Loading...
HomeMy WebLinkAbout03_Tang Residence Modification Permit_PA2024-0187CITY OF NEWPORT BEACH ZONING ADMINISTRATOR STAFF REPORT December 12, 2024 Agenda Item No. 3 SUBJECT: Tang Residence (PA2024-0187) Modification Permit SITE LOCATION: 1935 Port Cardiff Place APPLICANT: Dana Kwon OWNER: John Tang PLANNER: Daniel Kopshever, Assistant Planner dkopshever@newportbeachca.gov or 949-644-3235 LAND USE AND ZONING General Plan Land Use Plan Category: RS-D (Single Unit Residential Detached) Zoning District: PC 3 (Harbor View Hills) PROJECT SUMMARY A request for a modification permit to allow a 1,140-square-foot addition to an existing 2,508-square-foot single-unit residence with nonconforming parking. Title 20 (Planning and Zoning) of the Newport Beach Municipal Code (NBMC) limits additions to a maximum of 10% of the existing gross floor area when a residence has nonconforming parking. The existing garage is considered nonconforming due to depth, as the garage only provides an interior clear dimension of 19 feet, 9 inches, when 20 feet is required. The addition otherwise complies with all applicable development standards and no other deviations are requested. RECOMMENDATION 1) Conduct a public hearing; 2) Find this project exempt from the California Environmental Quality Act (CEQA) pursuant to Section 15301 under Class 1 (Existing Facilities) of the CEQA Guidelines, because it has no potential to have a significant effect on the environment; and 3) Adopt Draft Zoning Administrator Resolution No. _ approving the Modification Permit filed as PA2024-0187 (Attachment No. ZA 1). 1 Tang Residence (PA2024-0187) Zoning Administrator, December 12, 2024 Page 2 DISCUSSION  The Property is zoned PC 3 (Harbor View Hills) and is located within the Low/Medium Density Residential subarea (Area 2). This subarea allows for the development of detached, single-unit residences.  The surrounding neighborhood is developed with both single-story and two-story, single-unit residences. There is a Metropolitan Water District facility located approximately 320 feet east of the Property, at the corner of Port Cardiff Place and East Newport Hills Drive.  The Property was originally developed in 1969 with a two-story, single-unit, residence. There is an attached, 476-square-foot, two-car, garage at the front of the residence.  The interior clear dimensions of the garage measure 20 feet wide by 19 feet, 9 inches deep. The garage was compliant with the zoning standards in place at the time of construction, which then required a minimum interior width of 8 feet, 3 inches and a minimum interior depth of 18 feet. As the result of subsequent amendments to the Zoning Code, the garage is now substandard in size and is considered legal nonconforming. Subject Property 2 Tang Residence (PA2024-0187) Zoning Administrator, December 12, 2024 Page 3  While PC 3 specifies the number of required parking spaces, it does not specify the required interior dimensions. PC 3 defers to the development standards provided within the NBMC, when not otherwise specified.  Section 20.38.060 (Nonconforming Parking) of the NBMC limits additions to residential structures with nonconforming parking to a maximum of 10% of the existing floor area within a 10-year period. Subsection (2)(b) however allows for larger additions, subject to the approval of a modification permit.  The proposed 1,140-square-foot addition is to accommodate the construction of a bedroom, living room, pantry, and bathroom on the first floor and a new balcony, laundry room, and bathroom alterations on the second floor. The areas of addition will not exceed the maximum height allowed by PC 3 and are consistent with the size of other properties in the neighborhood. The proposed addition complies with all other applicable development standards including lot coverage and setbacks.  The scope of work described above does not require modification to the garage. Increasing the scope of work to include modifications to the depth of the garage would require major structural alterations and significant cost while providing negligible benefit.  Given the intent of the project is to provide a bedroom, living room, pantry, and bathroom on the first floor and a new balcony, laundry room, and two bathrooms on the second floor, a redesign to reduce the size of the addition to 250.8 square feet, i.e. 10% of the existing floor area of the structure, will significantly impact the objectives of the project and would not provide similar benefits to the applicant.  The garage provides two useable parking spaces that are only substandard by three inches. The existing conditions fulfill the intent of the NBMC by providing adequate parking onsite. The applicant will continue to use the existing two-car garage and park onsite.  The driveway in front of the garage allows for additional onsite parking. Although the driveway parking spaces do not count toward the parking requirement for single-unit dwellings, Section 20.40.090 (Parking Standards for Residential Uses) of the NBMC allows parking of vehicles on driveways within front setback areas that are in front of garages set back a minimum of 20 feet from the front property line. The driveway measures approximately 20 feet wide by 20 feet, 4 inches, deep, which complies with the minimum depth required by the NBMC. A larger vehicle can use the driveway, which offsets the shorter parking space inside the garage. 3 Tang Residence (PA2024-0187) Zoning Administrator, December 12, 2024 Page 4 ENVIRONMENTAL REVIEW This project is exempt from the California Environmental Quality Act (CEQA) pursuant to Section 15301 under Class 1 (Existing Facilities) of the CEQA Guidelines, California Code of Regulations, Title 14, Chapter 3, because it has no potential to have a significant effect on the environment. PUBLIC NOTICE Notice of this public hearing was published in the Daily Pilot, mailed to all owners of property within 300 feet of the boundaries of the site (excluding intervening rights-of-way and waterways), including the applicant, and posted on the subject property at least 10 days before the scheduled hearing, consistent with the provisions of the Municipal Code. Additionally, the item appeared on the agenda for this meeting, which was posted at City Hall and on the city website. APPEAL PERIOD: An appeal or call for review may be filed with the Director of Community Development within 14 days following the date of action. For additional information on filing an appeal, contact the Planning Division at 949-644-3200. Prepared by: DL/djk Attachments: ZA 1 Draft Resolution ZA 2 Vicinity Map ZA 3 Project Plans 4 Attachment No. ZA 1 Draft Resolution 5 RESOLUTION NO. ZA2024-### A RESOLUTION OF THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH, CALIFORNIA, APPROVING A MODIFICATION PERMIT FOR A 45% ADDITION TO AN EXISTING SINGLE-UNIT RESIDENCE WITH A NON-CONFORMING GARAGE LOCATED AT 1935 PORT CARDIFF PLACE (PA2024- 0187) THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH HEREBY FINDS AS FOLLOWS: SECTION 1. STATEMENT OF FACTS. 1. An application was filed by Dana Kwon (Applicant), with respect to property located at 1935 Port Cardiff Place, and legally described as Lot 39 of Tract 6623 (Property), requesting approval of a modification permit. 2. The Applicant requests a modification permit to allow a 1,140-square-foot addition to an existing 2,508-square-foot single-unit residence with nonconforming parking. Title 20 (Planning and Zoning) of the Newport Beach Municipal Code (NBMC) limits additions to a maximum of 10% of the existing gross floor area when a residence has nonconforming parking. The existing garage is considered nonconforming due to depth, as the garage only provides an interior clear dimension of 19 feet, 9 inches, when 20 feet is required. The addition otherwise complies with all applicable development standards and no other deviations are requested (Project). 3. The Property is categorized as Single Unit Residential Detached (RS-D) by the General Plan Land Use Element and is located within the Harbor View Hills Planned Community (PC 3), in the Low/Medium Density Residential Area (Area 2). 4. The Property is not located within the coastal zone. 5. A public hearing was held on December 12, 2024, online via Zoom. A notice of the time, place, and purpose of the hearing was given in accordance with Chapter 20.62 (Public Hearings) of the NBMC. Evidence, both written and oral, was presented to and considered by, the Zoning Administrator at this hearing. SECTION 2. CALIFORNIA ENVIRONMENTAL QUALITY ACT DETERMINATION. 1. This Project is exempt from the California Environmental Quality Act (CEQA) pursuant to Section 15301 under Class 1 (Existing Facilities) of the CEQA Guidelines, California Code of Regulations, Title 14, Chapter 3, because it has no potential to have a significant effect on the environment. 2. This exemption includes additions up to 10,000 square feet where public services and utilities are available, and the area is not considered environmentally sensitive. The proposed project is a 1,140-square-foot addition to an existing single-unit residence in a developed neighborhood and is not within an environmentally sensitive area. 6 Zoning Administrator Resolution No. ZA2024-### Page 2 of 7 08-10-18 3. The exceptions to this categorical exemption under Section 15300.2 are not applicable. The project location does not impact an environmental resource of hazardous or critical concern, does not result in cumulative impacts, does not have a significant effect on the environment due to unusual circumstances, does not damage scenic resources within a state scenic highway, is not a hazardous waste site, and is not identified as a historical resource. SECTION 3. REQUIRED FINDINGS. In accordance with Section 20.52.050(E) (Modification Permits – Required Findings) of the NBMC, the following findings and facts in support of such findings are set forth: Finding: A. The requested modification will be compatible with existing development in the neighborhood. Facts in Support of Finding: 1. The Property was originally developed in 1969 with a 2,508-square-foot, two-story, single-unit residence with an attached 476-square-foot, two-car garage. 2. Development along Port Cardiff Place predominantly consists of two-story, single-unit, residences with some one- and three-story, single-unit residences. There is a Metropolitan Water District facility located approximately 320 feet east of the Property, at the corner of Port Cardiff Place and East Newport Hills Drive. 3. The Project would increase the floor area of the dwelling by 1,140 square feet and add a new bedroom, living room, pantry, and bathroom on the first floor and a new balcony, laundry room, and two bathrooms on the second floor. 4. The areas of addition will not exceed the maximum height allowed by PC 3 and are consistent with the size of other properties in the neighborhood. The proposed addition will comply with all other applicable development standards including lot coverage and setbacks. 5. Although the existing garage depth is nonconforming at 19-feet, 9 inches, the existing garage spaces are adequate to park two vehicles. The substandard depth of the parking spaces would be permissible on a lot 30 feet wide or less, pursuant to Section 20.40.090 (Parking Standards for Residential Uses) of the NBMC, as the minimum depth for a single car space on a lot 30 feet wide or less is 19 feet. Therefore, the existing nonconforming parking spaces are functional for parking purposes and the proposed addition would not create a demand for street parking in the area. 6. The driveway in front of the garage allows for additional onsite parking. Although the driveway parking spaces do not count toward the parking requirement for single-unit dwellings, Section 20.40.090 (Parking Standards for Residential Uses) of the NBMC allows parking of vehicles on driveways within front setback areas that are in front of garages set back a minimum of 20 feet from the front property line. The driveway 7 Zoning Administrator Resolution No. ZA2024-### Page 3 of 7 08-10-18 measures approximately 20 feet wide by 20 feet, 4 inches, deep, which complies with the minimum dimensions of the NBMC. A larger vehicle can use the driveway, which offsets the shorter parking spaces inside the garage. Finding: B. The granting of the modification is necessary due to the unique physical characteristic(s) of the property and/or structure, and/or characteristics of the use. Facts in Support of Finding: 1. The interior dimensions of the garage were compliant with the zoning standards in place at the time of construction. As the result of subsequent amendments to the Zoning Code, the garage is now substandard in size and is considered legal nonconforming. 2. Section 20.38.060 (Nonconforming Parking) of the NBMC limits additions to residential structures with nonconforming parking to a maximum of 10% of the existing floor area within a 10-year period. Subsection (2)(b) however allows for larger additions, subject to the approval of a modification permit. 3. A modification permit is necessary to allow the addition, as expanding the garage is overly difficult and onerous due to the physical characteristics of the existing structure. The proposed addition is located primarily at the front of the Property but does not include any changes to the attached garage. Expanding the garage south towards the front property line or north into the habitable space on the first floor would require new framing and foundations. To reframe the garage and pour additional footings are significant structural alterations which would increase the cost and scope of work of the project while providing negligible benefit. Finding: C. The granting of the modification is necessary due to practical difficulties associated with the property and that the strict application of the Zoning Code results in physical hardships that are inconsistent with the purpose and intent of the Zoning Code. Facts in Support of Finding: 1. PC 3 requires that each single-unit residence provide two parking spaces, in a garage, however it does not provide standards related to the dimensions of the parking spaces. PC 3 defers to the development standards provided within the NBMC, when not otherwise specified. Section 20.40.090 (Parking Standards for Residential Uses) of the NBMC requires the garage provide minimum interior clear dimensions of 20 feet wide by 20 feet deep. 2. The garage provides two useable parking spaces that are only three inches less than the required depth. The existing condition fulfills the intent of the NBMC by providing adequate parking onsite. The Applicant will continue to use the existing two-car garage and park onsite. 8 Zoning Administrator Resolution No. ZA2024-### Page 4 of 7 08-10-18 3. Fact 3 in support of Finding B hereby incorporated by reference. Finding: D. There are no alternatives to the modification permit that could provide similar benefits to the applicant with less potential detriment to surrounding owners and occupants, the neighborhood, or to the general public. Facts in Support of Finding: 1. An alternative to granting the modification permit is to require the garage be brought into compliance with current NBMC standards. While bringing the garage into compliance with current NBMC requirements would provide a negligible benefit, it would require significant alterations to the structure well beyond the scope of the addition. Furthermore, relocating the interior garage wall three inches into the existing habitable space would eliminate habitable space, which is contrary to the purpose of the Project. 2. Given the intent of the Project is to provide a bedroom, living room, pantry, and bathroom on the first floor and a new balcony, laundry room, and two bathrooms on the second floor, reducing the size of the addition to no more than 10% of the existing floor area of the structure as authorized under Section 20.38.060(A) (Nonconforming Parking - Residential) of the NBMC will significantly impact the objectives of the Project and would not provide similar benefits to the Applicant. 3. The Project, as proposed, is not anticipated to cause any detrimental effects to the neighborhood. Finding: E. The granting of the modification would not be detrimental to public health, safety, or welfare, to the occupants of the property, nearby properties, the neighborhood, or the City, or result in a change in density or intensity that would be inconsistent with the provisions of this Zoning Code. Facts in Support of Finding: 1. Although the depth of the parking spaces does not meet the minimum dimensions of the NBMC, the existing garage has sufficient depth to accommodate a typical vehicle and not generate a demand for on-street parking. 2. The proposed two-story addition would maintain all required setbacks and will provide adequate protection for light, air, and privacy. The addition will not preclude access to the residence and will be consistent in scale with other two-story residences in the neighborhood. 3. PC 3 allows for a maximum lot coverage of 60%, which in this case is 3,367 square feet. The proposed lot coverage after the addition is 3,043 square feet or only 48% of the lot area. 9 Zoning Administrator Resolution No. ZA2024-### Page 5 of 7 08-10-18 4. The proposed addition maintains more than the minimum 3-foot side yard for fire access in accordance with Section 20.30.110(A)(1)(c) (Setbacks Regulations and Exceptions) of the NBMC. 5. Fact 6 in support of Finding A hereby incorporated by reference. 6. The approval of this Modification Permit is conditioned such that the applicant is required to obtain all necessary permits in accordance with the Building Code and other applicable Codes. The Building Division has reviewed the proposed project and added conditions of approval for demonstration of project compliance with Building Codes. SECTION 4. DECISION. NOW, THEREFORE, BE IT RESOLVED: 1. The Zoning Administrator of the City of Newport Beach hereby approves PA2024-0187, subject to the conditions set forth in Exhibit A, which is attached hereto and incorporated by reference. 2. This action shall become final and effective 14 days following the date this Resolution was adopted unless within such time an appeal or call for review is filed with the Community Development Director in accordance with the provisions of Title 20 (Planning and Zoning,) of the NBMC. PASSED, APPROVED, AND ADOPTED THIS 12TH DAY OF DECEMBER 2024. _____________________________________ Benjamin M. Zdeba, AICP, Zoning Administrator 10 Zoning Administrator Resolution No. ZA2024-### Page 6 of 7 08-10-18 EXHIBIT “A” CONDITIONS OF APPROVAL (Project-specific conditions are in italics) PLANNING 1. The development shall be in substantial conformance with the approved site plan, floor plans and building elevations stamped and dated with the date of this approval. (Except as modified by applicable conditions of approval.) 2. Each parking space within the garage shall be permanently available and maintained for parking purposes. The interior clear dimensions (20 feet, 10 inches wide by 19 feet, 9 inches deep) shall be kept clear of obstructions including cabinets, shelving, or similar objects that may impact the ability to adequately park two vehicles, except as provided in Section 20.40.090(A)(4) (Parking Standards for Residential Uses) of the NBMC. 3. The Project is subject to all applicable City ordinances, policies, and standards, unless specifically waived or modified by the conditions of approval. 4. The Applicant shall comply with all federal, state, and local laws. Material violation of any of those laws in connection with the use may be cause for revocation of this Modification Permit. 5. Demolition beyond the approved scope of work requires Planning Division approval prior to commencement of work. Approval of revisions to project plans are not guaranteed and may require the garage to be redeveloped in conformance with the current NBMC development standards. 6. A copy of the Resolution, including conditions of approval Exhibit “A” shall be incorporated into the Building Division and field sets of plans prior to issuance of the building permits. 7. Should the Property be sold or otherwise come under different ownership, any future owners or assignees shall be notified of the conditions of this approval by either the current business owner, Property owner or the leasing agent. 8. This approval shall expire and become void unless exercised within 24 months from the actual date of review by authority approval, except where an extension of time is approved in compliance with the provisions of Title 20 (Planning and Zoning) of the NBMC. 9. To the fullest extent permitted by law, applicant shall indemnify, defend and hold harmless the City, its City Council, its boards and commissions, officials, officers, employees, and agents from and against any and all claims, demands, obligations, damages, actions, causes of action, suits, losses, judgments, fines, penalties, liabilities, costs and expenses (including without limitation, attorney’s fees, disbursements and court costs) of every kind and nature whatsoever which may arise from or in any manner relate (directly or indirectly) to City’s approval of the Tang Residence including, but not limited to, the Modification Permit filed as PA2024-0187. This indemnification shall include, but not be limited to, 11 Zoning Administrator Resolution No. ZA2024-### Page 7 of 7 08-10-18 damages awarded against the City, if any, costs of suit, attorneys' fees, and other expenses incurred in connection with such claim, action, causes of action, suit or proceeding whether incurred by applicant, City, and/or the parties initiating or bringing such proceeding. The applicant shall indemnify the City for all of City's costs, attorneys' fees, and damages which City incurs in enforcing the indemnification provisions set forth in this condition. The applicant shall pay to the City upon demand any amount owed to the City pursuant to the indemnification requirements prescribed in this condition. Building Division Conditions 10. Prior to permit issuance, plans shall be updated to provide an emergency escape and rescue opening in the master bedroom sufficient to satisfy applicable California Building Code requirements. Fire Department Conditions 11. Prior to permit issuance, plans shall be updated to show a residential fire sprinkler system throughout the residence and garage sufficient to satisfy applicable California Fire Code requirements. Public Works Department Conditions 12. Prior to permit issuance, plans shall be updated to demonstrate compliance with the following: a) The installation a new sewer cleanout on the existing sewer lateral pursuant to City Standard 406. The sewer clean out shall be installed within the sidewalk area in the public right of way; b) The reconstruction of the damaged driveway pursuant to City Standard 162; and c) The removal of the existing basketball hoop structure from the public right of way. 12 Attachment No. ZA 2 Vicinity Map 13 VICINITY MAP Modification Permit (PA2024-0187) 1935 Port Cardiff Place Subject Property Subject Property 14 Attachment No. ZA 3 Project Plans 15 1ST FLOOR (E) BUILDING TOTAL LOT AREA : 6,367 SQ.FT MAX. SITE COVERAGE: 3,820 SQ.FT (60% OF LOT AREA) (E) 2-CAR GARAGE (N) ADDITION 2ND FLOOR TOTAL 476.00 230.00 910.11 1,140.11 2,508.001,782.00 726.00 COVER AREA TOTAL AREA TOTALLOT COVER AREA 3,043.00 (LOT COVERAGE : 47.79 %) 555.00(PORCH, BALCONY,EAVE) -476.00 555.00 3,043.00 1,951.11 4,679.11 [ TOTAL 1ST FLOOR AREA + EAVE + GARAGE] - ZONING : PROJECT ADDRESS : PARCEL NUMBER : 1935 PORT CARDIFF PLACE, SCOPE OF WORK : OWNER : TYPE OF CONSTRUCTION : LOT AREA : TYPE - VB PROJECT INFORMATION NUMBER OF STORY :2-STORY APPLICABLE STATE CODES SHEET INDEX 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE CS-101 COVER PAGE CS-102 RENDERINGSP-101 SITE PLAN A-100 EXISTING FLOOR PLAN A-101 PROPOSED 1ST FLOOR PLAN A-101.1 PROPOSED 2ND FLOOR PLAN A-101.2 WINDOW SCHEDULE & NOTEA-301 EXISTING ELEVATION-1 A-302 EXISTING ELEVATION-2 A-303 PROPOSED ELEVATION-1A-304 PROPOSED ELEVATION-2 AD-401 TYP. DETAIL AD-402 FIREPLACE SPECIFICATION ARCHITECTURAL VICINITY MAP CITY APPROVAL STAMP 9630 ALONDRA BLVD. STE ABELLFLOWER, CA 90706 DESIGN STUDIO META 213.232.1604 DANIEL LEE Info@dsmeta.com PHONE ADDRESS CONTACT FAX E-MAIL: 213.568.7777 PHONE ADDRESS CONTACT FAX E-MAIL: STRUCTURAL ENGINEER PROJECT DIRECTORY CS-101 COVER PAGE JOHN TANG NEWPORT BEACH, CA 92660 45809208 PC-3 AREA3 6,367 SQ.FT (E) BUILDING :2,508 SQ.FT HWANG STRUCTURAL ENGINEERS INC. 3501 OCEAN VIEW BLVD.GLENDALE, CA 91208 JUNO HWANG juno@hwangse.com 213.268.0935 TANG'S RESIDENCE 1935 PORT CARDIFF PLACE, NEWPORT BEACH, CA 92660 AREA ANALYSIS N JOB SITE DRAWING NO. SCALE: 19 3 5 P O R T C A R D I F F P L A C E , DRAWING TITLE ISSUE RECORD NO. DESCRIPTION DATE ds Meta PROJECT NO. DESIGN STUIDO META, INC. 9630 ALONDRA BLVDBELLFLOWER, CA 90706 DIRECT : +1.213.703.0243OFFICE : +1.213.568.7777 www.dsmeta.com PACKAGE TITLE PROJECT STRUCTURAL ENGINEER MECH/ELECT/PLUMB ENGINEER ARE AND SHALL REMAIN THE PROPERTY THE DRAWINGS AND SPECIFICATIONS, ALL PRODUCTION & INTELLECTUAL NO PART THEREOF SHALL BE COPIED OROF THE DESIGN STUDIO META INC.; USED IN CONNECTION WITH ANY WORK PROJECT FOR WHICH THEY HAVE BEEN OR PROJECT OTHER THAN THE SPECIFIC CONSENT OF DESIGN STUDIO META INC. PREPARED WITHOUT THE WRITTEN IDEAS, DESIGNS, AND ARRANGEMENTS VISUAL CONTACT WITH THERE DRAWINGS EVIDENCE OF ACCEPTANCE OF THEREOR SPECIFICATION SHALL CONSTITUTE RESTRICTIONS. PROPERTY RIGHTS RESERVED PRELIMINARY PLAN 223-05-160 TA N G ' S R E S I D E N C E 01 1ST BLDG SUBMIT 09/06/2023 NE W P O R T B E A C H , C A 9 2 6 6 0 02 2ND HOA SUBMIT 12/26/2023 03 2ND BLDG SUBMIT 05/10/20241 04 3RD BLDG SUBMIT 07/11/20242 05 MODIFICATION SUBMIT 07/11/2024 MECHANICAL & PLUMBING ENGINEER PHONE: ADDRESS: CONTACT: JT ENGINEERING. INC 13405 ARTESIA BLVD. #201-JCERRITOS, CA 90703 213-389-7886 SUNNY XU sunny@jtengineer.comE-MAIL: OCCUPANCY GROUP : R3/U FIRE SPRINKLER :YES (UNDER SEPARATE PERMIT) STORM WATER-BEST MANAGEMENT PRACTICES 1. AN WET WEATHER EROSION CONTROL PLAN (WWECP) UTILIZING SEDIMENT AND EROSION CONTROL BMWS, FOR PROJECTS THAT WILL LEAVE DISTURB SOIL DURING THE RAINY SEASON (OCTOBER 1 TO APRIL 15) IS REQUIRED. THE WWECP MUST BE PREPARED, FOR PROJECTS THAT HAVE ALREADY BROKEN THE VEST MANAGEMENT PRACTICES (BMP) IDENTIFIED ON GROUND, NOT LESS THAN 30 DAYS PRIOR TO THE BEGINNING OF EACH RAINY SEASON DURING THE WHICH SOIL WILL BE DISTURBED, AND IMPLEMENTED THROUGHOUT THE ENTIRE RAINY SEASON. A COPY OF THE WWECP SHALL BE KEPT ON THE PROJECT SITE AT ALL TIMES BEGINNING 30 DAYS PRIOR TO THE START OF THE RAINY SEASON THROUGH THE END OF THE RAINY SEASON. FOR PROJECTS THAT WILL BEGIN CONSTRUCTION DURING THE RAINY SEASON, THE WWECP MUST BE AVAILABLE 30 DAYS BEFORE CONSTRUCTION COMMENCES. THE WWECP MUST BE SUBMITTED TO THE BUREAU OF ENGINEERING, PUBLIC WORKS FOR REVIEW AND APPROVAL. THE WWECP IS NOT A REQUIREMENT FOR THE ISSUANCE OF BUILDING OR GRADING PERMIT. a. CONSTRUCTION PROJECTS-SMALL CONSTRUCTION SITES WITH LESS THAN TWO ACRES OF DISTURBED SOIL AND NOT LOCATED IN DESIGNATED HILLSIDE AREAS NOR IN OR ADJACENT TO AN ENVIRONMENTAL SENSITIVE AREAS SHALL IMPLEMENT THE BEST MANAGEMENT "A" ENTITLED "MINIMUM REQUIREMENTS FOR CONSTRUCTION PROJECTS/ CERTIFICATION STATEMENT". IN ADDITION. IN ACCORDANCE WITH THE FOLLOWING REQUIREMENT OF EXCEPTION 14,SECTION 106.4.1. 2. PROVIDE RAIN GUTTERS AND CONVEY RAIN WATER TO STREET. 3. IF ADVERSE SOIL CONDITIONS ARE ENCOUNTERED, A SOILS INVESTIGATION REPORT MAY BE REQUIRED. 4. A GRADING BOND IS REQUIRED TO BE POSTED FOR PROJECTS INVOLVING OVER 250 CUBIC YARDS OF SOIL IN "HILLSIDE GRADING AREAS". 5. AN APPROVED SEISMIC GAS SHUTOFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE ON THE DOWN STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING." (PER ORDINANCE 170,158) (INCLUDES COMMERCIAL ADDITIONS AND TI WORK OVER 10,000.) SEPARATE PLUMBING PERMIT IS REQUIRED. 6. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOTGEAR AND UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL-BOXES, TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ETC.) OR TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES-WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES. 7. PROVIDE ULTRA FLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING SHOWER HEADS AND TOILETS MUST BE ADAPTED FOR LOW WATER CONSUMPTION. 8. PROVIDE 70 INCH HIGH NON-ABSORBENT WALL ADJACENT TO SHOWER AND APPROVED SHATTER-RESISTANT MATERIALS FOR SHOWER ENCLOSURE.(1115B.2 AND 2406.3(5) 1. THESE DRAWINGS ARE PROVIDED BY THE DESIGN TEAM TO THE OWNER WHO WILL BE WORKING CLOSELY WITH A BUILDER AND ARE LIMITED IN SCOPE. 2. THE OWNER AND BUILDER ARE RESPONSIBLE FOR ALL PORTIONS OF THE DESIGN SPECIFICALLY NOT CALLED FOR IN THESE DRAWINGS AND FOR OBSERVATION AND ADMINISTRATION OF THE CONSTRUCTION CONTRACT. 3. THE OWNER AND BUILDER ARE RESPONSIBLE FOR ANY COORDINATION AND OR MODIFICATIONS NECESSARY TO MEET ANY OF THE REQUIRED GOVERNMENT AGENCIES HAVING ANY JURISDICTION OVER ANY PORTION OF THIS PROJECT. 4. THE WORK OF AY DESIGN PROFESSIONALS AND OR SUBCONTRACTORS WHICH ARE OR SHOULD BE INVOLVED IN THIS PROJECT SHALL FOLLOW GOOD CONSTRUCTION PRACTICES. 5. GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF ALL WORK WITH ALL TRADES INVOLVED. 6. THESE DRAWINGS REPRESENT FIELD MEASUREMENTS AND DO NOT FULLY REFLECT EXISTING CONDITIONS, GENERAL CONTRACTOR SHALL VERIFY ALL ELEVATIONS, DIMENSIONS, AND LOCATIONS OF EXISTING FEATURES BEFORE STARTING WORK OF ORDERING MATERIALS, NOTIFY DESIGN TEAM OF ANY DISCREPANCIES. 7. DRAWINGS INDICATE INTENDED AND INFERRED SCOPE OF WORK CONTRACTOR SHALL PROVIDE ALL NECESSARY ROUGH PLUMBING, WIRING, CARPENTRY, ETC. INCLUDING MODIFICATION OF EXISTING CONDITIONS TO COMPLETE THE ENTIRE SCOPE OF WORK. 8. CONTRACTOR SHALL COMPLETE WORK IN ACCORDANCE WITH INDUSTRY AND MANUFACTURES WRITTEN REQUIREMENTS. FINISH WORK TO BE COMPLETED IN A PROFESSIONAL QUALITY MANNER. 9. DRAWINGS, SECTIONS, AND DETAILS REPRESENT TYPICAL CONDITIONS, THE CONTRACTOR IS TO REVIEW WITH THE DESIGN TEAM OF NON TYPICAL CONDITIONS THAT REQUIRE A MODIFICATION TO THE DESIGN. 10. REFERENCES TO SPECIFIC MANUFACTURES PRODUCTS ON THE DRAWING ESTABLISH A STANDARD OF QUALITY, PRODUCTS THAT ARE APPROVED AS EQUAL BY THE DESIGN TEAM ARE ACCEPTABLE. 11. REFERENCES TO SPECIFIC MANUFACTURES PRODUCTS ON THE DRAWINGS ESTABLISH A STANDARD OF QUALITY, PRODUCTS THAT ARE APPROVED AS EQUAL BY THE DESIGN TEAM ARE ACCEPTABLE. 12. CONTRACTOR SHALL SUBMIT TO OWNER AND DESIGN TEAM SAMPLES OF ALL FINISH MATERIALS FOR APPROVAL OF COLOR, STYLE, AND TEXTURE, PRIOR TO FABRICATION AND OR INSTALLATION. 13. CONTRACTOR SHALL REMOVE FROM SITE AND DISCARD ALL CONSTRUCTION DEBRIS AT APPROVED DISPOSAL SITE. 14. NO SMOKING IS TO BE ALLOWED ON THE CONSTRUCTION SITE AT ANY TIME. 15. CONTRACTOR SHALL LIMIT USE OF PROMISED TO THE WORK INDICATED OR INFERRED. 16. CONTRACTOR SHALL ENSURE SAFE PASSAGE OF PERSONS AROUND AREA OF CONSTRUCTION. PROVIDED TEMPORARY BARRICADES TO PROTECT THE GENERAL PUBLIC FROM INJURY DUE TO CONSTRUCTION WORK. 17. INTERIOR FINISHES IN EXIT ACCESS AREAS TO BE CLASS A, CLASS B IN OTHERS. CONTRACTOR TO VERIFY ALL EXITS MEET CURRENT BUILDING AND SAFETY CODES. 18. INSULATION SHALL HAVE A SMOKE DEVELOPED RATING OF 450 MAX.CONCEALED INHALATION SHALL HAVE A FLAME SPREAD RATING OF 75 MAX., AND EXPOSED INSULATION SHALL HAVE A FLAME SPREAD RATING OF 25MAX. 19. CONTRACTOR RESPONSIBLE AND SHALL MAINTAIN EXISTING AND NEW STRUCTURES WATER TIGHT INTEGRITY TROUGH USE OF TARPS AND OR PERMANENT MODIFICATIONS DURING CONSTRUCTION. 20. CONTRACTOR TO PARK IN DESIGNATED AREA ONLY. 21. DUMPSTER LOCATION TO BE DETERMINED BY PROJECT TEAM. 22. ALL CONSTRUCTION ACTIVITIES OR MOVEMENT TO OCCUR ON OR LIMITED TO OWNERS PROPERTY. 23. THESE DRAWINGS CAN NOT STAND ALONE AS CONSTRUCTION DOCUMENTS. 24. DOOR OPENING ARE TO BE SET 6" AWAY FROM INTERSECTING WALLS UNLESS OTHERWISE SPECIFIED. 25. SEE STRUCTURAL ENGINEERING DRAWINGS FOR STRUCTURAL CONNECTION TECHNIQUES, CALCULATIONS REQUIRED BY CODE COMPLIANCE INSTRUCTIONS FOR WALL AND ROOF CONSTRUCTION AND THE TIE DOWN REQUIREMENTS. 26. SEPARATE MECHANICAL ELECTRICAL AND PLUMBING ENGINEERING DOCUMENTS MAY BE PROVIDED WHICH INDICATE REQUIRED SERVICE AND RISER DIAGRAMS CALCULATIONS AND INSTALLATION SPECIFICATIONS BEYOND THE DESIGN TEAMS BASIC LAYOUT AND SELECTIONS SUGGESTED. 27. SEPARATE CIVIL ENGINEERING DOCUMENTS MAY BE PROVIDED WHICH INDICATE ADDITIONAL SITE PLANNING DRAINAGE AND OTHER RELATED SITE WORK REQUIREMENTS. 28. SELECTIONS NOT INCLUDED IN THESE DOCUMENTS WILL BE COORDINATED BY THE OWNERS REPRESENTATIVE. GENERAL NOTES 29. BY APPLYING FOR A BUILDING PERMIT AND OR CONSTRUCTING THE PROJECT REPRESENTED HEREIN THE OWNER AGREES TO LIMIT THE LIABILITY OF THE DESIGN TEAM TO THE OWNER OF THE PROJECT FOR ALL CLAIMS LOSSES DAMAGES OR AMY NATURE WHATSOEVER OR CLAIMS OF EXPENSES FOR ANY SUCH ITEMS TO THE DESIGN TEAMS TOTAL COMPENSATION FOR SERVICES RENDERED HEREIN. 30. FOR DIMENSIONS NOT SHOWN OR IN QUESTION THE CONTRACTOR MUST REQUEST IN WRITING THE CLARIFICATION FROM THE DESIGN TEAM BEFORE PROCEEDING. 31. CONTRACTOR WILL VERITY ALL EXISTING CONDITIONS IN THE FIELD ANY DISCREPANCIES WILL BE BROUGHT TO THE ATTENTION OF THE DESIGN TEAM. 32. INFORMATION CONTAINED ON THESE DRAWINGS IS PROVIDED FOR THE CONVENIENCE OF THE GENERAL CONTRACTOR IN EXECUTING THE WORK EVERY ATTEMPT HAS BEEN MADE TO PROVIDE A COMPLETE AND ACCURATE REPRESENTATION OF SUCH CONDITIONS. 33. WHEN THE DESIGN TEAMS DRAWINGS ARE IN CONFLICT WITH THE ENGINEERING AND CONSULTANTS DRAWINGS THE GENERAL CONTRACTOR MUST REQUEST IN WRITING CLARIFICATION FROM THE DESIGN TEAM BEFORE PROCEEDING WITH ANY CONSTRICTION. 1. ALL ENTRY DOORS TO DWELLING UNITS OR GUEST ROOMS SHALL BE ARRANGED SO THAT THE OCCUPANT HAS A VIEW OF THE AREA IMMEDIATELY OUTSIDE OF THE DOOR WITHOUT OPENING THE DOOR. SUCH VIEW MAY BE PROVIDED BY A DOOR VIEWER, THOUGH WINDOWS LOCATED IN THE VICINITY OF THE DOOR OR THROUGH VIEW PORTS IN THE DOOR OR ADJOINING WALL. 2. WOOD FLUSH-TYPE DOORS SHALL BE 1 3/8" THICK MIN. W/SOLID CORE CONSTRUCTION. 91.6709.1- DOOR STOPS OF IN-SWINGING DOORS SHALL BE OF ONE-PIECE CONSTRUCTION W/THE JAMB OR JOINED BY RABBET TO THE JAMB. 3. ALL PIN-TYPE DOOR HINGES ACCESSIBLE FROM OUTSIDE SHALL HAVE NON-REMOVABLE HINGE PINS. HINGES SHALL HAVE MIN. 1/4" DIA. STEEL JAMB STUD WITH 1/4" MIN. PROTECTION. THE STRIKE PLATE FOR LATCHES AND HOLDING DEVICE PROJECTING DEAD BOLTS IN WOOD CONSTRUCTION SHALL BE SECURED TO THE JAMB AND THE WALL FRAMING WITH SCREWS NO LESS THAN 2/12" LONG. 4. PROVIDE DEAD BOLTS WITH HARDENED INSERTS: DEADLOCKING LATCH WITH KEY-OPERATED LOCKS ON EXTERIOR. LOCKS MUST BE OPERABLE FROM INSIDE WITHOUT KEY, SPECIAL KNOWLEDGE OR SPECIAL EFFORT (LATCH NOT REQUIRED IN B,F, AND S OCCUPANCIES.) 5. STRAIGHT DEAD BOLTS SHALL HAVE A MIN. THROW OF 1" AND AN EMBODIMENT OF NOT LESS THAN 5/8", AND A HOOK-SHAPED OR AN EXPANDING-RUG DEADBEAT SHALL HAVE A MIN. THROW OF 3/4". 6. THE USE OF A LOCKING SYSTEM WHICH CONSISTS OF A DEADLOCKING LATCH OPERATED BY A DOORKNOB AND DEADBOLT OPERATED BY A NON-REMOVABLE THUMB THRN WHICH IS INDEPENDENT OF THE DEADLOCKING LATCH AND WHICH MUST BE SEPARATELY OPERATED, SHALL NOT BE CONSIDERED AS A SYSTEM WHICH REQUIRES SPECIAL KNOWLEDGE OR EFFORT WHEN USED IN DWELLING UNITS. THE DOOR KNOB AND THE THUMB TURN WHICH OPERATES THE DEADBOLT SHALL NOT BE SEPARATED BY MORE THAN 8". 7. SLIDING DOOR SHALL BE PROVIDED WITH A DEVICE IN THE UPPER CHANNEL OF THE MOVING PANEL TO PROHIBIT RAISING AND REMOVING OF THE MOVING PANEL IN THE CLOSED OR PARTIALLY OPEN POSITION. 8. SLIDING GLASS DOORS SHALL BE EQUIPPED WITH LOCKING DEVICES AND SHALL BE SO CONSTRUCTED AND INSTALLED THAT THEY REMAIN INTACT AND ENGAGED WHEN SUBJECTED TO THE TESTS SPECIFIED IN SEC. 6717.1 WINDOWS: 1. SLIDING WINDOW SHALL BE PROVIDED WITH A DEVICE IN THE SCUPPER CHANNEL OF THE MOVING PANEL TO PROHIBIT RAISING AND REMOVING OF THE MOVING PANEL IN THE CLOSED OR PARTIALLY OPEN POSITION. 2. SLIDING WINDOWS SHALL BE EQUIPPED WITH LOCKING DEVICESAND SHALL BE SO CONSTRUCTED AND INSTALLED THAT THEY REMAIN INTACT AND ENGAGED WHEN SUBJECTED TO THE TESTS SPECIFIED IN SEC. 6717.2 SECURITY REQUIREMENTS SITE PLAN NOTES DEFERRED SUBMITTAL : SOUND ATTENUATION DESIGN FOR HVAC, FIRE SPRINKLER, ENCROACHMENT PERMIT * DEFERRED SUBMITTALS TO BE REVIEWED BY PROJECT ARCHITECT ORENGINEER OF RECORD AND CERTIFIED PRIOR TO SUBNITTAL FOR PLAN CHECKOR APPROVAL BY THE CITY. , PUBLIC WORK * OBTAIN FIRE SPRINKLER PERMIT PRIOR TO CALLING FOR ROOF SHEATHING 1) 2-STORY SFD. ADDITION OF 1,140.11 SF2) PARTIAL INTERIOR REMODELING OF 2,250 SF * NO LANDSCAPE WOKRS 16 CS-102 RENDERING DRAWING NO. SCALE: 19 3 5 P O R T C A R D I F F P L A C E , DRAWING TITLE ISSUE RECORD NO. DESCRIPTION DATE ds Meta PROJECT NO. DESIGN STUIDO META, INC. 9630 ALONDRA BLVDBELLFLOWER, CA 90706 DIRECT : +1.213.703.0243OFFICE : +1.213.568.7777 www.dsmeta.com PACKAGE TITLE PROJECT STRUCTURAL ENGINEER MECH/ELECT/PLUMB ENGINEER ARE AND SHALL REMAIN THE PROPERTY THE DRAWINGS AND SPECIFICATIONS, ALL PRODUCTION & INTELLECTUAL NO PART THEREOF SHALL BE COPIED OROF THE DESIGN STUDIO META INC.; USED IN CONNECTION WITH ANY WORK PROJECT FOR WHICH THEY HAVE BEEN OR PROJECT OTHER THAN THE SPECIFIC CONSENT OF DESIGN STUDIO META INC. PREPARED WITHOUT THE WRITTEN IDEAS, DESIGNS, AND ARRANGEMENTS VISUAL CONTACT WITH THERE DRAWINGS EVIDENCE OF ACCEPTANCE OF THEREOR SPECIFICATION SHALL CONSTITUTE RESTRICTIONS. PROPERTY RIGHTS RESERVED PRELIMINARY PLAN 223-05-160 TA N G ' S R E S I D E N C E 01 1ST BLDG SUBMIT 09/06/2023 NE W P O R T B E A C H , C A 9 2 6 6 0 02 2ND HOA SUBMIT 12/26/2023 03 2ND BLDG SUBMIT 05/10/20241 04 3RD BLDG SUBMIT 07/11/20242 05 MODIFICATION SUBMIT 07/11/2024 1 EXISTING EXTERIOR 2 PROPOSED EXTERIOR FRONT VIEW REAR VIEWREAR VIEW FRONT VIEW 17 (E) POOL UP (E) 2 CAR GARAGE (E)FIRE PLACE (E) 2 STORY HOUSE (E) B.B.Q STATION (E) FIRE PLACE (E) STORAGE (E) 2-STEP STAIR 5'-9"(E)SETBACK (E) DRIVE WAY (E) LAWN (E) LAWN (E) LAWN DN (E) LAWN (E) LANDSCAPE (E) CONC. PAVING (E) CONC.PAVING (E ) S L O P E 2% M I N 2,508 SQ.FT PL 65'-0" PL 9 8 ' - 0 " PL 65'-0" PL 9 8 ' - 0 " 476 SQ.FT V.I.F 9'-8"(E)SETBACK V.I.F 20 ' - 4 " ( E ) S E T B A C K 34 ' - 1 0 " ( E ) S E T B A C K V.I . F V. I . F (E) DRIVE WAY APPROACH (E) STORAGE 49'-7" 45 ' - 0 " 22'-8" 13 ' - 5 " 27'-1" 28 ' - 0 " PORT CARDIFF PL. 15'-9" 21'-0" 2'-3" 12"x18" WATER METER 16'-3" Ø4" TRUNK TREE PROTECT IN PLACE PROTECT IN PLACE 6" 5'- 4 " 4'- 0 " 6" CF 9'-2" (E) SIDEWALK 9'-1 0 " 2'-8"2'-8" 2'- 0 " (E) TRASHAREA (E) POOLEQUIPMENT (E) A/C (E ) S L O P E 2% M I N (E) POOL (E) 2 CAR GARAGE (E) 2 STORY HOUSE (E) B.B.Q STATION (E) FIRE PLACE (E) STORAGE (E ) S L O P E 2% M I N 5'-9" (E)SETBACK 9'-8"(E)SETBACK (E) DRIVE WAY (E) LAWN (E) LAWN (E) LAWN DN (E) LAWN (E ) S L O P E 2% M I N 20 ' - 4 " ( E ) S E T B A C K 476 SQ.FT UP (N) PORCH (N) 2STORY ADDITION 1,140.11 SQ.FT PL 65'-0" PL 9 8 ' - 0 " PL 65'-0" PL 9 8 ' - 0 " 34 ' - 1 0 " ( E ) S E T B A C K V.I . F V.I.F V.I.F V.I . F UP (N) DECK PORT CARDIFF PL. (N) DRIVE WAY APPROACH (E ) S L O P E 2% M I N 49'-7" 45 ' - 4 " 22'-7" 40 ' - 7 " 7'- 3 " 27'-1" 15'-9" 2'-3" 16'-3" 29'-0" INSTALL A NEW SEWER CLEAN OUT ON THE EXISTING SEWER LATERAL PER CITY STANDARD 406 21'-8"9'-7"3'-0"3'-0" REPLACE THE EXISTING DAMAGED DRIVEWAY PER CITY STANDARD 162 12"x18" WATER METER Ø4" TRUNK TREE PROTECT IN PLACE PROTECT IN PLACE (E) SIDEWALK EAVE LINE EAVE LINE 1'-9" 1'-9" 1'- 9 " 9" 6" 1'- 0 " 6'- 3 " REMOVE BASKETBALL HOOPFROM RIGHT-OF-WAY (E) 6'H WOODFENCE V.I.F 6" 5'- 4 " 4'- 0 " 6" CF 9'- 1 0 " 2'-0 " 32 ' - 6 " PR O J E C T I O N D I M (E) TRASHAREA (E) POOL EQUIPMENT (N) A/C (N) A/C EAVE LINE EAVE LINE EAVELINE EAVE LINE UNDER SEPARATE PERMIT (E ) S L O P E 2% M I N SP-1011PROPOSED SITE PLAN SITE PLAN 2 EXISTING SITE PLAN N DRAWING NO. SCALE: 19 3 5 P O R T C A R D I F F P L A C E , DRAWING TITLE ISSUE RECORD NO. DESCRIPTION DATE ds Meta PROJECT NO. DESIGN STUIDO META, INC. 9630 ALONDRA BLVDBELLFLOWER, CA 90706 DIRECT : +1.213.703.0243OFFICE : +1.213.568.7777 www.dsmeta.com PACKAGE TITLE PROJECT STRUCTURAL ENGINEER MECH/ELECT/PLUMB ENGINEER ARE AND SHALL REMAIN THE PROPERTY THE DRAWINGS AND SPECIFICATIONS, ALL PRODUCTION & INTELLECTUAL NO PART THEREOF SHALL BE COPIED OROF THE DESIGN STUDIO META INC.; USED IN CONNECTION WITH ANY WORK PROJECT FOR WHICH THEY HAVE BEEN OR PROJECT OTHER THAN THE SPECIFIC CONSENT OF DESIGN STUDIO META INC. PREPARED WITHOUT THE WRITTEN IDEAS, DESIGNS, AND ARRANGEMENTS VISUAL CONTACT WITH THERE DRAWINGS EVIDENCE OF ACCEPTANCE OF THEREOR SPECIFICATION SHALL CONSTITUTE RESTRICTIONS. PROPERTY RIGHTS RESERVED PRELIMINARY PLAN 223-05-160 TA N G ' S R E S I D E N C E 01 1ST BLDG SUBMIT 09/06/2023 NE W P O R T B E A C H , C A 9 2 6 6 0 02 2ND HOA SUBMIT 12/26/2023 03 2ND BLDG SUBMIT 05/10/20241 04 3RD BLDG SUBMIT 07/11/20242 05 MODIFICATION SUBMIT 07/11/2024 N SCALE : 3/16" = 1'-0"SCALE : 3/16" = 1'-0" 18 (E) WALL (E) DEMO (N) WALL (N) PONY WALL UP DN FIX W I N REF. FIX WIN F/P D/W BENCH BEN C H S/T (E) KITCHEN (E) LIVING ROOM (E) 2 CAR GARAGE (E) DINNING ROOM (E) FAMILY ROOM A 1 2 3 4 5 B C D E $ (E) BATH W/H A/C TERRACE CLOSET CLOSET DN CLOSET CLOSET CLOSET (E) MASTER BATHROOM(E) MASTER BEDROOM (E) BATHROOM (E) BEDROOM (E) BEDROOM (E) BEDROOM UP A 1 2 3 4 5 B C D E $ TUB (E) WALL (E) DEMO (N) WALL (N) PONY WALL DRAWING NO. SCALE: 19 3 5 P O R T C A R D I F F P L A C E , DRAWING TITLE ISSUE RECORD NO. DESCRIPTION DATE ds Meta PROJECT NO. DESIGN STUIDO META, INC. 9630 ALONDRA BLVDBELLFLOWER, CA 90706 DIRECT : +1.213.703.0243OFFICE : +1.213.568.7777 www.dsmeta.com PACKAGE TITLE PROJECT STRUCTURAL ENGINEER MECH/ELECT/PLUMB ENGINEER ARE AND SHALL REMAIN THE PROPERTY THE DRAWINGS AND SPECIFICATIONS, ALL PRODUCTION & INTELLECTUAL NO PART THEREOF SHALL BE COPIED OROF THE DESIGN STUDIO META INC.; USED IN CONNECTION WITH ANY WORK PROJECT FOR WHICH THEY HAVE BEEN OR PROJECT OTHER THAN THE SPECIFIC CONSENT OF DESIGN STUDIO META INC. PREPARED WITHOUT THE WRITTEN IDEAS, DESIGNS, AND ARRANGEMENTS VISUAL CONTACT WITH THERE DRAWINGS EVIDENCE OF ACCEPTANCE OF THEREOR SPECIFICATION SHALL CONSTITUTE RESTRICTIONS. PROPERTY RIGHTS RESERVED PRELIMINARY PLAN 223-05-160 TA N G ' S R E S I D E N C E 01 1ST BLDG SUBMIT 09/06/2023 NE W P O R T B E A C H , C A 9 2 6 6 0 02 2ND HOA SUBMIT 12/26/2023 03 2ND BLDG SUBMIT 05/10/20241 04 3RD BLDG SUBMIT 07/11/20242 05 MODIFICATION SUBMIT 07/11/2024 A-1002EXISTING 2ND FLOOR PLAN1EXISTING 1ST FLOOR PLAN EXISTINGFLOOR PLAN SCALE : 1/4"=1'-0"SCALE : 1/4"=1'-0" N N 19 5'-9 " (E ) S E T B A C K 9'- 8 " (E ) S E T B A C K (E) DRIVE WAY (E) LAWN 20'-4" (E) SETBACK PL 6 5 ' - 0 " PL 98'-0" PL 6 5 ' - 0 " PL 98'-0" 34'-10" (E) SETBACK V.I.F V.I . F V.I. F V.I.F UP PO R T C A R D I F F P L . (N) A/C LIN E A B O V E (N) FIREPLACE UP DN REF. D/W W/H BIM 1 7 X 8 S/T (E) KITCHEN (N) LIVING ROOM (E) GARAGE (E) FAMILY ROOM SHOWER (N) BEDROOM 3 (N)MUD CABINET (N)ISLAND CLOSET(N)PANTRY LIN E A B O V E    (E) POWDERROOM W/H DN WOOD DECK (N) SLOPE2% MIN 24"x24" UNDER FLOORSPACES ACCESS 24x30 CLR (N) BATHROOM 3 - ESR: 1667 (N) COMPOSITE 45'-1" 18'-0"5'-4"19'-9" 49' - 3 " 21 ' - 8 " 20 ' - 9 3 / 4 " 40'-7" 12'-6" 49' - 3 " 16 ' - 7 " 21 ' - 2 " 5'-4" 3'-6" 3'- 5 " 15'-9" 4'-10" 8'-9 " 3'- 1 0 " 5'- 9 " 5'-0" 10 ' - 0 " 7'-3" 5'-0" 5'-6" $    $ $    D3 D2D2 W04W02W03W01W01 D1 7 3/4"6"7 1/2" W14 D5 D6 W13 W13 W13W13D3 7 1/2"D7 D9 D2 D2 3'- 0 " D10 1'- 0 " 1'- 0 " 2'- 0 " 5'-5" 19'-9" 20 ' - 1 0 " 21 ' - 8 " 18'-4" 1 1/4"36x 3 6 2'-10" 3'- 8 1 / 4 " $' 1'-3" 2'-9" MAX7 3/4" MAX A 1 2 3 4 5 BCDE (N) SLOPE2% MIN (E) WALL (E) DEMO (N) WALL (N) PONY WALL A-1011PROPOSED 1ST FLOOR PLAN PROPOSED1ST FLOOR DRAWING NO. SCALE: 19 3 5 P O R T C A R D I F F P L A C E , DRAWING TITLE ISSUE RECORD NO. DESCRIPTION DATE ds Meta PROJECT NO. DESIGN STUIDO META, INC. 9630 ALONDRA BLVDBELLFLOWER, CA 90706 DIRECT : +1.213.703.0243OFFICE : +1.213.568.7777 www.dsmeta.com PACKAGE TITLE PROJECT STRUCTURAL ENGINEER MECH/ELECT/PLUMB ENGINEER ARE AND SHALL REMAIN THE PROPERTY THE DRAWINGS AND SPECIFICATIONS, ALL PRODUCTION & INTELLECTUAL NO PART THEREOF SHALL BE COPIED OROF THE DESIGN STUDIO META INC.; USED IN CONNECTION WITH ANY WORK PROJECT FOR WHICH THEY HAVE BEEN OR PROJECT OTHER THAN THE SPECIFIC CONSENT OF DESIGN STUDIO META INC. PREPARED WITHOUT THE WRITTEN IDEAS, DESIGNS, AND ARRANGEMENTS VISUAL CONTACT WITH THERE DRAWINGS EVIDENCE OF ACCEPTANCE OF THEREOR SPECIFICATION SHALL CONSTITUTE RESTRICTIONS. PROPERTY RIGHTS RESERVED PRELIMINARY PLAN 223-05-160 TA N G ' S R E S I D E N C E 01 1ST BLDG SUBMIT 09/06/2023 NE W P O R T B E A C H , C A 9 2 6 6 0 02 2ND HOA SUBMIT 12/26/2023 03 2ND BLDG SUBMIT 05/10/20241 04 3RD BLDG SUBMIT 07/11/20242 05 MODIFICATION SUBMIT 07/11/2024 N SCALE : 1/4" = 1'-0" 2 AD4018,11 AD40110 AD4013 AD40110 AD40113 2 20 D W (N) BALCONY DN (E) MASTER (E) MASTER (E) BEDROOM 1 (N) DEN UP (N) HOME OFFICE (N)W.I.C OPEN TO BELOW (N ) H A L L W A Y UP BENCH (N) SHOWER  (N) HALLWAY (N) SHOWER DATA ELEC. LINEN LINEN CLOSET (E) BEDROOM 2 SHOWER (N) BATH (N)CLOSET (N) CLOSET (N) MURPHY TUB (N) SLOPE2% MIN PANEL (N) HOMEOFFICEBATH 24x30 CLR ROOM 2 24x30 CLR (N) BATHROOM 1 24x 3 0 C L R BATHROOM BEDROOM BED 49 ' - 3 " 7'-3 " 21 ' - 9 " 22 ' - 2 " 11 ' - 2 " 10 ' - 0 " 42'-3" 13'-0"8'-6"14'-0 1/4" 11'-9" 10 ' - 0 " 8'-9 " 6'-0" 13' - 7 " 24'-1" 11'-8" 16'-0" 40'-1" 2'-4" $  $   W03W05W05 W06 W08 D8 D5 D3 W9 W12 (N)GUARDRAIL 3'-0 1 / 4 " 2'-10" 1'-0" W07 $ 5'-0" 5'-0" W04 D2 D2 10 ' - 0 " D2 5'-4"4'-3" 7'-6 " 7'-5"4'-9"8'-4" W10 D2 D2 W9 W13 3'- 0 " 3'-0" 2'-1 0 " STUCCO ON THE UNDERSIDEWITH SPRINKLERSCLASS 'A' DECKING MATERIAL D2 6'- 6 " ESR 1757 W12 W07 W07 A 1 2 3 4 5 BCDE 5'-9 " (E ) S E T B A C K 9'- 8 " (E ) S E T B A C K (E) DRIVE WAY (E) LAWN 19'-7" PL 6 5 ' - 0 " PL 98'-0" PL 6 5 ' - 0 " PL 98'-0" 37'-6" V.I . F V.I. F UP PO R T C A R D I F F P L . 32'-10"PROJECTION DIM (N) A/C PROJECTION DIM PROJECTION DIM (E) WALL (E) DEMO (N) WALL (N) PONY WALL A-101.11PROPOSED 2ND FLOOR PLAN PROPOSED2ND FLOOR PLAN DRAWING NO. SCALE: 19 3 5 P O R T C A R D I F F P L A C E , DRAWING TITLE ISSUE RECORD NO. DESCRIPTION DATE ds Meta PROJECT NO. DESIGN STUIDO META, INC. 9630 ALONDRA BLVDBELLFLOWER, CA 90706 DIRECT : +1.213.703.0243OFFICE : +1.213.568.7777 www.dsmeta.com PACKAGE TITLE PROJECT STRUCTURAL ENGINEER MECH/ELECT/PLUMB ENGINEER ARE AND SHALL REMAIN THE PROPERTY THE DRAWINGS AND SPECIFICATIONS, ALL PRODUCTION & INTELLECTUAL NO PART THEREOF SHALL BE COPIED OROF THE DESIGN STUDIO META INC.; USED IN CONNECTION WITH ANY WORK PROJECT FOR WHICH THEY HAVE BEEN OR PROJECT OTHER THAN THE SPECIFIC CONSENT OF DESIGN STUDIO META INC. PREPARED WITHOUT THE WRITTEN IDEAS, DESIGNS, AND ARRANGEMENTS VISUAL CONTACT WITH THERE DRAWINGS EVIDENCE OF ACCEPTANCE OF THEREOR SPECIFICATION SHALL CONSTITUTE RESTRICTIONS. PROPERTY RIGHTS RESERVED PRELIMINARY PLAN 223-05-160 TA N G ' S R E S I D E N C E 01 1ST BLDG SUBMIT 09/06/2023 NE W P O R T B E A C H , C A 9 2 6 6 0 02 2ND HOA SUBMIT 12/26/2023 03 2ND BLDG SUBMIT 05/10/20241 04 3RD BLDG SUBMIT 07/11/20242 05 MODIFICATION SUBMIT 07/11/2024 N SCALE : 1/4" = 1'-0" 2 AD4019 AD40112 2 21 D1 DOOR SCHEDULE SYM.SIZE (W X H)TYPE MATERIAL LOCATION / REMARK F.L. 1 2 3'-0" X 6'-8"(N) ENTANCE DOOR / TEMP. GLASS QTY. 1 D2 22'-7" X 6'-8"9 D3 32'-8" X 6'-8"(N) BEDROOM,GARAGE/ TEMP. GLASS3 D4 2 (N) BATH ROOMS & CLOSETS4 WOOD W 1 2'-6" X 6'-8" TYPES 3 W D5 7'-9" X 7'-8"(E) KITHCHEN, MASTER BEDROOM/TEMP. GLASS2 D6 65'-0" X 6'-8"1 D7 2 1 3/8" SOLID CORE WOOD2'-6" X 6'-8"(E) GARAGE / FIRE RATED 20MIN / SELF-CLOSING / SELF-LATCHING1 D8 2 (E) MASTER BEDROOM / TEMP. GLASS1 4 2'-7" X 6'-8" 4 W H (E) FAMILY ROOM /TEMP. GLASS WOOD / GLASS ALUM. / GLASS WOOD / GLASS WOOD / GLASS WOOD / GLASS WOOD / GLASS H H W H 5 D9 5 (N) PANTRY12'-5" X 6'-8"WOOD D10 6 (N) LIVING ROOM17'-0" X 6'-8"WOOD / GLASS (N) BEDROOMS & CLOSETS 6 W H 3'-0" 6'-8 " SYM.SIZE (W X H)TYPE FRAME GLAZING A F.L. W H 44" M A X . SLIDING B W C C VINYL2'-0" X 4'-0" SLIDING A5'-0" X 4'-0" VINYL W 60" FIX FIX FIX WINDOW SCHEDULE TYPES W01 W02 W03 W05 FIX D W H FIX 4'- 9 " E SYM.SIZE (W X H)TYPE FRAME D VINYL2'-0" X 4'-0" GLAZING COLOR FIX C VINYL3'-0" X 4'-0"W06 W07 W08 W09 FIXD3'-0" X 5'-8" VINYL B2'-0" X 1'-4"VINYL SLIDING SLIDING E1'-11" X 1'-11"VINYL FIX W10 W11 W12 W13 W14 FIX F 44" M A X . W 3'-6 " F7'-0" X 3'-6" VINYL FIX/SLIDING 44" M A X . 44" M A X . A5'-0" X 4'-0" VINYL SLIDING REMARK REMARK BLACK BLACK BLACK BLACK BLACK BLACK NEW NEW NEW NEW NEW NEW REPLACING 3'-0" X 3'-6"B VINYL SLIDING 7'-6" X 4'-0"B VINYL SLIDING 3'-0" X 7'-0"G VINYL FIX / SWING COLOR BLACK BLACK BLACK BLACK BLACK BLACK REPLACING REPLACING NEW REPLACING W04 2'-0" X 4'-10"D VINYL FIX NEWBLACK QY 2 QY 1 1 2 2 2 1 3 2 2 44" M A X . G FIX 2 REPLACING 4 1 BLACKF7'-9" X 3'-6"VINYL FIX/SLIDING REPLACING 1 1'-10" 3'-2 "5.8 SF. 1'-10" * ALL WINDOW &DOOR GLAZING SHALL HAVE U FACTOR 0.32, SHGC FACTOR 0.25.* GLAZING IN HAZARDOUS LOCATIONS AS DEFINED IN CBC SECTION 2406.4 SHALL BE TEMPEREDGLASS, INCLUDING: SEE NOTE BELOW " GLAZING IN HAZARDOUS LOCATIONS" - SWINGING AND SLIDING DOORS. - SHOWER AND TUB ENCLOSURES, INCLUDING EXTERIOR WINDOW GLAZING. - GLAZING WITHIN 24" OF DOORS AND WITHIN 60" OF WALKING SURFACE.* GLAZING IN HAZARDOUS LOCATIONS a. INGRESS AND EGRESS DOORS b. PANERLS IN SLIDING OR SWINGING DOORS c. DOORS AND ENCLOSURE FOR HOT TUB, BATHTUB, SHOWERS (ALSO GLAZING IN WALL ENCLOSINGTHESE COMPERTMENTS WITHIN 5' OF STANDING SURFACE) d. IF WIHIN 2' OF VERTICAL EDGE OF CLOSED DOOR AND LESS THAN 5' OF WALKING SURFACE e. IN WALL ENCLOSING STAIRWAY LANDING f. GUARDS AND HANDRAILS. g. FENESTRATION MUST HAVE TEMPORARY AND PERMANENT LABELS 1. GLAZING NOTE ( SEE NOTE BELOW PER CBC SECTION 310.4 , 310.5 )ESCAPE OR RESCUE WINDOWS SHALL HAVE A MINIMUM NET CLEAR OPENABLE AREA OF 5.7 SQ.FTTHE MINIMUM NET CLEAR OPENABLE HEIGHT DIMENSION SHALL BE 24". THE MINIMUM NET CLEAROPENABLE WIDTH DIMENSION SHALL BE 20". WHEN WINDOWS ARE PROVIDED AS A MEANS OFESCAPE OR RESCUE, THEY SHALL HAVE A FINISHED SILL HEIGHT NOT MORE THAN 44" ABOVE THEFLOOR. 2. EMERGENCY ESCAPE WINDOW NOTE 3. NOTE - IF DOORBELL PROVIDED, DOORBELL BUTTONS SHALL NOT BE INSTALLED MORE THAN 48" ABOVEEXTERIOR FLOOR OR LANDING. (CRC R327.1.4)- FOR NEW AND RECONSTRUCTED STRUCTURES PROVIDED CLASS B FIRE CLASSIFICATION- IN BATHROOMS, GARAGES, LAUNDRY ROOMS, UTILITY ROOMS AND WALK-IN CLOSETS AT LEASTONE LUMINAIRE IN EACH OF THESE SPACES SHALL BE CONTROLLED BY AN OCCUPANT OR VACANCYSENSOR PROVIDING AUTOMATIC-OFF FUNCTIONALITY. (CENC SECTION150.0(K).2.E.I) DRAWING NO. SCALE: 19 3 5 P O R T C A R D I F F P L A C E , DRAWING TITLE ISSUE RECORD NO. DESCRIPTION DATE ds Meta PROJECT NO. DESIGN STUIDO META, INC. 9630 ALONDRA BLVDBELLFLOWER, CA 90706 DIRECT : +1.213.703.0243OFFICE : +1.213.568.7777 www.dsmeta.com PACKAGE TITLE PROJECT STRUCTURAL ENGINEER MECH/ELECT/PLUMB ENGINEER ARE AND SHALL REMAIN THE PROPERTY THE DRAWINGS AND SPECIFICATIONS, ALL PRODUCTION & INTELLECTUAL NO PART THEREOF SHALL BE COPIED OROF THE DESIGN STUDIO META INC.; USED IN CONNECTION WITH ANY WORK PROJECT FOR WHICH THEY HAVE BEEN OR PROJECT OTHER THAN THE SPECIFIC CONSENT OF DESIGN STUDIO META INC. PREPARED WITHOUT THE WRITTEN IDEAS, DESIGNS, AND ARRANGEMENTS VISUAL CONTACT WITH THERE DRAWINGS EVIDENCE OF ACCEPTANCE OF THEREOR SPECIFICATION SHALL CONSTITUTE RESTRICTIONS. PROPERTY RIGHTS RESERVED PRELIMINARY PLAN 223-05-160 TA N G ' S R E S I D E N C E 01 1ST BLDG SUBMIT 09/06/2023 NE W P O R T B E A C H , C A 9 2 6 6 0 02 2ND HOA SUBMIT 12/26/2023 03 2ND BLDG SUBMIT 05/10/20241 04 3RD BLDG SUBMIT 07/11/20242 05 MODIFICATION SUBMIT 07/11/2024 A-101.2 WINDOW SCHEDULENOTE 1 DOOR & WINDOW SCHEDULE 22 1 2 3 4 5 FL -1'-2"(E)1ST LOWER FLOOR FL +7'-6"(E) 2ND FLOOR FL +15'-6"(E) TOP CEILING FL +21'-5" (E) ROOF FL -1'-10"(E) GARAGE PR O P E R T Y L I N E 5'-9"(E) SETBACK V.I.F PR O P E R T Y L I N E 9'-8"(E) SETBACK V.I.F 12345 FL -1'-2" (E)1ST LOWER FLOOR FL +7'-6"(E) 2ND FLOOR FL +15'-6"(E) TOP CEILING FL +21'-5" (E) ROOF FL -1'-10"(E) GARAGE PR O P E R T Y L I N E 9'-8"(E) SETBACK V.I.F PR O P E R T Y L I N E 5'-9"(E) SETBACK V.I.F DRAWING NO. SCALE: 19 3 5 P O R T C A R D I F F P L A C E , DRAWING TITLE ISSUE RECORD NO. DESCRIPTION DATE ds Meta PROJECT NO. DESIGN STUIDO META, INC. 9630 ALONDRA BLVDBELLFLOWER, CA 90706 DIRECT : +1.213.703.0243OFFICE : +1.213.568.7777 www.dsmeta.com PACKAGE TITLE PROJECT STRUCTURAL ENGINEER MECH/ELECT/PLUMB ENGINEER ARE AND SHALL REMAIN THE PROPERTY THE DRAWINGS AND SPECIFICATIONS, ALL PRODUCTION & INTELLECTUAL NO PART THEREOF SHALL BE COPIED OROF THE DESIGN STUDIO META INC.; USED IN CONNECTION WITH ANY WORK PROJECT FOR WHICH THEY HAVE BEEN OR PROJECT OTHER THAN THE SPECIFIC CONSENT OF DESIGN STUDIO META INC. PREPARED WITHOUT THE WRITTEN IDEAS, DESIGNS, AND ARRANGEMENTS VISUAL CONTACT WITH THERE DRAWINGS EVIDENCE OF ACCEPTANCE OF THEREOR SPECIFICATION SHALL CONSTITUTE RESTRICTIONS. PROPERTY RIGHTS RESERVED PRELIMINARY PLAN 223-05-160 TA N G ' S R E S I D E N C E 01 1ST BLDG SUBMIT 09/06/2023 NE W P O R T B E A C H , C A 9 2 6 6 0 02 2ND HOA SUBMIT 12/26/2023 03 2ND BLDG SUBMIT 05/10/20241 04 3RD BLDG SUBMIT 07/11/20242 05 MODIFICATION SUBMIT 07/11/2024 1 EXISTING ELEVATION-1 A-301 EXISTING ELEVATION-1 SCALE : 1/4"=1'-0" 2 SCALE : 1/4"=1'-0"EXISTING ELEVATION-2 (E) SIDING (E) STONE VENEER (E) SIDING (E) SIDING (E) STUCCO 23 A B C D E FL -1'-2"(E)1ST LOWER FLOOR FL +7'-6"(E) 2ND FLOOR FL +15'-6"(E) TOP CEILING FL +21'-5" (E) ROOF FL -1'-10"(E) GARAGE PR O P E R T Y L I N E (E) SETBACK V.I.F PR O P E R T Y L I N E 34'-0"20'-4" (E) SETBACK V.I.F ABCDE FL -1'-2"(E)1ST LOWER FLOOR FL +7'-6"(E) 2ND FLOOR FL +15'-6"(E) TOP CEILING FL +21'-5" (E) ROOF FL -1'-10"(E) GARAGE PR O P E R T Y L I N E PR O P E R T Y L I N E 20'-4"(E) SETBACK V.I.F (E) SETBACK V.I.F 34'-10" DRAWING NO. SCALE: 19 3 5 P O R T C A R D I F F P L A C E , DRAWING TITLE ISSUE RECORD NO. DESCRIPTION DATE ds Meta PROJECT NO. DESIGN STUIDO META, INC. 9630 ALONDRA BLVDBELLFLOWER, CA 90706 DIRECT : +1.213.703.0243OFFICE : +1.213.568.7777 www.dsmeta.com PACKAGE TITLE PROJECT STRUCTURAL ENGINEER MECH/ELECT/PLUMB ENGINEER ARE AND SHALL REMAIN THE PROPERTY THE DRAWINGS AND SPECIFICATIONS, ALL PRODUCTION & INTELLECTUAL NO PART THEREOF SHALL BE COPIED OROF THE DESIGN STUDIO META INC.; USED IN CONNECTION WITH ANY WORK PROJECT FOR WHICH THEY HAVE BEEN OR PROJECT OTHER THAN THE SPECIFIC CONSENT OF DESIGN STUDIO META INC. PREPARED WITHOUT THE WRITTEN IDEAS, DESIGNS, AND ARRANGEMENTS VISUAL CONTACT WITH THERE DRAWINGS EVIDENCE OF ACCEPTANCE OF THEREOR SPECIFICATION SHALL CONSTITUTE RESTRICTIONS. PROPERTY RIGHTS RESERVED PRELIMINARY PLAN 223-05-160 TA N G ' S R E S I D E N C E 01 1ST BLDG SUBMIT 09/06/2023 NE W P O R T B E A C H , C A 9 2 6 6 0 02 2ND HOA SUBMIT 12/26/2023 03 2ND BLDG SUBMIT 05/10/20241 04 3RD BLDG SUBMIT 07/11/20242 05 MODIFICATION SUBMIT 07/11/2024 A-302 EXISTING ELEVATION-2 1 EXISTING ELEVATION-3 SCALE : 1/4"=1'-0" 2 EXISTING ELEVATION-4 SCALE : 1/4"=1'-0" (E) SIDING (E) STUCCO (E) STUCCO (E) SIDING (E) STONE VENEER 24 1 2 3 4 5 FL -0'-7"ENTRY FL +0'-0"1ST FLOOR FL +9'-0"2ND FLOOR FL +18'-0"TOP CEILING FL -1'-2"1ST LOWER FLOOR FL +7'-6"2ND LOWER FLOOR FL +15'-6" LOWER TOP CEILING FL +21'-5" ROOF FL -1'-10"GARAGE FIX 412 W12 W12 W8W7FIXW7FIXW7FIX D1D10 22"X5" VENT 1'-9" PR O P E R T Y L I N E PR O P E R T Y L I N E 9'-8" 5'-9" 1'-9" (E) SETBACK V.I.F (E) SETBACK V.I.F 23 ' - 6 " FR O N T R I D G E P E A K (E) GRADE 4'-0" 7'-11" FL -0'-7"ENTRY FL +0'-0"1ST FLOOR FL +9'-0"2ND FLOOR FL +18'-0" TOP CEILING FL -1'-2" 1ST LOWER FLOOR FL +7'-6"2ND LOWER FLOOR FL +15'-6" LOWER TOP CEILING FL +21'-5" (E) ROOF FL -1'-10" GARAGE 12345 D5 W13W13 W13 D5 W14 D3 W6 22"X5" VENT 1'-9" PR O P E R T Y L I N E PR O P E R T Y L I N E 1'-9" 23 ' - 0 " RE A R R I D G E P E A K (E) GRADE 9'-8"(E) SETBACK V.I.F 5'-9"(E) SETBACK V.I.F UNDER FLOOR VENT CALCULATION TOTAL UNDER FLOOR AREA : 1,062 SQ.FT REQUIRED (1/150): 7.08 SQ.FT (1,019.52 SQ.IN) PROVIDED : 7.64 SQ.FT (1,100 SQ.IN) (22"X5" VENT) X 10 EA = 1,100 SQ.IN DRAWING NO. SCALE: 19 3 5 P O R T C A R D I F F P L A C E , DRAWING TITLE ISSUE RECORD NO. DESCRIPTION DATE ds Meta PROJECT NO. DESIGN STUIDO META, INC. 9630 ALONDRA BLVDBELLFLOWER, CA 90706 DIRECT : +1.213.703.0243OFFICE : +1.213.568.7777 www.dsmeta.com PACKAGE TITLE PROJECT STRUCTURAL ENGINEER MECH/ELECT/PLUMB ENGINEER ARE AND SHALL REMAIN THE PROPERTY THE DRAWINGS AND SPECIFICATIONS, ALL PRODUCTION & INTELLECTUAL NO PART THEREOF SHALL BE COPIED OROF THE DESIGN STUDIO META INC.; USED IN CONNECTION WITH ANY WORK PROJECT FOR WHICH THEY HAVE BEEN OR PROJECT OTHER THAN THE SPECIFIC CONSENT OF DESIGN STUDIO META INC. PREPARED WITHOUT THE WRITTEN IDEAS, DESIGNS, AND ARRANGEMENTS VISUAL CONTACT WITH THERE DRAWINGS EVIDENCE OF ACCEPTANCE OF THEREOR SPECIFICATION SHALL CONSTITUTE RESTRICTIONS. PROPERTY RIGHTS RESERVED PRELIMINARY PLAN 223-05-160 TA N G ' S R E S I D E N C E 01 1ST BLDG SUBMIT 09/06/2023 NE W P O R T B E A C H , C A 9 2 6 6 0 02 2ND HOA SUBMIT 12/26/2023 03 2ND BLDG SUBMIT 05/10/20241 04 3RD BLDG SUBMIT 07/11/20242 05 MODIFICATION SUBMIT 07/11/2024 A-303 PROPOSEDELEVATION-1 SCALE : 1/4"=1'-0"1 PROPOSED ELEVATION-1 SCALE : 1/4"=1'-0"2 PROPOSED ELEVATION-2 7 4 3 1 1 3 1 8 ROOF1 FINISH INDEX NO. ITEM SPECIFICATIONMATERIAL WALLS2 LIGHTING4 WINDOW5 FLAT CONCRETE TILEMATCH TO EXISTING EAGLEROOFINGMODEL: CAPISTRANOCOLOR: 3581 ARCADIA CANYON BROWNCRRC#: 0918-0043IAPMO : ER-1900FIRE CLASSIFICATION: CLASS A STUCCO FIN.MATCH TO EXISTING PAREX USA LA HABRA PRODUCTMODEL: Lariat 821L (57)PAINT COLOR: Opulence OC-69 (Benjamin moor) 6 (N) WALL SCONCE LIGHTOLOGYMODEL: Prisma Outdoor Wall LightCOLOR: TEXTURE BRONZE 11" (N) VINYL WINDOWFRAME GLASS6 (N) GLAZING MILGARDMODEL: SunCoat® Low-E2 Glass MILGARDMODEL: V300 Trinsic™ SeriesCOLOR: BLACK CAPSTOCK PORCHPOST7 (N) PVC SIDING CROWN MOLDINGMODEL: RoyalWrap PVC ColumnsNon-Tapered Double Raised PanelPAINT COLOR: Opulence OC-69 (Benjamin moor) 5 8 GUARDRAIL (N) WROUGHT IRON CUSTOMMATEIAL: WROUGHT IRONPAINT COLOR: Twilight Zone 2127-10(Benjamin moor) WALLS3 SIDINGMATCH TO EXISTING KWPMODEL: Eco-side Lap sidingPAINT COLOR: Opulence OC-69 (Benjamin moor)ESR: 3746 9 GARAGEDOOR (N) FIBERGLASS PRECISIONMODEL:Olympus®PAINT COLOR: Twilight Zone 2127-10(Benjamin moor)9 2 65 (E) STUCCO NEW STUCCOMATCHING TO EXIST 4 (E) SIDING NEW SIDINGMATCHING TO EXIST NEW SIDINGMATCHING TO EXIST 7 10 BALCONYDECK (N) WEATHERWEAR Dex-O-TexMODEL:WeatherwearPAINT COLOR: Twilight Zone 2127-10(Benjamin moor)CLASSIFICATION: CLASS AESR: 1757 * PROVIDE CLASS B FIRE CLASSIFICATION FOR NEW AND RECONSTRUCTED STRUCTURES. NBMC 15.05.210 10 1 11 DECK (N) FIBERGLASS TIMBERTECHMODEL:Weathered Oak / COMPOSITECLASSIFICATION: CLASS AESR: 1667 11 1 25 ABCDE FL -0'-7" ENTRY FL +0'-0"1ST FLOOR FL +9'-0"2ND FLOOR FL +18'-0"TOP CEILING FL -1'-2"1ST LOWER FLOOR FL +7'-6"2ND LOWER FLOOR FL +15'-6" LOWER TOP CEILING FL +21'-5" (E) ROOF FL -1'-10"GARAGE W10 W9 W9 W13 W13 D5 PR O P E R T Y L I N E PR O P E R T Y L I N E 1'-9"1'-9" 20'-4"(E) SETBACK V.I.F 17'-10" (E) SETBACK V.I.F34'-10" A B C D E 412 FIX FIX FIX FL -0'-7"ENTRY FL +0'-0"1ST FLOOR FL +9'-0"2ND FLOOR FL +18'-0" TOP CEILING FL -1'-2" 1ST LOWER FLOOR FL +7'-6"2ND LOWER FLOOR FL +15'-6" LOWER TOP CEILING FL +21'-5" (E) ROOF FL -1'-10" GARAGE 412 W1 W1 W5W5 W3 FIXW3W2 W4 W4 22"X5" VENT PR O P E R T Y L I N E 6"PR O P E R T Y L I N E (E) SETBACK V.I.F 2'-8" 8'-0 " 34'-10" 32'-2" 20'-4"(E) SETBACK V.I.F DRAWING NO. SCALE: 19 3 5 P O R T C A R D I F F P L A C E , DRAWING TITLE ISSUE RECORD NO. DESCRIPTION DATE ds Meta PROJECT NO. DESIGN STUIDO META, INC. 9630 ALONDRA BLVDBELLFLOWER, CA 90706 DIRECT : +1.213.703.0243OFFICE : +1.213.568.7777 www.dsmeta.com PACKAGE TITLE PROJECT STRUCTURAL ENGINEER MECH/ELECT/PLUMB ENGINEER ARE AND SHALL REMAIN THE PROPERTY THE DRAWINGS AND SPECIFICATIONS, ALL PRODUCTION & INTELLECTUAL NO PART THEREOF SHALL BE COPIED OROF THE DESIGN STUDIO META INC.; USED IN CONNECTION WITH ANY WORK PROJECT FOR WHICH THEY HAVE BEEN OR PROJECT OTHER THAN THE SPECIFIC CONSENT OF DESIGN STUDIO META INC. PREPARED WITHOUT THE WRITTEN IDEAS, DESIGNS, AND ARRANGEMENTS VISUAL CONTACT WITH THERE DRAWINGS EVIDENCE OF ACCEPTANCE OF THEREOR SPECIFICATION SHALL CONSTITUTE RESTRICTIONS. PROPERTY RIGHTS RESERVED PRELIMINARY PLAN 223-05-160 TA N G ' S R E S I D E N C E 01 1ST BLDG SUBMIT 09/06/2023 NE W P O R T B E A C H , C A 9 2 6 6 0 02 2ND HOA SUBMIT 12/26/2023 03 2ND BLDG SUBMIT 05/10/20241 04 3RD BLDG SUBMIT 07/11/20242 05 MODIFICATION SUBMIT 07/11/2024 A-304 PROPOSEDELEVATION-2 SCALE : 1/4"=1'-0"2 PROPOSED ELEVATION-4 SCALE : 1/4"=1'-0"1 PROPOSED ELEVATION-3 2 1 7 2 1 65 65 3 3 (E) STUCCO (E) STUCCO NEW SIDINGMATCHING TO EXIST FIREPLACEVENT PER1/AD402 26 1" NOTES: SECTION 1708(b), UNIFORM, BUILDING CODE CALLS FOR FLASHING OF ALL EXTERIOR OPENING EXPOSED TOWEATHER TO MAKE THEM WEATHER PROOF. SINCE U.B.C. DOES NOT OUTLINE PROCEDURES FOR WINDOWFLASHING, TECHNIQUES SHOWN HERE ARE RECOMMENDED. USE "MOISTOP" FLASHING BY FORTIFIBERCORP., OR EQUAL WHENEVER POSSIBLE FOR FLASHING MATERIAL. CAULK BACK OF WINDOW FRAMESBEFORE SETTING. USE WINDOWS THAT ARE WATERTIGHT. 26GA. G.I. FLASHING REQUIRED AS SHOWN IN OTHER WINDOW DETAILS TO BE INSTALLED BY SHEET METALCONTRACTOR. LINE WIRE, WHEN USED AS BACKING TO SUPPORT WATER-RESISTANT BUILDING PAPER OR FELT BENEATHLATH FOR STUCCO SHOULD BENEATH INSTALLED ACCORDING TO INDUSTRY STANDARDS AND PRACTICE. NOATTACHMENT DEVICE NOR THE WIRE BACKING SHOULD COVER OR PENETRATE FLASHING MATERIAL.PERIPHERAL FLASHING AT ALL EDGES OF WALL OPENING MUST COVER WIRE BACKING. STARTING AT THE BOTTOM OF THE WALL (SOLEPLATE), LAT WATER-RESISTANT PAPER UNDERTHE SILL STRIP. CUT ANY EXCESSWATER-RESISTANT PAPER THAT MAY EXTENDABOVE THE SILL FLANGE ON EACH SIDE OF THEOPENING. (SHOWING IN DIAGRAM AS SHORTDASH LINES). INSTALL SUCCEEDING COURSESOF WATER-RESISTANT PAPER(B,C,ETC.) OVERJAMB AND HEAD FLANGES IN SHINGLE-BOARDFASHION AFTER SILL STRIP IS IN PLACE ATTACH JAMBSTRIPS (SIDE OF OPENING ) AT LEAST 12"WIDE WITH INSIDE EDGE OF FLASHING FLUSHWITH EDGE OF WINDOW OPENING. STARTJAMB STRIPS 6" ABOVE THE LOWER EDGE OFTHE HEADER ( TOP OF WINDOW OPENING) APPLY A CONTINUOUS BEAD OF BUTYL RUBBERSEALANT TO THE BACK SURFACES OF THEWINDOW FLANGE, THEN PLACES THE WINDOWINTO THE ROUGH OPENING WITH FLANGE OVERTHE INSTALLED FLASHING STRIPS, AFTERWINDOW IS PLACED, INSTALLED FLASHINGSTRIPS. AFTER WINDOW IS PLACED, INSTALL THEHEAD FLASHING OVER THE WINDOW FLANGE.THIS IS ANOTHER STRIP OF FLASHING AT LEAST12" WIDE ATTACH A SILL STRIP OF FLASHING MATERIALAT LEAST 12" WIDE WITH THE TOP EDGE EVENWITH THE TOP EDGE OF THE ROUGH SILL.EXTEND THIS SILL STRIP AT LEAST 12"BEYOND THE EDGE OF THE ROUGH OPENINGFOR WINDOW. ATTACH FLASHING WITHGALVANIZED ROOFING NAILS OR RUST -RESISTANT STAPLES. BA 6" SEE NOTESSEE NOTES12" ROUGHSILL SILL STRIP WINDOW ROUGHED - INOPENING EDGE OFFLANGE DC 2 x BLOCKING 2X TREATED SILL PLATE INSULATION 18 " M I N . PER STRUCT. PLAN PLYWOOD PER STRUCTURE PLAN GYP. BD 2X WD' STUD INSULATION PER TITLE-24 PLYWOOD PERSTRUCT. PLAN GRADE “D” PAPER OVER EXTERIOR STUCCO & WIRE LATH WEEP SCREED26 GA. G.I STUCCO 4" MIN. ABOVE EARTH2" MIN ABOVE PAVED AREA PER TITLE 24 WOOD BASE SHEATHING UNDER EXTERIOR LATH. PROVIDE TWO LAYERS OF MIN. 3" TO CONC. FINMIN. 8" TO SOIL SIDE ELEVATION FRONT ELEVATION PLAN 1/4" THICK T.S. DOWNSPOUT GUARD PAINTED FINISH SURFACE 3'LX2'W CONC. SPLASH BLOCK (NOT REQUIRED AT CONCRETE SURFACE) 1/4" STEEL PLATE W/ 1/2" DIA. EXP. BOLT. TYP. EXTERIOR WALLPER PLAN 1" MIN. 1" M I N . 1" MIN. 3'-0 " 1'-6 " FLOOR FINISH TBD. 2"x4" STUD WALL @ 16"O.C. 2X DOUBLE TOP PLATE (STUD GRADE) 2X CEILING JOISTS2X SOLID BLOCKING PE R P L A N 5/8" TYP. X GYP BOARD@ BOTH SIDE COVERD BASE WOOD (STC 50) P.T INSULATION PER T-24 1 1/2" x 1 1/2" GUARDRAIL POST 2" x 1 1/2" TUBE STEEL TOP RAIL5/8 " SQUARE STL. BAR SPACING WELD ALL SIDE OFINTERMEDIATE GUARDPOST 42 " M I N R A I L H E I G H T 4'-0" MAX O.C LE S S T H A N 4" LESS THAN4" Ø4" SPHERE SHALL NOT PASS Ø4" SPHERE SHALL NOT PASS 7.7 5 " M A X . 11" 2" 1"10" MIN.1 1/4" 6'-8 " M I N . CEILING FLOOR METAL THRESHOLDA AT 1:2 SLOPE 12 MAX.1/4" 1/2" MAX. DOOR IN CLOSEDPOSITION CL * THRESHOLDS. THRESHOLDS AT DOORWAYS SHALL NOT EXCEED 3/4 INCH (19.1 MM) INHEIGHT ABOVE THE FINISHED FLOOR OR LANDING FOR SLIDING DOORSSERVING DWELLING UNITS OR 1/2 INCH (12.7 MM) ABOVE THE FINISHEDFLOOR OR LANDING FOR OTHER DOORS. RAISED THRESHOLDS ANDFLOOR LEVEL CHANGES GREATER THAN 1/4 INCH (6.4 MM) AT DOORWAYSSHALL BE BEVELED WITH A SLOPE NOT GREATER THAN ONE UNIT VERTICAL IN TWO UNITS HORIZONTAL (50-PERCENT SLOPE). * EXCEPTION: IN OCCUPANCY GROUP R-2 OR R-3, THRESHOLD HEIGHTSFOR SLIDING AND SIDE-HINGED EXTERIOR DOORS SHALL BE PERMITTEDTO BE UP TO 73/4 INCHES (197 MM) IN HEIGHT IF ALL OF THE FOLLOWING APPLY: 1. THE DOOR IS NOT PART OF THE REQUIRED MEANS OF EGRESS. 2. THE DOOR IS NOT PART OF AN ACCESSIBLE ROUTE AS REQUIRED BY CHAPTER 11A OR 11B. 3. THE DOOR IS NOT PART OF AN ADAPTABLE OR ACCESSIBLEDWELLING UNIT. WP MEMBRANE, REDGARDOR APPROVED EQUAL.INSTALL PER MANUFACTURERREQUIREMENTS PLYWOOD STL ANGLE, POWDERCOATED FINISH BEAMS, S.S.D SCHEDULED STUCCOFINISH PER FINISH INDEX SCHEDULED FINISHPER FINISH INDEX DRAWING NO. SCALE: 19 3 5 P O R T C A R D I F F P L A C E , DRAWING TITLE ISSUE RECORD NO. DESCRIPTION DATE ds Meta PROJECT NO. DESIGN STUIDO META, INC. 9630 ALONDRA BLVDBELLFLOWER, CA 90706 DIRECT : +1.213.703.0243OFFICE : +1.213.568.7777 www.dsmeta.com PACKAGE TITLE PROJECT STRUCTURAL ENGINEER MECH/ELECT/PLUMB ENGINEER ARE AND SHALL REMAIN THE PROPERTY THE DRAWINGS AND SPECIFICATIONS, ALL PRODUCTION & INTELLECTUAL NO PART THEREOF SHALL BE COPIED OROF THE DESIGN STUDIO META INC.; USED IN CONNECTION WITH ANY WORK PROJECT FOR WHICH THEY HAVE BEEN OR PROJECT OTHER THAN THE SPECIFIC CONSENT OF DESIGN STUDIO META INC. PREPARED WITHOUT THE WRITTEN IDEAS, DESIGNS, AND ARRANGEMENTS VISUAL CONTACT WITH THERE DRAWINGS EVIDENCE OF ACCEPTANCE OF THEREOR SPECIFICATION SHALL CONSTITUTE RESTRICTIONS. PROPERTY RIGHTS RESERVED PRELIMINARY PLAN 223-05-160 TA N G ' S R E S I D E N C E 01 1ST BLDG SUBMIT 09/06/2023 NE W P O R T B E A C H , C A 9 2 6 6 0 02 2ND HOA SUBMIT 12/26/2023 03 2ND BLDG SUBMIT 05/10/20241 04 3RD BLDG SUBMIT 07/11/20242 05 MODIFICATION SUBMIT 07/11/2024 AD-401 TYP. DETAIL 2 1 TYP. WINDOW & DOOR FLASHING DETAIL TRANSITION THRESHOLD 7 6 4 RAIN GUTTER DOWN SPOT TYP. INTERIOR WALL DETAIL5 TYP. EXT. WALL & FOUNDATION 3 TYP. GUARDRAIL DETAIL TYP. WD STAIR DETAIL9 1 1 S12210* SEE FOR CONNECTION DETAILS TYP. HANDRAIL DETAIL11GRAB BAR DETAIL 1 12 TYP. DECK ASSEMBLY DETAIL 2 GARAGE WALL DETAIL10 1 *MIN. STAIR CLEAR WIDTH OF 36" * PROVIDE GUARDS WHERE THE OPEN SIDE IS MORE THAN 30"MEASURED VERTICALLY TO THE FLOOR OR GRADE BELOW AT ANY POINT WITHIN 36" HORIZONTALLY TO THE EDGEOR THE OPEN SIDE 11 GRAB BAR REINFORCEMENT8 2 13 TYP. GARAGE CEILING FINISH 2 * REINFORCEMENT SHALL BE 2X8 SOLID LUMBER MINIMUM SUBFLOOR PRIMER 1-1/4" THK, SELF-LEVELING GYPSUM 27 DRAWING NO. SCALE: 19 3 5 P O R T C A R D I F F P L A C E , DRAWING TITLE ISSUE RECORD NO. DESCRIPTION DATE ds Meta PROJECT NO. DESIGN STUIDO META, INC. 9630 ALONDRA BLVDBELLFLOWER, CA 90706 DIRECT : +1.213.703.0243OFFICE : +1.213.568.7777 www.dsmeta.com PACKAGE TITLE PROJECT STRUCTURAL ENGINEER MECH/ELECT/PLUMB ENGINEER ARE AND SHALL REMAIN THE PROPERTY THE DRAWINGS AND SPECIFICATIONS, ALL PRODUCTION & INTELLECTUAL NO PART THEREOF SHALL BE COPIED OROF THE DESIGN STUDIO META INC.; USED IN CONNECTION WITH ANY WORK PROJECT FOR WHICH THEY HAVE BEEN OR PROJECT OTHER THAN THE SPECIFIC CONSENT OF DESIGN STUDIO META INC. PREPARED WITHOUT THE WRITTEN IDEAS, DESIGNS, AND ARRANGEMENTS VISUAL CONTACT WITH THERE DRAWINGS EVIDENCE OF ACCEPTANCE OF THEREOR SPECIFICATION SHALL CONSTITUTE RESTRICTIONS. PROPERTY RIGHTS RESERVED PRELIMINARY PLAN 223-05-160 TA N G ' S R E S I D E N C E 01 1ST BLDG SUBMIT 09/06/2023 NE W P O R T B E A C H , C A 9 2 6 6 0 02 2ND HOA SUBMIT 12/26/2023 03 2ND BLDG SUBMIT 05/10/20241 04 3RD BLDG SUBMIT 07/11/20242 05 MODIFICATION SUBMIT 07/11/2024 AD-402 FIREPLACESPECIFICATION FIREPLACE INSTALLATION / SPECIFICATION1 MANUFACTURE : WOODLAND DIRECTMODEL : MONTIGO DELRAY DIRECT VENT GAS FIREPLACE-48" FIREPLACE DETAIL2 1 28 From:Jim Mosher To:CDD Subject:Comment on ZA agenda Item 3 (12/12/2024 meeting) Date:December 11, 2024 9:49:59 AM [EXTERNAL EMAIL] DO NOT CLICK links or attachments unless you recognize the sender and know the content is safe.Report phish using the Phish Alert Button above. With regard to Item 3 (Tang Residence, PA2024-0187) on the December 12, 2024, Newport Beach Zoning Administrator agenda: On handwritten page 10, "SECTION 4. DECISION" of the proposed resolution appears to be missing the usual CEQA declaration. -- Jim Mosher Zoning Administrator - December 12, 2024 Item No. 3a - Additional Materials Received Tang Residence Modification Permit (PA2034-0187)