Loading...
HomeMy WebLinkAboutCSP R51 Parcel #459-185-03 3049 East Coast Hwy, Corona Del Mar, CA Comprehensive Sign Plan 2 Table of Contents 1. Title Page 2. Table of contents 3. General Sign Requirements 4. Sign Matrix Calculation 5. Overall Site Plan 6. Sign Site Plan 7. Elevations 8. Sign A1 9. Sign A2 10. Sign B1 11. Sign B2 12. Pylon Reface 3 General Sign Construction Requirements 1. All signs and their installation shall comply with all local building and electrical codes. 2. All electrical signs will be fabricated by a U.L. approved sign company, according to U.L. specifications and bear U.L. Label. 3. Sign company to be fully licensed with the City and State and shall have full Workman's Compensation and general liability insurance. 4. All penetrations of building exterior surfaces are to be sealed waterproof in color and finish to match existing exterior. 5. Internal illumination to be LED and to contain all UL certified components. 6. Painted surfaces to have a satin finish. Only paint containing acrylic polyurethane products may be used. 7. Logo and letter heights shall be as specified and shall be determined by measuring the normal capital letter of a type font exclusive of swashes, ascenders, and descenders. Ascenders & descenders are allowed. 8. All sign fabrication work shall be of excellent quality. All logo images and type-styles shall be accurately reproduced. Lettering that approximates typestyles will not be acceptable. The Landlord reserves the right to reject any fabrication work deemed to be below standard. 9. All lighting must match the exact specification of the approved working drawings. No exposed conduits will be allowed. Raceways will be allowed for wall signs on brick facades, in which case the raceway must be painted to match the facade and is subject to landlord approval. The brace for a canopy installed sign may also be considered a raceway and must be painted to match the canopy on which it is installed. 10. Signs must be made of durable rust –inhibiting materials that are appropriate and complimentary to the building. 11. Color coatings shall exactly match the colors specified on the approved plans. 12. Joining of materials (e.g., seams) shall be finished in way as to be unnoticeable. Visible welds shall be continuous and ground smooth. Rivets, screws, and other fasteners that extend to visible surfaces shall be flush, filled, and finished so as to be unnoticeable. 13. Finished surfaces of metal shall be free from oil canning and warping. All sign finishes shall be free from dust, orange peel, drips, and runs and shall have a uniform surface conforming to the highest standards of the industry. 14. In no case shall any manufacturer’s label be visible from the street from normal viewing angles. 1. Each Tenant shall submit to Landlord for written approval, three (3) copies of the detailed shop drawings of this proposed sign, indicating conformance with the sign criteria herein outlined. 2. The Landlord shall determine and approve the availability and position of a Tenant name on any ground sign(s). 3. The Tenant shall pay for all signs, related materials and installation fees (including final inspection costs). 4. The Tenant shall obtain all necessary permits. 5. The Tenant shall be responsible for fulfillment of all requirements of this sign criteria. 6. It is the responsibility of the Tenant’s sign company to verify all conduit and transformer locations and service access prior to fabrication. 7. Should a sign be removed, it is the Tenant's responsibility to patch all holes, paint surface to match the existing color, and restore surface to original condition. Landlord / Tenant Requirements 4 5 (E) Pylon Sign 6 Major Tenant Signs: A1, A2 Minor Tenant Signs: B1 - B2 Major Tenant Minor Tenant Sign A1 Sign B1 Sign B2 Sign A2 7 Sign A1Sign B1 Sign B2 Sign A2 7 8 Ø1/2" SLEEVE ANCHOR (Ø3/8" BOLT), 2" MINIMUM EMBEDMENT CMU, BRICK Ø3/8" EXPANSION ANCHOR, 2 1/2" MINIMUM EMBEDMENT PRE-CAST CONCRETE, CONCRETE Ø3/8" LAG BOLT, 3" MINIMUM EMBEDMENT WOOD BLOCKING Ø3/8" THREADED ROD EIFS WALL w/ FOAM INSULATION Ø3/8" THREADED ROD w/ALUMINUM OR PVC COMPRESSION SLEEVE WOOD, CONCRETE BLOCK, EIFS WALL SYSTEMS SECTION ANCHOR TYPE WALL TYPE Ø3/8" PIVOTING TOGGLE BOLT 5/8" THICK MIN. PLYWOOD Mounting Options Scale: N.T.S. Typical Section - Face Lit Letter - Flush Mounted & Self Contained Scale: N.T.S.B ALUMINUM RETURN PAN HEAD SCREW TRIM CAP WELD-ON 16 & RESIN BONDOR CHANNEL BOND CHANNEL LOCK OR RIVET ECONOLITE SHEET ALUMINUM BACK / LED MODULE 3/16" THICK PLASTIC FACE Ø5/16" DRAIN HOLE w/LIGHT BAFFLE (WHEN NECCESARY) 5" 12ga. STRANDED THHN WIRE, FITTING, & CONDUIT (TO PRIMARY) JUNCTION BOX WIRE NUTELECTRICAL CONDUIT & FITTING JUNCTION BOX POWER SUPPLY PLASTIC BUSHING CRIMP CONNECTOR 18ga. PLTC WIRE TO NEXT LETTER STUD FOR ELECTRICAL GROUNDING SPACER (OPTIONAL) Ø3/8" ALUMINUM RIV-NUT S.S. THREADED ROD w/HEX NUT & LOCK WASHER STEEL ANGLE SILICONE CAULK (APPLIED TO ALL WALL PENETRATIONS) Colors & Materials Chemcast Red Acrylic #2793 Jewelite True Red Trim Cap Pre-Finished Hunter Red Returns Specifications Internally Illuminated Channel Letters (Horizontal) - Chemcast 3/16" Red acrylic faces #2793 - 5" Deep pre-finished Hunter Red returns - 1" Jewelite True Red trim cap *Any channel letter set below 30" to have ¾" trim cap *“Heart” requires 1" trim cap at all times - Red LED Illumination - 120V Power Supplies - Mounted to existing fascia as required 5"92 13/16"42 7/8" 317 9/16" (26'-5 9/16") 169 9/16" 33 3 / 4 " ( V ) Sign Elevation | Front & Side View | IL-33-CL-L (Qty. 1) Scale: 3/16"=1'-0"A 74.43 SQ.FT. B A1 9 Ø1/2" SLEEVE ANCHOR (Ø3/8" BOLT), 2" MINIMUM EMBEDMENT CMU, BRICK Ø3/8" EXPANSION ANCHOR, 2 1/2" MINIMUM EMBEDMENT PRE-CAST CONCRETE, CONCRETE Ø3/8" LAG BOLT, 3" MINIMUM EMBEDMENT WOOD BLOCKING Ø3/8" THREADED ROD EIFS WALL w/ FOAM INSULATION Ø3/8" THREADED ROD w/ALUMINUM OR PVC COMPRESSION SLEEVE WOOD, CONCRETE BLOCK, EIFS WALL SYSTEMS SECTION ANCHOR TYPE WALL TYPE Ø3/8" PIVOTING TOGGLE BOLT 5/8" THICK MIN. PLYWOOD Mounting Options Scale: N.T.S. Typical Section - Face Lit Letter - Flush Mounted & Self Contained Scale: N.T.S.B ALUMINUM RETURN PAN HEAD SCREW TRIM CAP WELD-ON 16 & RESIN BOND OR CHANNEL BOND CHANNEL LOCK OR RIVET ECONOLITE SHEET ALUMINUM BACK / LED MODULE 3/16" THICK PLASTIC FACE Ø5/16" DRAIN HOLE w/LIGHT BAFFLE (WHEN NECCESARY) 5" 12ga. STRANDED THHN WIRE, FITTING, & CONDUIT (TO PRIMARY) JUNCTION BOX WIRE NUTELECTRICAL CONDUIT & FITTING JUNCTION BOX POWER SUPPLY PLASTIC BUSHING CRIMP CONNECTOR 18ga. PLTC WIRE TO NEXT LETTER STUD FOR ELECTRICAL GROUNDING SPACER (OPTIONAL) Ø3/8" ALUMINUM RIV-NUT S.S. THREADED ROD w/ HEX NUT & LOCK WASHER STEEL ANGLE SILICONE CAULK (APPLIED TO ALL WALL PENETRATIONS) Colors & Materials Chemcast Red Acrylic #2793 Jewelite True Red Trim Cap Pre-Finished Hunter Red Returns Specifications Internally Illuminated Channel Letters (Horizontal) - Chemcast 3/16" Red acrylic faces #2793 - 5" Deep pre-finished Hunter Red returns - 1" Jewelite True Red trim cap *Any channel letter set below 30" to have ¾" trim cap *“Heart” requires 1" trim cap at all times - Red LED Illumination - 120V Power Supplies - Mounted to existing fascia as required 5"61 7/8"28 9/16" 211 11/16" (17'-7 11/16") 113 1/16" 22 1 / 2 " ( V ) Sign Elevation | Front & Side View | IL-22-CL-L (Qty. 2) Scale: 1/4"=1'-0"A 33.07 SQ.FT. B A2 10 Ø1/2" SLEEVE ANCHOR (Ø3/8" BOLT), 2" MINIMUM EMBEDMENT CMU, BRICK Ø3/8" EXPANSION ANCHOR, 2 1/2" MINIMUM EMBEDMENT PRE-CAST CONCRETE, CONCRETE Ø3/8" LAG BOLT, 3" MINIMUM EMBEDMENT WOOD BLOCKING Ø3/8" THREADED ROD EIFS WALL w/ FOAM INSULATION Ø3/8" THREADED ROD w/ALUMINUM OR PVC COMPRESSION SLEEVE WOOD, CONCRETE BLOCK, EIFS WALL SYSTEMS SECTION ANCHOR TYPE WALL TYPE Ø3/8" PIVOTING TOGGLE BOLT 5/8" THICK MIN. PLYWOOD Mounting Options Scale: N.T.S. Typical Section - Face Lit Letter - Flush Mounted & Self Contained Scale: N.T.S.B ALUMINUM RETURN PAN HEAD SCREW TRIM CAP WELD-ON 16 & RESIN BOND OR CHANNEL BOND CHANNEL LOCK OR RIVET ECONOLITE SHEET ALUMINUM BACK / LED MODULE 3/16" THICK PLASTIC FACE Ø5/16" DRAIN HOLE w/LIGHT BAFFLE (WHEN NECCESARY) 5" 12ga. STRANDED THHN WIRE, FITTING, & CONDUIT (TO PRIMARY) JUNCTION BOX WIRE NUTELECTRICAL CONDUIT & FITTING JUNCTION BOX POWER SUPPLY PLASTIC BUSHING CRIMP CONNECTOR 18ga. PLTC WIRE TO NEXT LETTER STUD FOR ELECTRICAL GROUNDING SPACER (OPTIONAL) Ø3/8" ALUMINUM RIV-NUT S.S. THREADED ROD w/ HEX NUT & LOCK WASHER STEEL ANGLE SILICONE CAULK (APPLIED TO ALL WALL PENETRATIONS) Colors & Materials Specifications Internally Illuminated Channel Letters B1 1. 2 6 " MAX 36” 6.25" TBD by future tenant. LL approval required for signage & colors. Max 31’ Max SF allowed: 48 11 Ø1/2" SLEEVE ANCHOR (Ø3/8" BOLT), 2" MINIMUM EMBEDMENT CMU, BRICK Ø3/8" EXPANSION ANCHOR, 2 1/2" MINIMUM EMBEDMENT PRE-CAST CONCRETE, CONCRETE Ø3/8" LAG BOLT, 3" MINIMUM EMBEDMENT WOOD BLOCKING Ø3/8" THREADED ROD EIFS WALL w/ FOAM INSULATION Ø3/8" THREADED ROD w/ALUMINUM OR PVC COMPRESSION SLEEVE WOOD, CONCRETE BLOCK, EIFS WALL SYSTEMS SECTION ANCHOR TYPE WALL TYPE Ø3/8" PIVOTING TOGGLE BOLT 5/8" THICK MIN. PLYWOOD Mounting Options Scale: N.T.S. Typical Section - Face Lit Letter - Flush Mounted & Self Contained Scale: N.T.S.B ALUMINUM RETURN PAN HEAD SCREW TRIM CAP WELD-ON 16 & RESIN BOND OR CHANNEL BOND CHANNEL LOCK OR RIVET ECONOLITE SHEET ALUMINUM BACK / LED MODULE 3/16" THICK PLASTIC FACE Ø5/16" DRAIN HOLE w/LIGHT BAFFLE (WHEN NECCESARY) 5" 12ga. STRANDED THHN WIRE, FITTING, & CONDUIT (TO PRIMARY) JUNCTION BOX WIRE NUTELECTRICAL CONDUIT & FITTING JUNCTION BOX POWER SUPPLY PLASTIC BUSHING CRIMP CONNECTOR 18ga. PLTC WIRE TO NEXT LETTER STUD FOR ELECTRICAL GROUNDING SPACER (OPTIONAL) Ø3/8" ALUMINUM RIV-NUT S.S. THREADED ROD w/ HEX NUT & LOCK WASHER STEEL ANGLE SILICONE CAULK (APPLIED TO ALL WALL PENETRATIONS) Colors & Materials Specifications Internally Illuminated Channel Letters B2 1. 2 6 " MAX 24” 6.25" TBD by future tenant. LL approval required for signage & colors. Max 48.5’ Max SF allowed: 97 12 Custom Replacement Faces SIDE A SIDE B 12’ 12’ 2’-6” 2’-6” No structural changes, face changes only. * Sign area of signage not to exceed current existing area