HomeMy WebLinkAbout20130516_Home Elevator Manufacters Specs
Planning
MACHINE
ROOMLESS
TRACTION
DRIVE
950 lb.
AMERICA’S MOST CUSTOMIZABLE ELEVATOR
Guide
INCLINATOR LX®
MACHINE ROOMLESS TRACTION DRIVE
4 LX - MRL TRACTION DRIVE
Hoistway Layout
The following specs are to be provided by the General Contractor (GC), except as
noted, prior to Elevator Contractor (EC) installing the elevator equipment.
1. Enclosed, plumb and square hoistway with smooth interior surfaces.
Include for fascias or furring of hoistway interior.
2. Doors, frames and door hardware.
3. Finish openings as per elevator contractor’s shop drawings.
4. Hoistway door security: All hoistway doors require door locking devices (provided by
Inclinator) as well as a door handle and a latch set. All doors must be swing type
(single hinge). Solid core doors are recommended.
5. Unfinished/Un-installed door: EC may prefer a minimum of one hoistway door and
associated framing be left unfinished to accommodate elevator installation and
prevent possible damage to door/framing. Preferably at the lowest floor.
2 LX - MRL TRACTION DRIVE
Introduction
It started over 85 years ago with a passion to help an ailing friend
access his multi-level home. Now, almost a century later, the Inclinator
craftsmanship can be found in more American homes today than any
other brand. We want to use our heritage of service to enhance each
stage of your building or remodeling experience and to help you create
a uniquely personalized elevator for your home.
Of all the stages, none is quite as exciting as the initial design phase.
It’s where you begin to imagine the possibilities of something that’s
uniquely yours. A home is personalized by the components you
choose to fit your needs.
Our Planning Guide is designed to simplify and assist architects,
contractors, home owners and dealers in planning for a home elevator
that meets the requirements of ASME A17.1
We recommend you contact an authorized dealer in the area where
the elevator will be installed. They will be knowledgeable about local
codes and restrictions. Become familiar with all requirements
governing the installation and use of elevators in private residences. It
is extremely important for you to know and adhere to all regulations
concerning installation.
This Planning Guide provides nominal dimensions and specifications
useful for the initial planning of an elevator project. Before beginning
actual construction, be sure to contact a local authorized dealer and
obtain approval drawings customized with specifications and
dimensions for your specific project. Call 1-800-343-9007 to find a
local dealer or visit our website, www.inclinator.com. Inclinator
elevators manufactured and installed under the proper parameters are
warranted for 2 years. We assume no liability for equipment not
installed in compliance with national, state, and local codes.
LX - MRL TRACTION DRIVE 3
Table of Contents
Hoistway Layout ............................................... 4-8
Hoistway Construction ........................................ 9
Hoistway Specifications .................................... 10
Hoistway Elevation ............................................ 11
Pit Specifications ............................................... 12
Technical Specifications .................................... 12
Controller Space ............................................... 13
Warranty ............................................................ 14
Steps of planning for an Inclinator LX Elevator
1. Locate local dealer and together determine the following:
a. Select a drive system, cab type and design specifications
b. Address national, state and local code requirements
c. Determine installation parameters of site
2. Obtain approval drawings before building hoistway, doorways,
pit, and any other construction related to the elevator
3. Coordinate with dealer to order and install the elevator
LX - MRL TRACTION DRIVE 5
Hoistway Layout
The following data is for typical industry size elevators.
Any size cab is available in ¼” increments to dimensions A and C or B and D
within the maximum and minimum dimensions shown in the diagram on
page 4 not to exceed 15 SQ. FT.
- Applicable to standard size wheelchairs
\
CODE 1
CODE 2
CODE 3
6 LX - MRL TRACTION DRIVE
Hoistway Layout
The following data is for typical industry size elevators.
Any size cab is available in ¼” increments to dimensions A and C or B and D
within the maximum and minimum dimensions shown in the diagram on
page 4 not to exceed 15 SQ. FT.
CODE 4
CODE 5
CODE 6
LX - MRL TRACTION DRIVE 7
Hoistway Layout
CODE 4,5
CODE 3,6
CODE 5,1
CODE 5,2
8 LX - MRL TRACTION DRIVE
Hoistway Layout
ADDITIONAL CONFIGURATIONS
There are many additional layout options available. Please contact Inclinator or your local dealer for
further assistance on shaft configurations.
LX - MRL TRACTION DRIVE 9
Hoistway Construction
5-3 RULE / DOOR FRAME DETAILS
RAIL DETAILS
SUPPORT WALL DETAIL
NOTE:
* FRAMING ON DOOR SIDE OF HOISTWAY MUST BE OF 2x4 CONSTRUCTION
TO APPLY TO 5-3 RULE OF ANSI 17.1 CODE.
NOTE:
WHEN STUD AND SHEETROCK CONSTRUCTION IS USED ON THE
RAIL BRACKET SUPPORT WALL, DBL 2x6 STUDDING IS NEEDED
TO MOUNT THE RAIL BRACKETS. DO NOT USE METAL STUDS.
DOOR SILLS TO BE INSTALLED BY GC AFTER THE LIFT
SUPPLIER HAS INSTALLED A RUNNING PLATFORM. SILL
MUST BE BROUGHT OUT TO NOT LESS THAN ½” AND NOT
MORE THAN 1 ¼” TO THE RUNNING PLATFORM WHILE
MAINTAINING A DISTANCE OF 3” FROM THE HOISTWAY
FACE OF THE LANDING DOOR (OR GATE) TO THE
HOISTWAY EDGE OF THE LANDING SILL.
10 LX - MRL TRACTION DRIVE
Hoistway Specifications
The following specs are to be provided by the General Contractor (GC), except as noted, prior to
Elevator Contractor (EC) installing the elevator equipment.
1. Environmental requirements for hoistway:
a. Temperature should be maintained between 400 F to 1000 F.
b. Should not be exposed to the elements.
2. Pit Requirements:
a. Substantial level pit floor slab to support 3,123 lbs. impact load.
b. Waterproof pit minimum 8” below lowest floor level,
unless buffer springs are required then minimum 12” pit required.
3. Overhead Requirements:
a. If minimum 8’6” OH is not possible, consult Inclinator, or EC, about possible solutions.
4. Rail Support Wall Requirements:
a. The support wall consists of a double 2” x 6” bonded & nailed planking that is
then constructed within a typical wood 2” x 4” studded wall. These double 2” x
6” planks are oriented and mounted perpendicular to the standard wall
construction, all of these must be installed plumb and straight.
b. The dual steel “T” rail assembly provided by Inclinator is to be mounted to the
double stud planking plumb and straight along the vertical plane.
c. The rail brackets are secured to the double 2” x 6” planking with ½” x 4” lag
bolts, see drawing details.
d. All studs in the rail support wall must be of wood, typical steel studs are
prohibited and cannot be used in the rail support wall.
e. Consult factory or dealer for concrete or steel framed construction.
5. ASME 17.1 Part 5.3: Hoistway to be constructed in accordance with this code and all local
codes. It is the responsibility of the GC and the EC to comply with all appropriate codes.
LX - MRL TRACTION DRIVE 11
Hoistway Elevation
12 LX - MRL TRACTION DRIVE
Pit Specifications
Rail Reactions
LX - MRL TRACTION DRIVE 13
Controller Space
1. Permanent 230 volt, single phase, 30 amp dedicated circuit to operate the
elevator.
2. 120 volt lighting supply and disconnect by others.
3. Telephone connection: Code requires a telephone connection. A phone line
must be installed leading to the controller.
4. Recommended maximum distance from controller to hoistway box is 10’.
5. N.E.C. Regulations
a. Minimum 30” x 36” clear unobstructed floor space in front of controller.
14 LX - MRL TRACTION DRIVE
Warranty
This warranty and all implied warranties including the implied warranties
of merchantability and fitness for a particular purpose, for this product
are limited to a period of two years from the time this product is first
installed.
Some states do not allow limitations on how long an implied warranty
lasts, so the above limitation may not apply to you.
The manufacturer is not responsible for consequential damages resulting
from the use of this product, including labor charges for removal and
reinstallation of parts. The manufacturer’s liability for any damages
resulting from use of this product or breach of this or any implied
warranties is limited solely to parts, repair or replacement in accordance
with the terms set forth above and these are the exclusive remedies
available to purchasers of this product.
Some states do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitation or exclusion may not
apply to you.
LX - MRL TRACTION DRIVE 15
16 LX - MRL TRACTION DRIVE
601 Gibson Blvd, Harrisburg, PA 17104 | 800-343-9007 | www.INCLINATOR.com
LX MRL TRACTION PLANNIG GUIDE – 02/05/2012