Loading...
HomeMy WebLinkAbout04 - Rafail Residence Modification Permit - 1246 Somerset Lane - PA2013-213COMMUNITY DEVELOPMENT DEPARTMENT PLANNING DIVISION 100 Civic Center Drive, P.O. Box 1768, Newport Beach, CA 92658 -8915 (949) 644 -3200 Fax: (949) 644 -3229 www.newportbeachca.gov CITY OF NEWPORT BEACH ZONING ADMINISTRATOR STAFF REPORT November 27, 2013 Agenda Item No. 4: SUBJECT: Rafail Residence Modification Permit - (PA2013 -213) 1246 Somerset Lane Modification Permit No. MD2013 -021 APPLICANT: Sam Rafail PLANNER: Makana Nova, Assistant Planner (949) 644 -3249, mnova @newportbeachca.gov ZONING DISTRICT /GENERAL PLAN • Zone: R -1 -6,000 (Single -Unit Residential) • General Plan: RS -D (Single -Unit Residential) PROJECT SUMMARY A modification permit to allow a 40 percent addition to an existing nonconforming single - family residence where the code limits additions up to 10 percent of the existing gross floor area when the required parking width is not provided. The garage provides a 19- foot -2 -inch width where 20 feet is required. The garage is also nonconforming because it provides a 2- foot -2 -inch side setback and 3- foot -2 -inch rear setback where 6 -foot side and rear setbacks are required. RECOMMENDATION 1) Conduct a public hearing; and 2) Adopt Draft Zoning Administrator Resolution No. _ approving Modification Permit No. MD2013 -021 (Attachment No. ZA 1). 1 Rafail Residence Modification Permit Zoning Administrator November 27, 2013 Page 2 DISCUSSION • The subject property is located within the Mariner's Community. The community is characterized by a mix of single -story and two -story single -unit residences where the adjacent properties are currently single -story. The property is 8,656 square feet (approximately 0.2 acres) in area. • The property is currently developed with a 2,476- square -foot, single -unit residence and 420 - square -foot detached garage built in 1964. An addition to the residence was constructed in 1998 and an interior remodel was completed in 2000. At the time the original residence and garage were constructed, the minimum clear interior dimensions of the two -car garage (19 feet 2 inches wide by 20 feet deep) were compliant with the requirements of the Zoning Code. The garage has not been altered since the time of original construction. • The existing garage is nonconforming because it provides a 19 -foot 2 -inch width where 20 feet is required. The garage is also nonconforming because it provides a 2- foot -2 -inch side yard setack and 3- foot -2 -inch rear yard setback where 6 -foot side and rear yard setbacks are required. The location of the garage also projects into a 5- foot -wide utilities easement along the rear of the property. No alterations are proposed to the garage. • The current Zoning Code requires the minimum clear interior dimensions for a two - garage on lots wider than 40 feet to be 20 feet wide by 20 feet deep. Due to the change in the development standards related to minimum size of garage parking spaces required for lots 40 feet wide or more, the existing two -car garage is legal nonconforming. Additions to the existing residence are limited to 10 percent of the existing structure (Section 20.38.060.2.a and b: Nonconforming Parking — Dimensions or Type of Parking Spaces). A larger addition can be permitted with approval of a Modification Permit (Section 20.52.050). • The proposed 1,175- square -foot second -story addition consists of one new bedroom and a new master suite located above the existing first -floor level. • The clear interior garage spaces provided are adequate to park two vehicles and will not be reduced as a result of the design of the proposed additions. • Pursuant to the Zoning Code (Table 3 -10: Off - Street Parking Requirements), the addition will not result in a single -unit residence over 4,000 square feet of livable area; therefore, a third parking space is not required. • The proposed addition will result in a residence that is comparable in size and scale to other single -unit residences in the neighborhood. The maximum lot coverage for the property is 5,140 square feet (60 percent). Lot coverage would not increase with TmpIt:10 -15 -13 9 Rafail Residence Modification Permit Zoning Administrator November 27, 2013 Page 3 the proposed 2nd story addition. The applicant's proposed addition would create a residence with a total of 4,071 square feet including the garage. The result would be a residence that is comparable in size and scale to other dwellings in the neighborhood. • The alternative would be to require the existing garage to be modified to provide the minimum 20 -foot garage width, which would require alteration and modification of the existing structure above and beyond the current scope of work. A variance would be necessary to encroach into rear year setback and the garage addition would also encroach into the existing utilities easement. The only other alternative is to maintain the existing residence in its current condition. ENVIRONMENTAL REVIEW The project is categorically exempt under Section 15301, of the State CEQA (California Environmental Quality Act) Guidelines - Class 1 (Existing Facilities). This exemption includes additions to the existing structure up to 50 percent of the existing floor area or 2,500 square feet, whichever is less and the proposed scope of work is below these limits. PUBLIC NOTICE Notice of this application was published in the Daily Pilot, mailed to all owners of property within 300 feet of the boundaries of the site (excluding intervening rights -of- way and waterways) including the applicant and posted on the subject property at least 10 days before the scheduled hearing, consistent with the provisions of the Municipal Code. Additionally, the item appeared on the agenda for this meeting, which was posted at City Hall and on the City website. APPEAL PERIOD: An appeal may be filed with the Director of Community Development within 14 days following the date of action. For additional information on filing an appeal, contact the Planning Division at (949) 644 -3200. Prepared by: Ma ana Ova Assistant Planner GRfmkn TmpIt:10 -15 -13 S Attachments TmpIt:10 -15 -13 ZA 1 Draft Resolution ZA 2 Vicinity Map ZA 3 Site Photos ZA 4 Project Plans Rafail Residence Modification Permit Zoning Administrator November 27, 2013 Page 4 21 Attachment No. ZA 1 Draft Resolution 5 0 RESOLUTION NO. ZA2013 -0 ## A RESOLUTION OF THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH APPROVING MODIFICATION PERMIT NO. MD2013 -021 TO ALLOW A 40 PERCENT ADDITION TO AN EXISTING SINGLE - FAMILY RESIDENCE LOCATED AT 1246 SOMERSET LANE (PA2013 -213) THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH HEREBY FINDS AS FOLLOWS: SECTION 1. STATEMENT OF FACTS. 1. An application was filed by Sam Rafail, property owner, with respect to property located at 1246 Somerset Avenue and legally described as Lot 32 of Tract 3032, requesting approval of a modification permit. 2. The applicant proposes a modification permit to allow a 40 percent addition to an existing nonconforming single - family residence where the code limits additions up to 10 percent of the existing gross floor area when the required parking width is not provided. The garage provides a 19- foot -2 -inch width is provided where 20 feet is required. The garage is also nonconforming because it provides a 2- foot -2 -inch side setback and 3- foot -2 -inch rear setback where 6 -foot side and rear setbacks are required. 3. The subject property is located within the R -1 -6,000 (Single Unit Residential) Zoning District and the General Plan Land Use Element category is RS -D (Single Unit Residential Detached). 4. The subject property is not located within the coastal zone. 5. A public hearing was held on November 27, 2013, in the Corona del Mar Conference Room (Bay E -1st Floor) at 100 Civic Center Drive, Newport Beach. A notice of time, place and purpose of the meeting was given in accordance with the Newport Beach Municipal Code. Evidence, both written and oral, was presented to, and considered by, the Zoning Administrator at this meeting. SECTION 2. CALIFORNIA ENVIRONMENTAL QUALITY ACT DETERMINATION. 1. This project has been determined to be categorically exempt under the requirements of the California Environmental Quality Act (CEQA) under Class 1 (Existing Facilities) of the Guidelines for CEQA. 2. This exemption includes additions to the existing structure up to 50 percent of the existing floor area or 2,500 square feet, whichever is less. The proposed scope of work is below these limits. Zoning Administrator Resolution No. ZA2013 -0 ## Paqe 2 of 8 SECTION 3. REQUIRED FINDINGS. In accordance with Section 20.52.050.E (Required Findings, Modification Permits) of the Newport Beach Municipal Code (NBMC), the following findings and facts in support of the findings for a modification permit are set forth: Finding: A. The requested modification will be compatible with existing development in the neighborhood. Facts in Support of Finding: 1. The neighborhood is comprised of a development pattern of one- and two -story single - unit dwellings. The Modification Permit will allow a second -story addition to a one -story single -unit residence within the subdivision. 2. The applicant is proposing a 40 percent addition to the existing structures on the lot. The proposed addition will comply with all of the development standards, including lot coverage, height, and setbacks, and will not intensify or alter the existing nonconformities. 3. The resulting residence will consist of 4,071 square feet (3,651 square feet plus a 420 - square -foot garage). Pursuant to Table 3 -10: Off - Street Parking Requirements of the Zoning Code, it will not require the addition of a third garage parking space since the livable floor area (not including the garage) is less than 4,000 square feet. 4. The proposed addition will result in a residence that is similar in bulk and scale to others in the Mariner's Community. 5. The existing development on the property is a single - family residence. As such, there is no change to the density or intensity under the proposed remodel and addition. Finding: B. The granting of the modification is necessary due to practical difficulties associated with the property and that the strict application of the Zoning Code results in physical hardships that are inconsistent with the purpose and intent of the Zoning Code. Facts in Support of Finding: 1. The residences in this area were constructed with garages and setbacks that were in compliance with the Zoning Code at the time of construction. The Zoning Code requires 6 -foot side setbacks. The lot was permitted to be developed with a single - family residence and detached garage in 1964. Therefore, the structure is considered legal nonconforming. 10 -15 -2013 g Zoning Administrator Resolution No. ZA2013 -0 ## Paqe 3 of 8 2. Although the existing garage does not provide the minimum clear interior dimensions required by the Zoning Code, it does provide two useable garage spaces and, therefore, meets the intent of the Zoning Code by providing adequate parking on the site. Approval of the Modification Permit allows the applicant to continue the use of the existing two -car garage, which has not proven detrimental to the occupants or neighbors. 3. The existing garage provides clear interior dimensions of 19 feet 2 inches in width by 20 feet in depth and its location is conflicting with the existing 5- foot -wide public utilities easements along the northeasterly property line acquired by the public at large for utilities purposes. Given the design of the existing residence and proposed scope of work, bringing the garage into conformance would require a significant expansion in the scope of work. A variance to allow an expansion to the garage would be required to allow encroachments into the rear yard setback. Additionally, the location of the addition would be within the existing 5 -foot utilities easement. 4. The existing and proposed development will comply with the height limit, lot coverage, and residential design criteria as shown on the proposed plans. Finding: C. The granting of the modification is necessary due to the unique physical characteristic(s) of the property and /or structure, and /or characteristics of the use. Facts in Support of Finding: 1. The clear interior dimensions of the existing two -car garage were in compliance with the Zoning Code at the time of original construction. However, as a result of amendments to the Zoning Code, the two -car garage is now substandard in size, and is therefore legal nonconforming. 2. Bringing the existing two -car garage into conformance with the clear interior dimensions required by the current Zoning Code would result in a significant increase in the scope of the project. Since the existing garage provides two useable spaces, the intent of the code is achieved. Finding: D. There are no alternatives to the Modification Permit that could provide similar benefits to the applicant with less potential detriment to surrounding owners and occupants, the neighborhood, or to the general public. Facts in Support of Finding: 1. The alternatives would require that the applicant bring the existing two -car garage into conformance by expanding or relocating the existing garage. An addition in the 10 -15 -2013 9 Zoning Administrator Resolution No. ZA2013 -0 ## Paqe 4 of 8 garages existing location would require a Variance for rear setback encroachments and a request for relief from the requirements limitations of the 5 -foot utility easement. 2. The only other alternative is to maintain the existing residence without constructing the proposed addition. 3. The granting of the Modification Permit would not constitute a special privilege inconsistent with the limitations upon other properties zoned R -1 -6,000 as it allows the property owner to maintain equity with other homes in the Mariner's Community, where similar additions have occurred. The proposed project is consistent with historic development in the neighborhood. 4. Strict compliance with 10 percent addition of the existing gross floor area pursuant to per Section 20.38.060.2.a (Nonconforming Parking) of the Zoning Code significantly limits the ability of the property owner to create a two -story home thereby depriving a substantial property right afforded by other R -1 -6,000 lots in the Mariner's community. Finding E. The granting of the modification would not be detrimental to public health, safety, or welfare to the occupants of the property, nearby properties, the neighborhood, or the City, or result in a change in density or intensity that would be inconsistent with the provisions of this Zoning Code. Fact in SUDDort of Findin 1. Though the minimum clear interior dimensions will be less than the minimum required by the Zoning Code, it provides sufficient area for use as a two -car garage. The size of the spaces has not been detrimental to the occupants of the property, nearby properties, neighborhood, or City. 2. The project will not increase the nonconforming status of the existing structure and will comply with all other provisions of the R -1 -6,000 Zoning District. 3. The side and rear setbacks provide adequate access for emergency personnel 4. The spatial relationships between existing development and the adjacent property suggest that the light, air, and privacy of the abutting home and property will not be negatively affected by the proposed addition. The proposed addition is approximately 24 feet 8.5 inches in height at its highest point. The height is well below the 29 -foot height limit for sloped rooflines. The addition will comply with all applicable development standards. 5. The approval of this Modification Permit is conditioned such that the applicant is required to obtain all necessary permits in accordance with the Building Code and other applicable Codes. The applicant/owner is required to obtain a building permit. The construction will then be inspected prior to final of building permits. 10 -15 -2013 10 Zoning Administrator Resolution No. ZA2013 -0 ## Paqe 5 of 8 SECTION 4. DECISION. NOW, THEREFORE, BE IT RESOLVED: 1. The Zoning Administrator of the City of Newport Beach hereby approves Modification Permit No. MD2013 -021, subject to the conditions set forth in Exhibit A, which is attached hereto and incorporated by reference. 2. This action shall become final and effective 14 days after the adoption of this Resolution unless within such time an appeal is filed with the Community Development Director in accordance with the provisions of Title 20 Planning and Zoning, of the Newport Beach Municipal Code. PASSED, APPROVED AND ADOPTED THIS 271h DAY OF NOVEMBER, 2013. Brenda Wisneski, AICP, Zoning Administrator 10 -15 -2013 4. 11 Zoning Administrator Resolution No. ZA2013 -0 ## Paqe 6 of 8 EXHIBIT "A" CONDITIONS OF APPROVAL PLANNING The development shall be in substantial conformance with the approved site plan, floor plans and building elevations stamped and dated with the date of this approval. (Except as modified by applicable conditions of approval.) 2. Modification Permit No. MD2013 -021 shall expire unless exercised within 24 months from the date of approval as specified in Section 20.54.060 (Time Limits and Extensions) of the Newport Beach Municipal Code, unless an extension is otherwise granted. 3. The project is subject to all applicable City ordinances, policies, and standards, unless specifically waived or modified by the conditions of approval. 4. The applicant shall comply with all federal, state, and local laws. Material violation of any of those laws in connection with the use may be cause for revocation of this Use Permit. 5. The Zoning Administrator may add to or modify the conditions of approval to this Modification Permit or revoke this Modification Permit upon a determination that the operation, which is the subject of this Modification Permit, causes injury, or is detrimental to the health, safety, peace, comfort, or general welfare of the community. 6. A copy of the Resolution, including conditions of approval Exhibit "A" shall be incorporated into the Building Division and field sets of plans prior to issuance of the building permits. 7. Prior to issuance of building permits, the applicant shall submit to the Planning Division an additional copy of the approved architectural plans for inclusion in the Modification Permit file. The plans shall be identical to those approved by all City departments for building permit issuance. The approved copy shall include architectural sheets only and shall be reduced in size to 11 inches by 17 inches. The plans shall accurately depict the elements approved by this Modification Permit and shall highlight the approved elements such that they are readily discernible from other elements of the plans. 8. This approval shall expire and become void unless exercised within 24 months from the actual date of review authority approval, except where an extension of time is approved in compliance with the provisions of Title 20 Planning and Zoning of the Newport Beach Municipal Code. 9. To the fullest extent permitted by law, applicant shall indemnify, defend and hold harmless City, its City Council, its boards and commissions, officials, officers, employees, and agents from and against any and all claims, demands, obligations, damages, 10 -15 -2013 12 Zoning Administrator Resolution No. ZA2013 -0 ## Paqe 7 of 8 actions, causes of action, suits, losses, judgments, fines, penalties, liabilities, costs and expenses (including without limitation, attorney's fees, disbursements and court costs) of every kind and nature whatsoever which may arise from or in any manner relate (directly or indirectly) to City's approval of the Rafail Residence Modification including, but not limited to, the Modification Permit No. MD2013 -021 (PA2013 -213). This indemnification shall include, but not be limited to, damages awarded against the City, if any, costs of suit, attorneys' fees, and other expenses incurred in connection with such claim, action, causes of action, suit or proceeding whether incurred by applicant, City, and /or the parties initiating or bringing such proceeding. The applicant shall indemnify the City for all of City's costs, attorneys' fees, and damages, which City incurs in enforcing the indemnification provisions set forth in this condition. The applicant shall pay to the City upon demand any amount owed to the City pursuant to the indemnification requirements prescribed in this condition. Building Division Conditions 10. The applicant is required to obtain all applicable permits from the City's Building Division and Fire Department. The construction plans must comply with the most recent, City - adopted version of the California Building Code. The construction plans must meet all applicable State Disabilities Access requirements. 11. Prior to the issuance of building permits, the wood shingle roofing shall comply with NBMC 15.04.200 (Amendment to Table 1505.1) and NBMC 15.04.220 (Amendment to Section 1505.1.3). Class A roofing is required for all new construction. When more than 50 percent of the existing roof is modified, the entire roof shall comply with Class A assembly. 12. Prior to the issuance of building permits, the sprinkler system shall be modified to include the entire structure and shall not be limited to the new addition. 13. Prior to the issuance of building permits, the window opening protective and eave projections shall comply with the California Residential Code (CRC). 14. The setback for the existing garage is nonconforming and any new work on the garage shall require the structure to comply with the new code as it relates to fire resistive rating per Section R302 and Table R302.1. Public Works Conditions 15. All improvements shall be constructed as required by Ordinance and the Public Works Department. 16. The applicant shall reconstruct the existing broken and /or otherwise damaged concrete sidewalk panels, curb, and gutter along the Somerset Lane frontage. 10 -15 -2013 13 Zoning Administrator Resolution No. ZA2013 -0 ## Paqe 8 of 8 17. The applicant shall remove the existing concrete between the curb and the sidewalk and replace with new sod or low groundcovers of the type approved by the City throughout the Somerset Lane parkway fronting the development site. 18. A new sewer cleanout shall be installed on the public side of the property line, with a traffic -grade box and cover. 19. An encroachment permit is required for all work activities within the public right -of -way. 20. All improvements shall comply with the City's sight distance requirement. See City Standard 110 -L and Section 20.30.130 (Traffic Safety Visibility Area) of the Zoning Code. 21. In case of damage done to public improvements surrounding the development site by the private construction, additional reconstruction within the public right -of -way shall be required at the discretion of the Public Works Inspector. 22. All on -site drainage shall comply with the latest City Water Quality requirements. 23. The existing street tree shall be protected in place. 24. Prior to the issuance of building permits, the property owner shall obtain letters from utilities companies (Southern California Edison, Time Warner, The Gas Company, and AT &T) acknowledging the existing encroachment. Letters shall be scanned onto project plans. 25. County Sanitation District fees shall be paid prior to the issuance of any building permits. 10 -15 -2013 7 Attachment No. ZA 2 Vicinity Map 15 �i 0 r PAW, PA h r ,v .Ak-tL o F " " lTi N c: r *,A Newport Beach Disclaimer: Every reasonable effort has been made to assure the accuracy of the data provided, however, The City of GI$ Newport Beach and its employees and agents disclaim any and all responsibility from or relating to ��'rogr any results obtained in its use. ° m 0 131 262 _ Imagery: 2009 -2011 photos provided by Eagle Feet Imaging www.eagieaerial.com 10/23/2013 10 Attachment No. ZA 3 Site Photos 17 mi .r f i Attachment No. ZA 4 Project Plans 19 FRAMING NOTES I. ALL BEAMS AND HEADERS TO BE OF," OR BETTER UNLESS NOTED OTHERWISE. D451C DESIGN STRESS fb H30P PSI, 2. ALL JOISTS AND RAFTERS TO BE IF. 4 Oft BETTER, UNLESS NOTED OTHERWISE, BASIC DESIGN 5TRES5 "."60 FBI. 3. 6TUD5 PLATES AND MiSC ROUGH FRAMING TO BE O.F. STANDARD GRADE, 4. ALL WOOD EXPOSED TO WEATHER OE,: EXPOSED DECK, JOISTS, BEAMS, POETS, DEC54IN-9, AND RAILINGS) SHALL BE EITHER PRESSURE TREATED OR CED4R OR REDWOOD MATERIAL. S. ALL WOOD MEMBERS COMING INTO CONTACT WITH CONCRETE, EARTH, OR MASONRY SHALL BE PRE66VRE TREATED PER CDC. 6. PLYWOOD SHEATHING SHALL BE PER NOTES AND 541 WALL SGJEDU,E ON SHEET A -1. T. PROVIDE NAILING AS INDICATED ON SHEET A.2. B, PROVIDE 2' SOLID BLOCKING AT J0151 SUPPORTS AND BEARING PARTITIONS. JOISTS PARALLEL TO AND UNDER PARTITIONS SHALL BE DOUBLED. E. BORED HOLES AT THE ENDS OF JOISTS SHALL NOT EXCEED I' W THE JOISTS DEPTH, HOLES BORED IN JOIST SHALL NOT BE "THIN 2- OF THE TOP OR BOTTOM OF THE JOST, AND THE DIAMETER OF SUCH HOLES SHALL NOT EXCEED 1/3 OF THE DEPTH OF THE JOIST, NOTCHES IN THE TOP OR 307OM OF J0I5T5 SHALL NOT EXCEED 1/6 OF THE DEPTH AND SHALL NOT BE LOCATED IN THE MIDDLE I/3 OF THE SPAN. 10, BORED HOLES IN SNOB SHALL NOT EXCEED 40% OF THE STUD WIDTH, WERE LAFP,BR HOLES ARE REONRED, A DIAMETER OF 60% IS PERMITTED PROVIDING THE STUDS ARE DOUBLED AND NO MORE THAN 2 SUCH DOUBLED STUBS ARE BORED. NOTCHES AND CUTS IN 5TUD5 NOT EXCEEDING 2E% IN DEPTH ARE PERMITTED, ALL EXTERIOR WALLS AND MAIN CR055 -5TUD PARTITIONS SHALL BE EFFECTIVELY AND THOROUGHLY BRACED PER OR. IR PROVIDE FIRE AND DRAFT 6TOP5 PER CEO. ADDITIONAL BLOCKING AND BRACING FOR THE ATTACHMENT OF FIXTURES AND CABINETRY SHALL BE SECURELY ATTACHED TO THE FRAMING WITH AT LEAST 3 -AEI NAILS PER END. FIR-BLOCK STAIRS WITH 2 rc 4 BLOCKING BETWEEN STRINGERS AT TOP AND BOTTOM AND ALONG RUN BETWEEN STUDS, 14. USE APPROPRIATE SmPSON "ST.RONG -TE' CONNECTORS OR EQUAL FOR ALL JOIST, RARER, BEAM, COLUMN AND SIMILAR CONNECTIONS. 15. FASTENERS FOR PRESERVATIVE TREATED AND FIRE TREATED WOOD SHALL BE OF HOT DIPPED ZINC COATED GALVANIZED STEEL, 51I-ICON BRONZE OR COPPER. THE COATING WEIGHTS FOR ZINC COATED F45TBNER5 SHALL BE IN ACCORDANCE WITH ASTM A 153, PROJECT DATA I, OCCUPANCY GROW: R`S`U 2. CONSTRUCTION TYPE: VB FULLY SPRWKLERED 3. STORIES: 2 4. CODES, 2010 CALFORNIA BUILDING CODE (CBC), 2010 CALIFORNIA PLUMBING CODE (CPC). 2810 6AL'FORNIA MECHANICAL CODE (CMO) 2010 CALFORNIA ELECTRICAL CODE (CEG, 2010 CALIFORNIA RESIDENTIAL CODE (CRC) GOIO CALFORNA ENERGY CODE 2010 CALIFORNIA GREEN BUILDING STANDARDS CODE 5. C ERS N4TB /ADDRESS /PHONE NO. SAM RAPAIL 1246 SOMERSET LANE NEWPORT BEACH, CA 92660 (54914&').3564 6. AGENTS NgI}?)AppRE55 /PHONE NO, DENNIS DESILVA 2 ®250 SW ACACIA STREET, SUITE 130 NEWPORT BEACH, CA 52660 (9491261-5402 T STRUCTURAL ENGINEER QOUVIS ENGINEERING .400 CAMPUS ORNE NEWPORT BEACH, CA 52660 (045)T52d612 B. ENERGY CONSULTANT GDUVIS ENGINEERING 4400 CAMPUS : ROUE NEWPORT BEACH, CA 82660 (9/91 T52.1612 DEFERRED S BMITTALB__ I. TRUSS PgceaGE 2, FIRE SPRINKLERS DEFERRAL IF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR APPROVAL W THE BUILDING OFFICIAL. THE REGISTERED DESIGN PROFESSIONAL (ROP) IN RESFONaLE CHARGE SHALL LI5T THE DEFFERED SU51ITTAL5 ON THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL, DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE S'JBMITiED TO THE RDP WHO SHALL REVIEW THEM PRIOR TO FORWARDING THEM TO THE CITY WITH A NOTATION INDICATING THAT THE DOCUMENTS HAVE BEEN REVIEWED AND FOOT POND TO BE IN GENERAL CONFORMANCE TO THE DESIGN OF THE AMILDING. THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THEY HAVE BEEN APPROVED BY THE BUILDING OFFICAL. (CHAPTER 1, DIVISION II, SECTION 1013.4.2 OF THE 2010 CDC) A, , i RI�,CE9VG�i By COMMUNITY OCT 30 JP3 0. DEVELOPMENT Z. Q� - ,/'EWPORl ?IV LOT SIZE. 0561 SF EXISTING HOUSE: 2416 SF. 10391 ACRES) NEW ADDITION: ME SF. OCCUPANCY GROUP: R3 / U TOTAL SF.: 3651 5:. CONSTRUCTION TYPE: VB, EXISTING GARAGE: 420 SF. 5PRiNKLERED REMODELED AREA HISS SF. EXIST, LOT COVERAGE: 40AN NEW LOT COVERAGE: 42.3% SITE FL/4N- SCALE; I'= 20' -m" GRAPHIC SCALE (FEET) RI -E-EL� 0 5 25 50 51 -IEET INDEX A -1 NOTES / SITE PLAN SITE NOTES: I. FINISH GRADE AROUND THE NEW 6TRJCTURE /ADDTIION5 54ALL BE SLOPED AWAY FROM THE BUILDING FOR DRAINAGE PURPOSES. ADJUST EXIST, GRADE AND COUP. FIN15H AS REGO. TO ALLOW MIM. 9' SLOPE AWAY FROM HOUSE AT DOORS 2 TIE ALL NEW ROW DRAINAGE INTO EXISTING SITE 9TORMWATER SYSTEM. CONVEY WATER TO STREET GUTTER WITHOUT EROSION OR FLL' UING OVER U PROPERTY LINE 2) PUBLIC RIGHT -OF -WAY 3) PUBLIC AP-WALK A -2 15T FLOOR PLAN 4-3 ROOF PLAN / 2ND FLOOR PLAN A -4 BUILDING ELEVATIONS 4-5 BUILDING SECTIONS / DETAILS 5N -1 GENERAL NOTES AND REOUIREMENTS SN -2 STRUCTURAL DETAILS AND NOTES 5 -1.1 FOUNDATION PLAN S -1.2 SECOND FLOOR FRAMING PLAN 5 -1.3 ROOF FRAMING PLAN 5D -1 STRUCTURAL FOUNDATION DETAILS SD -2 5TRUCTURAL DETAILS AND NOTE5 51D-3 5TRUCTURAL DETAILS T -24.1 TITLE 24 PA2013 -213 for MD2013 -021 1246 Somerset Lane Sam Rafail R >V" — sn (JF+m a�i Z :np Ww� Qry W U Z LL /0 1-/J Lu cc Q �w rz LL Q rn W O z z J Q Q EL ¢ a W Z W w F co MULTI PURPOSE RFOM ,EXISTING;WALLS AND IT -T �I w (F.SS,, 9D�^ C o2 v I I B k I I I A/J EXISTING WAL1-5 AND FIXTURES TO BE REMOVED (E) LIVING ROOM (E) BEDRO §M (E) PLUMBING / MECHANICAL MECHANICAL AND PLUMBING 5YBMEMS YO BE DESIGN BUILD. PROVIDE HIGH EFFICIENCY GAS POMACE AND A/C SYSTEM. SUPPLY AIR SHALL BE DUCTED OVEwi TO CEILING OR HIGH WALT. REGISTERS IN EACH HABITABLE ROOM ELECTRICAL ELECTRICAL TO BE DESIGN BUILD - COORDINATE ALL RECEPTACLE AND LIGHT LCCATICN9 W/ OWNER BEFORE INSTALLATION. WALL LEC-;END HlaYB EXISTING WALL5 (STUD5 TO REMAIN) O HALF WALLS .... .. —i NEW WALLS (E) !(K(ITCHEN (E) DINING ROOM GENERAL NOTES I. A WATER RE515TIVE VAPOR PERMEABLE BARRIER AT LEAST EQUIVALENT TO 2 LAYERS OF GRADE D PAPER 16 REQUIRED OVER PLYWOOD WHERE CEMENT PLASTER 15 USED ON EXTERIOR WALL5. 2. CORROSION REBBISTANT ELA5HING5 SHALL BE INSTALLED AT ALL OF THE FOLLOWING: A, EXTERIOR WINDOW AND DOOR OPENINGG5 - FLABHING5 AT THESE OPENING5 SHALL EXTEND TO THE SURFACE OF DOE EXTERIOR WALL FINISH OR TO THE WATER RE615TANT BARRIER FOR SUBSEQUENT DRAINAGE B, AT WALL AND ROOF INTERSECTIONS 3. GLAZING IN EXTERIOR DOORS OR WITHIN 40 INCHES OF ANY LOCKING MECHANISM SHALL BE OF Mi-LY- TEMPERED GLA55 OR RATED BURGLARY RESISTANT GLAZING. 4. SAFETY GLAZING 15 REQUIRED TO BE PERMANENTLY MARKED (ETCHED) AS REWIRED BY CRC R3ael S. BASEMENTS, HABITABLE ATTICS AND EVERY SLEEPING ROOM SHALL HAVE A WINDOW OR EXTERIOR DOOR FOR EMERGENCY ESCAPE/ RESCUE. A, SA SE MINIMUM NET CLEAR OPENABLE AREA 15 REWIRED (50 BE ALLOWED ON GROUND FLOOR 6.24" MINIMUM NET CLEAR OPAL HT. 15 REQUIRED. O, 20` MINIMUM NET CLEAR PEN, S. WIDTH B RED D. D. MAXIMUM FINISHED SILL HT. 44' ABOVE FLOOR LEVEL IS REP O. . I (E) GARAGE "s I, ------------ -1 I L a WU _1 I 3'.g• 6. ALL EMERGENCY ESCAPE AND ,FE6CUE OPENINGS SHALL BE MAINTAINED FREE OF ANY OBSTRUCTIONS AND SHALL BE OPERATIONAL FROM THE IN61DE OF THE ROOM WITHOUT THE USE OF KEYS, TOOL 6 OR SPECIAL KNOIWLEDGE. T. THERE MUST BE A LANDING ON FLOOR ON EACH SIDE OF EACH EXTERIOR DOOR. LANDINGS SHALL HAVE A MINIMUM SLOPE OF 2% AND BE MEASURED 36' DEEP V THE WIDTH OF THE DOOR 6. ALL HO5E SCSI MUST HAVE AN APPROVED ANTI SIPHON SACKR-OW PREVEMNTION DEVICE. B A SEDIMENT TRAP SHALL BE INSTALLED ON THE GAS LINE WT,fF DOUBTREAM OF THE GAS APPLIANCE S4MCff VALVE AS CLOSE L. THE INLET OF THE APPLIANCE AS EITHER PRACTICAL. THE SEDIMENT TRAP SHALL BE EITHER T iM CUTLET WITH A CAPPED NIPPLE IN THE BOTTOM OUiIEi OR OTHER RECOGNIZED DEVICE. 10. ALL GLAZING SHALL NAVE A TEMPORARY LABEL TH47 SHALL NOT BE REMOVED UNTIL APPROVED INSPECTION, ALL LABELS ARE TO SHOW THE SHOD U- FACTOR, AIR LEAKAGE AND VID15LE TRANSMITTANCE. II. INSTALLATION CERTIFICATES (CF6R -ENV, CF- 6R-LTG -01, CFdR- MECH)MUST BE PROVIDED TO THE BUILDING iNSPEOTOR DURING CONSTRUCTION, b. INSTALLATION CERTIFICATES, OPERATING INFORMATION, MAINTENANCE INFORMATION AND vENTILAYICN INFORMATION MUST BE ESCAPED TO THE BOLDING OWNER PRIOR TO FINAL INSPECTION, LECcEN® f P05E BIBS Y WATER VALVE (REFRIG) Gl GAS VALVE ,J PIECES ED HIGH EFFICACY CAN LIGHTS rW NEW IB) EXISTING =, 3 -WAY "TOO SWITCH DUPLEX RECEPTACLE "pN SCONCE FIXTURE V 5HOKE DETECTORS, 9D. HARO -WIRED WITH BATTERY BACK -UP GABON MC IDS C o2 DETECTOR/ALARM 5� CEILING FIXTURE F ---------- CLG. MOUNTED FLUORESCENT FIXTURE ELECTRIC ,4L NOTES I. PROVIDE GFOI PROTETED RECEPTACLES OITTSCORS, IN THE BATHROOMS, IN THE GARAGE AND IN THE KITCHEN !WITHIN 6' CE THE 5WK) 2. ANY POINT ALONG A WALL IN A HABITABLE ROOM MOST BE WITHIN 6 -0` OF AN RECEPTACLE. 3. PROVIDE A MM, OF (2) 20 A. SMALL APPLIANCE CIRCUITS FOR THE KITCHEN OWNTER TOP5. SUCH CIRCUIT SHALL HAVE NO OTHER RECEPTAOLES, LOAO5 SHALL BE BALANCED. 41 PROVIDE METAL BOXES FOR ALL 240V. RECEPTACLES 5. PROVIDE METAL OR ONE HOUR RATED BOXES AT WALLS AND CEILIN65 BETWEEN THE GARAGE AND THE HOUSE 6. ALL OUTDOOR RECEPTALCES MUST BE WEATHER RESISTANT T. PROVIDE ONE RECEPTACLE IN HALLWAYS IB OR LONGER 8. RECEPTACLE BOXES FOR CEILING FANS MUST BE LISTED SPECIFICALLY FOR THAT UBE 9, PROVIDE A MINIMUM OF (1) 20 AMP CIRCUIT FOR BATHROOM RECEPTACLE&. SUCH CIRCUIT SHALL HAVE NO OTHER RECEPTACLE5, THIS CIRCUIT MAY SERVE MORE THAN QN, BATHROOM. CEO B0 -03(a) C. BATHROOM EXHAUST FANS WHICH EXHAUST DIRECTLY FROM BATHROOMS MST COMPLY WITH CGSS AS. AND MOST INCLUDE THE FOLLOWING'. A. BE ENERGY STAR COMPLIANT B MUMOBTAT TOUCH -HALL BE READILY ACCE65IBL E. HUMIDISTAT CONTROLS SHALL BE CAPABLE OF AD ISTNENT BETWEEN A RELATIVE HUMIDITY OF 504 YD 50% ELECTRICAL NOTES 1 PROVIDE AROI, PROTECTION FOR ALL IS AND 20 AMP .RANCH CIRCW73 SUPPLYING RECEPTACLES IN DWELLING UNIT FAMILY, DINING, Di PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RED ROOMS. CLOSETS, HALLWAYS, OR SIMILAR ROOME AND AREAS PER CEO SECTION 210,12. R. RECEPTACLES SHALL BE LISTED AS TAMPER- RES16TANT FOR ALL IS AND 20 AMP RECEPTACLES IN DWELLING UNIT 13. FOR ATTICS, UNDER FLOOR SPACES, UTILITY ROOMS, AND SASEr£N16 MERE THE6EE SPACES ARE USED FOR STORAGE OR CONTAINING EOUIFxMT REWIRING SERVICE PROVIDE WORK LIGHT, - WITCH, ANO RECEPTACLE OUTLETS. TWE LIGHTING WTLET SHALL BE PROVIDED AT OR NEAR THE EQUIPMENT REWIRING 5ERVICIR5 , CEO 210]0(3) 14A, ALL LUMINAIRES IN THE KITCHEN SHALL SE HIGH EFFICACY CONTROLLED BY STANDARD SWITCHES, ME. ALL LUNINAIRES IN BATAWBGP , GARAGE6, LAUNDRY ROOM$ AND UTILITY ROOMS (EXCEPT CLOSETS LE55 THAN TO $FJ SHALL BE NA H EFFICACY OR BE INCANDESCENT CONTROLLED BY A MAUNAL-ON OCCUPANT SENSOR OR DINNER 14C. ALL PERMANENT LIGHTING IN OTHER THAN KITCHENS BATHROOMS. GARAGES, LAUNDRY ROOM$, UTILITY ROOMS AND CLOSETS QE. LIVING ROOM 5, DINING ROOMS, BEDROOMS, HALLWAYS, ETCJ SHALL BE HIGH EFROACY CONTROLLE BY A STANDARD 6WTCH OR BE INCANDESCENT CONTROLLED BY A DIMMER SWITCH OR MANUAL -CN OCCUPANCY $E'5OR NO ALL CORBOOR LIGHTING ATTACHED TO THE BUILDING SHALL BE HIGH EFFICACY CONTROLLED BY A STANDARD SWITCH OR SHALL BE INCANDE5CENT CONTROLLED BY A MOTION SENSOR WITH INTEGRATED PHOTOCELL. HE, NON -HIGH EFFICACY LUMINAIRES SHALL BE SWITCHED ON A SEPARATE CIRCUIT FROM HWH EFFICACY LUMINAIRES 14F, NIGH- ETOACY LAMPS SHALL PROVIDE THE FOLLOWING EFFICACY: LAMP POWER 5 WATT OR LEBB SHALL PROVIDE 30 LU icN6N1ATT EFFIOACYe LANE POWER 5 i0 15 WATTS SHALL PROVIDE 40 LUMENMATi LAMP EFFICACY[ LAMP POWER 15 TO 40 WATTS 6-ALL PROVIDE 50 LUNE ATT EFFICACY! LAMP POWER MORE THAN 40 WATTS SHALL PROVIDE 60 LUMEN /WATT EFFICACY. 64L1-46i WATTAGE IS NOT INCLUDED WHEN OETERMIIJNG LAMP EFFICACY, 14G. OCCUPANCY 5EN60R5 MUST HAVE NO MANUAL OVERRIDE, 30 MINUTE MAXTI..UM TIMER AND BE MICROWAVENLTRASOMO OR PA65I VE INFRA -RED TYPE, G. HIGH EFICACY LUMINAIRES MUST BE PI@ BASED 16. RECE66ED LIGHTINS FIXTURES ON INSULATED CEILINGS MUST BE LISTED AS ATAD AND 69ALL BE SEALED AND /OR CONTAIN A GASKET 11. PENDANT FIXTURES AND PANEL BOARDS ARE NOT ALLOWED IN 6TO.RAGE CLOSETS 18 ELECTRICAL EWIpMENT MUST BE LISTED BY AN APPROVED TE6TING LAB li MORE DETECTORS AND CO2 DETECTORS MUST BE INSTALLED PER THE FOLLOWING A. 5MCKE DETECTORS AND CO2 DETECTORS MUST BE HARD WIRED WITH BATTERY BACKUP. B. EXISTING CONSTRUCTION MUST BE UPDATED WITH SMOKE DETECTORS (BATTERY OPERATED DETECTORS ARE ADEQUATE MEN' AREA5 ARE NOT ACCESEIBLE) C. SMOKE DETECTORS MUST BE INS A LED IN THE FOLLOWING LOCATIONS: U ONSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS, 2) T ON THE DEALING ABOVE E QUEEN SLEEPING ROOM AN UP S ARE ON AN UPPER LEVEL. 9) IN EACH SLEEPING 4) ON EACH FLOOR INCLUDING BASEMENTS AND HABITABLE ATTICS. D. SMOKE DETECTORS ARE NOT E BE LOCATED A DO IN THE KITCHEN, GARAGE BATHROOM WITHIN 3 FEET FROM E DOOR TO A KITCHEN OR COOLIN S ST SUPPLY AIR REGISTER OF A HEATING OR COOLING SYSTEM. 20. FOR NOW CONSTRUCTION, AN APPROVED CARBON MONOXIDE (CO2) ALARM MUST BE INSTALLED W DWELLING UNITS AND IN SLEEPING UNITS WITHIN WHICH FUEL BURNING APPLIANCES ARE E INSTALLED AND IN DILELLNG UNITS THAT HAVE AT TAC HED GARAGES, 21. FOR NEW CONSTRUCTION REQUIRED CARBON MONOXIDE (CO2) ALARMS SHALL RECEIVE THEIR PRIMARY FOWER FROM THE BUILDING WIRING WHERE SUCH WIRING IS SERVED FROM A COMMERCIAL SOURCE AND SHALL BE EQUIPPED WITH A BATTERY BACKUP, ALARM WIRING BHALL BE DIRECTLY CONNECTED TO THE PERMANENT BUILDING WIRING WITHOUT A DISCONNECTING SWITCH OTHER NAN AS REWIREC FOR OVERCURRENi PROTECTION, 22, IN EXISTING DWELLING UNITS A CARBON MONOXIDE (CO) ALARM IS PERMITTED 70 BE SOLELY BATTERY OPERATED WHERE REPAIRS OR ALTERATIONS DO NOT RESULT IN THE REMOVAL OF WALL AND CEILING FINISHED OR THERE 15 NO ACCESS BY MEANS OF ATTIC, BASEMENT OR CRAW. SPACE, 23, ALL ELECTRICAL CONDUCTORS USED TO CARRY CURRENT SHALL BE COPPER, ALUMIMIM 15 NOT PERMITTED. REVISIONS °£1 �� s o�0 W'e Jwa��4 Q< 1 :, C °n vEP.. Z W V/ �W/y LL fD 11Q1I �Z I.J. IJ. Z Q J a Q O O J LL LL zz A�A I I - " "" I •' I I I I (E) BEDROQM rE)G6D ¢)1660 IEO..60 - (EMBeE6 B uC US� FIX FIX F, DOORS FR DOORS 13 r SIM (E) BEDRO §M (E) PLUMBING / MECHANICAL MECHANICAL AND PLUMBING 5YBMEMS YO BE DESIGN BUILD. PROVIDE HIGH EFFICIENCY GAS POMACE AND A/C SYSTEM. SUPPLY AIR SHALL BE DUCTED OVEwi TO CEILING OR HIGH WALT. REGISTERS IN EACH HABITABLE ROOM ELECTRICAL ELECTRICAL TO BE DESIGN BUILD - COORDINATE ALL RECEPTACLE AND LIGHT LCCATICN9 W/ OWNER BEFORE INSTALLATION. WALL LEC-;END HlaYB EXISTING WALL5 (STUD5 TO REMAIN) O HALF WALLS .... .. —i NEW WALLS (E) !(K(ITCHEN (E) DINING ROOM GENERAL NOTES I. A WATER RE515TIVE VAPOR PERMEABLE BARRIER AT LEAST EQUIVALENT TO 2 LAYERS OF GRADE D PAPER 16 REQUIRED OVER PLYWOOD WHERE CEMENT PLASTER 15 USED ON EXTERIOR WALL5. 2. CORROSION REBBISTANT ELA5HING5 SHALL BE INSTALLED AT ALL OF THE FOLLOWING: A, EXTERIOR WINDOW AND DOOR OPENINGG5 - FLABHING5 AT THESE OPENING5 SHALL EXTEND TO THE SURFACE OF DOE EXTERIOR WALL FINISH OR TO THE WATER RE615TANT BARRIER FOR SUBSEQUENT DRAINAGE B, AT WALL AND ROOF INTERSECTIONS 3. GLAZING IN EXTERIOR DOORS OR WITHIN 40 INCHES OF ANY LOCKING MECHANISM SHALL BE OF Mi-LY- TEMPERED GLA55 OR RATED BURGLARY RESISTANT GLAZING. 4. SAFETY GLAZING 15 REQUIRED TO BE PERMANENTLY MARKED (ETCHED) AS REWIRED BY CRC R3ael S. BASEMENTS, HABITABLE ATTICS AND EVERY SLEEPING ROOM SHALL HAVE A WINDOW OR EXTERIOR DOOR FOR EMERGENCY ESCAPE/ RESCUE. A, SA SE MINIMUM NET CLEAR OPENABLE AREA 15 REWIRED (50 BE ALLOWED ON GROUND FLOOR 6.24" MINIMUM NET CLEAR OPAL HT. 15 REQUIRED. O, 20` MINIMUM NET CLEAR PEN, S. WIDTH B RED D. D. MAXIMUM FINISHED SILL HT. 44' ABOVE FLOOR LEVEL IS REP O. . I (E) GARAGE "s I, ------------ -1 I L a WU _1 I 3'.g• 6. ALL EMERGENCY ESCAPE AND ,FE6CUE OPENINGS SHALL BE MAINTAINED FREE OF ANY OBSTRUCTIONS AND SHALL BE OPERATIONAL FROM THE IN61DE OF THE ROOM WITHOUT THE USE OF KEYS, TOOL 6 OR SPECIAL KNOIWLEDGE. T. THERE MUST BE A LANDING ON FLOOR ON EACH SIDE OF EACH EXTERIOR DOOR. LANDINGS SHALL HAVE A MINIMUM SLOPE OF 2% AND BE MEASURED 36' DEEP V THE WIDTH OF THE DOOR 6. ALL HO5E SCSI MUST HAVE AN APPROVED ANTI SIPHON SACKR-OW PREVEMNTION DEVICE. B A SEDIMENT TRAP SHALL BE INSTALLED ON THE GAS LINE WT,fF DOUBTREAM OF THE GAS APPLIANCE S4MCff VALVE AS CLOSE L. THE INLET OF THE APPLIANCE AS EITHER PRACTICAL. THE SEDIMENT TRAP SHALL BE EITHER T iM CUTLET WITH A CAPPED NIPPLE IN THE BOTTOM OUiIEi OR OTHER RECOGNIZED DEVICE. 10. ALL GLAZING SHALL NAVE A TEMPORARY LABEL TH47 SHALL NOT BE REMOVED UNTIL APPROVED INSPECTION, ALL LABELS ARE TO SHOW THE SHOD U- FACTOR, AIR LEAKAGE AND VID15LE TRANSMITTANCE. II. INSTALLATION CERTIFICATES (CF6R -ENV, CF- 6R-LTG -01, CFdR- MECH)MUST BE PROVIDED TO THE BUILDING iNSPEOTOR DURING CONSTRUCTION, b. INSTALLATION CERTIFICATES, OPERATING INFORMATION, MAINTENANCE INFORMATION AND vENTILAYICN INFORMATION MUST BE ESCAPED TO THE BOLDING OWNER PRIOR TO FINAL INSPECTION, LECcEN® f P05E BIBS Y WATER VALVE (REFRIG) Gl GAS VALVE ,J PIECES ED HIGH EFFICACY CAN LIGHTS rW NEW IB) EXISTING =, 3 -WAY "TOO SWITCH DUPLEX RECEPTACLE "pN SCONCE FIXTURE V 5HOKE DETECTORS, 9D. HARO -WIRED WITH BATTERY BACK -UP GABON MC IDS C o2 DETECTOR/ALARM 5� CEILING FIXTURE F ---------- CLG. MOUNTED FLUORESCENT FIXTURE ELECTRIC ,4L NOTES I. PROVIDE GFOI PROTETED RECEPTACLES OITTSCORS, IN THE BATHROOMS, IN THE GARAGE AND IN THE KITCHEN !WITHIN 6' CE THE 5WK) 2. ANY POINT ALONG A WALL IN A HABITABLE ROOM MOST BE WITHIN 6 -0` OF AN RECEPTACLE. 3. PROVIDE A MM, OF (2) 20 A. SMALL APPLIANCE CIRCUITS FOR THE KITCHEN OWNTER TOP5. SUCH CIRCUIT SHALL HAVE NO OTHER RECEPTAOLES, LOAO5 SHALL BE BALANCED. 41 PROVIDE METAL BOXES FOR ALL 240V. RECEPTACLES 5. PROVIDE METAL OR ONE HOUR RATED BOXES AT WALLS AND CEILIN65 BETWEEN THE GARAGE AND THE HOUSE 6. ALL OUTDOOR RECEPTALCES MUST BE WEATHER RESISTANT T. PROVIDE ONE RECEPTACLE IN HALLWAYS IB OR LONGER 8. RECEPTACLE BOXES FOR CEILING FANS MUST BE LISTED SPECIFICALLY FOR THAT UBE 9, PROVIDE A MINIMUM OF (1) 20 AMP CIRCUIT FOR BATHROOM RECEPTACLE&. SUCH CIRCUIT SHALL HAVE NO OTHER RECEPTACLE5, THIS CIRCUIT MAY SERVE MORE THAN QN, BATHROOM. CEO B0 -03(a) C. BATHROOM EXHAUST FANS WHICH EXHAUST DIRECTLY FROM BATHROOMS MST COMPLY WITH CGSS AS. AND MOST INCLUDE THE FOLLOWING'. A. BE ENERGY STAR COMPLIANT B MUMOBTAT TOUCH -HALL BE READILY ACCE65IBL E. HUMIDISTAT CONTROLS SHALL BE CAPABLE OF AD ISTNENT BETWEEN A RELATIVE HUMIDITY OF 504 YD 50% ELECTRICAL NOTES 1 PROVIDE AROI, PROTECTION FOR ALL IS AND 20 AMP .RANCH CIRCW73 SUPPLYING RECEPTACLES IN DWELLING UNIT FAMILY, DINING, Di PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RED ROOMS. CLOSETS, HALLWAYS, OR SIMILAR ROOME AND AREAS PER CEO SECTION 210,12. R. RECEPTACLES SHALL BE LISTED AS TAMPER- RES16TANT FOR ALL IS AND 20 AMP RECEPTACLES IN DWELLING UNIT 13. FOR ATTICS, UNDER FLOOR SPACES, UTILITY ROOMS, AND SASEr£N16 MERE THE6EE SPACES ARE USED FOR STORAGE OR CONTAINING EOUIFxMT REWIRING SERVICE PROVIDE WORK LIGHT, - WITCH, ANO RECEPTACLE OUTLETS. TWE LIGHTING WTLET SHALL BE PROVIDED AT OR NEAR THE EQUIPMENT REWIRING 5ERVICIR5 , CEO 210]0(3) 14A, ALL LUMINAIRES IN THE KITCHEN SHALL SE HIGH EFFICACY CONTROLLED BY STANDARD SWITCHES, ME. ALL LUNINAIRES IN BATAWBGP , GARAGE6, LAUNDRY ROOM$ AND UTILITY ROOMS (EXCEPT CLOSETS LE55 THAN TO $FJ SHALL BE NA H EFFICACY OR BE INCANDESCENT CONTROLLED BY A MAUNAL-ON OCCUPANT SENSOR OR DINNER 14C. ALL PERMANENT LIGHTING IN OTHER THAN KITCHENS BATHROOMS. GARAGES, LAUNDRY ROOM$, UTILITY ROOMS AND CLOSETS QE. LIVING ROOM 5, DINING ROOMS, BEDROOMS, HALLWAYS, ETCJ SHALL BE HIGH EFROACY CONTROLLE BY A STANDARD 6WTCH OR BE INCANDESCENT CONTROLLED BY A DIMMER SWITCH OR MANUAL -CN OCCUPANCY $E'5OR NO ALL CORBOOR LIGHTING ATTACHED TO THE BUILDING SHALL BE HIGH EFFICACY CONTROLLED BY A STANDARD SWITCH OR SHALL BE INCANDE5CENT CONTROLLED BY A MOTION SENSOR WITH INTEGRATED PHOTOCELL. HE, NON -HIGH EFFICACY LUMINAIRES SHALL BE SWITCHED ON A SEPARATE CIRCUIT FROM HWH EFFICACY LUMINAIRES 14F, NIGH- ETOACY LAMPS SHALL PROVIDE THE FOLLOWING EFFICACY: LAMP POWER 5 WATT OR LEBB SHALL PROVIDE 30 LU icN6N1ATT EFFIOACYe LANE POWER 5 i0 15 WATTS SHALL PROVIDE 40 LUMENMATi LAMP EFFICACY[ LAMP POWER 15 TO 40 WATTS 6-ALL PROVIDE 50 LUNE ATT EFFICACY! LAMP POWER MORE THAN 40 WATTS SHALL PROVIDE 60 LUMEN /WATT EFFICACY. 64L1-46i WATTAGE IS NOT INCLUDED WHEN OETERMIIJNG LAMP EFFICACY, 14G. OCCUPANCY 5EN60R5 MUST HAVE NO MANUAL OVERRIDE, 30 MINUTE MAXTI..UM TIMER AND BE MICROWAVENLTRASOMO OR PA65I VE INFRA -RED TYPE, G. HIGH EFICACY LUMINAIRES MUST BE PI@ BASED 16. RECE66ED LIGHTINS FIXTURES ON INSULATED CEILINGS MUST BE LISTED AS ATAD AND 69ALL BE SEALED AND /OR CONTAIN A GASKET 11. PENDANT FIXTURES AND PANEL BOARDS ARE NOT ALLOWED IN 6TO.RAGE CLOSETS 18 ELECTRICAL EWIpMENT MUST BE LISTED BY AN APPROVED TE6TING LAB li MORE DETECTORS AND CO2 DETECTORS MUST BE INSTALLED PER THE FOLLOWING A. 5MCKE DETECTORS AND CO2 DETECTORS MUST BE HARD WIRED WITH BATTERY BACKUP. B. EXISTING CONSTRUCTION MUST BE UPDATED WITH SMOKE DETECTORS (BATTERY OPERATED DETECTORS ARE ADEQUATE MEN' AREA5 ARE NOT ACCESEIBLE) C. SMOKE DETECTORS MUST BE INS A LED IN THE FOLLOWING LOCATIONS: U ONSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS, 2) T ON THE DEALING ABOVE E QUEEN SLEEPING ROOM AN UP S ARE ON AN UPPER LEVEL. 9) IN EACH SLEEPING 4) ON EACH FLOOR INCLUDING BASEMENTS AND HABITABLE ATTICS. D. SMOKE DETECTORS ARE NOT E BE LOCATED A DO IN THE KITCHEN, GARAGE BATHROOM WITHIN 3 FEET FROM E DOOR TO A KITCHEN OR COOLIN S ST SUPPLY AIR REGISTER OF A HEATING OR COOLING SYSTEM. 20. FOR NOW CONSTRUCTION, AN APPROVED CARBON MONOXIDE (CO2) ALARM MUST BE INSTALLED W DWELLING UNITS AND IN SLEEPING UNITS WITHIN WHICH FUEL BURNING APPLIANCES ARE E INSTALLED AND IN DILELLNG UNITS THAT HAVE AT TAC HED GARAGES, 21. FOR NEW CONSTRUCTION REQUIRED CARBON MONOXIDE (CO2) ALARMS SHALL RECEIVE THEIR PRIMARY FOWER FROM THE BUILDING WIRING WHERE SUCH WIRING IS SERVED FROM A COMMERCIAL SOURCE AND SHALL BE EQUIPPED WITH A BATTERY BACKUP, ALARM WIRING BHALL BE DIRECTLY CONNECTED TO THE PERMANENT BUILDING WIRING WITHOUT A DISCONNECTING SWITCH OTHER NAN AS REWIREC FOR OVERCURRENi PROTECTION, 22, IN EXISTING DWELLING UNITS A CARBON MONOXIDE (CO) ALARM IS PERMITTED 70 BE SOLELY BATTERY OPERATED WHERE REPAIRS OR ALTERATIONS DO NOT RESULT IN THE REMOVAL OF WALL AND CEILING FINISHED OR THERE 15 NO ACCESS BY MEANS OF ATTIC, BASEMENT OR CRAW. SPACE, 23, ALL ELECTRICAL CONDUCTORS USED TO CARRY CURRENT SHALL BE COPPER, ALUMIMIM 15 NOT PERMITTED. REVISIONS °£1 �� s o�0 W'e Jwa��4 Q< 1 :, C °n vEP.. Z W V/ �W/y LL fD 11Q1I �Z I.J. IJ. Z Q J a Q O O J LL LL zz A�A I t `—FIRE RETARDANT TREATED WOOD 5:12 SHAKE RDOF TO MATCH EXISTING 5:12 " J r -- I 5:12 N' I `FIRE RETARDANT TREATED WOOD SHAKE ROOF i0 MATCH EXISTING 5:12 5:12 f I I ROOF VENTILATION B NOTE: TYPICAL EXTERIOR WALLS ARE 2x4b m I6" O.C. W/ R -13 BAii W51R.ATION OPERABLE PORTION OF WINDOW SHALL BE MIN. 20" CLEAR WIDTH AND AT LEAST A 5l SF. CL_ °AR UPPER ROOF AREA: Ilya 5F x 144 - 111360 31 ROOF VENTILATION REWIRED: 111360 61/300 - 51] 51 GAVE VENTILATION' RIDDIRED: 5l2 SIR - 286 51 WINDER ROOF RIDGE VENTILATION RE WIREP: 512 WD : 26A R SAVE VENTILATION PROVIDED: 314 BI PER It - 2'e VENT SETH SEA. RAFTER/ TRIES) -152 LF OF SAVE VENTE 152 x W4 . 477 V LEAST A 5.1 S.F. CLEAR UPPER ROOF RIDGE VENTILATION PROVIDED: 1 BEDROOM' 20 OF RIDGE VENT AT R $1 PER FT TOTAL UPPER ROOF VEMILATION - \ 6:f0• \ 2Dx10-36 ®5.I. ROOF PLAN 5CALE: 1/4" = I' -O" —EMT A l' -5 1/T I� STORAGE Q �.�. PR / SpO BEDROOMi j I V I CEILING REVISIONS / I RIDGE 4 3E MIN, 20` CLEAR WIDTH _A. FJREPLA MASTER LEAST A 5.1 S.F. CLEAR 1 BEDROOM' 1\ AS9EMBL 4'101/2" 1.9• \ 6:f0• \ I 2 ®eB 06 I I `SI @ MASTR ?a X (BATH' c�G iil II ® lo� EA l' -5 1/T I� STORAGE Q �.�. PR / SpO BEDROOMi CTE +j F.RT PLYWOOD PLATFORMS ON yv Lak i FF BOii OM CHORD OF TSRSEE5 FOR LOCATICN OF NEW FAU. RATED FORa� WSidLLATION. INSTALL FER D" MFGR5 INSTRUCTIONS. g PROVIDE LIGHT AND BATCH FOR _ PLAIROR'I. 50O J 9 Ir m EDGE OF EXISDi • RO . BELOW (j :Rw � < HALL -VG CL LS ]T — . - -�" _ NEW FO.OD'ATTIC J o ° g6$ 4--o" W K W •. \ _ _ _ dCCE85 _ T ¢m gPvm /.: e H E _ axG wALy � 24' WIDE FRi, PLYIWJOp 2 v PLATFORM ON BOTTOM CHORD wnvue.w.. �3SDO 42" HIGH �- _ OF FDR15 FOR ACCESS O (� /WALL ry RAU. PLATFORM \C o1 E' RECESS _ _ 9 LA'JNDR TYPICAL STAIRS: CHU TE (IS)l]' RISERS • —..... __r C AND 10' TREADS WITH 36' HIGH WOOD HANOR41L5 4' 3' =6114' 3' -e I14" C I\ 42' NIGH WALL W ROCF LINE ABOVE DEL n F — — J PLUMBING / MECHANICAL MECHANICAL AND PLUMBING SYSMEMS iO 5E DESIGN BUILD. PROVIDE HIGH EFFICIENCY GAS FURNACE AND A/C SYSTEM, IR SUPPLY A SHALL BE DUCTED -II I/2" OVERHEAD TO CEILING OR HIGH I WALL REGISTERS IN EACH HABITABLE .¢GPM I I ELECTRICAL ELECTRICAL i0 BE DESIGN BUILD RECEPTACLE - CLEA AND ALL RECEPTACLE AND LIGHT LOCATIONS W/ OWNER BEFORE INSTALLATION SEE ELECTRICAL NOTES IX,I I 5H'cEi 42 I ' I A SECOND FLOOR PLAN 5CALE: 1 /4 " =1' -O" W W Q ZU Q VJ W Q W ¢m fr 00 J � �3 Q aW 11 NZ J- MQ I..L Z Q J a 1 cr 0 LL O I 0 I Z 0 U W i WALL LEGEND EEJ' EXISTING WALLS (STUDS i0 REMAIN) C� HALF WALLS NEW WALL5 I q� I ' eZ2 REVISIONS 3LE PORTION OF WNDOW 3E MIN, 20` CLEAR WIDTH LEAST A 5.1 S.F. CLEAR 0- �� I I EA DEL n F — — J PLUMBING / MECHANICAL MECHANICAL AND PLUMBING SYSMEMS iO 5E DESIGN BUILD. PROVIDE HIGH EFFICIENCY GAS FURNACE AND A/C SYSTEM, IR SUPPLY A SHALL BE DUCTED -II I/2" OVERHEAD TO CEILING OR HIGH I WALL REGISTERS IN EACH HABITABLE .¢GPM I I ELECTRICAL ELECTRICAL i0 BE DESIGN BUILD RECEPTACLE - CLEA AND ALL RECEPTACLE AND LIGHT LOCATIONS W/ OWNER BEFORE INSTALLATION SEE ELECTRICAL NOTES IX,I I 5H'cEi 42 I ' I A SECOND FLOOR PLAN 5CALE: 1 /4 " =1' -O" W W Q ZU Q VJ W Q W ¢m fr 00 J � �3 Q aW 11 NZ J- MQ I..L Z Q J a 1 cr 0 LL O I 0 I Z 0 U W i WALL LEGEND EEJ' EXISTING WALLS (STUDS i0 REMAIN) C� HALF WALLS NEW WALL5 I q� I ' eZ2 WALL LEGEND EEJ' EXISTING WALLS (STUDS i0 REMAIN) C� HALF WALLS NEW WALL5 I q� I ' eZ2 I � PLP I _ rl 0 FIN_ i — ANT TREATED ROOF TO MATCH almilllllllllllll i 11 All FRONT ELEVATION CEMENT PLASTER SYSTEM TO MATCH EXISTING IWOD WINPCWS TO MATCH EXISTIN5 ® L{{ Ifi I6 I J� CEMENT P1,A5TER SYSTEM TO MATCH EXISTING SIDE ELEVATION 51DE ELEVATION FIRE RETARPAW TREATED HOOD SHAKE ROOF TO MATCH REVISIONS c�Hs� s R I U 5$ Q r a E JU saWP L/ u�P°Jm Ott N$ ba15 4 °ry T ODD WNDOWS O W ATOH EXISTING V Z PLATS W W Q 2U CEMENT PLASTER SYSTEM TO MATCH ExISiING— � _i VJ W Q W ��� N W Lp r O Q Q" W NZ cr Lm - WI I � �I �i Fltt FLR REAR ELEVATION U Z 00 z� oa J_ 7 m J m W i i 2AS GOOD FACIA -"" TYPICAL EXT. WALL CEMENT P1.45TER SYSTEM OVER 3/5" COX PLYWD. OVER zx- STUDS AT I.- OG. W/ R -03 BATT INSULATION — WOOD FLOOR J015T5 SEE STRUCT. DIGS.- RIDGE vENi DCOD SHAKES 70 MATCH EXIST. ROOFIIY OVER 30, CLOG PAPER OVER PLYWOOD zrc RAFT -eR9 PER ROOF DECK - SEE STRUCT. STRT.� m DWCS. 0 BATT INSUI 2x RAFTERS PER Si RUAT: GYP. ED MASTER BEDROOM i JAL I ECUAL `I /]x GYP. SO, MULTI - PURPOSE ROOM If EXIST. SLAB ON GRADE FIN ,I �UILDINCx SECTION SCALE: I /4 " :I' -O" ER-P FACIA /z' GYP. BD. = WATERPROOFING SYSTEM OVER PLYWOOD DECK BEDROOM STORAGE WOOD FRAME P, EXIST. WOOD TRUSSES WINDOWS W/INSUL, SLIDING GLASS DOOR GLASS TO MATCH ASSEMBLY WITH INSUL. EXIST. _ - - CLASS 3/4" PLYWOOD TREAD 3/4" PLYWOOD RISER' SEE ti,4 "GYP. BD. (E) BEDROOM =0 FLOOR JOISTS (E) BEDROOM (E) BATH SEE STRJCT. DUGS. LAUNDRY (E) BEDROOM - 3 - z SrRINGERs TYPE 518• TYPE 'X' GYP. BID. R5ABL SPACE UNDER SiAll jr I -zx COWT. PRESSURE TREATED WOOD PLATE SHOT PINS AT 24. O.C. 4 STAIR AT 5LA5 SCALE: I I/1•:I' -O WGGO BASEBC 3/4" PLYW'OOO 3/4" PLYWOOD 2 SCALE: 11/4 ° --I' -O" .4 STUD FRAME FOR ACCESS PA A 5U�LDINC3 SECTION J SCALE! I /4" =1' -O" J FLOOR FRAMING PER FRAMING PLAN DBL. FLOOR JOISTS OR FLUSH BM. - SEE FRAMING PLAN 3 - 2.14 STRINGERS SB "TYPE 'X' GYP. BD. ATUSABLE "AIR UN STAIRS FRAME AT ACCESS METAL ANGLE AT OPENING PERIMETER GYP5UM BOARD W/ WEATHER5TRIFPING CEILING OATTIC ACCESS DETAIL SHAKES TO MATCH EXIST. NC OVER 30' BLDG. 2 DYER PLYWOOD DECK - -EE STRUCT b30 BATT INSUL. /1•GYP. BD. MASTER MASTER BATH BEDROOM WIND BAFFLE GTP, BD, WOOD FLOOR JOISTS SEE 5TRUCT,DWGS.- MULTI - PURPOSE ROOM m111. FELT RING OVER 5T UDT. METAL DRIP FLA514ING- CONi.CUTTER SYSTEM - s/4 x 0 CEDAR FACIA - 2 x BLOCKING W/ 3 - 2 "9 In- GWC R -30 BATT INSULATION 2 % S, STUDS A I6x CO W/ R -19 BATT INSULATIc In— 12 5 �TYEICAL EAVE DETAIL �J,-ALE 3q•, .. REVISIONS n &3 cn u °c� BEN a R I u� __j mgrs a R =<`s W U W WQ Z O J = TOP OFF PLATE ~ Q W W ¢m 0 O O J Na fD Q aW 1111 NZ 1.L /a�yy LL co `L 0 LU W N I U) Z J _ F- � W m 0 e I