Loading...
HomeMy WebLinkAbout01 - Bay View Avenue Modification Permit - PA2015-187 o4�Ewr°Q COMMUNITY DEVELOPMENT DEPARTMENT y PLANNING DIVISION u 100 Civic Center Drive, P.O.Box 1768,Newport Beach, CA 92658-8915 (949) 644-3200 Fax: (949) 644-3229 c9treox�`P www.newportbeachca.gov CITY OF NEWPORT BEACH ZONING ADMINISTRATOR STAFF REPORT December 10, 2015 Agenda Item No. 1 SUBJECT: 20441 Bay View Avenue Modificaiton (PA2015-187) 20441 Bay View Avenue • Modification Permit No. MD2015-010 APPLICANT: Steven and Michelle Wulfestieg OWNER: Steven and Michelle Wulfestieg PLANNER: Melinda Whelan, Assistant Planner (949) 644-3221, mwhelan@newportbeachca.gov ZONING DISTRICT/GENERAL PLAN • Zone: SP-7 RSF (Santa Ana Heights Specific Plan, Residential Single Family) • General Plan: RS-D (Single-Unit Residential Detached) PROJECT SUMMARY A modification permit to allow an approximately 17-percent addition to an existing non- conforming single-family residence where the Zoning Code limits additions to 10 percent of the existing gross floor area when the required parking dimensions are not provided. The non-conforming garage currently provides 19 feet, 5 inches in width by 21-feet, 5-inches in depth where a minimum 20-foot by 20-foot dimension is required. RECOMMENDATION 1 ) Conduct a public hearing; and 2) Adopt Draft Zoning Administrator Resolution No. _ approving Modification Permit No. MD2015-010 (Attachment No. ZA 1). 1 2 20441 Bay View Avenue Modification Zoning Administrator, December 10, 2015 Page 2 DISCUSSION • The property is located in the Santa Ana Heights neighborhood and measures approximately 8,775 square feet in area and has a lot width of 65 feet, and lot depth of 135 feet. The neighborhood is developed with single-unit dwellings. • A 1,074-square-foot single-unit dwelling with an attached 447-square-foot garage is currently developed on the property, which was originally constructed in the County jurisdiction in 1953. • The applicant is proposing an addition of a laundry room and a master bathroom. The total addition proposed is approximately 263 square feet and equates to an increase of approximately 17 percent of the existing structure. The dwelling will remain one-story. • The existing interior garage dimensions of 19 feet, 5 inches wide by 21 feet, 5 inches deep were compliant with the County of Orange Zoning Code at the time of construction. The area was annexed from the County in 2003 and at the time of annexation the existing garage was compliant with the Newport Beach Zoning Code. The current Zoning Code requires a minimum 20-foot by 20-foot interior dimension for a lot that is wider than 40 feet. • Due to the change in development standards related to the minimum size of garage parking spaces required for lots 40 feet wide or more, the existing two-car garage is legal nonconforming. Additions to the existing residence are limited to 10 percent of the existing structure (Section 20.38.060.2.a and b: Nonconforming Parking — Dimensions or Type of Parking Spaces). A larger addition can be permitted with the approval of a Modification Permit (Section 20.52.050). • Given the scope of work, increasing the depth of the garage to 20 feet would result in a practical difficulty by requiring significant structural alterations to move the garage wall. • The existing garage provides two (2) useable garage spaces therefore fulfilling the intent of the Zoning Code by providing adequate parking on site. Approval of the Modification Permit allows the applicant to continue the use of the existing two-car garage, which has not proven detrimental to the occupants or neighbors of the dwelling. • The proposed addition would provide an ADA compliant laundry room and bathroom for the safety of the residents. The addition would comply with all of the required setback areas, height limits, and open volume requirement. The addition would result in a dwelling that is consistent in scale with other dwellings in the neighborhood. TmpIt:10-02-15 20441 Bay View Avenue Modification Zoning Administrator, December 10, 2015 Page 3 ENVIRONMENTAL REVIEW The project is categorically exempt under Section 15301, of the State CEQA (California Environmental Quality Act) Guidelines - Class 1 (Existing Facilities). This exemption includes additions up to 10,000 square feet where public services and utilities are available and the area is not considered environmentally sensitive. The proposed project is a 263-square-foot addition to an existing single-family residence in a developed neighborhood and is not within an environmentally sensitive area. PUBLIC NOTICE Notice of this application was published in the Daily Pilot, mailed to all owners of property within 300 feet of the boundaries of the site (excluding intervening rights-of- way and waterways), including the applicant, and posted on the subject property at least 10 days before the scheduled hearing, consistent with the provisions of the Municipal Code. Additionally, the item appeared on the agenda for this meeting, which was posted at City Hall and on the City website. APPEAL PERIOD: An appeal or call for review may be filed with the Director of Community Development within 14 days following the date of action. For additional information on filing an appeal, contact the Planning Division at (949) 644-3200. Prepared by: -1:1� "'J, Melinda Whelan Assistant Planner GBR/msw Attachments: ZA 1 Draft Resolution ZA 2 Vicinity Map ZA 3 Project Plans TmpIt:10-02-15 J Attachment No. ZA 1 Draft Resolution 5 0 RESOLUTION NO. ZA2015-0## A RESOLUTION OF THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH APPROVING MODIFICATION PERMIT NO. MD2015-010 FOR A 17-PERCENT ADDITION TO AN EXISTING NONCONFORMING SINGLE-UNIT RESIDENCE LOCATED AT 20441 BAY VIEW AVENUE (PA2015-187) THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH HEREBY FINDS AS FOLLOWS: SECTION 1. STATEMENT OF FACTS. 1. An application was filed by Steven and Michelle Wulfestieg, with respect to property located at 20441 Bay View Avenue, and legally described as Lot 25 in Tract 01501 requesting approval of a Modification Permit. 2. The applicant proposes a modification permit to allow an approximately 17-percent addition to an existing non-conforming single-family residence where the Zoning Code limits additions to 10 percent of the existing gross floor area when the required parking dimensions are not provided. The non-conforming garage currently provides 19 feet, 5 inches in width by 21 feet, 5 inches in depth, where a minimum of a 20-foot by 20-foot dimension is required. The garage dimensions were in compliance with the Zoning Code when the property was annexed from the County in 2003. 3. The subject property is located within the Single-Unit Residential Detached Zoning District and the General Plan Land Use Element category is Single-Unit Residential Detached (RS-D). 4. The subject property is located within the coastal zone. The Coastal Land Use Plan category is Single-Unit Residential Detached (RSD-C). 5. A public hearing was held on December 10, 2015, in the Corona del Mar Conference Room (Bay E-1st Floor) at 100 Civic Center Drive, Newport Beach. A notice of time, place and purpose of the meeting was given in accordance with the Newport Beach Municipal Code. Evidence, both written and oral, was presented to, and considered by, the Zoning Administrator at this meeting. SECTION 2. CALIFORNIA ENVIRONMENTAL QUALITY ACT DETERMINATION. 1. This project has been determined to be categorically exempt pursuant to Title 14 of the California Code of Regulations (Section 15301, Article 19 of Chapter 3, Guidelines for Implementation of the California Environmental Quality Act) under Class 1 (Existing Facilities) of the Guidelines for CEQA. 2. This exemption includes additions up to 10,000 square feet where public services and utilities are available and the area is not considered environmentally sensitive. The proposed project is a 263-square-foot addition to an existing single-residence in a developed neighborhood and is not within an environmentally sensitive area. SECTION 3. REQUIRED FINDINGS. In accordance with Section 20.52.050.E (Modification Permits — Required Findings) of the Newport Beach Municipal Code, the following findings and facts in support of such findings are set forth: Finding: A. The requested modification will be compatible with existing development in the neighborhood. Facts in Support of Finding: 1. The neighborhood is comprised of one- and two- story single-unit dwellings. The Modification Permit will allow expansion of the existing single-story, single-unit dwelling, which is compatible with other properties in the neighborhood. 2. The addition would increase the dwelling by 263 square feet, to provide for a new ADA compliant master bathroom and laundry room. The proposed alterations will comply with all applicable development standards, including height, setbacks, and open volume and will not intensify or alter the existing nonconforming parking. 3. The proposed addition will result in a total floor area of approximately 1,784 square feet (including the 447-square-foot garage), which is equal or less than the bulk and scale of the other single-unit dwellings within the neighborhood. 4. The existing development on the property is a single-family dwelling. As such, there is no change to the density or intensity as a result of the proposed remodel and addition. Finding: B. The granting of the modification is necessary due to the unique physical characteristic(s) of the property and/or structure, and/or characteristics of the use. Facts in Support of Finding: 1. The interior dimensions of the existing two-car garage were compliant with the County of Orange Zoning Code at the time of construction. The area was annexed from the County in 2003 and at the time of annexation the existing garage was compliant with the Newport Beach Zoning Code. However, as a result of amendments to the Zoning Code, the two-car garage is now substandard in size, and is therefore legal nonconforming. 8 2. Moving the garage wall that is not within the area of the proposed construction would be costly and significantly increase the scope of the project in order to gain 7 inches of garage width. 3. The granting of the Modification Permit is necessary to allow a reasonable addition to an existing dwelling that was constructed in compliance with garage standards in effect at the time of original construction, and that are adequate in width for the parking of two (2) vehicles. Finding: C. The granting of the modification is necessary due to practical difficulties associated with the property and that the strict application of the Zoning Code results in physical hardships that are inconsistent with the purpose and intent of the Zoning Code. Facts in Support of Finding: 1. The addition is expanding towards the rear yard of the property. Increasing the width of the garage to 20 feet would affect the side of the property and result in a practical difficulty by requiring significant structural alterations to the structure and a significant expansion in the scope of work in order to increase the depth of the garage by approximately 7 inches. 2. The existing garage provides two (2) useable garage spaces only slightly less than the required width therefore fulfilling the intent of the Zoning Code by providing adequate parking on site. Approval of the Modification Permit allows the applicant to continue using the existing two-car garage, which has not proven detrimental to the occupants or neighbors of the dwelling. Finding: D. There are no alternatives to the modification permit that could provide similar benefits to the applicant with less potential detriment to surrounding owners and occupants, the neighborhood, or to the general public. Facts in Support of Finding: 1. The alternative would require that the applicant bring the existing two-car garage into conformance by expanding the garage width. Expanding the garage width would require significant alterations to the structure well beyond the scope of the planned small addition. 2. The other alternative is to reduce the size of the addition to not more than 10 percent of the existing floor area of the structure and comply with the requirements of the Zoning Code. Given the proposal is to create an ADA bathroom and laundry room based on the existing small one-story dwelling, a redesign to reduce the size of the addition will not allow the project to meet these objectives of the applicant. 9 Finding: E. The granting of the modification would not be detrimental to public health, safety, or welfare, to the occupants of the property, nearby properties, the neighborhood, or the City, or result in a change in density or intensity that would be inconsistent with the provisions of this Zoning Code. Facts in Support of Finding: 1. The proposed one-story addition would maintain all required setbacks and will provide adequate protection for light, air, and privacy. The addition will not preclude access to the dwelling and will be consistent in scale with other dwellings in the neighborhood. 2. The existing nonconforming garage has not proven to be detrimental to the occupants of the property, nearby properties, the neighborhood, or the City and is adequate in width to park two (2) vehicles. 3. The approval of this Modification Permit is conditioned such that the applicant is required to obtain all necessary permits in accordance with the Building Code and other applicable Codes. SECTION 4. DECISION. NOW, THEREFORE, BE IT RESOLVED: 1. The Zoning Administrator of the City of Newport Beach hereby approves Modification Permit No. MD2015-010, subject to the conditions set forth in Exhibit "A,": which is attached hereto and incorporated by reference. 2. This action shall become final and effective fourteen (14) days following the date this Resolution was adopted unless within such time an appeal is filed with the Community Development Director in accordance with the provisions of Title 20 (Planning and Zoning), of the Newport Beach Municipal Code. PASSED, APPROVED, AND ADOPTED THIS 10th DAY OF AUGUSTDECEMBER, 2015. BY: Brenda Wisneski, AICP, Zoning Administrator 10 EXHIBIT "A" CONDITIONS OF APPROVAL 1. The development shall be in substantial conformance with the approved site plan, floor plans and building elevations stamped and dated with the date of this approval (except as modified by applicable conditions of approval). 2. Each parking space within the garage shall be permanently available and maintained for parking purposes. The interior dimensions (19 feet, 5 inches wide by 21 feet, 5 inches deep) shall be kept clear of obstructions including cabinets, shelving, or similar that may impact the ability to adequately park two (2) vehicles. 3. The project is subject to all applicable City ordinances, policies, and standards, unless specifically waived or modified by the conditions of approval. 4. A copy of the Resolution, including conditions of approval (Exhibit "A") shall be incorporated into the Building Division and field sets of plans prior to issuance of the building permits. 5. The applicant is required to obtain all applicable permits from the City's Building Division and Fire Department, including for the existing improvements that were constructed without the benefit of building permits. The construction plans must comply with the most recent, City-adopted version of the California Building Code. The construction plans must meet all applicable State Disabilities Access requirements. 6. Should the property be sold or otherwise come under different ownership, any future owners or assignees shall be notified of the conditions of this approval by either the current property owner or the leasing agent. 7. This approval shall expire and become void unless exercised within twenty-four (24) months from the actual date of review authority approval, except where an extension of time is approved in compliance with the provisions of Title 20 (Planning and Zoning) of the Newport Beach Municipal Code. 8. To the fullest extent permitted by law, applicant shall indemnify, defend and hold harmless City, its City Council, its boards and commissions, officials, officers, employees, and agents from and against any and all claims, demands, obligations, damages, actions, causes of action, suits, losses, judgments, fines, penalties, liabilities, costs and expenses (including without limitation, attorney's fees, disbursements and court costs) of every kind and nature whatsoever which may arise from or in any manner relate (directly or indirectly) to City's approval of the 20441 Bay View Avenue Modification including, but not limited to, MD2015-010 (PA2015-187). This indemnification shall include, but not be limited to, damages awarded against the City, if any, costs of suit, attorneys' fees, and other expenses incurred in connection with such claim, action, causes of action, suit or proceeding whether incurred by applicant, City, and/or the parties initiating or bringing such proceeding. The applicant shall indemnify the City for all of City's costs, attorneys' fees, and damages which City incurs in enforcing the indemnification provisions set forth 11 in this condition. The applicant shall pay to the City upon demand any amount owed to the City pursuant to the indemnification requirements prescribed in this condition. 12 Attachment No. ZA 2 Vicinity Map 13 14 VICINITY MAP ,` � Vis` ' ,y � /�:;. " •;, ` _� MW f J �\� ♦ �C O r. 2 Iy9/. 'f 1 �y / J' � 1 S• Modification Permit No. MD2015-010 PA2015-187 20441 Bay View Avenue s � 10 Attachment No. ZA 3 Project Plans 17 12 PA2015-187 REVISIONS BY PROJECT SCOPE OF WORK Issued for Planning Dept J.H. review, 8-5-15 Issued for Plan Check J.H. Review, 8-26-15 WULFESTIEG RESIDENCE Issued for Modification J.H. ENLARGE EXISTING MASTER BEDROOM, ADD NEW MASTER BATH, AND ADD NEW LAUNDRY ROOM TO Review, 10-5-15 EXISTING SINGLE FAMILY RESIDENCE. ENLARGE MASTER BEDROOM AND ADDITION OF MASTER BATH CODE ANALYSIS Steve & Michelle Wulfestieg AND LAUNDRY ROOM ZONING 2044 Ba view,Ave., USE CODE : SINGLE FAMILY RESIDENTIAL Newport Beach CONSTRUCTION TYPE: TYPE V-B CA 92660 FIRE SPRINKLERS: NO ARCHITECT: Year Built: 1953 20441 BAVENUE Bedrooms: 3 Jesse Hurtado ' Bathrooms: 1 Architect Lic C29989 Garage: Yes (attached) 1310 South McDonnell Avenue Los Angeles,CA 90022 Tel (323)485-4040 jesse.hurtado@gmail.com NEWPORT BEACH CA 92660 Number of Stories: 1 Square Feet: 1,074 SF It 7 Lot Size: 8,775 SF cis the clients' responsibility prior to or during is to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building ABBREVIATIONS GRAPHIC SYMBOLS LEGAL DESCRIPTION PROJECT DIRECTORY SHEET INDEX codes and methods ofWritteniionshions reasonably be aware. Wniten instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with 4 DIAMETER the work.The client will be responsible for any TI SQUARE FOOT/FEET PLYWD. PLYWOOD LEGAL DESCRIPTION: defects in construction if these procedures are & AND FUR. FLOOR P.O.C. POINT of CONNECTION 203 SPACE NUMBER x O COLUMN GRIDS OWNER / STEVE & MICHELLE WULFESTIEG A-1 TITLE SHEET not followed. AT FLUOR. FLUORESCENT PR. PAIR �� ADDRESS 20441 BAYVIEW AVE., CENTERLINE F.H. FIRE HYDRANT LOT: 25 TRACT NO: 1501 ABBREVIATED A-2 EXISTING / SITE PLAN AND ROOF PLAN PROJECT (E) EXISTING F.O.M. FACE OF MASONRY P.T. PRESSURE TREATED REVISION x Is, AROUND REVISION DESCRIPTION: LOT:25 TR#:1501 N TR 1501 BLK NEWPORT BEACH, CA 92660 A-3 DEMOLITION PLAN A.B. ANCHOR BOLT F.O.S. FACE OF STUD Q.T. QUARRY TILE - - ^^11 ABV. ABOVE F.O.C. FACE OF CONCRETE R. RISER S LATEST LOT 25 W 0 A/C AIR CONDITIONING F/S FINISH SURFACE RAD. RADIUS STRUCTURAL A-4 EXISTING AND PROPOSED FLOOR PLAN V A.C. ASPHALTIC CONCRETE F.S. FLOOR SINK R.D. ROOF DRAIN WALL SECTIONS A.D. AREA DRAIN F.S.R. FIRE SPRINKLER RISER BOND. REDWOOD 101 DOOR NUMBER _ ENGINEER A-5 EXTERIOR ELEVATIONS AND SECTION A.F.F. ABOVE FINISH FLOOR FT. FOOT/FEET 5'0 APN: O REF. REFERENCE L (Qj ALUM. ALUMINUM F.T. FIRE TREATED ARCHITECT JESUS HURTADO LEON VALENCIA & ASSOCIATES BEER. REFRIGERATOR 439-041-20 APPROX. APPROXIMATE FTG. FOOTING REINF. REINFORCED 1310 S. MCDONNELL AVE 5220 SANTA MONICA BOULEVARD FUT. FUTURE - - _ A.S.R. AUTOMATIC SPRINKLER ROOM REQ'D. REQUIRED 101 WINDOW NUMBER U GA. caucE LOS ANGELES, CA 90022 LOS ANGELES, CA 90029 �_ +-� � w BD. BOARD GALV. GALVANIZED RESIL. RESILIENT BLDG. BUILDING G.C. GENERAL CONTRACTOR RM. Roots — BUILDING SECTIONS TEL 323 485-4040 TEL 323 665-5506 - m ELK. BLOCKll G.I. GALVANIZED IRON R.H.B. RECESSED HOSE BIBB ''A4.O— V J BLKG. BLOCKING GL, GLASS R.O. ROUGH OPENING EXIT EXIT SIGN WITH jesse.hurtado@gmail.com valencia_c@earthlink.net BM. BEAM GNC. GROUND R.O.W. RIGHT OF WAY DIRECTIONAL ARROW BOT. B070M OR. GRADE R.S. RESAWN A CL O BTWN. BETWEEN GYP. GYPSUM X DETAIL REFERENCE � � H.B. HOSE BIBB W C CAMBER H.C. HOLLOW CORE S. SOUTH A2.1-1 Z C.B. CATCH BASIN S.A.T. SUSPENDED ACOUSTICAL D H INTERIOR/EXTERIOR CURRENT CODES E N F O R E C E D GENERAL NOTES PLOT PLAN CEM. CEMENT HDR. HEADER TILE 3.� — WALL ELEVATIONS W CER. CERAMIC HOW. HARDWARE Z) HT. HEIGHT S.C. SOLID CORE Z C.H.B. CONCEALED HOSE BIBB H.M. HOLLOW METAL SCHED. SCHEDULE l X WALL TYPE C . L O C.I. CAST IRON HORIZ HORIZONTAL SECT. SECTION < - C/J CEILING JOIST H.P. HIGH POINT SHT. SHEET do __ ,,, -,„ Q 1. ALL DEBRIS SHALL BE REMOVED AND LEGALLY DISPOSED OFF SITE DAILY & MAINTAINED IN CLEAN BROOM yw w� sWm O C.J. CONTROL JOINT HDWD. HARDWOOD SHTG. SHEATHING DATUM ELEVATION 9 ° *� �++ CLG. CEILING HVAC HEATING, VENTILATION & SIM. SIMILAR CONDITION AT ALL TIMES. t -syLLJ SLR. CLEAR AIR CONDITIONING sPEc. SPECIFICATION — - — _ . MATCH LINE THIS PROJECT SHALL COMPLY WITH THE FOLLOWING CODES AND C.M.U. CONCRETE MASONRY UNIT SQ. SQUARE 2. AGENCY APPROVED PLANS SHALL BE KEPT IN A PLAN RACK AND SHALL NOT BE MARKED OR USED BY ANY _ ', I.D. INSIDE DIAMETER REGULATIONS: ' ,` ;�� Y �(- } C/0 CLEANOUT I.E. INVERT ELEVATION SSK. SERVICE SINK. 100'-0" FINISH FLOOR ELEVATION WORKMEN. ALL CONSTRUCTION SETS SHALL REFLECT THE SAME LATEST INFORMATION. THE CONTRACTOR SHALL s �, z. _ w Q W,V Lu:3, C.O. CONCRETE OPENING N. NCH SS. STAINLESS STEEL ALSO MAINTAIN IN GOOD CONDITION, ONE COMPLETE SET OF PLANS WITH ALL REVISIONS, ADDENDA, AND CHANGE ' h4 W m COL. COLUMN STD. STANDARD ORDERS ON THE PREMISES AT ALL TIMES, AND IT IS TO BE UNDER THE CARE OF THE JOB SUPERINTENDENT. , �✓ INTUL. INSULATION zonal 8�yne.nn corc. CONCRETE NT. INTERIOR sTL. STEEL ST-1 EXTERIOR MATERIAL & FINISH =� CEILING HEIGHT was' v CONN. CONNECTION STOR. STORAGE X00 2013 California Building Code: Chapter 15.04 3. COORDINATE TEMPORARY UTILITIES AS NECESSARY FOR THE CONSTRUCTION WITH THE OWNER. JT. JOINT ,! u - s O CONSTR. CONSTRUCTION STRUCT. STRUCTURAL REFER TO SHEET A3.0-00 � wa •, r � N FOR FINISH SCHEDULE 4. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND COORDINATE WITH ALL TRADES. NOTIFY THE ARCHITECT & �s "°" """'"` CONT. CONTINUOUS IAM. LAMINATED S.O.V. SHUT OFF VALVE 2013 California Residential Code: Chapter 15.05 ` CONTR. CONTRACTOR LAV. LAVATORY SYM. SYMMETRICAL p IMMEDIATELY OF ANY DISCREPANCIES OR CONFLICT PRIOR TO PROCEEDING WITH ANY WORK. UNLESS OTHERWISE • s , CTSK COUNTERSUNK Lr. LIGHT T. TREAD NOTED OR INDICATED, ALL DIMENSIONS ON THE PLANS SHALL BE FROM CENTERLINE OF COLUMN, FACE OF C.Y. CUBIC YARD MAX. MAXIMUM T.B. TOP OF BEAM CONCRETE, FACE OF MASONRY, OR CENTERLINE OF FRAMING EXCEPT AT BUILDING PERIMETERS WHERE IT IS DBL. DOUBLE M.B. MACHINE BOLT T.O.C. TOP OF CURB KEY NOTE 2013 California Electrical Code: Chapter 15.06 OUTSIDE OF FRAMING. w'a'"s, DEPT. DEPARTMENT MECH. MECHANICALTEL. TELEPHONE DEF. DETAIL MET. METAL 5. THE CONTRACTOR SHALL OBTAIN ALL PERMITS, LICENSES, AND INSPECTIONS FROM THE CITY OF NEWPORT BEACH T&G TONGUE AND GROOVE 2013 California Mechanical Code: Cha ter 15.07 D.F. DRINKING FOUNTAIN MFR. MANUFACTURER THK. THICK p TO COMPLETE THE WORK. =sa ,`` "IN xn°al DIA. DIAMETER M.H. MANHOLE FE FIRE EXTINGUISHER SECURED IN AN T.J. TRUSS JOIST DIM. DIMENSION MIN. MINIMUM APPROVED CABINET, MIN. 2A:10BC 6. THE PROTECTION OF ALL STRUCTURES AND UTILITIES ON THE SITE IS THE RESPONSIBILITY OF CONTRACTOR. 3 5 T.Q.P. TOP OF PARAPET 2013 California Plumbing Code: Chapter 15.08 w T e F y R F,.,d^d DN DOWN MISC. MISCELLANEOUS T.O.T. TOP OF SHEATHING d DR DOOR M.O. MASONRY OPENING 7. INTENT OF THE DOCUMENTS :- 1 ' ' T.O.W. TOP OF WALL " _ Lij DS DOWNSPOUT MTD. MOUNTED TYP. TYPICAL 2013 California Green Building Standards Code: Chapter 15.11 THE EXTENT OF THE WORK IS ONLY INDICATED GENERALLY ON THE DRAWINGS AND SHALL NOT BE CONSIDERED '°°""°"d ` DWG. DRAWING MTT MAIN TELEPHONE E EAST TERMINAL U.O.N. UNLESS OTHERWISE NOTED MATERIAL SYMBOLS AS THE COMPLETE SCOPE CONDITIONS INDICATED ARE BASED ON LIMITED SURVEYS OF EXISTING CONDITIONS a �, AND EXISTING DRAWINGS. �/� EA. EACH MUL. MULLION E.J. EXPANSION JOINT N. NORTH VERT. VERTICAL 2013 California Historical Building Code: Chapter 15.13 ,,I,I� vn 8. IT IS THE INTENT OF THESE CONSTRUCTION DOCUMENTS TO INCLUDE ITEMS AND COMPONENTS OF THE PROPER F "' ELECT. ELECTRICAL N.I.C. NOT IN CONTRACT V,C.T. VINYL COMPOSITION TILE - - y No. NUMBER ,,'� I-aaM°n 41md V.T.R. VENT THROUGH ROOF EXECUTION OF THE WORK, AND THE PROVISIONS FOR A COMPLETE AND FUNCTIONAL FACILITY. IN THAT REGARD �% a°�� W EL ELEVATION � E ,;�' E.O.S. EDGE OF SLAB NOM. NOMINAL 2013 California Existing Building Code: Chapter 15.14 ALL APPURTENANT AND ACCESSORY ITEMS AND COMPONENTS REQUIRED FOR CONSTRUCTION OF COMPLETE AND 5 i +-. W. WEST °`� „n,�` -�NOR�TH J E.P. ELECTRICAL PANEL N.T.S. NOT TO SCALE W/ WITH FUNCTIONAL SYSTEMS WITHIN THE CONSTRUCTION SHALL BE PROVIDED WHETHER SPECIFICALLY IDENTIFIED IN d EQ. EQUAL O.A. OVERALL W.C. WATER CLOSET 2013 California Energy Code 15.17 THESE CONSTRUCTION DOCUMENTS OR NOT. EQUIP. EQUIPMENT O.C. ON CENTER WD. WOOD EARTH GYPSUM BOARD PROJECT LOCATION E.W.IEACH war O.D. OUTSIDE DIAMETER W.H. WATER HEATER 9. IT SHALL BE THE RESPONSIBILITY OF HE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES, WHETHER SHOWN EXIST. EXISTING SHOWN IN SECTION SHOWN IN SECTION OFD. OVERFLOW DRAIN W/0 WITHOUT HEREON OR NOT, AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSE OF EXT. EXTERIOR 6i OPG. OPENING W.R. WATER RESISTANT D REPAIR OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGED BY OPERATIONS IN CONJUNCTION WITH FDN FOUNDATION OPP. OPPOSITE W.W.F. WELDED WIRE FABRIC CAST-IN-PLACE CONCRETE PLASTIC LAMINATE PLAN OR SECTION THE EXECUTION OF THE WORK, SHOWN IN SECTION F.D. FLOOR DRAIN PART'N PARTITION G7 F.F. FINISH FLOOR P.L. PROPERTY LINE 10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF HIS WORK AND MATERIAL AND z FIN. FINISH PLAT. PLASTER STONE TILE CLADDING WOOD BLOCKING CONTINUOUS EQUIPMENT WHILE JOB IS IN PROGRESS AND UNTIL JOB IS COMPLETED. � FIXT. FIXTURE PLBG. PLUMBING PLAN OR SECTION SHOWN IN SECTION 1. CONTRACTOR SHALL REFER TO AND CROSS-CHECK DETAILS, DIMENSIONS, NOTES AND ALL REQUIREMENTS SHOWN o RIGID ROOF INSULATION ON THE ARCHITECTURAL DRAWINGS WITH RELATED REQUIREMENTS ON THE STRUCTURAL, MECHANICAL, ELECTRICAL OR SAFING, PLAN OR SECTION FINISHED WOOD DRAWINGS. SECTION OR ELEVATION CHECKED BY: J H STONE: TAs NOTED, MARBLE, ONISHED wooD DEFERRED PERMITS 2. PROVIDE ALL NECESSARY BLOCKING, BACKING, SLEEVES, AND FRAMING FOR A COMPLETE SYSTEM, 5-1-2015 SECTION OR ELEVATION 3 ALL MATERIALS SHALL BE NEW, UNLESS NOTED OTHERWISE. METAL: TYPE AS NOTED PLAN OR SECTION 14. THE CONTRACTOR SHALL PROVIDE ALL BARRICADES, WARNING SIGNS, AND PROTECTIVE DEVICES AND SHALL TAKE SPRAYED FIREPROOFING SHOWN IN SECTION ALL PRECAUTIONARY MEASURES TO PROTECT ALL PERSONAL, PROPERTY, AND WORK SITE. METAL: ROLLED SHAPES OR PLAN OR SECTION D SPRAYED FIREPROOFING THE FOLLOWING WORK HAS BEEN DONE UNDER SEPARATE PERMITS: SHOWN IN SECTION t. ACOUSTICAL TILE SHOWN IN SECTION BATT INSULATION: THERMAL DRAWN BY: GG OR ACOUSTICAL, LION SHEET NO.: RESILIENT FLOORING: VCT, SLATS SHEET VINYL, LION SECTION PLASTER ON METAL LATH CMU SHOWN IN SECTION SECTION A 1 LANDSCAPE AREA JOB NO. ?9 PA2015-187 REVISIONS BY Issued for Planning Dept J.H. review, 8-5-15 Issued for Plan Check J.H. Review, 8-26-15 Issued for Modification J.H. Review, 10-5-15 ( E) CMU BLOCK WALL ( E) CMU BLOCK WALL OWNER: - - - - - - - - - - - - - - - - - - - - - - PROP. LINE 65.0' PROP. LINE 65.0' Steve & Michelle Wulfestieg Y 20441 Bayview Ave., Newport Beach, z w CA 92660 0 I ARCHITECT: LO Jesse LO } Hurtado Q Archit ct9969 1310 South McDonnell Avenue 'I 'I Los Angeles, CA 90022 'I 'I Tel (323)485-4040 jesse.hurtado@gmail.com It is the clients' responsibility prior to or during O construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor O O thoroughly knowledgeable with the building 'I C I (.0 codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work.The client will be responsible for any defects in construction if these procedures are p not followed. LC Cl) I PROJECT W J Z A OB Ja A ( E) PLANTED 3Ym Y U � + Of `0N O( E) LOT SIZE: ( PLANTED0 8,775 S.F. m1 -O8 28'-1" 13'-2" -9 } U loe ( CONIC (q PLANTED C D LU Y/ m STEPPING I ST}EPPING C 1 — (q GUTTER (M GUTTER S 1 ONES — v S 1 ON S (D Q 0 o I o � >a J W k o zs zs Z Z zs 06 z Ld U Q 0 - - - - - - - - - - — 3 _ 3 — q CONCRETE PAD ? X11 ( E) CON RETE P D (n O O I 'I O vUi PAD CO CRETE O - Q (q 4:12 SLOPE J } O W Uj LL ( E) SINGLE Q O WELL m o FAMILY 2 g w M 0�-0- 0 - RESIDENCE - -o�- U 2 - - - CD O1 ,074 S.F. v O O m Y YI O Y O G �' cls I G c � I Q U (q RIDGE U O w � AS V O ^AJ^TR. TR. d (E) RIDGE b 00 GARAGE O 81- „ 1-01 'i ( E) A�.�O— c E) A �O uU (q SID= AR L ( SDEYARD 447 S.F. /� /� J SET K a SE BACK ON CNC. ON I�ONI� L � a I PAD PAD I ® Q 3 _ -� ;�- - - O ( � PORCH j - - - -- L O ( � PORCH ® Q 0- -I- - - - o o ( � W/M ENTRY ( E) W/M ENTRY ILL Oq WALL BEL w - - - �, - -� -( -P-LANT-ED- - 4 - -� -PLAN IL a- O t o I (q CONC.WALKWAY I - 8=0I' ( E) CONC. WALKWAY 9I-0" 8'.01' ( E) CONC. WALKWAY 91-01, LU O M 0 ( SID�YA D ( E) IEYAR ( SID YARD ( E) IEYAR 0 E DGND DRIVEWAY SETBACK 48'-0" STACK SETBACK 48'-0" SETBACK a0 (q PLANTED (E) PLANTED ld la a '-0"MIN. '-0"MIN. z S DEYA D �� ( � PLANTED U S DEYA D ( � PLANTED Y CO ~ Q TBAC m TBAC � 0 m w z X z of Z coQ ( E) PLANTED ��� Cl) z J ( E) PLANTED ��� o z O 0 � d CHECKED BY: J H Z � 9� LL_ LL LL_ 5-1-2015 o C) 0 N } ( E) CONC. DRIVEWAY ( E) CONC. DRIVEWAY z 0 OLL PROP. LINE 65.0' PROP. LINE 65.0' DRAWN BY: GG SHEET NO.: ROOF PLANti PROPOSED SITE PLAN o�y EXISTING SITE PLAN ��Ty 3 1/8"=1'-0" ® 1/8"=1'-0" ® 1/8"=1'-0" ® A2 0 CD rn JOB NO. 20 PA2015-187 REVISIONS BY Issued for Planning Dept J.H. review, 8-5-15 Issued for Plan Check J.H. Review, 8-26-15 I Issued for Modification J.H. Review, 10-5-15 ( E) PLANTED I OWNER: 8'-0" 15'-0" 28'-1" 28'-2" Steve & Michelle 13'-2" Wulfestieg 10'-8" 1 4'-10" 11'-9" NEW ADDITION leI ( E) CONC. SLAB ON Gf�ADE 20441 Bayview Ave., ( E) EL. TR. TO REMAIN Newport Beach, ---------------------------------- I CA 92660 ARCHITECT: I I J J ( E) MASTER BEDROOM Jesse Hurtado ( E) BEDROOM U U �,, I Architect LicC29989 I�I 1310 South McDonnell Avenue Los O N III Tel (323) 485 ngeles, CA 404022 REMOVE ( E) WALL, I -' i I i� I jesse.hurtado@gmail.com LL DOOR AND WINDOW j i It is the clients' responsibility prior to or during rI7 construction to notify the architect in writing of O ----- _ any perceived errors or omissions in the plans I I _ and specifications of which a contractor O thoroughly knowledgeable with the building L O codes and methods of construction should II -=1-______________ N I reasonably be aware. Written instructions addressing such perceived errors or omissions 0--REMOVE ( E) STEPS shall be received from the architect prior to the client or clients subcontractors proceeding with O ° the work.The client will be responsible for any J ( E) BATHROOM DNi �I defects in construction if these procedures are not followed. I � PROJECT O ( E) TUB Q - --jo U U ( E) OFFICES FLIP U N iii III ( E) DOOR O C'0 ( �) LIGHT mil ��� ,�;� \ � Q M ELL YU ( ( � E:1u( ESHELVES —REMOVE ( E) WATER < HEATER <® ( E) KITCHEN O( E) CONC w U 0- 0 O STE PING OY m LL 0 ( w m STO ES o @ m ^, �0 Z U ( ) GAS[ UOMTR. ( E) LIVING ROOM w �OCON �O (CEOo N lOPAD ( E) 2-CAR GARAGE wQ — } ( CONC. SLAB ON GRADE FLOOR) m CO ( E) ENTRY DOOR S N ±0.00 ( E) DINING AREA -7" I I — I I I Iz ( E) MAIN ( E) PORCH WITH RAILING J WATER INLET DN ( E) ROLL-UP DOOR ( E) PLANTED ( E) PLANTED o ( E) CONC. WALKWAY 27'-0" ILL. ( E) WD. fENCE Z AND GATE ( E) WD. O FENCE AND H 9'-10" 17'-10" 20'-4" GATE J 8' 0" O oii ( E) SIDEYARD ( E) S?DEYARD W SETBA K 48'-0" SE BACK7r CD D z of co ( E) PLANTED p c-, i I CHECKED BY: J H Z CQ� m ;Z 5-1-2015 LU u' I i � � �q �k � 0- 9Y ( E) CONC. DRIVEWAY M ZO Z 0- ( E) PLANTED Of O LL U 1 DRAWN BY: GG SHEET NO.: LEGEND: RTti ------ EXISTING WALL TO BE DEMOLISHED DEMOLITION FLOOR PLAN 0 ( E) WALL TO REMAIN ® ( N) WALLS JOB NO. PA2015-187 REVISIONS BY Issued for Planning Dept J.H. review, 8-5-15 Issued for Plan Check J.H. Review, 8-26-15 Issued for Modification J.H. ( E) PLANTED ( E) PLANTED Review, 10-5-15 A B C D A B C D I 1 I 1 I A 5 A 5 I OWNER: 8'-0" , 28.1 28'-1" 19'-11" 13'-2" ' Steve & Michelle 10-8 4 -10 11 -9 10-8 4-10 111-9.. NEW ADDITION I Wulfestieg ( E) EL. TR. ( E) EL. TR.lo 20441 Ba view Ave., 771 1eel CA 92660 each, 2 ( E) MASTER BEDROOM o M o 2 ARCHITECT: U U ( E) BEDROOM ( E) MASTERBEDROOM A-5 U U � HO ER ir> Jesse Hurtado w w ( � BEDROOM 2i 2i A-5 I Architect ( N) POCKET a czssss 0 3 N 3 0 3 v N DOOR ( � 3 j Los Angeles CA 90021310 South 1Z Avenue e e e e e e e e e e e e e _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ — e — — — — — — — — — - e e e e Tel (323) do@g ai e e e e e e e e e e e _MAS7= e e e e jesse.hurtado@gmail.com A-5 e e � I � BATH ( N)/ I A_5 Z ( E) CONC. PATIO - Q I It is the clients' responsibility prior to or during O O -01 LET I— 1 construction to notify the architect in writing of Ir O O C O ( N) CLOSET • O < O and specifications of which a contractor _ — = any perceived errors or omissions in the plans -' L -------------- ® N Q N I thoroughly knowledgeable with the building N > codes and methods of construction should W reasonably be aware. Written instructions o DN J �� z I addressing such perceived errors t missions shall be received from the architect prior to the �_ ( N DN~ I client or clients subcontractors proceeding with ( E) BATHROOM ( E) BATHROOM ( N) LAUNDRY the work.The client will be responsible for any O defects in construction if these procedures are O00 I i O � N not followed. to � O ( E) TUB Q ( E) TUB Q PROJECT U Q ( E) OFFICES 3" U Q ( E) OFFICES I � U I _ � O AQ_ IGHT q ( ) IGHT CLOSET (W D 6-g O °' C �-2LL r– ( REF – – – – 2 °' LL – ( ---REF – – – – L UI I I �''� I a (� 1 ® I I J ( E) SHELVES - - ( E) SHELVES N 1 HOUR ' '— U Q W/ Q 'I® TANKLESS WATER D RA D WALL Q Q 1 _ m mar Y ( E) I CONC ( E) KITCHEN w J Y ( E) 'LONG ( � KITCHEN HEATER 3-2 Y I ST�PPING ° ° STE�PING ° UO I N a STONES ? STO ES ® co 1 L.L Z LO Wd g I g I 19'-5" w ( ) GAS ( ) GAS i z MTR. MTR. N r O LLJ � O Ll N 1 O W U ( E) LIVING ROOM v co ( E) A/ ON O z M Q ( E) ON CON PAD 111I ( E) LIVING ROOM CONS PAD Q w o I O w ( E) 2 CAR GARAGE N �' J a ( E) 2-CAR GARAGE C) I `� > ( CONC. SLAB ON GRADE FL OR) 0 ( CONC. SLAB ON GRADE FLOOR) 1 W VJ m m C0 ( E) ENTRY DOOR I POP'S ±0.00 ±0.00 I LJJ o IL ( E) DINING AREA ( E) DINING AREA I 03 - - - - - 7" - - - - - - - - 7., - - - I I I ( E) MAIN LDN ( E) PORCH WITHRAILING ( E) MAIN ( E) PORCH WITH RAILING 0 LF WATER INLET ( E) ROLL-UP DOOR WATER INLET DN ( E) ROLL-UP DOOR ; CO 04 —� – �(E)–PLAN-TE-D (-E) PLANT E� – – – – – – – – –I I I 4 � _ (� -PLANTER (-E) PLAN-T-EB- – I O Q I OZ J ( E) CONC. WALKWAY ( E) CONC. WALKWAY IL CL I I I 27'-0" 0 O ( E) WD ENCE /( E) WD.fENCE AND GATE AND GATE FE WD. ' Q FENCE AND � J 9'-10" 17'-10" 20'-4" 9'-10" 17'-10" 20'-4" GATE I Z W 8'-0" 8'-0.. . 0" ' �j ( Q SIDEYARD ( SI ( E) SIDE ( E)( E) S DEYARD w x SETBA K 48'-0" SE 11 SETBA K 48'-0" SE BACK W 10 of I I I I- a co ( E) PLANTED M ( E) PLANTED 'm ILLI CO UQ w CO UQ i w CHECKED BY: J H J �CtiC m Of � 5-1-2015 LU '/� W F '"/� W 10 '9�L" O CO V 10 ���// O co W 10 I � 1 � 10 ry ' ~ � 1 a ( E) PLANTED ( E) CONC. DRIVEWAY M ZO 0- 9Y ( E) CONC. DRIVEWAY c`i 0 z a (if ( ( E) PLANTED � O LL C LL U I I I LEGEND: DRAWN BY: GG SHEET NO.: EXISTING FLOOR PLAN do 0 ( E) WALL TO REMAIN do 2 ®�Tti ® ( N) WALLS PROPOSED FLOOR PLAN ®�Tti A4 JOB NO. 22 PA2015-187 REVISIONS BY Issued for Planning Dept J.H. review, 8-5-15 Issued for Plan Check J.H. NOTES: Review, 8-26-15 Issued for Modification J.H. Review, 10-5-15 1. PROTECTION OF WOOD AND WOOD BASED PRODUCTS FROM DECAY SHALL BE PROVIDED IN THE LOCATIONS SPECIFIED PER SECTION R317.1 BY THE USE OF NATURALLY DURABLE WOOD OR WOOD THAT IS PRESERVATIVE-TREATED IN ACCORDANCE WITH AWPA U1 FOR THE SPECIES, PRODUCT, PRESERVATIVE AND END 4 3 2 1 USE. PRESERVATIVES SHALL BE LISTED IN SECTION 4 OF AWPA U1. 2. PROVIDE ANTI-GRAFFITI FINISH WITHIN THE FIRST 9 FEET MEASURED FROM GRADE, AT OWNER: EXTERIOR WALLS AND DOORS. ( N) ASPHALT SHINGLE ROOFING, CLASS A TO MATCH EXISTING ASPHALT SHINGLES Steve & Michelle 3. DAMP PROOFING: I WUIfeStleg ( N) 7/8" STUCCO OVER CORROSION RESISTANT EXPANDED METAL OVER 2 LAYERS OF ( E) ASPHALT SHIN LE ROOFING 12 20441 Bayview Ave., GRADE-D BUILDING PAPER BY G.M. CRAFT ICC# ESR-2376 OR APPROVED EQUAL. COLOR Newport Beach, OF STUCCO TO BE SELECTED BY OWNER. 12 4 CA 92660 TOP OF PLATE ARCHITECT: — — — — — — — — — — — — — — — — — — — WINDOW LINE Jesse Hurtado - Architect LICC29969 1 1310 South McDonnell Avenue Los Angeles, CA 90022 \ Tel (323)485-4040 jesse.hurtado@gmail.com O It is the clients' responsibility prior to or during � construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor / thoroughly knowledgeable with the building codes and methods of construction should FINISH FLOOR reasonably be aware. written instructions — addressing such perceived errors or omissions GRADE LEVEL shall be received from the architect prior to the client or clients subcontractors proceeding with the work.The client will be responsible for any defects in construction if these procedures are not followed. ( N) 7/8" TUCCO OVE CORROSION RESISTANT EXPANDED METAL LAT OVER 2 LAYERS OF GRADE PROJECT BUILDING PAPER BY G.Y. CRAFT ICC# ESR-2376 OR APPROVED EQUAL OYER PLYWOOD OR OSB, SHEATHING, TYP. SEE STRUCTURAL FOR ADDITIONAL INFORMATION, CO OR OF STUCCO TO BE o SELECTED BY OWNER. YP. U N rn 4 0 w SIJ � � O 0- NORTH EXTERIOR ELEVATION 06 Z T�� 2 1/4"=1'-0" n �i O LLJ> Q O w `~ W � m � o D C B A D C B A > N ( N) ASPHALT SHINGLE ROOFING, CLASS ATO I ( N) ASPHALT SHINGLE ROOFING, CLASS ATO MATCH EXISTING ASPHALT SHINGLES ( E) ASP�IALT SHINGLE ROOFING ( E) AS HALT SHINGLE ROOFING MATCH EXISTING ASPHALT SHINGLES Z Q 12Z 12 12 4 12 4 O O 4 � 4F LJ TOP OF PLATE TOP OF PLATE I j CO — — WINDOW LINE 0 W Li 1 W MAST BATH MASTER BEDROOM a BEDROOM of FINISH FLOOR FINISH FLOOR CHECKED BY: J H GRADE LEVEL 0 Q GRADE LEVEL 5-1-2015 I I I I I I I ( N) 7/8" STUCCO OVER CORROSION RESISTANT EXPANDED METAL LATH OVER 2 LAYERS F GRADE-D 2X WOOD FRAMI G, SEE STRUCTURAL CRAWL SPACE BUILDINGPAPER BY G.M. CRAFT ICC# ESR-2376 OR APPROVED EQUAL OVER PLYWOOD OR SB, DRAWINGS FOR DDITIONAL SHEATHING, TYP. SEE STRUCTURAL FOR ADDITIONAL INFORMATION, COLOR OF STUCCO T BE I INFORMATION, TYP. SELECTED BY OWNER. TYP. I DRAWN BY: GG SHEET NO.: A�5 3 BUILDING SECTION WEST EXTERIOR ELEVATION JOB NO. 23 Zoning Adminisrator-December 10,2015 Item No. 1a-Additional Materials Received 20441 Bay View Avenue Modification(PA2015-187) INLAND ENERGY, INC. 3501 Jamboree Road SOUthTower Suite 606 Newport Beach, CA 92660 Ph 949 856-2200/Fax 949 856-2313 www.InlandEnergy.Com Wm. Buck Johns. President /