Loading...
HomeMy WebLinkAbout35 DEL MAR - MISCDAVID A. PURKIS, PE Consulting Civil Engineer November 28, 2006 Project No. 06-1993 TO: Drilco, Inc. PO Box 945 Laguna Beach, CA 92652-0945 SUBJECT: Response to the County of Orange "Arch. and Struct. — Commercial Plan Check Corrections"; dated November 22, 2006 for 35 Del Mar, Newport Coast, California (RW060698) REFERENCE: 1. David A. Purkis, PE; March 6, 2006; "Structural Analysis of Temporary Shoring & Combined Permanent Retaining Wall, 35 Del Mar, Newport Coast, California" Dear Drilco; In response to the Items of the subject correction list (attached) we offer the following: 11.2 Site Plan by others. 4.6 Requested note is on Sheet RW-1. 5.7 Soil report to be provided by others. 10.9 Grading Plan by others. 12.10 Notes added to RW-I. 13.11 Requested callouts added to RW-1. Thank you for the opportunity to be of service. If you have any questions, please call. 7Re fully Submitted, David A. Purkis, PE Civil Engineer (RCE 42810) Expires 3-31-08 32158 Camino Capistrano #212, San Juan Capistrano, CA 92675 • 949.240.7293 . Fax 949.661.1562 RWQ60698 -Arch. and Struct.-Commercial Plan Check Corrections Retaining Wall c0.1 In your responses, please refer to the alpha -numeric reference numbers that are shown at the start of each of the followingcorrection items. 01.2 Retaining wall permit will be issued after Grading permit has been issued. We have sent a copy of your plans to the Grading inspector for field evaluation. Upon Grading inspector's report, you may be required to obtain Grading permit. c7.3 Site plan shall be stamped and wet signed by Civil Engineer. Landscape Architect stamp and signature is not acceptable. c6.4 This Retaining wall permit is for the construction of the retaining walls that are not part of the house structural system. �► c9.5 The Building Permit is issued to owners and licensed contractors. Agents must show an authorization letter that has been notarized by a public notary. �► n r c4.6 Please note on TitleSheet, "Construction Plans and Calculations shall comply with all of the requirements of the California Building Code 2001 Edition." �► c5.7 Provide a soil report to justify parameters used in retaining wall design calculations. 0 9 Page 5 of 5 c8.8 Soil report shall be approved by the Grading Section prior to permit issuance. 00.9 These retaining walls shall be shown on the approved Grading Plan. Please provide. If this Grading plan does not show these retaining walls, please revise to show walls and resubmit. NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM 02.10 Include "National Pollutant Discharge Elimination System Notes" on first sheet of plans. (This information is provided in the beginning of this document) Item 1 shall be filled out on plans. 03.11 Provide Erosion and Sediment Control(ESCP) plan or show on the Site PLan the locations iseperatSandbag Barriers_ p____er SE_8 and C.encrete Washout Area Per WIV1 8. This submittal Is seperate from grading submittal. 11/22/2006 12:03 PM = Indicates line item not Cleared. Z. Fagih Z. Fagih Z. Fagih Z. Fagih Z. Fagih Z. Fagih Z. Fagih Z. Fagih Z. Fagih Z. Fagih Z. Fagih