Loading...
HomeMy WebLinkAboutMODP ROJECT R EVIEW R EQUEST C O M M U N I T Y D E V E L O P M E N T D E P AR T M E N T Planning Division Please Distribute to: Code Enforcement – M. Cosylion Building/Life Safety Services – S. Jurjis (2 Sets) Public Works – Brine/Keely/Cho Police Dept. – D. Psaros (Telecom) Municipal Operations – George Murdoch Date: May 31, 2016 Please return PRR and Plans to Staff Planner Jason Van Patten, Assistant Planner (949) 644-3234, jvanpatten@newportbeachca.gov Applicant: California Transmission Network Contact: Shanna Reyes 949-402-5005 shanna.reyes@itbutility.com Project Name 2524 (CS) Eastbluff Drive Telecom Facility Address: Near Eastbluff Drive and Bixia Street (PA2016-076) UP2016-018 A minor use permit for a Class 3 (Public Right-of-Way Installation) telecom facility mounted to an existing streetlight. The proposed wireless facility will consist of one omni directional antenna, one UE relay, one GPS antenna, one remote radio head, one disconnect switch, one AC distribution panel. The proposed height measures 29’5” from grade. If approved for a minor use permit, projet requires a City approved license agreement. REPORT REQUESTED BY: June 14, 2016 ZONING ADMINISTRATOR HEARING DATE: TBD Check all that apply:  No comments on the project as presented. Notes: On page E-1 note indicates to use street lighting existing 240ac power source which is not possible because the power source is 5,000 volts ac power source. A new source of power will have to be installed by SCE and that power source cannot share the same conduit with the high voltage circuit. There are no 240vac street lighting circuits in the Eastbluff housing development. A new service pedestal will have to be installed by SCE to get the required power. A broader discussion about the location and power options needs to take place. The other issue is the close proximity to residences and the RF levels being outputted by the transmitter, the potentially affected residents need to informed before final permitting approval. Signature Ext. Date  Application of Standard Code requirements are not expected to alter the project design.  Recommended conditions of approval are attached.  Application of Standard Code requirements or the attached conditions of approval will substantially impact or alter the design of the project.  I contacted the applicant on  To schedule an appt. for Code review  To discuss the following (see notes) Please indicate the approximate time spent on reviewing this project: