HomeMy WebLinkAboutPRR FIRE`ROJECT REVIEW REQUE:
COMMUNITY DEVELOPMENT DEPARTMENT
Planning Division
Please Distribute to:
Building — Seimone Jurjis
Public Works — Brine/Keely/Cho
Corporate Yard - Pisani
Fire Department - Susan Guzzetta\ Alcaraz
Police Dept - Sgt. J. Lowe/S. Arnold (Traffic)
Parks & Recreation — Sean Levin
Date: September 29, 2014
Please return PRR and Plans to Staff Planner
Rosalinh Unq, Associate Planner
(949) 644-3208, runqnewportbeachca.qov
Applicant:
Newport Place Residential, LLC
Contact:
Britnae Jensen
949 672-8068
bjensen@np-residential.com
Project Name
The Residences at Newport Place
Address:
1701 Corinthian Way, 1660 Dove Street, 4251, 4253, 4255 Martingale Way, 4200, 4220, &
4250 Scott Drive, West of Mac Arthur Boulevard, and bounded by Corinthian Way,
Martingale Drive, Dove Street and Scott Drive
(PA2014-150)
LM2014-003 & PL2014-001
A planned development permit, lot merger, affordable housing implementation plan and mitigated
negative declaration to develop a mixed use, residential project consisting of up to 384 residential
units and 4,315 square feet of retail use on a 5.7-acre property.
REPORT REQUESTED BY:
October 14, 2014
PLANNING COMMISSION HEARING DATE: SELECT DATE
Check all that apply:
❑ No comments on the project
as presented.
❑ Application of Standard Code
requirements are not
expected to alter the project
esign.
Recommended conditions of
approval are attached.
❑ Application of Standard Code
requirements or the attached
conditions of approval will
substantially impact or alter
the design of the project.
❑ I contacted the applicant on
❑ To schedule an appt. for
Code review
❑ To discuss the following
(see notes)
Notes:
S,a7 1017---L1
Ext. Date
Please indicate the approximate time spent on reviewing this project:
Tmplt: 02/09/11
Newport Beach Fire Department
Life Safety Services Division
100 Civic Center Drive
Newport Beach, CA 92658
(949) 644-3107
Planning Commission Project Reviezv
Conditions for Approval
DATE: October 17, 2014
PROJECT LOCATION: 1701 Corinthian Way, 1660 Dove St. 4251, 4253, 4255 Martingale way, 4220 &
4250 Scott Drive
Conditions:
1. All proposed and existing fire hydrants within 400 feet of the project shall be shown on the site plan.
2. Fire flow determination will be required for the proposed buildings. Newport Beach Fire Department
Guideline B.01 "Determination of Required Fire Flow" can be consulted for assistance with fire flow
calculations. The fire flow will need to be included with the plan submittal for the buildings.
3. Fire hydrants are required to be located within 400 feet of all portions of the building. Additional
hydrants may be required dependent on fire flow calculations.
4. Blue hydrant identification markers shall be placed adjacent to fire hydrants.
5. Apparatus access roads must be constructed of a material that provides an all-weather driving surface
and capable of supporting 72,000 pounds imposed load for fire apparatus and truck outrigger loads of 75
pounds per square inch over a two foot area. Calculations stamped and signed by a registered
professional engineer shall certify that the proposed surface meets the criteria of an all-weather driving
surface and is capable of withstanding the weight of 72,000 pounds. Newport Beach Fire Department
Guideline C.01.
6. The proposed fire access on Scott Drive will require calculations and a statement stamped and signed by
registered civil engineer which shall certify that the proposed alternative surface and its substrate meet
the criteria for an all-weather driving surface as specified by the product manufacturer. The engineer
shall also certify that the alternative surface is capable of withstanding the weight requirements as
referenced in comment number 5. The manufactures specification for the product must indicate that the
product is approved for the application or consistent with the manufacturer's recommendations.
Manufacturer's specifications, including details for the required substrate must be included with the
plan. Please consult Newport Beach Fire Department Guideline C.01 for alternative surface
specifications.
7. All security gates (including at entrance to garage and interior of garage area) shall have an approved
remote opening device for emergency services. Consult N.B.F.D. Guideline C.01 for gate requirements.
8. An automatic fire sprinkler system will be required and shall be installed as per C.F.C. Sec. 903.
9. The underground fire line will be reviewed by the fire department. A separate submittal is required
which requires an "F" Permit. The underground fire line is a separate submittal (cannot be part of the
overhead fire sprinkler plans, nor precise or rough grading plans) and must be designed as per N.B.F.D.
Guideline F.04 "Private Hydrants and Sprinkler Supply Line Underground Piping."
10. Standpipes system shall be provided as set forth in C.F.C. Sec. 905. Additional standpipes (due to
access restrictions with design of project) will be required in locations determined by the fire
department.
11. A fire alarm system will be required and shall be installed as per C.F.C. Sec. 907.
12. 2A 10BC Fire Extinguishers will be required for the R-2 Occupancy. This fire extinguisher will cover
3,000 square feet of floor area. The extinguisher must be located so that it is not more than 75 feet
travel distance to reach an extinguisher from the front door of each apartment.
13. The parking garage is classified as an ordinary hazard occupancy which requires a 2A 20BC fire
extinguisher. This fire extinguisher will cover 1500 square feet of floor area and the extinguisher must
be located so that it is not more than 50 feet travel distance to reach an extinguisher from the garage
floor area.
14. Effective emergency responder radio coverage (800 MHz) will be required and shall comply with
Newport Beach Fire Department Guideline & Standards D.05 Public Safety Radio System Coverage.
15. Premises identification shall be provided as City of Newport Beach amended C.F.C. Sec. 505.1.1.
Addresses shall be placed an over or immediately adjacent to all doors that allow fire department access.
In no case shall the numbers be less than four inches in height with a one-half inch stroke.
16. Fire places and fire pit clearance will need to be provided as per manufactures recommendations and/or
California Mechanical Code requirements.
17. All buildings and structures with one of more passenger service elevators shall be provided with not less
than one medical emergency service elevator to all landings. The elevator car shall be of such a size to
accommodate a 24-inch by 84-inch ambulance gurney or stretcher with not less than 5-inch radius
corners, in the horizontal, open position, shall be provided with a minimum clear distance between walls
or between walls and door excluding return panels not less than 80 inches by 54 inches and a minimum
distance from wall to return panel not less than 51 inches with a 42-inch side slide door as per California
Building Code Sec. 3002. Phase I and Phase II recall will be required.
18. Stairwell signage shall meet Newport Beach Fire Department Guideline & Standards D.01.
19. Smoke detectors will be required for the individual dwelling units as per C.F.C. Sec. 907.2.11.1.
20. Dumpster locations will need to meet Newport Beach Fire Department Guideline & Standard A.16.
21. Exterior walkways will need to be designed to accommodate hand carrying of firefighter ladders for use
of "ground" laddering of buildings. (The largest ladder utilized will be 35-foot ladder with a storing
length of 20.5 feet long.)
22. Laddering ground pads will need to be provided for ground laddering and made large enough to
accommodate a 35-foot ladder with a 70° climbing angle. The laddering pads may need to be provided
in the landscaped areas.
23. Exterior walkways will need to be wide enough to accommodate gumeys.
24. Landscape cannot obstruct laddering to buildings.
25. Roof gardens and landscaped roofs shall comply with the requirements of the California Building Code
and the California Fire Code.
26. Car charging shall meet requirements from National Electrical Code 625.5.
27. The emergency generator needs to be filled from the outside of the building via a remote fill pipe in a
location approved by the fire department.
PROJECT REVIEW REQUEST
COMMUNITY DEVELOPMENT DEPARTMENT
Planning Division
Please Distribute to:
Building — Seimone Jurjis
Public Works — Brine/Keely/Cho
Corporate Yard - Pisani
Fire Department - Susan Guzzetta\ Alcaraz
Parks & Recreation — Sean Levin
Date: March 16, 2015
Please return PRR and Plans to Staff Planner
Rosalinh Ung, Associate Planner
(949) 644-3208, runq(a�newportbeachca.gov
Applicant:
Newport Place Residential, LLC
Contact:
Britnae Jensen
949 672-8068
bjensen@np-residential.com
Project Name
The Residences at Newport Place
Address:
1701 Corinthian Way, 1660 Dove Street, 4251, 4253, 4255 Martingale Way, 4200, 4220, 42
Scott Drive, West of Mac Arthur Boulevard, and bounded by Corinthian Way, Martingale Dri
Dove Street and Scott Drive
(PA2014-150)
LM2014-003 & PL2014-001
A planned development permit, lot merger, affordable housing implementation plan and mitigated
negative declaration to develop a mixed use, residential project consisting of up to 384 residential
units and 4,315 square feet of retail use on a 5.7-acre property. 2nd SUBMITTAL
REPORT REQUESTED BY: March 30, 2015
PLANNING COMMISSION HEARING DATE: TBD
Check all that apply:
Notes:
❑ No comments on the project
aA presented.
❑ Applicationationoof Standard Code
requirements are not
expected to alter the project
design.
❑ Recommended conditions of
approval are attached.
❑ Application of Standard Code
requirements or the attached
conditions of approval will
substantially impact or alter
the design of the project.
❑ I contacted the applicant on
cSa Yny -co irk m-) y
{' 1j"' ��t OM e-- P i 4 �1
I �/� y� Ah
�'/ " "� ' , 2I073z0 e) ,
❑ To schedule an appt. for
Code review
❑ To discuss the following
(see notes)
jy' c, L
Signat re Ext. Date
Please indicate the approximate time spent on reviewing this project: 2 t9 v i roi
Tm plt: 02/09/11
Newport Beach Fire Department
Life Safety Services Division
100 Civic Center Drive
Newport Beach, CA 92658
(949) 644-3107
Planning Commission Project Review
Conditions for Approval
DATE: October 17, 2014 — Revised 03-30-15
PROJECT LOCATION: 1701 Corinthian Way, 1660 Dove St. 4251, 4253, 4255 Martingale way, 4220 &
4250 Scott Drive
Conditions:
1. All proposed and existing fire hydrants within 400 feet of the project shall be shown on the site plan.
2. Fire flow determination will be required for the proposed buildings. Newport Beach Fire Department
Guideline B.O1 "Determination of Required Fire Flow" can be consulted for assistance with fire flow
calculations. The fire flow will need to be included with the plan submittal for the buildings.
3. Fire hydrants are required to be located within 400 feet of all portions of the building. Additional
hydrants may be required dependent on fire flow calculations.
4. Blue hydrant identification markers shall be placed adjacent to fire hydrants.
5. Apparatus access roads must be constructed of a material that provides an all-weather driving surface
and capable of supporting 72,000 pounds imposed load for fire apparatus and truck outrigger loads of 75
pounds per square inch over a two foot area. Calculations stamped and signed by a registered
professional engineer shall certify that the proposed surface meets the criteria of an all-weather driving
surface and is capable of withstanding the weight of 72,000 pounds. Newport Beach Fire Department
Guideline C.O1.
6. The proposed fire access on Scott Drive will require calculations and a statement stamped and signed by
registered civil engineer which shall certify that the proposed alternative surface and its substrate meet
the criteria for an all-weather driving surface as specified by the product manufacturer. The engineer
shall also certify that the alternative surface is capable of withstanding the weight requirements as
referenced in comment number 5. The manufactures specification for the product must indicate that the
product is approved for the application or consistent with the manufacturer's recommendations.
Manufacturer's specifications, including details for the required substrate must be included with the
plan. Please consult Newport Beach Fire Department Guideline C.01 for alternative surface
specifications. This access area is to be used exclusively for fire access only, as per the California
Vehicle code fire access cannot be shared for any other use. Access will need to be marked for fire
use only as per Newport Beach Fire Guideline C.O1.
7. All security gates (including at entrance to garage and interior of garage area) shall have an approved
remote opening device for emergency services. Consult N.B.F.D. Guideline C.01 for gate requirements.
8. An automatic fire sprinkler system will be required and shall be installed as per C.F.C. Sec. 903.
9. The underground fire line will be reviewed by the fire department. A separate submittal is required
which requires an "F" Permit. The underground fire line is a separate submittal (cannot be part of the
overhead fire sprinkler plans, nor precise or rough grading plans) and must be designed as per N.B.F.D.
Guideline F.04 "Private Hydrants and Sprinkler Supply Line Underground Piping."
10. Standpipes system shall be provided as set forth in C.F.C. Sec. 905. Additional standpipes (due to
access restrictions with design of project) will be required in locations determined by the fire
department.
11. A fire alarm system will be required and shall be installed as per C.F.C. Sec. 907.
12. 2A 10BC Fire Extinguishers will be required for the R-2 Occupancy. This fire extinguisher will cover
3,000 square feet of floor area. The extinguisher must be located so that it is not more than 75 feet
travel distance to reach an extinguisher from the front door of each apartment.
13. The parking garage is classified as an ordinary hazard occupancy which requires a 2A 20BC fire
extinguisher. This fire extinguisher will cover 1500 square feet of floor area and the extinguisher must
be located so that it is not more than 50 feet travel distance to reach an extinguisher from the garage
floor area.
14. Effective emergency responder radio coverage (800 MHz) will be required and shall comply with
Newport Beach Fire Department Guideline & Standards D.05 Public Safety Radio System Coverage.
15. Premises identification shall be provided as City of Newport Beach amended C.F.C. Sec. 505.1.1.
Addresses shall be placed an over or immediately adjacent to all doors that allow fire department access.
In no case shall the numbers be less than four inches in height with a one-half inch stroke.
16. Fire places and fire pit clearance will need to be provided as per manufactures recommendations and/or
California Mechanical Code requirements.
17. All buildings and structures with one of more passenger service elevators shall be provided with not less
than one medical emergency service elevator to all landings. The elevator car shall be of such a size to
accommodate a 24-inch by 84-inch ambulance gurney or stretcher with not less than 5-inch radius
corners, in the horizontal, open position, shall be provided with a minimum clear distance between walls
or between walls and door excluding return panels not less than 80 inches by 54 inches and a minimum
distance from wall to retum panel not less than 51 inches with a 42-inch side slide door as per California
Building Code Sec. 3002. Phase I and Phase II recall will be required.
18. Stairwell signage shall meet Newport Beach Fire Department Guideline & Standards D.01.
19. Smoke detectors will be required for the individual dwelling units as per C.F.C. Sec. 907.2.11.1.
20. Dumpster locations will need to meet Newport Beach Fire Department Guideline & Standard A.16.
21. Exterior walkways will need to be designed to accommodate hand carrying of firefighter ladders for use
of "ground" laddering of buildings. (The largest ladder utilized will be 35-foot ladder with a storing
length of 20.5 feet long.)
22. Laddering ground pads will need to be provided for ground laddering and made large enough to
accommodate a 35-foot ladder with a 70° climbing angle. The laddering pads may need to be provided
in the landscaped areas.
23. Exterior walkways will need to be wide enough to accommodate gurneys.
24. Landscape cannot obstruct laddering to buildings.
25. Roof gardens and landscaped roofs shall comply with the requirements of the California Building Code
and the California Fire Code.
26. Car charging shall meet requirements from National Electrical Code 625.5.
27. The emergency generator needs to be filled from the outside of the building via a remote fill pipe in a
location approved by the fire department.
PROJECT REVIEW REQUEST
COMMUNITY DEVELOPMENT DEPARTMENT
Planning Division
Please Distribute to:
Building — Seimone Jurjis
Public Works — Brine/Keely/Cho
Fire Department - Susan Guzzettal Alcaraz
Date: May 29, 2015
Please return PRR and Plans to Staff Planner
Rosalinh Unq, Associate Planner
(949) 644-3208, runqanewportbeachca.gov
Applicant:
Newport Place Residential, LLC
Contact:
Britnae Jensen
949 672-8068
bjensen@np-residential.com
Project Name
The Residences at Newport Place
Address:
1701 Corinthian Way, 1660 Dove Street, 4251, 4253, 4255 Martingale Way, 4200, 4220, 42
Scott Drive, West of Mac Arthur Boulevard, and bounded by Corinthian Way, Martingale Dri'
Dove Street and Scott Drive
(PA2014-150)
LM2014-003 & PL2014-001
A planned development permit, lot merger, affordable housing implementation plan and mitigated
negative declaration to develop a mixed use, residential project consisting of up to 384 residential
units and 4,315 square feet of retail use on a 5.7-acre property. and SUBMITTAL
REPORT REQUESTED BY: June 12, 2015
PLANNING COMMISSION HEARING DATE: TBD
Check all that apply:
Notes:
/09
❑ No comments on the project
as presented.
❑ Application of Standard Code
requirements are not
expected to alter the project
design.
❑ Recommended conditions of
approval are attached.
D Application of Standard Code
requirements or the attached
conditions of approval will
substantially impact or alter
the design of the project.
❑ I contacted the applicant on
6 yY) -(4 �l
.)
6 ~,3 "l -!3'
1
1
9 7 Lth.2),447
❑ To schedule an appt. for
Code review
CITo discuss the following
(see notes)
Signature
Ext. Date
Please indicate the approximate time spent on reviewing this project:
Tmplt: 02/09/11