HomeMy WebLinkAboutB9703256 - Alternative Material & Methods4111 CITY OF NEWPORT BEACH BUILDING DEPARTMENT 3300 Newport Boulevard, P.O. Box 1768, Newport Beach, CA 92658-8915 CASE NO. a (Receipt No.) 1 ❑REQUEST FOR MODIFICATION TOPROVISIONS OF TITLE 15 OF THE NEWPORT BEACH MUNICIPAL CODE (See Reverse for Basis for Approval) (Fee$150) x REQUEST FOR ALTERNATE MATERIAL OR METHOD OF CONSTRUCTION (See Reverse for Basis for Approval) (Fee $150) ❑ REQUEST FOR EXEMPTION FROM DISABLED ACCESS DUE TO PHYSICAL OR LEGAL CONSTRAINT (Fee $665) (Ratification by the Board of Appeals will be required.) For above requests, complete Sections 1, 2 & 3 by printing in ink or typing. •• :... •'•'FORSTAFFUSEONLY P1arrCheck # "Qecugdncy:Glass' Use ofBullgingh�:. Projeet Status Construction ' Verified.by' : K" # of Stories; •' ` ' icalion : ' -, +— % ):: #.ofU'nits. �' t t TV S, "r 0419,kr6 "' .« ' NoaofTtems : •r. / tom' f•, '' " ,-Pee,due•' . , •DISTRIB , • ❑.Owner Petgtoner'.. ' iVire, • " •ION:: Cheek „.xnspectar "A id•', ; ', .. . y 5:;,:,Pln • ...L.,. ' ...,.__.,..,,.Othef 1 '1 JOB ADDRESS Site Address: One Hoag Drive Petitioner Address Irvine, �-�-e rr�rr Tsneh y ma & Kninn Owner lio,g Meu,orJai Boari+-01 17877 Vnn Karman Ave., Suite 100 Address 1501 Superior Ave., Suite 310 CA Zip 97614 Newport Beach. CA Zip 92663 Daytime Phone (949 ) 756-0565 Daytime Phone (949 ) 646-8901 21REQUEST: Submit plans if necessary to illustrate request. Additional sheets or data may be attached. Acceptance of 3 inch vent routing as designed on enclosed half—size sheet P 2.04 3 IJUSTIFICATION/FINDINGS OF EQUIVALENCY:. CODE SECTIONS: Please find enclosed letter dated May 13,1999, and vent isometric diagram. In additior the architectural and structural conditions do not allow the vent to rise vertically and terminate near the location of it's origin. If you have any questions. please calf our office. Petitioner's QQ // Signature d1 .4.n "SD Position Senior Associate Date May 14,1999 • DEPARTMENT ACTION: In accordance with 0 105 UAC 0 106 UAC cohcurrence ftonvthe Fire Marshal is required •'DrApprovcd:' Request' .:Request ty: (DOES) (DOES' NOT) 1•essetn aitylire protectlonLrdquieements, (DOES] (DOES=NOTy lessen the structural integrity 'The Granted'' Granted°(Baffication required ' ❑'Disapiiraved ❑-Written Comments Attached;' • DenieipfSee;reverse for aphcaliinformadon) Signature Print Name APPEAL OF DEPARTMENT ACTION TO THE BUILDING BOARD OF APPEALS (See Reverse) Signature, statement of owner or applicant, statement of reasons for appeal and filing fees are required.) Position\L .,, OAln CASHIER VALIDATION MAY 191999 Forms\regmodif1098. doc CITY UrNtwr0tt1 btACH BASIS FOR APPROVAL For the Building Official and Fire Marshal or their designated agent to approve a request for modification or a request for alternate material or method of construction, he/she must determine that special, individual reasons exist that make compliance with thc stnct letter of the Code impractical and that equivalency is provided The resulting condition must be in conformance with the spirit and purpose of' the Code provisions involved and that such modification does not lessen fire protcction, structural integrity or occupant safety The applicant must provide sufficient information with this application to allow thc above evaluation to be made INFORMATION ON PROCEDURE FOR APPEAL FROM A DETERMINATION OR ACTION BY THE BUILDING OFFICIAL OR FIRE MARSHAL Appeal from the determination or action of the Building Official or Fire Marshal or their designated agent may bc made to the Building Board of Appeals To appeal, the applicant must provide special individual reasons that make compliance with the strict letter of the Code impractical. Appeals or ratifications pertaining to State Disabled Access Standards require complete evidence to substantiate that thc proposed design is equivalent to that prescribed by that standards or that due to legal or physical constraints, compliance much the standards or providing equivalency would create an unreasonable hardship. Appeals must be submitted on the Appeal Form mailable at Permit Counter accompanied by the proper fee You will bc notified in IS of the appeal hearing's time and date (This space for supplemental information and/or sketch of job condition) J Date CITY OF NEWPORT BEACH P.O. BOX 1768, NEWPORT BEACH, CA 92658-8915 BUILDING DEPARTMENT - (714) 644-3288 FEE RECEIPTEq S ) 4C-'@ Plan Check No. I el 3 6 Received By: 5 u1 GI '319 A Receive From ono I-i-04% be Job Address Building Plan Check '..G & [fgsiifleaL±I .O..1!1..2900-5002 $ ) Cjp,o6 Zoning Plan Check (Architectural) 2700-5003 $ Zoning Plan Check (Grading) 2700-5003 $ Grading Plan Check - Cu. Yds. 2900-5004 $ Fire Plan Check 2330-5055 $ Electric Plan Check 2900-4612 $ Plumbing Plan Check 2900-4616 $ Mechanical Plan Check 2900-4618 $ Overtime Plan Check - Building 2900-5023 $ Overtime Plan Check - Grading 2900-5004 $ Overtime Plan Check - Planning 2700-5003 $ Preliminary Code Compliance Review 2900-5002 $ Reinspection B E H P/Special Inspection 2900-5008 $ Reinspection Fire 2330-5050 $ Temporary Electric 2900-4612 $ Temporary Gas 2900-4616 $ Temporary Certificate of Occupancy 2900-5008 $ Underground Utilities Waiver 010-2225 $ Grease Interceptor 2900-4620 $ Planning Department Fees 2700-5000 $ Sale of Maps & Publications 2700-5812 $ Determination of Unreasonable Hardship 2900-5018 $ Microfilm Copies/Photocopies 010-2263 $ Other (Specify) $ TOTAL FEES $ I 55 ' Fee Receipt No. NOTICE: PLAN CHECK EXPIRES 180 DAYS FROM DATE OF SUBMITT� ft/999 (f\feercpt.198) 3300 Newport Boulevard, Newport Beach MAY 1 91999 CITY Ur I tvvrun i ntAt t-1 TSUCHIYAMA & KAINO Consulting Mechanical Engineers Principals Victor M. Tsuchlyama, P.E. Kenneth K Koino, P.E. Roger Carter, P.E. Lany Sun, P.E. May 13, 1999 Mr. John Berkley CITY OF NEWPORT BEACH BUILDING DEPARTMENT 3300 Newport Boulevard Newport Beach, CA 92658-8915 Subject: Hoag Memorial Hospital Support Services Building Senior Associate Stanley S Sato Associates Russell D. Gault Don Harrlsberger, P.E. Cinch L Noll Robert J. Scully Tiwan L. Tang, P,E. Dear Mr. Berkley Pursuant to the sanitary vent system, we would like to file a variance to assist the project to continue towards the completion date. Venting System 1. UPC 1994, Section 901.0 states that fixture trap "shall be protected against siphonage and back - pressure and air circulation shall be assured throughout all parts of the drainage system by means of vent pipes". 2. The fixture trap requires an atmospheric pressure of ±1 inch of water column. The vent piping must be designed to permit the air to flow freely without compression or expansion, except for the small amount necessary to overcome friction. 3. The velocity of air flow out of an outlet to the vent pipe outlet is the actual quantity of discharge in GPM and calculated to be 13.17. 4. The static pressure of air is based on the density of water/cu.ft. The density of air in lbs./cu.ft. at a temperature of 70°F. has been calculated to 69.23 ft. of air column. Therefore the rate of discharge from a vent outlet can be determined as 1 inch of water or 69.23 ft. of air. 5. The gallons per minute discharge rate formula at 1 inch water column is as follows: qd = actual quantity of air discharge, GPM. d2o = outlet of vent pipe diameter, inches. hla = Static head of air in ft. of air column. 17877 Von Karman Avenue • Suite 100 • Irvine • California 92614 • (949) 756-0565 • Fax (949) 756-0927 TSUCHIYAMA & KAINO Consulting Mechanical Engineers Mr. John Berkley CITY OF NEWPORT BEACH BUILDING DEPARTMENT May 13, 1999 Page 2 For 2" Vent: qd=13.17d2oh1/2 = 13.17 (2)2(69.23)112 = 13.17 (4)(8.32) = 438.3 GPM air discharge For 3" Vent = 986.1 GPM For 4" Vent = 1753.0 GPM For 5" Vent = 2739.0 GPM 6. Also, as stated under Section 905.01, "vent pipes shall be free from drops or sags," this is omit the accumulation of condensation in the venting system. Your immediate attention Is greatly appreciated. Sincerely, TSUCHIYAM9r& KAINO Stanley Safo, Senior Associate SS/mla GAproJ97197.06611etterSSB51399 • Tsuchiyama & Kaino Consulting Mechanical Engineers Eng'r: J. REED Date: 5-13-99 Job: HOAG SUPPORT SERVICES Title: VENTING DIAGRAM SKT-1 PAGE I OF I TO JANITOR'S SINK IN KITCHEN AREA r,` I / I \�� 2' FRFLR // I >` �, A DRAIN / /� 2' IFRFLRY'� ��< // 31(25F.U.) DRAIN 2' s�q ('1-21 3' (14 FU. / / 0� 4' VENT THRU ROOF STANDDPIIPE Y �2' 1 y �APPROX. 24' „r am �� \ fey k y� r3' (35 F.U.J 4' (123 F J) e `-FLOOR DRAIN `� ` INS v SCALE: NONE A FR LAVS. 3' (80 F.U.)--� >. '/ FR TOILET Y CORE 4' QE: SLOPE VENT PIPING TO FIXTURE TO PREVENT ACCUMULATION OF MOISTURE IN THE VENTING SYSTEM . 17877 Von Korman Ave. • Suite 100• Irvine • California 92614 • (949) 756-0565 • FAX (949) 756-0927 4 + t. Ros.t r°n .P.G..wR..e Ak stt - 8 - ."0,a.U. . .UNy.'� ea& A X. I',.,K/�• d�+ 4.a.Q.lX. ,ilk AM- �, . a.. . ,�.0, 0� e`er Cut gota 61A_ sr-L CONDENSATE DRN TRAP . SEE (TWICA O 0 8.3 0 Q9 9.4 10 ORE SPR. VAL ASS'Y, SEE 5PR STANDPIPE 24-x24' ACCESS SEE INTAKE NORMAL ELEC. RM1 2"FD-1 2"V. ON. (3) N'TP DN. & 2' V ON. METHANE EVACUATION 1 2 FAN RM. 1 63-091 L _ Fc0 F ---1 2'- FIXED I,AIR OAP 2' W. SNITH)3950 UPBEH. A.P.P 10F5 L_-_-J u• FFE=-9. CO ABV. FIR 2 W. DN. ELEVAT MACHINE' ROOM UP =(4) H TP UP E EVATOR OBEY ELMS I[ ELEV. pl ELEV. 02 3' UP TO PLD VESTIBU E IEIE3111 4 -P0 UP & DN. MON 4' SUMP NT & 4' UP TO PLD 3' UP 0 PLO. 4' UP TO PLD. 4' UP TO PLO. 3" UP SOLI H RP 4 c G STORAGE WATER TIGHT SHEETMETAL GRAIN PAN 3' UP TO PLD. 1' IRR UP TO STUB 1' IRR LP 3' UP TO PLO up 10 PLO. 3" UP TO PLWIASSR 0M IN&1 4' UP 10 PLO. 1' IRR STUB C 1' IRR UP & DN. Y_CLO_2 OTC (TW. 3) 46' IRR UP & DN. REFER TO LANDSCAPE SHT. L2.05 FOP DRAIN LOCATIONS STORAGE BICLO CLASSROOM (11331 F.F.E.=-7,0' OFFICE ECM— OPY/ °RAGE OPEN OFFICE GO-NFEREND EFICE OFFICE OFFICE OFFICE HI bAI OFFICE m.1A AuoIO VISUAL. STORAGE aACHIIJR SEE y■■y■■y■■ r, MROOME F/C UNIT lk OOM e YF�Y� V, l T W1 ST0''GE ESTIGULE ID= KITCHEN 2V. ON. PUMP C0N1RD PANEL 4' V. UP I1 1RCL PANEL TO 111URAWD POWER UNIT & DN. BUt. STEEL HYDRIIUUC UNE W/ WRAPPING BELOW SLAB 4' 6E0 UP -Fe HD-) 0 + 18" r' cw UP 4` 50 UP & DN. PARKING \Y ✓/ c' . DISTRIBUR ® UNIT • SD UP TO ED 5 TO DOCK —I A-D «'G OCK LIFT PRONDE RAYONS SERIES LEAK BE 9' AD-6 y IRACETEK 5000 LION SYSTEM A N41E. 1. SUMP VENT PIPINO SHALL BE SCHEDULE 40 BLACK STEEL 111111 THREADED CITDNG& A2 AT NO RARE ARE POCKS IN THE LIGHT COURT ROCK GARDEN TO REST DIRECTLY 014 DRAIN CRAZE. KEY PLAN OFFICE BUILDING PARKING STRUCTURE 0 0 0 0 0 D B�/C% riA %G AA r AV //%// PLAN 0 02 0 0 Kam/wmm2 wme Pm L� ,eo. SECTION Nadel Architects Inc Arohl1eNere LOBO 0 Riney 0r. PleMnB Fouts Floor Interiors L0e Ao09108, CelfoM! 00026 MD. 820/100 Fax 010.828.018e TBWohlyan & I(aino 1 i i consulting MecheNc44 OglneNt Iron Von Wolin Avelup Suite 100 Woe, CA Min PH 19491756415658 FAX 19407560977 REVISIONS /B\ 1/5/GB 1 /30/BB /°\ 5/18/98 /4\ 7/7/90 A7/24/98 / 6\ 13/21/08 A9/30/9B /B\ 11/30/0B II 3/22/99 4/20/9B A HOAG HOSPITAL SUPPORT SERVICES BUILDING HOAG PROJ. NO. 1251.56 ONE HOAG DRIVE BUILDINGS 42 & 44 NEWPORT BEACH, CALIF. OFFICE BUILDING CONFERENCE FLOOR P4 (PARKING) PLAN SEGMENT C SCALE : I/B"=I—OH DRAWING ISSUE DATE NOVEMBER 24, 1997 TNP JOB N0. 97-071 0 ZC4 z O 0 c� 1— z O U 0 L>_ 6 V 0 O O ul oe/.WxO1 MU wine W.RRAL +PPG1Ix0 tram wormy ME Meomx, M']u0Neu91f4 Vpex a ME Mo&01 AND THE 50N[ Mu NM a[ WPUCll. U4➢ 04 018tt06➢ Wnml1 MC WUTRI commit or TIE ARCHITECT. CCLIVIGHT 'NAmi Mamics me' qy, RIGHTS m95ANn. 000r octal: a\oe-07aVaAP2-04 roc CONT. VESTIBULE 1-22J Tn /rltc — 11-051 1N' V. UP CONFERENCE 1-15 V REII. A.0 OFFICE WOMEN F.F.E = 6.5' CORRIDOR 1-01 1 2' W. UP To ro. —J� I /° COFFEE S1 1I16I SOV BEH. AP. BEL. COUNTER n Ls wco u FOR CONT. SEE M' H W CW, 2' W. UP VESTIBULE 1-46J FOR CONT. SEE OR CONT. SEE • • • • • • • • ESTIBULE 1930 11 Nadel Architects Inyc Renmllrelptme IN Fourtrth Floor Interfere Los Angeles, De01onnte 00025 800. 8282100 Fee 810.828.0102 'Tewohly5m8 & Kelno Cmsdew MeeFeNCN rnglreme Won Van Damn Avenue, Suite 100 Irvine, CA 9E614 PH (94e11560565 •F431 (949175609b REVISIONS Al2/10/97 AV\ 1/5/9B /4\ 7/7/98 / '\ 10/9/98 A11/30/BB U 3/22/99 12 4/20/99 n n n A HOAG HOSPffA. SUPPORT SERVVCES BURDONG HOAG PRDJ. N0. 1251,56 ONE HOAG DRIVE BUILDINGS 42 & 44 NEWPORT BEACH, CALIF. i ENLARGED TOILET PLANS CONE & 1ST FLOOR SCALE : 1/4"=1'-0" DRAWING ISSUE DATE NOVEMBER 24, 1997 NNP JOB NO. 97-071 ENLARGED FIRST FLOOR RESTROOM PLAN SCALE 1/4'=P-0' ENLARGED CONFERENCE FLOOR RESTROOM PLAN t 11 SCALE 1/4•=1'-0" P3.O1 SHEET OF z 0 D 1- H z O O 0 LA- V 0 O 0 ALL MI.IIN65 AIM WrvfW MARAAL AAPVRnc,tAn cm,6TryF 1HE 9llpryµ µp VMVaused 6601< or n¢ MO&Cr AND INE SAME MAY NOL ¢ 09000AIUI <MO On 016CLO4➢ MnMIT THE WRIT/EN COOSENT 0! IIIE µcx..IFtt. rNgipMT IIAOFa ARCWrtc31NC' ALL RIGHTS. P£SpMn. E 9e219Z'ot erwuw-01 TAX 408-73 AWATER FILTER •EVERPURE' 0C71-MH MWNTEO ON WALL It READILY ACCESSIBLE - KITCHEN EQUIPMENT CONNECTION SCHEDULE NO. DESCRIPTION IOU ROUGH —IN SIZES & HEIGHTS REMARKS W V CW HW GAS 02 JANITOR'S SINK (SS-2) - 3' 2' R' FURNISHED BY PLUMBER JANITOR'S FAUCET - - - TV +38' IV +36' — CD WORK COUNTER MINK * - - - - - I.W. TO PS. 0 FAUCET - - - +1155 " k' +15" - CS) ICE BINle CD ICE CURER * - - - - I.W.TO F.S. 13 SCULLERY SINK * - - - - - I.W. TO F.S. 14 DISPOSER - +10" 2' k5, - TEE CW FROM ITEM 15 15 FAUCET+15" +15' +15' 0U.C. 015HMAO4INE ■ - - - k0. LW. TO FS. , 26.4 GPH 24 HOT FOOD TABLE * - - - - - I.W. TO F.S. * e CONTRACTOR 70 VERIFY INDRECT WASTE 512E. NOTES: I. REFER m KITCHEN DRAWINGS FOR ENACT ROUGH -IN LOCATIONS AND PLUMBING NOTES. 2. WORK SHALL INCLUDE ALL FINAL CONNECTIONS OF FOOD SERVICE CONNECTIONS OF FODO SERVICE EQUIPMENT, 3, FURNISH AND INSTALL VALUES, TRAPS, STOPS, FITTING; AND VACUUM BREAKERS FOR FOOD SERVICE EQUIPMENT. 4. PLUMBING CONTRACTOR SHALL INSTALL ALL FAUCETS SPECIAL SPRAY, WATER INLETS, MINNG VALVES, SOLENOID VALVES, WASTE VALVES, FLEXIBLE UNES AND QUICK DISCONNECTS MHICH ARE FURNISHED UNDER 1HE FOOD SERVICE EQUIPMENT CONTRACTOR. 5, ALL INDIRECT DRAIN LINES FROM KITCHEN SINKS ON EQUIPMENTS SHALL BE A MINIMUM OF 6 INCHES OFF THE FLOOR AND 1/2 INCH AWAY FROM WALLS. 6, ALL EXPOSED FLOOR SINKS SHALL DE PROVIDED WITH GRATES, 7. N KITCHEN AREAS WHERE PIPES ENTER THROUGH A WALL, CEILING 0R FLOOR, THE OPENING AROUND THE PIPE SHALL BE TIGHTLY SEA1E0. ENLARGED KITCHEN • • SCALE 1/4'-1'-0" FOR O SEE —oot H' 2"� I I V. MO. N'/ SOY FOR 8 W H & CW I f ' FOR 0. SYSTEM. PROVIDE & UNE TO SPIGOT. L --A lW r— H, W CW & 2" W. UP 12-81 1 2" W. DN. r I TOILET TOILET u 12-83 I 2" R0- WC-2 I....,r2' Vq, ON. 4 I r V. UP 1 OFFICE 12-801 r 1 �r I WCo BEl COUNTER 1" HW DN. 2' CW DN. W/ 50V BEH AP BET, COUNTER k" V. DN. 4 WHA )i" FOR CONT SE i i ENLARGED SECOND FLOOR KITCHEN AND RESTROOM PLAN SCALE 1/4'=1'-0' Nadel Architects Inc MFAB9ebYre 1960 B. Bundy 14. PMmhg Four81 Floor IM9Nere Los MDWeo. Gellomla 00026 690, 0242100 Fax 810.828.0162 m COFERENCE 2-30 1 OR CONT. 1417 WHTBD TELE. 2-05 k' V. UP 2' F0-1 ELECT. 2-06 1 WHTB r HW 2'W. UP 2 TO 5K, 113. V. DN 1k' V. UP OFFICE 12-32 I k' 1P Up OFFICE 1 2-33 1 OFFICE 1 2-34 I wlarii1JIL © 0 atak N 1. 3 I I CI r, i►`. U 2 o-L 1 in ©Ir-` Ls IL m, WON N ©DN, 4 12-0 1 Y.'H&CWW/ Mt sovs & A.P. BEL, COUNTER 0 CONFERENCE 44 12-45 OFFICE 12-44 I CORRIDOR OPEN OFFICE 2-41 I 12-01 I ME v Y' H & CW W/ 50VS & P.P. BEL. COUNTER LL L1 k' 0w sale w/ S.O.V. FOR R.D. SYSIELI , PROVIDE SPIGOT & UNE TO REFRIGERATOR ENLARGED SECOND FLOOR RESTROOM PLAN 000000/ STORAGE 2-40 I CL O U I Z REF O 2 TBuchlvama & Kalio Ga,dt6B MM*mIW 3931neers 17077 Van Kamm Avenue, Suite 100 Irvine, CA 92614 PH (94917560565 W FAX 0493756'09D REVISIONS e\ / 12/10/97 n / '\ 1/30/28 / K \ 5/113/98 /^\ 7/7/9B 6A 9/30/88 /7\ 10/R/08 / V \ 11/30/913 /tl\ 1/29/99 /12\ 4/2O/99 A HOAC HOSPITAL SUPPORT SERVOCES 03U&DONC HOAG PROJ. N0. 1251.58 ONE HOA0 DRIVE BUILDINGS 42 & 44 NEWPORT BEACH, CALIF. ENLARGED TOILET PLANS SECOND FLOOR SCALE : 1/4"=8'-0" IDRAWING ISSUE DATE NOVEMBER 24, 1997 TNP JOB NO. 97-071 P30C2 2 SHEET OF z O U D F N Z O 0 0 L 0 U 0 O 133t 1193-731— .0 19996105 ,wo WRITTEN u0mu.t IpPrun,a Hrnnx 93933303 n. m0n9. .wo 000000wm Woo- or mE u0kOO 05e .m. SQL Nov NoT nE ouwOR+m, Y013 an uee1e603 0319313 ne Mu1100 mumR Or 933 .Raiser. CJm11-ir N.m amV mn 111034u Rion w:mvm. OF 99-99F0r016o=673 V WVa-m