.2. STRUCTURAL ENGINEER MUST REVIEW ANY AND ALL CORE DRILLS AND PENETRATION LOCATIONS PRIOR TO DRILLING.3. GC TO COORDINATE IN THE FIELD WITH ENGINEER AND PROVIDE ACCESS AND THIS SCOPE WITHIN BID. CONSTRUCTION NOTES ARCHITECT'S DESIGN WITHOUT CONSTRUCTION PHASE SERVICES SINCE DIRECT CONSTRUCTION OBSERVATIONS AND REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT INCLUDED ASPART OF THE ARCHITECT'S BASIC SERVICES, IT IS UNDERSTOOD THAT SUCH RESPONSIBILITIES WILL BE ASSUMED BY OTHERS.ARCHITECT AVAILS ITSELF TO THE CLIENT, THE CONTRACTOR, AND ANY OTHER PARTIES AS NECESSARY (VIA TELEPHONE, FAX,AND EMAIL) IN ORDER TO ASSIST IN PROVIDING CLARIFICATIONS OR RESOLVING ISSUES AND PROBLEMS THAT MAY ARISE.ALTHOUGH MANY ISSUES CAN BE EASILY ADDRESSED WITHOUT THE ARCHITECTS INVOLVEMENT, THERE ARE TIMES WHENPARTICIPATION IS ADVISABLE. DETERMINATION OF WHEN INVOLVEMENT IS APPROPRIATE IS LEFT TO THE PROFESSIONALDISCRETION OF THE CONTRACTOR. IT IS UNDERSTOOD THAT THE CLIENT AND/OR THE CONTRACTOR ASSUMES ALLRESPONSIBILITY FOR INTERPRETATION OF THE DRAWINGS, AND ANY OTHER SUPPLEMENTAL INFORMATION, AND WHEN THEARCHITECT IS DENIED THE OPPORTUNITY TO PROVIDE CLARIFICATIONS OR PARTICIPATE IN CHANGES TO THE DESIGN OR THERESOLUTION OF ISSUES OR PROBLEMS, ALL PARTIES WAIVE ANY CLAIMS AGAINST THE ARCHITECT THAT MAY BE IN ANY WAYCONNECTED THERETO. ARCHITECT IS HELD HARMLESS FROM LOSS, CLAIM, OR COSTS ARISING OR RESULTING FROMMODIFICATIONS OR CHANGES MADE TO THE DESIGN (WITHOUT THE KNOWLEDGE OF THE ARCHITECT) DUE TO CONDITIONS ORCIRCUMSTANCES (ANTICIPATED OR NOT) BEYOND THE ARCHITECT'S CONTROL. MECHANICAL, PLUMBING AND ELECTRICAL NOTES LEGEND EXIT SIGN, CONFIRM LOCATIONREQUIREMENTS WITH FIRE MARSHAL EGRESS PATH OF TRAVEL FE NOTE:EVERY ROOM OR SPACE THAT IS A BUILDING OCCUPANCY SHALLHAVE THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN ACONSPICUOUS PLACE, NEAR THE MAIN EXIT OR EXIT ACCESSDOORWAY FROM THE ROOM OR SPACE. POSTED SIGNS SHALL BEOF AN APPROVED LEGIBLE PERMANENT DESIGN AND SHALL BEMAINTAINED BY THE OWNER OR AUTHORIZED AGENT. EXISTING DEMISING WALL FIRE EXTINGUISHER SCALE: NORTH EGRESS / OCCUPANCY PLAN 1/4" = 1'-0"1 18" CL 3'-0 " T.O . G R I P P I N G S U R F A C E 1'-0" MIN. 2'-0" MIN. 3'-0" MIN. CLCL 1'-0" MAX. 3'-6" MIN. 4'-6" MIN. 19 " M I N . TO O U T L E T 1'- 6 " T.O . S E A T TOILET PAPER DISPENSER CL CL SEE DETAIL 3/A1.1FOR BLOCKING ATGRAB BARS 12"ROUGH-IN 9"CL CL 3'-5" 3'- 5 " 1'- 6 " MIN . CL CL CL SCALE: 1/2" = 1'-0" ACCESSIBLE WATER CLOSET ELEVATIONS2 A1.1 GRABBARS SANITARY NAPKINDISPENSER 2'- 6 " GRAB BAR SECTION3 A1.1 SCALE: N.T.S. GRAB BAR SPECIFICATIONS: BOBRICK B6806x36 (36" GRABBAR BEHIND WATER CLOSET) BOBRICK B6806x42 (42" GRABBAR AT WALL ADJACENT TOWATER CLOSET) WALL 1 1/4"TO 2"112"F.R.T. BLOCKING , TYP.FOR ALL GRAB BARLOCATIONS PEENEDGRIP 1 1 / 2 " CL R . 1'-0 " C L R . F R O M AN Y O B S T R U C T I O N A1.1 SCALE: 1/2" = 1'-0" 1 17" - 25" 48" MIN. 17" - 25" 2'- 1 0 " M A X . T O RIM O F S I N K 2'-3 " M I N . 9" M I N . HOT WATER AND DRAIN PIPESUNDER LAVATORIES SHALL BEINSULATED OR OTHERWISECONFIGURED TO PROTECTAGAINST CONTACT PER ADAREGULATIONS NO OTHER FIXTURESPERMITTED IN CLEARFLOOR AREA ELEVATION PLAN ACCESSIBLE LAVATORY PLAN & ELEVATION 30" M I N . 6" MAX.8" MIN. 18" RESTROOM WALL 6'- 2 " M I N . T O R E F L E C T I V E S U R F A C E 3'-4 " M A X T O RE F L E C T I V E S U R F A C E 2 ' - 1 0 " MIRROR SPECIFICATIONS: SENTRY MIRROR - (24" x 36") www.sentrymirror.com NOTES:1.CHARACTERS, SYMBOLS AND THEIR BACKGROUND SHALL HAVE A NON-GLARE FINISH. CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIRBACKGROUND.2.CHARACTERS ON SIGNS SHALL BE RAISED 1/32" MINIMUM & SHALL BE SANS SERIF UPPERCASE CHARACTERS. CHARACTERS SHALL BE A MINIMUM OF 5/8"AND A MAXIMUM OF 2" HIGH.3.BRAILLE SHALL BE GRADE 2 AND SHALL COMPLY SIZE AND SPACING REQUIREMENTS IN THE ACCESSIBILITY CODE. BRAILLE CHARACTERS SHALL BELOCATED BELOW THE SIGN TEXT, WITH A 3/8" MINIMUM SPACE BETWEEN BRAILLE AND TEXT OR OTHER SIGNAGE ELEMENTS (BORDER, PICTOGRAM, ETC).4.PICTOGRAMS SHALL BE ACCOMPANIED BY THE VERBAL DESCRIPTION PLACED DIRECTLY BELOW THE PICTOGRAM. THE OUTSIDE DIMENSION OF THEPICTOGRAM FIELD SHALL BE A MINIMUM OF 6" IN HEIGHT. SCALE: N.T.S.4 A1.1 SIGN DETAILS 9"CL TYPICAL ROOM / EXIT SIGNS SIGNAGE CHARACTER HEIGHT NOTES:A.48" MIN. A.F.F. TO BASE LINE OF LOWEST BRAILLE.B.60" MAX. A.F.F. TO BASE LINE OF HIGHEST BRAILLE.C.48" MIN. A.F.F. TO BASE LINE OF LOWEST RAISED CHARACTER.D.60" MAX. A.F.F. TO BASE LINE OF HIGHEST RAISED CHARACTER.SE E N O T E : A SE E N O T E : B SE E N O T E : C SE E N O T E : D LATCH SIDEOF DOOR SIGNTEXT RESTROOM FE FE COMMON PATH OF TRAVELDISTANCE: 34-11" (MAX)36" MIN CLEAR SPACEREQUIRED REVISION 1 2 3 DATE: 5.29.2024 REVIEW SETNOT FORPERMIT 22 1 0 N E W P O R T B L V D S T E . 1 0 4 NE W P O R T B E A C H , C A STORE NO.: SW E A T H O U Z IN F R A R E D S A U N A CO L D P L U N G E THIS DRAWING IS AN INSTRUMENT OFSERVICE AND AS SUCH SHALL REMAINTHE PROPERTY OF ND ENTERPRISES,LLC. UNAUTHORIZED USE OFREPRODUCTION WITHOUT PERMISSIONOF THE ARCHITECT IS PROHIBITED. THISDRAWING IS ONLY FOR USE INCONNECTION WITH THIS PROJECT ANDSHALL NOT BE USED FOR OTHERLOCATIONS . COPYRIGHT 2024. ND E N T E R P R I S E S , L L C 65 0 1 E . G R E E N W A Y P K W Y # 1 0 3 - 7 0 7 S C O T T S D A L E , A Z 8 5 2 5 4 P 4 8 0 - 2 9 7 - 5 5 7 7 w w w . n d e n t a z . c o m CITY COMMENTS08.12.2024 COMMON PATH OF TRAVELDISTANCE: 30-6" (MAX)36" MIN CLEAR SPACEREQUIRED 1 18 19