Loading...
HomeMy WebLinkAbout01 - Eitel Residence Modification - PA2015-073 o4�Ewr°Q COMMUNITY DEVELOPMENT DEPARTMENT y PLANNING DIVISION u 100 Civic Center Drive, P.O. Box 1768, Newport Beach, CA 92658-8915 (949) 644-3200 Fax: (949) 644-3229 �q�fFOR�,P www.newportbeachca.gov CITY OF NEWPORT BEACH ZONING ADMINISTRATOR STAFF REPORT July 30, 2015 Agenda Item No. 1: SUBJECT: Eitel Residence Modification - (PA2015-073) 1723 Terrapin Way • Modification Permit No. MD2015-004 APPLICANT: TKR Construction — Ken Todd OWNER: Joe Eitel PLANNER: Jason Van Patten, Assistant Planner (949) 644-3234, jvanpatten@newportbeachca.gov ZONING DISTRICT/GENERAL PLAN • Zone: R-1-6000 (Single-Unit Residential) • General Plan: RS-D (Single-Unit Residential Detached) PROJECT SUMMARY A modification permit to allow a 974-square-foot addition to an existing 3,064-square- foot single-unit dwelling that is nonconforming due to the interior dimensions of the garage. The existing two-car garage provides an interior width of 19 feet 1 inch and a depth of 21 feet 5 inches, where a minimum 20-foot by 20-foot interior dimension is required. RECOMMENDATION 1) Conduct a public hearing; and 2) Adopt Draft Zoning Administrator Resolution No. — approving Modification Permit No. MD2015-004 (Attachment No. ZA 1). DISCUSSION • The subject property is located within the Harbor Highlands Community. The community is characterized by a mix of one-and two-story single-unit dwellings. 1 V� QP �P Eitel Residence Modification Zoning Administrator, July 30, 2015 Page 2 • The property is currently developed with a 3,064-square-foot single-unit dwelling with attached garage that was built in 1959. The property remained mostly unchanged until a small entry and powder room were added in 2011. At the time of original construction, the Zoning Code required a minimum of one garage space (covered and not less than 9 feet by 20 feet inside) for each single-unit dwelling. The garage has not been altered since the time of original construction. • The existing two-car garage is nonconforming due to the interior dimensions. The garage provides an interior width of 19 feet 1 inch and a depth of 21 feet 5 inches, where a minimum 20-foot by 20-foot interior dimension is required on lots wider than 40 feet. • Pursuant to Zoning Code Section 20.38.060 (Nonconforming Parking), additions to residential developments with nonconforming parking are limited to a maximum of 10 percent of the existing floor area of the structure. However, a larger addition may be allowed subject to the approval of a modification permit. In this case, the proposed addition represents approximately 32 percent (974 / 3,064) of the existing floor area of the structure. • The proposed addition consists of an expanded bedroom, bathroom, and storage area at the rear of the first floor, and a new second floor office, bedroom, and balcony. • Given the scope of work, increasing the width of the garage to 20 feet would result in a practical difficulty by requiring significant alterations to the garage and adjoining kitchen. Expanding the garage to the east is not feasible given the required setback. Expanding the garage to the west would require reconstruction and reconfiguration of the kitchen and would impact the existing electrical, plumbing, and gas lines that run through the wall. • The existing garage provides two useable garage spaces, thereby fulfilling the intent of the Zoning Code by providing adequate parking on site. Approval of the Modification Permit allows the applicant to continue use of the existing two-car garage, which has not proven detrimental to the occupants or neighbors of the dwelling. In addition, the driveway in front of the garage allows for the parking of a third vehicle on site. • The proposed addition will occur at the rear half of the property, will maintain a minimum distance of six feet from the nearest neighbor, and will provide adequate protection for light, air, and privacy. The addition will not preclude access to the dwelling and will be consistent in scale with other dwellings in the neighborhood that have two floors. TmpIt:04-17-14 Eitel Residence Modification Zoning Administrator, July 30, 2015 Page 3 ENVIRONMENTAL REVIEW The project is categorically exempt under Section 15301, of the State CEQA (California Environmental Quality Act) Guidelines - Class 1 (Existing Facilities). This exemption includes additions to existing structures provided that the addition will not result in an increase of more than 50 percent of the floor area of the structures before the addition, or 2,500 square feet, whichever is less. The project involves an addition of 974 square feet, or approximately 32 percent of the floor area of the existing single-unit dwelling. PUBLIC NOTICE Notice of this review was published in the Daily Pilot, mailed to all owners of property within 300 feet of the boundaries of the site (excluding intervening rights-of-way and waterways), including the applicant, and was posted on the subject property at least 10 days before the scheduled hearing, consistent with the provisions of the Municipal Code. Additionally, the item appeared on the agenda for this meeting, which was posted at City Hall and on the City website. APPEAL PERIOD: An appeal may be filed with the Director of Community Development within 14 days following the date of action. For additional information on filing an appeal, contact the Planning Division at (949) 644-3200. Prepared by: 3L��p a on Van Patten, Assistant Planner JM/jvp Attachments: ZA 1 Draft Resolution ZA 2 Vicinity Map ZA 3 Applicant's Project Description ZA 4 Site Photographs ZA 5 Project Plans TmpIt:04-17-14 J Attachment No. ZA 1 Draft Resolution 5 V� QP �P RESOLUTION NO. ZA2015-0## A RESOLUTION OF THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH APPROVING MODIFICATION PERMIT NO. MD2015-004 TO ALLOW A 974-SQUARE-FOOT ADDITION TO AN EXISTING SINGLE-UNIT DWELLING WITH NONCONFORMING PARKING LOCATED AT 1723 TERRAPIN WAY (PA2015-073) THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH HEREBY FINDS AS FOLLOWS: SECTION 1. STATEMENT OF FACTS. 1. An application was filed by TKR Construction, with respect to property located at 1723 Terrapin Way, and legally described as Lot 26 in Tract 3097 requesting approval of a modification permit. 2. The applicant proposes a modification permit to allow a 974-square-foot addition to an existing 3,064-square-foot single-unit dwelling that is nonconforming due to the interior dimensions of the garage. The existing two-car garage provides an interior width of 19 feet 1 inch and a depth of 21 feet 5 inches, where a minimum 20-foot by 20-foot interior dimension is required. 3. The subject property is located within the Single-Unit Residential Zoning District (R-1-6000) and the General Plan Land Use Element category is Single-Unit Residential Detached (RS-D). 4. The subject property is not located within the coastal zone. 5. A public hearing was held on July 30, 2015, in the Corona del Mar Conference Room (Bay E-1st Floor) at 100 Civic Center Drive, Newport Beach. A notice of time, place and purpose of the meeting was given in accordance with the Newport Beach Municipal Code. Evidence, both written and oral, was presented to, and considered by, the Zoning Administrator at this meeting. SECTION 2. CALIFORNIA ENVIRONMENTAL QUALITY ACT DETERMINATION. 1. This project has been determined to be categorically exempt pursuant to the requirements of the California Environmental Quality Act Guidelines under Class 1 (Existing Facilities). 2. The Class 1 exemption includes additions to existing structures provided that the addition will not result in an increase of more than 50 percent of the floor area of the structure before the addition, or 2,500 square feet, whichever is less. The project involves an addition of 974 square feet, or approximately 32 percent of the floor area of the existing single-unit dwelling. Zoning Administrator Resolution No. ZA2015-0## Page 2 of 6 SECTION 3. REQUIRED FINDINGS. In accordance with Section 20.52.050.E (Modification Permits — Required Findings) of the Newport Beach Municipal Code, the following findings and facts in support of such findings are set forth: Finding: A. The requested modification will be compatible with existing development in the neighborhood. Facts in Support of Finding: 1. The neighborhood is generally comprised of a development pattern of one-and two- story single-unit dwellings. The Modification Permit will allow a first and second floor addition and will result in a single-unit dwelling that is similar in bulk and scale to others in the Harbor Highlands Community. 2. The applicant is proposing a 974-square-foot addition to the existing dwelling. The proposed addition will comply with all applicable development standards, including lot coverage, height, and setbacks, and will not intensify or alter the existing nonconformities. 3. The existing development on the property is a single-unit dwelling. As such, there is no change to the density or intensity as a result of the proposed remodel and addition. Finding: B. The granting of the modification is necessary due to the unique physical characteristic(s) of the property and/or structure, and/or characteristics of the use. Facts in Support of Finding: 1. The interior dimensions of the existing two-car garage were in compliance with the Zoning Code at the time of original construction in 1959. However, as a result of amendments to the Zoning Code, the two-car garage is now substandard in size, and is therefore legal nonconforming. 2. The dwelling was designed with an attached garage that provides the minimum side setback required. The existing interior of the garage measures 19 feet 1 inch wide and 20 feet 5 inches deep. Expanding the width of the garage is not feasible without physically altering the interior of the floor plan or encroaching into the required setback. 3. The granting of the Modification Permit is necessary to allow a reasonable addition to an existing dwelling that was constructed in compliance with garage standards in effect at the time of original construction, and that are adequate in width for the parking 03-03-2015 g Zoning Administrator Resolution No. ZA2015-0## Page 3 of 6 of two (2) vehicles. In addition, the driveway in front of the garage allows for the parking of a third vehicle on site Finding: C. The granting of the modification is necessary due to practical difficulties associated with the property and that the strict application of the Zoning Code results in physical hardships that are inconsistent with the purpose and intent of the Zoning Code. Facts in Support of Finding: 1. Given the scope of work, increasing the width of the garage to 20 feet would result in a practical difficulty by requiring significant alterations to the garage and adjoining kitchen. Expanding the garage to the east is not feasible given the required setback. Expanding the garage to the west would require reconstruction and reconfiguration of the kitchen and would impact the existing electrical, plumbing, and gas lines that run through the wall. 2. The existing garage provides two (2) useable garage spaces, therefore fulfilling the intent of the Zoning Code by providing adequate parking on site. Approval of the Modification Permit allows the applicant to continue the use of the existing two-car garage, which has not proven detrimental to the occupants or neighbors of the dwelling. Finding: D. There are no alternatives to the modification permit that could provide similar benefits to the applicant with less potential detriment to surrounding owners and occupants, the neighborhood, or to the general public. Facts in Support of Finding: 1. The alternative would require that the applicant bring the existing two-car garage into conformance by expanding the existing garage. Expanding the garage towards the interior of the property would require significant alterations to the adjoining kitchen and living area. Expanding the width of the garage into the 6-foot side setback required by the Zoning Code is not feasible without a variance. 2. The other alternative is to reduce the size of the addition to not more than 10 percent of the existing floor area of the structure and to comply with the requirements of the Zoning Code. Given the proposal is to add a second floor, a redesign to reduce the size of the addition will significantly impact the intent of the project and not meet the objectives of the applicant. 03-03-2015 9 Zoning Administrator Resolution No. ZA2015-0## Page 4 of 6 Finding: E. The granting of the modification would not be detrimental to public health, safety, or welfare, to the occupants of the property, nearby properties, the neighborhood, or the City, or result in a change in density or intensity that would be inconsistent with the provisions of this Zoning Code. Facts in Support of Finding: 1. The proposed addition will occur on the rear half of the property, will maintain a minimum distance of 6 feet from neighboring properties, and will provide adequate protection for light, air, and privacy. The addition will not preclude access to the dwelling and will be consistent in scale with other dwellings in the neighborhood which have two (2) floors. 2. The existing nonconforming garage has not proven to be detrimental to the occupants of the property, nearby properties, neighborhood, or City and is adequate in width to park two (2) vehicles. 3. The proposed addition will result in site coverage that is less than the maximum allowed by the Zoning Code. 4. The approval of this Modification Permit is conditioned such that the applicant is required to obtain all necessary permits in accordance with the Building Code and other applicable Codes. SECTION 4. DECISION. kolow, NOW, THEREFORE, BE IT RESOLVED: 1. The Zoning Administrator of the City of Newport Beach hereby approves Modification Permit No. MD2015-004, subject to the conditions set forth in "Exhibit A," which is attached hereto and incorporated by reference. 2. This action shall become final and effective fourteen (14) days following the date this Resolution was adopted unless within such time an appeal is filed with the Community Development Director in accordance with the provisions of Title 20 Planning and Zoning, of the Newport Beach Municipal Code. PASSED, APPROVED, AND ADOPTED THIS 30TH DAY OF JULY, 2015. BY: Brenda Wisneski, AICP, Zoning Administrator 03-03-2015 2� Zoning Administrator Resolution No. ZA2015-0## Page 5 of 6 EXHIBIT "A" CONDITIONS OF APPROVAL 1. The development shall be in substantial conformance with the approved site plan, floor plans and building elevations stamped and dated with the date of this approval (except as modified by applicable conditions of approval). 2. The project is subject to all applicable City ordinances, policies, and standards, unless specifically waived or modified by the conditions of approval. 3. Each parking space within the garage shall be permanently available and maintained for parking purposes. The interior dimensions (19 feet 1 inch wide by 20 feet 5 inches deep) shall be kept clear of obstructions including cabinets, shelving, or similar that may impact the ability to adequately park two (2) vehicles. 4. The applicant shall install a new sewer clean out on the existing sewer lateral pursuant to City Standard STD-406-L. 5. The applicant shall remove all loose gravel from the parkway area. An encroachment permit and encroachment agreement shall be required for the decorative carriage walk within the Terrapin Way right-of-way. Private improvements shall be consistent with City Council Policy L-6. 6. This Modification Permit may be modified or revoked by the Zoning Administrator if determined that the proposed uses or conditions under which it is being operated or maintained is detrimental to the public health, welfare or is materially injurious to property or improvements in the vicinity or if the property is operated or maintained so as to constitute a public nuisance. 7. A copy of the Resolution, including conditions of approval (Exhibit "A"), shall be incorporated into the Building Division and field sets of plans prior to issuance of the building permits. 8. The applicant is required to obtain all applicable permits from the City's Building Division and Fire Department. The construction plans must comply with the most recent, City- adopted version of the California Building Code. 9. Should the property be sold or otherwise come under different ownership, any future owners or assignees shall be notified of the conditions of this approval by either the current business owner, property owner or the leasing agent. 10. Construction activities shall comply with Section 10.28.040 of the Newport Beach Municipal Code, which restricts noise-generating construction activities to between the hours of 7:00 a.m. and 6:30 p.m., Monday through Friday and 8:00 a.m. and 6:00 p.m. on Saturday. Noise-generating construction activities are not allowed on Sundays or Holidays. 03-03-2015 22 Zoning Administrator Resolution No. ZA2015-0## Page 6 of 6 11. This approval shall expire and become void unless exercised within twenty-four (24) months from the actual date of review authority approval, except where an extension of time is approved in compliance with the provisions of Title 20 Planning and Zoning of the Newport Beach Municipal Code. 12. To the fullest extent permitted by law, applicant shall indemnify, defend and hold harmless City, its City Council, its boards and commissions, officials, officers, employees, and agents from and against any and all claims, demands, obligations, damages, actions, causes of action, suits, losses, judgments, fines, penalties, liabilities, costs and expenses (including without limitation, attorney's fees, disbursements and court costs) of every kind and nature whatsoever which may arise from or in any manner relate (directly or indirectly) to City's approval of the Eitel Residence Modification including, but not limited to, MD2015-004 (PA2015-073). This indemnification shall include, but not be limited to, damages awarded against the City, if any, costs of suit, attorneys' fees, and other expenses incurred in connection with such claim, action, causes of action, suit or proceeding whether incurred by applicant, City, and/or the parties initiating or bringing such proceeding. The applicant shall indemnify the City for all of City's costs, attorneys' fees, and damages which City incurs in enforcing the indemnification provisions set forth in this condition. The applicant shall pay to the City upon demand any amount owed to the City pursuant to the indemnification requirements prescribed in this condition. 03-03-2015 Attachment No. ZA 2 Vicinity Map 13 V� QP �P 2� �2 ^1� III 11 s Subject Property y ?0 � 4 ^^tia s A 1 � Newport Beach Disclaimer: Every reasonable effort has been made to assure the accuracy of the data provided,however,The City of GIS Newport Beach and its employees and agents disclaim any and all responsibility from or relating to �� 'rogr any results obtained in its use. ° m 0 40 80 _ Imagery: 2009-2013 photos provided by Eagle Feet Imaging www.eagieaerial.com 4/21/2015 15 V� QP �P 2� Attachment No. ZA 3 Applicant's Project Description 17 V� QP �P sg June 30, 2015 �gGEIVEp 6} City of Newport Beach COMMUNITY Community Development JUL 0 ? 2015 100 Civic Center Drive Newport Beach, CA 92660 0 DEVELOPMENT Z RE: Letter of Justification for a Modification Permit: O�NEWPOo� �� The Eitel Residence Addition Owner: Joseph Eitel 1723 Terrapin Way Newport Beach, CA 92660 APN: 117-472-27 The project proposes to add to an existing SPR dwelling. The project will expand the existing home in two separate locations. One area will attach to an existing side of the house where no setback or non- conforming issues present themselves. The other addition area involves a garage that is existing non-conforming. The existing garage does not currently conform to the required width per the City of Newport Beach requirements. The existing garage is 19'-1" wide, and falls 11" short of the required 20'-0"width (less than 5% off of the code required width). It is not possible to extend the existing garage into the side yard because the garage is already at the required 6'-0" side yard setback, and adding the 1 I"Would cause us to encroach into the setback by that amount. It is impossible to widen the garage towards the house kitchen wall because of the existing utilities and finishes on that wall. The Kitchen has modern cabinets, countertops,tile backsplash, appliances, and other finishes—these would all be impacted by any wall relocation (see photos and plans). The current house water heater is mounted to that wall, and there is extensive electrical in the wall also to accommodate appliances on the other side of the wall that include the range, the refrigerator, and the washer and dryer. Gas and water piping run in that wall to feed appliances and the water heater. Additionally the run of cabinet against that garage wall cannot be moved, as only 3'-4" is left between those cabinets and the existing island at the tightest point. Moving that wall and the cabinets would create an impossible width at the island walk way. Mr. Eitel wishes to build a second story addition over the existing non-confirming garage that will serve as a bedroom or office. Both levels of the property will maintain the existing 6'-0" side yard setback. The front setback will not be effected, as the building will not be extended into the front yard. There will be an addition behind the garage on both levels, but this addition will be well within the allowable rear yard setback. Project Calculation (based on a comprehensive and verified field measure) • Existing First Floor Residence: 2,629.71 sf • Existing Garage: 433.87 sf • Proposed First Floor Addition: 437.96 sf • Proposed Second Floor Addition: 536.08 sf • Total Proposed HOUSE (living): 3,603.75 sf • Total Proposed HOUSE and GARAGE: 4,037.62 sf • Total Proposed DECK: 80.79 sf • Total Proposed Built Space (House+Deck+ Garage): 4,118.41 sf PA2015.073 for MD2015-004 1723 Terrapin Way 29 TKR Construction How the proposed use is justified: Compatibility with the Existing Neighborhood The materials used and the architectural style of the remodel will match the existing detailing of the home,and be completely consistent with the existing home and the existing neighborhood. The granting of this Modification Permit would not be detrimental to nearby properties,the neighborhood,the city,or to public health and safety. The project will be appropriate for the Newport Beach residential area that it is located in,and have proper scale and compatibility. Unique physical Characteristics of the Property The property is unique in that the existing garage does not have sufficient width. It would appear as if there has been remodeling to the home in the past,both by Mr. Eitel and by previous owners. The house is in wonderful condition,and all finishes in the home are either new or extremely well maintained. The garage area of the house has nowhere to expand into at this time without tearing apart a very nice looking and functional home. Practical Difficulties Associated with the Property The practical difficulties with the property are detailed above in the body of this document. There are No Alternatives There are currently no other options for Mr. Eitel to gain additional space for his growing family and their needs. Detrimental to Pubic Health The proposed addition and"attachment'to the existing garage will in no way effect the public health and safety or the Public Health of other residents, visitors or others concerned. The addition will match the existing architecture and will enhance the appearance of the current residence. Sincerely, Agent for the O er—Architect/Contractor Ken Todd 20 Attachment No. ZA 4 Site Photographs 21 V� QP �P �Y e - - , ( . _. rp o,_ � V� QP �P Attachment No. ZA 5 Project Plans 25 V� QP �P PA2015-073 Attachment No . ZA 5 - Project Plans NPDES NOTES SHEET INDEX NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) NOTES A-1 TITLE SHEET, SITE PLAN AND NOTES 1. IN THE CASE OF EMERGENCY,CALL KEN TODD AT WORK PHONE# 562-493-0429 OR HOME PHONE#562-708-8914. A-1.1 OVERLAY PLAN AND NOTES 2. SEDIMENT FROM AREAS DISTURBED BY CONSTRUCTION SHALL BE RETAINED ON SITE USING 1 00.00' P.L. STRUCTURAL CONTROLS TO THE MAXIMUM EXTENT PRACTICABLE. --- ------ -------------------- A-1.2 OVERLAY PLAN AND NOTES 3. STOCKPILES OF SOIL SHALL BE PROPERLY CONTAINED TO MINIMIZE SEDIMENT TRANSPORT A-2 1ST FLOOR DEMO PLAN AND NOTES FROM THE SITE TO STREETS, DRAINAGE FACILITIES OR ADJACENT PROPERTIES VIA RUNOFF, I / VEHICLE TACKING,OR WIND. EXISTING / A-3 1ST FLOOR PLAN AND NOTES 4. APPROPRIATE BMP'S FOR CONSTRUCTION-RELATED MATERIALS,WASTES,SPILLS SHALL BE I POOL IMPLEMENTED TO MINIMIZE TRANSPORT FROM THE SITE TO STREETS, DRAINAGE FACILITIES, EQUIPMENT A-4 2ND FLOOR AND ROOF PLAN OR ADJOINING PROPERTIES BY WIND OR RUNOFF. I / 5. RUNOFF FROM EQUIPMENT AND VEHICLE WASHING SHALL BE CONTAINED AT CONSTRUCTION I / A-5 EXTERIOR ELEVATIONS \ SITES UNLESS TREATED TO REDUCE OR REMOVE SEDIMENT AND OTHER POLLUTANTS. I - EXISTING 6. ALL CONSTRUCTION CONTRACTOR AND SUBCONTRACTOR PERSONNEL ARE TO BE MADE to LAWN AWARE OR THE REQUIRED BEST MANAGEMENT PRACTICES AND GOOD HOUSEKEEPING ILh ' MEASURES FOR THE PROJECT SITE AND ANY ASSOCIATED CONSTRUCTION STAGING AREAS. 7. AT THE END OF EACH DAY OF CONSTRUCTION ACTIVITY ALL CONSTRUCTION DEBRIS AND I PROPOSED WASTE MATERIALS SHALL BE COLLECTED AND PROPERLY DISPOSED IN TRASH OR RECYCLE 1st FLR.PRO PE D BINS. O OADD ITI ON m 1 z 8. CONSTRUCTION SITES SHALL BE MAINTAINED IN SUCH A CONDITION THAT AN ANTICIPATED N STORM DOES NOT CARRY WASTES OR POLLUTANTS OFF THE SITE.DISCHARGES OF MATERIAL 154.58 .F. _ PROPOSED UIt OTHER THAN STORMWATER ONLY WHEN NECESSARY FOR PERFORMANCE AND COMPLETION OF CONSTRUCTION PRACTICES AND WHERE THEY DO NOT:CAUSE OR CONTRIBUTE TO A I BALCONY ~ o VIOLATION OF ANY WATER QUALITY CAUSE OR THREATEN TOCONTAMINAT ON, OR NU SANCE; OR CON AAIN A HAZARDOUS SUBSTANCES INAUSE A QUANTITY ION, I 80.79 S.F. r O EXISTINGLL REPORTABLE UNDER FEDERAL REGULATIONS 40 CFR PARTS 117 AND 302. I HARDSCAPE N `Z Q 04 9. POTENTIAL POLLUTANTS INCLUDE BUT ARE NOT LIMITED TO:SOLID OR LIQUID CHEMICAL 1 PROPOSED / li < m (D SPILLS; WASTES FROM PAINTS, STAINS, SEALANTS, GLUES, LIMES,PESTICIDES, HERBICIDES, 1 0 WOOD PRESERVATIVES AND SOLVENTS;ASBESTOS FIBERS, PAINT FLAKES OR STUCCO 1st FLR. ADDITION ' U) 0- o a FRAGMENTS; FUELS, OILS, LUBRICANTS, AND HYDRAULIC, RADIATOR OR BATTERY FLUIDS; I 283.38 S.F. Z O � z FERTILIZERS,VEHICLE/EQUIPMENT WASH WATER AND CONCRETE WASH WATER;CONCRETE, DETERGENT OR FLOATABLE WASTES;WASTES FROM ANY ENGINE/EQUIPMENT STEAM 1 - _ __ 0 J W CLEANING OR CHEMICAL DEGREASING AND SUPER CHLORINATED POTABLE WATER LINE j -- j - / U W LO O N FLUSHING. J W It DURING CONSTRUCTION, PERMITTEE SHALL DISPOSE OF SUCH MATERIALS IN A SPECIFIED w O U Z ID AND CONTROLLED TEMPORARY AREA ON-SITE, PHYSICALLY SEPARATED FROM POTENTIAL m O STORMWATER RUNOFF,WITH ULTIMATE DISPOSAL IN ACCORDANCE WITH LOCAL,STATE AND 1 _-- i / O FEDERAL REQUIREMENTS. 10. DEWATERING OF CONTAMINATED GROUNDWATER, OR DISCHARGING CONTAMINATED SOILS I VJ L() VIA SURFACE EROSION IS PROHIBITED. W DEWATERING OF NON-CONTAMINATED GROUNDWATER REQUIRES A NATIONAL POLLUTANT 1 VICINITY MAP o DISCHARGE ELIMINATION SYSTEM PERMIT FROM THE RESPECTIVE STATE REGIONAL WATER 1 PROPOSED '-' QUALITY CONTROL BOARD. I 1 11. GRADED AREAS ON THE PERMITTED AREA PERIMETER MUST DRAIN AWAY FROM THE FACE OF 2nd FLR ADDITION /�- SLOPES AT THE CONCLUSION OF EACH WORKING DAY.DRAINAGE IS TO BE DIRECTED TOWARD I 1 536.08 S.F. DESILTING FACILITIES. JI 12. THE PERMITTEE AND CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE NECESSARY d i � 0) PRECAUTIONS TO PREVENT PUBLIC TRESPASS ONTO AREAS WHERE IMPOUNDED WATER I EXI5T. I CREATES A HAZARDOUS CONDITION. �I 7'- " j �a �s 13. THE PERMITTEE AND CONTRACTOR SHALL INSPECT THE EROSION CONTROL WORK AND I ; - INSURE THAT THE WORK IS IN ACCORDANCE WITH THE APPROVED PLANS. 00 00 14. THE PERMITTEE SHALL NOTIFY ALL GENERAL CONTRACTORS, SUBCONTRACTORS, MATERIAL 7-I SUPPLIERS, LESSEES,AND PROPERTY OWNERS:THAT DUMPING OF CHEMICALS INTO THE EXISTING Q I / STORM DRAIN SYSTEM OR THE WATERSHED IS PROHIBITED. RESIDENCE CI DCACE 15. EQUIPMENT AND WORKERS FOR EMERGENCY WORK SHALL BE MADE AVAILABLE AT ALL TIMES I 2,66279.7111 VS.F.C DURING THE RAINY SEASON. NECESSARY MATERIALS SHALL BE AVAILABLE ON SITE AND I STOCKPILED AT CONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCTION OF TEMPORARY DEVICES WHEN RAIN IS IMMINENT. 16. ALL REMOVABLE EROSION PROTECTIVE DEVICES SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE 5-DAY RAIN PROBABILITY FORECAST EXCEEDS 40%. I - I � 17. SEDIMENTS FROM AREAS DISTURBED BY CONSTRUCTION SHALL BE RETAINED ON SITE USING I I AN EFFECTIVE COMBINATION OF EROSION AND SEDIMENT CONTROLS TO THE MAXIMUM _ EXTENT PRACTICABLE,AND STOCKPILES OF SOIL SHALL BE PROPERLY CONTAINED TO MINIMIZE SEDIMENT TRANSPORT FROM THE SITE TO STREETS, DRAINAGE FACILITIES OF ADJACENT PROPERTIES VIA RUNOFF, VEHICLE TRACKING, OR WIND. 1 -- 18. APPROPRIATE BMPS FOR CONSTRUCTION-RELATED MATERIALS,WASTES,SPILLS OR - RESIDUES SHALL BE IMPLEMENTED AND RETAINED ON SITE TO MINIMIZE TRANSPORT FROM ( /I � THE SITE TO STREETS, DRAINAGE FACILITIES, OR ADJOINING PROPERTY BY WIND OR RUNOFF. 1 ' 1723 TERRAPIN WAY SECURITY ORDINANCE I it ' /Q0 1. SLIDING GLASS DOORS AND WINDOWS LOCATED LESS THAN 16 FEET ABOVE ANY I 1 ' OWNER LLJ V SURFACE AVAILABLE FOR USE BY THE PUBLIC SHALL BE CAPABLE OF BEING LOCKED U SECURELY. MOVEABLE PANELS SHALL NOT BE EASILY REMOVED FROM THE FRAME, EXISTING 2. ALL MAIN OR FRONT ENTRY TO DWELLINGS SHALL BE ARRANGED SO THAT THE DRIVEWAY ' JOSEPH EITEL OCCUPANT HAS A VIEW OF THE AREA IMMEDIATELY OUTSIDE WITHOUT OPENING OTHER OPENING. >_ V DOOR. SUCH VIEW MAY BE PROVIDED BY A DOOR VIEW,A VIEW PORT,WINDOW, OR `-------- ------------------------------------I 1723 TERRAPIN WAY 3. EXTERIOR WOODEN DOORS SHALL BE OF SOLID CORE CONSTRUCTION OR SHALL BE I I NEWPORT BEACH, CALIFORNIA 92660 LLI COVERED THE INSIDE FACE WITH 16 GAUGE SHEET METAL ATTACHED WITH I -_ PHONE: 562 . 493 . 0429 Q _ SCREWS ATT 6 6 INCH ON CENTERS AROUND THE PERIMETER. I Q 4. ALL SWINGING DOORS SHALL BE EQUIPPED WITH A DEAD BOLT WITH A MINIMUMf , THROW OF 1 INCH AND AN EMBEDMENT OF NOT LESS THAN 5/8 INCH. Ory V 5. THE INACTIVE LEAF OF A PAIR OF DOORS AND THE UPPER LEAF OF DUTCH DOORSEXISTING / SHALL BE EQUIPPED WITH A DEAD BOLT. i Z LAWN '/nOOQ� p LEGAL DESCRIPTION Cn zw 6. NON-REMOVABLE PINS SHALL BE USED IN PIN TYPE HINGES WHICH ARE ACCESSIBLE I G FROM THE OUTSIDE WHEN THE DOOR IS CLOSED. x /� I 1 I < M 7. UNFRAMED GLASS DOORS SHALL BE FULLY TEMPERED GLASS NOT LESS THEN '/ INCH I W LOT 26 W LJJ THICK. 8. NARROW-FRAMED GLASS DOORS SHALL BE FULLY TEMPERED GLASS NOT LESS THAN j �� TRACT 3097 MARINERS COMM. ASSOC. LL '/< INCH THICK. / 9. ANY GLASS WHICH IS LOCATED WITH IN 40 INCHES OF THE LOCKING DEVICE ON A / APN 117 - 472 - 27 DOOR SHALL BE FULLY TEMPERED, OR HAVE APPROVED METAL BARS, SCREENS OR ___ ______ ____ _______ __- 3�` O 10. SOLID WOODEN HATCHWAYS LESS THAN1-3/4INCHES THICK SHALL BE COVERED ON 37.34GRILLS. ' P.L_ L DESIGNER w THE INSIDE WITH 16 GAUGE SHEET METAL ATTACHED WITH SCREWS AT 6 INCH ON CENTER AROUND THE PERIMETER AND SHALL BE SECURED FROM THE INSIDE WITH A SLIDE BAR, SLIDE BOLTS, AND/OR PADLOCK WITH HARDENED STEEL SHACKLE.ALL co M OTHER OPENINGS LARGER THAN 96 SQUARE INCHES WITH A DIMENSION IN EXCESS NORTH SITE PLAN TKR CONSTRUCTION - KEN TODD ti OF 8 INCHES SHALL BE SECURED BY METAL BARS, SCREENS,AR GRILLS. (EXCEPTION: W NON-OPENING SKYLIGHTS). PO BOX 5O8 11. WIITHVFULLLPY-MENT NC OS DHGARAG S. GARAGES SPACEINCLUDES 3 OR MORE EFOR EACHLLING T ENANT SHAS SHALL BE LL PROVIDED SITE LEGEND Z SEPARATED BY PARTITIONS OF 3/8 INCH PLYWOOD OR EQUIVALENT WITH STUDS SET SCALE: N.T.S. LOS ALAM ITOS, CA 90720 NO MORE THAN 24 INCHES ON CENTER. OFFICE . 562 . 493 . 0429 C TERRAPIN WAY ® 1ST FLOOR ADDITION CELL . 562 . 708 . 8914 SITE NOTES 2ND FLOOR ADDITION ENGINEER 1. LANDSCAPE AND HARDSCAPE SHOWN ARE SUBJECT TO CHANGE. LO VERIFY WITH OWNER FOR ALL LANDSCAPE ARCHITECTURE FOR BOTH _ T_ FRONT AND REAR OF HOME. 2. PROPERTY MARKERS MUST BE VISIBLE AT THE TIME OF INSPECTION f` OR SURVEYSTREETNUMBWILLREQUIRED. CONDITIONS OF APPROVAL BUILDING AREA TABULATION CODE DATA - 3. HOUSE STREET NUMBER WILL BE VISIBLE AND LEGIBLE FROM STREET. ALL WORK SHALL CONFORM TO 2013 CRC, CBC, CPC, H 4. THE DISCHARGE OF POLLUTANTS TO ANY STORM DRAINAGE SYSTEM 1 . INSTALL NEW SEWER CLEAN OUT D- EXISTING SEWER EXISTING FIRST FLOOR: 2,629.71 S.F. CMC, CEC AND 2013 CA. ENERGY BUILDING DEPT. INFO. IS PROHIBITED. NO SOLID WASTE PETROLEUM BY PRODUCTS, SOIL LATERAL PER CITY STANDARDS STD-406-2. PROPOSED FIRST FLOOR ADDITION: 437.96 S.F. PARTICULATE, CONSTRUCTION WASTE MATERIALS, OR WASTE WATER ZONE: R-1 6,000 m GENERATED ON STIES OR BY CONSTRUCTION ACTIVITIES SHALL BE 2. REMOVE ALL LOOSE GRAVEL FROM THE PARKWAY AREA. AN PROPOSED SECOND FLOOR ADDITION: 536.08 S.F. CITY OF NEWPORT BEACH PROJECT EITEL RESIDENCE ��/� PLACED, CONVEYED OR DISCHARGED IN TO THE STREET GUTTER OR ENCROACHMENT PARMIT AND ENCROACHMENT AGREEMENT pROPOSED 2ND FLOOR DECK: 80.79 S.F. CONSTRUCTION: TYPE V-B DRAM er KT/JY `�+ STORM DRAIN SYSTEM. WILL BE REQUIRED FOR THE DECORATIVE CARRIAGE WALK OCCUPANCY: R 3 SFR - RESIDENCE/U-GARAGE BUILDING DEPT. CAD FILE NAME EITEL W/IN THE TERRAPIN WAY RIGHT AWAY. EXISTING GARAGE: 433.87 S.F. LJJ 5. SEPARATE PERMIT(S) S,ARE REQUIRED FOR ACCESSORY BUILDING 100 CIVIC CENTER DRIVE PLOT DATE fl-50-15 � PATIO COVERS FENCES, SWIMMING POOL, RETAINING WALLS TOTAL LIVING: 3,603.75 S.F. EXISTING SPRINKLER SYSTEM: NO NEWPORT BEACHCA92660 Z DEMOLITION, ETC. NUMBER OF STORIES: 2 STORY , , T-T-Is AND COUNTY PROPERTY PERMIT FOR THE NEW DRIVEWAY TOTAL HOUSE: 4,037.62 S.F. ALLOWABLE BUILDING HEIGHT: 24'-0" FOR FLAT ROOFS 949 . 644 . 3288 O APPROACH. 29'-0" FOR PITCHED: 3/12 MIN. H 6. GEOTECHNICAL OR SOIL REPORT SHALL BE APPROVED BY THE THE EXISTING HOUSE SQUARE FOOTAGE HAS BEEN FIELD VERIFIED SCOPE O F WORK o U GRADING SECTION PRIOR TO BUILDING PLAN APPROVAL. PER OUR FIELD MEASURE AND SITE VISITS. LOT COVERAGE INCLUDING OVERHANGS: 3,928.05 S.F. 7. BUILDING PERMIT WILL NOT ISSUE UNTIL GRADING PLAN IS 60% MAX LOT COVERAGE 0 LL APPROVED AND ISSUED. PROPOSED LOT COVERAGE = 41.89% ADDITION TO HOUSE 974.04 S.F. ADDITION TO. MASTER SUITE, REAR Q 8. THERE SHALL BE NO TRENCHES OR EXCAVATIONS 5 FEET OR MORE IN FRONT SETBACK: 20'-0" OF GARAGE FOR PLAY ROOM AND SECOND FLOOR ADDITION 0 DEPTH INTO WHICH A PERSON IS REQUIRED TO DESCEND; OR OBTAIN SITE AREA TABULATION SIDE SETBACK: 6-0" ABOVE GARAGE FOR BEDROOM/OFFICE. FRONT FACADE REMODEL. A NECESSARY PERMIT FROM STATE OF CALIFORNIA, DIVISION OF 2nd FLOOR BALCONY 80.79 S.F. INDUSTRIAL SAFETY PRIOR TO THE ISSUANCE OF A BUILDING OR REAR SETBACK: 6'-0" Al >_ GRADING PERMIT. SITE AREA 9,377 S.F. - U 2:7-'- PA2015-073 Attachment No . ZA 5 - Project Plans • • F —I I I I I I $'-II I/6„ I I I II Z O 04 Cn 1 0 It In Z goL`Lu � CV I G Q � 113/16° Z Ga O z 0 00 ItF�r _ - - - - - - - - - - - - - - - - _ O 1 ' ® O O0 rn Lu "' LL J Z w m0 U � O / (7 = 0) 11 0- CV W (c) I � / s 1 c 1 w 1 n A / � 1 / 1 F 4'-5 -7/161 m 1 n 1 1 O W co N U N Z Q 1 w QU i $ FLOOR AREA S.F. C) A 15LIed8 _ (� o i G G 84�04 Z Q m 1 � m D 166.38 'v j a 1 E 117.0 u J Q m ry E 433.87 i � C 16.x8 1 H 51�g2 J LuO J 4.13 w 1 K 58.61 W ~ 1. - - - - - - - - - - TOTAL: 5,501 .54 M 1 ~ W K $� m `� PROPOSED 1ST FLOOR OVERLAY PLAN w 1 SCALE: 114 = 1'-0" ism 111-311lip-mb.1 I ti I ti J Q H H WALL LEGEND m EXISTING TO REMAIN PROJECT EITEL RESIDENCE DRAM 5r KT/JY `�I+ EX. NALL TO BE REMOVED GAD FILE NAME EITEL PLOT DATE 6-50-15 LI. NEW 2X4 STUD ® 16" O.G. 'r-T-Is Z A p O' 1' 5' 10' A LL cl HATCHING INDICATESA- 1 ■ O AREAS BEING MODIFIED C U 2g PA2015-073 Attachment No . ZA 5 - Project Plans I I I I I I I I I F- I I I I I I I I • I I I I \ _ 004 rn UOP � cc,)) Z Q C, I • CN LLJ < o Lo L M za oz I • 0 � 00 0-1 I • N STAIRS NOT INCLUDED J o U- N I • m IN FOOTAGE CALCULATION. U � x � w o TAIRS COUNTED ON FIRST z W m U z m m FLOOR. 26.54 S.F. (� p Oz '- HEAD HEIGHT LESS THAN 6'-O" a a � m W I I ' m I I if n Q / I / P I • I ' I � I I I _ I I I w N I _ - - - _ _ - FLOOD AREA S.E.-7 Z Q I I / M 65.31 W Q U I I N 52.31 C) > _ I I O 14.87 I I F IcI5.25 V 0 133.37 v) z Q I TOTAL: 536.08UJ t ' Q m LLJ I I I I � ~ / J w0 Ir W �>> N w ti > Itl I I r I I PROPOSED 2ND FLOOR OVERLAY PLAN SCALE: 1/4 = V-0" I ti I ti J Q H H WALL LEGEND m EX15TINO TO REMAIN PROJECT EITEL RESIDENCE DRAM BY KT/JY ` I+ EX. HALL TO BE REMOVED GAD FILE NAME EITEL - - - - - - - - - - - � PLOT DATE 6-50-15 LL NEW 2X4 STUD ® 16" O.G. 'r-T-Is Z p I 5 ZL Q LL cl HATCHING INDICATESA- ■ O AREAS BEING MODIFIED G U �9 PA2015-073 Attachment No . ZA 5 - Project Plans u JL � _ REMOVE r WINDOW REMOVE LS EXIT TO EX. TYF. GARAGE REMOVE BBQ AREA Z Ly ' - - _ -- REMOVE ALL CABINETRY ~ O AND PLUMBING FIXTURE5. U GAP UTILITYS FOR / / D Z O LL. NEW WORK. L L W <, 0 Ln U) O ¢ I i REMOVE / ZJ Z WALL5 0 _ - - TYP. J 003 O U W LO LL N REMOVE > X J W It •., ; _�®��I I� _ r DOORS L �I w Q Q Z O - � - - - �JI � _U o It y _ s. r - REMOVE \�/� \u/ LO DOOR5 MASTERW ' BATHROOM/n� ✓/n\ �LL Q EXISTING KITCHEN WALL Z 0 z F 4 0 z c N EXIT TO EX. EXISTING EXISTING GARAGE APPLIANCE PANTRIES --- WALL CY) II IIII 11 - UJ `fl (INS/DZ D/t„lZFNS /aN) Z >- U LU Q -. C) — zQ � w LU Q m DEMO PLAN LLI M SCALE: 1/4 = 1'-0" (V LU LIJ V-- z EXISTING KITCHEN WALL IUD ti ti LEGEND AND NOTES Q WALL LEGEND m PROJECT EITEL RESIDENCE �D RWN DABY KT/JY ` ) EXI5TINO TO REMAIN CAD FILE NAME EITEL /UN. 0. PLOT DATE 6-50-15 EX. WALL TO BE REMOVED 1-1-15 Z p Q O' I' 5. 10, U D L- A2 U �o PA2015-073 Attachment No . ZA 5 - Project Plans 22'-3" • DOUBLEE SLIDER I I gZ ' r - - - - - - - - - - 9, — `o • z w WALKZA wo y CLOSET zz 4 Q D7 0 04 lum t— w \ CLOSET DOORS — CLOSET DOORS — Q 4 `\ FRES"DORS p UN w ¢ CN I�_ CO Ln U SAT Xd I o G n " a OJ Z N DR Z" STORAGE 00-1 - - - - - - - - - - - - - - - - - - n3� ROOM U J LLJ 00 O CLOSET ORGANIZER $ CUSTOM > X J W � SERVICELO m o} HALL 26' ABIN-//" BUILT-EN 'ZIP w m U p m 31—III 3Q SG.pR 7-5�� � 0 Q = It z C _1 LLI `n LIVING ROOM ; z�� "AUXr z �bTI� -3 wx66 �� 'Er z0 g r ;EXISTIN n gu DRAWERS - _ KITCHE 51 NK ---- SINK N LINE OF VO" HEAD HEIGHT ry EX15TINO i TANKLEss ; ® EXISTING m HATER -- 2-CAR GARAGE HEATER Z N EXISTING EXISTING z BEDROOM #2 w DINING ROOM - w EXISTING z c BAR AREA O7 N W Q N EXISTING BATHROOM #1 EXISTING J&J BATHR OM % uJ - F'�� NS/ON) z < jillp I�/I!I EXISTING EXISTING W Q m LIBRARY ENTRY m J w0 W ~ � EXISTING N W BEDROOM #3 co LLj V_ Z PROPOSED 1ST FFLOOR PLAN m SCALE: 1/4 = 1'-0" I4'-II 7/16" '-7 5116 ' 2I'-6 3/8" 7'-5 7/16" I ti I ti LEGEND AND NOTES Q GENERAL NOTES ADDITIONAL BLDG DEPARTMENT NOTES WALL LEGEND EXTERIOR WALL DIMENSIONS ARE TO EXTERIOR FACE OF STUD SHOWER - FOR GARAGE SEPERATION FROM THE DWELLING UNIT: SMOKE AND CARBON DETECTOR NOTES m UNLESS NOTED OTHERWISE. PROVIDE ANTI-SCALDING SHOWER AND TUB SHOWER VALVES PROVIDE SEPERATION WITH 5/8" TYPE 'X' GYPSUM BOARD - MIN 1. FIELD VERIFY THAT SMOKE DETECTORS EXISTING IN BEDROOMS EXISTING TO REMAIN PROJECT EITEL RESIDENCE INTERIOR WALL DIMENSIONS ARE TO FACE OF STUD UNLESS NOTED OTHERWISEWALL COVERING SHALL BE CEMENT PLASTER, TILE OR APPROVED EQUAL FOR GARAGE SEPERATION FROM THE ATTIC AND HALLS LEADING TO BEDROOMS PER CODE. IF NONE DRAM 5r KT/-r EXIST INSTALL SMOKE DETECTORS. CONTRACTOR TO SUBMIT ALL FINISH SAMPLES TO THE ARCHITECT OR OWNER ABOVE DRAIN INLET AT SHOWERS OR TUB WITH SHOWERS. PROVIDE SEPERATION WITH 1/2" TYPE 'X' GYPSUM BOARD - MIN EX. HALL TO BE REMOVED GAD FILE NAME EITEL LI J PRIOR TO INSTALLATION FOR APPROVAL MATERIALS OTHER THAN STRUCTURAL ELEMENTS TO BE MOISTURE RESISTANT. ENCLOSED USABLE SPACE UNDER INTERIOR STAIRS REQUIRES 1-HOUR 2. FIELD VERIFY THAT CARBON MONOXIDE DETECTORS EXISTING IN PLOT DATE 6-30-I5 (i.e. FLOORING, TRIM, MOULDING, WOOD SIDING, ... ETC.) WATER CLOSETS - 30" (MIN) CLR WIDTH & 24" (MIN) CLR IN FRONT FIRE RESISTIVE CONSTRUCTION ON THE ENCLOSED SIDE HALLS LEADING TO BEDROOMS PER CODE. IF NONE EXIST INSTALL T-T-15 INSTALL CABON MONOXIDE DETECTORS. NEW 2x4 5TUD ® 16' O.G. Z FIREBLOCKING, VERTICAL OR HORIZONTAL SHALL CONFORM TO CBC 708.2. SAFETY GLAZING OR TEMPERED GLAZING - PROVIDE 22x30 ATTIC ACCESS AT ALL ATTIC AREAS WITH A A O HEADROOM THAT EXCEEDS 30" AFTER INSTALLING INSULATION, THE INSTALLER SHALL POST IN A CONSPICUOUS REQUIRED AT SHOWER ENCLOSURES, WINDOWS AT STAIR LANDINGS, EXACT LOCATION TO BE DETERMINED BASED ON ROOF TRUSS LAYOUT O' I' S' 10' Q LOCATION IN THE BUILDING A CERTIFICATE SIGNED BY THE INSTALLER AND THE GLAZING AT DOORS AND SIDELIGHTS, AND OTHER HAZARDOUS LOCATIONS. REQUIRED FLOW RATES / ZL BUILDER STATING THAT THE INSTALLATION CONFORMS WITH THE REQUIREMENTS WATER CLOSETS: 1.6 gpm �- U OF TITLE 24, PART 6, AND THAT THE MATERIALS INSTALLED CONFORMS WITH A PERMANENT LABEL SHALL IDENTIFY EACH LIGHT OF SAFETY GALZING. SHOWER HEADS: 2.5 gpm �O%��O/��O/� IL THE REQUIREMENTS OF TITLE 20, CHAPTER 2. THE CERTIFICATE SHALL STATE LAUNDRY FAUCETS: 2.2 gpm Q LLTHE MANUFACTURER'S NAME AND MATERIAL IDENTIFICATION, THE INSTALLED EXTERIOR LATH: PPROVIDE TWO LAYERS OF GRADED PAPER EGRESS BLDG DEPARTMENT NOTES LAVATORY FAUCETS: 2.0 gpm Q R-VALUE AND THE WEIGHT PER SQUARE FOOT. OVER ALL WOOD BASE SHEATHING KITCHEN FAUCETS: 2.2 gpm PROVIDE WATER RESISTANT GYPSUM BACKING BOARD AS A BASE FOR TILE OR WINDOWS AND DOORS VERIFY EMERGENCY EGRESS FROM SLEEPING ROOMS PROVIDE ULTRA FLUSH WATER CLOSETS FOR MIN 24" CLR HT, 20" CLR WIDTH, 5.7 SF MIN AREA, ALL NEW CONSTRUCTION EXISTING SHOWER HATCHING INDICATES �� WALL PANELS FOR TUB OR SHOWER ENCLOSURES OR WATER CLOSET ALL NEW WINDOWS AND DOORS SHALL HAVE A LABEL INDICATION THE U-FACTOR AND 44" MAX TO SILL HEADS AND TOILETS MUST BE ADAPTED FOR AREAS BEING MODIFIED COMPARTMENT WALLS AND SHGU. ALSO SHALL COMPLY WITH ENERGY DOCUMENTATION REQUIREMENTS. LOW FLOW WATER CONSUMPTION ALL NEW WINDOW MATERIAL SHALL BE VINYL, AND DUAL GLAZED LOW-E PROVIDE MINIMUM 7'-6" CEILING HEIGHT AT MEANS OF EGRESS U 31 PA2015-073 Attachment No . ZA 5 - Project Plans NEW ROOF OVER ADDITION AREA. ROOFING TO MATCH EXISTING. I ROOF LEOEND I I NEW ROOF NEW ROOF OVER ROOF VENT: HALF ROUND DORMER VENT OVER ADDITION 19'_ ADDITION AREA. GJ METAL PRODUCTS INC. OR EQUAL y �Q AREA. ROOFING / ROOFING TO 800-500-8660 WWW.CJMETAL5.COM F- TO MATCH EXISTING. 14'_ „ MATCH EXISTING. MODEL # MM30 OR EQUAL N. 4:12 OPENING SHALL HAVE R �EI OROTHER APPROVED MATERIAL WITH \ I 1/6" MINIMUM AND 1/4" MAX OPENING ` `r - - - - � L - - - PITCH ALL AREAS:ROOF 4:12 FIELD VERIFY \\, - - - - _ _ _ _ N I _ _ ROOF OENERAL NOTES w �� - - _ g~ll DALE 5R 0 m z I. PROVIDE ROOF VENTING IN ALL NON-VAULTED N I�� I AREAS PER GPC VERIFY W/ MANUFACTURER FOR 0 JENS OFFICE / ADDITIONAL REQUIREMENT5 (n It 2. ROOFING AT SLOPED FORMS: j t o LL ry MANUF: GAF TIMBERLINE ROOFING E5R 1415 Z Q N 04P I 8'-4" GLA QUAAL COMPOSITE SHINGLE _<j � lll e� TYPE: 5 - TILE ROOF Q COLOR: TO BE DETEMINED (Z 0 _ ger T-- UNDERLAYMENT: 2 LAYERS BLDG FELT PER MANUF. Z O _j z RECOMMENDATIONSQ J 00-1 W ry a I p ��MEr �oK SLOPE: 4:12 (EXISTING) 0 0 Ljjm ry �u 7 ALF LO 3. EAVE CONDITON5 U > Lij z O _J z o RAKE: O" AND 6" OVERHANG (SEE PLAN)7 mUO � m a 3'-gyp„ EAVE: 12" AND 15" OVERHANG (SEE PLAN) C7 a d N a0 _ !Il CO ry v �r llm� Fn Lq 151, LLI ui I ` iri Q w° � I ATTIC. VENTING I PDssrsLecLDSEr 10 Ist FLOOR ROOF . I SPACE m ATTIC AREA (NON-VAULTED) PX. 4:12 APPROX 1,413 5F. jn 6 VENTS ® .66 S.F. EA. r �0 VENT CALCULATION: 1,413 / 300 = 4.11 S.F. REQ. 6 VENTS = 5.16 S.F. c ss 13Q TOTAL ROOF VENTING = 5.16 � 6Lsx6e JzWu NEW ROOF FLEX OVER ADDITION -7 BATH FLEX ROOM < AREA. ROOFING TO MATCH EXISTING. V s 4 ¢ S � NEW ROOF W � Lu NEW 6 i(?~ - J N. 4:12 - - _ OVER ADDITION _ Xze �W J -I AREA. ROOFING EX. 4:12 AN 6J(�6 _ — TO MATCH EXISTING. .�, -6Lu - - _ _ _ $,-6" I I PX I X. -4:12 I u1 W co ry li Ex. 4:12 Vk w �- V wk l I ry w / Wry Q C) I I 1 I Z wI w I 1 I is EX. 4:12 Q I n n 40JRv / 4:i�p� I \ W w ItlAX - - - - I w Ex. 4:12 _ _ 1 J LL LL �� W Ex. 2 PROPOSED 2ND FLOOR PLAN i MR, I LJJ SCALE: 1/4 = 1'-0" I ZX. 4: � ' I _ _ _ _ _ l co ILu I I E .2X. 4:1 y I I UJ W am I W r I to EX. 4:12 I EX. 4:12 I I PROPOSED ROOF PLAN SCALE: 1/8 = 1'-0" ti ti LEGEND AND NOTES Q GENERAL NOTES ADDITIONAL BLDG DEPARTMENT NOTES WALL LEGEND EXTERIOR WALL DIMENSIONS ARE TO EXTERIOR FACE OF STUD SHOWER - FOR GARAGE SEPERATION FROM THE DWELLING UNIT: SMOKE AND CARBON DETECTOR NOTES m UNLESS NOTED OTHERWISE. PROVIDE ANTI-SCALDING SHOWER AND TUB SHOWER VALVES PROVIDE SEPERATION WITH 5/8" TYPE 'X' GYPSUM BOARD - MIN 1. FIELD VERIFY THAT SMOKE DETECTORS EXISTING IN BEDROOMS EXISTING TO REMAIN PROJECT EITEL RESIDENCE INTERIOR WALL DIMENSIONS ARE TO FACE OF STUD UNLESS NOTED OTHERWISE WALL COVERING SHALL BE CEMENT PLASTER, TILE OR APPROVED EQUAL FOR GARAGE SEPERATION FROM THE ATTIC AND HALLS LEADING TO BEDROOMS PER CODE. IF NONE DRAM er KT/-r cn CONTRACTOR TO SUBMIT ALL FINISH SAMPLES TO THE ARCHITECT OR OWNER ABOVE DRAIN INLET AT SHOWERS OR TUB WITH SHOWERS. PROVIDE SEPERATION WITH 1/2" TYPE 'X' GYPSUM BOARD - MIN EXIST INSTALL SMOKE DETECTORS. I EX. WALL To BE REMOVED GAD FILE NAME EITEL L�.I PRIOR TO INSTALLATION FOR APPROVAL MATERIALS OTHER THAN STRUCTURAL ELEMENTS TO BE MOISTURE RESISTANT. ENCLOSED USABLE SPACE UNDER INTERIOR STAIRS REQUIRES 1-HOUR 2. FIELD VERIFY THAT CARBON MONOXIDE DETECTORS EXISTING IN r PLOT DATE 6-50-I5 (i.e. FLOORING, TRIM, MOULDING, WOOD SIDING, ... ETC.) WATER CLOSETS - 30" (MIN) CLR WIDTH & 24" (MIN) CLR IN FRONT FIRE RESISTIVE CONSTRUCTION ON THE ENCLOSED SIDE HALLS LEADING TO BEDROOMS PER CODE. IF NONE EXIST INSTALL T-Is FIREBLOCKING, VERTICAL OR HORIZONTAL SHALL CONFORM TO CBC 708.2. PROVIDE 22x30 ATTIC ACCESS AT ALL ATTIC AREAS WITH A INSTALL CABON MONOXIDE DETECTORS. NEW 2X4 STUD ® I6" o.c. Z� Q SAFETY GLAZING OR TEMPERED GLAZING - HEADROOM THAT EXCEEDS 30" AFTER INSTALLING INSULATION, THE INSTALLER SHALL POST IN A CONSPICUOUS REQUIRED AT SHOWER ENCLOSURES, WINDOWS AT STAIR LANDINGS, EXACT LOCATION TO BE DETERMINED BASED ON ROOF TRUSS LAYOUT 0' 1' 5' IO' Q LOCATION IN THE BUILDING A CERTIFICATE SIGNED BY THE INSTALLER AND THE GLAZING AT DOORS AND SIDELIGHTS, AND OTHER HAZARDOUS LOCATIONS. REQUIRED FLOW RATES ZL BUILDER STATING THAT THE INSTALLATION CONFORMS WITH THE REQUIREMENTS WATER CLOSETS: 1.6 gpm , OF TITLE 24, PART 6, AND THAT THE MATERIALS INSTALLED CONFORMS WITH A PERMANENT LABEL SHALL IDENTIFY EACH LIGHT OF SAFETY GALZING. SHOWER HEADS: 2.5 gpm OOD/O/�000�� THE REQUIREMENTS OF TITLE 20, CHAPTER 2. THE CERTIFICATE SHALL STATE LAUNDRY FAUCETS: 2.2 gpm Q LLTHE MANUFACTURER'S NAME AND MATERIAL IDENTIFICATION, THE INSTALLED EXTERIOR LATH: PPROVIDE TWO LAYERS OF GRADE D PAPER EGRESS BLDG DEPARTMENT NOTES LAVATORY FAUCETS: 2.0 gpm R-VALUE AND THE WEIGHT PER SQUARE FOOT. OVER ALL WOOD BASE SHEATHING KITCHEN FAUCETS: 2.2 gpm cl PROVIDE WATER RESISTANT GYPSUM BACKING BOARD AS A BASE FOR TILE OR WINDOWS AND DOORS VERIFY EMERGENCY EGRESS FROM SLEEPING ROOMS PROVIDE ULTRA FLUSH WATER CLOSETS FOR MIN 24" CLR HT, 20" CLR WIDTH, 5.7 SF MIN AREA, ALL NEW CONSTRUCTION EXISTING SHOWER HATCHING INDICATES �� o WALL PANELS FOR TUB OR SHOWER ENCLOSURES OR WATER CLOSET ALL NEW WINDOWS AND DOORS SHALL HAVE A LABEL INDICATION THE U-FACTOR AND 44" MAX TO SILL HEADS AND TOILETS MUST BE ADAPTED FOR AREAS BEING MODIFIED C COMPARTMENT WALLS AND SHGU. ALSO SHALL COMPLY WITH ENERGY DOCUMENTATION REQUIREMENTS. LOW FLOW WATER CONSUMPTION ALL NEW WINDOW MATERIAL SHALL BE VINYL, AND DUAL GLAZED LOW-E PROVIDE MINIMUM 7'-6" CEILING HEIGHT AT MEANS OF EGRESS U 32 PA2015-073 Attachment No . ZA 5 - Project Plans DIMENSIONAL OVERALL HEIGHT COMPOSITION ROOFING III HARDIE BOARD TO MATCH 1111TI1 III I II III III l� 11111 11 11 SIDING EXISTING TOP PLATE HARDIE 50ARD TOP PLA 1111 11111 11 11 IT 11 111O 1 EXIST. TOP PLATE FOR ROOF ELEMENT � W LEI O O I 1 I FLR. LN. FLR. L N TOP PLATE TOP PLA — , 04 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ NEWSlVGGO ° (n IRT SMOOTH FINIR1 O TO MATCH � V F � � d� EXISTIN6 Z O W 0 ~ ¢ °' Lq r U O ¢ d - FLR. LN. _ 14FLR. L O O O L) w COMPOSITION 5 D SIE BOARD 5 D SIE BOARD HARDIE BOARD > Lo LL 64 X w o ROOFING FRONT ELEVATION Z W m < o vi TO MATCH SCALE: 1/4 = 1'-0" o 0 O _ yr EXISTIN6 d d N LqLq NEW TOP PLATE ill ill ill IIIIIII III Ill 1111 1111 1 1 1111111111 Ill 1111 Ill 111111 11111 1 _ — — _ TOP PLA W I ;PLATE . O DIMENSIONAL O COMPOSITION ROOFING TO MATCH o _ EXISTIN6 I NEW FLR. LN. I IIIII Ill III IIIIIIIIIIII ill IIIIIIIII IIIIIIIIIIIII I ill IIIIIIIII ill I IIIIII I I iiiiiii I ill 111111 11 11 ill IIIIIIIIIIIIIIII ill I 11111 11 1 11111111111111111111 FLR. L I 1 TOP PLATE ITT J_1 L l TOP PLA o � o I ill IIIIII IN 1111 11 11 1 11 11 1 11 1111 11 111 11 11 11111111 Ill ill 11 111 11 111111111 11 ill IIIIIIIIII 11111111 11 1111 ill IIIIIIII IIII IIII ill I 111 11 1111 1111 Hill IIII IIIIII IIII ill IIIIIII iiii Hill IIIII IIII 1 - 1 LZ DIMENSIONAL COMPOSITION OFIN6 TO MATCH FLR. LN. FLR. L EXI5TIN6 NEW STUCCO HARDIE BOARD 5-4 SMOOTTO H FINI5H 51DIN6 SIDE ELEVATION H Li UJ`J EXISTIN6 SCALE: 1/4 = 1'-0" NEW TOP PLATE _ _ NEW TOP PLA l/ �NS1 WROUGHT IRON v v, RAILING ZZ DIMENSIONAL U O O COMPOSITION w O - It It FROOFIN& O Q d � TO MATCH EXISTIN6 ! , cf �o — Q � � � + �j,illl,u,III���G��i,� Ipi I. a_ W NEW FLR. LN.— — !_ r —NEW FLR. L TOP PLA 1 TOP PLA J wp o j o w I> N > DIMENSIONAL COMPOSITION ROOFING I OVERALL HEIGHT TO MATCH RXISTIN'SFLR. LN. FLR. L EN WROUGHTIRON _ RAILING BOARDNEH �IE SXTUGG FINISH 9M00THFIN]GSH 9MOOTTH F NI5H 10-2„ SIDE ELEVATION SIDING TO MATCH TO MATCH J - NEW TOP PLATE NEW TOP PLA EXISTIN6 EXISTIN6 SCALE: 1/4 = 1'-0" L_.LI L() DIMENSIONAL FOR ROOF ELLER—MSE jl� I 1�1 - HARDIE BOARD COMPOSITION SIDING OFIN6 ti TO MATCH EXISTIN6 ~ J `) LL 11 75 m N NEW FLR. LN. r II JI I NEW FLR. L PROJECT EITEL RESIDENCE � TOP PLATE _ �I TOP PLA ORAVPI Br KT/.lY cf) I - � =' GAD FILE NAME EITEL PLOT DATE 6-50-15 LL T-T-IS z p aJ Q Q � U U- FLR. LN. L-J FLR. LN CO NEW STUCCO NEW STUCCO G SMOOTH FINISH SMOOTH FINISH REAR ELEVATION A5 TO MATCH TO MATCH EXISTIN6 EXISTIN6 SCALE: 1/4 = 1'-0" U �-z