HomeMy WebLinkAboutF_A-3-0 - ROOF PLANUP 2x ROOF RAFTER (PER STRUCT.) INTERIOR FINISH (PER PLANS, WHERE OCCURS) AIR-PERMEABLE INSULATION (PER PLANS) MIN. 2 LAYERS 15# ROOF FELT O/. CAP SHT. 1/2" CDX PLYWD. SHT'G. MIN. (REF. STRUCT) SHINGLES TO BE NO. 1 GRADE WESTERN RED CEDAR W/. A MAX. MOISTURE CONTENT OF 25% FASTENERS PER NOTE #3 LENGTH TO BE DETERMINED BY UNDERLAYMENT LAYER, REF. NOTE #5 (2) PER SHINGLE/SHAKE 12 SLOPE PER PLAN (MIN. 4:12 SHAKES) (MIN. 3:12 SHINGLES) WOOD SHINGLE NOTES: 1. SHINGLES TO BE INSTALLED ON SOLID SHT'G. IN ACCORDANCE WITH CBC TABLE 1507.8 2. FASTENERS MUST BE HOT-DIPPED GALVANIZED W/. ZINC COATING WTS. IN ACC. W/. ASTM A 153, OR S.S. 3. 'FSR TREATMENT, INC.' CLASS 'A' ROOFING ASS'Y. ICC# ESR-1410 STARTER COURSES AT THE EAVE MUST BE DOUBLED, W/. FIRST COURSE BEING FULL-SIZE TREATED SHINGLES, SUPPLIED BY 'CHEMCO, INC.' 15" OR 18" TREATED SHINGLES MAY BE USED FOR THE FINAL COURSE AT THE RIDGE. 4. PRODUCTS LISTED AS 'CLASS B' SHINGLES MUST BE INSTALLED O/. SPACED OR SOLID SHT'G. COVERED EITHER W/. ONE LAYER OF 1-1/4" DENS-DECK ROOF BOARD, MANUFACTURED BY GEORGIA PACIFIC CORP., OR W/. ONE LAYER MINERAL-SURFACED CAP SHEET COMPLYING W/. ASTM D 3909. WHERE UNDERLAYMENT IS REQ'D., THE UNDERLAYMENT SHALL BE INSTALLED OVER THE DENS-DECK BOARD OR MINERAL-SURFACED CAP SHEET. FASTENER LENGTH FOR THE SHAKES MUST BE INCREASED FOR THE THICKNESS OF THE DENS-DECK BOARD OR CAP SHEET. THE DENS-DECK BOARDS MUST BE FASTENED TO SPACED OR SOLID SHT'G. USING A MIN. OF FOUR FASTENERS PER BOARD TO AVOID PANEL SHIFTING PRIOR TO INSTALLATION OF THE SHAKES. THE MINERAL-SURFACED CAP SHEET MUST BE INSTALLED WITH 2" OVERLAPS ON THE SIDES AND ENDS, AND ATTACHED W/. A SUFFICIENT NUMBER OF FASTENERS TO HOLD THE SHEET IN PLACE PRIOR TO INSTALLATION OF THE SHAKES. 5. MIN. CAP SHT. -REF. NOTE #5 ABV. EXPOSURE & OVERLAP PER CBC TABLE 1507.8.6 AUTOMATIC SPRINKLERS TO BE INSTALLED THROUGHOUT & IN ATTIC AREAS IN ACCORDANCE WITH C.N.B. STANDARDS (PROVIDE SEPARATE APPLICATION, REF. 8/T-1) 6. EAVES TO BOXED 1-HR. ASSEMBLY PER NBMC 15.04.2207. UNVENTED ENCLOSED RAFTER ASSEMBLY NOTE: 1. AT UNVENTED ENCLOSED RAFTER ASSEMBLY PROVIDE 1X SLEEPER OVER ROOF UNDERLAYMENT FOR MIN. 1/4" VENTED AIR SPACE SEPARATE WOOD SHAKE OR SHINGLE AND ROOFING UNDERLAYMENT TO MEET REQUIREMENT OF THE SECTION R806.5 OF CBC 2. NO INTERIOR CLASS I VAPOR RETARDER SHALL BE INSTALLED ON THE CEILING SIDE (ATTIC FLOOR) OF THE UNVENTED ATIIC ASSEMBLY OR ON THE CEILING SIDE OF THE UNVENTED ENCLOSED ROOF FRAMING ASSEMBLY. CONT. BUILT-UP FASCIA & SHDW. BD. -ARCH TO APPV. SIZE PRIOR TO CUTTING ROOF RAFTERS COPPER GUTTER AS SEL. ROOFING PER PLAN & MAT. SCHED. O/. ROOFING FELT (MIN. 2 LAYERS 15#) 2x ROOF RAFTERS PER STRUCT. ROOF SHT'G PER STRUCT. EXTERIOR FINISH PER PLANS & MAT. SCHED. COPPER DRIP EDGE (TYP.) 2X SOLID BLK'G. 1x6 T&G SOFFIT PANELS - PAINT & SEAL (COLOR AS SEL.) PROVIDE VENTS FOR ATTIC VENTILATION PER CRC R806 AS NEEDED 9 1 / 4 " 1 1/2"3/4" 5 1 / 2 " 3 3 / 4 " OVERHANG PER PLANS 1/ 4 " 9 1 / 4 " 9 1 / 4 " 9 1 / 4 " 2X SOFFIT FRM'G TYP. REVEAL -COORD. W/. EAVES RATED MIN. 24" TO PL. FILLED REGION INDICATES ATTIC SPACE-REF. ATTIC VENTILATION CALCS. ROOF PLAN LEGEND 1x T&G SOFFIT O/. TYVEK (OR EQUIV.) PAINT (ARCH. TO APPV.) INTERIOR FINISH, PER PLAN (WHERE OCCURS) 'TYVEK' OR EQ. BLDG. WRAP CDX PLYWD. SHT'G. (PER STRUCT'L.) THERMAL BATT INSUL'N. CAULK & SEAL ROOFING MATERIAL (REF. PLANS) O/. 30# ROOF FELT & CDX PLYWD. ROOF SHT'G. (PER STRUCT'L.) CONT. BUILT-UP FASCIA & SHDW. BD. -ARCH. TO APPV. SIZE PRIOR TO CUTTING ROOF RAFTERS CAULK & SEAL BASE FLASHING EAVE FLASHING W/. DRIP (BY ROOFING MFGR.) TO MATCH ROOF EXTERIOR FINISH -REF. PLANS & MAT. SCHED. 2x BLK'G. 1" OVERHANG PER PLANS 2x SOFFIT FRM'G. MIN. 24" TO PL. 2x ROOF RAFTER (PER STRUCT.) INTERIOR FINISH (PER PLANS, WHERE OCCURS) AIR-PERMEABLE INSULATION (PER PLANS) MIN. 30# ROOF FELT-(2) LAYERS GAF VERSASHIELD UNDERLAYMENT 15/32" CDX PLYWD. SHT'G. MIN. (REF. STRUCT) FASTENERS PER MFGR. INSTRUCTIONS 12 SLOPE PER PLAN STANDING SEAM METAL (ZINC OR EQUIV.) -REF. MAT. SCHED. A/A-5, CLASS 'A' ASSY. TYP.6" - 10"6" MIN. DOUBLE FOLD 3/4" LOCK, ALT. METHOD CLEATS @ 18" O.C. MAX. CONT. LOCK STRIP, SOLDERED ARCH. TO APPV. 12"-16" 1- 1 / 2 " H I G H VALLEY DETAIL PRODUCT LISTING: ICC # ESR-2048, CB-150 UNVENTED ENCLOSED RAFTER ASSEMBLY NOTE: NO INTERIOR CLASS I VAPOR RETARDER SHALL BE INSTALLED ON THE CEILING SIDE (ATTIC FLOOR) OF THE UNVENTED ATTIC ASSEMBLY OR ON THE CEILING SIDE OF THE UNVENTED ENCLOSED ROOF FRAMING ASSEMBLY. 1/4" DENSGLASS OR EQUIV. STONE FINISH AS OCCUR PER PLAN REF. MAT. SCHED. REF. A/A-4.0 2% MIN. DIAMOND OR EQUIV. SELF FURRING LATH PLYWD. SHT'G., SHEAR PANEL PER STRUCT. ROOF/DECK JOISTS AS OCCUR, REF. STRUCT., PROVIDE INSULATION PER SCHED. 2x SHAPED WOOD CAP VAPOR BARRIER ('TYVEK' OR EQUIV.) MIN. TWO (2) LAYERS OF GRADE 'D' PAPER ROOF SHEATHING, REF. STRUCT. "EVERGUARD® TPO" 45-MIL TO 80-MIL OR "EVERGUARD EXTREME® TPO" 50-MIL TO 80-MIL, FULLY ADHERED WITH "EVERGUARD® LOW VOC TPO BONDING ADHESIVE", APPLIED AT A RATE OF 0.91 GAL/SQ (TOTAL), ½ TO MEMBRANE AND ½ TO SUBSTRATE -REF. ITEM 2A2/APPENDIX A-TABLE 2 OF UL ER1306 FLASH & COUNTER FLASH AS REQ'D. CA P F L A S H I N G 6" M I N . PE R . M F G R . 8" M I N . PE R P L A N PA R A P E T H T . MIN. ¼-IN. THICK UNITED STATES GYPSUM CO. SECUROCK® GYPSUM-FIBER ROOF BOARD OR SECUROCK® GLASS-MAT ROOF BOARD MECHANICALLY FASTENED WITH DRILL-TEC™ RHINOBOND® TPO XHD PLATES OR DRILL-TEC™ RHINOBOND® TPO XHD TREAD SAFE PLATES AND DRILL-TEC™ #14 FASTENERS SECURED INTO THE PLYWOOD OR WOOD PLANK WITHIN A MAXIMUM CONTRIBUTORY AREA OF 2.67 S.F. PER FASTENER (12 FASTENERS PER 48 X 96 IN. BOARD) -REF. ITEM C-18/TABLE 6 OF UL ER1306 SUBSTRATE PER STRUCT. BA S E F L A S H I N G 6" M N I . 6" MIN. LAP "EVERGUARD® TPO" NOTE: APPLY EVERGUARD TPO & PVC CUT EDGE SEALANT TO ALL CUT REINFORCED TPO & PVC EDGE -INSTALL PER MFGR. SEPCS & REF. MFGR. MANUAL FOR ADDITIONAL DTL. AND WARRANTY AS WELL AS UL ER1306 WIDTH PER PLAN "EVERGUARD® TPO" WATERPROOFING MEMBRANE 1/4:12 (2%) ≤SLOPE ≤2.5:12 STONE CAP TO MATCH WALL FINISH A-4.02 A-4.1 A-4.0 A-4.1 2 1 1 1 A-5.2 1 A-5.2 2 A-5.2 2 A-5.2 7: 1 2 7: 1 2 7:12 9: 1 2 9: 1 2 9: 1 2 9: 1 2 9: 1 2 6: 1 2 6:12 6: 1 2 7:127:127:127:127:127:127:127:127:127:12 3: 1 2 3: 1 2 3:12 3:12 9: 1 2 9: 1 2 7: 1 2 7:12 6: 1 2 6: 1 2 7:12 7: 1 2 7:12 7: 1 2 7: 1 2 35.59' 35.59' 33.88'33.88' 34.19'33.88'33.88' 32.79' 30.85' 33.00' 32.99' 35.27' 1 2 2 1 111 1 1 2 1 2 8 3 / 4 " F.O.F. 3' - 3 3 / 4 " 5 3 / 4 " F.O.F. 4' - 1 1 " 8 3 / 4 " F.O.F. 3' - 3 3 / 4 " 4 3 / 4 " F.O.F. 4' - 1 3 / 4 " 4 3/4" F.O.F. 9' - 7 3/4" 4 3 / 4 " 7 1/4" F.O.F. 18' - 8" 4 3 / 4 " 4 3/4" F.O.F. 11' - 3 3/8" 5 3/4" F.O.F. 9' - 6 3/4" 4 3/4" F.O.F. 11' - 3 3/8" 4 3 / 4 " F.O.F. 3' - 8 1 / 2 " 4 3 / 4 " 3' - 8 1 / 2 " F.O.F. 9' - 4 5/8"4 3/4" 22' - 7 1/4" F.O.F. 5' - 4 7/8"5 3/4" F.O.F. 18' - 9 1/2"5 3/4" F.O.F. 10' - 6 5/8"8 3/4" 13' - 3 1/8" 5 3 / 4 " F.O.F. 12 ' - 1 0 3 / 4 " 5 3/4" F.O.F. 40' - 6 1/4" 5 3/4" 22 ' - 8 3 / 8 " 8 3 / 4 " 8 3 / 4 " 3 3 343 4 3 4 3 4 4 3 4 3 4 4 3 4 2 5 6 F.O.F. 18 ' - 1 0 " 2 2 VIEW DECK BELOW (SEE A-2.2) VIEW DECK BELOW (SEE A-2.2) A/C. WELL (SEE A-2.2) 7 7 7 2% 2% 1 A-5.3 1 A-5.3 1 A-5.0 1 A-5.0 2 A-5.0 2 A-5.0 2 A-5.3 2 A-5.3 2 A-5.1 2 A-5.1 1 A-5.1 1 A-5.1 38.00'38.00' 38.00' 38.00' 3: 1 2 3: 1 2 3:12 3:12 3:12 3:123:123:12 3:12 3:12 3: 1 2 2% 8 38.00' 1 MAX. 4' - 0" MA X . 2' - 0 " 8 3:12 3: 1 2 3:12 ATTIC VENT CALC: 37.08 S.F. ATTIC SPACE 524.68/150 = 35.59 S.I. DORMER VENTS = 100 S.I. x 2 = 200 S.I. 35.59 S.I. < 200 S.I. (REQ'D.) ATTIC VENT CALC: 235.32 S.F. ATTIC SPACE 235.32/150 = 225.9 S.I. DORMER VENTS = 100 S.I. x 3 = 300 S.I. 35.59 S.I. < 300 S.I. (REQ'D.) ATTIC VENT CALC: 192.25 S.F. ATTIC SPACE 192.25/150 = 184.56 S.I. DORMER VENTS = 100 S.I. x 2 = 200 S.I. 184.56 S.I. < 200 S.I. (REQ'D.) 3:12 3:12 6' - 1 1 / 4 " 38.00' 3: 1 2 3: 1 2 2% 23 ' - 0 7 / 8 " 1 1 8 2% 8 JOB NO. DATE DOCUMENT VALID UPON ORIGINAL SIGNATURE SHEET NO. REVISIONS OW N E R I N F O R M A T I O N : PROJECT NAME STATUS Th e s e d o c u m e n t s a r e t h e p r o p e r t y o f B R A N D O N A R C H I T E CT S , C h r i s t o p h e r B r a n d o n , pr i n c i p a l a r c h i t e c t , a n d a r e n o t t o b e d u p l i c a t e d , al t e r e d o r u t i l i z e d i n a n y w a y b y a n y o t h e r pa r t y w i t h o u t t h e e x p r e s s e d a u t h o r i z a t i o n o f B R A N D O N A R C H I T E C T S . A n y u n a u t h o r i z e d du p l i c a t i o n o r a l t e r a t i o n o f t h e s e d o c u m e n t s b y a n y p a r t y i s a v i o l a t i o n o f B R A N D O N AR C H I T E C T S e x p r e s s e d c o m m o n l a w c o p y r i g h t a n d o t h e r p r o p e r t y r i g h t s t h e r e t o , a n d i s su b j e c t t o f u l l c i v i l l i a b i l i t i e s a n d p e n a l t i e s . T he s e p l a n s a r e a l s o n o t t o b e a s s i g n e d t o a n y th i r d p a r t y w i t h o u t o b t a i n i n g w r i t t e n a u t h o r i z a t i o n a n d e x p r e s s e d p e r m i s s i o n b y B R A N D O N AR C H I T E C T S , w h o s h a l l t h e n b e h e l d h a r m l e s s a n d a b s ol v e d o f a n y l i a b i l i t y r e g a r d i n g a n y us e o f t h e s e d o c u m e n t s b y s u c h t h i r d p a r t y , w h e t h e r d e p i c t e d o r i m p l i e d h e r e o n . PROJECT MANAGER/ARCHITECT A-3.0 06/16/20 2019-41 RO O F P L A N EAST BAY MANOR EA S T B A Y M A N O R KS R V D , L L C , 42 9 S A N T A M O N I C A B L V D . , SU I T E 3 6 0 SA N T A M O N I C A , C A 9 0 4 0 1 CDP SECOND 14 1 7 E A S T B A Y NE W P O R T B E A C H , C A 9 2 6 6 3 Designer 1 1/2" = 1'-0"3 WOOD SHINGLE ROOFING 1 1/2" = 1'-0"4 EAVE DETAIL 1 1/2" = 1'-0"5 RAKE DETAIL NOTE:ALL DIMS. ARE TO FACE OF STUD (F.O.S.) OR FACE OF SHT'G. (F.O.S.) TYP. U.N.O. EAVE DIMS. ARE FROM FACE OF SHT'G. TO FACE OF FINISH FASCIA A NO. REVISION DATE 1 1/2" = 1'-0"2 METAL ROOFING DETAIL PROJECT NORTH 3" = 1'-0"6 FLAT ROOF DETAIL 1/4" = 1'-0"1 ROOF PLAN KEYNOTE LEGEND 1 ROOF - STANDING SEAM METAL W/. SS. METAL ZINC FINISH - REF. MAT. SCHED. A-4.0 & DTL. 2/A-3.0 2 WOOD SHINGLE ROOFING PER MATERIAL SCHEDULE A-4.0 AND DTL 3/A-3.0. 3 METAL GUTTER - KYNAR FINISH OR EQUIV., SHAPE AS SEL. - PROVIDE SHOP DWGS. TO ARCH. PRIOR TO FAB. 4 ROOF FASCIA - EAVE AS DIMENSIONED (REF. ROOF PLAN & RCP FOR DETAILS) 5 EXTERIOR GUARD - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTLS. 12/AD-1 6 EXTERIOR GLASS GUARD - 34" - 38" ABV. NOSING (36" TYP. U.N.O.), REF. DTL. 4 & 13/AD-1 7 A/C. CONDENSER UNIT - SIZE TBD - PROVIDE POWER AND SOUND DAMPENING PAD AS REQ'D. (SOUND ATT. REQ'D. BY C.N.B.) SEP. PERMIT REQ'D, REF. 7/T-1 DEF. SUBMT'L. #2 8 CRICKET - SLOPE 2% MIN., REF. ROOF PLAN A-3.0 TRUE NORTH DIMENSION NOTE: ALL DIMS. ARE TO FACE OF STUD (F.O.S.) OR FACE OF SHT'G. (F.O.S.) TYP. U.N.O. EAVE DIMS. ARE FROM FACE OF SHT'G. TO FACE OF FINISH FASCIA ENLOSED ATTIC AND ENCLOSED RAFTER SPACES VENTING NOTES: 1. ENCLOSED ATTIC AND ENCLOSED RAFTER SPACES SHALL HAVE CROSS VENTILATION BY VENTILATION OPENING PROTECTED AGAINST THE ENTRANCE OF RAIN OR SNOW UNLESS THEY MEET THE REQUIREMENT OF SECTION R806.5 FOR UNVENTED ATTIC AND UNVENTED ENCLOSED RAFTER ASSEMBLIES. VENTILATION OPENING SHALL HAVE THE LEAST DIMENSION OF 1/16”MIN. AND 1/4”MAX OTHERWISE THE OPENING SHALL HAVE THE CORROSION-RESISTANT WIRE CLOTH SCREENING, HARDWARE CLOTH, PERFORATED VINYL OR SIMILAR MATERIAL WITH OPENINGS HAVE A LEAST DIMENSION OF 1/16”MIN. AND 1/4”MAX. OPENING IN ROOF FRAMING MEMBERS SHALL BE PER THE REQUIREMENT OF SECTION R802.7. REQUIRED VENTILATION OPENINGS SHALL OPEN DIRECTLY TO THE OUTSIDE AIR AND SHALL BE PROTECTED TO PREVENT THE ENTRY OF BIRDS, RODENTS, SNAKES AND OTHER SIMILAR CREATURES. (R806.1) 2. THE MINIMUM NET FREE VENTILATING AREA SHOULD BE 1/150 OF THE AREA OF THE VENTED SPACE, EXCEPT FOR THE PROJECT LOCATED IN CLIMATE ZONE 14 OR 16 WITH A CLASS I OR II VAPOR RETARDER AT THE WARM-IN-WINTER SIDE OF THE CEILING AND WHERE MIN. 40% AND MAX 50% OF THE REQUIRED VENTILATION PROVIDED IN THE UPPER PORTION OF THE ATTIC OR RAFTER SPACE PER SECTION R806.2 THEN THE MINIMUM NET FREE VENTILATING AREA CAN BE 1/300 OF THE VENTED SPACE. (R802.2) 3. PROVIDE 1”SPACE BETWEEN THE INSULATION AND THE ROOF SHEATHING WHERE EAVE OR CORNICE VENTS PROVIDE BLOCKING, BRIDGING AND INSULATION SHALL NOT BLOCK THE FREE FLOW OF AIR. (R806.3) 4. INSTALL VENTILATOR PER MANUFACTURER INSTRUCTION. INSTALL VENTILATOR IN ROOF PER SECTION R903 AND VENTILATOR IN WALL ASSEMBLIES PER SECTION R703.1. 5. FOR THE ATTIC WITH VERTICAL HEIGHT GREATER THAN OR EQUAL TO 30”(VERTICAL HEIGHT MEASURED FROM THE TOP OF CEILING JOIST TO THE BOTTOM OF THE ROOF RAFTERS) WITHIN 30S.F. MIN. PROVIDE THE OPENING WITH ROUGH-FRAMED OPENING OF NOT LESS THAN 22”X30”WHICH SHOULD BE LOCATED IN HALLWAY OR OTHER LOCATION WITH READY ACCESS. IF THE ACCESS LOCATED IN THE WALL THEN THE WIDTH SHOULD BE 22”AND HEIGHT SHOULD BE 30”MIN. IF LOCATED IN CEILING THEN THE MIN. UNOBSTRUCTED HEADROOM IN THE ATTIC SHOULD BE 30”FROM THE BOTTOM OF CEILING JOIST AT SOME POINT. ROOF DRAINAGE: IF THE PROJECT LOCATED IN THE AREA WITH EXPANSIVE OR COLLAPSIBLE SOILS, WATER RUNOFF FROM ROOFS OF ALL DWELLINGS SHALL BE DISCHARGED TO THE GROUND SURFACE NOT LESS THAN 5 FEET FROM FOUNDATION WALLS OR TO AN APPROVED DRAINAGE SYSTEM. (R801.3) -REF.CIVIL DWGS FOR STORM WATER MANAGMENT AND SYSTEM. WEATHER PROTECTION: 1. ROOF DECKS SHALL BE COVERED WITH APPROVED ROOF COVERINGS SECURED TO THE BUILDING OR STRUCTURE IN ACCORDANCE WITH THE CHAPTER 9 OF THE CURRENT CRC. ROOF ASSEMBLIES SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH THE CHAPTER 9 OF CRC AND THE APPROVED MANUFACTURER’S INSTRUCTIONS SUCH THAT THE ROOF ASSEMBLY SHALL SERVE TO PROTECT THE BUILDING OR STRUCTURE. (R903.1) 2. PROVIDE AND INSTALL FLASHING TO PREVENT ENTRY OF MOISTURE TO WALL AND ROOF ASSEMBLIES THRU THE JOINTS IN COPINGS, PERMEABLE MATERIAL, AND AT INTERSECTION WITH PARAPET WALLS AND OTHER PENETRATION THRU ROOF. (R903.2) 3. FLASHINGS SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, WHEREVER THERE IS A CHANGE IN ROOF SLOPE OR DIRECTION AND AROUND ROOF OPENINGS. A FLASHING SHALL BE INSTALLED TO DIVERT THE WATER AWAY FROM WHERE THE EAVE OF A SLOPED ROOF INTERSECTS A VERTICAL SIDEWALL. WHERE FLASHING IS OF METAL, THE METAL SHALL BE CORROSION RESISTANT WITH A THICKNESS OF NOT LESS THAN 0.019 INCH (0.5 MM) (NO. 26 GALVANIZED SHEET). (R903.2.1) 4. A CRICKET OR SADDLE SHALL BE INSTALLED ON THE RIDGE SIDE OF ANY CHIMNEY OR PENETRATION MORE THAN 30 INCHES (762 MM) WIDE AS MEASURED PERPENDICULAR TO THE SLOPE. CRICKET OR SADDLE COVERINGS SHALL BE SHEET METAL OR OF THE SAME MATERIAL AS THE ROOF COVERING. EXCEPT FOR UNIT SKYLIGHTS INSTALLED IN ACCORDANCE WITH HYPERLINK "HTTPS://CODES.ICCSAFE.ORG/LOOKUP/CRC2019P1_PT03_CH03_SECR308.6" SECTION R308.6 AND FLASHED IN ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTIONS SHALL BE PERMITTED TO BE INSTALLED WITHOUT A CRICKET OR SADDLE. (R903.2) 5. PARAPET WALLS SHALL BE PROPERLY COPED WITH NONCOMBUSTIBLE, WEATHERPROOF MATERIALS OF A WIDTH NOT LESS THAN THE THICKNESS OF THE PARAPET WALL. (R903.3) 6. UNLESS ROOFS ARE SLOPED TO DRAIN OVER ROOF EDGES, ROOF DRAINS SHALL BE INSTALLED AT EACH LOW POINT OF THE ROOF. IF WATER CAN BE ENTRAPPED WITHIN THE ROOF AREA THEN SECONDARY EMERGENCY OVERFLOW ROOF DRAINS OR SCUPPERS SHALL BE PROVIDED PER SECTION R903.4.1. (R903.4)