HomeMy WebLinkAbout2019-04-12_Photometric Study Compiled JAGAR ARCHITECTURE tel. +1.310.391.7646 email info@jagar.co web www.jagar.co address 6210 Wilshire Blvd. Suite 209, Los Angeles CA 90048 USA 2902 West Coast Highway Project Photometric Impact Analysis Jagar Architecture prepared a photometric analysis for the 2902 West Coast Highway restaurant project (“Project”). The photometric analysis considered all sources of light at the Project, the intensity of lighting sources based upon manufacturer specifications, and physical features of the existing environment and buildings. The analysis demonstrated that lighting associated with the Project would be minimal at the building boundary, which is located more than 350 feet from the nearest residential receptor. All new sources of lighting will comply with Newport Beach Municipal Code Section 21.30.070, which requires that all outdoor lighting fixtures be designed, aimed, located, and maintained to shield adjacent properties from light spillage. All lighting will also comply with California Building Code and other applicable standards. The Project Site is located in a highly developed, well-established commercial area of Newport Beach. The surrounding area is characterized by a variety of sources of ambient lighting common to urban, developed areas, including commercial uses, street lighting, and vehicle lights. For instance, the Project Site fronts on West Coast Highway, a major thoroughfare in the City, and a source of substantial ambient light. A significant number of the commercial uses in the area continue into the evening and early morning hours, thus contributing ambient light during normal sleeping hours. The Project Site is also located within an existing commercial development, which has current light sources, and located more than 350 feet from the nearest residential receptor. The photometric study determined that exterior lighting would generate light as follows: 1. Ground Floor Exterior: 2. Outdoor Terrace: JAGAR ARCHITECTURE tel. +1.310.391.7646 email info@jagar.co web www.jagar.co address 6210 Wilshire Blvd. Suite 209, Los Angeles CA 90048 USA The Project’s light will not impact nearby residential uses. Outdoor Terrace lighting would produce light of 4.8 foot-candles1 at the edge of the Outdoor Terrace. Accounting for the distance to the nearest residential receptor to the Outdoor Terrace (approximately 400 feet), 4.8 foot-candles would reduce to 0 foot-candles at the residential receptor property line. This reduction does not account for intervening structures. Ground Floor Exterior lighting would be a maximum of 6.4 foot-candles at the boundary of the Project Site. The nearest residential receptor is located more than 350 feet from the Project Site boundary, and light from the Ground Floor Exterior would reduce to 0 foot-candles due solely to distance. For purposes of comparison, 0.5 foot-candle is equivalent to 50% of the amount of light emitted from a single wax candle from one foot away. The Project’s lighting will not impact residential uses because the light generated will not be intrusive or trespass onto residential property. The City of Newport Beach does not have a generally applicable light trespass standard. The City of Los Angeles, however, regulates light trespass and provides that no exterior light may cause more than 2.0 foot-candles of lighting intensity onto any residential property.2 The illuminance calculation data in the tables above demonstrate that any light trespass associated with the Project’s Ground Floor Exterior and Outdoor Terrace lighting is well below the standard of 2.0 foot-candles at the nearest residential receptor. The City of Santa Ana similarly limits light trespass on sensitive receptors. The Santa Ana Citywide Design Guidelines provide that commercial site lighting should not exceed more than 5.0 foot- candles within 50 feet of a property used as or zoned residential.3 The Project’s lighting would be 0 at 50 feet from the nearest residential receptor, which is below the City of Santa Ana standard. Based upon the foregoing, the Project would not generate light that would cause lighting impacts at nearby residential receptors. 323497603.2 1 Illuminance measures the amount of illumination (i.e., luminous flux) that falls on a given area from a light source. Luminous flux is defined as the mean value of total candelas produced by a light source, and describes the total amount of light emitted by a light source. The unit for measuring luminous flux is a lumen. Illuminance is measured in foot-candles (lumen per square foot, or the light energy within one square foot surface). Illuminance decreases with the square of the distance from the light source. 2 Los Angeles Municipal Code Section 93.0117(b). 3 City of Santa Ana Citywide Design Guidelines, Chapter 9 – Commercial Design Guidelines, p. 9-19. L-001 L-001 L-001 L-001 L-002 L-002 L-002 L-002 L-002 L-002 L-002 L-002 L-002 L-002 L-002 L-002 L-002 L-002 L-002 L-002 L-002 L-002 L-019L-019L-019L-019L-019 L-019 L-019 L-008 LED TAPE 2 LAYERS (STACKED VERTICALLY) ON BOTTLE SHELVING +/-65' L-006 LED TAPE BELOW COUNTER +/- 56' L-007 LED TAPE BELOW COUNTER +/-52' L-008 L-006 L-006 L- 0 0 6 L- 0 0 6 L-007 L-007 L- 0 0 7 L- 0 0 7 L-006 L-007 L-020L-020 L-021 L-021 L-021 L-021 L-021 L-021 L-021 L-021 L-021L-021 L-021 L-021L-021 L-021 L-021 L-021 L-021 L-021 L-021 L-021 L-021 L-021 L-021 L-021 L-002 L-024 L-024 L-024 L-024L-024 L-024 PLANTER L-008 L- 0 0 8 L- 0 0 8 L-024 H-001 L-021 L-021 L-021 L-021 L-021 L-021 L-021 L-021 L-021 L-021 L-021 L-001 L-001 L-001 L-001 L-001 L-001L-001L-001 L-001 L-001 L-001 L-001 L-001 L-001 L-001 L-001 L-001 L-022 L-022 L-022 L-022 L-002 L-002 L-002 L-002 L-002 L-002 L-002 L-002 L-002 L-002 L-002 L-020 L-020 L-027 L-027 L-027L-027 L-027 L-027 L-027 L-027 L-027 L-027 L-027 L-027 L-027 L-027 L-027 L-027 L-027 L-027 L-027 L-027 L-027 L-027 L-027 L-027 L-027 L-027 L-027L-027 L-024 L-024 L-024 L-024L-024L-024 L-002 L-002 L-002 EXIT L-002 L-002 L-002 L-002 EX I T L-035 L-0 3 5 B B B B B BB B BB BB B B B B B B BB BBBBBBBBBB B B B B B B B B B B B B B B B B B B B B B B B B B B B DN DN 0.9 1.2 1.5 1.7 1.6 1.6 1.5 1.6 1.4 1.2 1.0 1.5 2.1 2.7 3.2 3.0 2.9 2.8 3.0 2.6 2.2 1.8 2.6 3.7 4.8 5.9 5.4 5.3 5.0 5.4 4.5 3.9 3.4 3.6 5.1 7.1 9.1 6.9 7.3 7.0 8.2 6.9 6.7 6.4 4.5 6.1 8.2 7.5 6.6 8.4 9.2 9.2 5.9 7.7 8.7 9.0 8.1 8.6 9.1 8.6 7.4 9.0 10.1 10.4 9.2 8.7 7.4 6.4 11.2 12.7 12.1 11.4 9.1 8.4 7.0 5.4 14.9 16.2 13.4 11.6 8.1 7.4 6.0 4.6 13.2 14.2 11.8 10.3 6.9 6.3 5.2 4.1 8.1 9.5 9.5 8.1 6.1 6.5 5.2 3.9 5.0 6.4 8.0 10.1 8.1 8.6 8.9 9.7 7.3 5.0 3.5 3.9 5.1 6.2 7.3 7.1 7.4 7.8 8.4 7.0 5.1 3.6 3.6 4.4 5.0 5.5 5.4 5.9 7.0 7.1 6.8 5.6 4.1 3.2 4.0 4.8 5.2 5.4 6.1 7.8 8.9 8.2 6.4 4.5 3.0 4.1 5.4 6.8 7.1 7.6 10.4 12.7 10.5 6.9 4.5 2.7 3.9 6.1 8.7 8.9 8.7 12.1 14.9 11.5 6.8 4.0 3.1 4.3 6.0 8.0 7.9 7.5 9.4 11.0 8.5 5.0 2.9 3.5 4.7 5.4 5.8 5.5 5.2 5.6 5.9 4.8 3.1 1.9 3.2 4.3 4.4 4.7 4.3 3.9 3.6 3.3 2.7 1.9 1.2 3.3 4.4 4.9 5.2 5.0 4.2 3.2 2.4 1.8 0.9 0.7 2.7 4.0 5.7 7.8 8.4 6.5 4.1 2.5 1.6 2.5 4.4 8.0 12.9 14.5 10.2 5.5 2.9 1.6 2.7 5.2 10.6 18.1 19.7 13.1 6.7 3.3 1.7 2.8 5.5 11.3 19.5 21.4 14.2 7.2 3.4 1.7 2.7 5.0 9.8 16.9 19.6 13.7 7.0 3.3 1.7 2.8 4.5 7.7 12.7 15.2 11.1 5.8 2.9 1.5 3.2 4.3 5.8 8.0 9.1 7.1 4.1 2.3 1.4 3.2 3.7 4.4 4.8 4.9 4.1 2.9 1.9 1.3 3.7 4.2 3.9 3.4 3.3 3.1 2.5 2.1 1.6 3.7 4.2 3.7 3.1 3.1 3.3 2.7 2.5 2.1 3.1 3.5 3.1 2.9 3.0 3.3 1.9 1.7 1.6 1.3 2.4 1.2 2.4 1.3 2.6 1.1 1.9 1.3 2.0 1.5 1.9 2.3 2.6 3.9 4.3 5.3 5.4 6.1 6.5 6.8 7.3 6.7 7.1 6.6 6.7 6.9 7.3 6.9 7.4 6.3 6.4 6.3 6.5 5.8 5.8 4.8 4.7 14.6 15.9 16.8 17.4 17.6 17.4 16.8 15.9 14.7 16.4 17.8 18.9 19.5 19.8 19.6 18.9 17.9 16.4 18.0 19.6 20.8 21.5 21.9 21.6 20.8 19.6 18.0 19.4 21.1 22.5 23.3 23.7 23.3 22.4 21.1 19.3 20.5 22.5 23.9 24.8 25.2 24.8 23.9 22.4 20.5 21.5 23.5 25.0 26.0 26.4 26.0 25.0 23.4 21.3 22.2 24.3 25.9 26.9 27.3 26.8 25.8 24.1 21.9 22.6 24.8 26.5 27.4 27.8 27.3 26.3 24.5 22.2 22.8 25.0 26.8 27.7 28.1 27.6 26.4 24.6 22.3 22.8 25.0 26.7 27.7 28.1 27.5 26.3 24.5 22.2 22.5 24.7 26.4 27.3 27.7 27.0 25.8 24.0 21.7 22.1 24.1 25.6 26.6 26.9 26.3 25.0 23.1 21.0 21.3 23.2 24.7 25.5 25.7 25.1 23.9 22.1 19.9 20.2 22.0 23.4 24.2 24.2 23.6 22.5 20.7 18.6 18.9 20.6 21.9 22.4 22.5 21.8 20.8 19.1 17.2 17.4 18.9 20.0 20.5 20.5 19.9 18.8 17.4 15.6 15.7 17.1 18.0 18.4 18.4 17.8 16.8 15.5 14.0 14.0 15.1 15.8 16.2 16.2 15.7 14.8 13.7 12.3 LIGHTING SCHEDULE TAG SYM QTY.WATTSDESCRIPTION LAMP SMALL INGROUND UPLIGHT 1"L-001 12 1W LED MEDIUM INGROUND UPLIGHT 3"L-002 35 3W LED WALL SCONCEL-003 32 4W LED UPLIGHT SCONCE ON BARL-004 12 10W LED L-005 L-006 12 LARGE PENDANT LIGHT CORRIDOR L-007 20 7.5W LED 5" LED CAN LIGHT L-008 20 26W LED2'X2' LED TROFFER KITCHEN W LED4W/FTLED TAPE LIGHTING TYP. 01 ART+/-70' LFT L-009 7 EMERGENCY LIGHT CEILING W LED3W/FTLED TAPE LIGHTING TYP. 02 BAR+/-130' LFT W LEDLED TAPE LIGHTING TYP. 03+/-121' LFT W LEDLED TAPE LIGHTING TYP. 04+/-237' LFT L-010 L-011 L-012 L-013 SMALL PENDANT LIGHT DINING28 PENDANT LIGHT STAIRS16 L-014 L-015 INT. BAR PENDANT LIGHT L-017 L-018 L-016 WALL SCONCE VANITIES LED TAPE LIGHTING TYP. 05 14 9 13 +/-113' LFT RECESSED LED ADJUSTABLE ROOFTOP DECORATIVE EXTERIOR SCONCE7 40W LEDL-019 L-020 L-021 L-022 L-023 L-024 6 2W EXTERIOR SCONCE ROOFTOP BAR TRELLIS PENDANT LIGHT ROOFTOP BAR PENDANT LIGHT 36 4 13 MANUF.MODEL #FINISHES AND REMARKS 5" LED CAN LIGHT - STORAGE L-025 8 L-026 L-027 DIRECTABLE LED LIGHT SPOT ON ART INT DINING PENDANT LIGHT BACKROOM EXTERIOR RECESSED LIGHT L-028 +/-80' LFT LED TAPE LIGHTING TYP. 06 STAIRS L-029 5" LED CAN LIGHT MAIN RESTROOMS L-030 LARGE DINING PENDANT LIGHT L-031 L-032 LED TAPE LIGHTING TYP. 07+/-90' LFT 5" LED CAN LIGHT - EMERGENCYL-031E LED ROOFTOP BATHROOM EXIT EXIT SIGN 13 42 1 9 14 23 15 L-033 4 DIRECTABLE LED LIGHT - ROOF KITCH. WAC WAC 1021 1" 5032 3" HUDSON VALLEY WAC ELITE DURA LAMP BOCA SILOX10 2010 LB103 DURTAPE ES INSTALL UPSIDE DOWN BEAM 35", BLACK FINISH 3W/FTDURA LAMP DURTAPE ES 3W/FTDURA LAMP DURTAPE ES MITZI RES. HARDWARE TECH LIGHTING ORACLE EELP ELITE MITZI DURA LAMP RESTOR. HARDWARE EMILIA H126701-PB 4W 3.5W 24W 3.5W 18W 4W VINTAGE FRENCH FARMHOUSE PENDANT QUINTON PENDANT OT-LED 2X2 FEB ER3-SHAL-ADJ-LED EMILIA H126101-PB CANNELE OUTDOORSINGLE SCONCE WEATHERED ZINC LED SMOKE COLOR FL. TECH LIGHTING QUINTON PENDANT LED SMOKE COLOR 900 LUMENSLED LED W LED3W/FTDURTAPE ES WAC 4011 CITIZEN F5993 ER3-SHAL-ADJ-LED CYLINDER CY2 TROY LIGHTING ELITE LUCIFER RECTANGLE STEP LIGHTS 12V - ROOFTOP BRONZE ON BRASS 7.5W LED LED 21W LED 10W LED 3W LED 21W LED 21W LED 21W LED 4W LED LED 3W LED RESTOR. HARDWARE CANNELE OUTDOOR SINGLE SCONCE 40W CITIZEN F5993TROY LIGHTING 7.5W LED TECH LIGHTING 3.5WQUINTON PENDANT LED SMOKE COLOR DURA LAMP GEM STARBURST CHANDELIERLUMENS HH4-LED 4"ELITE/MAXILUME ELX-606MAXILUME W LED3W/FTDURTAPE ES ER3-SHAL-LEDELITE TRIMLESS SQUARE HH4-LED 4"ELITE/MAXILUME EMERGENCY MODE DURA LAMP W LED3W/FTDURTAPE ES ER3-SHAL-ADJ-LEDELITE 21W LSL10 AGAVEAURORALIGHT 12VAC; BLP EXTRA DARK 27W LEDHH4-LED 4"ELITE/MAXILUME FLUSH MOUNT L-001B L-002B MEDIUM INGROUND UPLIGHT 3"33 3W LEDWAC5032 3" SMALL INGROUND UPLIGHT 1"21 1W LEDWAC1021 1" 9-15VAC 9-15VAC L-034 4 EXITL-035 EXIT SIGN SURFACE MOUNT3WLEDELX-607MAXILUME5 PROPOSED LIGHTING - OUTDOOR DINING TERRACE - PHOTOMETRICS ROOF DINING TERRACE PHOTOMETRICS1SC: 3/16" = 1' LIGHTING SCHEDULE3SC: NTS NTS SHEET NUMBER DATE DRAWN BY SCALE PROJECT TENANT TITLE REVISIONS PROJECT NAME GARDEN NEWPORT RESTAURANT 2902 WCH 2018-04_ GARDEN_ NEWPORT FEBRUARY 8, 2019 NO.ISSUE DATE JAGAR ARCHITECTURE 11900 JEFFERSON BLVD LOS ANGELES, CA 90230 TEL: (310) 391 7646 E-MAIL: INFO@JAGAR.CO WEB: WWW.JAGAR.CO DESIGNER OWNER / LANDLORD CONSULTANTS SK-190 STATISTICS2SC: NTS SOUTH-EAST VIEW4SC: NTS NORTH-WEST VIEW5SC: NTS NORTH-EAST VIEW6SC: NTS "BAR" CALCULATION ZONE CALCULATION ZONE WORKPLANE AT FINISHED FLOOR "ROOF" CALCULATION ZONE CALCULATION ZONE WORKPLANE AT FINISHED FLOOR M010 M010 UP UP UP EL-01 EL-06 EL-02 EL-01 EL-01 EL-01 EL-01 EL-01 EL-01 EL-01 EL-01 EL-01 EL-01 EL-01 EL-01 EL-01 EL-01 EL-01 EL-01 EL-01 EL-01 EL-01 EL-01 EL-02 EL-02 EL-02 EL-02 EL-02 EL-02 EL-02 EL-02 EL-02 EL-02 EL-02 EL-02 EL-02EL-02 EL-02 EL-02 EL-02 EL-02 EL-02EL-02 EL-02 EL-02 EL-02 EL-02 EL-02 EL-02 EL-02 EL-02 EL-02 EL-02 EL-02EL-02 EL-03 EL-03 EL-03 EL-03 EL-03 EL-03 EL-03 EL-04 EL-04 EL-04 EL-04 EL-04 EL-04 EL-04 EL-04 EL-04 EL-04 EL-04 EL-04 EL-04 EL-04 EL-04 EL-04 EL-04 EL-04 EL-04 EL-04 EL-04 EL-04 EL-04 EL-04 EL-04 EL-04 EL-04 EL-04EL-04 EL-04 EL-04 EL-02 EL-02 EL-02 EL-06 EL-06 EL-06 EL-06 EL-06 EL-06 EL-06 EL-06 EL-06 EL-06 EL-06 EL-06 EL-06 EL-06 EL-06 EL-06 EL-06 EL-06 EL-06 EL-06 EL-06 EL-06 EL-06 EL-06 EL-06 EL-06 EL-06 EL-06 EL-06 EL-06 EL-06 EL-06 EL-06 EL-06 EL-06 EL-06 EL-06 EL-07 EL-07 EL-06EL-06EL-06EL-06EL-06EL-06EL-06EL-06 EL-06 EL-06 EL-08EL-07 EL-08 EL-08 EL-08 EL-08 EL-08 EL-08 EL-08 EL-08 3.8 3.4 2.7 2.5 0.0 0.0 0.0 0.0 0.0 0.0 0.0 2.3 2.5 1.9 1.1 0.7 7.2 7.3 3.4 3.6 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 3.6 2.7 1.5 0.8 10.8 9.0 0.0 0.0 5.6 12.4 0.0 0.0 11.7 9.5 0.0 0.0 8.0 6.8 0.0 0.0 5.4 4.1 0.0 0.0 4.4 3.5 0.0 0.0 6.9 5.1 0.0 0.0 10.7 8.6 0.0 0.0 13.9 13.8 0.0 0.0 13.9 14.0 0.0 0.0 11.3 9.1 0.0 0.0 6.9 5.6 0.0 0.0 4.4 3.4 0.0 0.0 5.1 3.9 0.0 0.0 7.7 6.1 0.0 0.0 11.3 9.2 0.0 0.0 11.8 12.3 0.0 0.0 10.9 10.8 0.0 0.0 7.4 6.2 0.0 0.0 4.7 3.3 0.0 0.0 3.3 2.4 0.0 0.0 5.4 3.5 0.0 0.0 8.0 6.4 0.0 0.0 11.0 8.5 0.0 0.0 4.4 11.3 0.0 0.0 9.9 7.6 0.0 0.0 6.4 5.5 0.0 0.0 4.7 3.6 0.0 0.0 4.9 4.3 0.0 0.0 8.1 6.8 0.0 0.0 11.5 9.4 0.0 0.0 13.7 13.1 0.0 0.0 12.9 13.7 3.8 3.3 3.4 0.0 0.0 10.8 9.8 6.2 5.3 5.6 0.0 0.0 7.5 8.3 8.2 8.1 8.3 0.0 0.0 5.9 7.7 9.5 10.0 9.7 0.0 0.0 6.7 9.0 10.7 10.7 9.5 0.0 0.0 8.6 10.5 11.3 10.2 8.3 0.0 0.0 13.3 14.3 11.6 9.1 6.7 0.0 0.0 18.5 16.5 12.3 7.3 5.1 0.0 0.0 12.7 16.1 10.3 5.6 3.7 0.0 0.0 3.6 2.6 0.0 0.0 2.3 1.8 0.0 0.0 1.4 1.2 0.0 0.0 1.0 0.8 0.0 0.0 0.7 0.6 0.0 0.0 0.5 0.4 0.0 0.0 0.3 0.3 0.4 0.4 0.4 0.4 0.3 0.0 0.0 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.0 0.0 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.0 0.0 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.0 0.0 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.0 0.0 0.1 0.1 0.2 0.2 0.7 1.7 1.8 0.0 0.0 0.1 0.1 0.2 0.4 2.2 3.7 3.9 0.0 0.0 0.1 0.1 0.2 0.9 2.9 6.3 6.5 0.0 0.0 0.1 0.1 0.1 0.6 2.5 5.1 5.6 0.0 0.0 0.1 0.1 0.1 0.2 2.7 4.7 4.9 0.0 0.0 0.1 0.1 0.1 0.7 2.7 5.5 5.9 0.0 0.0 0.1 0.1 0.1 0.8 2.9 6.1 6.3 0.0 0.0 0.1 0.1 0.1 0.3 2.1 4.0 4.2 0.0 0.0 0.1 0.1 0.1 0.2 2.1 4.0 4.2 0.0 0.0 0.1 0.1 0.1 0.8 2.7 5.7 6.1 0.0 0.0 0.1 0.1 0.1 0.8 2.8 5.9 6.3 0.0 0.0 0.1 0.1 0.2 0.3 2.7 4.8 5.1 0.0 0.0 0.1 0.1 0.2 0.5 2.5 5.0 5.3 0.0 0.0 0.1 0.1 0.1 0.9 3.0 6.3 6.5 0.0 0.0 0.1 0.1 0.1 0.5 2.4 4.2 4.5 0.0 0.0 0.1 0.1 0.1 0.2 1.0 2.1 2.1 0.1 0.0 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.3 0.2 0.2 0.1 0.2 0.1 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.6 1.6 1.6 0.0 0.0 0.0 0.1 0.1 0.1 0.4 2.1 3.5 3.7 0.0 0.0 0.0 0.1 0.1 0.1 0.9 2.9 6.2 6.4 0.0 0.0 0.0 0.0 0.1 0.1 0.6 2.5 5.2 5.7 0.0 0.0 0.0 0.0 0.1 0.1 0.2 2.7 4.6 4.8 0.0 0.0 0.0 0.0 0.1 0.1 0.6 2.6 5.3 5.7 0.0 0.0 0.0 0.0 0.1 0.1 0.8 2.9 6.2 6.4 0.0 0.0 0.0 0.0 0.1 0.1 0.3 2.4 4.7 5.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 2.4 4.7 4.9 0.0 0.0 0.0 0.0 0.1 0.1 0.8 2.8 6.1 6.5 0.0 0.0 0.0 0.0 0.1 0.1 0.6 2.5 5.1 6.5 5.7 6.4 5.2 4.6 5.1 5.5 3.0 1.1 0.0 0.0 0.0 0. 0. 0. 0. 1. 2. 3. 4. 6. 6. 5. 6. 6. 3. 1. 0. 0. 0. EXTERIORLIGHTINGPHOTOMETRICS EXT. LIGHTING SCHEDULE 1 NTS NTS SHEET NUMBER DATE DRAWN BY SCALE PROJECT TENANT TITLE REVISIONS PROJECT NAME GARDEN NEWPORT RESTAURANT 2902 WCH 2018-04_ GARDEN_ NEWPORT FEBRUARY 8, 2019 NO.ISSUE DATE JAGAR ARCHITECTURE 11900 JEFFERSON BLVD LOS ANGELES, CA 90230 TEL: (310) 391 7646 E-MAIL: INFO@JAGAR.CO WEB: WWW.JAGAR.CO DESIGNER OWNER / LANDLORD CONSULTANTS SK-186 EXTERIOR LIGHTING PHOTOMETRICS2SC: 1/8" = 1' STATISTICS3SC: NTS 10'-0" AFF 8'-0" AFF 8'-0" AFF 8'-0" AFF SOUTH CORNER ELEVATION (PARTIAL)4 SC: NTS SOUTH-EAST CORNER ELEVATION (PARTIAL)5 SC: NTS 0 0 0 0 1 0 5 0 4 0 0 0 0 0 0 0 0