Loading...
HomeMy WebLinkAbout04_O'Brien Residence Coastal Development Permit_PA2025-0116CITY OF NEWPORT BEACH ZONING ADMINISTRATOR STAFF REPORT October 16, 2025 Agenda Item No. 4 SUBJECT: O’Brien Residence (PA2025-0116) ▪Coastal Development Permit SITE LOCATION: 1624 West Ocean Front APPLICANT: John Walz OWNER: Toby O’Brien PLANNER: Laura Rodriguez, Assistant Planner 949-644-3216, lrodriguez@newportbeachca.gov LAND USE AND ZONING •General Plan Land Use Plan Category: Two Unit Residential (RT) •Zoning District: Two-Unit Residential (R-2) •Coastal Land Use Plan Category: Two Unit Residential (RT-D) (20.0-29.9 DU/AC) •Coastal Zoning District: Two-Unit Residential (R-2) PROJECT SUMMARY A coastal development permit (CDP) to demolish an existing 3,049 square-foot duplex and construct a new three-story 2,738-square-foot single unit dwelling with a 485-square-foot garage and an attached 928-square-foot accessory dwelling unit (ADU). The project also includes the installation of landscaping, hardscaping, and site walls. The project complies with all applicable development standards, and no deviations are requested. All improvements authorized by the CDP are within private property. RECOMMENDATION 1)Conduct a public hearing; 2)Find this project exempt from the California Environmental Quality Act (CEQA) pursuant to Section 15303 under Class 3 (New Construction or Conversion of Small Structures) of the CEQA Guidelines, California Code of Regulations, Title 14, Division 6, Chapter 3, because it has no potential to have a significant effect on the environment; and 3)Adopt Draft Zoning Administrator Resolution No. _ approving Coastal Development Permit No. PA2025-0116 (Attachment No. ZA 1). 1 O’Brien Residence (PA2025-0116) Zoning Administrator, October 16, 2025 Page 2 DISCUSSION Land Use and Development Standards •The subject property is in the R-2 Coastal Zoning District, which provides for single- unit residential development and is consistent with the City’s Coastal Land Use Plan, General Plan, and Zoning Code. A coastal development permit is required, and the property is not eligible for a waiver for de minimis development because the property is in the Coastal Commission Appeal Area. •The property currently consists of one legal lot developed with a duplex. The neighborhood is predominantly developed with two and three-story, single- and multi-unit-dwellings. The proposed design, bulk, and scale of the development are consistent with the existing neighborhood pattern of development and expected future development consistent with applicable development standards. Figure 1: Oblique Aerial Image of Neighborhood •The proposed single-unit dwelling and attached ADU conform to all applicable development standards, including floor area limit, setbacks, height, and off-street parking as evidenced by the project plans and illustrated in Table 1 below. Subject Property 2 O’Brien Residence (PA2025-0116) Zoning Administrator, October 16, 2025 Page 3 Table 1 – Development Standards Development Standard Standard Proposed Setbacks (min.) Front 9 feet 12 fee 3 inches Sides 3 feet 3 feet Rear N/A (20-foot rear alley) ~1 foot Allowable Floor Area (max.) 4,488 square feet 4,151 square feet Allowable 3rd Floor Area (max.) 448.8 square feet 442 square feet Allowable 3rd Floor Area & Covered (max.) 1122 square feet 701 square feet Open Space (min.) 33.6 square feet 372 square feet Parking (min.) 2-car garage 2-car garage Height (max.) 24-foot flat roof 29-foot sloped roof 24-foot flat roof 29-foot sloped roof •Pursuant to subsection 20.48.200.F.8(d)(ii) and 21.48.200.F.8(d)(ii) of the Newport Beach Municipal Code (NBMC), a walking route was included into the project’s plan set to demonstrate that additional parking for the ADU is not required if the Property is half a mile away from nearest major transit stop. Staff confirmed that the property is indeed within the half-mile distance. Hazards •The property is located in a developed area on the Balboa Peninsula and approximately 470 feet from the Mean High-Water Line of the ocean. •The finished floor elevation of the proposed single-unit dwelling is 12.17 feet North American Vertical Datum of 1988 (NAVD 88), which complies with the minimum 9.00-foot (NAVD 88) elevation standard for new structures. •A Coastal Hazards Report and Sea Level Rise Analysis were prepared by Skelly Engineering, dated April 14, 2025, for the project. The report concludes that the proposed project is reasonably safe from shoreline erosion due to the lack of waves or wakes that can erode sand from the beach. The report also concludes that the project will be reasonably safe from future sea level rise assuming an increase from 1.3 feet (likely scenario) to 4.5 feet (unlikely scenario) which accounts for future extreme ocean water level in the range of 9.0 feet NAVD 88 to 12.2 feet NAVD 88. The finished floor elevation of the first floor of the proposed structure is 12.17 feet NAVD 88, which complies with the minimum 9.0-foot NAVD 88 elevation standard for new structures and is above the “likely” maximum future ocean water elevation. Overall, the report concludes that the Project will not be affected by the projected 75- year sea level rise due to its distance from the shoreline. •The property is in an area known for the potential of seismic activity and liquefaction. All projects are required to comply with the California Building Code (CBC) and 3 O’Brien Residence (PA2025-0116) Zoning Administrator, October 16, 2025 Page 4 Building Division standards and policies. Geotechnical investigations specifically addressing liquefaction are required to be reviewed and approved before the issuance of a building permit. Permit issuance is also contingent on the inclusion of design mitigation identified in the investigations. Construction plans are reviewed for compliance with approved investigations and CBC before building permit issuance. Water Quality •The property is located approximately 470 feet from the Mean High-Water Line of the beach. Under Section 21.35.030 (Construction Pollution Prevention Plan) of the NBMC, a Construction Pollution Prevention Plan (CPPP) is required to implement temporary Best Management Practices (BMPs) during construction to minimize erosion and sedimentation and to minimize pollution of runoff and coastal waters derived from construction chemicals and materials. A CPPP has been provided and construction plans and activities will be required to adhere to the CPPP. •Under Section 21.35.050 (Water Quality and Hydrology Plan) of the NBMC, due to the proximity of the development to the shoreline and the development containing more than 75% of impervious surface area, a preliminary Water Quality and Hydrology Plan (WQHP) is required. A preliminary WQHP has been prepared for the project by Toal Engineering, Inc. dated December 4, 2023. The WHQP includes a polluted runoff and hydrologic site characterization, a sizing standard for BMPs, the use of a LID approach to retain the design storm runoff volume on-site, and documentation of the expected effectiveness of the proposed BMPs. The final priority WQHP shall be reviewed and approved by the Building Division during plan check. •The project design addresses water quality with a construction erosion control plan and a post-construction drainage system that includes drainage and percolation features designed to retain dry weather runoff and minor rain event runoff on-site. Any water not retained on-site is directed to the City’s storm drain system. Public Access and Views •The project site is located between the nearest public road and the sea or shoreline. Section 21.30A.040 (Determination of Public Access/Recreation Impacts) of the NBMC requires that the provision of public access bears a reasonable relationship between the requirement and the project’s impact and be proportional to the impact. In this case, the project replaces an existing duplex located on a standard R-2 lot with a new single-unit dwelling and attached accessory dwelling unit. Therefore, the project does not involve a change in land use, density, or intensity that will result in increased demand for public access and recreation opportunities. Furthermore, the project is designed and sited (appropriate height, setbacks, etc.) so as not to block or impede existing public access opportunities. 4 O’Brien Residence (PA2025-0116) Zoning Administrator, October 16, 2025 Page 5 •The project is not located near Coastal Viewpoint or Coastal View Road as identified in the Coastal Land Use Plan (CLUP). The nearest coastal viewpoint is Veterans Memorial Park, approximately 600 feet northeast of the property. This viewpoint is not visible from the property, and the project is also not located between Marina Park or the bay. Therefore, the project would not obscure views from these public areas. •Vertical access to the beach is available at the 16th and 17th Street end from West Balboa Boulevard. The property is located adjacent to the West Ocean Front boardwalk, which serves as lateral access and provides a path along the beach for pedestrian and bicycle use. The project does not include any features that would obstruct access along these routes. •As a beachfront property, the front elevation will be visible from the beach. While the property only requires a nine-foot front setback, the project provides a setback of approximately 12 feet. This enlarged setback area helps enhance the visual quality of the coast as viewed through the 17th Street street-end from West Balboa Boulevard, as well as from the West Ocean Front Boardwalk and beach beyond. Additionally, the project maintains a building envelope consistent with the existing neighborhood pattern of development and complies with all applicable local coastal program (LCP) development standards, including all third-floor standards of the NBMC which limits the size and location of the third floor. Therefore, the project does not contain any unique features that could degrade the visual quality of the coastal zone. ENVIRONMENTAL REVIEW This project is exempt from the California Environmental Quality Act (CEQA) pursuant to Section 15303 under Class 3 (New Construction or Conversion of Small Structures) of the CEQA Guidelines, California Code of Regulations, Title 14, Division 6, Chapter 3 because it has no potential to have a significant effect on the environment. Class 3 consists of construction and location of limited numbers of new, small facilities or structures; installation of small equipment and facilities in small structures; and the conversion of existing small structures from one use to another where only minor modification are made in the exterior of the structures. Class 3 also exempts the demolition of up to three single-unit dwellings and additions of up to 10,000 square feet to existing structures and allows the construction or conversion of up to three single-unit dwellings. In this case, the project consists of the demolition of an existing duplex and the construction of a new 2,738-square-foot single-unit dwelling with a 485-square-foot two- car garage and an attached 928-square-foot ADU and therefore qualifies within this exemption. 5 O’Brien Residence (PA2025-0116) Zoning Administrator, October 16, 2025 Page 6 There are no known exceptions listed in CEQA Guidelines Section 15300.2 that would invalidate the use of this exemption. The project location does not impact an environmental resource of hazardous or critical concern, does not result in cumulative impacts, does not have a significant effect on the environment due to unusual circumstances, does not damage scenic resources within a state scenic highway, is not a hazardous waste site, and is not identified as a historical resource. PUBLIC NOTICE Notice of this public hearing was published in the Daily Pilot, mailed to all owners and residential occupants of property within 300 feet of the boundaries of the site (excluding intervening rights-of-way and waterways), including the applicant, and posted on the subject property at least 10 days before the scheduled hearing, consistent with the provisions of the Municipal Code. Additionally, the item appeared on the agenda for this meeting, which was posted at City Hall and on the city website. APPEAL PERIOD: This action shall become final and effective 14 days following the date the Resolution is adopted unless within such time an appeal or call for review is filed with the Community Development Director by the provisions of Title 21 (Local Coastal Program [LCP] Implementation Plan) of the Newport Beach Municipal Code. Final action taken by the City may be appealed to the Coastal Commission in compliance with Section 21.64.035 (Appeal to the Coastal Commission) of the City’s certified LCP and Title 14 California Code of Regulations, Sections 13111 through 13120, and Section 30603 of the Coastal Act. For additional information on filing an appeal, contact the Planning Division at 949-644-3200. Prepared by: Laura Rodriguez, Assistant Planner DL/lr Attachments: ZA 1 Draft Resolution ZA 2 Vicinity Map ZA 3 Project Plans 6 Attachment No. ZA 1 Draft Resolution 7 RESOLUTION NO. ZA2025-### A RESOLUTION OF THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH APPROVING A COASTAL DEVELOPMENT PERMIT TO DEMOLISH AN EXISTING DUPLEX AND CONSTRUCT A NEW THREE-STORY SINGLE-UNIT DWELLING WITH AN ATTACHED ACCESSORY DWELLING UNIT AND ATTACHED TWO-CAR GARAGE LOCATED AT 1624 WEST OCEAN FRONT (PA2025-0116) THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH HEREBY FINDS AS FOLLOWS: SECTION 1. STATEMENT OF FACTS. 1.An application was filed by John Walz (Applicant), concerning property located at 1624 West Ocean Front and legally described as Lot 12 of Block 16 of Section B Newport Beach Tract (Property), requesting approval of a coastal development permit (CDP). 2.The Applicant requests a CDP to demolish an existing 3,049-square-foot duplex and construct a new three-story 2,738-square-foot single-unit dwelling with a 485-square-foot garage and an attached 928-square-foot accessory dwelling unit (ADU). The project also includes the installation of landscaping, hardscaping, and site walls. The project complies with all applicable development standards, and no deviations are requested. All improvements authorized by the CDP are within private property (Project). 3.The Property is designated Two Unit Residential (RT) by the General Plan Land Use Element and is located within the Two-Unit Residential (R-2) Zoning District. 4.The Property is located within the coastal zone. The Coastal Land Use Plan (CLUP) category is Two Unit Residential (RT-D) and it is located within the Two-Unit Residential (R-2) Coastal Zoning District. 5.A public hearing was held on October 16, 2025, online via Zoom. A notice of the time, place, and purpose of the hearing was given by the Newport Beach Municipal Code (NBMC). Evidence, both written and oral, was presented to and considered by the Zoning Administrator at this hearing. SECTION 2. CALIFORNIA ENVIRONMENTAL QUALITY ACT DETERMINATION. 1.This Project is categorically exempt pursuant to Title 14 of the California Code of Regulations Section 15303, Division 6, Chapter 3, Guidelines for Implementation of the California Environmental Quality Act (CEQA) under Class 3 (New Construction or Conversion of Small Structures) because it has no potential to have a significant effect on the environment. 2.Class 3 consists of construction and location of limited numbers of new, small facilities or structures; installation of small equipment and facilities in small structures; and the conversion of existing small structures from one use to another where only minor 8 Zoning Administrator Resolution No. ZA2025-### Page 2 of 9 modifications are made in the exterior of the structures. Class 3 also exempts the demolition of up to three single-unit dwellings and additions of up to 10,000 square feet to existing structures and allows the construction or conversion of up to three single-unit dwellings. In this case, the Project consists of the demolition of an existing duplex and the construction of a new 2,738-square-foot single-unit dwelling with a 485-square-foot two-car garage and an attached 928-square-foot ADU. 3.The exceptions to this categorical exemption under Section 15300.2 are not applicable. The Project does not impact an environmental resource of hazardous or critical concern, does not result in cumulative impacts, does not have a significant effect on the environment due to unusual circumstances, does not damage scenic resources within a state scenic highway, is not a hazardous waste site, and is not identified as a historical resource. SECTION 3. REQUIRED FINDINGS. In accordance with Section 21.52.015 (Coastal Development Permits, Findings, and Decision) of the NBMC, the following findings, and facts in support of such findings are set forth: Finding: A.Conforms to all applicable sections of the certified Local Coastal Program (LCP). Facts in Support of Finding: 1.The Project complies with applicable residential development standards including, but not limited to, floor area limitation, setbacks, height, and parking. a.The maximum floor area limitation is 4,488 square feet and the proposed floor area is 4,151 square feet. b.The Project provides the minimum required setbacks, which are 12 feet from the property line along West Ocean Front and three feet from each side property line. There is no setback from the rear property line along the alley. c.The highest flat roof element does not exceed the maximum 24 feet from the established grade, which is 11.46 feet per the North American Vertical Datum of 1988 (NAVD 88) and the highest sloping roof does not exceed 29 feet from the established grade, which complies with the maximum height requirements. d.The Project includes garage parking for a total of two vehicles, complying with the minimum two-car garage parking requirement for single-unit dwellings with less than 4,000 square feet of habitable floor area. Pursuant to subsection 20.48.200.F.8(d)(ii) and 21.48.200.F.8(d)(ii) of the NBMC, a walking route was included into the project’s plan set to demonstrate that additional parking for the ADU is not required if the Property is half a mile away from nearest major transit stop. Staff confirmed that the property is indeed within the half-mile distance. 9 Zoning Administrator Resolution No. ZA2025-### Page 3 of 9 2. A Coastal Hazards Report and Sea Level Rise Analysis was prepared by Skelly Engineering, dated April 14, 2025, for the Project. The report utilizes the latest adopted Sea Level Rise Guidance: 2024 Update provided by the State of California and concludes that the Project is reasonably safe from shoreline erosion due to the lack of waves or wakes that can erode sand from the beach. The report also concludes that the Project will be reasonably safe from future sea level rise, assuming an increase from 1.3 feet (likely scenario) to 4.5 feet (unlikely scenario) which accounts for future extreme ocean water level in the range of 9.0 feet NAVD 88 to 12.2 feet NAVD 88. The finished floor elevation of the first floor of the proposed structure is 12.17 feet NAVD 88, which complies with the minimum 9.0-foot NAVD 88 elevation standard for new structures and is above the “likely” maximum future ocean water elevation. Overall, the report concludes that the Project will not be affected by the projected 75-year sea level rise due to its distance from the shoreline. 3. The Property is in an area known for the potential of seismic activity and liquefaction. All projects are required to comply with the California Building Code (CBC) and Building Division standards and policies. Geotechnical investigations specifically addressing liquefaction are required to be reviewed and approved before the issuance of building permits. Permit issuance is also contingent on the inclusion of design mitigation identified in the investigations. Construction plans are reviewed for compliance with approved investigations and CBC before building permit issuance. 4. The Property is located 470 feet from the Mean High-Water Line of the ocean. A Construction Pollution Prevention Plan (CPPP) was provided to implement temporary Best Management Practices (BMPs) during construction to minimize erosion and sedimentation and to minimize pollution of runoff and coastal waters derived from construction chemicals and materials. The Project design also addresses water quality through the inclusion of a post-construction drainage system that includes drainage and percolation features designed to retain dry weather and minor rain event runoff on-site. Any water not retained on-site is directed to the City’s storm drain system. 5. Pursuant to Section 21.35.050 (Water Quality and Hydrology Plan) of the NBMC, due to the proximity of the development to the shoreline and the development containing more than 75% of impervious surface area, a Water Quality and Hydrology Plan (WQHP) is required. A preliminary WQHP has been prepared for the Project by Total Engineering, Inc. dated, December 4, 2023. The WQHP includes a polluted runoff and hydrologic site characterization, a sizing standard for BMPs, the use of a Low Impact Development (LID) approach to retain the design storm runoff volume on-site, and documentation of the expected effectiveness of the proposed BMPs. The final priority WQHP shall be reviewed and approved by the Building Division during plan check. 6. Proposed landscaping complies with Section 21.30.075 (Landscaping) of the NBMC. A condition of approval is included that requires drought-tolerant species. Before the issuance of building permits, the final landscape plans will be reviewed to verify invasive species are not planted. 7. The Project is not located near Coastal Viewpoint or Coastal View Road as identified in the Coastal Land Use Plan (CLUP). The nearest coastal viewpoint is Veterans Memorial 10 Zoning Administrator Resolution No. ZA2025-### Page 4 of 9 Park, approximately 600 feet northeast of the Property. This viewpoint is not visible from the Property. Therefore, the Project would not obscure views from these public areas. 8. As a beachfront property, the front elevation will be visible from the beach. While the Property only requires a nine-foot front setback, the Project provides a setback of approximately 12 feet. This enlarged setback area helps enhance the visual quality of the coast as viewed through the 17th Street street-end from West Balboa Boulevard, as well as from the West Ocean Front Boardwalk and beach beyond. The Project also complies with all applicable LCP development standards, including all third-floor standards of the NBMC which limits the size and location of the third floor. Therefore, the Project is not anticipated to degrade the visual quality of the coastal zone. Finding: B. Conforms with the public access and public recreation policies of Chapter 3 of the Coastal Act if the project is located between the nearest public road and the sea or shoreline of any body of water located within the coastal zone. Fact in Support of Finding: 1. The Property is located between the nearest public road and the sea or shoreline. Section 21.30A.040 (Determination of Public Access/Recreation Impacts) of the NBMC requires that the provision of public access bears a reasonable relationship between the requirement and the Project’s impact and be proportional to the impact. In this case, the Project replaces an existing duplex located on a standard R-2 lot with a new single-unit dwelling and attached accessory dwelling unit. Therefore, the Project does not involve a change in land use, density, or intensity that will result in increased demand for public access and recreation opportunities. Furthermore, the Project is designed and sited (appropriate height, setbacks, etc.) so as not to block or impede existing public access opportunities. 2. The Project is located near a Public Beach Access point as identified in the CLUP. Vertical access to the beach is available at the 16th and 17th Street end from West Balboa Boulevard. The Property is located adjacent to the West Ocean Front boardwalk, which serves as lateral access and provides a path along the beach for pedestrian and bicycle use. The Project does not include any features that would obstruct access along these routes. 3. The Property provides vehicular access from 16th and 17th Street as well as West Ocean Front Alley, which is not proposed to change with the Project. SECTION 4. DECISION. NOW, THEREFORE, BE IT RESOLVED: 1. The Zoning Administrator of the City of Newport Beach hereby finds this Project is categorically exempt from the California Environmental Quality Act pursuant to Section 15303 under Class 3 (New Construction or Conversion of Small Structures) of the CEQA 11 Zoning Administrator Resolution No. ZA2025-### Page 5 of 9 Guidelines, California Code of Regulations, Title 14, Division 6, Chapter 3 because it has no potential to have a significant effect on the environment. 2. The Zoning Administrator of the City of Newport Beach hereby approves the Coastal Development Permit No. PA2025-0116 subject to the conditions outlined in Exhibit “A,” which is attached hereto and incorporated by reference. 3. This action shall become final and effective 14 days following the date this Resolution was adopted unless within such time an appeal or call for review is filed with the Community Development Director by the provisions of Title 21 (Local Coastal Program (LCP) Implementation Plan), of the Newport Beach Municipal Code. Final action taken by the City may be appealed to the Coastal Commission in compliance with Section 21.64.035 (Appeal to the Coastal Commission) of the City’s certified LCP and Title 14 California Code of Regulations, Sections 13111 through 13120, and Section 30603 of the Coastal Act. PASSED, APPROVED, AND ADOPTED THIS 16TH DAY OF OCTOBER 2025. _____________________________________ Benjamin M. Zdeba, AICP, Zoning Administrator 12 Zoning Administrator Resolution No. ZA2025-### Page 6 of 9 EXHIBIT “A” CONDITIONS OF APPROVAL (Project-specific conditions are in italics) 1. The development shall be in substantial conformance with the approved site plan, floor plans, and building elevations stamped and dated with the date of this approval (except as modified by applicable conditions of approval). 2. Prior to final building permit inspection, an agreement in a form approved by the City Attorney between the property owner and the City shall be executed and recorded waiving rights to the construction of future shoreline protection devices to address the threat of damage or destruction from waves, erosion, storm conditions, landslides, seismic activity, bluff retreat, sea level rise, or other natural hazards that may affect the property, or development of the property, today or in the future. The agreement shall be binding against the property owners and successors and assigns. 3. Prior to the issuance of a building permit, the property owner shall submit a notarized signed letter acknowledging all hazards present at the site, assuming the risk of injury or damage from such hazards, unconditionally waiving any claims of damage against the City from such hazards, and to indemnify and hold harmless City, its City Council, its boards and commissions, officials, officers, employees, and agents from and against any claims, demands, obligations, damages, actions, causes of action, suits, losses, judgments, fines, penalties, liabilities, costs, and expenses (including without limitation, attorney’s fees, disbursements, and court costs) of every kind and nature whatsoever which may arise from or in any manner relate (directly or indirectly) to City’s approval of the development. This letter shall be scanned into the plan set before building permit issuance. 4. Prior to the issuance of a building permit, the Applicant shall pay any unpaid administrative costs associated with the processing of this application to the Planning Division. 5. Prior to the issuance of a building permit, the Applicant shall submit a final construction erosion control plan. The plan shall be subject to review and approval by the Building Division. 6. Prior to the issuance of a building permit, the Applicant shall submit a final drainage and grading plan. The plan shall be subject to review and approval by the Building Division. 7. Prior to the issuance of a building permit, a copy of the Resolution, including conditions of approval Exhibit “A” shall be incorporated into the Building Division and field sets of plans. 8. Prior to the issuance of a building permit, the Applicant shall submit a final landscape and irrigation plan. These plans shall incorporate drought-tolerant plantings, non- invasive plant species, and water-efficient irrigation design. The plans shall be approved by the Planning Division. 13 Zoning Administrator Resolution No. ZA2025-### Page 7 of 9 9.Prior to the issuance of a building permit, the final WQHP/WQMP shall be reviewed and approved by the Building Division. The implementation shall comply with the approved CPPP and WQHP/WQMP and any changes could require separate review and approval by the Building Division. 10.This approval does not authorize any new or existing improvements (including landscaping) on California Coastal Permit Jurisdiction, State tidelands, public beaches, or the public right-of-way. Any improvements located on tidelands, submerged lands, and/or lands that may be subject to the public trust shall require a coastal development permit (CDP) approved by the California Coastal Commission (CCC). Before the issuance of building permits, the applicant shall provide a copy of said CDP or CDP waiver or documentation from the CCC that subject improvements are not subject to the permit requirements of the Coastal Act and/or not located within the permit jurisdiction of the CCC. 11.No demolition or construction materials, equipment debris, or waste, shall be placed or stored in a location that would enter the sensitive habitat, receiving waters, or storm drains or result in impacts to environmentally sensitive habitat areas, streams, the beach, wetlands or their buffers. No demolition or construction materials shall be stored on public property. 12.This Coastal Development Permit does not authorize any development seaward of the private property. 13.The Applicant is responsible for compliance with the Migratory Bird Treaty Act (MBTA). In compliance with the MBTA, grading, brush removal, building demolition, tree trimming, and similar construction activities shall occur between August 16 and January 31, outside of the peak nesting period. If such activities must occur inside the peak nesting season from February 1 to August 15, compliance with the following is required to prevent the taking of native birds under MBTA: A.The construction area shall be inspected for active nests. If birds are observed flying from a nest or sitting on a nest, it can be assumed that the nest is active. Construction activity within 300 feet of an active nest shall be delayed until the nest is no longer active. Continue to observe the nest until the chicks have left the nest and activity is no longer observed. When the nest is no longer active, construction activity can continue in the nest area. B.It is a violation of state and federal law to kill or harm a native bird. To ensure compliance, consider hiring a biologist to assist with the survey for nesting birds, and to determine when it is safe to commence construction activities. If an active nest is found, one or two short follow-up surveys will be necessary to check on the nest and determine when the nest is no longer active. 14.Best Management Practices (BMPs) and Good Housekeeping Practices (GHPs) shall be implemented before and throughout the duration of construction activity as designated in the Construction Erosion Control Plan. 14 Zoning Administrator Resolution No. ZA2025-### Page 8 of 9 15. The discharge of any hazardous materials into storm sewer systems or receiving waters shall be prohibited. Machinery and equipment shall be maintained and washed in confined areas specifically designed to control runoff. A designated fueling and vehicle maintenance area with appropriate berms and protection to prevent spillage shall be provided as far away from storm drain systems or receiving waters as possible. 16. Debris from demolition shall be removed from work areas each day and removed from the project site within 24 hours of the completion of the project. Stockpiles and construction materials shall be covered, enclosed on all sites, not stored in contact with the soil, and located as far away as possible from drain inlets and any waterway. 17. Trash and debris shall be disposed of in proper trash and recycling receptacles at the end of each construction day. Solid waste, including excess concrete, shall be disposed of in adequate disposal facilities at a legal disposal site or recycled at a recycling facility. 18. Revisions to the approved plans may require an amendment to this Coastal Development Permit or the processing of a new coastal development permit. 19. The Project is subject to all applicable City ordinances, policies, and standards unless specifically waived or modified by the conditions of approval. 20. The Applicant shall comply with all federal, state, and local laws. A material violation of any of those laws in connection with the use may be caused by the revocation of this Coastal Development Permit. 21. This Coastal Development Permit may be modified or revoked by the Zoning Administrator if determined that the proposed uses or conditions under which it is being operated or maintained are detrimental to the public health, and welfare or materially injurious to the Property or improvements in the vicinity or if the Property is operated or maintained to constitute a public nuisance. 22. All landscape materials and irrigation systems shall be maintained by the approved landscape plan. All landscaped areas shall be maintained in a healthy and growing condition and shall receive regular pruning, fertilizing, mowing, and trimming. All landscaped areas shall be kept free of weeds and debris. All irrigation systems shall be kept operable, including adjustments, replacements, repairs, and cleaning as part of regular maintenance. 23. Construction activities shall comply with Section 10.28.040 (Construction Activity – Noise Regulations) of the NBMC, which restricts hours of noise-generating construction activities that produce noise to between the hours of 7:00 a.m. and 6:30 p.m., Monday through Friday. Noise-generating construction activities are not allowed on Saturdays, Sundays, or Holidays. 24. All noise generated by the proposed use shall comply with the provisions of Chapter 10.26 (Community Noise Regulations) of the NBMC and other applicable noise control requirements of the NBMC. 15 Zoning Administrator Resolution No. ZA2025-### Page 9 of 9 25.Should the property be sold or otherwise come under different ownership, any future owners or assignees shall be notified of the conditions of this approval by the current property owner or agent. 26.This Coastal Development Permit shall expire unless exercised within 24 months from the date of approval as specified in Section 21.54.060 (Time Limits and Extensions) of the NBMC, unless an extension is otherwise granted. 27.To the fullest extent permitted by law, the applicant shall indemnify, defend and hold harmless the City, its City Council, its boards and commissions, officials, officers, employees, and agents from and against any claims, demands, obligations, damages, actions, causes of action, suits, losses, judgments, fines, penalties, liabilities, costs, and expenses (including without limitation, attorney’s fees, disbursements, and court costs) of every kind and nature whatsoever which may arise from or in any manner relate (directly or indirectly) to the City’s approval of O’Brien Residence including but not limited to, Coastal Development Permit (PA2025-0116) This indemnification shall include, but not be limited to, damages awarded against the City, if any, costs of suit, attorney’s fees, and other expenses incurred in connection with such claim, action, causes of action, suit, or proceeding whether incurred by the applicant, City, and/or the parties initiating or bringing such proceeding. The Applicant shall indemnify the City for all the City's costs, attorneys' fees, and damages, which the City incurs in enforcing the indemnification provisions outlined in this condition. The Applicant shall pay to the City upon demand any amount owed to the City under the indemnification requirements prescribed in this condition. Fire Division 28.A residential fire sprinkler system complying with 2022 NFPA13D shall be required. 29.A minimum 36-inch unobstructed walk path from the front to the rear of the Property shall be required for emergency access. Public Works Division 30.The existing wall and pilasters within the West Ocean Front right of way shall be removed, and a sidewalk installation to match the existing Ocean Front walkway shall be required. 31.A new sewer clean out on the existing sewer lateral per City Standard 406 shall be required. 32.No encroachments within the alley right of way, including foundation, shall be permitted. 16 Attachment No. ZA 2 Vicinity Map 17 VICINITY MAP Coastal Development Permit No. PA2025-0116 1624 West Ocean Front Subject Property 18 O’Brien Residence (PA2025-0116) Zoning Administrator, October 16, 2025 Page 10 Attachment No. ZA 3 Project Plans 19 (N 7 9 ° 1 9 ' 3 3 " W 3 0 . 0 0 ') (N 10°40'27" E 102.50') (N 10°40'27" E 102.50') 0') (N 7 9 ° 1 9 ' 3 3 " W 3 0 . 0 0 0) 00 030 WW"W 3'39°9 N( 0000 33 WWWW 33'' 11 999 N(((( 000 3 WWW 3 99 97N( WW 333911 9997NNN( )))000 33 W 00 (9.9 1 F S ) (10.27FS) (12.09FS)( (14.51TW)(13.72FS) (10.77FS)(11.78FS) (11 . 1 7 F S ) (11.56FS)(11.86FS) (10.08FS) (10. 5 9 G F ) (31.81)TOR (39. 3 6 ) ((3(39(39(39(39 TO R TORR TO R TOTO R TO R (36. 0 4 ) TOR 57TW577T (14.545(1(((1(1(1((1((1(1((11(((1(1(1(1(1(11(1((11(((1(1(1(1(((1(1414(1(1(1(1((1((14(1(1 TW)W)W)W)TWW) (13.84FS) FS)) (13.84FS(13. 4FS884433((1133(11(11333388(13(133833.884384 (1338(13383.8(1133338.8884844 (1(1333333.3388(113(1338338.81(1313(1338.88484 (1(133338.88884844 ((13133333.88443.(13843(184383813 43.8(13843(83484884.88383313(11(188.33313(13(184( (11.46FS) (13.26FS)(132266FFSS)(11 (13.26TW ) ) (10.75FS)5F70071010.0(710(S)SS)S)S)FS W M(10.18 F S ) (10. 3 3 F S ) (10.43FS)10. FFFFFSFFS3F (((( LOT 12 LO T 1 2 STORYBUILDING 2 STOR BU IL D 2 STORY BU IL D I N G OC E A N F R O N T W E S T TTTTTSST ESSEEWEEEE TTTTTTTTTSSSSEEEE TTTTTTTTSSSSSEEEEEWW TTTTTTTSSSSSSSEEEEEW A T AL L E Y 1 STOR BU IL D UTILITY EDISON BOX BOX GAR A GE GMGM 2ND STORYBUILDING LINE (12.05FF)(11.08FS) (10.93FS)S)(S99903990 (14.14FF) (14. 1 F S ) ECKECK DEDDDEELIN E LIN ENE LINLINLI PA L M LM PA LL (22.79)222277979)9)79)79)79)(2(222222(222(222 )) (( )) ((((DECKDDEDECKK DECCKKK DECCKDEDECCKDDDDDD (37.61)()RIDGE (37.69)(TOP OF RAILINGT (14.02FF)14.0144(14 (34.80)(3480)DECKDDECKKDECKDECKDECK (12.73 F S ) ((127733FFSS) (12 . 0 8 F S ) )F 02( )F . ( 8222( F 22 (12 . 1 1 F S ) (13 . 9 2 F S ) (13 . 9 2 F S ) (13 9 2 F S ) (13. 8 7 ((13387 (13. 8 7 F S ) FS) (13. 8 7 F S ) FS) (13. 8 7 87F (((111(1((13. 8 7 F S ) ( ) (((( (13. 7 0 F S ) ((1133770 F FSS) (11. 8 9 F S ) (11. 6 5 F S ) (11.36FS)(10.90FS)(1(10.57FS) (11. 3 5 F S ) (13. 2 6 F S ) (13.55FS) (11. 8 5 F S ) (11. 7 9 F S ) (11.75FS)75F (9.8 5 F S ) (9.88FS) ) (9.84FS) (9.42FL) (9.5 0 F L ) (9.59FL) (11.54FS)1 SF4FSFF4(12.61FS)2 F122211)))22 S1162 DE C K DE C K DE C K LILILLLLLNENE IN ENE INE (10.46FS) (10. 0 0 F S ) XX XXXXXXXXX XXXXXXXXXXXXX XX XXXXXXX XX PLA S T I C FEN C E XX XXXXXXXXX XXXXXXXXX XXXX XX XXXXXX XXXX XXXXXXXXXXXXXX XX XX 2.1 3.2 3.0 2.72.727 3.0 3.1 4.9 0.7 9.5 12.7 8.888.88.88 PR OPE R T Y LINE PR O P E R T Y LIN E PR OPER T Y LINE PR O P E R T Y TYTY PR O P E R T RO P E R T PR O P E R T TRTT OOOLIN E LLINNE LLINNE LLINNEE LLLLININNNEEEE LLIINNNNEEEE LILNINNENEEE LLLINLNIN ENEEE LLIINNNNEEEE LLLLINNNNEEEE LLILNLNI ENENEE LLINLNLNE IN ENNEEEEENENNINLILLL ENEENNE INNLINLLL EEEENNNNLILILL EEEENNNNLILILL SEA R C H E D , FOUND N O T H I N G SEA R C H E D , FOUND N O T H I N GSEA R C H E D , FO U N D N O T H I N G H SEA R C H E D , SESAFO U N D N O T H I N G U PIL A S T E R LP RRTESTAS RER STSTS LALA ER STSTA PI ) CEN T E R LIN E DIRTDDIRRT DIRT (9.8 9 F S ) (10 . 6 5 F S ) (10.36FS)(S)6F6F6F336F3636F36360 (12.78 T W ) 12 )WWT88WTTTWW8878WWWTT78(13.32T W )2TW)2T23((3(13(1((3( WWWWWWW)W)W)WWWWW))W (( (11. 8 2 F S ) ..1.11111((((1(1(1(11(11(11111 (14.63TW)(14(1(14.63 WTWT36666WWW63T4.6 WW636666W)TW33.. (12 . 1 4 F S ) 13. 9 0 F S ) ) 13 9 0 F S ) (1(11 (14.05FS) (11.67FS) (11. 0 9 F S ) (11.0FS) 3'-0 " POINT #1: 10.23 FSPOINT #2: 9.89 FSPOINT #3: 12.81 FSPOINT #4: 12.89 FS SITE PLAN 1 ROOF AND SITE 1/8"=1'-0"A_0.1 (E)NEIGHBOR RESIDENCE LOCATION MAP N GENERAL SITE NOTES: 1. EMPLOY NEWPORT BEACH STANDARD EROSION CONTROL MEASURESTHROUGHOUT THE CONSTRUCTION PROCESS. 2. A PUBLIC WORKS DEPARTMENT ENCROACHMENT PERMIT INSPECTION ISREQUIRED BEFORE THE BUILDING DEPARTMENT PERMIT FINAL CAN BEISSUED. AT THE TIME OF PUBLIC WORKS DEPARTMENT INSPECTION, IFANY OF THE EXISTING PUBLIC IMPROVEMENTS SURROUNDING THE SITEIS DAMAGED, NEW CONCRETE SIDEWALK, CURB AND GUTTER, ANDALLEY/STREET PAVEMENT WILL BE REQUIRED. ADDITIONALLY, IFEXISTING UTILITIES INFRASTRUCTURE ARE DEEMED SUBSTANDARD, ANEW 1-INCH WATER SERVICE, WATER METER BOX, SEWER LATERALAND/OR CLEANOUT WITH BOX AND LID WILL BE REQUIRED. 100% OF THECOST SHALL BE BORNE BY THE PROPERTY OWNER (MUNICIPAL CODES14.24.020 AND 14.08.030). SAID DETERMINATION AND THE EXTENT OFTHE RECONSTRUCTION WORK SHALL BE MADE AT THE DISCRETION OFTHE PUBLIC WORKS INSPECTOR. CONTRACTOR IS RESPONSIBLE TOMAINTAIN THE PUBLIC RIGHT OF WAY AT ALL TIMES DURING THECONSTRUCTION PROJECT. A STOP WORK NOTICE MAY BE ISSUED FORANY DAMAGE OR UNMAINTAINED PORTION OF THE PUBLIC RIGHT OFWAY. 3. ALL PRIVATE IRRIGATION SPRINKLER HEADS SHALL BE INSTALLED ANDPOSITIONED IN A MANNER THAT WILL NOT CAUSE IRRIGATIONOVERSPRAY ONTO THE PUBLIC RIGHT-OF-WAY. 4. AN APPROVED ENCROACHMENT PERMIT IS REQUIRED FOR ALL WORKACTIVITIES WITHIN THE PUBLIC RIGHT-OF-WAY. 5. PROVIDE APPROVED BACKWATER DRAINAGE VALVE FOR FIXTURESLOCATED BELOW THE ELEVATION OF NEXT UPSTREAM MANHOLE COVER.FIXTURES ABOVE THIS ELEVATION SHALL NOT DISCHARGE THROUGHVALVE. 6. PROVIDE 6" HOUSE STREET NUMBER VISIBLE AND LEGIBLE FROMSTREET. NUMBERS SHALL BE OF NON-COMBUSTIBLE MATERIALS INSPECIAL FIRE PROTECTION AREAS. 7. AN ENCROACHMENT AGREEMENT IS REQUIRED FOR ALL NONSTANDARDIMPROVEMENTS WITHIN THE PUBLIC RIGHT OF WAY. ALLNON-STANDARD IMPROVEMENTS SHALL COMPLY WITH CITY COUNCILPOLICY L-6. 8. ALL STRUCTURES LIMITED TO MAX. +42" WITHIN FRONT SETBACK AND+72" WITHIN SIDE AND REAR SETBACKS MEASURED FROM EXISTINGGRADE, 9. ALL REQUIRED SETBACK DIMENSIONS ARE FROM FACE OF FINISH 10. ALL WORK RELATED TO WASTEWATER IN THE PUBLIC RIGHT-OF-WAYSHALL BE PERFORMED BE A C-42 LICENSED SANITATION SEWERCONTRACTOR OR AN A LICENSED GENERAL ENGINEERING CONTRACTOR 11. ALL PRIVATE IRRIGATION SPRINKLER HEADS SHALL BE INSTALLED ANDPOSITIONED IN A MANNER THAT WILL NOT CAUSE IRRIGATIONOVERSPRAY ONTO THE PUBLIC RIGHT-OF-WAY 12. A WAIVER OR AN APPROVAL (ENCROACHMENT PERMIT ANDENCROACHMENT AGREEMENT) FOR A PRIVATE ENCROACHMENT SHALLBE OBTAINED FOR PARKWAY WALKWAY SURFACING OF LOOSE ROCK,GRAVEL, OR ANY SURFACING OTHER THAN STANDARD OR COLORED/TEXTURED CONCRETE OR FLAT STONE/ BRICK/ PAVERS INSTALLED ATGRADE LOCATED IN THE ABALONE AVENUE RIGHT OF WAY.ENCROACHMENTS INCLUDE, BUT ARE NOT LIMITED TO, FENCES, WALLS,PATIOS, RAISED PLANTERS, LANDSCAPING, ETC., WHICH ENCROACH INEXCESS OF ONE (1)-FOOT INTO THE PUBLIC RIGHT-OF-WAY, OR EXCEEDTHEE (3)-FEET IN HEIGHT, MEASURED FROM THE TOP OF CURBELEVATION/OR FROM SIDEWALK ELEVATION WHERE SIDEWALK EXISTS 13. FENCES, HEDGES, WALLS, RETAINING WALLS, GUARDRAILS, ANDHANDRAILS OR ANY COMBINATION THEREOF SHALL NOT EXCEED 42 INCHES FROM EXISTING GRADE BEFORE CONSTRUCTION WITHIN THE REQUIRED FRONT SETBACK AREA(S) 14. NO ENCROACHMENTS PERMITTED WITHIN THE ALLEY RIGHT OF WAY INCLUDING FOUNDATION. ASSESSORS PARCEL#: 047 202 27 Sca l e : JR WALZ23 CORPORATE PLAZA, SUITE 150NEWPORT BEACH, CA 92660949.836.5977JR@WALZARCHITECTURE.COM WALZ : ARCHITECTURE Cli e n t : Pro j e c t : Leg a l D e s c r i p t i o n : Dat e : THIS DRAWING IS THE PROPERTY OF JR WALZ,AND IS NOT TO BE REPRODUCED OR COPIED INWHOLE OR IN PART WITHOUT PERMISSION. ITIS NOT TO BE USED ON ANY OTHER PROJECTAND IS TO BE RETURNED ON REQUEST. BY Co r r e c t i o n s / C h a n g e s : # REVISIONSDATE Sea l / S i g n a t u r e : PLAN CHECK Is s u e d F o r : Dra w i n g N o : Con s u l t a n t s : No t e : Dra w i n g : 2025.09.08KORI & TOBY O'BRIEN O'BRIEN.OCEANFRONT 1624 WEST OCEAN FRONT, NEWPORT BEACH SITE LEGEND: · PROPOSED FOOTPRINT AT FLOOR 1 · FRONT DOOR ENTRY · PROPERTY LINE · FOOTPRINT OF OVERHANG · HOSE BIB · OPEN SPACE, SEE A0.1a O' B R I E N . O C E A N F R O N T CITY OF NB NOTES 1. ISSUANCE OF A BUILDING PERMIT BY THE CITY OF NEWPORT BEACHDOES NOT RELIEVE APPLICANTS OF THE LEGAL REQUIREMENTS TOOBSERVE COVENANTS, CONDITIONS AND RESTRICTIONS WHICH MAY BERECORDED AGAINST THE PROPERTY OR TO OBTAIN PLANS. YOU SHOULDCONTACT YOUR COMMUNITY ASSOCIATIONS PRIOR TO COMMENCEMENTOF ANY CONSTRUCTION AUTHORIZED BY THIS PERMIT.2. PRIOR TO PERFORMING ANY WORK IN THE CITY RIGHT-OF-WAY ANENCROACHMENT PERMIT MUST BE OBTAINED FROM THE PUBLIC WORKSDEPARTMENT 3. BARBECUES, FIRE FEATURES, FOUNTAINS, POOLS, SPAS, WALLS,FENCES, PATIO COVERS, AND OTHER FREESTANDING ACCESSORYSTRUCTURES REQUIRE SEPARATE REVIEWS AND PERMITS ANDSEPARATE ELECTRICAL & PLUMBING PERMITS4. A CAL-OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER THAN 5'AND FOR SHORING AND UNDERPINNING. 5. THE MAX. TIME TO COMPLETE CONSTRUCTION ON A PROJECT IS LIMITEDTO (3) YEARS FROM THE DATE OF PERMIT (NBMC 15.02.095) 6. PROVIDE A PROJECT INFORMATION SIGN FOR PROJECTS REQUIRINGFENCING (NEW STRUCTURE OR ADDITION AND REMODEL TO AN EXISTINGSTRUCTURE WITH A COMBINED FLOOR AREA EXCEEDING SEVENTY-FIVE(75) PERCENT OF THE FLOOR AREA OF THE PROPOSED STRUCTURE) INDESIGNATED “HIGH DENSITY AREAS”. PROJECT SIGN SHALL COMPLYWITH NBMC SECTION 15.60.030. DEFERRED SUBMITTALS DEFERRED SUBMITTALS TO BE REVIEWED BY PROJECT ARCHITECT ORENGINEER OF RECORD AND CERTIFIED PRIOR TO SUBMITTAL FOR PLANCHECK OR APPROVAL BY THE CITY 1. A/C CONDENSER LOCATION 2. FIRE SPRINKLERS (OBTAIN FIRE SPRINKLER PERMIT PRIOR TO CALLINGFOR ROOF SHEATHING INSPECTION) HB FRONT PL SETBACK NOTE: SETBACKS ARE MEASURED T0FACE OF EXTERIOR FINISH± PROPERTY LINE GOVERNING BUILDING CODES 2022 CALIFORNIA RESIDENTIAL CODE2022 CALIFORNIA BUILDING CODE2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALGREEN WITH 2017 AMENDMENTS2022 CALIFORNIA ENERGY CODE PROPERTY LINE PRO P E R T Y L I N E 3'-0 " 23 ' - 8 " 3'-212"10'-6"2'-512"6'-0"52'-1" 16'-0"12'-3"74'-3" 19 ' - 0 " C L R . G A R A G E 19'-8" CLR. GARAGE 24' - 0 " 3'-0 " 3'-0 " 9'-912"4'-0"60'-512"13'-9" 12'-3"74'-3"15'-6" ENTRY A CARPORT/OPEN SPACERE: A.01a TRASH/GAS METERS ENCLOSURE ENTRY B LINE OF BALCONY ABV. LINE OF OVERHANG ABOVE LINE OF FLOOR ABOVE MAIN HOUSE ADU GLAZING NUMBER WORK POINT ELEVATION CONTROL INTERIOR ELEVATION NORTH ARROW CENTER LINE PROPERTY LINE HIDDEN/CONCEALED LINE SPOT ELEVATION DIMENSIONS GRIDLINES ELEVATION BUILDING SECTION DETAIL/WALL SECTIION DETAIL ENLARGEMENT DOOR NUMBER NEW CONSTRUCTION 1 HOUR CONSTRUCTION DRAWING SYMBOLS ABBREVIATIONSA@ atabv. aboveAFF Above Finish FloorA.D. Area Drainavg. AverageBBd. BoardBlw. BelowBldg. BuildingBm. BeamBTU British Thermal UnitCCFM Cubic Feet per MinuteCIP Cast in placeCMU Concrete masonry UnitConc. ConcreteCont. ContinuousDDn DownDWV Drain/Waste VentEElasto. Elastomeric(E) ExistingFFAU Forced Air UnitFF Finish FloorFIN FinishFJ Floor JoistFG Finish GradeFO Face of_FOP Face of PlywoodFOS Face of StudFOF Face of FramingGGa. GuageGalv. Galvanizedgyp. GypsumGSM Galv. Sheet Mtl.GWB Gypsum WallboardHHVAC Heating, Ventilation and AirConditioning UnitIInv. InvertJ KLLPG Liquified Petroleum GasMMfg. Manufactur(er)Mtl. MetalMin. MinimumNnic Not In Contract(N) NewOo/ OverOD Outside DiameterODU Out Door UnitOSB Oriented Strand BoardPPtd. PaintedPV Plumbing VentPW PlywoodRReq. RequiredRJ Roof JoistRR Roof RafterRm RoomSS.D. Storm DrainSF Square FeetSC ScupperStl. SteelSS Stainless SteelTTO Top of_TOFF Top of Finish FloorTOR Top of RoofTyp. TypicalT.G. Top of GrateTPS Top of Plywood SheathingUUL Underwriters LabratoriesUNO Unless Noted OtherwiseVWWd. Woodw/ WithWH Water HeaterX 4 2 3 1 1. MASONRY OR CONCRETE FENCES OVER 3.5' ABOVE GRADE, OR WITHIN 3' OFTHE PROPERTY LINE2. SITE RETAINING WALLS WITHIN 3' OF PROPERTY LINE REGARDLESS OF HEIGHT3. ELECTRICAL AND PLUMBING FOR EXTERIOR IMPROVEMENTS DETACHED FROMTHE HOUSE (I.E. BARBEQUE, FOUNTAIN, FIRE FEATURE) SEPARATE SUBMITTALS SCOPE OF WORK AREA CALCS: TWO CARGARAGE 1624 WEST OCEAN FRONT3-STORY SINGLE-FAMILY DWELLING & ADU T.O SLAB: 12.17' LINE OF BUILDING FOOTPRINT N LIST OF DRAWINGS ALLOWABLE HEIGHT CALCULATION:12.81-9.89/92.10 = 3.17%GRADE ESTABLISHMENT FOR < 5%: FIRST FLOOR:LIVING AREA : 1205LIVING AREA ADU: 79GARAGE: 485TOTAL FLOOR 1: 1,769 SECOND FLOOR:LIVING AREA: 1091LIVING AREA ADU: 849TOTAL FLOOR 2: 1,940 TOTAL FLOOR 3: 442TOTAL MAIN HOUSE AREA: 2,738 TOTAL ADU AREA: 928TOTAL LIVING AREA(WITH GARAGE): 3,223 COVERED DECK: 259OPEN SPACE (CARPORT): 372 BUILDABLE AREA :(93.5 x 24) = 2244MAX FLOOR AREA :2244 x 2=4,488THIRD FLOOR BUILDABLE AREA: 20% x 2244=448.8COVERED DECK AND FLOOR 3 AREA: 50% x 2244=1122OPEN SPACE:15% x 2244=336.6 OWNER: DESIGN PROFESSIONAL INRESPONSIBLE CHARGE:JR WALZ510 LARKSPUR AVE,CORONA DEL MAR, CA 92625949.836.5977, WALZ.JR@GMAIL.COM KORI & TOBY O'BRIEN1624 WEST OCEAN FRONT, NEWPORT BEACH,CA 92663415.902.7293,THOMAS.J.OBRIENIII@GMAIL.COM CONTACTS ENERGY CALCULATIONS: MARK MADISON - ENERGY CODE WORKS2600 MICHELSON DR., STE, 1700 IRVINE, CA 92612800.700.0131, MARK@ENERGYCODE.COM STRUCTURAL ENGINEER: PROJECT ADDRESS: 1624 WEST OCEAN FRONT LEGAL DESCRIPTION:APN: 423 246 01PROJECT DESCRIPTION: OCCUPANCY: GROUP R-3/U NUMBER OF STORIES:3 CONSTRUCTION: TYPE V-B/ FIRE SPRINKLERSPER NFPA 13D ZONING DISTRICT: R-1 SINGLE-UNIT RESIDENTIAL PARKING: 2 COVERED, 2 UNCOVERED FARHAD MANSHADI - ESI/FME, INC.1800 E 16TH ST B, SANTA ANA, CA 92701714.835.2800 GEOTECHNICAL ENGINEER: RMCCARTHY CONSULTING, INC.23 CORPORATE PLAZA, SUITE 150NEWPORT BEACH, CA 92660949.629.2539INFO@RMCCARTHYCONSULTING.COM CIVIL ENGINEER: NEW THREE-STORY SINGLEFAMILY RESIDENCE WITH AN ATTACHED ADU AND TWO CARGARAGE. INCLUDES A ROOF DECK, BALCONY, AS WELL ASFIVE BEDROOMS AND SIX AND ONE HALF BATHS. SPECIAL HAZARDS: LIQUEFACTION ADAM TOAL- TOAL ENGINEERING139 AVE. NAVARRO, SAN CLEMENTE, 92672949.492.8586ATOAL@TOALENGINEERING.COM LANDSCAPEARCHITECT :PERDIAN INTERNATIONAL, INC28TH STREET MARINA2600 NEWPORT BLVD., SUITE 130NEWPORT BEACH, CA 92663(949) 675 2445TPRICE@PERIDIAN.NET 2'-0 " (E)WATER METER LOCATION TO REMAIN 10'-0" INSTALL A NEW SEWER CLEAN OUT ON THEEXISTING SEWER LATERAL PERCITY STANDARD 406.MUST BE LOCATED IN THEPUBLIC ROW RE: CIVIL COVERED PATIO OUTLINE OF NEIGHBOR HOME DS 12'-812" (E)PROPERTY LINE FENCE TO BE REPLACE W/BLOCK WALL,MAX 6’-0” ABV. (E)GRADE. SEPARATE PERMIT REQUIREDREF: LANDSCAPE ℄AL L E Y 1'- 9 " 20' - 5 12" 1'-9 " IN FRONT SETBACK PROPERTY LINE WALLSHALL BE MAX.42'' ABV. (E)GRADE POINT #1(10.23FS) POINT#3(12.81 FS) POINT #4(12.89FS) POINT #2(9.89FS) 1'-9" · DOWNSPOUTDS DS 3'-0"MAX.3'-3"6'-0" DS DS DS DS 15'-6" ℄AL L E Y OC E A N F R O N T W E S T TOTAL GROSS FLOOR AREA(GARAGE INCLUDED): 4,151 6" 30' - 0 " 102'-0" SUM( 10.23, 9.89, 12.81, 12.89) / 4= 11.46’ AVG. 93'-212" SLOPE OF THE LOT : HIGH POINT := 12.81LOW POINT := 9.89SLOPE = 3.17% REMOVE EXISTING WALL, INSTALLSIDEWALK TO MATCH THE EXISTINGOCEAN FRONT WALKWAY. UNCOVERED DECK: 499 PUBLIC TRANSIT PARKING FOR ADU NOT REQUIRED PER NBMC 21.48.200.F.(8)(D)(II).PROPERTY IS WITHIN 0.5 MILE WALKING DISTANCE OF PUBLICTRANSIT (SEE ATTACHED GOOGLE WALKING ROUTE). 3'-0 " UNOBSTRUCTED PATH FROM THEFRONT TO THE REAR OF THEPROPERTY AT A MINIMUMOF 36IN. FOR EMERGENCY ACCESS. NEW BLOCK WALL ATPROPERTY LINE PER LANDSCAPE 102'-5" 6" FIRE PIT PER LANDSCAPE PROPERTY LINE GATE PER LANDSCAPE CIVILSURVEY TOPOGRAPHIC SURVEYC-1 TITLE SHEETC-2 PRECISE GRADING & DRAINAGE PLANC-3 DETAILSC-4 CONSTRUCTION POLLUTION PREVENTION PLANC-5 GEOTECHNICAL RECOMMENDATIONSC-6 GEOTECHNICAL RECOMMENDATIONS 2C-7 GEOTECHNICAL RECOMMENDATIONS 3LANDSCAPEL-1 LANDSCAPE DESIGN PLAN VIEWL-2 LANDSCAPE DESIGN ELEVATION ENERGYT24-A-E ENERGY COMPLIANCE STRUCTURALSGN GENERAL NOTESSGN 2 GENERAL NOTESSGN 3 GENERAL NOTESS1 FOUNDATIONS2FLOOR FRAMING PLANFD1 FOUNDATION DETAILSSD1-3 STRUCTURAL DETAILSWSWH1-2 DETAILSWSWH2-5 FRAMING DETAILS ARCHITECTURALA_0.1A_0.1aA_0.2-3aA_1.0-3A_2.0-1A_3.0-2A_4.0-5A_5.0-2A_6.0 SITE & ROOF PLAN / PROJECT INFOAREA CALCS & SLOPE EXHIBITNOTES+APPROVED MOD REQUESTFLOOR+ROOF PLANSEXT. ELEVATIONSSECTIONSDETAILSELECTRICAL AND RCPDOOR & WINDOW SCHEDULE 20 MUNICIPAL NOTES NTS A_0.3aASSESSORS PARCEL#: 047 202 27 Sca l e : JR WALZ23 CORPORATE PLAZA, SUITE 150NEWPORT BEACH, CA 92660949.836.5977JR@WALZARCHITECTURE.COM WALZ : ARCHITECTURE Clie n t : Pro j e c t : Le g a l D e s c r i p t i o n : Dat e : THIS DRAWING IS THE PROPERTY OF JR WALZ,AND IS NOT TO BE REPRODUCED OR COPIED INWHOLE OR IN PART WITHOUT PERMISSION. ITIS NOT TO BE USED ON ANY OTHER PROJECTAND IS TO BE RETURNED ON REQUEST. BY Cor r e c t i o n s / C h a n g e s : # REVISIONSDATE Se a l / S i g n a t u r e : COASTAL DEVELOPMENT PERMIT (RECHEK#1) Is s u e d F o r : Dra w i n g N o : Co n s u l t a n t s : No t e : Dra w i n g : 2025.08.24KORI & TOBY O'BRIEN O'BRIEN.OCEANFRONT 1624 WEST OCEAN FRONT, NEWPORT BEACH 21 (N 7 9 ° 1 9 ' 3 3 " W 3 0 . 0 0 ' ) (N 10°40'27" E 102.50') (N 10°40'27" E 102.50') (9.91FS) (10.27FS) (12. 0 9 F S ) (10.77FS)(11.78FS) (11 . 1 7 F S ) (11.56FS)(11.86FS) (10. 0 8 F S ) (10.59GF) (31.81)TOR (39.36)TOR (3 6 . 0 4 ) TO R (14.57TW)(13 . 8 4 F S ) (11.46FS) (13.26FS) (13.26TW) (10.75FS) WM(10.1 8 F S ) (10. 3 3 F S ) (10 . 4 3 F S ) LOT 12 LO T 1 3 2 STORYBUILDING 2 S T O R Y BU I L D I N G 2SB GAR A G E GMGM 2ND STORYBUILDING LINE (12.05FF)(11.08FS) (10.93FS) (14 . 1 4 F F ) (14.1FS) DEC K LIN E PAL M (22.79)DECK (37.61)RIDGE (37.69)TOP OF RAILING (14.02FF) (34.80)DECK (12.73F S ) (S ) (1 3 . 9 2 F S ) (13.87FS) (13.70FS)(11.89FS)(11.65FS)(11. 3 6 F S ) (10. 9 0 F S ) (10.57FS) (11. 3 5 F S ) (13.26FS)(13. 5 5 F S ) (11.54FS)(12.61FS) DEC K LIN E (10.46FS) (10. 0 0 F S ) X X X X X X PL A S T I C FE N C E XX X X X X XXXX X 2.1 3.2 3.0 2.7 3.0 3.1 4.9 10 0.7 9.5 8.8 9.7 PRO P E R T Y LIN E PRO P E R T Y LIN E PRO P E R T Y LIN E PR O P E R T Y LIN E SE A R C H E D , FO U N D N O T H I N G , FO U N D N O T H I N G DIRT DIRT (9.8 9 F S ) (10 . 6 5 F S ) (10.36FS ) (12.7 8 T W ) (13.32 T W ) (11.82FS) (14.63TW) (12.14FS) (1 3 . 9 0 F S ) (14 . 0 5 F S ) (11.67FS) (11 . 0 9 F S ) (11. 0 F S ) POINT 3 :12.81FS POINT 2 :9.89 FS POINT 1:10.23FS) HIGH POINT POINT 4 :12.89FS HIGH POINT ASSESSORS PARCEL#: 047 202 27 Sca l e : JR WALZ23 CORPORATE PLAZA, SUITE 150NEWPORT BEACH, CA 92660949.836.5977JR@WALZARCHITECTURE.COM WALZ : ARCHITECTURE Clie n t : Pro j e c t : Le g a l D e s c r i p t i o n : Dat e : THIS DRAWING IS THE PROPERTY OF JR WALZ,AND IS NOT TO BE REPRODUCED OR COPIED INWHOLE OR IN PART WITHOUT PERMISSION. ITIS NOT TO BE USED ON ANY OTHER PROJECTAND IS TO BE RETURNED ON REQUEST. BY Cor r e c t i o n s / C h a n g e s : # REVISIONSDATE Se a l / S i g n a t u r e : COASTAL DEVELOPMENT PERMIT (RECHEK#1) Is s u e d F o r : Dra w i n g N o : Co n s u l t a n t s : No t e : Dra w i n g : 2025.08.24KORI & TOBY O'BRIEN O'BRIEN.OCEANFRONT 1624 WEST OCEAN FRONT, NEWPORT BEACH FLOOR AREA EXHIBIT 1/8"=1'-0"A_0.1a 10 9 8 11 7654 1 2 PROPOSED GARAGE:= 422= = 485 PROPOSED FLOOR 1:= 646= 143= 22= 383= 4= 7= 1,205 PROPOSED ADU:= 407 = 298 62= 849 PROPOSED FLOOR 2: = 35= 59= 55= 185= 757= 1,091 PROPOSED FLOOR 3:= 133= 82 178= 442 = 4,151 TOTAL PROPOSED SQUARE FOOTAGE( GARAGE INCLUDED) PROPOSED COVERED DECK:= 259 PROPOSED UNCOVERED DECK:= 17= 390= 75= 17= 499 SLOPE ESTABLISHMENT:HIGHEST GRADE POINT: 12.81'LOWEST GRADE POINT: 9.89POINT DISTANCE: 92.10’SLOPE: 2.92/92.10 = 3.17% ALLOWABLE HEIGHT CALCULATION:GRADE ESTABLISHMENT FOR < 5%:SUM( 10.23, 9.89, 12.81, 12.89) / 4= 11.46’ AVG. 12 SQUARE FOOTAGE CALCULATION PROPOSED FLOOR 1 PROPOSED FLOOR 2 1213 14 161718 PROPOSED FLOOR 3 25 262728 4 1 2 3 4 567 8 9 1018 12 15 14 11 22 19 20 24 23 2527 29 17 28 63 ADU STAIR:= = 79379 = 22= 6 26 3 EST. GRADE EXHIBIT 92'-10" POINT #1: 10.23 FSPOINT #2: 9.89 FSPOINT #3: 12.81 FSPOINT #4: 12.89 FS OPEN SPACE:= 372= 372A ADISTANCE BETW E N H I G H P O I N T & L O W P O I N T LEGEND SUPPLEMENT: ·ADU · MAIN RESIDENCE FLOOR AREA LEGEND SUPPLEMENT: ·ADU OPEN SPACE STAIRS LEGEND SUPPLEMENT: · UNCOVERED PATIO · COVERED PATIO ELEVELEV STAIRS 15'-6"20'-10"9'-7"21'-7"6'-0"16'-2" 23'- 8 " 4" 16'-2"37'-3"20'-10"15'-6" 24 ' - 0 " 17'- 4 " 6'-8 " 20' - 2 " 3'-1 0 " 23' - 4 " 32'-5"10'-9"10'-5"3'-7"12'-8"17'-3" 32'-5"5'-3"19'-6"15'-2"17'-3" 23'- 8 " 17 ' - 2 " 5'-7 " 19' - 7 " 4'-1 " 3'-5" 21'- 1 1 " 3'-5"8'-10"9'-8" 18'-6"13'-3" 20'- 0 " 12'-11"11'-7"1'-6"6'-8" 6'-8"10'-5"5'-4"5'-11" 20'- 1 " 1'-3 " 15'- 5 " 7'- 9 " 3'-1 0 " 4'-0 " 3'-8 " 1'-0 " 21'- 1 " · MAIN RESIDENCE FLOOR AREA · MAIN RESIDENCE FLOOR AREA = 72= 13 16 17 ' - 2 " 15 1920 23 2122 = 29 10'-9" 6'-6" OPENTO SKY MECH. 5'-9"3'-3" 21 24= 21 10.a 2'-6" 10.a= 10 1'-1 1 " OPEN TO SKY TRASH/METER 22 UP PLANS 1/4"=1'-0"A_1.0 FLOOR 1 1 AGING-IN PLACE BATHROOM 110BATHROOM PROVIDED WITH AGING-IN-PLACE AND FALLPREVENTION, REINFORCEMENT FOR GRAB BARS.ELECTRICAL RECEPTACLE OUTLETS, SWITCHES ANDCONTROLS SHALL BE LOCATED NO MORE THAN 48”MEASURED FROM THE TOP OF THE OUTLET BOX AND NOTLESS THAN 15” MEASURED FROM THE BOTTOM OFTHE OUTLET BOX ABOVE THE FINISH FLOOR. CRC R327.1.2. 1'-4"4'-9"4'-11" BAR 102 101A 2A2.0 1A2.0 3A2.1 4A2.1 FIRE MAIN HOUSE WINE ENTRY B MAIL UP DINING 101 LIVING 103 KITCHEN 104 PANTRY / COFFEE 105 PWDR 108 HALLWAY 107 GUEST SUITE - 1 110 CL. 109 111BATH 110 CL 113 W & D 116 GARAGE 115 UTILITY 117 TRASH / METERS 119STAIR B 118 SAND/SURF 114 STAIR 112 ELEV 106 CARPORT / OPEN SPACE 120 B1 C1 104A 105A 101B 106A 108A 110A 110C 114A 113A 116A 115A 115B 117A 119A1'-0 " 4'- 4 34" 14' - 1 0 12" 4'- 4 34" 3'-0 " 2'-0 " 23 ' - 8 " 4" 12'-3"6'-3"6'-6"18'-4"10'-9"10'-0"20'-1012"3'-9"9'-6"2'-3"6" 6'-3" 74'-3"16'-0"12'-3" 3'- 0 " 3'-4 " 3'- 0 " 1'-9 " 1'-9 " 2'- 0 " 16' - 4 " 5" 1'-9 " 3'-0 " 15'-6" 6"1'-9"13'-9"20'-512"10'-5"5'-11"4'-10"10'-512"6'-0"14'-8"6'-3"6'-0" 52'-1"22'-2"12'-3"16'-0" 12'-3" SETBACK 3'-0 " S E T B A C K 3'-0 " S E T B A C K PR O P E R T Y L I N E 31 8 8 8 6'-0" SETBACK 31 31 21 20 9 9 6 7 11 137109 11 6 2 14 9 1 26 1625 2 1491 34 33 9 10 28 3 8 15 1'-6"VIF W/DOORSPECS. PROPERTY LINE PROPERTY LINE 3'-0 " C L R . ADU 1'-614"VIF 19'-8" CLEAR 19' - 0 " C L E A R 18 4 4 2 43 SLOPE PER GRADING PLAN 6'-812"2'-9"2'-5"3'-2"4'-5" D1 D3 E1 E2 6'-11"6'-11" A1 A2 A3 4'-10" 8 4 4 4 4 8 ℄ OF R O O M 3'- 6 " 1'-6 12" 11'- 7 " 3'-4"6'-8"3'-2"4'-11"2'-3" 3'- 2 " 5'-1 " 5'-9 14" 3'- 0 " 3'- 7 12" ENTRY A 11' - 2 12" 2'-5 " 3'-9 " 4A_3.1 4A_3.1 5A_3.1 5A_3.1 6A_3.2 6A_3.2 7A_3.2 7A_3.2 1A_3.01A_3.0 3A_3.11A_3.1 2A_3.02A_3.0 24 ' - 0 " 20'- 6 " PR O P E R T Y L I N E ASSESSORS PARCEL#: 047 202 27 Sca l e : JR WALZ23 CORPORATE PLAZA, SUITE 150NEWPORT BEACH, CA 92660949.836.5977JR@WALZARCHITECTURE.COM WALZ : ARCHITECTURE Clie n t : Pro j e c t : Le g a l D e s c r i p t i o n : Dat e : THIS DRAWING IS THE PROPERTY OF JR WALZ,AND IS NOT TO BE REPRODUCED OR COPIED INWHOLE OR IN PART WITHOUT PERMISSION. ITIS NOT TO BE USED ON ANY OTHER PROJECTAND IS TO BE RETURNED ON REQUEST. BY Cor r e c t i o n s / C h a n g e s : # REVISIONSDATE Se a l / S i g n a t u r e : COASTAL DEVELOPMENT PERMIT (RECHEK#1) Is s u e d F o r : Dra w i n g N o : Co n s u l t a n t s : No t e : Dra w i n g : 2025.08.26KORI & TOBY O'BRIEN O'BRIEN.OCEANFRONT 1624 WEST OCEAN FRONT, NEWPORT BEACH A LEGEND (RE: STRUCTURAL PLANS FRAMING DESIGN & PLANS) GENERAL NOTES· ALL DIMENSIONS ARE TO BE TO THE FACE OF PLYWD, FRAMING,SLAB EDGE OR CENTERLINE OF THE PARTITION U.N.O.· G.C. TO LAYOUT (IN PAINT) THE LOCATIONS OF ALL PARTITIONS,DOORS, LIGHTING, CEILING ELEMENTS, SPRINKLERS, SWITCHES,DIMMERS, THERMOSTATS, POWER & COMM. OUTLETS,MILLWORK AND FURNITURE FOR APPROVAL BY THE OWNERPRIOR TO CONSTRUCTION.· IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO BRING TOTHE ATTENTION OF THE ARCHITECT ANY FIELD CONDITIONS THATDO NOT ALLOW CONSTRUCTION OR INSTALLATION AS DRAWN.· DO NOT SCALE DRAWINGS. DIMENSIONS AS INDICATED TAKEPRECEDENT OVER DRAWINGS.· PROVIDE CONTINUOUS METAL BACKING FOR REINFORCING OFWALLS TO HANG MILLWORK, FURNITURE SHELVING ORCABINETRY.· PROVIDE MILLWORK SHOP DRAWINGS FOR ARCHITECT'SAPPROVAL. MILLWORK TO COMPLY WITH THERECOMMENDATIONS OF THE WOODWORK INSTITUTE OFCALIFORNIA (WIC).· G.C. TO PROVIDE FULL-TIME SUPERINTENDENT'S SUPERVISIONON THE PROJECT. UNLESS OTHERWISE AGREED TO WITH THEOWNER.· AT BATHROOM ACCESSORIES, SUCH AS GRAB BARS, TOWELBARS, SOAP DISHES, ETC. ON OR WITHIN WALLS SHALL BESEALED AGAINST MOISTURE. PROVIDE BACKING AS REQUIRED.· AVOID CUT TILES AND BRICK. LAYOUT TO CONSIDER FINALREQUIREMENT, ADJUST AS NECESSARY. NOTIFY ARCHITECT OFCHANGES. PLAN KEY NOTES (ALL FIXTURE & FINISH SPECS PER INTERIORS) 1 WATERCLOSET - 1.28 GALLON/FLUSH. PROVIDE 24" CLR. INFRONT AND 30" CLR. WIDTH CONCEAL WATER SUPPLY 2 3 5 6 7 9 CLOSET MILLWORK 10 12 13 14 16 15 LANDING: MAX. 1.5" BELOW THRESHOLD. WHERE DOOR DOESNOT SWING OVER LANDING MAX. 7.75" BELOW THRESHOLD.MIN 36" IN DIRECTION OF TRAVEL (R311.3) FULL HEIGHT CABINETS / SHELVES, TYP. SINGLE DEEP BOWL UNDER COUNTER KITCHEN SINK WITHWASTE DISPOSAL AND FAUCET WITH PULL OUT SPRAYERMAX. 1.8 GPM @ 80 PSI, PER SPECS RANGE WITH 180CFM HOOD VENT (SEE NOTES A5.0) 7INCHFOR RIGID OR FLEXIBLE DUCTCOUNTER DEPTH BUILT-IN REFRIGERATOR / FREEZER UPPER CABINETS/SHELVESCOUNTERTOP @ 36" TYP. STAIRWAY & GUARD/HANDRAIL PER 49&50/A4.311 8 PULL OUT TRASH DRAWER, PROVIDE TWO BINS 4 DEEP BOWL UNDERCOUNTER UTILITY SINK AND FAUCET WITHPULL OUT SPRAYER. CUSTOM MILLWORK PER INT.STAINLESS STEEL SHOWER DRAIN SHOWER OR TUB W/ ANTI-SCALDING FIXTURES MAX. 2.0 GPM@ 80 PSI. PROVIDE 12"Ø CLEANOUT. WALL COVERING OFSHOWER SHALL BE TILE, OR APPROVED EQUAL, TO A HEIGHTOF MIN. 72" ABV. DRAIN INLET. FLOAT TILE OVER CEMENTPLASTER BACKING. NET AREA OF SHOWER ENCLOSURE SHALLNOT BE LESS THAN 7.1 SQ. FT. OF FLOOR AREA W/ A MIN. 30"ØCIRCLE. 17 LAVATORY PER INTERIORS, 1.5 GPM @ 60 PSI 18 CEILING ABOVE PER A_5.0-2 19 TANKLESS WATER HEATER PER T24. PROVIDE A 120V ELEC.OUTLET W/IN 3'; A CATEGORY III OR IV VENT, OR A TYPE BVENT WITH A STRAIGHT PIPE, CONDENSATE DRAIN THAT IS NOMORE THAN 2" ABV. THE FINISH SURFACE BELOW, A GASSUPPLY LINE WITH MIN. 200,000 BTU/HR CAPACITY SYSTEM,MIN. 30"X36" WORKPLACE CLEARANCE IN FRONT. 20 21 RECESSED SHOWER FLOOR 22 23 24 CLEAR TEMPERED GLASS ENCLOSURE & DOOR WINE FRIDGE W/ CUSTOM STL. & GLASS CABINET 24" DISHWASHERS ENERGY STAR QUALIFIED ELECTRIC METER MAIN, MIN. 30"X36" CLEAR IN FRONT, VERIFYWITH SCE X XXXX - NEW DOOR PER SCHEDULE A6.0 - NEW WINDOW PER SCHEDULE A6.0 WASHER & DRYER: WASHER SHALL BE QUALIFIED ENERGYSTAR APPLIANCE WITH MAXIMUM WATER USE FACTOR OF 6GALLONS PER CUBIC FEET OF DRUM CAPACITY. (NBMC15.11.010) CLOTHES DRYER. 4" Ø VENT. USE BLOWER TOVENT THRU ROOF INDICATES EMERGENCY EGRESS W/ MIN. 5.7 SF OPENING (MIN.20" CLEAR WIDTH X 24" CLEAR HEIGHT). RE: A6.0 FORDETAILED REQUIREMENTS. ELECTRICAL SUBPANEL, MAINTAIN 3' CLR. IN FRONT B - 1.5" BRICK ADHERED VENEER O/ CEMENT MORTARBED PER 1/A4.0 C - BRD & BATTEN SIDING 12" O/C SPACING PER 7/A4.0 - 2X6 EXTERIOR WALLS W/ R-21 BATT INSULATION.- 2X4 W/ R-15 @ INTERIOR EXCEPT WHERE REQ'DFOR ROUTING PLUMBING PIPES PROVIDE 2X6CONST. SEE FINISHES BELOW. - RATED WALL PER TYPES BELOWFOR PENETRATION NOTES SEE A_0.2 25 26 27 WAUPACA EXCELEVATOR HYDRAULIC ELEVATOR ANDEQUIPMENT, PROVIDE 12" DEEP PIT PER MFT. SPECS.CONTACT MIKE BURKE (MCKINLEY ELEVATOR): 949-735-0373 28 29 WALL OVEN30FURNACE PER ENERGY CALCS & SUBCONTRACTOR DESIGN 31 EXT. OVERHANG ABOVE 32 - HORIZONTAL LAP SIDING, PTD. WHITE PER 4/A4.0 33 34 BAR SINK ICE MAKER 35 NICHE PER INT. 36 COMBO SHOWER AND TUB REFER TO NOTE 2 37 COFFEE STATION W/ WATER SUPPLY3818" DISH WASHER DRAWER PER INT. SPECS39COOK TOP W/ SPEED OVEN BELOW PER INT. SPECS40 DEFENDER REVERSE OSMOSIS DOMESTIC WATER FILTER41 BUILT-IN INFRARED SAUNA, E2H FROM RADIANT SAUNA.42 U/C APPLIANCES & MILLWORK PER LANDSCAPE43SOLAR BACKUP BATTERY, SEE A_0.2 FOR INSTALL. REQS.44 1 2 3 - INT. 1-HR RATED PER 61/A_4.4 4 - EXT. 1-HR RATED PER 63/A_4.4 - EXT. 1-HR RATED PER 64/A_4.4 (BRICK) - 1-HR & 50 STC RATED DEMISING WALL PER 62/A_4.4 MASON-LITE LINEAR MFP-60 W/ PERMANENT GLASS DOORS &DECORATIVE GAS APPLIANCE INSTALLED, TESTED AND LISTEDPER ESR-2401. PROVIDE LISTED 10"Ø TYPE B GAS VENT &SHROUD. CASSETTE HEAT PUMP IN SOFFIT45 4 LEGEND SUPPLEMENT: ·ADU NOTES COVERED PATIORE:LANDSCAPE 2'-5" D2 2'-9" 16' - 4 " 5'-1 0 " OPEN TO SKY 18'-9"11" 12 UP12''RISER 6' 23 PLANS 1/4"=1'-0"A_1.1 1 FLOOR 2 1 LEGEND SUPPLEMENT: ·ADUZCLASS 'A' THERMORY PINE, RJ8258F-1 TESTED PER ASTME108 O/ MIN. 2% SLOPE: MER-KO CLASS 'A' WATERPROOFELASTOMERIC MEMBRANE PER IAPMO ER-517 Y X ROOF DRAIN PER 13/A4.0DECK DRAIN PER 14/A4.0 V ZINC COATED STANDING SEAM METAL AGED VINTAGEFINISH U ZINC COATED HALF ROUND GUTTER W/ AGED VINTAGEFINISH T CUSTOM FIBERGLASS WATERPROOF PLANTER W/INTEGRAL ATRIUM DRAINS & OVERFLOW ROOF NOTES UNVENTED ASSEMBLIES:1. MIN. 1" AIR IMPERMEABLE SPRAY FOAM INSULATION APPLIEDTO THE UNDERSIDE OF THE ROOF SHEATHING W/ BATTINSULATION BELOW. MIN. R-30 TOTAL. 2. INTERIOR CLASS I VAPOR RETARDERS ARE NOT INSTALLEDON THE CEILING SIDE (ATTIC FLOOR) OF THE UNVENTED ATTICASSEMBLY OR ON THE CEILING SIDE OF THE UNVENTEDENCLOSED ROOF FRAMING ASSEMBLY.3. PROVIDE R-30 FIBERGLASS BATT FLOOR INSULATION4. OBTAIN FIRE SPRINKLER PERMIT PRIOR TO CALLING FORROOF SHEATHING INSPECTION. S OVERFLOW DRAIN AGING-IN PLACE BATHROOM 109 & GUEST SUITE 111BATHROOM PROVIDED WITH AGING-IN-PLACE AND FALLPREVENTION, REINFORCEMENT FOR GRAB BARS.ELECTRICAL RECEPTACLE OUTLETS, SWITCHES ANDCONTROLS SHALL BE LOCATED NO MORE THAN 48”MEASURED FROM THE TOP OF THE OUTLET BOX AND NOTLESS THAN 15” MEASURED FROM THE BOTTOM OFTHE OUTLET BOX ABOVE THE FINISH FLOOR. CRC R327.1.2. 4'- 7 12" 3'- 7 " 3'-9 " 3'-5 " 3'-7 " 4'-7 12" 4'-3"2'-4"3'-1"1'-612"1'-8"3'-11"3'-11"3'-11"17'-11"1'-912"1'-912" ℄ O F R O O M 2'-0"3'-2"5'-2"5'-2" ℄ O F R O O M 2'-712"2'-912"2'-1012"1'-8"2'-8"1'-8"2'-412"1'-312"4'-2"3'-8"2'-5"2'-5"1'-812"1'-912"4'-112"1'-6" LINEN MECH VANITY CL UPDN DN 2A2.0 1A2.0 3A2.1 4A2.1 MASTER SUITE 201 OFFICE 202 BALCONY 203 BATH 204 CLOSET 205 ELEV 206 LAUNDRY 207 GUEST SUITE - 2 208 CL 209 BATH 210 BATH 211 BUNK 212 SUITE - B 213 CL 214 BATH 215 KITCHEN 216 FAMILY / BONUS 217 F1 F2 F3 G1 G2 G3 H1 I1 I2 J1 J2 K1 L2 M1 M2 M3 M5 N2N3N4O1P1P2Q1Q2Q3R1R2 201A 205A 204A 204B 201B 206A201C 207A 208A 209A 210A 211A 211B 212A 213A 213B 215A 215B 14 9 1 2 16 ℄ O F T U B 2 14 149 1 15'-1014"15'-3"10'-9"10'-0"4'-0"32'-412" 89'-7" 1'-4"VIF W/DOORSPECS. 1'-4"VIF 9'-314"7'-734"8'-812"3'-5"3'-5"4'-10"8'-3"6'-2"7'-11"12'-3"5'-10"11'-1012" 89'-7" 4A_3.1 4A_3.1 5A_3.1 5A_3.1 6A_3.2 6A_3.2 7A_3.2 7A_3.2 1A_3.0 3A_3.1 2A_3.0 24' - 0 " 4'-2 34" 14 ' - 1 0 12" 4'-4 34" 23' - 6 " ASSESSORS PARCEL#: 047 202 27 Sca l e : JR WALZ23 CORPORATE PLAZA, SUITE 150NEWPORT BEACH, CA 92660949.836.5977JR@WALZARCHITECTURE.COM WALZ : ARCHITECTURE Clie n t : Pro j e c t : Le g a l D e s c r i p t i o n : Dat e : THIS DRAWING IS THE PROPERTY OF JR WALZ,AND IS NOT TO BE REPRODUCED OR COPIED INWHOLE OR IN PART WITHOUT PERMISSION. ITIS NOT TO BE USED ON ANY OTHER PROJECTAND IS TO BE RETURNED ON REQUEST. BY Cor r e c t i o n s / C h a n g e s : # REVISIONSDATE Se a l / S i g n a t u r e : COASTAL DEVELOPMENT PERMIT (RECHEK#1) Is s u e d F o r : Dra w i n g N o : Co n s u l t a n t s : No t e : Dra w i n g : 2025.08.26KORI & TOBY O'BRIEN O'BRIEN.OCEANFRONT 1624 WEST OCEAN FRONT, NEWPORT BEACH A LEGEND (RE: STRUCTURAL PLANS FRAMING DESIGN & PLANS) GENERAL NOTES· ALL DIMENSIONS ARE TO BE TO THE FACE OF PLYWD, FRAMING,SLAB EDGE OR CENTERLINE OF THE PARTITION U.N.O.· G.C. TO LAYOUT (IN PAINT) THE LOCATIONS OF ALL PARTITIONS,DOORS, LIGHTING, CEILING ELEMENTS, SPRINKLERS, SWITCHES,DIMMERS, THERMOSTATS, POWER & COMM. OUTLETS,MILLWORK AND FURNITURE FOR APPROVAL BY THE OWNERPRIOR TO CONSTRUCTION.· IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO BRING TOTHE ATTENTION OF THE ARCHITECT ANY FIELD CONDITIONS THATDO NOT ALLOW CONSTRUCTION OR INSTALLATION AS DRAWN.· DO NOT SCALE DRAWINGS. DIMENSIONS AS INDICATED TAKEPRECEDENT OVER DRAWINGS.· PROVIDE CONTINUOUS METAL BACKING FOR REINFORCING OFWALLS TO HANG MILLWORK, FURNITURE SHELVING ORCABINETRY.· PROVIDE MILLWORK SHOP DRAWINGS FOR ARCHITECT'SAPPROVAL. MILLWORK TO COMPLY WITH THERECOMMENDATIONS OF THE WOODWORK INSTITUTE OFCALIFORNIA (WIC).· G.C. TO PROVIDE FULL-TIME SUPERINTENDENT'S SUPERVISIONON THE PROJECT. UNLESS OTHERWISE AGREED TO WITH THEOWNER.· AT BATHROOM ACCESSORIES, SUCH AS GRAB BARS, TOWELBARS, SOAP DISHES, ETC. ON OR WITHIN WALLS SHALL BESEALED AGAINST MOISTURE. PROVIDE BACKING AS REQUIRED.· AVOID CUT TILES AND BRICK. LAYOUT TO CONSIDER FINALREQUIREMENT, ADJUST AS NECESSARY. NOTIFY ARCHITECT OFCHANGES. PLAN KEY NOTES (ALL FIXTURE & FINISH SPECS PER INTERIORS) 1 WATERCLOSET - 1.28 GALLON/FLUSH. PROVIDE 24" CLR. INFRONT AND 30" CLR. WIDTH CONCEAL WATER SUPPLY 2 3 5 6 7 9 CLOSET MILLWORK 10 12 13 14 16 15 LANDING: MAX. 1.5" BELOW THRESHOLD. WHERE DOOR DOESNOT SWING OVER LANDING MAX. 7.75" BELOW THRESHOLD.MIN 36" IN DIRECTION OF TRAVEL (R311.3) FULL HEIGHT CABINETS / SHELVES, TYP. SINGLE DEEP BOWL UNDER COUNTER KITCHEN SINK WITHWASTE DISPOSAL AND FAUCET WITH PULL OUT SPRAYERMAX. 1.8 GPM @ 80 PSI, PER SPECS RANGE WITH 180CFM HOOD VENT (SEE NOTES A5.0) 7INCHFOR RIGID OR FLEXIBLE DUCTCOUNTER DEPTH BUILT-IN REFRIGERATOR / FREEZER UPPER CABINETS/SHELVESCOUNTERTOP @ 36" TYP. STAIRWAY & GUARD/HANDRAIL PER 49&50/A4.311 8 PULL OUT TRASH DRAWER, PROVIDE TWO BINS 4 DEEP BOWL UNDERCOUNTER UTILITY SINK AND FAUCET WITHPULL OUT SPRAYER. CUSTOM MILLWORK PER INT. STAINLESS STEEL SHOWER DRAIN SHOWER OR TUB W/ ANTI-SCALDING FIXTURES MAX. 2.0 GPM@ 80 PSI. PROVIDE 12"Ø CLEANOUT. WALL COVERING OFSHOWER SHALL BE TILE, OR APPROVED EQUAL, TO A HEIGHTOF MIN. 72" ABV. DRAIN INLET. FLOAT TILE OVER CEMENTPLASTER BACKING. NET AREA OF SHOWER ENCLOSURE SHALLNOT BE LESS THAN 7.1 SQ. FT. OF FLOOR AREA W/ A MIN. 30"ØCIRCLE. 17 LAVATORY PER INTERIORS, 1.5 GPM @ 60 PSI 18 CEILING ABOVE PER A_5.0-2 19 TANKLESS WATER HEATER PER T24. PROVIDE A 120V ELEC.OUTLET W/IN 3'; A CATEGORY III OR IV VENT, OR A TYPE BVENT WITH A STRAIGHT PIPE, CONDENSATE DRAIN THAT IS NOMORE THAN 2" ABV. THE FINISH SURFACE BELOW, A GASSUPPLY LINE WITH MIN. 200,000 BTU/HR CAPACITY SYSTEM,MIN. 30"X36" WORKPLACE CLEARANCE IN FRONT. 20 21 RECESSED SHOWER FLOOR 22 23 24 CLEAR TEMPERED GLASS ENCLOSURE & DOOR WINE FRIDGE W/ CUSTOM STL. & GLASS CABINET 24" DISHWASHERS ENERGY STAR QUALIFIED ELECTRIC METER MAIN, MIN. 30"X36" CLEAR IN FRONT, VERIFYWITH SCE X XXXX - NEW DOOR PER SCHEDULE A6.0 - NEW WINDOW PER SCHEDULE A6.0 WASHER & DRYER: WASHER SHALL BE QUALIFIED ENERGYSTAR APPLIANCE WITH MAXIMUM WATER USE FACTOR OF 6GALLONS PER CUBIC FEET OF DRUM CAPACITY. (NBMC15.11.010) CLOTHES DRYER. 4" Ø VENT. USE BLOWER TOVENT THRU ROOF INDICATES EMERGENCY EGRESS W/ MIN. 5.7 SF OPENING (MIN.20" CLEAR WIDTH X 24" CLEAR HEIGHT). RE: A6.0 FORDETAILED REQUIREMENTS. ELECTRICAL SUBPANEL, MAINTAIN 3' CLR. IN FRONT B - 1.5" BRICK ADHERED VENEER O/ CEMENT MORTARBED PER 1/A4.0 C - BRD & BATTEN SIDING 12" O/C SPACING PER 7/A4.0 - 2X6 EXTERIOR WALLS W/ R-21 BATT INSULATION.- 2X4 W/ R-15 @ INTERIOR EXCEPT WHERE REQ'DFOR ROUTING PLUMBING PIPES PROVIDE 2X6CONST. SEE FINISHES BELOW. - RATED WALL PER TYPES BELOWFOR PENETRATION NOTES SEE A_0.2 25 26 27 WAUPACA EXCELEVATOR HYDRAULIC ELEVATOR ANDEQUIPMENT, PROVIDE 12" DEEP PIT PER MFT. SPECS.CONTACT MIKE BURKE (MCKINLEY ELEVATOR): 949-735-0373 28 29 WALL OVEN 30 FURNACE PER ENERGY CALCS & SUBCONTRACTOR DESIGN 31 EXT. OVERHANG ABOVE 32 - HORIZONTAL LAP SIDING, PTD. WHITE PER 4/A4.0 33 34 BAR SINK ICE MAKER 35 NICHE PER INT. 36 COMBO SHOWER AND TUB REFER TO NOTE 2 37 COFFEE STATION W/ WATER SUPPLY38 18" DISH WASHER DRAWER PER INT. SPECS39 COOK TOP W/ SPEED OVEN BELOW PER INT. SPECS40DEFENDER REVERSE OSMOSIS DOMESTIC WATER FILTER41BUILT-IN INFRARED SAUNA, E2H FROM RADIANT SAUNA.42 U/C APPLIANCES & MILLWORK PER LANDSCAPE43SOLAR BACKUP BATTERY, SEE A_0.2 FOR INSTALL. REQS.44 1 2 3 - INT. 1-HR RATED PER 61/A_4.4 4 - EXT. 1-HR RATED PER 63/A_4.4 - EXT. 1-HR RATED PER 64/A_4.4 (BRICK) - 1-HR & 50 STC RATED DEMISING WALL PER 62/A_4.4 MASON-LITE LINEAR MFP-60 W/ PERMANENT GLASS DOORS &DECORATIVE GAS APPLIANCE INSTALLED, TESTED AND LISTEDPER ESR-2401. PROVIDE LISTED 10"Ø TYPE B GAS VENT &SHROUD. CASSETTE HEAT PUMP IN SOFFIT45 212B 3'-0 " 3'- 0 " 2 4'-0 " 2'- 0 " 2'- 0 " 2'- 0 " 6" 6'-5"6'-0"6" 6'-5"6'-0" 3'- 0 " NOTES 5'-0" N1 ℄ O F R O O M 2'-5"2'-5" S1 S2 S3 "BALCONYENCROACHMENTPERMITTED PER20.30.110.D.5.(A)(B) L1 M4 R. F.ICE 1'-612" 24 A LEGEND (RE: STRUCTURAL PLANS FRAMING DESIGN & PLANS) GENERAL NOTES· ALL DIMENSIONS ARE TO BE TO THE FACE OF PLYWD, FRAMING,SLAB EDGE OR CENTERLINE OF THE PARTITION U.N.O.· G.C. TO LAYOUT (IN PAINT) THE LOCATIONS OF ALL PARTITIONS,DOORS, LIGHTING, CEILING ELEMENTS, SPRINKLERS, SWITCHES,DIMMERS, THERMOSTATS, POWER & COMM. OUTLETS,MILLWORK AND FURNITURE FOR APPROVAL BY THE OWNERPRIOR TO CONSTRUCTION.· IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO BRING TOTHE ATTENTION OF THE ARCHITECT ANY FIELD CONDITIONS THATDO NOT ALLOW CONSTRUCTION OR INSTALLATION AS DRAWN.· DO NOT SCALE DRAWINGS. DIMENSIONS AS INDICATED TAKEPRECEDENT OVER DRAWINGS.· PROVIDE CONTINUOUS METAL BACKING FOR REINFORCING OFWALLS TO HANG MILLWORK, FURNITURE SHELVING ORCABINETRY.· PROVIDE MILLWORK SHOP DRAWINGS FOR ARCHITECT'SAPPROVAL. MILLWORK TO COMPLY WITH THERECOMMENDATIONS OF THE WOODWORK INSTITUTE OFCALIFORNIA (WIC).· G.C. TO PROVIDE FULL-TIME SUPERINTENDENT'S SUPERVISIONON THE PROJECT. UNLESS OTHERWISE AGREED TO WITH THEOWNER.· AT BATHROOM ACCESSORIES, SUCH AS GRAB BARS, TOWELBARS, SOAP DISHES, ETC. ON OR WITHIN WALLS SHALL BESEALED AGAINST MOISTURE. PROVIDE BACKING AS REQUIRED.· AVOID CUT TILES AND BRICK. LAYOUT TO CONSIDER FINALREQUIREMENT, ADJUST AS NECESSARY. NOTIFY ARCHITECT OFCHANGES. PLAN KEY NOTES (ALL FIXTURE & FINISH SPECS PER INTERIORS) 1 WATERCLOSET - 1.28 GALLON/FLUSH. PROVIDE 24" CLR. INFRONT AND 30" CLR. WIDTH CONCEAL WATER SUPPLY 2 3 5 6 7 9 CLOSET MILLWORK 10 12 13 14 16 15 LANDING: MAX. 1.5" BELOW THRESHOLD. WHERE DOOR DOESNOT SWING OVER LANDING MAX. 7.75" BELOW THRESHOLD.MIN 36" IN DIRECTION OF TRAVEL (R311.3) FULL HEIGHT CABINETS / SHELVES, TYP. SINGLE DEEP BOWL UNDER COUNTER KITCHEN SINK WITHWASTE DISPOSAL AND FAUCET WITH PULL OUT SPRAYERMAX. 1.8 GPM @ 80 PSI, PER SPECS RANGE WITH 180CFM HOOD VENT (SEE NOTES A5.0) 7INCHFOR RIGID OR FLEXIBLE DUCTCOUNTER DEPTH BUILT-IN REFRIGERATOR / FREEZER UPPER CABINETS/SHELVESCOUNTERTOP @ 36" TYP. STAIRWAY & GUARD/HANDRAIL PER 49&50/A4.311 8 PULL OUT TRASH DRAWER, PROVIDE TWO BINS 4 DEEP BOWL UNDERCOUNTER UTILITY SINK AND FAUCET WITHPULL OUT SPRAYER. CUSTOM MILLWORK PER INT. STAINLESS STEEL SHOWER DRAIN SHOWER OR TUB W/ ANTI-SCALDING FIXTURES MAX. 2.0 GPM@ 80 PSI. PROVIDE 12"Ø CLEANOUT. WALL COVERING OFSHOWER SHALL BE TILE, OR APPROVED EQUAL, TO A HEIGHTOF MIN. 72" ABV. DRAIN INLET. FLOAT TILE OVER CEMENTPLASTER BACKING. NET AREA OF SHOWER ENCLOSURE SHALLNOT BE LESS THAN 7.1 SQ. FT. OF FLOOR AREA W/ A MIN. 30"ØCIRCLE. 17 LAVATORY PER INTERIORS, 1.5 GPM @ 60 PSI 18 CEILING ABOVE PER A_5.0-2 19 TANKLESS WATER HEATER PER T24. PROVIDE A 120V ELEC.OUTLET W/IN 3'; A CATEGORY III OR IV VENT, OR A TYPE BVENT WITH A STRAIGHT PIPE, CONDENSATE DRAIN THAT IS NOMORE THAN 2" ABV. THE FINISH SURFACE BELOW, A GASSUPPLY LINE WITH MIN. 200,000 BTU/HR CAPACITY SYSTEM,MIN. 30"X36" WORKPLACE CLEARANCE IN FRONT. 20 21 RECESSED SHOWER FLOOR 22 23 24 CLEAR TEMPERED GLASS ENCLOSURE & DOOR WINE FRIDGE W/ CUSTOM STL. & GLASS CABINET 24" DISHWASHERS ENERGY STAR QUALIFIED ELECTRIC METER MAIN, MIN. 30"X36" CLEAR IN FRONT, VERIFYWITH SCE X XXXX - NEW DOOR PER SCHEDULE A6.0 - NEW WINDOW PER SCHEDULE A6.0 WASHER & DRYER: WASHER SHALL BE QUALIFIED ENERGYSTAR APPLIANCE WITH MAXIMUM WATER USE FACTOR OF 6GALLONS PER CUBIC FEET OF DRUM CAPACITY. (NBMC15.11.010) CLOTHES DRYER. 4" Ø VENT. USE BLOWER TOVENT THRU ROOF INDICATES EMERGENCY EGRESS W/ MIN. 5.7 SF OPENING (MIN.20" CLEAR WIDTH X 24" CLEAR HEIGHT). RE: A6.0 FORDETAILED REQUIREMENTS. ELECTRICAL SUBPANEL, MAINTAIN 3' CLR. IN FRONT B - 1.5" BRICK ADHERED VENEER O/ CEMENT MORTARBED PER 1/A4.0 C - BRD & BATTEN SIDING 12" O/C SPACING PER 7/A4.0 - 2X6 EXTERIOR WALLS W/ R-21 BATT INSULATION.- 2X4 W/ R-15 @ INTERIOR EXCEPT WHERE REQ'DFOR ROUTING PLUMBING PIPES PROVIDE 2X6CONST. SEE FINISHES BELOW. - RATED WALL PER TYPES BELOWFOR PENETRATION NOTES SEE A_0.2 25 26 27 WAUPACA EXCELEVATOR HYDRAULIC ELEVATOR ANDEQUIPMENT, PROVIDE 12" DEEP PIT PER MFT. SPECS.CONTACT MIKE BURKE (MCKINLEY ELEVATOR): 949-735-0373 28 29 WALL OVEN 30 FURNACE PER ENERGY CALCS & SUBCONTRACTOR DESIGN 31 EXT. OVERHANG ABOVE 32 - HORIZONTAL LAP SIDING, PTD. WHITE PER 4/A4.0 33 34 BAR SINK ICE MAKER 35 NICHE PER INT. 36 COMBO SHOWER AND TUB REFER TO NOTE 2 37 COFFEE STATION W/ WATER SUPPLY38 18" DISH WASHER DRAWER PER INT. SPECS39 COOK TOP W/ SPEED OVEN BELOW PER INT. SPECS40DEFENDER REVERSE OSMOSIS DOMESTIC WATER FILTER41BUILT-IN INFRARED SAUNA, E2H FROM RADIANT SAUNA.42 U/C APPLIANCES & MILLWORK PER LANDSCAPE43SOLAR BACKUP BATTERY, SEE A_0.2 FOR INSTALL. REQS.44 1 2 3 - INT. 1-HR RATED PER 61/A_4.4 4 - EXT. 1-HR RATED PER 63/A_4.4 - EXT. 1-HR RATED PER 64/A_4.4 (BRICK) - 1-HR & 50 STC RATED DEMISING WALL PER 62/A_4.4 MASON-LITE LINEAR MFP-60 W/ PERMANENT GLASS DOORS &DECORATIVE GAS APPLIANCE INSTALLED, TESTED AND LISTEDPER ESR-2401. PROVIDE LISTED 10"Ø TYPE B GAS VENT &SHROUD. CASSETTE HEAT PUMP IN SOFFIT45 PLANS 1/4"=1'-0"A_1.2 1FLOOR 3 1 STAIR SAUNA BAR ELEV DN SOLAR UP STEAM FIRE/TV SKYLIGHT 4A_3.1 4A_3.1 5A_3.1 5A_3.1 6A_3.2 6A_3.2 7A_3.2 7A_3.2 1A_3.0 3A_3.1 2A_3.02A2.0 1A2.0 3A2.1 4A2.1 ROOF DECK 301 BONUS 304 BBQ 302 COVERED DECK 303 ELEV 305 CL 306 HALLWAY 307 BATH 308 HVAC309 FURNACEINATIC BELOW 8'- 5 " 6'-6 12" 5'-0 12" 3'-712"1'-9"8'-1"2'-9" 7'-012"4'-912"4'-8" 309A 308B 308A 308C V2 V1 T2 T3 305A 306A 304A 6'-712"3'-012"6'-10"11'-012"5'-4"4'-0"9'-3"4'-0"10'-114"3'-5" 29'-512" 93'-112" 24' - 3 " 2'-1"7'-3"1'-1012"7'-214"1'-434"7'-3"2'-5"5'-1012"5'-212"1'-6"11'-7"10"18'-9"3'-5" 93'-112" 8" 22' - 4 " 6" 23 ' - 6 " Z CLASS 'A' THERMORY PINE, RJ8258F-1 TESTED PER ASTME108 O/ MIN. 2% SLOPE: MER-KO CLASS 'A' WATERPROOFELASTOMERIC MEMBRANE PER IAPMO ER-517 Y X ROOF DRAIN PER 13/A4.0DECK DRAIN PER 14/A4.0 V ZINC COATED STANDING SEAM METAL AGED VINTAGEFINISH U ZINC COATED HALF ROUND GUTTER W/ AGED VINTAGEFINISH T CUSTOM FIBERGLASS WATERPROOF PLANTER W/INTEGRAL ATRIUM DRAINS & OVERFLOW ROOF NOTES UNVENTED ASSEMBLIES:1. MIN. 1" AIR IMPERMEABLE SPRAY FOAM INSULATION APPLIEDTO THE UNDERSIDE OF THE ROOF SHEATHING W/ BATTINSULATION BELOW. MIN. R-30 TOTAL. 2. INTERIOR CLASS I VAPOR RETARDERS ARE NOT INSTALLEDON THE CEILING SIDE (ATTIC FLOOR) OF THE UNVENTED ATTICASSEMBLY OR ON THE CEILING SIDE OF THE UNVENTEDENCLOSED ROOF FRAMING ASSEMBLY.3. PROVIDE R-30 FIBERGLASS BATT FLOOR INSULATION4. OBTAIN FIRE SPRINKLER PERMIT PRIOR TO CALLING FORROOF SHEATHING INSPECTION. S OVERFLOW DRAIN AGING-IN PLACE BATHROOM 109 & GUEST SUITE 111BATHROOM PROVIDED WITH AGING-IN-PLACE AND FALLPREVENTION, REINFORCEMENT FOR GRAB BARS.ELECTRICAL RECEPTACLE OUTLETS, SWITCHES ANDCONTROLS SHALL BE LOCATED NO MORE THAN 48”MEASURED FROM THE TOP OF THE OUTLET BOX AND NOTLESS THAN 15” MEASURED FROM THE BOTTOM OFTHE OUTLET BOX ABOVE THE FINISH FLOOR. CRC R327.1.2. ASSESSORS PARCEL#: 047 202 27 Sca l e : JR WALZ23 CORPORATE PLAZA, SUITE 150NEWPORT BEACH, CA 92660949.836.5977JR@WALZARCHITECTURE.COM WALZ : ARCHITECTURE Clie n t : Pro j e c t : Le g a l D e s c r i p t i o n : Dat e : THIS DRAWING IS THE PROPERTY OF JR WALZ,AND IS NOT TO BE REPRODUCED OR COPIED INWHOLE OR IN PART WITHOUT PERMISSION. ITIS NOT TO BE USED ON ANY OTHER PROJECTAND IS TO BE RETURNED ON REQUEST. BY Cor r e c t i o n s / C h a n g e s : # REVISIONSDATE Se a l / S i g n a t u r e : COASTAL DEVELOPMENT PERMIT (RECHEK#1) Is s u e d F o r : Dra w i n g N o : Co n s u l t a n t s : No t e : Dra w i n g : 2025.08.26KORI & TOBY O'BRIEN O'BRIEN.OCEANFRONT 1624 WEST OCEAN FRONT, NEWPORT BEACH NOTES XXX311 310A VTYP. RE:LANDSCAPE LEGEND SUPPLEMENT: ·ADU 1'- 6 "T1 31'-2" 3'-2 " 2'-0 " 102'-6" 309B 3'-2" 3'-0 " 2'-0 " 2'-0 " 2'-0 ' ' 29'-10" 50' TRAVE L D I S T A N C E TO STAI R W A Y 30' - 0 " 4" 23' - 4 " 3'-2" 25 PLANS 1/4"=1'-0"A_1.3 1ROOF PLAN 1 ROOF DECK SOLAR SKYLIGHT RID G E : 4 0 . 1 2 ' RIDGE 37.38' SKYLIGHT 4A_3.1 4A_3.1 5A_3.1 5A_3.1 6A_3.2 6A_3.2 7A_3.2 7A_3.2 1A_3.0 3A_3.1 2A_3.02A2.0 1A2.0 3A2.1 4A2.1 A LEGEND (RE: STRUCTURAL PLANS FRAMING DESIGN & PLANS) GENERAL NOTES· ALL DIMENSIONS ARE TO BE TO THE FACE OF PLYWD, FRAMING,SLAB EDGE OR CENTERLINE OF THE PARTITION U.N.O.· G.C. TO LAYOUT (IN PAINT) THE LOCATIONS OF ALL PARTITIONS,DOORS, LIGHTING, CEILING ELEMENTS, SPRINKLERS, SWITCHES,DIMMERS, THERMOSTATS, POWER & COMM. OUTLETS,MILLWORK AND FURNITURE FOR APPROVAL BY THE OWNERPRIOR TO CONSTRUCTION.· IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO BRING TOTHE ATTENTION OF THE ARCHITECT ANY FIELD CONDITIONS THATDO NOT ALLOW CONSTRUCTION OR INSTALLATION AS DRAWN.· DO NOT SCALE DRAWINGS. DIMENSIONS AS INDICATED TAKEPRECEDENT OVER DRAWINGS.· PROVIDE CONTINUOUS METAL BACKING FOR REINFORCING OFWALLS TO HANG MILLWORK, FURNITURE SHELVING ORCABINETRY.· PROVIDE MILLWORK SHOP DRAWINGS FOR ARCHITECT'SAPPROVAL. MILLWORK TO COMPLY WITH THERECOMMENDATIONS OF THE WOODWORK INSTITUTE OFCALIFORNIA (WIC).· G.C. TO PROVIDE FULL-TIME SUPERINTENDENT'S SUPERVISIONON THE PROJECT. UNLESS OTHERWISE AGREED TO WITH THEOWNER.· AT BATHROOM ACCESSORIES, SUCH AS GRAB BARS, TOWELBARS, SOAP DISHES, ETC. ON OR WITHIN WALLS SHALL BESEALED AGAINST MOISTURE. PROVIDE BACKING AS REQUIRED.· AVOID CUT TILES AND BRICK. LAYOUT TO CONSIDER FINALREQUIREMENT, ADJUST AS NECESSARY. NOTIFY ARCHITECT OFCHANGES. PLAN KEY NOTES (ALL FIXTURE & FINISH SPECS PER INTERIORS) 1 WATERCLOSET - 1.28 GALLON/FLUSH. PROVIDE 24" CLR. INFRONT AND 30" CLR. WIDTH CONCEAL WATER SUPPLY 2 3 5 6 7 9 CLOSET MILLWORK 10 12 13 14 16 15 LANDING: MAX. 1.5" BELOW THRESHOLD. WHERE DOOR DOESNOT SWING OVER LANDING MAX. 7.75" BELOW THRESHOLD.MIN 36" IN DIRECTION OF TRAVEL (R311.3) FULL HEIGHT CABINETS / SHELVES, TYP. SINGLE DEEP BOWL UNDER COUNTER KITCHEN SINK WITHWASTE DISPOSAL AND FAUCET WITH PULL OUT SPRAYERMAX. 1.8 GPM @ 80 PSI, PER SPECS RANGE WITH 180CFM HOOD VENT (SEE NOTES A5.0) 7INCHFOR RIGID OR FLEXIBLE DUCTCOUNTER DEPTH BUILT-IN REFRIGERATOR / FREEZER UPPER CABINETS/SHELVESCOUNTERTOP @ 36" TYP. STAIRWAY & GUARD/HANDRAIL PER 49&50/A4.311 8 PULL OUT TRASH DRAWER, PROVIDE TWO BINS 4 DEEP BOWL UNDERCOUNTER UTILITY SINK AND FAUCET WITHPULL OUT SPRAYER. CUSTOM MILLWORK PER INT. STAINLESS STEEL SHOWER DRAIN SHOWER OR TUB W/ ANTI-SCALDING FIXTURES MAX. 2.0 GPM@ 80 PSI. PROVIDE 12"Ø CLEANOUT. WALL COVERING OFSHOWER SHALL BE TILE, OR APPROVED EQUAL, TO A HEIGHTOF MIN. 72" ABV. DRAIN INLET. FLOAT TILE OVER CEMENTPLASTER BACKING. NET AREA OF SHOWER ENCLOSURE SHALLNOT BE LESS THAN 7.1 SQ. FT. OF FLOOR AREA W/ A MIN. 30"ØCIRCLE. 17 LAVATORY PER INTERIORS, 1.5 GPM @ 60 PSI 18 CEILING ABOVE PER A_5.0-2 19 TANKLESS WATER HEATER PER T24. PROVIDE A 120V ELEC.OUTLET W/IN 3'; A CATEGORY III OR IV VENT, OR A TYPE BVENT WITH A STRAIGHT PIPE, CONDENSATE DRAIN THAT IS NOMORE THAN 2" ABV. THE FINISH SURFACE BELOW, A GASSUPPLY LINE WITH MIN. 200,000 BTU/HR CAPACITY SYSTEM,MIN. 30"X36" WORKPLACE CLEARANCE IN FRONT. 20 21 RECESSED SHOWER FLOOR 22 23 24 CLEAR TEMPERED GLASS ENCLOSURE & DOOR WINE FRIDGE W/ CUSTOM STL. & GLASS CABINET 24" DISHWASHERS ENERGY STAR QUALIFIED ELECTRIC METER MAIN, MIN. 30"X36" CLEAR IN FRONT, VERIFYWITH SCE X XXXX - NEW DOOR PER SCHEDULE A6.0 - NEW WINDOW PER SCHEDULE A6.0 WASHER & DRYER: WASHER SHALL BE QUALIFIED ENERGYSTAR APPLIANCE WITH MAXIMUM WATER USE FACTOR OF 6GALLONS PER CUBIC FEET OF DRUM CAPACITY. (NBMC15.11.010) CLOTHES DRYER. 4" Ø VENT. USE BLOWER TOVENT THRU ROOF INDICATES EMERGENCY EGRESS W/ MIN. 5.7 SF OPENING (MIN.20" CLEAR WIDTH X 24" CLEAR HEIGHT). RE: A6.0 FORDETAILED REQUIREMENTS. ELECTRICAL SUBPANEL, MAINTAIN 3' CLR. IN FRONT B - 1.5" BRICK ADHERED VENEER O/ CEMENT MORTARBED PER 1/A4.0 C - BRD & BATTEN SIDING 12" O/C SPACING PER 7/A4.0 - 2X6 EXTERIOR WALLS W/ R-21 BATT INSULATION.- 2X4 W/ R-15 @ INTERIOR EXCEPT WHERE REQ'DFOR ROUTING PLUMBING PIPES PROVIDE 2X6CONST. SEE FINISHES BELOW. - RATED WALL PER TYPES BELOWFOR PENETRATION NOTES SEE A_0.2 25 26 27 WAUPACA EXCELEVATOR HYDRAULIC ELEVATOR ANDEQUIPMENT, PROVIDE 12" DEEP PIT PER MFT. SPECS.CONTACT MIKE BURKE (MCKINLEY ELEVATOR): 949-735-0373 28 29 WALL OVEN 30 FURNACE PER ENERGY CALCS & SUBCONTRACTOR DESIGN 31 EXT. OVERHANG ABOVE 32 - HORIZONTAL LAP SIDING, PTD. WHITE PER 4/A4.0 33 34 BAR SINK ICE MAKER 35 NICHE PER INT. 36 COMBO SHOWER AND TUB REFER TO NOTE 2 37 COFFEE STATION W/ WATER SUPPLY38 18" DISH WASHER DRAWER PER INT. SPECS39 COOK TOP W/ SPEED OVEN BELOW PER INT. SPECS40DEFENDER REVERSE OSMOSIS DOMESTIC WATER FILTER41BUILT-IN INFRARED SAUNA, E2H FROM RADIANT SAUNA.42 U/C APPLIANCES & MILLWORK PER LANDSCAPE43SOLAR BACKUP BATTERY, SEE A_0.2 FOR INSTALL. REQS.44 1 2 3 - INT. 1-HR RATED PER 61/A_4.4 4 - EXT. 1-HR RATED PER 63/A_4.4 - EXT. 1-HR RATED PER 64/A_4.4 (BRICK) - 1-HR & 50 STC RATED DEMISING WALL PER 62/A_4.4 MASON-LITE LINEAR MFP-60 W/ PERMANENT GLASS DOORS &DECORATIVE GAS APPLIANCE INSTALLED, TESTED AND LISTEDPER ESR-2401. PROVIDE LISTED 10"Ø TYPE B GAS VENT &SHROUD. CASSETTE HEAT PUMP IN SOFFIT45 Z CLASS 'A' THERMORY PINE, RJ8258F-1 TESTED PER ASTME108 O/ MIN. 2% SLOPE: MER-KO CLASS 'A' WATERPROOFELASTOMERIC MEMBRANE PER IAPMO ER-517 Y X ROOF DRAIN PER 13/A4.0 DECK DRAIN PER 14/A4.0 V ZINC COATED STANDING SEAM METAL AGED VINTAGEFINISH U ZINC COATED HALF ROUND GUTTER W/ AGED VINTAGEFINISH T CUSTOM FIBERGLASS WATERPROOF PLANTER W/INTEGRAL ATRIUM DRAINS & OVERFLOW ROOF NOTES UNVENTED ASSEMBLIES:1. MIN. 1" AIR IMPERMEABLE SPRAY FOAM INSULATION APPLIEDTO THE UNDERSIDE OF THE ROOF SHEATHING W/ BATTINSULATION BELOW. MIN. R-30 TOTAL.2. INTERIOR CLASS I VAPOR RETARDERS ARE NOT INSTALLEDON THE CEILING SIDE (ATTIC FLOOR) OF THE UNVENTED ATTICASSEMBLY OR ON THE CEILING SIDE OF THE UNVENTEDENCLOSED ROOF FRAMING ASSEMBLY.3. PROVIDE R-30 FIBERGLASS BATT FLOOR INSULATION4. OBTAIN FIRE SPRINKLER PERMIT PRIOR TO CALLING FORROOF SHEATHING INSPECTION. S OVERFLOW DRAIN ASSESSORS PARCEL#: 047 202 27 Sca l e : JR WALZ23 CORPORATE PLAZA, SUITE 150NEWPORT BEACH, CA 92660949.836.5977JR@WALZARCHITECTURE.COM WALZ : ARCHITECTURE Clie n t : Pro j e c t : Le g a l D e s c r i p t i o n : Dat e : THIS DRAWING IS THE PROPERTY OF JR WALZ,AND IS NOT TO BE REPRODUCED OR COPIED INWHOLE OR IN PART WITHOUT PERMISSION. ITIS NOT TO BE USED ON ANY OTHER PROJECTAND IS TO BE RETURNED ON REQUEST. BY Cor r e c t i o n s / C h a n g e s : # REVISIONSDATE Se a l / S i g n a t u r e : COASTAL DEVELOPMENT PERMIT (RECHEK#1) Is s u e d F o r : Dra w i n g N o : Co n s u l t a n t s : No t e : Dra w i n g : 2025.08.26KORI & TOBY O'BRIEN O'BRIEN.OCEANFRONT 1624 WEST OCEAN FRONT, NEWPORT BEACH NOTES RID G E : 4 0 . 2 5 RID G E : 4 0 . 4 1 RID G E : 3 6 . 0 8 ' VRIDGE: (+40.41') FROM EST. GRADE) RIDGE: 40.04' RID G E : 3 6 . 0 8 ' VTYP. RID G E : 3 6 . 0 8 ' BRICK CHIMNEYT.O.SHROUD: 42.46' BRICK CHIMNEYT.O.SHROUD: 42.46' T.O. PARAPET: 35.31' T.O. PARAPET: 35.31' T.O . R A I L I N G : 3 5 . 3 1 ' T.O.RAILING: 35.31' T.O.RAILING: 35.31' RIDGE: 40.04' VALLEY RID G E : 4 0 . 1 3 ' 2'-0 " 3'- 2 " 5:12 5:12 5:12 5:12 5:12 5:12 VALLEY VAL L E Y VAL L E Y VAL L E Y VALLEY VALLE Y 3:12 3:123:12 3:12 3:12 3:12 VALLEY VAL L E Y VAL L E Y VALLE Y 6:1 2 6:12 VAL L E Y VAL L E Y VALLEY VALLEY 3:12 3:12 3:1 2 3:123:12 3:1 2 2'-1 0 12" 3'-4 12" 9'-0" 3'- 0 12" SEE A1.2 OPEN TO SKY 2'-0 " 2'-0 ' ' 3'-6 " UP 26 PRO P E R T Y L I N E PRO P E R T Y L I N E PRO P E R T Y L I N E PRO P E R T Y L I N E ASSESSORS PARCEL#: 047 202 27 Sca l e : JR WALZ23 CORPORATE PLAZA, SUITE 150NEWPORT BEACH, CA 92660949.836.5977JR@WALZARCHITECTURE.COM WALZ : ARCHITECTURE Cli e n t : Pro j e c t : Le g a l D e s c r i p t i o n : Date : THIS DRAWING IS THE PROPERTY OF JR WALZ,AND IS NOT TO BE REPRODUCED OR COPIED INWHOLE OR IN PART WITHOUT PERMISSION. ITIS NOT TO BE USED ON ANY OTHER PROJECTAND IS TO BE RETURNED ON REQUEST. BY Co r r e c t i o n s / C h a n g e s : # REVISIONSDATE Se a l / S i g n a t u r e : COASTAL DEVELOPMENTPERMIT (RECHEK#1)Iss u e d F o r : Dra w i n g N o : Co n s u l t a n t s : Not e : Dra w i n g : 2025.08.26KORI & TOBY O'BRIEN O'BRIEN.OCEANFRONT 1624 WEST OCEAN FRONT, NEWPORT BEACH NORTHEAST (SIDE) ELEVATION 3 SOUTHEAST (REAR) ELEVATION 4 ELEVATIONS 1/4"=1'-0"A_2.1 LINEAR ROMAN BRICK VENEER-PTD. WHITE ALUM. CLAD DOORS+WINDOW - WHITE 6" HORIZ. SHIPLAP SIDING 6" HORIZ. SHIPLAP SIDING ALUM. CLAD DOORS+WINDOW - WHITE 6" HORIZ. SHIPLAP SIDING LINEAR ROMAN BRICK VENEER-PTD.WHITE STANDING & SEAM METAL ROOF.AGED VINTAGE FINISH 6" HORIZ. SHIPLAP SIDING LINEAR ROMAN BRICK VENEER-PTD. WHITE CLEAR GLASS GUARDRAIL MIN 40% OPEN CLEAR GLASS GUARDRAIL STANDING & SEAM METAL ROOF. AGED VINTAGE FINISH E2 E1 D3 D2 D1 N3 N4 O1 P2 Q1 Q2 Q3P1 S1 S2 V1 V2 U1 2ND FLOOR +10'-3" 9'-1 " 1'-2 " 8'-0 " 6'-1 0 " 2'-2 " 2'- 0 " T.O.PLATE +9'-1" 104A 115B 119A 118A 309A 28 ' - 1 1 12" F R O M E S T . G R A D E 30' - 1 1 12" F R O M E S T . G R A D E 28' - 8 " F R O M E S T . G R A D E 13' - 1 1 " F R O M E S T . G R A D E 25' - 1 1 12" F R O M E S T . G R A D E 28' - 1 1 12" F R O M E S T . G R A D E 30 ' - 1 1 12" F R O M E S T . G R A D E 2'-0 " 9'- 1 " 1'- 2 " 8'-0 " 1'- 0 " T.O.SLAB: +0'-0" (12.17') 2ND FLOOR +10'-3" T.O.PLATE +18'-3" T.O.PLATE +9'-1" TOP OF UPPER DECK +19'-10" 3ND FLOOR +19'-3" STANDING & SEAM METAL ROOF. AGED VINTAGE FINISH 6'- 1 0 " 2'-2 " T.O.PLATE +26'-1" TOP OF CHIMNEY : +30'-3" 25 ' - 1 1 12" FR O M E S T . G R A D E 2'-0 " 5'-11" TOP OF ROOF : +28'-3" T.O.PLATE +18'-3" TOP OF UPPER DECK +19'-10" 3ND FLOOR +19'-3" T.O.PLATE +26'-1" TOP OF CHIMNEY : +30'-3" TOP OF ROOF : +28'-3" T.O.SLAB: +0'-0" (12.17') EST. GRADE: +11.46 8'-11" 2'- 0 " 1'-0 " 3'-0" 2'-10" 3'-0"5'-0" 3'-1" EST. GRADE: +11.46 N1 N2 M1 M2 M3 M4 M5 S3 R1 R2 HEIGHT CERTIFICATION REQUIRED T.O.WATER TABLE: +10'-4 TYP. 309B DBL. SWING W/ LOUVERED PANELS,PER PLAN 27 PR O P E R T Y L I N E PRO P E R T Y L I N E PR O P E R T Y L I N E PRO P E R T Y L I N E OPP.TYP. TRANSVERSE SECTION 1 SECTIONS 1/4"=1'-0"A_3.0 DINING 101 PANTRY / COFFEE 105 PWDR 108 SAND/SURF 114 ELEV 106 GARAGE 115 CARPORT / OPEN SPACE 120 ALUM. CLAD DOORS+WINDOW - WHITE LINEAR ROMAN BRICK VENEER-PTD. WHITE OFFICE 202 BATH 204 ELEV 206 LAUNDRY 207 BATH 211 SUITE - B 213 CL 214 BATH 215 KITCHEN 216 ROOF DECK 301 BALCONY 203 BBQ 302 ELEV 305 HALLWAY 307 BEDROOM 304 ALUM. CLAD DOORS+WINDOW - WHITE LINEAR ROMAN BRICK VENEER-PTD. WHITE ALUM. CLAD DOORS+WINDOW - WHITE BAR 102 LIVING 103 KITCHEN 104 CL. 109 CL 113 STAIR 112MAIL GARAGE 115 CARPORT / OPEN SPACE 120 MASTER SUITE 201 CLOSET 205 LINEN CL 209 BUNK 212 FAMILY / BONUS 217 ROOF DECK 301 BALCONY 203 BEDROOM 304 COVERED DECK 303 BATH 204 BATH 204 BATH 308 BATH 308 HALLWAY 307 ASSESSORS PARCEL#: 047 202 27 Sca l e : JR WALZ23 CORPORATE PLAZA, SUITE 150NEWPORT BEACH, CA 92660949.836.5977JR@WALZARCHITECTURE.COM WALZ : ARCHITECTURE Clie n t : Pro j e c t : Le g a l D e s c r i p t i o n : Dat e : THIS DRAWING IS THE PROPERTY OF JR WALZ,AND IS NOT TO BE REPRODUCED OR COPIED INWHOLE OR IN PART WITHOUT PERMISSION. ITIS NOT TO BE USED ON ANY OTHER PROJECTAND IS TO BE RETURNED ON REQUEST. BY Cor r e c t i o n s / C h a n g e s : # REVISIONSDATE Se a l / S i g n a t u r e : COASTAL DEVELOPMENT PERMIT (RECHEK#1) Is s u e d F o r : Dra w i n g N o : Co n s u l t a n t s : No t e : Dra w i n g : 2025.08.26KORI & TOBY O'BRIEN O'BRIEN.OCEANFRONT 1624 WEST OCEAN FRONT, NEWPORT BEACH 28' - 1 1 12" F R O M E S T . G R A D E CLEAR GLASS GUARDRAIL MIN 40% OPEN 14' - 2 12" F R O M E S T . G R A D E 23' - 1 0 12" F R O M E S T . G R A D E 30 ' - 1 1 12" F R O M E S T . G R A D E 2ND FLOOR +10'-3" 9'-1 " 1'-2 " 8'-0 " 6'- 1 0 " 2'-2 " 2'- 0 " T.O.PLATE +9'-1" T.O.PLATE +18'-3" TOP OF UPPER DECK +19'-10" 3ND FLOOR +19'-3" T.O.PLATE +26'-1" TOP OF CHIMNEY : +30'-3" TOP OF ROOF : +28'-3" T.O.SLAB: +0'-0" (12.17') 1'-0 " 9'-0" CLEAR GLASS GUARDRAIL MIN 40% OPEN30 ' - 1 1 12" FR O M E S T . G R A D E 2'- 0 " EST. GRADE: +11.46 LINEAR ROMAN BRICK VENEER-PTD. WHITE 2ND FLOOR +10'-3" 9'-1 " 1'-2 " 8'-0 " 6'-1 0 " 2'-2 " 2'- 0 " T.O.PLATE +9'-1" T.O.PLATE +18'-3" TOP OF UPPER DECK +19'-10" 3ND FLOOR +19'-3" T.O.PLATE +26'-1" TOP OF CHIMNEY : +30'-3" TOP OF ROOF : +28'-3" T.O.SLAB: +0'-0" (12.17') 1'-0 " EST. GRADE: +11.46 3A4.0 31A4.2 33A4.2 3A4.0 3A4.0 1A4.0 9A4.0 55A4.3 3A4.0 3A4.0 3A4.0 3A4.0 21A4.1 19A4.1 48A4.3 2A4.0 2 47A4.3 9A4.0 TYP. 3A_4.0 65A_4.4 TYP. 5/8” TYPE X GYPSUM BOARD APPLIED TO THEUNDERSIDE OF FLOOR FRAMING. PROVIDEMINIMUM ½” GYPSUM BOARD ON THE GARAGESIDE ELSEWHERE. TABLE R302.6 8A4.0 44A4.2 3A4.0 5A4.0 5A4.0 31A4.2 8A4.0 9A4.0 28 PRO P E R T Y L I N E PR O P E R T Y L I N E PR O P E R T Y L I N E PRO P E R T Y L I N E PR O P E R T Y L I N E PRO P E R T Y L I N E TRANSVERSE SECTION 3 TRANSVERSE SECTION 4 SECTIONS 1/4"=1'-0"A_3.1 TRANSVERSE SECTION 5 ALUM. CLAD DOORS+WINDOW - WHITE LINEAR ROMAN BRICK VENEER-PTD. WHITE ALUM. CLAD DOORS+WINDOW - WHITE CLEAR GLASS GUARDRAIL BAR 102 LIVING 103 KITCHEN 104 MASTER SUITE 201 CLOSET 205 FAMILY / BONUS 217 ROOF DECK 301 BALCONY 203 BEDROOM 304 COVERED DECK 303 UTILITY 117 STAIR B 118 TRASH / METERS 119 BATH 210 GUEST SUIT - 2 208 BUNK 212 GUEST SUITE - 1 110 111BATH 110 ALUM. CLAD DOORS+WINDOW - WHITE ALUM. CLAD DOORS+WINDOW - WHITE DINING 101 LIVING 103 ALUM. CLAD DOORS+WINDOW - WHITE KITCHEN 104 PANTRY / COFFEE 105 MASTER SUIT 201 BATH 204 CLOSET 205 BATH 204 ROOF DECK 301 BBQ 302 COVERED DECK 303 BBQ 302 BATH 308HVAC309 ASSESSORS PARCEL#: 047 202 27 Sca l e : JR WALZ23 CORPORATE PLAZA, SUITE 150NEWPORT BEACH, CA 92660949.836.5977 JR@WALZARCHITECTURE.COM WALZ : ARCHITECTURE Cli e n t : Pro j e c t : Leg a l D e s c r i p t i o n : Dat e : THIS DRAWING IS THE PROPERTY OF JR WALZ,AND IS NOT TO BE REPRODUCED OR COPIED INWHOLE OR IN PART WITHOUT PERMISSION. ITIS NOT TO BE USED ON ANY OTHER PROJECTAND IS TO BE RETURNED ON REQUEST. BY Co r r e c t i o n s / C h a n g e s : # REVISIONSDATE Sea l / S i g n a t u r e : COASTAL DEVELOPMENTPERMIT (RECHEK#1)Iss u e d F o r : Dra w i n g N o : Con s u l t a n t s : No t e : Dra w i n g : 2025.08.26KORI & TOBY O'BRIEN O'BRIEN.OCEANFRONT 1624 WEST OCEAN FRONT, NEWPORT BEACH 9'-1 " 1'- 2 " 8'-0 " 6'- 1 0 " 2'-2 " 2'- 0 " T.O.PLATE +18'-3" TOP OF UPPER DECK +19'-10" 3ND FLOOR +19'-3" T.O.PLATE +26'-1" TOP OF ROOF : +28'-3" T.O.SLAB: +0'-0" (12.17') 1'- 0 " T.O.PLATE +9'-1" 2ND FLOOR +10'-3" TOP OF CHIMNEY : +30'-3" 9'-1 " 1'-2 " 8'-0 " 1'-0 " T.O.SLAB: +0'-0" (12.17') 2ND FLOOR +10'-3" T.O.PLATE +18'-3" T.O.PLATE +9'-1" TOP OF UPPER DECK +19'-10" 3ND FLOOR +19'-3" STANDING & SEAM METAL ROOF. AGED VINTAGE FINISH 6'-1 0 " 2'-2 " T.O.PLATE +26'-1" TOP OF CHIMNEY : +30'-3" 2'-0 " EST. GRADE: +11.46 TOP OF ROOF : +28'-3" 9'-1 " 1'-2 " 8'-0 " 1'-0 " T.O.SLAB: +0'-0" (12.17') 2ND FLOOR +10'-3" T.O.PLATE +18'-3" T.O.PLATE +9'-1" TOP OF UPPER DECK +19'-10" 3ND FLOOR +19'-3" STANDING & SEAM METAL ROOF. AGED VINTAGE FINISH 6'-1 0 " 2'-2 " T.O.PLATE +26'-1" TOP OF CHIMNEY : +30'-3" 2'-0 " EST. GRADE: +11.46 TOP OF ROOF : +28'-3" 30'- 8 " F R O M E S T . G R A D E 28' - 8 " F R O M E S T . G R A D E EST. GRADE: +11.46 28'- 6 " F R O M E S T . G R A D E 30 ' - 8 " F R O M E S T . G R A D E 3A4.0 3A4.0 9A4.0 34A4.2 21A4.1 19A4.1 36A4.2 34A4.2 9A4.0 3A4.0 3A4.0 3A4.0 3A4.0 3A4.0 3A4.0 3A4.0 21A4.1 18A4.1 1A4.0 9A4.0 304A304A 16A4.1 5A4.0 19A4.1 9A4.0 55A_4.3 29 PRO P E R T Y L I N E PR O P E R T Y L I N E PRO P E R T Y L I N E PRO P E R T Y L I N E TRANSVERSE SECTION 6 SECTIONS 1/4"=1'-0"A_3.2 TRANSVERSE SECTION 7 ALUM. CLADDOORS+WINDOW - WHITE HALLWAY 307 BATH 210 BATH 211 SAND/SURF 114 STAIR 112 BATH 111 KITCHEN 216 FAMILY / BONUS 217 TRASH / METERS 119 CARPORT / OPEN SPACE 120 HVAC 309 ASSESSORS PARCEL#: 047 202 27 Sca l e : JR WALZ23 CORPORATE PLAZA, SUITE 150NEWPORT BEACH, CA 92660949.836.5977JR@WALZARCHITECTURE.COM WALZ : ARCHITECTURE Clie n t : Pro j e c t : Le g a l D e s c r i p t i o n : Dat e : THIS DRAWING IS THE PROPERTY OF JR WALZ,AND IS NOT TO BE REPRODUCED OR COPIED INWHOLE OR IN PART WITHOUT PERMISSION. ITIS NOT TO BE USED ON ANY OTHER PROJECTAND IS TO BE RETURNED ON REQUEST. BY Cor r e c t i o n s / C h a n g e s : # REVISIONSDATE Se a l / S i g n a t u r e : COASTAL DEVELOPMENT PERMIT (RECHEK#1) Is s u e d F o r : Dra w i n g N o : Co n s u l t a n t s : No t e : Dra w i n g : 2025.08.26KORI & TOBY O'BRIEN O'BRIEN.OCEANFRONT 1624 WEST OCEAN FRONT, NEWPORT BEACH 9'-1 " 1'- 2 " 8'- 0 " 1'-0 " T.O.SLAB: +0'-0" (12.17') 2ND FLOOR +10'-3" T.O.PLATE +18'-3" T.O.PLATE +9'-1" TOP OF UPPER DECK +19'-10" 3ND FLOOR +19'-3" 6'-1 0 " 2'-2 " T.O.PLATE +26'-1" EST. GRADE: +11.46 TOP OF ROOF : +28'-3" 9'-1 " 1'- 2 " 8'- 0 " 1'-0 " T.O.SLAB: +0'-0" (12.17') 2ND FLOOR +10'-3" T.O.PLATE +18'-3" T.O.PLATE +9'-1" 3ND FLOOR +19'-3" EST. GRADE: +11.46 11A4.0 9A4.0 3A4.0 3A4.0 TYP. 48A4.3 OPP. OPP.47A4.3 3A4.0 TYP.OPP.47A4.3 3A4.0 3A4.0 3A4.0 1A4.0 3A4.0 19A4.2 3A4.0 8A4.0 11A4.0 5A4.0 OPP.TYP. 47A4.3 11A4.0 19A4.0 21A4.0 ELEVATOR 305 6'-0 " M A X MECHANICAL 306 THIRD FLOOR MECHANICAL ROOM SECTION 8 30 31 (9.9 1 F S ) (10 . 2 7 F S ) (12 . 0 9 F S ) (14.51TW)W(13.72FS) (10.77FS)(11.78FS) (11. 1 7 F S ) (11.56FS)5(11.86FS)(1(((( (10 . 0 8 F S ) (10.59GF) (31.81)TOR (39. 3 6 ) TOR (36 . 0 4 ) TOR (14.57TW)(13. 8 4 F S ) (11.46FS)( (13.26FS) (13.26TW) (10.75FS) WM(10.1 8 F S ) (10.33FS) (10. 4 3 F S ) (( 2 S T O R Y BU I L D I N G 2 S T O R Y BU I L D I N G 2 S T O R Y BU I L D I N G 2 S T O R Y BU I L D I N G 1 S T O R Y BU I L D I N G UTI L I T Y EDISON BOX BO X GAR A G E GMGGM 2ND STORYBUILDING LINE (12.05FF)(11.08FS) (10.93FS) (14.14FF) (14.1FS) DEC K LIN E PAL M (22.79) )DECK (37.61)RIDGE (37.69)TOP OF RAILING (14.02FF) (34.80)DECK (12.73 F S ) (1 2 . 0 8 F S ) (12.1 1 F S ) (13 . 9 2 F S ) (13 . 8 7 F S ) ) ( (13.70FS)(11.89FS)(11.65FS)(11. 3 6 F S ) (10.90FS)(10.57FS) (11.35FS)(13. 2 6 F S ) (13.55FS) (11 . 8 5 F S ) (11 . 7 9 F S ) (11.75FS) (9.8 5 F S ) (9.88FS) (9.8 4 F S ) (9.42FL) (9.50FL) (9.5 9 F L ) (11.54FS)(12.61FS) DEC K LINE (10.46FS) (10. 0 0 F S ) XX XX XX XX XXX XX PL A S T I C FE N C E XX XXXXX XXXXXXX XXX XXX XXX XXXX XXXXXXXXXXX X X SE A R C H E D , FO U N D N O T H I N G SE A R C H E D , EEESFO U N D N O T H I N G SEA R C H HHE D , HHH FO U N D N O T H I N G SE A R C H E D , FO U N D N O T H I N G PIL A S T E R ) CEN T E R LINE DIRT DIRT (9. 8 9 F S ) 89F89F89F S)S) (10 . 6 5 F S ) (10.36FS )3F0.36FS) (12.78 T W ) 7..TWTWWTTTTTT...((12.78 T W TTT(13.32T W ) 3 TWTW) ( (11. 8 2 F S ) (14.63TW) TWW) (14 (12. 1 4 F S ) (13 . 9 0 F S ) (14.05FS) ) (11.67FS)6 11. 0 9 F S ) (11 . 0 F S ) ( ( )GG DDTT(9(9 SS))) WMWM )) FSFS FOOUUNDDNOOTTHHINNGG FSFS)S) ( XXXX XXXX XXXX XXX X X ) ) ) 63TT 14 WTWW 4 W)) 6 WW) ((1( 8FS X (1 X X X X X ( F 8 8(1 R 1 YDU ) 3 12 10 S N R GN 5 F FS 81T 0 18 YT F U 10 W X X ) ) 10 S (3 OS) E 0 F D 57 F0S S) ) 0 S) O 3 TT S) L F D 0 57 F W X S 12 . 01 YIU 0 3 .S) 3 S) EO 0 W) 4 2 3 OI 0 F 32( 04 ) (3 R 2X 0 L 7F (X )5)6 X S)) OR 36 W ) X (10 L S D 7 S ) X )) XX 43 1 27 33 S) NL 1 (1 (6 WWW ( O S7 (10 )2 (4 1R X I S) 2 F )9 13X 4 X 18 10 7 G RLB ( S) 0 ( T3XX 1 (1 6F W)X NS 5 N . 3XF XX ) ( X R G S D 3 3 FF2 )S))S))CC (10(10(10(10(10(10(10 ((((((((( ND 1 2 333333 44444 9FFSS)S) (10 12.17 T/SLABXXX.XX PAD PROPOSED RESIDENCE OC E A N F R O N T W AL L E Y LLLLLLL Y LL ) W) (13 9 2 F S ) TW ) LIN E W) PAL M DEC K D (1 (22 EC (1 8 3 9 0 F S ) 79K FS ) ) ( 3T 3D 3. O ( 4E 70F 9 4 0K 1 XX DEC K K 73F I S R X XXXX TO(3 OR (32FS) 39.3 RS)F 02FF F 0 F 0 S) ( S)S) (1 ) (1 8FS)8FS)S) DEC K K FF ))S) GMG FF)( 5 FS 45 4FS 5 FS (14 84 (14414 XXXX )XXXX XXXX )XXXXX ))))))X XXX)XX)X X )XX)X X )X ) ))) (1(1XXXXXXXXXXXXXXXXXX) (1( BUILDLINGL FOFOOSE A SE A UUNUNNNNNAR CUNAUUULINEENLINNEEINNEE GARAGE ((12 HEHHHN F) TILBO(905RYIKKE333KKN .56 W))) 00.33 A ((1 ( WWWW4FF TOPTOOFFFF DXXXX (37.611) WWWWWWTTTWWWWWWWTWWTWW)WWWTWTWTWTWTWTWTWTWTWTTTWTTWTWTWTWTWTWTWTWTWTWTWWWWWWWWWWWWWTWWTWTWTWTWTWTWTTTTTWWWWWWTWTWTWTWWWWTWWWTWTWTWTWTWTWTTWWTTTWTWWWTWTWTWTWTWTWTWTWTWTWTWTWTWTWTWTWTWTWTWTWTWTWTWTWTWTWTWTWTWTWTWTWTWTWTWTWTWTWTWTWTWTWTWTWTWTWTWTWTWWWWWWWWWWWWWWWWWWWW ))))))))))))))))))))) )))) XX 777X78TTT8TXXXTWWTWWTTTTT FS)S)7FSFS )1)1))) ONONNONONN (10 3 0(1 .43(10 3 3 43F6F463FFF75(10 7 (100))))((XXXFS)(11.5441FS)S)1(12 6(FS)FF)(10.939XXFS)(11 54(41FS)F(12 62(126(13 2 (3(13(373F3F2.777(12 7 17 87 ) 3 9 0 F S 3(1 F7F 575545454 CK 227K 27 XXXDDXIRTRXX 3.32T322TTTT2TT 6F66FFF6666F6 (13(13(13(13313133(1313 GAAARAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA 3FF3F3F33F3FFF3F3333333F3F3FFFFFFF3F3F3FFFFFFF3F3F3F333333333FS)FS)FS)FS)FS)FSFFSFSFSS)FS)FS)FSFFFSFSFSFSFSFSFSFSFSFFFFFFFFS)S)FS)FS)S)FS)FS)S)FS) AAAAAAGGGAGRA G RAR E F))G 33F3F33F 9GG 3333333 59G5(100 (1 10.0 10034.80)4 0 (12(12((((( FS (1 FFFFF XXXX CNCEN (1 3.2 (10 5 ONOHED THH,THDDOO W(9. 8 1.11(((((1.0 9 F 8FFS)S)) 11. 55 1S I HHHEHHHN 7373FS)3FS737 XXXX .10010(10 EAU XXXXXXXXXXXX ( LINE DATA CONSTRUCTION NOTES KEY NOTES LEGEND 139 Avenida NavarroSan Clemente, CA 92672949.492.8586www.toalengineering.com CIVIL ENGINEERINGLAND SURVEYINGSTORMWATER QUALITY A B C D E F G H 1 2 3 4 5 6 ABC D E F G H PRELIMINARY PLAN NOT FOR CONSTRUCTION ADAM L. TOALR.C.E. 59275 DATE: No. 59275REGISTEREDPRORRFESSIONANN LENG INEER STATEOFCACLIFORNIA ADAM TOAOO L CIVIL 1"=8' N/A11/5/24 8/13/25 A.L.T. A.L.T. A.L.T. 1 3 C-1 PR E L I M I N A R Y GRA D I N G & D R A I N A GE PL A N 25051 TBD O'B R I E N R E SID E N CE LOT 1 2 , B L OCK 1 6 , N E W P ORT B E A C H S E C T I ON B 1624 W . OC EA N F R ONT THOMAS O'BRIEN .... NOTICE TO CONTRACTORREQUIRED CERTIFICATIONS / APPROVALS In addition to any certifications required by the agencies having jurisdiction over this project, the following approvals from the Civil engineer of record are required: 1. Foundation forms for improvements on or abutting property lines is required prior to concrete pour. 2. Location, size, and depth of all drain lines prior to backfill. 3.Stormwater Best Management Practices (BMPs) at each significant construction stage and atproject completion to ensure that BMPs have been constructed and/or installed in accordance with the approved Grading Plan and Water Quality Management Plan. MISCELLANEOUS NOTES DRAINAGE SYSTEM NOTETEES AND 90° BENDS SHALL NOT BE INSTALLED IN THE SITE DRAINAGE SYSTEM WITHOUT PRIOR APPROVAL FROM THE CIVIL ENGINEER. MAINTENANCE NOTE THE PROPERTY ONWER IS RESPONSIBLE FOR PROPER INSPECTION AND MAINTENANCE OF DRAINAGE SYSTEMS, INCLUDING INLETS, PIPES, TREATMENT DEVICES, FILTERS, STORAGE BASINS, ETC., WHICH IS NECESSARY FOR PROPER OPERATION OF THE DRAINAGE SYSTEM AND PROTECTION OF SITE IMPROVEMENTS. 32 SECTION SECTION CONSTRUCTION NOTES DETAILFLOW DIVERSION BOX 139 Avenida NavarroSan Clemente, CA 92672949.492.8586www.toalengineering.com CIVIL ENGINEERINGLAND SURVEYINGSTORMWATER QUALITY A BCDEFGH 1 2 3 4 5 6 ABCDEFGH PRELIMINARY PLAN NOT FOR CONSTRUCTION ADAM L. TOALR.C.E. 59275 DATE: No. 59275REGISTEREDPRORRFESSIONANN LENG INEER STATEOFCACLIFORNIA ADAM TOAOO L CIVIL NOTED N/A11/5/24 8/13/25 A.L.T. A.L.T. A.L.T. 2 3 C-2 SECTI ONS A N D D E T A I L S 25051 #### O'B R I E N R E SID E N CE LOT 1 2 , B L OCK 1 6 , N E W P ORT B E A C H S E C T I ON B 1624 W . OC EA N F R ONT THOMAS O'BRIEN .... SECTION NOTES: DETAILTYPICAL DRAIN INLET DETAILTYPICAL BUILDING DRAINAGE AT LANDSCAPING DETAILTYPICAL BUILDING DRAINAGE AT HARDSCAPEDETAILTYPICAL SIDE YARD SWALE 33 (9.9 1 F S ) (10 . 2 7 F S ) (12 . 0 9 F S ) (14.51TW)W(13.72FS) (10.77FS)(11.78FS) (11. 1 7 F S ) (11.56FS)5(11.86FS)(1(((( (10 . 0 8 F S ) ((11.46F (13.26TW WM 2 STORY BU I L D I N G 2 S T O R Y BU I L D I N G 2 S T O R Y BU I L D I N G 1 S T O R Y BU I L D I N G UTI L I T Y EDISON BOX BO X (1 2 . 0 8 F S ) (12.1 1 F S )(11 . 8 5 F S ) (11 . 7 9 F S ) (11.75FS) (9.8 5 F S ) (9.88FS) (9.8 4 F S ) (9.42FL) (9.50FL) (9.5 9 F L ) (10.46FS) (10. 0 0 F S ) XX XXXX PL A S T I C FE N CE X X SE A R C H E D , FO U N D N O T H I N G SE A R C H E D , EEESFO U N D N O T H I N G SEA R C H E D , HHH FO U N D NO TH I NG SE A R C H E D , FO U N D N O T H I N G PIL A S T E R ) CEN T E R LINE DIRT S)S) (9. 8 9 F S ) 89F89F89F (10 . 6 5 F S ) (12. 1 4 F S ) (11.67FS)6 11. 0 9 F S ) X X ) ) ) )S))S))CC (10(10(10(10(10(10(10 ((((((((( ND 9FFSS)S (10 12.17 T/SLABXXX.XX PAD PROPOSED RESIDENCE OC E A N F R O N T W AL L E Y ) W) FOOSE A SE A UNNNAR CUNAU GARAGE .56EAU( .4 139 Avenida NavarroSan Clemente, CA 92672949.492.8586www.toalengineering.com CIVIL ENGINEERINGLAND SURVEYINGSTORMWATER QUALITY A BCDEFGH 1 2 3 4 5 6 ABCDEFGH PRELIMINARY PLAN NOT FOR CONSTRUCTION ADAM L. TOALR.C.E. 59275 DATE: No. 59275REGISTEREDPRORRFESSIONANN LENG INEER STATEOFCACLIFORNIA ADAM TOAOO L CIVIL 1"=8' N/A11/5/24 8/13/25 A.L.T. A.L.T. A.L.T. 3 3 C-3 CO NSTR UC TI ON P OLL UTI ON PR E V E N T I ON P L A N 25051 TBD O'B R I E N R E SID E N CE LOT 1 2 , B L OCK 1 6 , N E W P ORT B E A C H S E C T I ON B 1624 W . OC EA N F R ONT THOMAS O'BRIEN .... NOTE EROSION CONTROL BMPs TEMPORARY SEDIMENT CONTROL WIND EROSION CONTROL TRACKING CONTROL WASTE MANAGEMENT AND MATERIALS POLLUTION CONTROL NON-STORMWATER MANAGEMENT THIS SHEET FOR EROSION CONTROL ONLY BMP REQUIREMENTS EROSION CONTROL MAINTENANCE LEGEND 34 18 " 48" 18 " 18" 18 " 36" 30" TALL 30" TALL 30" TALL TREE PLANTING LEGEND: CONTAINER SHRUB PLANTING LEGEND: COCEPTUAL LADSCAPE DESIG PLA VIEW 024 8 16 PLA VIEW SCALE: 1/4"=1' L-1 O'BRIE RESIDECE 1624 W. OCEA FROT EWPORT BEACH, CA 92663 PREPARED FOR: Mr. & Mrs. O'Brien 1624 W. Ocean Front ewport Beach, CA 92663 ROOF TOP DECK GROUND FLOOR PATIO TOTAL SQ FT OF NEWLY LANDSCAPE AREA: 48 SQ. FT. 35 COCEPTUAL LADSCAPE DESIG ELEVATIOS SECTIO - ASCALE: 1/4"=1' L-2 O'BRIE RESIDECE 1624 W. OCEA FROT EWPORT BEACH, CA 92663 PREPARED FOR: Mr. & Mrs. O'Brien 1624 W. Ocean Front ewport Beach, CA 92663 36