HomeMy WebLinkAboutRS001060 - MISCCOUNTY OF ORANGE PLAN CHECK CORRECTION LIST Charles L. Howell Architect 570 Glenneyre Street Laguna Beach Ca 92651 December 18, 2000 PLAN CHECK NO. RS00-1059&1060 ADDRESS 18 shortline Dr Newport Coast OCCUPANCY R3/U1 AREA-S.F. 5167(R3)/941(U1) TYPE-OF-CONST. VN Spkd The submitted plans and specifications have been reviewed by VANDORPE CHOU ASSOCIATES. In our professional opinion the plans indicate that the work will conform to the building codes and regulations adopted by the COUNTY OF ORANGE and the State of California Amendment. APPROVAL FOR BUILDING PERMIT PURPOSES IS HEREBY RECOMMENDED SUBJECT TO OBTAINING APPROVALS/CLEARANCES FROM ALL APPLICABLE COUNTY DEPARTMENTS, AGENCIES, AND ASSOCIATIONS. Plans checked by: Shahla Soltani VANDORPE CHOU ASSOCIATES 295 N Rampart Street, Suite A Orange, CA 92868 (714) 978-9780 VCA File No. ORCO-12098&99 1 SOUTHLAND ENERGY CONSULTANTS IIVAC PLUMBING ELECTRICAL DESIGN * TITLE 24 CALCULATIONS In LE 24 ENERGY ANALYSIS FOR: THE HAGUE RESIDENCE 18 SHORELINE DRIVE - PELICAN POINT NEWPORT COAST, CALIFORNIA 1491 GLENNEYRE STREET, LAGUNA BEACH, CA 92651 PHONE 949 497-3591 * FAX 949 497-3210 TITLE 24 SUMMARY PROJECT NAME: TIIE HAGUE RESIDENCE 18 SHORELINE DRIVE -PELICAN POINT NEWPORT BEACH, CALIFORNIA STANDARD DESIGN ENERGY USE: 13.75 KBTU/ SF-YR PROPOSED DESIGN ENERGY USE: 13.46 KBTU/ SF-YR **BUILDING COMPLIES** ITEMS NEEDED FOR COMPLIANCE WITH 111'LE 24 STANDARDS/ REGULATIONS: GLAZING GLAZING TO BE SINGLE. NO INTERIOR SHADING REQUIRED. INSULATION ATTIC SPACES: R-19 SLOPE/ FLAT CEILING JOIST SPACES: R-19 EXT. WALLS: R-13 RAISED FLOORS: N/A FURNACE UP - BDP#383K036055 53KBTUH .80 AFUE DN - BDP#383K060090 89KBTUH .80 AFUE BSMT. - BDP#383K024035 35KBTUH .80 AFUE OR APPROVED EQUALS. CONDENSING UNIT UP - BDP#561A 036 36KBTUH 10.0 SEER DN - BDP#561A-060 60KBTUH 10.0 SEER BSMT. - BDP#561A 0224 24KBTUH 10.0 SEER OR APPROVED EQUAL. WATER H EATER AMERICAN G52-100T88-4NV 100 GAL. R 16INT. INSUL. W/RECIRC.PUMP. OR APPROVED EQUAL. THERMAL MASS INDICA:1'E ON FLOOR PLAN WHERE HARD SURFACED FLOORS ARE TO BE INSTALLED (TILE, VINYL, WOOD, ETC.) OVER SLAB. TILE COUNTERTOPS, TUB SURROUNDS, TILE SHOWER STALLS, ETC. REQUIRED SIGNATURES INDIVIDUAL WITH OVERALL DESIGN RESPONSIBILITY OR THE BUILDING OWNER MUST SIGN PAGE 3 OF CF-1R (THIS DOCUMENT) AND NOTE SHEET CF-1R. -TABLE OF CONTENTS TOC Project Title Project Address Documentation Author. Climate Zone Compliance Method HAGUE RESIDENCE 18 SHORELINE DRIVE NEWPORT BEACH CA. PAUL KANDARIAN Southland Energy Consultants 1491 Glenneyre Street Laguna Beach, CA 92651 949-497-3591 06 MICROPAS5 v5.00 for 1999 Date..09/17/99 09:11:45 ******* *v5.00* ******* Standards Building Permit # Plan Check / Date Field Check/ Date by Enercomp, Inc. MICROPAS5 v5.00 File-HAGUE Wth-CTZO6S92 Program-TOC User#-MP0298 User -Southland Energy Consulta Run -NEW RESIDENCE TABLE OF CONTENTS Report FORM CF-1R FORM C-2R HVAC SIZING Page 1 4 7 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF-1R Project Title Project Address Documentation Author. Climate Zone HAGUE RESIDENCE 18 SHORELINE DRIVE NEWPORT BEACH CA. . PAUL KANDARIAN Southland Energy Consultants 1491 Glenneyre Street Laguna Beach, CA 92651 949-497-3591 06 ******* *v5.00* ******* Date..09/17/99 09:11:45 Compliance Method MICROPAS5 v5.00 for 1999 Standards Building Permit # Plan Check / Date Field Check/ Date by Enercomp, Inc. MICROPAS5 v5.00 File-HAGUE Wth-CTZO6S92 Program -FORM CF-1R User#-MP0298 User -Southland Energy Consulta Run -NEW RESIDENCE GENERAL INFORMATION Conditioned Floor Area Building Type Construction Type Building Front Orientation Number of Dwelling Units Number of Stories Floor Construction Type Glazing Percentage Average Glazing U-value Average Glazing SHGC - Component Type Wall -Roof Floor "__ SlabEdge SlabEdge 5320 sf Single Family Detached New Front Facing 0 deg (N) 1 3 Slab On Grade 18.9 % of floor area 0.95 Btu/hr-sf-F 0.74 BUILDING SHELL INSULATION Frame Cavity Sheathing Total Assembly Type R-value R-value R-value U-value Location/Comments Wood Wood Wood None None R-13 R-0 R-13 0.088 R-19 R-0 R-19 0.051 R-19 R-0 R-19 0.037 TO CRAWLSPACE R-0 R-0 F2=0.900 To Outside R-0 R-0 F2=0.720 To Outside Area - Orientation (sf) Window Front (N) Door Front (N) - Window Left (E) Door Left (E) Window Back (S) Door._Back (S) Window Right (W) Door Right (W) 58.0 22.0 193.0 81.0 160.0 150.0 112.0 232.0 FENESTRATION U- Interior Value SHGC Shading 0.920 0.990 0.920 0.990 0.920 0.990 0.920 0.990 0.740 0.740 0.740 0.740 0.740 0.740 0.740 0.740 Standard Standard Standard Standard Standard Standard Standard Standard Exterior Shading Standard Standard Standard Standard Standard Standard Standard Standard Over- hang/ Fins Yes Yes Yes Yes Yes Yes Yes Yes ,_ CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF-1R Project Title HAGUE RESIDENCE Date..09/17/99 09:11:45 MICROPASS v5.00 File-HAGUE Wth-CTZO6S92 Program -FORM CF-1R User#-MP0298 User -Southland Energy Consulta Run -NEW RESIDENCE Type SlabOnGrade InteriorHorz THERMAL MASS Area Thickness Exposed (sf) (in) Location/Comments Yes 1388 3.5 BASEMENT, TYP. Yes 736 1.0 CNTRS/SHWRS/TUBS HVAC SYSTEMS Minimum Duct Duct Tested Duct ACCA Thermostat ----Equipmdnt Type Efficiency Location R-value Leakage Manual D Type Furnace 0.800 AFUE Attic R-4.2 No No Setback ACSplit 10.00 SEER Attic R-4.2 No No Setback WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R-value Storage *** *** *** Gas Recirc/TimeTemp 1 0.44 100 R-12 SPECIAL FEATURES AND MODELING ASSUMPTIONS Items in this section should be documented on the plans, installed to manufacturer and CEC specifications, and verified during plan check and field inspection. *** *** *** 7-This building incorporates a High Mass Design. -Mandatory Measures require a R-12 or greater external blanket on Gas Storage Water Heaters with Energy Factors less than 0.58. REMARKS CEC DEFAULT U-VALUES USED. NO FORMS 3R REQUIRED. FRONT: STREET FACING FACADE.(RES.MANUAL P.G-24) - FAU UP: BDP#383K036055 53 KBTUH .80 AFUE FAU DN: BDP#383K060090 89 KBTUH .80 AFUE FAU BSMT.: BDP#383K024035 35 KBTUH .80 AFUE A/C UP: BDP#561A-036 36 KBTUH 10.0 SEER A/C DN: BDP#561A-060 60 KBTUH 10.0 SEER A/C BSMT.: BDP#561A-024 24 KBTUH 10.0 SEER WH: AMERICAN#G52-100T88-3NV 100 GAL. R-16 INT.INSUL. W/RECIRC. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF-1R Project Title HAGUE RESIDENCE Date..09/17/99 09:11:45 MICR0PAS5 v5.00 File-HAGUE Wth-CTZO6S92 Program -FORM CF-1R User#-MP0298 User -Southland Energy Consulta Run -NEW RESIDENCE COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features Modeling Assumptions section. Name.... Company. Address. Phone... License. Signed.. Name.... Title... Agency.. Phone... Signed.. DESIGNER or OWNER CHARLES L. HOWELL ARCHITECT 570 GLENNEYRE STREET LAGUNA BEACH CA. 92651 949-497-2134 //e,1(1 ENFORCEMENT AGENCY (date) (date) DOCUMENTATION AUTHOR Name.... PAUL KANDARIAN Company. Southland Energy Consultants Address. 1491 Glenneyre Street Laguna Beach, CA 92651 Phone... 949-497-3591 1(n(11 (date) Certified Energy Analyst Paul E. Kandarian R 98-93-201 rr rr CADEC California Association of Building Energy Consultants C-2R COMPUTER METHOD SUMMARY Page 4 Project Title Project Address Documentation Author.. Climate Zone Compliance Method HAGUE RESIDENCE 18 SHORELINE DRIVE NEWPORT BEACH CA. PAUL KANDARIAN Southland Energy Consultants 1491 Glenneyre Street Laguna Beach, CA 92651 949-497-3591 06 MICROPAS5 v5.00 for 1999 Date..09/17/99 09:11:45 ******* *v5.00* ******* Standards Building Permit # Plan Check / Date Field Check/ Date by Enercomp, Inc. MICROPAS5 v5.00 File-HAGUE Wth-CTZ06S92 Program -FORM C-2R User#-MP0298 User -Southland Energy Consulta Run -NEW RESIDENCE MICROPAS5 ENERGY USE SUMMARY Energy Use (kBtu/sf-yr) Space Heating Space Cooling Water Heating Standard Design 5.51 2.88 5.36 Proposed Compliance Design Margin 5.65 1.63 6.18 -0.14 1.25 -0.82 Total 13.75 13.46 0.29 *** Building complies with Computer Perfotrance *** GENERAL INFORMATION Conditioned Floor Area Building Type Construction Type Building Front Orientation Number of Dwelling Units Number of Building Stories Weather Data Type Floor Construction Type Number of Building Zones Conditioned Volume Slab -On -Grade Area Glazing Percentage Average Glazing U-value. Average Glazing SHGC Average Ceiling Height Zone Type BUILDING ZONE 5320 sf Single Family Detached New Front Facing 0 deg (N) 1 3 ReducedYear Slab On Grade 1 53200 cf 1388 sf 18.9 % of floor area 0.95 Btu/hr-sf-F 0.74 10 ft INFORMATION Floor Area Volume (sf) (cf) # of Dwell Cond- Thermostat Units itioned Type Vent Vent Height Area (ft) (sf) HOUSE ,_ Residence 5320 53200 1.00 Yes Setback 8.0 Standard Air Leakage Credit C-2R Orientation - COMPUTER METHOD SUMMARY - Project Title HAGUE RESIDENCE Page 5 Date..09/17/99 09:11:45 MICROPAS5 v5.00 File-HAGUE Wth-CTZO6S92 Program -FORM C-2R User#-MP0298 User -Southland Energy Consulta Run -NEW RESIDENCE Surface OPAQUE SURFACES Area U- Insul Act Solar Form 3 (sf) value R-val Azm Tilt Gains Reference Location/ Comments HOUSE 90 Yes W.13.2X4.16 1 Wall 1280 0.088 13 0 2 Wall. 1536 0.088 13 90 90 Yes W.13.2X4.16 3 Wall 1050 0.088 13 180 90 Yes W.13.2X4.16 4 Wall 1466 0.088 13 270 90 Yes W.13.2X4.16 5 Roof 2960 0.051 19 n/a 0 Yes R.19.2X8.16 6 Floor 896 0.037 19 n/a 0 No FC.19.2X8.16 TO CRAWLSPACE PERIMETER LOSSES 'Surface Length F2 Insul Solar (ft) Factor R-val Gains Location/Comments HOUSE M- 7 SlabEdge 105 0.900 R-0 No To Outside 8 SlabEdge 75 0.720 R-0 No To Outside FENESTRATION SURFACES Area U- Act Exterior Shade Interior Shade (sf) Value SHGC Azm Tilt Type/SHGC Type/SHGC HOUSE Door Front (N) 58.0 0.920 0.740 0 90 Standard/0.76 Standard/0.68 2 D 1 Window Front (N) 22.0 0.990 0.740 0 90 Standard/0.76 Standard/0.68 3 Window Left (E) 193.0 0.920 0.740 90 90 Standard/0.76 Standard/0.68 4 Door Left (E) 81.0 0.990 0.740 90 90 Standard/0.76 Standard/0.68 5 Window Back (S) 160.0 0.920 0.740 180 90 Standard/0.76 Standard/0.68 6 Door Back (S) 150.0 0.990 0.740 180 90 Standard/0.76 Standard/0.68 7 Window Right (W) 112.0 0.920 0.740 270 90 Standard/0.76 Standard/0.68 8 Door Right (W) 232.0 0.990 0.740 270 90 Standard/0.76 Standard/0.68 OVERHANGS AND SIDE FINS Window- Overhang Left Fin Right Fin - Area Left Rght Surface (sf) Wdth Hgth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght HOUSE 1 Window 58.0 n/a 5.0 2.0 0.5 n/a n/a n/a n/a n/a n/a n/a n/a 2 Door 22.0 n/a 6.7 2.0 0.5 n/a n/a n/a n/a n/a n/a n/a n/a 3 Window 193.0 n/a 5.0 2.0 0.5 n/a n/a n/a n/a n/a n/a n/a n/a 4 Door 81.0 n/a 6.7 2.0 0.5 n/a n/a n/a n/a n/a n/a n/a n/a 5 Window 160.0 n/a 5.0 2.0 0.5 n/a n/a n/a n/a n/a n/a n/a n/a 6 Window 150.0 n/a 6.72.0 0.5 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 7 iridow 112.0 n/a 5.00 8 Door 232.0 n/a 6.7 2.0 0.5 n/a n/a n/a n/a n/a n/a n/a n/a COMPUTER METHOD SUMMARY Page 6 C-2R Project Title HAGUE RESIDENCE Date..09/17/99 09:11:45 MICROPAS5 v5.00 File-HAGUE Wth-CTZO6S92 Program -FORM C-2R User#-MP0298 User -Southland Energy Consulta Run -NEW RESIDENCE. Mass Type THERMAL MASS Area Thick Heat Conduct- Surface (sf) (in) Cap ivity UIMC R-value Location/Comments HOUSE 1 SlabOnGrade 1388 3.5 28.0 0.98 4.60 R-0.0 BASEMENT, TYP. 2 InteriorHorz 736 1.0 24.0 0.67 1.70 R-0.0 CNTRS/SHWRS/TUBS System Type HOUSE Furnace ACSplit HVAC SYSTEMS Minimum Duct Duct Tested Duct ACCA Duct Efficiency Location R-value Leakage Manual D Eff 0.800 AFUE Attic 10.00 SEER Attic R-4.2 No R-4.2 No WATER HEATING SYSTEMS No No 0.794 0.747 Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R-value 1 Storage Gas Recirc/TimeTemp 1 0.44 100 R-12 *** *** *** SPECIAL FEATURES AND MODELING ASSUMPTIONS Items in this section should be documented on the plans, installed to manufacturer and CEC specifications, and verified during plan check and field inspection. *** *** *** This building incorporates a High Mass Design. Mandatory Measures require a R-12 or greater external blanket on Gas Storage Water Heaters with Energy Factors less than 0.58. REMARKS -- CEC DEFAULT U-VALUES USED. NO FORMS 3R REQUIRED. FRONT: STREET FACING FACADE.(RES.MANUAL P.G-24) FAU UP: BDP#383K036055 53 KBTUH .80 AFUE FAU DN: BDP#383K060090 89 KBTUH .80 AFUE FAU"BSMT.: BDP#383K024035 35 KBTUH .80 AFUE A/C UP: BDP#561A-036 36 KBTUH 10.0 SEER - A/C DN: BDP#561A-060 60 KBTUH 10.0 SEER Im A/C BSMT.: BDP#561A-024 24 KBTUH 10.0 SEER WH: AMERICAN#G52-100T88-3NV 100 GAL. R-16 INT.INSUL. W/RECIRC. HVAC SIZING Page 7 HVAC Project Title HAGUE RESIDENCE Date..09/17/99 09:11:45 Project Address 18 SHORELINE DRIVE ******* NEWPORT BEACH CA. *v5.00* Documentation Author. PAUL KANDARIAN ******* Southland Energy Consultants 1491 Glenneyre Street Laguna Beach, CA 92651 949-497-3591 - Climate Zone 06 Compliance Method MICROPAS5 v5.00 for 1999 Standards Building Permit # Plan Check / Date Field Check/ Date by Enercomp, Inc. MICROPAS5 v5.00 File-HAGUE Wth-CTZ06S92 Program-HVAC SIZING User#-MP0298 User -Southland Energy Consulta Run -NEW RESIDENCE GENERAL INFORMATION Floor Area 5320 sf Volume 53200 cf Front Orientation Front Facing 0 deg (N) Sizing Location NEWPORT BEACH Latitude 33.6 degrees Winter Outside Design 39 F Winter Inside Design 70 F Summer Outside Design 80 F Summer Inside Design 78 F Summer Range 12 F Interior Shading Used No Exterior Shading Used No Overhang Shading Used No Latent Load Fraction 0.20 Description HEATING AND COOLING LOAD SUMMARY Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar 24954 9077 Glazing Conduction 29801 1923 Glazing Solar n/a 49625 Infiltration 21047 542 Internal Gain n/a 2100 Ducts 7580 6327 Sensible Load Latent Load 83382 69594 n/a 13919 Minimum Total Load 83382 83512 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment.