Loading...
HomeMy WebLinkAboutH2017-0310 - PermitsCity of Newport Beach - Building Division III 11111111111111111111111111111111111111111111111 100 Civic Center Drive, Newport Beach, CA 92660 H 2 0 1 7 0 3 1 0 H_ n. Permit Counter Phone (949)644-3288 u �'�tme�x�tt Job Address: 407 VISTA SUERTE BIdg:1 Floor: Suite: Description of Work: MECHANICAL (1) A/C CONDENSER TAMPER RESISTANT CAP REQUIRED Inspector Area:8 Code Edit: 2016 Legal Description: N TR 7148 LOT 18 Owner: SELIM ALAA/HOSNI MAHA Contractor: A C COOL INC Address: 407 VISTA SUERTE Address: P O BOX 7316 NEWPORT BEACH, CA 92660 FULLERTON CA 92834 Phone: Phone: 714-532-2467 Con State Lic: B04056 Issued Date 8/#5l2017 Lic Expire: 01/31/2018 Bus Lic: BT30042073 Processed By. Lic Exp Date: 01/31/2018 MECHANICAL Permit: H2017-0310 Project No Inspection Requests Phone (949)644-3255 Worker's Comp Insurance - Carrier: EVEREST NATIONAL Policy No: 7600007408 Expire :0610112018 C L.r HVAC Items FEES FurnacesBoilers & Compressors Ventilation Other Up to 100K BTU/hr: 0 $0.00 Up to 3HP: 1 $18.00 Bathroom Fan: 0 $0.00 Fire Dampers: 0 $0.00 $0.00 Over 100K BTU/hr: 0 $0.00 > 3 HP to 15 HP: 0 $0.00 Exhaust Fan: 0 $0.00 Gas Line: 0 $0.00 $0.00 Wall/Floor Heaters: 0 $0.00 >15 HP to 30 HP: 0 $0.00 Attic Fan: 0 $0.00 Metal Fireplace: 0 $0.00 Heat Pumps & Package Units >30 HP to 50 HP 0 $0.00 Down -Draft Fan: 0 $0.00 Record Mgt Fee: $0.00 Up to 1OOK BTU/hr: 0 $0.00 >50 HP: 0 $0.00 Residential Hood: 0 $0.00 Additional Fee : $37.50 Investigation: $0.00 Over 500K BTU/hr: 0 $0.00 Air Handling Units Comm. Hood: 0 $0.00 Plan Check: $15.66 Up to 1 M BTU/hr: 0 $0.00 up to 1 OK CFM: 0 $0.00 Repair/Alter/Add: 0 $0.00 Model: 24AHA4-36 Issuance: $33.00 Up to 1.75M BTU/hr: 0 $0.00 Over 10K CFM: 0 $0.00 Supplemental Fee: $0.00 Manufacturer: CARRIER Over 1.75M BTU/hr: 0 $0.00 VAV Box: 0 $0.00 TOTAL: $104.16 Plan Check Fee : $0.00 Fee Due at Permit Issuance : $104.16 PERMITS EXPIRE 180 DAYS AFTER ISSUANCE OR LAST VALID INSPECTION Construction Hours: Monday - Friday 7:00 a.m.to 6:30 p.m.and Saturday from 8:00 a.m. to 6:00 p.m. enFCTOWS ELECTRICAL METAL JC TUBING SUBREVI W AND CT TO APPROVAL HERS VERIFICATION REQ (EMTIIS NOT ALLOWED FOR EXTERIOR APPLICATIONS TION I he: affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the reason(s) indicated below by the checkmark(s) I have placed next to the applicable item(s) (Section-7031.5.- bi-siness and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and F rofassiuns Code) or that he or she is exempt from licensure and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hund^ed dollars ($500). EI ;, as, owner of the p,operty, or my employees with wages as their sole compensation, will do (_) all of or U portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and P,c'rss'ons Code: The Contractors' State License Law does not apply to an owner of property who, through employees' or personal effort, builds or improves the property, provided that the improvements a,e not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner -Builder will have the burden of proving that it was not built or ilna-.avid for the purpose of sale). I. as owner of the property, am exclusively contracting with licensed Contractors to construct the project (Section 7044, Business and Professions Code: The Contractors' State License Law does not Lpply to an ownai uf-pr9perty who builds or improves thereon, and who contracts for the projects with a licensed Contractor pursuant to the Contractors' State License Law). C i aln exempt from licensure under the Contractors' State License Law for the following reason: % my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the improvements covered by this permit, I cannot legally sell a structure that I have built as an owner -builder if it has no n c nstruct in its entirety by licensed contractors. I understand that a copy of the applicable law, Section 7044 of the Business and Professions Code, is available upon request wh n is app' ati i mi �t the following Web site:http://www.leginfo.ca.gov/calaw.htmi. Signature of Property Owner or Authorized Agent�-�-� Da LICENSED CONTRACTOR'S DECLARAT ONE I hereby affirm under penalty of perjury that I am licensed under provisions of Chapt 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. License Class License No Date Contractor Signature WORKERS' COMPENSATION DECLARATION WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. I hereby affirm under penalty of perjury one of the following declarations: ❑ I have and will maintain a certificate of consent to self -insure for workers' compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the rmanceof the work for which this permit is issued. Policy No. Dlave and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensatior rt ence, carrier and policy number are: Policy Number Date ne of Agent Phone # certify that, in the performance of the w k for which thi rmit is is ed, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree t, if I should becoKAR bject to tI ork c sa on rows s f Section 3700 of the Labor Code, I shall forthwith comply with those provisions. nature of Applica�� Da CLARATION REN CONSTRU TION L NDING AGENC !reby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Section 306, 'Civil/code). Ider's Name Lender's Address my signature below, I certify to each of the following: I am the property owner or authorized to act on the property owner's behalf. I have read this application and the information I have provided is correct. I agree to comply with all applicable city and county ordii 5ie I s relating to building construction. I authorize representatives of this city or co my to e t€r ve party for inspection purposes. g I� �� nature of Property Owner or Authorized A e Print Property Owner's or Authorized Agent's Name X o e L A C U D 41 I S 7 ACTION DATE ' BY DECLARATION OF COMPLIANCE WITH CODE OF FOR OFFICE USE ONLY FEDERAL REGULATIONS PART 61 OF TIRE 40 AND AQMD RULE 1403. PERMITEXPIRED- -- r -- ❑ I SUBMITTED ASBESTOS NOTIFICATION TO: ❑ EPA ❑ AQMD PERMITCANCELLED _ PERMITEXTFNDED' ...- - - -. ❑ ASBESTOS NOTIRCATIONIS NOT APPLICABLE TO PROPOSED DEMOLITION. SIGNATURE: PERMITFINAL .- .,,11/O9II$ ACcq. CERTIFICATEOF i OCCUPANCYISSUED CERTIFICATE OF COMPLIANCE Alterations to Space Conditioning Systems (formerly CF-IR-ALT-HVAC) Project Name: Maha Hosni I Date Prepared: CFIR-ALT-02-E (Page 1 of 3 ) 2017-06-12 A. General Information CF1R-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit, When multiple dwelling units must be documented, use one CF1R-ALT-02 document for each dwelling unit. 01 Project Name Maha Hosni 02 Date Prepared 2017-06-12 03 Project Location 407 Vista Suerte 04 Building Type Single family 05 CA City Newport Beach 06 Dwelling Unit Name Maha Hosni 07 Zip Code 92660 08 Dwelling Unit Conditioned 2122 Floor Area (ft2) Number of space conditioning 09 Climate Zone 6 10 (SC) systems in this dwelling 1 unit. B. Space Conditioning (SC) System Information 01 02 03 04 05 06 07 08 09 10 Is the SC Installing a SC System SC System CFA served system a refrigerant Installing new SC Installing Installing Installing Identification or Location or Area by this SC ducted containing system more than 40 entirely new entirely new Name Served System (ft2) system? component? components? feet of ducts? duct system? SC system? Alteration Type System 1 Location 1 2122 Yes Yes Yes No No No Altered space conditioning system C. Extension of Existing Duct System, Greater Than 40 Feet (Section 150.2(b)iDiib) This section does not apply to this project. Registration Number: 217-A0197648A-000000000-0000 Registration Date/Time: 2017-06-12 14:53:49 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2013 Rev 1.008 Report Generated: 2017-06-12 14:54:10 Schema Version: 0.555SDD CERTIFICATE OF COMPLIANCE CFIR-ALT-02-E Alterations to Space Conditioning Systems (formerly CF-IR-ALT-HVAC) (Page 2 of 3 ) D. Altered Space Conditioning System (Sections 150.2(b)lE and F) 01 02 03 04 05 06 07 08 09 10 11 12 Heating Cooling System Heating Altered Heating Minimum Altered Cooling Minimum Required New or Identification System Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency Thermostat Replaced New Duct or Name Type Components Type Value System Type Components Type Value Type Duct Length R-Value Central gas No heating This field or This field or Cen tral split All new Less than or System 1 furnace component section is not section is not AC cooling SEER 14 Setback equal to 40 R-6 altered applicable applicable components feet Required Documentation CF2R-MCH-01-E -Space Conditioning Systems Ducts and Fans -Duct insulation requirement for new plenums: R6. CF211-10CH-20-1­1 & CF3R-MCH-20-H — Duct Leakage testing required when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length is replaced. -Leakage rate compliance: < 15%, or s 10% leakage to outside, or seal all accessible leaks. CF2R-MCH-25-H & CF3R-MCH-25-H Refrigerant Charge Verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15). CF2RCF3R-MCH-23 & CF3R-MCH-23 Air Flow 2 300 CFM/ton required when MCH-25 Is required. Exceptions: -Duct systems registered with HERS provider as previously sealed are exempt from MCH-20 Duct Leakage Testing requirements. -Heating-only systems and Air Handler/Furnace changes do not require verification of Air Flow MCH-23, or Refrigerant Charge MECH-25. -Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH-20 Duct Leakage Testing requirements. E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)1Diia and 150.2(b)lE, F) This section does not apply to this project. F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)IC) This section does not apply to this project. Registration Number: 217-A0197648A-000000000-0000 Registration Date/Time: 2017-06-12 14:53:49 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2013 Rev 1.008 Report Generated: 2017-06-12 14:54:10 Schema Version: 0.555SDD CERTIFICATE OF COMPLIANCE CFIR-ALT-02-E Alterations to Space Conditioning Systems (formerly CF-SR-ALT-HVAC) (Page 3 of 3 ) Documentation Author's Declaration Statement 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: y DelVaglio,-Paul �/� �// C1G•YA.G oe (/CLUCI.O� gad O Company: Signature Date: A C COOL INC 2017-06-12 14:53:49 Address: CEA/ HERS Certification Identification (if applicable): P.O. Box 6868 City/State/Zip: Phone: Orange CA 92863 949-720-3938 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a registered copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Responsible Designer Signature: ry-� o DelVaglio, Paul V"CZGLG Company: Date Signed: A C COOL INC 2017-06-12 14:53:49 Address: License: P.O. Box 6868 804056 City/State/Zip: Phone: Orange CA 92863 949-720-3938 Easy to Verify at CaICERTS.com Digitally signed by CaICERTS, This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Providerresponsibility f r the accuracy of the inform Registration Number: 217-AO19764BA-000000000-0000 Registration Date/Time: 2017-06-12 14:53:49 HERS Provider: CaICERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2013 Rev 1.008 Report Generated: 2017-06-12 14:54:10 Schema Version: 0.555SDD