HomeMy WebLinkAboutCSP R51
Parcel #459-185-03
3049 East Coast Hwy, Corona Del Mar, CA
Comprehensive Sign Plan
2
Table of Contents
1. Title Page
2. Table of contents
3. General Sign Requirements
4. Sign Matrix Calculation
5. Overall Site Plan
6. Sign Site Plan
7. Elevations
8. Sign A1
9. Sign A2
10. Sign B1
11. Sign B2
12. Pylon Reface
3
General Sign Construction Requirements
1. All signs and their installation shall comply with all local building and
electrical codes.
2. All electrical signs will be fabricated by a U.L. approved sign company,
according to U.L. specifications and bear U.L. Label.
3. Sign company to be fully licensed with the City and State and shall have full
Workman's Compensation and general liability insurance.
4. All penetrations of building exterior surfaces are to be sealed waterproof in
color and finish to match existing exterior.
5. Internal illumination to be LED and to contain all UL certified components.
6. Painted surfaces to have a satin finish. Only paint containing acrylic
polyurethane products may be used.
7. Logo and letter heights shall be as specified and shall be determined by
measuring the normal capital letter of a type font exclusive of swashes,
ascenders, and descenders. Ascenders & descenders are allowed.
8. All sign fabrication work shall be of excellent quality. All logo images and
type-styles shall be accurately reproduced. Lettering that approximates typestyles
will not be acceptable. The Landlord reserves the right to reject any
fabrication work deemed to be below standard.
9. All lighting must match the exact specification of the approved working
drawings. No exposed conduits will be allowed. Raceways will be allowed for
wall signs on brick facades, in which case the raceway must be painted to match
the facade and is subject to landlord approval. The brace for a canopy installed
sign may also be considered a raceway and must be painted to match the
canopy on which it is installed.
10. Signs must be made of durable rust –inhibiting materials that are
appropriate and complimentary to the building.
11. Color coatings shall exactly match the colors specified on the approved
plans.
12. Joining of materials (e.g., seams) shall be finished in way as to be
unnoticeable. Visible welds shall be continuous and ground smooth. Rivets,
screws, and other fasteners that extend to visible surfaces shall
be flush, filled, and finished so as to be unnoticeable.
13. Finished surfaces of metal shall be free from oil canning and warping. All
sign finishes shall be free from dust, orange peel, drips, and runs and shall have
a uniform surface conforming to the highest standards of the industry.
14. In no case shall any manufacturer’s label be visible from the street from
normal viewing angles.
1. Each Tenant shall submit to Landlord for written approval, three (3)
copies of the detailed shop drawings of this proposed sign, indicating
conformance with the sign criteria herein outlined.
2. The Landlord shall determine and approve the availability and position
of a Tenant name on any ground sign(s).
3. The Tenant shall pay for all signs, related materials and installation fees
(including final inspection costs).
4. The Tenant shall obtain all necessary permits.
5. The Tenant shall be responsible for fulfillment of all requirements of this
sign criteria.
6. It is the responsibility of the Tenant’s sign company to verify all conduit
and transformer locations and service access prior to fabrication.
7. Should a sign be removed, it is the Tenant's responsibility to patch all
holes, paint surface to match the existing color, and restore surface to
original condition.
Landlord / Tenant Requirements
4
5
(E) Pylon Sign
6
Major Tenant Signs: A1, A2
Minor Tenant Signs: B1 - B2
Major Tenant Minor
Tenant
Sign A1 Sign B1
Sign B2
Sign A2
7
Sign A1Sign B1 Sign B2
Sign A2
7
8
Ø1/2" SLEEVE ANCHOR
(Ø3/8" BOLT), 2" MINIMUM
EMBEDMENT
CMU, BRICK
Ø3/8" EXPANSION
ANCHOR, 2 1/2" MINIMUM
EMBEDMENT
PRE-CAST CONCRETE,
CONCRETE
Ø3/8" LAG BOLT,
3" MINIMUM EMBEDMENT
WOOD BLOCKING
Ø3/8" THREADED ROD
EIFS WALL w/
FOAM INSULATION
Ø3/8" THREADED ROD
w/ALUMINUM OR PVC
COMPRESSION SLEEVE
WOOD, CONCRETE
BLOCK, EIFS WALL
SYSTEMS
SECTION
ANCHOR
TYPE
WALL
TYPE
Ø3/8" PIVOTING
TOGGLE BOLT
5/8" THICK MIN.
PLYWOOD
Mounting Options
Scale: N.T.S.
Typical Section - Face Lit Letter - Flush Mounted & Self Contained
Scale: N.T.S.B
ALUMINUM RETURN
PAN HEAD SCREW
TRIM CAP
WELD-ON 16 & RESIN BONDOR CHANNEL BOND
CHANNEL
LOCK OR
RIVET
ECONOLITE SHEET
ALUMINUM BACK /
LED MODULE
3/16" THICK PLASTIC FACE
Ø5/16" DRAIN HOLE w/LIGHT
BAFFLE (WHEN NECCESARY)
5"
12ga. STRANDED THHN
WIRE, FITTING, &
CONDUIT (TO PRIMARY)
JUNCTION BOX
WIRE NUTELECTRICAL CONDUIT & FITTING
JUNCTION BOX
POWER SUPPLY
PLASTIC BUSHING
CRIMP CONNECTOR
18ga. PLTC WIRE
TO NEXT
LETTER
STUD FOR ELECTRICAL GROUNDING
SPACER (OPTIONAL)
Ø3/8" ALUMINUM RIV-NUT
S.S. THREADED ROD w/HEX NUT & LOCK WASHER
STEEL ANGLE
SILICONE CAULK (APPLIED TO
ALL WALL PENETRATIONS)
Colors & Materials
Chemcast Red Acrylic #2793
Jewelite True Red Trim Cap
Pre-Finished Hunter Red Returns
Specifications
Internally Illuminated Channel Letters (Horizontal)
- Chemcast 3/16" Red acrylic faces #2793
- 5" Deep pre-finished Hunter Red returns
- 1" Jewelite True Red trim cap
*Any channel letter set below 30" to have ¾" trim cap
*“Heart” requires 1" trim cap at all times
- Red LED Illumination
- 120V Power Supplies
- Mounted to existing fascia as required
5"92 13/16"42 7/8"
317 9/16" (26'-5 9/16")
169 9/16"
33
3
/
4
"
(
V
)
Sign Elevation | Front & Side View | IL-33-CL-L (Qty. 1)
Scale: 3/16"=1'-0"A 74.43 SQ.FT.
B
A1
9
Ø1/2" SLEEVE ANCHOR
(Ø3/8" BOLT), 2" MINIMUM
EMBEDMENT
CMU, BRICK
Ø3/8" EXPANSION
ANCHOR, 2 1/2" MINIMUM
EMBEDMENT
PRE-CAST CONCRETE,
CONCRETE
Ø3/8" LAG BOLT,
3" MINIMUM EMBEDMENT
WOOD BLOCKING
Ø3/8" THREADED ROD
EIFS WALL w/
FOAM INSULATION
Ø3/8" THREADED ROD
w/ALUMINUM OR PVC
COMPRESSION SLEEVE
WOOD, CONCRETE
BLOCK, EIFS WALL
SYSTEMS
SECTION
ANCHOR
TYPE
WALL
TYPE
Ø3/8" PIVOTING
TOGGLE BOLT
5/8" THICK MIN.
PLYWOOD
Mounting Options
Scale: N.T.S.
Typical Section - Face Lit Letter - Flush Mounted & Self Contained
Scale: N.T.S.B
ALUMINUM RETURN
PAN HEAD SCREW
TRIM CAP
WELD-ON 16 & RESIN BOND
OR CHANNEL BOND
CHANNEL
LOCK OR
RIVET
ECONOLITE SHEET
ALUMINUM BACK /
LED MODULE
3/16" THICK PLASTIC FACE
Ø5/16" DRAIN HOLE w/LIGHT
BAFFLE (WHEN NECCESARY)
5"
12ga. STRANDED THHN
WIRE, FITTING, &
CONDUIT (TO PRIMARY)
JUNCTION BOX
WIRE NUTELECTRICAL CONDUIT & FITTING
JUNCTION BOX
POWER SUPPLY
PLASTIC BUSHING
CRIMP CONNECTOR
18ga. PLTC WIRE
TO NEXT
LETTER
STUD FOR ELECTRICAL GROUNDING
SPACER (OPTIONAL)
Ø3/8" ALUMINUM RIV-NUT
S.S. THREADED ROD w/
HEX NUT & LOCK WASHER
STEEL ANGLE
SILICONE CAULK (APPLIED TO
ALL WALL PENETRATIONS)
Colors & Materials
Chemcast Red Acrylic #2793
Jewelite True Red Trim Cap
Pre-Finished Hunter Red Returns
Specifications
Internally Illuminated Channel Letters (Horizontal)
- Chemcast 3/16" Red acrylic faces #2793
- 5" Deep pre-finished Hunter Red returns
- 1" Jewelite True Red trim cap
*Any channel letter set below 30" to have ¾" trim cap
*“Heart” requires 1" trim cap at all times
- Red LED Illumination
- 120V Power Supplies
- Mounted to existing fascia as required
5"61 7/8"28 9/16"
211 11/16" (17'-7 11/16")
113 1/16"
22
1
/
2
"
(
V
)
Sign Elevation | Front & Side View | IL-22-CL-L (Qty. 2)
Scale: 1/4"=1'-0"A 33.07 SQ.FT.
B
A2
10
Ø1/2" SLEEVE ANCHOR
(Ø3/8" BOLT), 2" MINIMUM
EMBEDMENT
CMU, BRICK
Ø3/8" EXPANSION
ANCHOR, 2 1/2" MINIMUM
EMBEDMENT
PRE-CAST CONCRETE,
CONCRETE
Ø3/8" LAG BOLT,
3" MINIMUM EMBEDMENT
WOOD BLOCKING
Ø3/8" THREADED ROD
EIFS WALL w/
FOAM INSULATION
Ø3/8" THREADED ROD
w/ALUMINUM OR PVC
COMPRESSION SLEEVE
WOOD, CONCRETE
BLOCK, EIFS WALL
SYSTEMS
SECTION
ANCHOR
TYPE
WALL
TYPE
Ø3/8" PIVOTING
TOGGLE BOLT
5/8" THICK MIN.
PLYWOOD
Mounting Options
Scale: N.T.S.
Typical Section - Face Lit Letter - Flush Mounted & Self Contained
Scale: N.T.S.B
ALUMINUM RETURN
PAN HEAD SCREW
TRIM CAP
WELD-ON 16 & RESIN BOND
OR CHANNEL BOND
CHANNEL
LOCK OR
RIVET
ECONOLITE SHEET
ALUMINUM BACK /
LED MODULE
3/16" THICK PLASTIC FACE
Ø5/16" DRAIN HOLE w/LIGHT
BAFFLE (WHEN NECCESARY)
5"
12ga. STRANDED THHN
WIRE, FITTING, &
CONDUIT (TO PRIMARY)
JUNCTION BOX
WIRE NUTELECTRICAL CONDUIT & FITTING
JUNCTION BOX
POWER SUPPLY
PLASTIC BUSHING
CRIMP CONNECTOR
18ga. PLTC WIRE
TO NEXT
LETTER
STUD FOR ELECTRICAL GROUNDING
SPACER (OPTIONAL)
Ø3/8" ALUMINUM RIV-NUT
S.S. THREADED ROD w/
HEX NUT & LOCK WASHER
STEEL ANGLE
SILICONE CAULK (APPLIED TO
ALL WALL PENETRATIONS)
Colors & Materials
Specifications
Internally Illuminated Channel Letters
B1
1.
2
6
"
MAX 36”
6.25"
TBD by future tenant.
LL approval required for signage & colors.
Max 31’
Max SF allowed: 48
11
Ø1/2" SLEEVE ANCHOR
(Ø3/8" BOLT), 2" MINIMUM
EMBEDMENT
CMU, BRICK
Ø3/8" EXPANSION
ANCHOR, 2 1/2" MINIMUM
EMBEDMENT
PRE-CAST CONCRETE,
CONCRETE
Ø3/8" LAG BOLT,
3" MINIMUM EMBEDMENT
WOOD BLOCKING
Ø3/8" THREADED ROD
EIFS WALL w/
FOAM INSULATION
Ø3/8" THREADED ROD
w/ALUMINUM OR PVC
COMPRESSION SLEEVE
WOOD, CONCRETE
BLOCK, EIFS WALL
SYSTEMS
SECTION
ANCHOR
TYPE
WALL
TYPE
Ø3/8" PIVOTING
TOGGLE BOLT
5/8" THICK MIN.
PLYWOOD
Mounting Options
Scale: N.T.S.
Typical Section - Face Lit Letter - Flush Mounted & Self Contained
Scale: N.T.S.B
ALUMINUM RETURN
PAN HEAD SCREW
TRIM CAP
WELD-ON 16 & RESIN BOND
OR CHANNEL BOND
CHANNEL
LOCK OR
RIVET
ECONOLITE SHEET
ALUMINUM BACK /
LED MODULE
3/16" THICK PLASTIC FACE
Ø5/16" DRAIN HOLE w/LIGHT
BAFFLE (WHEN NECCESARY)
5"
12ga. STRANDED THHN
WIRE, FITTING, &
CONDUIT (TO PRIMARY)
JUNCTION BOX
WIRE NUTELECTRICAL CONDUIT & FITTING
JUNCTION BOX
POWER SUPPLY
PLASTIC BUSHING
CRIMP CONNECTOR
18ga. PLTC WIRE
TO NEXT
LETTER
STUD FOR ELECTRICAL GROUNDING
SPACER (OPTIONAL)
Ø3/8" ALUMINUM RIV-NUT
S.S. THREADED ROD w/
HEX NUT & LOCK WASHER
STEEL ANGLE
SILICONE CAULK (APPLIED TO
ALL WALL PENETRATIONS)
Colors & Materials
Specifications
Internally Illuminated Channel Letters
B2
1.
2
6
"
MAX 24”
6.25"
TBD by future tenant.
LL approval required for signage & colors.
Max 48.5’
Max SF allowed: 97
12
Custom Replacement Faces
SIDE A
SIDE B
12’
12’
2’-6”
2’-6”
No structural changes, face changes only.
* Sign area of signage not to exceed current
existing area