Loading...
HomeMy WebLinkAbout05_SKINIC Day Spa Minor Use Permit_PA2024-0239 CITY OF NEWPORT BEACH ZONING ADMINISTRATOR STAFF REPORT July 10, 2025 Agenda Item No. 5 SUBJECT: SKINIC Day Spa (PA2024-0239) ▪ Minor Use Permit SITE LOCATION: 3838 East Coast Highway APPLICANT: Angela Lindsay, SoCal h2H OWNER: The 3838 Corona LLC PLANNER: Oscar Orozco, Associate Planner 949-644-3219, oorozco@newportbeachca.gov LAND USE AND ZONING • General Plan Land Use Plan Category: CC (Corridor Commercial) • Zoning District: CC (Commercial Corridor) PROJECT SUMMARY A request for a minor use permit to allow the operation of a day spa establishment (Personal Services, Restricted), which includes accessory massage services. The applicant proposes to improve a 2,270-square-foot, single-story, commercial building to provide services such as: facials, superficial chemical peels, and accessory massage. The establishment would operate daily until 8:00 p.m., and no late hours (i.e., after 11:00 p.m.) are proposed. RECOMMENDATION 1) Conduct a public hearing; 2) Find this project exempt from the California Environmental Quality Act (CEQA) pursuant to Section 15301 under Class 1 (Existing Facilities) of the CEQA Guidelines, California Code of Regulations, Title 14, Division 6, Chapter 3, because it has no potential to have a significant effect on the environment; and 3) Adopt Draft Zoning Administrator Resolution No. _ approving the Minor Use Permit filed as PA2024-0239 (Attachment No. ZA 1). 1 SKINIC Day Spa (PA2024-0239) Zoning Administrator, July 10, 2025 Page 2 Tmplt: 10/18/21 DISCUSSION • The proposed day spa will be located within an existing commercial building located west of the East Coast Highway and Hazel Drive intersection. The proposed use is a commercial use intended to serve nearby residents of Corona del Mar as well as visitors to the City. • The project site is in the CC (Commercial Corridor) Zoning District and categorized as CC (Corridor Commercial) by the General Plan. This designation is intended to provide a range of neighborhood-serving retail and service uses along street frontages that are located and designed to foster pedestrian activity. While the existing commercial building is adjacent to residential neighborhoods, the building is oriented towards East Coast Highway where the properties fronting East Coast Highway are also in the CC (Commercial Corridor) Zoning District. Therefore, the proposed use is consistent with the Zoning District and General Plan Land Use. • The proposed day spa is classified as a Personal Services, Restricted land use and is allowed subject to the approval of a minor use permit in order to disperse the use from other similar uses in this land use category to minimize potential adverse impacts. The project also includes massage as an accessory component, which also requires a minor use permit. • The day spa is proposed to be located within a recently improved 2,270-square- foot commercial building. The existing building was previously comprised of three tenant spaces; however, a tenant improvement was recently completed to combine the three tenant spaces into one. As a result, and in an effort to improve the site accessibility, a new entrance ramp has been incorporated which has resulted in a reduction in the gross floor area from 2,392 square feet to 2,270 square feet. The proposed day spa use will require a tenant improvement to construct ten individual treatment rooms, an office, employee breakroom, a lobby, and reception area. • As provided in the Applicant’s Project Description (Attachment No. ZA 3), the day spa will offer facials, superficial chemical peels, and accessory massage such as lipomassage. The requested hours of operation are between 10:00 a.m. and 5:00 p.m., Monday through Saturday. Staff recommends a condition of approval limiting the hours of operation to between 10:00 a.m. and 8:00 p.m. daily to allow more operational flexibility in the future. No late hours (past 11:00 p.m.) or alcohol service are proposed as part of this application. • The proposed day spa includes lipomassage, which is considered an accessory use given it comprises less than 10% of the overall service offerings. The project was reviewed by the Police Department and determined not to require an Operator’s Permit for massage under the Municipal Code given that lipomassage 2 SKINIC Day Spa (PA2024-0239) Zoning Administrator, July 10, 2025 Page 3 Tmplt: 10/18/21 is not directly regulated or covered by the California Massage Therapy Council (CAMTC) certification. • The proposed use is surrounded by a range of commercial uses, which includes a hair salon, tailor, florist, and martial arts studio located at the northern property along East Coast Highway across Hazel Drive. The adjacent property to the south along East Coast Highway is vacant. The proposed use provides a different commercial service for nearby residents and the surrounding village of Corona del Mar. • The project site is nonconforming because it does not provide the required number of parking spaces. However, Section 20.38.060(B)(1) of the Newport Beach Municipal Code (NBMC) indicates that a use may be changed to a new use without providing additional parking provided no intensification or enlargement occurs and the new use requires a parking rate of no more than one space per 250-square- feet of gross building area. The proposed day spa is located within a vacant tenant space. Although the three previous suites were merged into one suite, the overall floor area was reduced by approximately 122 square feet. Therefore, no intensification or enlargement is proposed that would trigger additional parking. The primary use of the suite is personal services, which requires a parking rate of one space per 250-square-feet. Therefore, the project would not result in an intensification that requires additional parking pursuant to Section 20.38.060(B)(1). ENVIRONMENTAL REVIEW This project is exempt from the California Environmental Quality Act (CEQA) pursuant to Section 15301 under Class 1 (Existing Facilities) of the CEQA Guidelines, California Code of Regulations, Title 14, Division 6, Chapter 3 because it has no potential to have a significant effect on the environment. This exemption authorizes minor alterations to existing structures involving negligible or no expansion of use. The proposed project includes the operation of a day spa with minor alternations to the tenant space. PUBLIC NOTICE Notice of this application was published in the Daily Pilot, mailed to all owners of property within 300 feet of the boundaries of the site (excluding intervening rights-of-way and waterways), including the applicant, and posted on the subject property at least 10 days before the scheduled hearing, consistent with the provisions of the Municipal Code. Additionally, the item appeared on the agenda for this meeting, which was posted at City Hall and on the City website. 3 SKINIC Day Spa (PA2024-0239) Zoning Administrator, July 10, 2025 Page 4 Tmplt: 10/18/21 APPEAL PERIOD: An appeal or call for review may be filed with the Director of Community Development within 14 days following the date of action. For additional information on filing an appeal, contact the Planning Division at 949-644-3200. Prepared by: ____________________________ Oscar Orozco, Associate Planner LAW/oo Attachments: ZA 1 Draft Resolution ZA 2 Vicinity Map ZA 3 Applicant’s Project Description ZA 4 Project Plans 4 Attachment No. ZA 1 Draft Resolution 5 RESOLUTION NO. ZA2025-### A RESOLUTION OF THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH, CALIFORNIA, APPROVING A MINOR USE PERMIT FOR A DAY SPA (PERSONAL SERVICES, RESTRICTED LAND USE) LOCATED AT 3838 EAST COAST HIGHWAY (PA2024-0239) THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH HEREBY FINDS AS FOLLOWS: SECTION 1. STATEMENT OF FACTS. 1. An application was filed by Angela Lindsay of SoCal h2H on behalf of Marinho Cassiana of The 3838 Corona LLC with respect to property located at 3838 East Coast Highway and legally described as Lots 52 of Block B of Tract No. 673, requesting approval of a minor use permit. 2. A request for a minor use permit to allow the operation of a day spa establishment (Personal Services, Restricted), which includes accessory massage services. The applicant proposes to improve a 2,270-square-foot, single-story, commercial building to provide services such as: facials, superficial chemical peels, and accessory massage. The establishment would operate daily until 8:00 p.m., and no late hours (i.e., after 11:00 p.m.) are proposed. 3. The subject property is designated Corridor Commercial (CC) by the General Plan Land Use Element and is located within the Commercial Corridor (CC) Zoning District. 4. The subject property is not located within the coastal zone. 5. A public hearing was held on July 10, 2025, online via Zoom. A notice of time, place and purpose of the hearing was given in accordance with the Newport Beach Municipal Code (NBMC). Evidence, both written and oral, was presented to, and considered by, the Zoning Administrator at this hearing. SECTION 2. CALIFORNIA ENVIRONMENTAL QUALITY ACT DETERMINATION. 1. This project is exempt from the California Environmental Quality Act (CEQA) pursuant to Section 15301 under Class 1 (Existing Facilities) of the CEQA Guidelines, California Code of Regulations, Title 14, Division 6, Chapter 3 because it has no potential to have a significant effect on the environment. 2. This exemption authorizes minor alterations to existing structures involving negligible or no expansion of use. The proposed project includes the operation of a day spa with minor alternations to the tenant space. 6 Zoning Administrator Resolution No. ZA2025-### Page 2 of 8 SECTION 3. REQUIRED FINDINGS. In accordance with Section 20.52.020 (F) (Conditional Use Permits and Minor Use Permits – Findings and Decision) of the NBMC, the following findings and facts in support of such findings are set forth: Finding: A.The use is consistent with the General Plan and any applicable specific plan. Facts in Support of Finding: 1.The General Plan Land Use category for this property is CC (Corridor Commercial), which is intended to provide a range of neighborhood-serving retail and service uses along street frontages that are located and designed to foster pedestrian activity. 2.The proposed day spa is a personal service use that is consistent with the land uses permitted within this land use designation. The use is intended to serve nearby residents of Corona del Mar as well as visitors to the City. 3.The proposed day spa would be located within an existing commercial building. While the tenant space is adjacent to residential neighborhoods, the building is oriented towards East Coast Highway where the properties fronting East Coast Highway are also in the CC (Commercial Corridor) Zoning District. 4.The subject property is not part of a specific plan area. Finding: B.The use is allowed within the applicable zoning district and complies with all other applicable provisions of this Zoning Code and the Municipal Code. Facts in Support of Finding: 1.The day spa is a permitted use in the CC (Commercial Corridor) Zoning District. The day spa (Personal Services, Restricted) use is permitted with the approval of a minor use permit. A minor use permit is required as the restricted uses may tend to have a blighting and/or deteriorating effect upon surrounding areas and may need to be dispersed from other similar uses to minimize adverse impacts. 2.Section 20.70 (Definitions) of the NBMC defines the personal services, restricted land use as a personal service use that may have a blighting and/or deteriorating effect on surrounding areas and that may need to be dispersed from other similar uses to minimize adverse impacts. The NBMC provides specific examples of personal services, restricted land uses including day spas, healing arts, tanning salons, and body piercing studios. 7 Zoning Administrator Resolution No. ZA2025-### Page 3 of 8 3. Section 20.70 (Definitions) of the NBMC defines a massage services, accessory land use as a massage establishment that is regulated by State law and operated as an accessory use in conjunction with an approved health club, athletic club, gym, or hotel or in conjunction with a medical office or chiropractic office. For the purpose of this definition, an establishment that includes less than 25% of its floor area dedicated toward massage services is considered accessory. The proposed day spa includes lipomassage services which is considered accessory massage given it comprises less than 10% of the service offerings. The project was reviewed by the Police Department and determined not to require a massage permit under the Municipal Code given that lipomassage is not directly regulated or covered by the California Massage Therapy Council (CAMTC) certification. 4. A body piercing studio, another personal services, restricted land use, is located across Hazel Drive approximately 55 feet from the proposed day spa. The surrounding commercial uses are primarily retail, food service, beauty shops, and other commercial uses not classified as personal services, Restricted. Although not a personal services, restricted land use, the nearest massage business is located approximately 650-feet from the property. Therefore, the use is adequately dispersed from similar uses that may create adverse impacts. 5. The project site is nonconforming because it does not provide the required number of parking spaces. However, Section 20.38.060(B)(1) of the NBMC indicates that a use may be changed to a new use without providing additional parking provided no intensification or enlargement occurs and the new use requires a parking rate of no more than one space per 250-square-feet of gross building area. The proposed day spa is located within a vacant tenant space. Although the three previous suites were merged into one suite, the overall floor area was reduced by approximately 122 square feet. Therefore, no intensification or enlargement is proposed that would trigger additional parking. The primary use of the suite is personal services, which requires a parking rate of one space per 250-square-feet. Therefore, the project would not result in an intensification that requires additional parking pursuant to Section 20.38.060(B)(1). Finding: C. The design, location, size, and operating characteristics of the use are compatible with the allowed uses in the vicinity. Facts in Support of Finding: 1. The proposed day spa is located within an existing commercial building that is compatible with the surrounding uses including retail commercial uses. 2. The existing commercial building is oriented towards East Coast Highway and facing away from the adjacent residential neighborhoods. The surrounding properties fronting East Coast Highway are also in the CC (Commercial Corridor) Zoning District to provide a range of commercial uses to serve nearby residential neighborhoods. The nearest residential dwelling is approximately 30 feet from the subject building and separated by the existing parking spaces for the building and an alley. 8 Zoning Administrator Resolution No. ZA2025-### Page 4 of 8 3. Condition of Approval No. 4 limits the hours of operation from 10:00 a.m. to 8:00 p.m., daily. The project does not propose late hours (past 11:00 p.m.) which will minimize any potential disturbance to the residential uses near the property. Finding: D. The site is physically suitable in terms of design, location, shape, size, operating characteristics, and the provision of public and emergency vehicle (e.g., fire and medical) access, and public services and utilities. Facts in Support of Finding: 1. The project site is located west of the East Coast Highway and Hazel Drive intersection. East Coast Highway is a busy commercial corridor with heavy vehicular traffic and pedestrian activity. The onsite parking lot is located at the rear of the property and is conveniently located for patrons and employees. Vehicular access to the parking lot is available via an alley in the rear of the property that is accessible from Hazel Drive. The proposed day spa is not expected to result in increased vehicular and pedestrian traffic. 2. The day spa is proposed to be located within a recently improved 2,270-square-foot commercial building. The existing building was previously comprised of three tenant spaces; however, a tenant improvement was recently completed to combine the three tenant spaces into one. As a result, and in an effort to improve the site accessibility, a new entrance ramp has been incorporated which has resulted in a reduction in the gross floor area from 2,392 square feet to 2,270 square feet. The proposed day spa use will require a tenant improvement to construct ten individual treatment rooms, an office, employee breakroom, a lobby, and reception area. The design, location, shape, size, and operating characteristics of the use are compatible with the existing retail, personal services, and martial arts studio within the surrounding areas. 3. The Fire Prevention Division has reviewed the project to ensure adequate public and emergency vehicle access is provided and does not have any concerns with the proposed use. Finding: E. Operation of the use at the location proposed would not be detrimental to the harmonious and orderly growth of the City, nor endanger, jeopardize, or otherwise constitute a hazard to the public convenience, health, interest, safety, or general welfare of persons residing or working in the neighborhood of the proposed use. Facts in Support of Finding: 1. Fact 3 in support of Finding C is hereby incorporated by reference. 9 Zoning Administrator Resolution No. ZA2025-### Page 5 of 8 2. The proposed day spa has been reviewed by the Building Division, Fire Prevention Division, and Public Works Department and the resolution includes appropriate conditions of approval to ensure that potential conflicts with the surrounding land uses are minimized to the greatest extent possible. The business operator is required to take reasonable steps to discourage and correct objectionable conditions that constitute a nuisance in parking areas, sidewalks, and areas surrounding the subject property and adjacent properties during business hours, if directly related to the patrons of the establishment. 6. The Newport Beach Police Department (NBPD) has reviewed the Project and has no objections. In addition, it was determined by NBMC that the project does not require a massage permit under the Municipal Code given that lipomassage is not directly regulated or covered by the California Massage Therapy Council (CAMTC) certification. SECTION 4. DECISION. NOW, THEREFORE, BE IT RESOLVED: 1. The Zoning Administrator of the City of Newport Beach hereby finds this project is categorically exempt from the California Environmental Quality Act pursuant to Section 15301 under Class 1 (Existing Facilities) of the CEQA Guidelines, California Code of Regulations, Title 14, Division 6, Chapter 3 because it has no potential to have a significant effect on the environment. 2. The Zoning Administrator of the City of Newport Beach hereby approves the Minor Use Permit, subject to the conditions set forth in Exhibit A, which is attached hereto and incorporated by reference. 3. This action shall become final and effective 14 days following the date this Resolution was adopted unless within such time an appeal or call for review is filed with the Community Development Director in accordance with the provisions of Title 20 Planning and Zoning, of the Newport Beach Municipal Code. PASSED, APPROVED, AND ADOPTED THIS 10TH DAY OF JULY, 2025. _______________________________________ Benjamin M. Zdeba, AICP, Zoning Administrator 10 Zoning Administrator Resolution No. ZA2025-### Page 6 of 8 EXHIBIT “A” CONDITIONS OF APPROVAL Planning Division 1. The Project shall be in substantial conformance with the approved site plan and floor plans stamped and dated with the date of this approval (except as modified by applicable conditions of approval). 2. The Project is subject to all applicable City ordinances, policies, and standards unless specifically waived or modified by the conditions of approval. 3. The Applicant shall comply with all federal, state, and local laws. A material violation of any of those laws in connection with the use may cause the revocation of this Minor Use Permit. 4. The hours of operation shall be limited from 10:00 a.m. to 8:00 p.m., daily. 5. The Project’s accessory massage services shall be limited to a maximum of 25% of the overall operation. 6. This Minor Use Permit may be modified or revoked by the Zoning Administrator if determined that the proposed uses or conditions under which it is being operated or maintained are detrimental to the public health, welfare, or materially injurious to the Property or improvements in the vicinity or if the Property is operated or maintained to constitute a public nuisance. 7. Any change in operational characteristics, expansion in the area, or other modification to the approved plans shall require review by the Planning Division. An amendment to this Minor Use Permit or the processing of a new minor use permit may be required. 8. This approval shall expire and become void unless exercised within 24 months from the actual date of review authority approval, except where an extension of time is approved in compliance with the provisions of Section 20.54.060 (Time Limits and Extensions) of the NBMC. 9. Prior to the issuance of a building permit, a copy of this Resolution including conditions of approval Exhibit “A” shall be incorporated into the Building Division and field sets of plans 10. Prior to the issuance of a building permit, the Applicant shall pay any unpaid administrative costs associated with the processing of this application to the Planning Division. 11. Construction activities shall comply with Section 10.28.040 (Construction Activity – Noise Regulations) of the NBMC, which restricts hours of noise-generating construction 11 Zoning Administrator Resolution No. ZA2025-### Page 7 of 8 activities that produce noise to between the hours of 7:00 a.m. and 6:30 p.m. Monday through Friday. Noise-generating construction activities are not allowed on Saturdays, Sundays or Holidays. 12. All noise generated by the proposed use shall comply with the provisions of Chapter 10.26 (Community Noise Control) and other applicable noise control requirements of the NBMC. 13. The business operator shall take reasonable steps to discourage and correct objectionable conditions that constitute a nuisance in parking areas, sidewalks and areas surrounding the Property and adjacent properties during business hours, if directly related to the patrons of the establishment. 14. A Special Events Permit is required for any event or promotional activity outside the normal operational characteristics of the approved use, as conditioned, or that would attract large crowds, involve the sale of alcoholic beverages, include any form of on-site media broadcast, or any other activities as specified in the NBMC to require such permits. 15. All proposed signs shall be in conformance with the provisions of Chapter 20.42 (Sign Standards) of the NBMC. 16. All lighting shall conform to the standards of Section 20.30.070 (Outdoor Lighting) of the NBMC. The Community Development Director may order the dimming of light sources or other remediation upon finding that the site is excessively illuminated. 17. The exterior of the business shall be maintained free of litter and graffiti at all times. The owner or operator shall provide for daily removal of trash, litter debris and graffiti from the premises and on all abutting sidewalks within 20 feet of the premises. 18. The Project shall provide adequate, accessible, and convenient enclosed areas with solid roofs for collecting and loading solid waste, organic materials, and recyclable materials in compliance with Section 20.30.120 (Solid Waste and Recyclable Materials Storage) of the NBMC to the greatest extent possible as determined by the Community Development Department Director. 19. All trash shall be stored within the building or within dumpsters stored in the trash enclosure (if available), except when placed for pick-up by refuse collection agencies. The Applicant shall ensure that the trash dumpsters and/or receptacles are maintained to control odors. This may include the provision of either fully self-contained dumpsters or periodic steam cleaning of the dumpsters, if deemed necessary by the Planning Division. Cleaning and maintenance of trash dumpsters shall be done in compliance with the provisions of Title 14, including all future amendments (including Water Quality related requirements). 20. Trash receptacles for patrons shall be conveniently located inside of the establishment. 12 Zoning Administrator Resolution No. ZA2025-### Page 8 of 8 21. Storage outside of the building in the front or at the rear of the Property shall be prohibited, with the exception of the trash container on pick-up days. 22. Should the Property be sold or otherwise come under different ownership, any future owners or assignees shall be notified of the conditions of this approval by either the current business owner, property owner or leasing agent. 23. To the fullest extent permitted by law, applicant shall indemnify, defend and hold harmless the City, its City Council, its boards and commissions, officials, officers, employees, and agents from and against any and all claims, demands, obligations, damages, actions, causes of action, suits, losses, judgments, fines, penalties, liabilities, costs and expenses (including without limitation, attorney’s fees, disbursements and court costs) of every kind and nature whatsoever which may arise from or in any manner relate (directly or indirectly) to City’s approval of the SKINIC Day Spa including, but not limited to, the Minor Use Permit filed as PA2024-0239. This indemnification shall include, but not be limited to, damages awarded against the City, if any, costs of suit, attorneys' fees, and other expenses incurred in connection with such claim, action, causes of action, suit or proceeding whether incurred by applicant, City, and/or the parties initiating or bringing such proceeding. The applicant shall indemnify the City for all of City's costs, attorneys' fees, and damages which the City incurs in enforcing the indemnification provisions set forth in this condition. The applicant shall pay to the City upon demand any amount owed to the City pursuant to the indemnification requirements prescribed in this condition. Building Division 24. The Applicant shall obtain all applicable permits from the City’s Building Division and Fire Department. The construction plans must comply with the most recent, City-adopted version of the California Building Code. 25. The Project shall include an accessible path from the parking area and the public right of way to the tenant space. Fire Department 26. This project will require a fire sprinkler system in accordance with 2022 CFC 903 and 2022 NFPA13. Public Works Department 27. The Project parking layout shall comply with City Standard 105. 28. The Applicant shall install a new sewer clean out on the existing sewer lateral per City Standard 406. 13 Attachment No. ZA 2 Vicinity Map 14 VICINITY MAP Minor Use Permit (PA2024-0239) 3838 East Coast Highway Subject Property 15 Attachment No. ZA 3 Applicant’s Project Description Letter 16 Angela VanDeVelde Salley, LEED AP 1191 El Camino Drive Costa Mesa, CA 92626 949.872.1179 Angela@SoCalh2H.com 20th of December, 2024 REV. 2 - 12th of March, 2025 Minor Use Permit for SKINIC 3838 E. Coast Highway, Corona del Mar, CA 92625 Application No. PA2024-0239 Project Description Dear Sir or Madame I hope this message finds you well. My name is Angela Salley, and I am the Architect for the commercial space at 3838 E. Coast Highway, Corona del Mar, CA 92625 , on behalf of SKINIC, LLC . This letter serves as our project description for planning approval of a minor use permit. SKINIC, LLC is 100% owned by Cassie Marinho , founder and president. Renan Maurice serves as CEO, but holds no shares in the company. Their contact details are as follows: SKINIC, LLC Cassiana Marinho, Founder and President Email: cassie@skinic.co Phone: (310)654-4701 Business Address: 8432 Santa Monica Blvd, West Hollywood, CA 90069 Renan Maurice, CEO Email: renan@skinic.co Phone: (310)654-4700 17 My Architectural office is located at 1191 El Camino Drive, Costa Mesa, CA 92626 and my contact details are below: Angela VanDeVelde Salley : owner,Architect & designer Phone: (949)872-1179 Email: Angela@SoCalh2H.com CAB license number: C-32685 a.) 20.52.020 F - Findings required for a Minor Use Permit. 1.) The use is consistent with the General Plan and any applicable specific plan. The general plan designates the site as part of the Commercial Corridor Zone in Corona del Mar (CDM). SKINIC, a medspa, is a commercial use. 2.) The use is allowed within the applicable zoning district and complies with all other applicable provisions of this Zoning Code and the Municipal Code. CC (Commercial Corridor) Zoning District. The CC Zoning District is intended to provide for areas appropriate for a range of neighborhood-serving retail and service uses along street frontages that are located and designed to foster pedestrian activity. SKINIC is a personal services business as described below and is a permitted use in the commercial corridor. 3.) The design, location, size and operating characteristics of the use are compatible with the allowed uses in the vicinity The new design of SKINIC is more in keeping with the high-end retail offerings along the commercial corridor in CDM. It is an aesthetic upgrade to the existing building that sits in its location, with no added area. We are actually proposing to reduce the area of the existing building to add an accessible entrance ramp. The proposed size is consistent with its predecessor, despite being slightly smaller. However, it is actually a story or 2 less than its neighbors, and half-buried in a hill. In the future, we will apply for a variance to increase the F.A.R. of SKINIC, allowing its height to be even more compatible with its surroundings. SKINIC will operate during standard business hours (10 AM - 5PM) on weekdays and on Saturdays. Business Operation and Impacts ● Operating Hours: Monday through Saturday, 10:00 AM to 5:00 PM ● Staff: The business will employ three (3) estheticians, one (1) office manager, and one (1) receptionist with two (2) shifts per day, resulting in the creation of 10 new jobs in the Newport Beach area. ● Low-Impact Business: The business model is designed to be minimally invasive to the surrounding area. SKINIC will generate minimal traffic, require little parking, and will not produce noise, dust or other disruptions. The overall aesthetic of the business will enhance the appeal of Corona del Mar with its elegant, high-end look. 18 Community and Economic Benefits By providing high-quality cosmetic services in a beautifully designed commercial space, SKINIC will contribute to the beautification of the Corona del Mar neighborhood. Furthermore, the creation of new jobs and increased tax revenue will support the economic development of Newport Beach, while enhancing the area's reputation as a desirable, high-end destination. We believe that SKINIC will attract visitors and bolster the vibrant community atmosphere. 4.) The site is physically suitable in terms of design, location, shape, size, operating characteristics and the provision of public and emergency vehicle (e.g. fire and medical) access and public services and utilities The site currently houses a facility of similar size, shape and operating characteristics. There will be no change to the provision of access for emergency vehicles. There will be an aesthetic upgrade to the design. 5.) Operation of the use at the location proposed will not be detrimental to the harmonious and orderly growth of the city, nor endanger, jeopardize or otherwise constitute a hazard to the public convenience, health, interest, safety or general welfare of persons residing or working in the neighborhood of the proposed use. Operation of SKINIC’s current location in West Hollywood shows that they have a low parking demand and negligible traffic impacts, meaning that it will not impact the public convenience or welfare of persons residing in the area. Though “lipomassage” is listed as an available service on the company website, it should be noted that this is just a name used for lymphatic drainage which is strictly paired with body contouring treatments. It is a water retention treatment that is not in any way relaxing. These treatments are performed on women, by women. They do not come with the traditional stigma of massage parlor establishments. Lipomassage makes up less than 10% of SKINIC’s business. b.) Full description of work occurring on site 1.) Land Use Changes The existing structure at 3838 E. Coast Highway is a 2,392 s.f. Type III single story commercial building that had 3 tenants. Unit ‘A’ was occupied by a dog grooming facility and was 734 s.f. of net leasable area. Unit ‘B’ was occupied by a similar MedSpa use and was 738 s.f. of net leasable area. Unit ‘C’ was occupied by a dry cleaners and was 724 s.f. of net leasable area. The facility was already under-parked with only 4 existing parking spaces and no accessible parking stalls. We have been approved by the planning department to proceed with Non-conforming parking per NBMC 20.38.060. 19 2.) Physical Alterations to the Building After being purchased by SKINIC, the team obtained a demolition permit to combine the 3 tenant spaces into one single-use facility, a MedSpa. In the meantime, the team has been working to revise the street frontage to allow for an accessible entrance ramp, which resulted in the reduction of the gross building footprint from 2,392 s.f. To 2,270 s.f. During the demolition of the interior walls, it was noted that many of the structural elements were rotting and were not suitable for reuse. Therefore, it is proposed that the new facility will make use of the existing retaining walls to the north and north-east, and the demising wall to the west. However, the roof and floor will need to be demolished and rebuilt as part of the building transformation. The new aesthetic of the building will include a corner signage feature that leads to an internal garden of steps and a visible entrance ramp. The large glazing of the original facility will be replaced with a similarly large glazing wall that is straight along the back side of the ramp. The canvas canopies will be replaced with a modern metal awning that has a tongue and groove wood or wood-look ceiling beneath it. The building will again have a flat roof, but all rooftop equipment will be relocated to concealed locations TBD. c.) Further elaboration of services offered on site. Business Overview: SKINIC is a body aesthetics center operated by licensed estheticians. Our services are entirely cosmetic in nature, focusing on skin care treatments such as facials, superficial chemical peels, and body treatments. It is crucial to emphasize that SKINIC is not a medical facility, nor does it provide massage services beyond lipomassage. All services are non-invasive, designed to enhance skin health and beauty without any medical or therapeutic interventions. Below is a breakdown of the scope of services: DO’s : ● Promote skin health, wellness and vitality ● Improve skin appearance, including tone, texture and color ● Combat the effects of aging and sun exposure ● Body Contouring DON’T’s : ● Diagnose skin conditions ● Prescribe medications ● Provide medical treatments such as injectables (e.g. Botox) or deep chemical peels ● Dermal fillers ● Laser Hair Removal ● IV hydration (no injectables of any kind) ● Rejuvenation SKINIC does employ a supervising doctor. However, the doctor is not present on site and does not supervise the treatments. 20 d.) Further elaboration on “Lipomassage.” Though “lipomassage” is listed as an available service on the company website, it should be noted that this is just a name used for lymphatic drainage which is strictly paired with body contouring treatments. It is a water retention treatment that is not in any way relaxing. These treatments are performed on women, by women. They do not come with the traditional stigma of massage parlor establishments. Lipomassage makes up less than 10% of SKINIC’s business. Conclusion We respectfully request your approval of the minor use permit for this project, allowing us to proceed with the next steps in the development process. SKINIC will not only be a valuable addition to the Corona del Mar community but will also bring both aesthetic and economic benefits to the broader Newport Beach area. Thank you for your time and consideration. We look forward to your favorable review. 21 Tmplt: 10/18/21 Attachment No. ZA 4 Project Plans 22 SHEET TITLE PROJECT TITLE SHEET NO. SCALE DATE ARCHITECT ANGELA SALLEYGENERAL NOTES 1.THE CONTRACT DOCUMENTS OF WHICH THESE DRAWINGS AND THE SPECIFICATIONS ARE A PART, ARELEGAL INSTRUMENTS OF SERVICE FOR THE USE OF THE OWNER AND THE AUTHORIZED REPRESENTATIVESON THE DESIGNATED PROPERTY ONLY. ANY OTHER USE WITHOUT THE EXPRESSED WRITTEN PERMISSIONOF THE ARCHITECT IS PROHIBITED. 2. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY OF ANY OMISSIONS OR DISCREPANCIESBETWEEN THE ARCHITECTURAL DRAWINGS, CONSULTING PROFESSIONAL'S DRAWINGS, SPECIFICATIONSOR EXISTING CONDITIONS. THIS NOTIFICATION SHALL BE MADE TO THE ARCHITECT IN WRITING PRIOR TOINSTALLATION OF THE WORK. 3. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND EXISTING CONDITIONS PRIOR TOCOMMENCING WORK AND REPORT ANY DISCREPANCIES IN WRITING TO THE ARCHITECT. ANY WORKINSTALLED IN CONFLICT WITH THE ARCHITECTURAL DRAWINGS SHALL BE CORRECTED BY THECONTRACTOR ENTIRELY AT HIS EXPENSE. 4. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY IF INFORMATION IS NOT SHOWN OR ISUNCLEAR. 5. THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL STIFFENERS, BRACING, BLOCKING, BACKING,HANGERS, BACK-UP PLATES, AND SUPPORTING BRACKETS REQUIRED FOR CASEWORK, BATHROOMACCESSORIES, FIXTURES, MISCELLANEOUS EQUIPMENT AND FURNISHINGS. 6. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE. DO NOT SCALE DRAWINGS. THECONTRACTOR SHALL BE RESPONSIBLE FOR THE ACCURATE PLACEMENT OF THE BUILDING ON THE SITE. 7. ALL EXTERIOR WALL DIMENSIONS SHOWN ON THESE DRAWINGS ARE TO THE FACE OF THE STUD WALLS,OR TO THE FACE OF CONCRETE OR MASONRY UNLESS OTHERWISE NOTED. 8. ALL INTERIOR WALL DIMENSIONS SHOWN ON THESE DRAWINGS ARE TO THE FACE OF GYPSUM BOARDAT STUD WALLS, OR TO THE FACE OF CONCRETE OR MASONRY UNLESS OTHERWISE NOTED. 9. ALL CEILING HEIGHT DIMENSIONS SHOWN ON THESE DRAWINGS ARE TO THE FINISHED CEILING SURFACEUNLESS OTHERWISE NOTED. 10. ALL DOOR SIZES SHOWN THE DOOR SCHEDULE ARE OPENING SIZES. ALLOWANCES FOR THRESHOLDS,ETC. SHALL BE DEDUCTED. 11. THE CONTRACTOR SHALL PROVIDE THERMAL INSULATION IN ALL EXTERIOR WALLS, RAISED FLOOR ANDROOF CAVITIES WITH A MINIMUM RATING AS SHOWN IN THE DRAWINGS AND TITLE 24 COMPLIANCEFORMS. THE THERMAL INSULATION SHALL FORM A CONTINUOUS BARRIER. 12. OPEN EXTERIOR JOINTS AROUND THE WINDOW AND DOOR FRAMES, BETWEEN WALLS ANDFOUNDATIONS, BETWEEN WALLS AND ROOFS, AND AT PENETRATIONS OF UTILITIES THROUGH THEENVELOPE, SHALL BE SEALED, CAULKED, OR WEATHER-STRIPPED TO LIMIT AIR LEAKAGE. 13. THE CONTRACTOR SHALL INSTALL CASING BEADS WHEREVER WALL BOARD OR PLASTER ABUTS ADISSIMILAR FINISH MATERIAL AND PROVIDE SEALANT. INSTALL METAL CORNER BEADS AT ALL EXPOSEDWALLBOARD EDGES. 14. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS AND APPROVALS FOR ALL WORK. 15. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SCHEDULING AND COORDINATION OF THE WORKFOR ALL UTILITIES AND SERVICES. 16. ALL WORK SHALL COMPLY WITH THE 2022 CBC AND ALL LOCAL DEPT. OF BUILDING & SAFETY CODESAND REGULATIONS. 17. ALL SUB CONTRACTORS WORKMANSHIP SHALL BE OF QUALITY TO PASS INSPECTIONS BY LOCALAUTHORITIES OR BY BUILDER. 18. SUB CONTRACTORS SHALL BE LIABLE FOR ANY DAMAGES TO OWNER'S PROPERTY AS A RESULT OFNEGLIGENCE. 19. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES WHETHERSHOWN HEREIN OR NOT, AND TO PROTECT THEM FROM DAMAGE. 20. ALL ELECTRICAL WORK SHALL COMPLY WITH ALL GOVERNING CODES, RULES, AND REGULATIONS OFGOVERNING AGENCIES AND SHALL COMPLY WITH REQUIREMENTS OF THE SERVICING POWER ANDTELEPHONE COMPANIES. 21. LUMBER: ALL VERTICAL AND HORIZONTAL LUMBER SHALL BE GRADE MARKED DOUGLAS FIRCONSTRUCTION GRADE #1 FOR ALL 4XD, 6XD, AND LARGER, AND GRADE #2 FOR ALL 2XD ANDSMALLER. 22. PROVIDE APPROVED BLOCKING AT ALL UNSUPPORTED EDGES OF PLYWOOD ROOF SHEATHING. 23. ALL NAILING SHALL COMPLY WITH 213 CBC. 24. ROOFING NAILS AND ALL EXPOSED NAILS SHALL BE GALVANIZED. 25. PROVIDE WALL CORNER BRACING AS REQUIRED BY CODE. 26. THE CENTER FOR VENT PIPES, HEATER PIPES, SHALL BE NOT LESS THAN 12" FROM THE CENTER OF ANYVALLEY. 27. ALL SHEET METAL TO BE 26 GA. GALVANIZED UNLESS OTHERWISE NOTED. USE 28 GA. GALVANIZEDVALLEY FLASHING (PER CBC). 28. ALL ELECTRICAL WIRING TO BE COPPER. ALUMINUM WIRING SHALL NOT BE USED. 29. ALL DUPLEX OUTLETS IN BATHROOMS SHALL BE GROUND FAULT INTERRUPTER CIRCUIT TYPE (GFCI). 30. N.T.S. INDICATES NOT TO SCALE. 31. EXISTING CONDITION DIMENSIONS TAKE PRECEDENT TO DRAWING DIMENSIONS. DO NOT SCALEWORKING DRAWINGS. 32. FOR MORE SPECIFIC NOTES REGARDING FOUNDATIONS, FRAMING OR FLOOR PLANS - SEE PLANS. 33. CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITECONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALLPERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITEDTO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THEOWNER AND THE DESIGNER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, INCONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT. 34. CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT 1-800-422-4133, 48 HOURS INADVANCE OF COMMENCEMENT OF CONSTRUCTION, FOR EXISTING UTILITIES. 35. CONTRACTOR TO PROVIDE 3 COPIES OF THE BMP WHICH INCLUDES ALL STRUCTURAL DEVICES AT TIMEOF PERMIT ISSUANCE. A REDUCED SCALE PLAN MAY BE PROVIDED. TENANT IMPROVEMENTS 3838 EAST COAST HIGHWAY CORONA DEL MAR, CALIFORNIA TEL:FAX:CONTACT:E-MAIL: STRUCTURAL SQUARE ONE STRUCTURAL13191 DEAN STTUSTIN, CA 92780714.423.6332 VINH DAOVINH@SQ1STRUCTURAL.COM 2022 CALIFORNIA RESIDENTIAL CODE2022 CALIFORNIA BUILDING CODE2022 CALIFORNIA ELECTRICAL CODE2022 CALIFORNIA PLUMBING CODE2022 CALIFORNIA MECHANICAL CODE2022 CALIFORNIA ENERGY CODE2022 CGBC (CALGREEN)2022 CALIFORNIA FIRE CODENFPACHAPTER 11B, 2022 CBC / AADAGANSI A117.1-2003 TEL:FAX:CONTACT:E-MAIL: MECHANICALMARS ENGINEERING GROUP INC.22715 VICTORY BLVDWEST HILLS, CA 91307818.593.8999 MAJID AMIRIMAJID@MARSENGINEERING.NET PROJECT TEAM NO WORK ON WEEKENDS TEL:FAX:CONTACT:E-MAIL: ARCHITECTANGELA SALLEY, ARCHITECT1191 EL CAMINO DRCOSTA MESA, CA 92626(949)872-1179 ANGELA SALLEYANGELA@SOCALH2H.COM GOVERNING CODES LEGAL DESCRIPTIONTRACT #: 673 LOT: 52 BLOCK: BA.P.N. #: 459-123-01PROJECT IMAGES TEL:FAX:CONTACT:E-MAIL: OWNER RENAN & CASSIE MAURICESKINIC.CO 310.654.4700 RENAN MAURICERENAN@SKINIC.CO A-00 PROJECT DATA & INDEX TEL:FAX:CONTACT:E-MAIL: CONTRACTORA BLU CONCEPT1696 NEWPORT BLVD, SUITE BCOSTA MESA, CA 92627619.621.0314 FERNANDO TRUJILLOFERNANDO@ABLUCONCEPT.COM VICINITY / SETBACK MAP REV.ARCHITECTURAL OCCUPANCY: B SCOPE OF WORK: TENANT IMPROVEMENTS TYPE OF CONSTRUCTION: VB, SPRINKLERED LOT SIZE: 3,436 S.F. A-00 PROJECT DATA & INDEX REV.MECHANICAL REV.STRUCTURAL SCOPE OF WORK SHEET INDEX A-10 FLOOR PLANS CREATE A NEW TENANT SPACE FOR SKINIC, AN AESTHETICS CLINIC.DEMO ALL EXISTING NON-RETAINING WALLS, STRUCTURE AND ROOF.DOCUMENTATION OF UNREASONABLE HARDSHIP TO CREATE ACCESSIBLE PARKING AND ACCESSDUE TO THE SLOPE OF THE SITE. TO THE MAXIMUM EXTENT FEASIBLE, ACCESSIBILITYIMPROVEMENTS WILL BE MADE TO THE BUILDING ENTRANCE BY CREATING AN ACCESSIBLE RAMPFROM THE PUBLIC SIDEWALK.NEW FRONT ENTRY FEATURE, WALL, RAMP AND SHADE CANOPY, NEW ROOF.RELOCATE & SCREEN HVAC EQUIPMENT. ZONE: CC - COMMERCIAL CORRIDOR PROPOSED GROSS BUILDING AREA: 2,270 S.F. MAX. F.A.R.: 3,436 S.F. x .75 = 2,577 S.F. A-10 FLOOR PLANSA-11 PROPOSED FLOOR PLANSA-12 REFLECTED CEILING PLANSA-20 EXISTING ELEVATIONS A-30 PROPOSED SECTIONSA-40 INTERIOR ELEVATIONS A-45 INTERIOR FINISH SCHEDULE EXISTING GROSS BUILDING AREA: 2,392 S.F. 2,270 S.F. < 2,577 S.F. (COMPLIES) A-09 SITE PLANS A-21 PROPOSED ELEVATIONS A-50 ARCHITECTURAL DETAILSA-51 ARCHITECTURAL DETAILSA-52 ARCHITECTURAL DETAILS M-1.0 MECHANICAL NOTES & SCHEDULESM-1.1 MECHANICAL NOTES & SCHEDULESM-2.0 MECHANICAL CEILING PLANM-2.1 MECHANICAL ROOF PLANM-3.0 MECHANICAL DETAILSM-4.0 MECHANICAL ENERGY FORMSM-4.1 MECHANICAL ENERGY FORMSE1.0 NOTES, SYMBOLS AND ELECTRICAL SPECIFICATIONSE2.0 EXISTING SINGLE LINE DIAGRAM, AND PANELS SCHEDULEE3.0 FLOOR PLAN - LIGHTING AND SPECIFIC NOTESE3.1 FLOOR PLAN - POWER AND SPECIFIC NOTESE3.2 HVAC ROOF PLAN AND SPECIFIC NOTESE4.0 INDOOR LIGHTING COMPLIANCE TITLE 24 FORMSE4.1 OUTDOOR LIGHTING COMPLIANCE TITLE 24 FORMSP-1.0 PLUMBING NOTES, LEGENDP-2.0 PLUMBING WASTE AND VENT PLANP-3.0 PLUMBING WATER SUPPLYP-4.0 PLUMBING RISER DIAGRAMP-5.0 PLUMBING DETAILSP-6.0 PLUMBING ENERGY FORMS S-1 FOUNDATION PLANS-1 ROOF FRAMING PLANSD-0 GENERAL NOTESSD-1 DETAILSSD-2 DETAILSSD-3 DETAILS A-01 CALGREEN MINIMUM REQUIREMENTS A-44 DOOR & WINDOW SCHEDULE BUSINESS OVERVIEW SKINIC is a body aesthetics center operatedby licensed estheticians. Our services areentirely cosmetic in nature, focusing on skincare treatments such as facials, superficialchemical peels, and body treatments. It iscrucial to emphasize that SKINIC is not amedical facility, nor does it provide massageservices beyond lipomassage. All services arenon-invasive, designed to enhance skin healthand beauty without any medical or therapeuticinterventions. Below is a breakdown of thescope of services: DO’s:Promote skin health, wellness and vitalityImprove skin appearance, including tone,texture and colorCombat the effects of aging and sun exposureBody Contouring DON’T’s:Diagnose skin conditionsPrescribe medicationsProvide medical treatments such as injectables(e.g. Botox) or deep chemical peelsDermal fillersLaser Hair RemovalIV hydration (no injectables of any kind)RejuvenationSKINIC does employ a supervising doctor.However, the doctor is not present on siteand does not supervise the treatments. Further elaboration on “Lipomassage.”Though “lipomassage” is listed as an availableservice on the company website, it should benoted that this is just a name used forlymphatic drainage which is strictly paired withbody contouring treatments. It is a waterretention treatment that is not in any wayrelaxing.These treatments are performed on women,by women. They do not come with thetraditional stigma of massage parlorestablishments.Lipomassage makes up less than 10% ofSKINIC’s business. Individuals will be capable of self-preservationat all times. DEFERRED SUBMITTALS FIRE PROTECTION FIRE HAZARD SEVERITY ZONE 23 SHEET TITLE PROJECT TITLE SHEET NO. SCALE DATE ARCHITECT ANGELA SALLEY A-01 CALGREEN MINIMUM REQUIREMENTS 24 4 4 YD 4 4 YD SHEET TITLE PROJECT TITLE SHEET NO. SCALE DATE ARCHITECT ANGELA SALLEY A-09 SITE PLANS (N)OVERFLOW ROOFDRAIN TO DRAINTO SCUPPER ELEVATE ULTRAPLYTPO ROOFINGMEMBRANE ESR-2831 SITE PLAN NOTES: PARKING REQUIREMENTS 20.38.060 Nonconforming Parking PROPOSED USE: ELECTRICAL EQUIP., STACKED & MOUNTEDON (E) WALL BEHIND(N) LOCKED GATE EXISTING / DEMO SITE PLAN PROPOSED SITE PLAN PUBLIC WORKS: 25 A-10 SHEET TITLE PROJECT TITLE SHEET NO. SCALE DATE ARCHITECT ANGELA SALLEY EXISTING / DEMO PLAN DEMO PLAN 2288 S.F. EXISTING SHELL SPACE (E) HOT WATER HEATER TO BEDEMOLISHED UNISEXBATHROOM (E) STRUCTURALWALL TO BEDEMOLISHED (E) STRUCTURALBEAMS & ROOF TO BEDEMOLISHED (E) SKYLIGHTS TOBE DEMOLISHED ENTRY PATIO GENERAL DEMOLITION NOTES: DEMOLITION REQUIREMENTS (E) CMU STRUCTURALRETAINING WALLSTO REMAIN (E) CMU STRUCTURALDEMISING WALL TOREMAIN (E) WINDOWS TOBE DEMOLISHED SITE TO BE FENCED AT A HEIGHT BETWEEN 72AND 84 INCHES USING A CHAINLINK OVERLAID ON THE EXTERIOR WITH AN OPAQUE VINYLFENCE. A TEMPORARY PROJECTINFORMATION SIGN SHALL BE AFFIXED TO THE FENCE IN ACCORDANCE WITH A/A-10 N.T.S. TEMPORARY PROJECT INFORMATION SIGN SPECIFICATIONSA HATCHED AREAREPRESENTS (E) SLABTO BE DEMOLISHED 26 BREAK ROOM ADA UNISEX OFFICE /FUTURE ELEVATOR ROOM 10 ROOM 9 ROOM 8ROOM 3 ROOM 2 ROOM 1 A.D.A. ROOM 4 ROOM 5 ROOM 7 CORRIDOR WAITING ROOM RECEPTION A A-40 D A-40C B F A-40 GE H A-40 I A-40J CLIENT KITCHEN ADA UNISEX UTILITIES /SUPPLIES ROOM 6 6 5 B A 1 1 2 2 2 3 2 2 2 2 4 2 2 2 A A 2 2 C C G A-52 A-11 SHEET TITLE PROJECT TITLE SHEET NO. SCALE DATE ARCHITECT ANGELA SALLEY PROPOSED PLAN PROPOSED PLAN BUILDING CODE DATA BUILDING USE: TENANT SPACE (CBC SEC 303.1)OCCUPANCY (CBC, SEC. 303.1): TYPE OF CONSTRUCTION (CBC, SEC. 602.5): BUSINESS - GROUP B III (SPRINKLERED) OCCUPANT LOAD & EXITING: GROSS BUILDING AREA:NET TENANT AREA:OCCUPANT LOAD (100 SF/ OCC):NUMBER OF EXITS REQUIRED:EXITS PROVIDED:EXIT WIDTH REQUIRED (21X .2):EXIT WIDTH PROVIDED: TABLE A OCCUPANT LOAD FACTOR: B SPACES (1:100 SF)2127 / 150 = 122 OCCUPANTS PLUMBING FIXTURE COUNTS WATER CLOSETS:1. MEN (1:1-50 OCC.) 2. WOMEN (1:1-15 OCC.) LAVATORIES1. MEN (1:1-75 OCC.) 2. WOMEN (1:1-50 OCC.) MEN = 22 / 2 = 111 M. W.C. REQ'D2 UNISEX PROVIDED (COMPLIES) WOMEN = 22 / 2 = 111 W. W.C. REQ'D2 UNISEX PROVIDED (COMPLIES) MEN = 22/ 2 = 111 M. LAV. REQ'D2 UNISEX PROVIDED (COMPLIES) WOMEN = 22 / 2 = 111 W. LAVS REQ'D2 UNISEX PROVIDED (COMPLIES) 2,217 SF2,127 SF22 OCCUPANTS124.2" (0.35')72" (6'-0") 27 A-12 SHEET TITLE PROJECT TITLE SHEET NO. SCALE DATE ARCHITECT ANGELA SALLEY PROPOSED REFLECTED CEILING PLAN REFLECTED CEILING PLAN 28 A-20 SHEET TITLE PROJECT TITLE SHEET NO. SCALE DATE ARCHITECT ANGELA SALLEY EXISTING ELEVATIONS FRONT ELEVATION SIDE ELEVATION A B C D E F G H I J K L M N O P Q R S A D C E E F H B H I ABGCI D 29 A-21 SHEET TITLE PROJECT TITLE SHEET NO. SCALE DATE ARCHITECT ANGELA SALLEY PROPOSED ELEVATIONS FRONT ELEVATION SIDE ELEVATION A B C D E F G H I J K L M N O P Q R S A H D G E M F D L C B I J K H N A DIKDO 30 A-30 SHEET TITLE PROJECT TITLE SHEET NO. SCALE DATE ARCHITECT ANGELA SALLEY PROPOSED SECTIONS SECTION A-A SECTION B-B 31 B A 1 1 A A A-31 SHEET TITLE PROJECT TITLE SHEET NO. SCALE DATE ARCHITECT ANGELA SALLEY ENLARGED STAIR & RAMP DETAILS ENLARGED STAIR SECTION A B C D E F G H I J K L M N O P Q R S A E F G H H B C E D A ENLARGED RAMP SECTION ENLARGED ENTRY STAIR & RAMP PLAN 32 A-32 SHEET TITLE PROJECT TITLE SHEET NO. SCALE DATE ARCHITECT ANGELA SALLEY WALL SECTIONS WALL SECTION 1WALL SECTION 2WALL SECTION 3 33 1'-6"1'-6" 9" WC1 WC2 PF9 PF8 34" M A X . 40 " M A X . 27" M I N . PF8 48 " M A X . 33" - 3 6 " 38 " M I N . 9'- 0 " 33" - 3 6 " 17" MIN.24" 9" 2'-0"1'-0" 10" WC2 PF7 PF1 TR2 9'- 0 " WC2 TR2 EQ.EQ.EQ. 9'- 0 " 10 " 8" 8" 8" 6'- 0 " 3'- 6 " 8'-0 " 1'-6"7'-5 1/2"1'-6" 5 1/ 2 " 8'-5 1/4" TR1 WC3 WC3 WC3 WC2 S1 TR1 3'-0" 3'-11" 2'- 8 " 10 " 2'-8" 9'- 0 " EQ EQ EQ 3'-0 " 1'- 6 " 8'- 0 " 3'-6 " 2'-6"3'-5" WC2 A1 9'- 0 " WC3WC2 9'-10" 2'-4" 4"6'-6" 2'-4" H1 WC2 WC3 TR1 18"MIN.1'-8" 18"MIN.20" 27" M I N . 40 " M A X . 34 " M A X . 9" 2'-4"6" PF3 PF2 WC2 42" MIN. 24" MIN. 33" - 3 6 " TR2 WC2 8'- 0 " 2'-8" 3'- 0 " 2'- 4 " 3'- 8 " 2'- 9 " 7'-9" 2'-3"2'-6"2'-8" EQ EQ EQ EQ 3'-0" A1A2 PF6WC2 S1 PF4 2'-7 3/4"1'-0" 3'- 0 " 1'- 6 " 9'- 0 " 3'- 6 1/ 4 " A2 TR2 WC2 A3 A-40 SHEET TITLE PROJECT TITLE SHEET NO. SCALE DATE ARCHITECT ANGELA SALLEY INTERIOR ELEVATIONS Scale: 1/2"=1'-0" CLIENT KITCHEN FLOATING BARAScale: 1/2"=1'-0" CLIENT KITCHEN COUNTERB Scale: 1/2"=1'-0" UNISEX RESTROOM LOCKERSCScale: 1/2"=1'-0" UNISEX RESTROOMDScale: 1/2"=1'-0" ADA UNISEX RESTROOMEScale: 1/2"=1'-0" ADA UNISEX RESTROOMF Scale: 1/2"=1'-0" ADA UNISEX RESTROOMGScale: 1/2"=1'-0" BREAK ROOMI Scale: 1/2"=1'-0" TYP. CORRIDOR ELEVATIONJ Scale: 1/2"=1'-0" BREAK ROOMH 34 A-44 SHEET TITLE PROJECT TITLE SHEET NO. SCALE DATE ARCHITECT ANGELA SALLEY DOOR & WINDOW SCHEDULE XX XX 35 TILE #MANUFACTURER STYLE / COLOR /GROUT SIZE REP / CONTACT LOCATION CORONADO STONE CORONADO STRIP STONE 1 12 "-2" x UP TO 23" LONG OUTSIDE AREAT1STONE VENEER FOR MAIN ENTRANCE T2 MCCARRAN HARDWOOD PLANKS WWW.CORONADO.COM -McCarran Engineered Hardwood ALL ROOMS ,HALLWAYSBREAK ROOM RECEPTION,OFFICE T3 TBD WOOD LOOK CERAMIC TILE --BREAK ROOM & BATHROOM FLOOR HARDWARE #MANUFACTURER MODEL SIZE / FINISH REP / CONTACT LOCATION ADVANTAGE ALL ROOM, BATHROOM,BREAK ROOM & UTILITY CLOSET DOORS H1 HS SERIES GRADE 2 PRIVACYFUNCTION CT LEVER, ADA COMPLIANT 2 14 " X 1 18 " US19 FLAT BLACK PLUMBING FIXTURES #MANUFACTURER MODEL SIZE / FINISH REP / CONTACT LOCATION KOHLER S: 21.31" X 16.38" X 6.81" F: Porcelain WWW.KOHLER.COM S: 4"X4"X1-1/16" PF 1 PF 2 THE BOLDLOCK OF KOHLERBRAZN 21-1/4" RECTANGULAR UNDERMOUNT BATHROOM SINK BATHROOM WITH SHOWER KOHLER KOHLER K26438-4-2MB "TONE" WALL MOUNT BATHROOM SINK FAUCET F: VIBRANT BRUSHEDMODERNE BRASS WWW.KOHLER.COM BATHROOM WITH NO SHOWER S: CIRCULAR 17"PF3 MISENO GRANITE VASSEL SINK F: GRANITE FERGUSON BATHROOM WITH NO SHOWER S: 25"X22"PF4 MTI BATHS BASICS ACRYLIC CXL LAUNDRYSINGLE BOWL WASHBOARD FRONT - WHITEMTLS110-WH F: WHITE WWW.MTIBATHS.COM CLIENT KITCHEN S: 21"X12 1/2"X 5 1/8"PF 5 DRYERBOX 22 GAUGE ALUMINIZED STEELWEIGHING 4.14 POUNDS EACH SKU DB-425 F: -ALUMINIZED STEEL WWW.DRYERBOX.COM BREAK ROOM S: -PF6 BELLERA®SEMI-PROFESSIONAL KITCHEN SINK FAUCET WITHTHREE-FUNCTION SPRAY HEAD K-29106-CP F: POLISHED CHROME CLIENT KITCHENKOHLERWWW.KOHLER.COM S: 3.9375" SPOUT HEIGHTPF7 PARALLEL® 1 GPM SINGLE HOLEBATHROOM FAUCET W/ POP-UP DRAIN ASSEMBLY F: VIBRANTBRUSHED NICKEL BATHROOM WITH SHOWERKOHLERWWW.KOHLER.COM PF 8 F: BRUSHED NICKEL (SPECIAL ORDER) SHOWERPEERLESSWWW.BUILD.COM PRECEPT PRESSURE BALANCED SHOWER SYSTEM W/ SHOWER HEAD, HAND SHOWER, SLIDE BAR, SHOWER ARM, HOSE &VALVE TRIM MODEL: PTT24247-BN WALL COVER #MANUFACTURER STYLE COLOR REP / CONTACT LOCATION MSI GLACIER STATUARY PORCELAIN PANELS 32"X96"WWW.MSISURFACES.COM GWB WITH SKIM COAT THROUGHOUT WC1 WC2 SHOWER WALLS T2 MSI HEXAGON-3"X3"SHOWER FLOOR EDEN DOLOMITE / WHITE GROUT WWW.MSISURFACES.COM BATHROOM WITH SHOWER -WHITE - COUNTERTOP #MANUFACTURER STYLE / COLOR SIZE REP / CONTACT LOCATION CAMBRIA TBD -WWW.CAMBRIAUSA.COM KITCHENS & BATHROOMSS SHOWER DOOR #MANUFACTURER MODEL SIZE/FINISH REP/CONTACT LOCATION LEVITY® SLIDING BATH DOOR,K-706002-L-SH WWW.KOHLER.COM BATHROOM W/ SHOWERSD1KOHLER 59-3/4" H X 56-5/8 -59-5/8" W, WITH 1/4" THICK CRYSTAL CLEARGLASS WHITE / WHITE GROUT APPLIANCES #MANUFACTURER MODEL SIZE / FINISH REP / CONTACT LOCATION GE PROFILE MICROWAVE H: 16.125", W: 29.875", D: 15.5625" F: STAINLESS STEEL WWW.HOMEDEPOT.COMA1 PROFILE 2.1 CU. FT. OVER THE RANGE MICROWAVE CLIENT KITCHEN & BREAK ROOM GE PROFILE MINI-FRIDGE H: 33.75", W: 23.5", D: 24.625" F: STAINLESS STEEL WWW.HOMEDEPOT.COMA2 PROFILE 23.5" 52 BOTTLE & 155 CAN BEVERAGE COOLER CLIENT KITCHEN &BREAK ROOM LG WASH TOWER H: 74.38", W: 27", D: 30.38" F: GRAPHITE STEEL WWW.HOMEDEPOT.COMA3 STACKED SMART LAUNDRY CENTER 4.5 CU. FT. FRONT LOADWASHER & 7.4 CU. FT. ELECTRIC DRYER BREAK ROOM WALKER ZANGER PORCELAIN SLAB -TREATMENT ROOMS 1 S2 MATCH HARDWOOD FLOORS ORIGINAL SLATPANEL LUXURY AMERICAN OAK ACOUSTIC SLAT WOOD WALL PANELS 25.2" X 94.5"WWW.THEWOODVENEERHUB.COMWC3 SELECT CORRIDOR WALLS S: 32"PF 9 SIGNATURE HARDWARE TILE INSERT DRAIN F: STAINLESS STEEL FERGUSON SHOWER TRIM #MANUFACTURER MODEL SIZE / FINISH REP / CONTACT LOCATION VINYL COVE BASE CORRIDORTR1S: 2" F: BLACK WOOD BASEBOARD MOULDING THROUGHOUTTR2S: 4" F: PAINTED WHITE MODEL: K-23472-4K-BN BRINKS ONE WAY EXIT DOORH2COMMERCIAL INDUSTRIAL DUTY ALUMINUM UNIVERSAL RIM REVERSIBLE EXIT DEVICE 32" MATTE BLACK A-45 SHEET TITLE PROJECT TITLE SHEET NO. SCALE DATE ARCHITECT ANGELA SALLEY FINISH SCHEDULE 36 2 1 211/2 " MA X . 1/4 " COUNTER SUNKSCREW @ 24" 0.C. EXTERIOR INTERIOR SLOPE2% MAX SHEET TITLE PROJECT TITLE SHEET NO. SCALE DATE ARCHITECT ANGELA SALLEY A-50 ARCHITECTURALDETAILS 37 INSULA T I O N WALL SUBSTR A T E STEP #1 STEP #2 INSULAT I O N WALL SUBSTRA T E CONTINUOUS BEAD OF ELEVATEWATER BLOCK (SEE NOTE #1) APPROPRIATE FASTENER4" (101.6 mm) O.C. MAX APPROPRIATETHERMOPLASTIC COATEDMETAL SCUPPER SLEEVE(SEE NOTE #1) 1-1/4" (31.75 mm) HOT DIPPEDGALVANIZED ROOF NAILS @4" (101.6 mm) O.C. MAX. NOTE:1. STEP #1 - APPLY CONTINUOUS BEAD OF ELEVATE WATER BLOCK CENTERED UNDERFASTENERS. ROUND ALL METAL CORNERS AND FASTEN METAL SCUPPER WITHAPPROPRIATE FASTENERS.2. STEP #2 - STRIP IN CORNERS OF SCUPPER WITH PRE-MOLDED ULTRAPLY TPO OR ELEVATEPVC INSIDE / OUTSIDE CORNERS. ULTRAPLY TPO FLASHING (UNSUPPORTED) MAY BE USEDIN LIEU OF PRE-MOLDED CORNERS FOR MAXIMUM WARRANTY OF 15 YEARS. PRE-MOLDEDTHERMOPLASTIC INSIDE/ OUTSIDE CORNERHEAT WELDED IN PLACE(SEE NOTE # 2) USEAPPROPRIATEBASE TIE-INDETAIL USE APPROPRIATETERMINATION THRU WALL SCUPPER WITH THERMOPLASTIC COATED METALINSTALLATION STEPS 1 & 2 10/10/2024 NOT TO SCALEMAXIMUM WARRANTY: 20 YEARS(800) 428-4511 www.holcimelevate.com DETAIL NO. TPM-S-05AISSUE / REVISION DATE:ACCEPTABLE SYSTEMS: ALL APPROPRIATETHERMOPLASTICMEMBRANE REPLACED DETAILSUT-S-05A & PVC-S-01A WARRANTY MEMBRANE REQUIREMENTS:15-YEARTPO - 45 MILPVC, PVC KEE, MAX PVC - 50 MIL20-YEARTPO - 60 MILPVC, PVC KEE, MAX PVC - 60 MIL MATERIAL: TPO / PVC / PVC KEE / MAX PVC NOTE:1.DO NOT MIX ELEVATE PVC/PVC KEEAND ELEVATE MAX PVC MEMBRANE.2.DO NOT MIX TPO AND PVCMEMBRANES. NOTE:1. STEP #1 - APPLY CONTINUOUS BEAD OF ELEVATE WATER BLOCK CENTERED UNDERFASTENERS. ROUND ALL METAL CORNERS AND FASTEN METAL SCUPPER WITHAPPROPRIATE FASTENERS.2. STEP #2 - STRIP IN CORNERS OF SCUPPER WITH PRE-MOLDED ULTRAPLY TPO OR ELEVATEPVC INSIDE / OUTSIDE CORNERS. ULTRAPLY TPO FLASHING (UNSUPPORTED) MAY BE USEDIN LIEU OF PRE-MOLDED CORNERS FOR MAXIMUM WARRANTY OF 15 YEARS. ELEVATE MAXPVC MEMBRANE SYSTEMS REQUIRE THE USE OF PRE-MOLDED ELEVATE MAX PVCCORNERS. SUBSTRATE ELEVATE INSULATION1/2" (12.7 mm) MIN.SEE NOTES SUBSTRATE INSULATION 1/2" (12.7 mm) MIN.SEE NOTES (SEE NOTES) 24" (619.6 mm) MIN. APPROPRIATE THERMOPLASTIC MEMBRANE WATER DAM COMPRESSION RING STRAINER BASKET COMPRESSION RING STRAINER BASKETOVERFLOWROOF DRAIN PRIMARYROOF DRAIN12" (304.8 mm)1" MAX.(25.4 mm) NOTE:1. REFER TO THE ELEVATETM WEBSITE FORTHE MOST CURRENT INFORMATION.2. HOLE IN MEMBRANE SHOULD EXTEND AMINIMUM OF 1/2" (12.7 mm) BEYONDCLAMPING RING AND SHOULD BE LARGERTHAN THE DIAMETER OF THE LEADER PIPE.3. INSULATION ADJACENT TO DRAIN TO BEAPPROPRIATE ELEVATE INSULATION WITHAPPROPRIATE BONDING SURFACE. CONTINUOUS BEAD OF ELEVATEWATER BLOCK (SEE NOTE #4) 4. ELEVATE WATER BLOCK MIN 1/2 OF10 OZ.(295 ml) TUBE PER 4" (101.6 mm) DRAIN.USE ADDITIONAL WATER BLOCK FORLARGER DRAINS.5. IN RE-ROOF APPLICATIONS:-REMOVE EXISTING FLASHING DOWN TOMETAL BOWL.-REPAIR OR REPLACE BROKEN DRAINSCOMPONENTS.-DRILL AND TAP BROKEN DRAINS BOLTSAND REPLACE IF NECESSARY. ACCEPTABLE ELEVATE MEMBRANEADHESIVE (ADHERED SYSTEMS ONLY) ROOF DRAIN WITH OVERFLOW ROOF DRAIN 10/10/2024 NOT TO SCALEMAXIMUM WARRANTY: 20 YEARS(800) 428-4511 www.holcimelevate.com DETAIL NO. TPM-D-04ISSUE / REVISION DATE:ACCEPTABLE SYSTEMS: ALL REPLACED DETAILSUT-D-04 & PVC-D-04 WARRANTY MEMBRANE REQUIREMENTS:15-YEARTPO - 45 MILPVC, PVC KEE, MAX PVC - 50 MIL20-YEARTPO - 60 MILPVC, PVC KEE, MAX PVC - 60 MIL MATERIAL: TPO / PVC / PVC KEE / MAX PVC NOTE:1.DO NOT MIX ELEVATE PVC/PVC KEEAND ELEVATE MAX PVC MEMBRANE.2.DO NOT MIX TPO AND PVCMEMBRANES. SUMP AREA FIELD SEAM REQUIREMENTS. A. IF FIELD SEAM EDGE IS WITHIN 9" (228.6 mm) OF DRAIN COMPRESSION RING, THERMOPLASTICTARGET PATCH REQUIRED. B. IF FIELD SEAM EDGE IS WITHIN 9" (228.6 mm) TO 18" (457.2 mm) OF DRAIN COMPRESSION RING, HEATWELD A LAYER OF ULTRAPLY TPO OR ELEVATE FLASHING (UNSUPPORTED) OR ELEVATE MAX PVC,CENTERED OVER SEAM EDGE. FLASHING MUST EXTEND 3" (76.2 mm) MIN. BEYOND EDGE OF SUMP. F.F. 2" MIN. CONCRETE CURB OVERFLOW DRAIN J-MOLDBACKER ROD & SEALANT AROUND ANNULUS, TYP J-MOLDROOF DRAIN 1'-0 " MIN 2X BLOCKING @ DRAINOPENING; NOTCH ASREQUIRED 8" 3X PTDF SILL PLATEPER STRUCTURALPLANS SHEET TITLE PROJECT TITLE SHEET NO. SCALE DATE ARCHITECT ANGELA SALLEY A-51 ARCHITECTURALDETAILS 38 2% MAX. SLOPE STUD WALL PER PLAN THIN SET CERAMICTILE PER TCA# W244 SEALANT REINFORCED MORTAR BED SHOWER MEMBRANE SLOPED FILL CRUSHED TILEOR STONE NEW DRAIN GRATE WEEP HOLES DEPRESSED CONC. SLAB 5/8" CEMENTIOUS BACKER BOARDOVER 4-MIL POLYETHYLENEMEMBRANE PER SPECIFICATIONS 3"MIN . 1" M I N . 1-3 / 4 " M A X . 3" MIN. TOPPING SLAB PERSTRUCTURAL PLANS CORNER BEADS INSULATION DOUBLE 3-5/8" X 20 GA STUD 5/8" BD. EACH SIDE 2 x CEILING JOISTS@16" 0.C STEEL CEILING ACCESS DOORW/ CONT CONCEALED HINGE &LOCKING LATCH 5/8" GYPSUM BOARD CEILING PANEL SHEET TITLE PROJECT TITLE SHEET NO. SCALE DATE ARCHITECT ANGELA SALLEY A-52 ARCHITECTURALDETAILS 39