Loading...
HomeMy WebLinkAboutH2022-0521 - Permitsoq City of Newport Beach �aEW e Community Development Department- Building Division 100 Civic Center Drive, Newport Beach, CA 92660 ++ Permit Counter Phone: (949) 644-3288 .' Inspection Requests Phone: (949) 644-3255 C"9C�pnpN�P newportbeachca.gov/inspections Mechanical Permit Plan Check No: Work Class : Other Issued Date : 09/27/2022 Inspection Area :4 H2O22-0521 PERMITS EXPIRE 180 DAYS AFTER ISSUANCE OR LAST VALID INSPECTION, BUT NO LATER THAN 3 YEARS FROM ORIGINAL ISSUANCE DATE NO CONSTRUCTION RELATED NOISE ON SATURDAY OR SUNDAY IN HIGH DENSITY AREAS AND NO WORK ON SUNDAY AND HOLIDAYS IN ALL AREAS Job Address : 1978 PORT NELSON PL Legal Desc : N TR 7028 BILK LOT 34 Description: MECH - R/R FAIL. NEW DUCTS, COIL, A/C CONDENSER, TAMPER -RESISTANT CAP & TIMER REQ'D Owner: PAULAAKERMAN-TOBAN Address : 1978 PORT NELSON PL NEWPORT BEACH, CA 92660 Phone: Applicant: ODETTE LEONELLI Address : 2219A HUNTINGTON LANE Redondo Beach, CA 90278 Phone: (147) 778-8337 Owner/Builder : Address: Phone: Code Edition : 2019 Type of Construction Occupancy Groups: Building Setbacks Flood Zone: Use Zone: PROCESSED BY: Front: 21, Side: 5, Side: 5, Rear: 10 X PC - Harbor View Hills r� !-9»1111F U�U711N]�6y1 Fire Hazard Zone Contractor : ASSOCIATED HEATING & AIR INC Address : 1320 #B N HANCOCK STREET ANAHEIM, CA 92807 Phone : (714) 777-8833 Con State Lic : 608210 Lic Expire : 12/31 /2022 Bus Lic: BT30078570 ON EQUIPMENT Bus Lic Expire:04/30/2023 TIMER REQUIRED Workers' Compensation Insurance 10 P.M. AND 7 A.M. BETWEEN Carrier : TRANSVERS>t(I MT OFF Policy No : FORWC000000249 W. C. Expire: 2/1/2023 NO Manufacturer: ELITE Model#: EL18XCV-036-23DA01 JWNER-BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law forthe reason(s) indicated below by the checkmark(s) I have placed nextto the applicable item(s) 'Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for :he permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of ]Division 3 of the Business and 'rofessions Code) or that he or she is exempt from licensure and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of iot more than five hundred dollars ($500). ❑ 1, as owner of the property, or my employees with wages as their sole compensation, will do (_) all of or U portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner -Builder will have the burden of proving that it was not built or Improved for the purpose of sale). ❑ 1, as owner of the property, am exclusively contracting with licensed Contractors to construct the project (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a licensed Contractor pursuant to the Contractors' State License Law). 1 am exempt from licensure under the Contractors' State License Law for the following reason: By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the improvements covered by this permit, I cannot legally sell a structure that 1 have built as an owner -builder if it has not been constructed in its entirety by licensed contractors. I understand that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request when this application is submitted or at the following Web site:http://www.leginfo.ca.gov/calaw.html. SignatureofProperty Owner or Authorized Agegt, Date I hereby affirm under penalty of pequry diet I'am �1censed under provisions of Chapter 9 (commencing 'th S tion 7000) of Division 3 of the Business tl P ofessions Code, and my license is in full force and effect. 608210 License Class C 20 License No Date Contractor Signature _ WORKERS' COMPENSATION DECLARATION NARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUB.IECT AN EMPLO R T CRIMINAL PENALTIES AND CIVIL FINES uP TO ON HUN RED THOUSAND OOLu s IS166,6061, IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3766 OF THE LABOR CODE INTEREST, AND ATTORNEY'S FEES. I hereby affirm under penalty of perjury one of the following declarations: ❑ I have and will maintain a certificate of consent to self -insure for workers' compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for lh, �Dpe(rfortnance of the work for which this permit is issued.. Polic7 No. WTI have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensatior nsXance carrier and policy number are: Carrier 2.Transverse Ins Co Policy Number FOR-WC-000000249-0 Expiration Date 02.01.2023 Name of Agent nsty Dunlap Phone# UI certify that, in the perform nce of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject tote workers' compensation laws of California, and agre that, if should become,subj t tot orker 'comp anon provisions of Section 3700 of the Labor Code, I shall forthwith comply with those pro sl s. Signature ofAppucant Date 09/26/22 DECLARATION REGARIXNG CONSTRUCTION LENDING AGENCY I hereby affirm underperpkof perjurythat there is a construction lending agency for the performance of the work forwhich this permit is issued ( ec n 3097. Civil Code). Lender's Name Lender's Address By my signature below, I certify to each of the following: I am the property owner or authorized to act on the property owner's behalf. I have read this application and the information I have provided is correct. I agree to comply with all applicable city and cou ordinances and state laws relating to building construction. I authorize representatives of this city or cou h ab e-identified property for inspection purposes. Signature of Property Owner or Authorized Age Print Property Owners or Authorized Agent's Name Odette Leonelli Date 09/26/22 AC77ON DATE BY DECLARATION OF COMPLIANCE MTH CODE OF FOR OFFICE USE ONLY FEDERAL REGULATIONS PART 61 OF T1TLE4L'-AlD AQMD RULE 1403. PERMIT EXPIRED ❑ ISU13MITTEDASBESTOS N)71rIfA7i0N-TO: ❑ EPA ❑ AQMD PERMITCANCELLED PERMIT EXTENDED PROPOSED DEMOLITIOMASBESTOS momf:AnON1SNOTAPPLICA&ETD PERMITFINAL Q$�]� L Oyu CERTIFICATE OF OCCUPANCOSSUED SIGNATURE: CERTIFICATE OF COMPLIANCE Alterations to Space Conditioning Systems (formerly CF-IR-ALT-HVAC) Project Name: Paula Toban Akerman - 1978 Port Nelson PI I Date Prepared: CF1R-ALT-02-E (Page 1 of 3) 2022-09-27 A. General Information CF1R-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one CF1R-ALT-02 document for each dwelling unit. 01 Project Name Paula Toban Akerman - 1978 Port Nelson PI 02 Date Prepared 2022-09-27 03 Project Location 1978 Port Nelson PI 04 Building Type Single family 05 CA City Newport Beach 06 Dwelling Unit Name Paula Toban Akerman - 1978 Port Nelson PI 07 Zip Code 92660 08 Dwelling Unit Conditioned Floor 2480 Area (ft) Number of Space Conditioning 09 Climate Zone 6 10 (SC) Systems in this Dwelling 1 Unit: B. Space Conditioning (SC) System Information 01 02 03 04 05 06 07 08 09 10 SC System ID or SC System CFA served by this Is the SC system a Installing a refrigerant Installing new SC Installing more Installing entirely Installing entirely Name Location or Area 2 SC System (ft) ducted system. containing system than 40 feet of new duct system? new SC system? Alteration Type Served component? components? ducts? Altered space System 1 Location 1 2480 Yes Yes Yes Yes No No conditioning system C. Extension of Existing Duct System, Greater Than 40 Feet (Section150.Z(b)1Diib) This section does not apply to this project. Registration Number: 422-A020151998A-000-000-0000000-0000 Registration Date/Time: 2022-09-27 09:03:39 - HERS Provider: CHEERS NOTICE: This document has been generated by ConSol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards- 2019 Residential Compliance Report Version: 2019.1.006 Report Generated: 2022-09-27 09:13:17 Schema Version: rev 20210501 CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E Alterations to Space Conditioning Systems (formerly CF-IR-ALT-HVAC) (Page 2 of 3) D. Altered Space Conditioning System (Sections 150.2(b)3E and F) 01 02 03 04 05 06 07 08 09 10 11 12 13 SC System Heating Cooling - Description Altered Heating Minimum Altered Cooling Minimum Required New or System ID/ of Area Heating Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency Thermostat Replaced New Duct Name Served System Type Components Type Value System Type Components Type Value Type Duct Length R-Value Central gas All new Central split All new Greater than System 1 Location 1 furnace heating AFUE 0.8 AC cooling SEER 14 Setback 40 feet R-6 components components Required Documentation: CF2R-MCH-01-E -Space Conditioning Systems - Duct insulation requirement for the new portions of supply -air and return -air ducts or plenums: R6 (CZ 1-10, 12 and 13) and R8 (CZ 11 and 14-16) CF2R and CF3R-MCH-20-H - Duct Leakage Test required when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length is replaced -Leakage rate compliance: <= 15 percent or <= 10 percent leakage to outside, or seal all accessible leaks. CF2R and CF3R-MCH-25-H Refrigerant Charge verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15). CF2R and CF3R-MCH-23 Airflow Rate >= 300 CFM per ton required when MCH-25 is required. Exceptions: - Duct systems registered with HERS provider as previously sealed are exempt from MCH-20 Duct Leakage Testing requirements. - Heating -only systems and Air Handler Furnace changes do not require verification of Air Flow MCH-23, or Refrigerant Charge MCH-25. -Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH-20 Duct Leakage Testing requirements. E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)1Diia and 150.2(b)lE, F) This section does not apply to this project. F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C) This section does not apply to this project. Registration Number:422-A020151998A-000-000-0000000-0000 Registration Date/Time: 2022-09-27 09:03:39 HERS Provider: CHEERS NOTICE: This document has been generated by Con Sol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained in this document. CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.006 Report Generated: 2022-09-27 09:13:17 Schema Version: rev 20210501 CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E Alterations to Space Conditioning Systems (formerly CF-IR-ALT-HVAC) (Page 3 of 3) Documentation Author's Declaration Statement 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: CarlosJijon Cav' O-W Company: Signature Date: Associated Heating & Air Inc 2022-09-27 Address: CEA/ HERS Certification Identification (if applicable): 1320 #B N HANCOCK ST City/State/Zip: Phone: ANAHEIM CA 92807 (714) 777-8833 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. S. I will ensure that a registered copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Compliance is required to be included with the documentation the builder providesto the building owner at occupancy. Responsible Designer Name: Responsible Designer Signature: Carlos Jijon CGLY'TUO-VV Company : Date Signed: Associated Heating & Air Inc 2022-09-27 Address: License: 1320 #B N HANCOCK ST 608210 City/State/Zip: Phone: ANAHEIM CA 92807 (714) 777-8833 Digitally signed by censor Home Energy Efficiency Rating System Services, Inc. (CHEERS). This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility Inc the accuracy of the information. Registration Number:422-A020151998A-000-000-0000000-0000 Registration Date/Time: 2022-09-27 09:03:39 HERS Provider: CHEERS NOTICE: This document has been generated by Con Sol Home Energy Efficiency Rating System Services, Inc. (CHEERS) using information uploaded by third parties not affiliated with or related to CHEERS. Therefore, CHEERS is not responsible for, and cannot guarantee, the accuracy or completeness of the information contained In this document. CA Building Energy Efficiency Standards -2019 Residential Compliance Report Version: 2019.1.006 Report Generated: 2022-09-27 09:13:17 Schema Version: rev 20210501