HomeMy WebLinkAboutXR2025-0468 - Alternative Material & MethodsCITY OF NEWPORT BEACH COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 100 Civic Center Drive I P.O. Box 1768 1 Newport Beach, CA 92658-8915 www.newportbeachca.gov 1 (949) 644-3200 CASE NO.: ❑ REQUEST FOR MODIFICATION TO PROVISIONS OF TITLE 9 (FIRE CODE) OR TITLE 15 (BUILDING CODE) OF THE NEWPORT BEACH MUNICIPAL CODE (See Reverse for Basis for Approval) (Fee $316) ® REQUEST FOR ALTERNATE MATERIAL OR METHOD OF CONSTRUCTION (See Reverse for Basis for Approval) (Fee $316) For above requests, complete Sections 1, 2 & 3 below by printing in ink or typing. M RECEIVED BY COMMUNITY DEVELOPMENT MAY 0 8 2025 CITY OF NEWPORT BEACH III FOR STAFF USE ONLY III Plan Check # W 9 ,! — OYM of Stories 2 Occupancy Classification Az3 a Use of Building SFD # of Units / Project Status Pf�a [.w Construction Type V43 r!5?r Verified by No. of Items .. Fee due q 3/IV DISTRIBUTION: Owner FPlan Check 0' A' Petitioner r I Inspector Fire ❑ Other 1 I JOB ADDRESS: PETITIONER: SITE ADDRESS: 1927 Port Bristol Circle Petitioner Denise Xagorarakis Owner Fredy Catota (Petitioner to be architect or engineer) 1441 W 244th St. Address 17900 Skypark Cir. Ste. 102 Address Harbor City Zip 90710 Irvine, CA Zip 92614 Daytime Phone ( 323 ) 617-0742 Daytime Phone (949) 422-4364 Email: denisenxagdesigns.com 2 REQUEST: Submit plans if necessary to illustrate request. Additional sheets or data may be attached. To rovitle less than the code required clear distance from the 1 exterior finish grade to the underside of the wood sill plate of the new exterior walls and r71 externr finished arade or finished surface to the weep screed. TION/FINDINGS OF EQUIVALENCY: 2022 CRC R317.1, R703.7.2.1 The continuous bituthene and copper or stainless steel flashing provides equivalent protection form penetration of moisture to the building as the minimum vertical separation between the too of the building concrete and the exterior surface prescribed in the building code. Position Architect Petitioner's 05/06/2025 Siqnature CA Professional Lic. # C37154 Date: III FOR STAFF USE ONLY III DEPARTMENT ACTION: In accordance with: `gCBC 104.11/CFC 104.9 ❑ CBC 104.10/CFC 104.8 (Alternate materials & methods) (CBC Modification) ❑ Concurrence from Fire Code Official is required. ❑ Approved ❑ Disapproved ❑ Written Comments Attached By: Request (DOES),(DOES NOT) lessen any fire protection requirements. bequest (DOE (DOES NOT) lessen the structural integrity Date I The Request is: ranted ❑ Denied (See reverse for appeal information) I Granted (Ratification required) Conditions of Position CHIEF BUILDING OFFICIAL Date Print Name APPEAL OF DIVISION ACTION TO THE BUILDING BOARD OF APPEALS (See Reverse) (Signature, statement of owner or applicant, statement of reasons for appeal and filing fees are required.) CASHIER RECEIPT NUMBER: RED -00S644 7015 Forms\mod[f 07/29/24 Guidelines for Approval of Alternate Materials, Design and Methods of Construction Basis For Approval For the Chief Building Official and Fire Code Official or their designated agent to approve a request for modification or a request for alternate material or method of construction, he/she must determine that special, individual reasons exist that make compliance with the strict letter of the Code impractical and that equivalency is provided. The resulting condition must be in conformance with the spirit and purpose of the Code provisions involved and that such modification does not lessen fire protection, structural integrity or occupant safety. The applicant must provide sufficient information with this application to allow the above evaluation to be made. Requirements for Submittals The applicant design professional shall prepare a Written Report that describes the alternate proposal along with the applicable data listed below: • State specific code provisions for which alternative is requested and why request is being submitted. • Describe by code section those provisions for which alternative is desired. • Compare the proposed alternative versus the code requirements in terms of structural strength, suitability, effectiveness, fire resistance, safety and health impacts affecting the building or user of the building. • Demonstrate that the proposed alternative is compatible with balance of code requirements. • When applicable, specify how authoritative consensus document(s) are used to substantiate proposal. (Reference draft ]CC Building Performance Code Commentary Section 1.4.2.3 for background information). • Provide assumptions, references, and documentation of evaluation methods utilized. This includes intended use, input data, anticipated outputs, and limitations of computer models and other analytical tools or methods. • Specify when and where special inspection and testing are required and the standards of acceptance for demonstrating compliance. Show how the proposed alternate, if accepted, will be identified on the job site. • Where land use restrictions and building setbacks are required, deed restrictions may be an appropriate method to ensure continued compliance. • State how and where alternate proposal is incorporated within construction plans and prepare plan amendments as necessary. The design professional has the responsibility to coordinate all construction documents and ensure compatibility between documents. • The report and design documents shall be dated, signed and stamped by the design professional according to the plan submittal procedure. • For alternate methods of design requests, the applicant shall set performance criteria for his design. Performance criteria shall be reviewed, amended and approved by the Building or Fire Code Official prior to start of design. Alternative Design Review/Verif!cation The Chief Building Official or Fire Code Official has the responsibility to review design submittals for compliance to the adopted codes and procedures. If the Building or Fire Code Official does not have the expertise on staff to make a thorough and competent review, the Building or Fire Code Official shall select a consultant that possesses the necessary qualifications to perform a third -party or peer review. Cost of peer review shall be paid by applicant to the Building Division prior to commencing the review. • Verify that all applicable information and justifications listed above as requirements for submittals is received and verify that evaluation and design methods used by designer are appropriate to the alternative proposed. • Verify products are being used in accordance with their listing conditions as required by recognized listing agencies. If not available, require documentation and/or testing to demonstrate compliance with intent of code and intended use. • Evaluate performance of material and possible flaws that could affect performance of material in its installed state. • The reviewer shall document that the submittal has been reviewed and accepted as meeting the alternative materials, design and methods of construction provisions of the code. If the Building or Fire Code Official is not satisfied that the applicant has met the conditions, the request should be denied in writing with the applicable reason(s). Inspection/Field Verification The alternate proposal as approved in the construction documents must be verified by inspection, and, where necessary, testing as follows: • To verify that alternate materials, systems and fabricated products comply with accepted design criteria and the manufacturer's and engineer's installation procedures, inspectors should check product labeling, certification, quality assurance processes, and testing, as applicable. • When appropriate, an approved third party quality assurance inspection and testing service may be required for continuous and complex inspection and testing activities. This is intended to verify that construction complies with the code and the approved plans. Appeal from the determination or action of the Chief Building Official or Fire Code Official or their designated agent may be made to the Building and Fire Board of Appeals. To appeal, the applicant must provide special individual reasons that make compliance with the strict letter of the Code impractical. Appeals or ratifications pertaining to State Disabled Access Standards require complete evidence to substantiate that the proposed design is equivalent to that prescribed by that standards or that due to legal or physical constraints, compliance with the standards or providing equivalency would create an unreasonable hardship. Appeals must be submitted on the Appeal Form available at Permit Counter accompanied by the proper fee. You will be notified in writing of the appeal hearing's time and date. STUCCO WITH CORROSION RESISTANT METAL LATH CORR. RESIT. LATH 0/ BLDG. PAPER. PROVIDE POSITIVE LAP 0/ FOUNDATION EDGE AT BOTTOM VERTICAL SIDING PRESERV. TREATED SILL PLATE — <8" ABV GRADE. (CRCR317.1) BUILDING PAPER 0/ CORR. RESIST. METAL FLASHING 0/ METAL BASE SCREED WITH WEEP HOLES PER CODE REQUIREMENTS N CV M CONCRETE WALK SL 1/4:12 CONTINUOUS S.S. OR COPPER FLASHING OVER BITUTHENE MOISTURE BARRIER. BOTH EXTEND 6" BELOW TOP OF CONCRETE STEM WALL. EXTEND MOISTURE BARRIER 18" ABV. FLOOR SHEATHING AND FLASHING 6" ABV. FLOOR SHEATHING. FLEXIBLE SEALANT 2X FRAMING W�-110110 J W m ce Z LL T.O.C. 0 In n °n VERIFY AL,t MIN. ° 3 CLEAR. DIM WI FIN. ° ATANU6. REQ. AT SLAB Zo v OR 1" MIN. ° ° a ° z ° ALT. METHOD OF SCREED - STUCCO / SIDING SCALE: N.T.S. I- x a c DESIGNS m ;gym PORT BRISTOL RESIDENCE `MSKYP PARK CIR, STE 1@ 1927 PORT BRISTOL CIRCLE DNTKY P IRVINE, CALIFORNIA OW14 9.mgd l NEWPORT BEACH_ CA 9266n LESS THAN 718" MIN. EXT. 2"VEN E�_R 314",MIN.INT. 2X BUILDING PAPER 01 CORROSION RESISTANT METAL FLASHING 01 C.R. METAL BASE SCREED NATURAL STONE VENEER TO BE ADHERED TO WALL PER CRC R703.12 & IN ACCORD. W/ MANUF'S INSTRUCTIONS. REFER TO TABLE R703.8(2) FOR MAX WEIGHT & VENEER WEIGHT. 2X BACKING PRESERV. TREATED SILL PLATE <8" ABV GRADE. (CRCR317.1) 1/8" CORR. RESIST. STEEL, LSHAPE, W/ WEEP HOLES PER CODE REQ. - CONT. W/ LAG SCREWS @ 16" O.C. CONCRETE WALK SL 114:12 CONTINUOUS S.S. OR COPPER FLASHING OVER BITUTHENE MOISTURE BARRIER. BOTH EXTEND 6" BELOW TOP OF CONCRETE STEM WALL. EXTEND MOISTURE BARRIER 18" ABV. FLOOR SHEATHING AND FLASHING 6" ABV. FLOOR SHEATHING. FLEXIBLE SEALANT /*zcu - C37154 5-3'1 2X FRAMING 0 SHEATHING PER z STRUCT.DWGS x m z VERIFY ALL MIN. a CLEARANCE z_ z_ DIMENSIONS Wl =n SIDINGo m > MANUFACTURER'S REQUIREMENTSAT z d 2" I SLAB OR 1"MIN. q J m ° UO io n a ° 4 o ° d Z m a o ° ° z o ° US,° m o a ° z °° ALT. METHOD OF SCREED - STONE VENEER SCALE: N.T.S. XAG DESIGNS �� a m PORT BRISTOL RESIDENCE °900SKYNF°' 1927 PORT BRISTOL CIRCLE CONTS PARK CIR 5>E 104 IRVINF, CAUFORNK92614 s 2a �.�m NEWPORT BEACH_ CA 92660