HomeMy WebLinkAbout35 MOON SHELL - SOILSQ
Qom\
SOILS ENGINEERING, INC.
Consulting Geotechnical Engineers
Standard Pacific Homes
15326 Alton Parkway
Irvine, California 92618
k C �� -C i� , -
�
s
2860 WALNUT AVE. HILL, CALIF. 90755 - PHONE 562/426-7990 - FAX 562/426-1842
.0 VS Ott
0"�—l\�\p \V\yIt Do
PpQ�\ c�pS�.O r1
vQpa N-e-X,1
Attention: Mr. Sean Doyle
Subject: Geotechnical Review of Pro osed
Tides Project, County of Orang ,
References: See Attached List
Ladies and Gentlemen:
June 18, 2008
Project No. 06-15175
/New Pool, Lot 23, Tract 15918, The
lifornia
This report presents a review of the proposed new rear yard pool on Lot 23, Tract
15918 by Associated Soils Engineering, Inc. (ASE). The Landscape Improvement Plans
for the site were prepared by Summers/Murphy & Partners, Inc., dated May 29, 2008
and enclosed herein as Plate 1.
POOL DESIGN AND CONSTRUCTION
Associated Soils Engineering, Inc. (ASE) has reviewed the Landscape Improvement
Plans for the subject proposed site with respect to design parameters for the proposed
pool. In previous conversations with the client as well as the structural engineer, it has
been brought to the attention of ASE that the proposed pool can accept differential
settlement no greater than 3/8 inches over a distance of 40 feet. Based on a review of
the Rough Grading Report by Goffman, McCormick & Urban, Inc, (GMU), the proposed
pool is underlain by between roughly 30 to 45 feet of compacted fill below pad grade.
The estimated approximate depth to bedrock for selected portions of the pool is shown
on Plate 1,
The proposed plan is considered suitable for the intended use from a geotechnical
viewpoint. Based upon the test results from the previous reports, materials exhibiting
"Medium" to "High" expansion potential per 2007 CBC are present at the proposed
foundation locations. Sulfate resistant concrete is required as the test results indicate
"Severe" sulfate exposure per ACI 318. The following recommendations specific to the
pool construction should be incorporated in the design.
Updated Seismic Design Criteria
The 2007 CBC seismic design criteria for the site were determined utilizing the Java
Ground Motion Parameter Calculator -- Version 5.0.8 available from the Seismic Design
Values for Buildings webpage on the website of Earthquake Hazard Program of U.S.
Geological Survey (http://earthguake.usgs._qov/research/hazmaps/design). A summary
of the seismic coefficients is presented in the following table, as well as the design
response spectra attached as Figure 1:
2007 CBC SEISMIC DESIGN PARAMETERS
Site Latitude:
N 33.5769°
Site Longitude:
W 117.83330
Seismic Parameter
Recommended Value
Site Class a
D
Soil Profile Name b
stiff soil profile
Site Coefficient, Fa °
1.0
Site Coefficient, F„ d
1.5
0. Second Spectral Response Acceleration,
1.723 g
11.0-Second Spectral Response Acceleration,.
0.629 g
Adjusted 0.2-Second Spectral Response
Acceleration, Sens s
1.723 g
Adjusted 1.0-Second Spectral Response
Acceleration, Sm, b
0,944 g
Design 0.2-Second Spectral Response
Acceleration, Sos
1.149 g
Design 1.0-Second Spectral Response
Acceleration, Soy
0.629 g
(ccupancji Category
_.
I or 11
III
IV
Seismic Design Category based on Sos k
D
D
D
Seismic Design Category based on SoII I
D
D
D
a Per 2007 CBC Table 1613.5.2
b Per 2007 CBC Table 1613.5,2
c Per Java Ground Motion Parameter Calculator
from USGS website. Also shown on 2007 CBC
Table 1613.5.3 (1).
d Per Java Ground Motion Parameter Calculator
- from USGS website. Also shown on 2007 CBC
Table 1613.5.3 (2).
e Per Java Ground Motion Parameter Calculator
from USGS website. Also shown on 2007 CBC
Figure 1613.5 (1).
` f Per Java Ground Motion Parameter Calculator
from USGS website. Also shown on 2007 CBC
JFigure 1613.5 (2).
v� Standard Pacific Homes
Project No. 06-15175
:l
SOILS ENGINEERING, INC.
g SMs=FaxSs
h SMI = Fv x SI
i
SDS = 2/3 x SMs
1
SDI = 2/3 x SMI
k Per 2007 CBC Table 1613.5.6 (1). Also refer to
2007 CBC Section 1613.5.6 for special conditions.
Per 2007 CBC Table 1613.5.6 (2). Also refer to
2007 CBC Section 1613.5.6 for special conditions.
June 18, 2008
Page 2
Recommendations
1. Due -to the low tolerance for differential settlement as described by the structural
engineer, all of the pools should be supported by end -bearing caissons founded
a minimum of five fe t into undistur ed bedrock. The caissons should be tied
together with grade beams to entirely support the pool shell.
2. End -bearing caissons should be designed with an allowable bearing value of
3000 pounds per square foot per foot of embedment into bedrock, to a maximum
of 15,000 psf. Based on the generally "Medium" to "High" expansion potential of
the site soils, potential slope creep should be anticipated within the outer
approximately 10 feet of the slope face (measured horizontally). The portion of
the caissons within the creep zone should be designed to resist active earth
pressures of 40 pcf with no consideration of passive lateral resistance in front for
the portion of the caisson within the creep zone. All end -bearing caissons should
be spaced no closer than four (4) caisson diameters on centers to alleviate
potential group effect. Utilizing a 2'-0" diameter caisson belled out to a T-0"
diameter at the base is suitable from a geotechnical viewpoint.
3. Due to the generally "Medium" to "High" expansion potential of the site soils, pool
and spa walls should be designed to resist an equivalent fluid pressure of 90 pcf
and should be designed to be capable of supporting water without lateral soil
support.
4. Hydrostatic relief valves should be incorporated into the pool and spa design.
5. All fittings and pipe joints, particularly those in the side of the pool or spa, should
be properly sealed to prevent water from leaking into the underlying soils. A
poorly designed, installed or maintained waterproofing system could lead to
excessive soil expansion/movement upon occurrence of leakage.
6. An elastic waterproof expansion joint should be installed to prevent water from
seeping into the soil at all deck joints.
7. The caisson excavations should be observed by the geotechnical consultant to
ensure that the minimum depth of bedrock penetration has been achieved
suitable for support of the pool. All foundation excavations should be observed by
the Geotechnical Consultant's representative to verify minimum embedment
depths and competency of bearing soils prior to placement of forms and
reinforcement.
8. All other pertinent recommendations regarding site grading and foundation
design and construction stipulated in the referenced report remain applicable.
(J �o
Standard Pacific Homes
Project No. 06-15175
SOILS ENGINEERING, INC.
June 18, 2008
Page 3
Pool Plans & Structural Calculations
The plans and calculations should be provided to ASE to ensure that the structural
design engineer utilizes the soil parameters presented herein and in the referenced
reports for the design of the caisson foundations.
This opportunity to be of service is sincerely appreciated. If you have any questions
regarding the information in this report or other geotechnical aspects of the project,
please contact Associated Soils Engineering, Inc.
Respectfully submitted,
ASSOCIATED SOILS
Edward .(Ted) ifl
Engineering Geolo
ECR/LC/tr
��� �IVG, INC.
0
J. RiDCELL
No.1775 T1
CER-fIFIED
e�NOINEr-.FIINCa
E-0L0cl�r
� N177
Lawrence J.D. Char
Civil Engineer, RCE
Enclosure: Figure 1 — Design Response Spectra
Plate 1 — Pool Plan
Distribution: (5) Addressee
4a
Standard Pacific Homes
Project No. 06-15175
SOILS ENGINEERING, INC.
e�pFESS/off
� by y
4
LU 67987 G) m
P. 6 o%v 1 M
OF CA1-�Fo�
June 18, 2008
Page 4
LIST OF REFERENCES
1. Associated Soils Engineering, Inc., 2006, Response to the County of Orange
Planning and Development Services Department (OCPDSD) - Grading Section
Geotechnical Report Review Sheet dated TSeptember
es Mode115ite,0County of Orange,
Revision
1, Tract 15918, Lots 1 through ,
California
2. Associated Soils Engineering, Inc., 2006, Review of Model Site Precise Grading
Plan, Latest Revision 1, Lots 1 through 5, Tract 15918, "The Tides" Project,
Crystal Cove, County of Orange, California, Project No. 04-5712, dated August 9.
3. Associated Soils Engineering, Inc., 2006, Review of Pool Plans and Structural
Calculations for the Proposed Model Site on Lots 1 through 3, Tract 15918, "The
Tides" Project, Crystal Cove, County of Orange, California, Project No. 06-15175,
dated October 23.
4, Associated Soils Engineering, Inc., 2006, Supplemental Review of Precise
Grading Plan Lots 1 through 5, Tract 15918, "The Tides" Project, Crystal Cove,
County of Orange, California, Project No. 06-15175, dated September 25.
5. Associated Soils Engineering, Inc., 2005, Precise Grading Plan Review, Lots 6
through 30, Tract 15918, "The Tides" Production, Crystal Cove Area, County, of
Orange, California, Project No. 05-5712, dated November 7.
6. Associated Soils Engineering, Inc., 2005, Response to the County Orange
on
Planning and Development Services Department (OCPDSD) -
Grading
Geotechnical Report Review Sheet dated February 3, 2006, Lots 1 through 5,
Tract 15918, Crystal Cove III, County of Orange, California, Project No. 05-5712,
dated February 23.
7. Goffman, McCormick & Urban, Inc., 2003, Response to County of Orange
Geotechnical Report Review Sheet, Report of Geotechnical Observation and
Testing of Rough Grading, Lower Merchant Site - Lots 1 through 59, and the
Recreation Site, Tract 15918, Tentative Tract 15613, Crystal Cove, Newport
Beach, Orange County, California, Project No. 01-27-20, dated November 14.
8. Goffman, McCormick & Urban, Inc., 2003, Report of Geotechnical Observation
and Testing of Rough Grading, Lower Merchant Site - Lots 1 through 59, and the
Recreation Site, Tract 15918, Tentative Tract Map 115613, Crystal Cove,
Newport Beach, Orange County, California, Project No. 01-27-20, dated
September 11.
_J �a
. Standard Pacific Homes
�o3 Project No. 06-15175
SOILS ENGINEERING, INC.
June 18, 2008
Page 5
. - k .
ZERO EDGE
COPING
SA9EMENT LEVEL PAVING
SCALE: tf8' • 1'A1
APPROXIMATE DEPTH OF FILL (FT) w
J
Thev
I I oro i
Sumi
bc,
a q'
duN'
I � proy
Detr
Mur
I
.1 IIL
` APERTY
TNmr4G WALL
RECIROXATING TROUCN
ASSOCIATED SOILS ENGINEERING,
LaN
INC.2860 WALNUTAVENUE
SIGNAL HILL, CA 90756
Ph: (562) 426.7090
PLAN REVIEW
I5175 Date; g_7$_0$ Plate; 1
NORT 1 0 S 16 24 32
J1.UARM! tPlMOtj Ir1C
�T1 gf�NAT. aurtfaa
Tiw� fN NBPl1�M}'If11
�alC�AAF
Y 1p
9T OFCAItf�
dMIM91 ontl/or the
nponylnq sped kaltons
k evctwWl Dropedy of
H Murphy & arinerk.
d lase a+d DuNf-
Mall bf bP tl Ihk to lay
al ells for whkh they
Dn 'I" celkn *"'-
>d, In whole or pal. is
btlad ocot 4y wrlllen
Eselon from S�mmerf/
shy & Poa—s, Inc.
OF